Documente Academic
Documente Profesional
Documente Cultură
R&Mfreenet Advanced
Cat 6 A Shielded Connection Module
June 2015
Technical Datasheet
Cat 6A Shielded Connection Module
Standards
IEC 60603-7-51: Electrical Characteristics of the Telecommunication Outlets
ISO/IEC 11801, Ed. 2.2: June 2011
EN50173-1: May 2011
June 2015
Technical Datasheet
Cat 6A Shielded Connection Module
Mechanical Data
**Re-termination may be performed with wire that is either larger or up to two wire gages smaller than wire
originally terminated.
Dimensions shielded
39.6
0.3
13.9
15.6
1.4
43 15.5
June 2015
Technical Datasheet
Cat 6A Shielded Connection Module
Electrical Data
Frequency Insertion Loss Return Loss NEXT (20C) [dB] all TCL (20C) PS ANEXT
(MHz) (20C) [dB] (20C) [dB] pair combinations [dB] (20C) [dB]
1.0 > -0.05 -49.9 -92.1 -86.3 -93.8
4.0 > -0.05 -50.5 -82.8 -76.9 -95.7
10.0 > -0.05 -47.7 -74.9 -69.3 -93.3
16.0 > -0.05 -45.3 -70.8 -65.2 -93.3
20.0 > -0.05 -44.3 -69.0 -63.3 -93.1
31.0 > -0.05 -41.7 -65.5 -59.7 -96.0
62.0 > -0.05 -37.3 -59.3 -53.6 -97.0
100.0 > -0.05 -32.5 -55.8 -48.7 -96.2
125.0 > -0.05 -30.1 -54.4 -46.8 -96.1
155.0 > -0.05 -28.1 -53.3 -45.3 -95.4
175.0 > -0.05 -26.9 -53.0 -44.0 -95.4
200.0 -0.06 -25.5 -52.7 -42.4 -93.1
250.0 -0.08 -23.1 -50.2 -41.2 -93.8
300.0 -0.12 -21.4 -47.4 -39.2 -83.6
400.0 -0.23 -19.1 -43.1 -36.9 -87.7
500.0 -0.42 -16.8 -38.4 -34.8 -87.6
June 2015
Technical Datasheet
Cat 6A Shielded Connection Module
Insertion Loss
Insertion Loss
0.00
-0.10
-0.20
-0.30
-0.40
Cat 6A ISO
[dB]
-0.50 12
36
-0.60
45
-0.70 78
-0.80
-0.90
-1.00
0 50 100 150 200 250 300 350 400 450 500
Frequency [MHz]
Return Loss
Return Loss
-5
-10
-15
Cat 6A ISO
-20
12
[dB]
-25
36
-30 45
78
-35
-40
-45
-50
0 50 100 150 200 250 300 350 400 450 500
Frequency [MHz]
June 2015
Technical Datasheet
Cat 6A Shielded Connection Module
NEXT 36-45
NEXT 36-45
-30
-35
-40
Cat 6A ISO, high low
-45
Cat 6A ISO, central
-50 high, central low
[dB]
36-45 high
-55
-75
-80
0 50 100 150 200 250 300 350 400 450 500
Frequency [MHz]
-30
-35
-40
-45
45-12 low
[dB]
-55
45-12 high
-60
45-78 low
-65 45-78 high
-70
-75
-80
0 50 100 150 200 250 300 350 400 450 500
Frequency [MHz]
June 2015
Technical Datasheet
Cat 6A Shielded Connection Module
-30
-35
-40
-45
36-12 low
-55
36-12 high
-60
36-78 low
-65
36-78 high
-70
-75
-80
0 50 100 150 200 250 300 350 400 450 500
Frequency [MHz]
NEXT 12-78
NEXT 12-78
-30
-35
-40
-45
-50
Cat 6A ISO
[dB]
-55
12-78 low
-65
-70
-75
-80
0 50 100 150 200 250 300 350 400 450 500
Frequency [MHz]
June 2015
Technical Datasheet
Cat 6A Shielded Connection Module
TCL
TCL
-10
-20
-40 36
45
-50 78
-60
-70
-80
0 50 100 150 200 250 300 350 400 450 500
Frequency [MHz]
PSANEXT
PS ANEXT
-50
-55
-60
-65
PS ANEXT
-70 Pair 12
[dB]
-75 Pair 36
-80 Pair 45
Pair 78
-85
-90
-95
-100
0 100 200 300 400 500
Frequency[MHz]
June 2015
Technical Datasheet
Cat 6A Shielded Connection Module
Keystone Cut-out
The keystone adapter ensures that the module will fit in keystone cut-outs as defined in IEC60603-7 ed. 3
Annex D.
Connector dimensions
Letter Maximum Minimum
mm mm
A1 16.51 16.00
B1 22.43 22.07
C1 12.65 12.34
J1 1.65 1.17
K1 9.78 9.53
L1 1.75 1.55
M1 5.46 5.16
P1 14.61 14.35
June 2015
Technical Datasheet
Cat 6A Shielded Connection Module
Mounting Dimensions
June 2015