Sunteți pe pagina 1din 4

International Research Journal of Power and Energy Engineering

IRJPEE
Vol. 3(2), pp. 047-050, November, 2017. www.premierpublishers.org, ISSN: 3254-1213x

Conference Paper

Study and Estimation of Energy Transfer to the Active


DC-Link Capacitor Due to Harmonic Current
*Minakshi Kore1 and Balaji N2
1,2
Department of EEE, DSCE, Bangalore, India

Adjustable Speed Drives are extensively used in Processes Industries. To achieve optimum
performance parameters and high production output, it is necessary to operate the drive systems
at different speeds. Variable speed operation is realized by supplying the drive motor with variable
frequency supply through DC link inverter. When the drive system is operated at varying speeds,
it injects current harmonics into the DC link which are multiples of the operating fundamental
frequency. These harmonics are passed on to the grid lines with frequencies which are non-
integer multiples of the fundamental frequency of the Grid supply. These are called as injected
inter harmonics. This paper presents a methodology to estimate energy transfer to active DC link
capacitor due to inter-harmonics. It is necessary to calculate the amount of energy stored in
active capacitor, when the ripple energy is positive. The principle of mitigating the inter-harmonic
is transferring energy to the capacitor when the ripple energy is positive and during the negative
half cycle of the inter-harmonic the energy is fed back to the DC link. The work involves simulation
and analytical methods for the calculation of instantaneous voltage and current of capacitor and
inductor respectively.

Key words: Active DC-link capacitor, Adjustable Speed Drive (ASD), energy transfer mechanism, interharmonics.

INTRODUCTION

Due to large number of non-linear loads and generators in Flexible speed drives are one among the potential
the grid, the voltages and currents have become very wellsprings of inter-harmonics in the grid (H. Soltani et al.,
irregular in modern power systems. In such manner, control 2014), where a diode-connect rectifier and a PWM inverter
electronic based frameworks, for example, flexible speed are normally associated consecutive sharing a typical dc
drives, control supplies for IT-hardware and high interface having a LC-channel. Till now, a few examinations
effectiveness lighting and inverters in frameworks have been started to know the sources which creates the
producing power from dispersed sustainable power inter-harmonics, recognizable pieces of proof and their
sources are vital sources to make aggravations. negative impacts on the power supplies (D. Basic, 2010).
Contortions experienced are, for instance, signals which These reviews are truly helpful to recognize the inter-
are integer multiples of fundamental frequencies, inter- harmonic components, regardless more trials are required
harmonics, transients and flickering which are all for inter-harmonics reduction. Active DC link capacitor
components of 'energy quality' issues. compensation circuit is one of the effective method of
reducing these non-integer multiples of ripple components.
The frequencies which are not integer multiples of
fundamental frequency are called injected inter-harmonics *Corresponding author: Minakshi Kore, Department of
in to the grid which occurs due to nonlinear loads such as EEE, DSCE, Bangalore, India. Email:
adjustable speed drives. meena.pda705@gmail.com

Study and Estimation of Energy Transfer to the Active DC-Link Capacitor Due to Harmonic Current
Minakshi and Balaji 048

ACTIVE DC-LINK CAPACITOR COMPENSATION ESTIMATION OF ENERGY TRANSFER IN


CIRCUIT FOR INTERHARMONIC REDUCTION COMPENSATION CIRCUIT

The active dc link capacitor compensation circuit which The compensation of harmonic current calculated is
have become more popular in several power electronic depends on charging of the capacitor i.e. amount of ripple
applications, for example reduction of the dc link energy stored in the active capacitor. This depends on the
capacitance for single phase and three phase rectifiers is calculated ripple current at the load. The ripple component
one of the method for reducing the grid current inter- charges both the inductor and capacitor during switch on
harmonic components caused by the unbalanced currents time and the inductor releases its energy to capacitor
in motors (H. Soltani et al., 2015). Fig 1 demonstrates an during switch off time. Hence the energy in the active
adjustable speed drive with an active capacitor capacitor will be the sum of energy stored in the capacitor
compensation circuit. The dc link active capacitor and energy transferred from inductor. Figure 2 gives the
methodology is consist two IGBT Switches S1 and S2, an simulated circuit to estimate the charging of the capacitor
inductor La which is energy transferring element and also during each sampling period.
a capacitor Ca working as an energy storage element.

Fig.1. Adjustable speed drive with an active dc link


compensator

OPERATION PRINCIPLE FOR AN ACTIVE DC-LINK


CAPACITOR CIRCUIT

The proposed active capacitor circuit consists of two IGBT


switches, an inductor La and furthermore a capacitor Ca.
Here inductor is energy transferring element and capacitor
works as an energy storage element. The main aim is to
compensate the inverter side ripple energy initiated due to
Fig. 2. Simulation circuit to estimate the charging of the
load current imbalance. When the ripple energy (current) is
capacitor
positive, switch S1 is made on and off to sink the ripple
energy to the active capacitor of compensation circuit.
The above circuit was simulated using PSPICE. The
During the switch on time of S1, the ripple energy charges
graphs plotted from the simulated results for capacitor
the inductor and capacitor. Here, the capacitor is the main
voltage and inductor current validates the correctness of
storage component whereas the inductor only transfers the
the formulae discussed below.
ripple energy. During the off time of the switch S1, the ripple
energy the inductor transfers its energy to capacitor. This
The change in inductor current I is calculated from the
operating condition of compensation circuit is same as a
below formulae:
DC-DC step-down converter.
I1 = Im sin(t1) - Im sin(t0)
I2 = Im sin(t3) - Im sin(t2)
When the ripple energy component is negative, switch S2
In = Im sin(tn-1) - Im sin(tn)
is operated to release the stored ripple energy in active
capacitor back to the dc bus. During the on time of the
Change in capacitor voltage V at each sampling period is
switch S2 capacitor charges the inductor, during the switch
calculated as shown below
off time energy from both the active elements (La and Ca)
are transferred back to dc bus. This operating condition of
the circuit is same as a DC-DC step-up converter.
Study and Estimation of Energy Transfer to the Active DC-Link Capacitor Due to Harmonic Current
Int. Res. J. Power Energy Engin. 049

1
( + sin 0 ) Table 1. Theoretical values
V1 = 2

2
( + sin 2 )
V2 = 2


( + sin 1 )
Vn = 2

The amount of energy transferred to the capacitor from
inductor during switch off time can be calculated using
below formula

L
VL = Im
C

By considering the I and V the energy stored in capacitor


and inductor can be calculated.

Energy stored in inductor is


1
EL = I2
2
Energy stored in capacitor is
1
EC = V2
2

The values calculated are for quarter cycle, and for other
EXPERIMENTAL RESULTS quarter cycle the value is multiplied by two. These
calculated values are compared with simulation results and
From the below simulation results, it is evident that the the results are verified.
capacitor voltage gradually increases during the switch ON
time. The inductor transfers its stored energy to the
capacitor during the switch OFF time. CONCLUSIONS

Using P-spice simulation software the energy transfer


mechanism between the active capacitor and inductor is
established. The energy stored in the capacitor and
inductor are estimated analytically and are compared with
the simulation results. It has been established that during
one switching cycle of the ripple current, a comparison
between V and I by analytical method and simulation
method are matching.

REFERENCES

Basic D. (2010). Input current interharmonics of variable-


Fig 3. Simulation results speed drives due to motor current imbalance, IEEE
Trans. Power Del., vol. 25, no. 4, pp. 27972806.
Using the above formulae, the charging values of inductor Chang G. W., and Chen S. K. (2005). An analytical
current and capacitor voltage values for ripple energy of 5A approach for characterizing harmonic and
are calculated using excel sheet as shown in below table. interharmonic currents generated by vsi-fed adjustable
speed drives, IEEE Trans. Power Del., vol. 20, no. 4,
pp. 25852593.
Cho W., Powers E. J., and Santoso S. (2010). Mitigation
of harmonic and interharmonic effects using a dithering
method in adjustable speed drives, in IEEE Instrum.
and Meas. Technol. Conf. (I2MTC), pp. 14811485.

Study and Estimation of Energy Transfer to the Active DC-Link Capacitor Due to Harmonic Current
Minakshi and Balaji 050

Delaney E. J., and Morrison R. E. (1995). Minimisation of


interharmonic currents from a current source A.C. drive
by means of a selective D.C. side active filter, IEEE
Trans. Power Del., vol. 10, no. 3, pp. 15841590.
Dinavahi, Hatziadoniu C., Grady W., Gunther E., Halpin M.
et al., (2014) Interharmonics: theory and modeling.
Soltani H., Loh P. C., Blaabjerg F., and Zare F. (2014).
Interharmonic analysis and mitigation in adjustable
speed drives, in Proc. IEEE-IECON, pp. 15561561.
Soltani H., Loh P. C., Blaabjerg F., and Zare F. (2014).
Sources and mitigation of interharmonics in back-to-
back controllable drives, in Proc. IEEE-EPE, pp. P.1
P.9.
Soltani H., Loh P., Blaabjerg F., and Zare F. (2015).
Interharmonic mitigation of adjustable speed drives
using an active DC-link capacitor, in Proc. ICPEECCE
Asia, pp. 20182024.
Zhang Y., and Li Y. W. (2015). Investigation and
suppression of harmonics interaction in high-power
PWM current-source motor drives, IEEE Trans. Power
Electron., vol. 30, no.2, pp. 668679.

Accepted 23 October, 2017

Citation: Minakshi K and Balaji N (2017). Study H and


Estimation of Energy Transfer to the Active DC-Link
Capacitor Due to Harmonic Current. International
Research Journal of Power and Energy Engineering, 3(2):
047-050.

Copyright: 2017. Minakshi and Balaji. This is an open-


access article distributed under the terms of the Creative
Commons Attribution License, which permits unrestricted
use, distribution, and reproduction in any medium,
provided the original author and source are cited.