The Series 85 Filter/Separator is a two stage unit. The first stage employs

PEACH PCHG filter-coalescing elements.These elements remove the solids contamination and
coalesce entrained liquid droplets. The coalesced liquid is then removed in the second stage
vane mist eliminator and collected in the liquid sump to be drained. These units are capable of
removing solids and liquid particles
F F F G one micron and larger when
Drains & Vents
45 operated within 10% and 100%
Drains & Vents
45
45
45 45
45
45 45
INLET
of their rated capacity.
OUTLET INLET
HSLD
OUTLET

HSLD
Vent Guage Glass Vent Guage Glass
4-13/16" 4-13/16"
Diameter Holes Pressure Guage Diameter Holes Pressure Guage

Vent 1/2" Vent 1/2"


CPLG CPLG
H H

Vent 1" GA.GL.


CPLG (F.S.) 1/2" CPLG

INLET Vent 1" GA.GL.


12" CPLG (F.S.) 1/2" CPLG SERIES 85 & SERIES 90
INLET MATERIALS OF CONSTRUCTION
GA.GL. 12"
PR.GA.
1/2" CPLG Vessel ______________ Carbon Steel
1/2" CPLG Drain 1" A A
CPLG (F.S.)
OUTLET
PR.GA.
1/2" CPLG
Drain 1"
CPLG (F.S.)
Cover ______________Carbon Steel
OUTLET
B O.D. D Gasket __________________Buna-N
D Vent 1" B
CPLG (F.S.) O.D.
Vent 1" Element Support ______Carbon Steel
12"
CPLG (F.S.)
HSLD 1" C C
CPLG GA.GL. 12" 12" HSLD 1" GA.GL. 12"
Paint ________________Grey Primer
1/2" CPLG CPLG
1/2" CPLG

85
Vane ________________Carbon Steel
2" 2" 2" 5"

E Drain 1" E Drain 1"


CPLG (F.S.) CPLG (F.S.)
BOLT CIRCLE BOLT CIRCLE

SERIES 85 DIMENSIONS

Model O.D A B C D E F G H INLET & OUTLET


85-1-PCHG12 6 5/8 54 3/4 44 1/2 24 36 1/8 9 1/8 9 1/4 14 2 R.F. 150# Flange
85-1-PCHG24 6 5/8 69 3/4 44 1/2 24 39 1/8 9 1/8 9 1/4 26 2 R.F. 150# Flange
85-1-PCHG36 6 5/8 78 3/4 44 1/2 24 36 1/8 9 1/8 9 1/4 38 2 R.F. 150# Flange
85-2-PCHG36 8 5/8 85 3/4 51 1/2 30 43 1/8 11 1/8 10 1/4 15 38 3 R.F. 150# Flange
85-3-PCHG36 10 3/4 92 1/8 56 1/2 33 48 1/8 13 1/4 11 3/8 18 38 3 R.F. 150# Flange
Notes: 1. Changes to standard units, including different inlet and outlet sizes, inspection opening, or special connections can be furnished at
slight additional cost. Consult factory for price and delivery.
2. Filters are of welded construction for a safe working pressure of 275 P.S.I. at 100 F and are ASME, Div. 1, Section VIII code stamped.
3. All dimensions are in inches.
4. Models with 1/8 corrosion allowance are available.

0 Drain

315 45
Equalizer G
INLET OUTLET
270 90
HSLD GA.GL.

The Series 85 Offshore is designed


Vent
225

G
PR.GA

H
135
Element Removal

specifically for the offshore industry to remove


J Required for

Vent

liquid and solid contaminant particles, such as


hydrocarbon liquids, dirt, rust and pipeline scale
from natural gas fuel in low flow applications. Units Equalizer

feature flanged connections, blind flange closures

85
INLET
GA.GL.
O.D.Dia.

and 3-coat marine paint systems. Drain


GA.GL.

A PR.GA. PR.GA.
OFFSHORE OUTLET
Equalizer
SERIES 85 OFFSHORE DIMENSIONS B
Inlet NPT Vent GA. NPT D
HL.SD.
Model O.D Outlet & PR.GA. GL. Drain HSLD Equalizer A B C D E F G H J GA.GL.
C
85-1-36-6-275 (OFF) 6 5/8 2 1/2 1 1 1 1 82 3/4 47 1/2 27 39 1/4 5 9 1/8 9 1/4 9 1/4 38 HL.SD.
GA.GL.
85-1-36-8-275 (OFF) 8 5/8 3* 1/2 1 1 1 1 86 3/4 54 1/2 33 42 3/8 5 11 1/8 10 1/4 15 38
85-1-36-10-275 (OFF) 10 3/4 3* 1/2 1 1 1 1 96 1/8 59 1/2 36 48 1/4 5 13 1/4 11 3/8 18 38 E
2"
* Outlet to have a reducer to listed size. F Drain

CL(4) 13/16" BOLT HOLES


LOCATED AT 45 OFF VESSEL CL
F F

The Series 90 is designed for filtering dry gas or air


45
Drains
45
streams.These units are extremely useful in removing desiccant INLET
45 45
OUTLET

fines, pipe scale and other solid contaminants one micron and Vent

larger. Employing single stage filtration and capable of 4-13/16"


Diameter Holes Pressure Guage

utilizing a number of different element styles, it

Element Removal
G

90
Air Vent Valve

Required for
1/2"CPLG
is a versatile performer. Swing Bolt

SERIES 90 DIMENSIONS

Model O.D A B C D E F G H INLET & OUTLET O.D.


90-1-PCHG12 6 5/8 26 15 3/4 4 7 3/4 9 1/8 9 1/4 14 1 5/8 2 R.F. 150# Flange
A
90-1-PCHG24 6 5/8 41 15 3/4 4 7 3/4 9 1/8 9 1/4 26 1 5/8 2 R.F. 150# Flange
90-1-PCHG36 6 5/8 50 15 3/4 4 7 3/4 9 1/8 9 1/4 38 1 5/8 2 R.F. 150# Flange PR. GL.1/2" CPLG
INLET
90-2-PCHG36 8 5/8 50 15 3/4 4 7 3/4 11 1/8 10 1/4 38 2 3/8 3 R.F. 150# Flange
90-3-PCHG36 10 3/4 50 3/4 15 3/4 4 5/8 7 3/4 13 1/4 11 3/8 38 3 5/8 3 R.F. 150# Flange
Drain 1" CPLG (F.S.)
Notes: 1. Standard units as shown are stock items.
Anchor PR. GL.1/2" CPLG
2. Changes to standard units, including different inlet and outlet sizes, inspection opening, or special connections can be furnished at B
Bolt Lug
slight additional cost. Consult factory for price and delivery. OUTLET
3. Filters are of welded construction for a safe working pressure of 275 P.S.I. at 100 F and are ASME, Div. 1, Section VIII code stamped. H D
4. All dimensions are in inches. 2"
C
5. No corrosion allowance. E Drain 1"
CPLG (F.S.)

SERIES 85 & 90 ARE IDEAL FOR:


Fuel gas for large engines
Fuel gas for large boilers
Fuel gas for direct fired heaters 200

Supply gas for automatic control


equipment 100
90
OPERATING PRESSURE (PSIA)

80
Protection of valves and meters 70
60
_Desiccant bed outlet 50

36

36
36
G24

G36
1-P G24
2

6
2

G3
G1

G3
G1

HG

HG
HG
_Contactor inlet 40

CH
CH
CH

CH

CH

CH
CH

-PC

-PC
-PC
1-P

1-P

2-P
1-P

1-P

1-P
30

85-3

90-3
90-2
85-
90-

85-

85-
85-

90-

90-

20

C O N V E R S I O N C H A R T 10

100,000

200,000
10,000

20,000

30,000

40,000
50,000
60,000
70,000
80,000
90,000
1,000

8,000
6,000
5,000

7,000
3,000
2,000

4,000

9,000

1.50
MAXIMUM FLOW RATE (SCFH of 0.65 SP. GR. at 14.7 PSIA and 60 F)

1.40

1. If vapor phase is other than natural gas of 0.65 specific gravity at 60 F and
1.30
14.7 PSIA, correct to these conditions using the PECO Conversion Chart on
top left hand corner of this sheet as follows:
SPECIFIC GRAVITY, AIR - 1.00

1.00
CORRECTION FACTORS

1.20 Find the maximum operating temperature on the horizontal scale.


.90 Follow temperature line vertically until it intersects with the specific
gravity line. The correction factor is then found horizontally to the right
.80 1.10
of the intersection.
2. Multiply the flow rate (SCFH) by the correction factor.
.70
1.00 3. Determine PECO Filter-Sep or Filter required by entering sizing chart at left at
minimum operating pressure. Move to right to intersection with the corrected
.60
maximum gas flow line.The PECO Filter-Sep or Filter required is shown by the
.90
slanted line to the right of the intersection of the operating pressure and
.50
corrected maximum gas flow lines.The Sizing is based upon a maximum
40 80 120 160 200 240 280
.80 pressure drop of 60 water column across the entire unit.
GAS FLOWING TEMPERATURES, F
8 1/2"

6 1/4"

Element Removal
12" Required for Gruva Grip
Closure
The Series 88 is designed for general
process gas applications where a compact, high
pressure vessel is required.
4 1/2"
19 3/8" SERIES 88
Element MATERIALS OF CONSTRUCTION
3/4" 3000#
CPLG Outlet
Vessel ______________ Carbon Steel

20,000
4 7/8"

3/4" 3000# CPLG


Inlet
1/4" 3000# CPLG
Blowdown
88 Cover ______________Carbon Steel
Gasket __________________Buna-N
Blowdown Plug ________Carbon Steel
Element Support ______Carbon Steel
Couplings ______________300# NPT
Paint ________________Grey Primer
at 14.7 PSIA, 60 F .65 S.G> NATURAL GAS

10
9 88 Conversion Chart
MAXIMUM FLOW RATE SCF/H

8
7
6 1.50
5

4
1.40
3

2 SPECIFIC GRAVITY, AIR - 1.00 1.30

1.00

CORRECTION FACTORS
1.20
.90
1000
10 2 3 4 5 6 7 8 9 100 2 3 4 5 6 700
.80 1.10
OPERATING PRESSURE (PSIA)

.70
1.00

.60

.90

.50

.80
40 80 120 160 200 240 280
GAS FLOWING TEMPERATURES, F

e-mail: vessels @ perryequipment.com


web site: www.perryequipment.com

Your local distributor:

Please refer to www.perryequipment.com for your most current literature edition and address information.

FS-85-SL-01 (LHA 10/06) Printed in USA

S-ar putea să vă placă și