Automatical aerosol extinguishing system

Areas of application:
 IT - server rooms
 computer centres
 central electrical control rooms
 garages
 stoke holds
 lift control rooms
 cars etc.

Your advantages: Price


 automatical fire detection
on request
 in case of fire the extinguishing system
starts immediatelly
 alarm signals will be transfered by email
 protection of hard drives and their informations
 minimal contruction measures

Features:
Technical Details and content matters:
 The extinguishing action of the aerosol works by Item number: AEROSOL50m
interrupting the self-sustained chemical reaction of
the fire. - Aerosol generators suited for rooms up to 50m capacity
- automatical fire detection and extinguishing system
 Aerosol dont reduce oxigene inside the safe area. according to EN54/EN12094-1
- 2 lines release system, 4 optical smoke detectors
 Aerosol is electrically non-conductive, so electrical - 1 fire detector based on temperature
equipment will not be damaged because of aerosol. - optical and acoustic alarm system
- SMS-Modem for alarm management
 Aerosol in non-toxic and do not cause organic - electric wiring and installation on site (in Austria)
build-up - certificates

All offers online: www.brodinger.at

BRODINGER phone: + 43 (0) 7675 20121


IT security technology fax.: + 43 (0) 7675 20122
Bahnhofstrasse 9 email: office@brodinger.at
4843 Ampflwang www.brodinger.at
Austria
www.brodinger.at

19 Cabinet gaseous fire suppression system


Fire prevention for server protection cabinets

Application:
 server cabinets
 network cabinets
 telecommunication cabinets

Advantages:
 self-assembly possible
 compact design only 3 HU
 easy to maintain
 easy to operate
 easy recovery after release
 solution for most of all cabinets
 possible to protect several cabinets with
only one fire suppression system
 aerosol ist electrically non conductive

Options:
 SNMP alarm
 possibility to install more smoke detectors
and extinguishing generators to increase
the size of the save area
 generator-kits for easy restart after release

installation example

BRODINGER phone: + 43 (0) 7675 20121


IT security technology fax: + 43 (0) 7675 20122
Bahnhofstrasse 9 email: office@brodinger.at
4843 Ampflwang www.brodinger.at
Austria
www.brodinger.at

19 Cabinet gaseous fire suppression system


Fire prevention for server protection cabinets

Function:
Two smoke detectors control the automatic
release of the gaseous fire suppression system. If
one of the smoke detectors identify smoke, the
system goes into pre-alarm status, showed by
LED. If the second fire detector identify smoke,
the system changes to main-alarm status and the
extinguishing system starts to float the area with
aerosol. During a short period of time, the aerosol
stay inside the cabinet and will extinguish the fire
immediately.
Front view in detail
Afterwards the cabinet can be opened and the
aerosol can dissipate easily, for example through
an open window. Aerosol is non-toxic for humans
and do not cause organic build-up. It is possible
to change easily the aerosol generators, after
resetting the system.
After the new generators are active, the whole
system is ready to start.
An additional door switch can deactivate the
system, when the door is open.

Funktional principle of aerosol:


Aerosol is electrically non-conductive, so electri-
cal equipment will not be damaged because of
aerosol.
An aerosol is defined as a system of solid or liquid
particles suspended in a gaseous medium. The Rear view with extinguisher
extinguishing action of the aerosol works by in-
terrupting the self-sustained chemical reaction of
the fire. Due to its special chemical composition,
the aerosol is capable of extinguishing fires even
if it is not sprayed directly on the fire; it works by
flooding the environment. Another important
feature of aerosol extinguishers is the slow deca-
ying process in the environment (the substance
tends to stratify), which allows it to maintain
enough inertia to prevent reignition of the fire.
BRODINGER phone: + 43 (0) 7675 20121
Aerosol extinguishers are completely environ- IT security technology fax: + 43 (0) 7675 20122
mentally friendly and do not deplete the ozone Bahnhofstrasse 9 email: office@brodinger.at
laye. 4843 Ampflwang www.brodinger.at
Austria
www.brodinger.at

19 Cabinet gaseous fire suppression system


Fire prevention for server protection cabinets

Differences between AEROSOL and NOVEC extinguishing-systems:

Aerosol Novec
extinguishing agent inside pressure tank NO YES
flap in case of overpressure neccessary NO YES
F-Gas containing product NO NO
EN Certificate YES YES
GWP (Global warming potential) 0 1
ODP (Ozone depletion potential) 0 0
ALT (Atmospheric lifetime) irrelevant 5 days
Conducting NO NO
Extinguisher cylinder in operation area YES NO
toxic NO NO
save area grouted during release YES YES
period of warranted function 20 years n/s
corrosivity NO NO
change of oxygene contend NO NO
re-filling station neccessary NO YES
extinguishing agent can easily be changed YES NO
floric acid grows out of extinguishing process NO YES
Server data storage test YES n/s
Extinguishing class A, B, C A, B

* Can be modified project-specifically


** Can be harmful

BRODINGER phone: + 43 (0) 7675 20121


IT security technology fax: + 43 (0) 7675 20122
Bahnhofstrasse 9 email: office@brodinger.at
4843 Ampflwang www.brodinger.at
Austria
www.brodinger.at

19 Cabinet gaseous fire suppression system


Fire prevention for server protection cabinets

ITSSBRL-RM ITSSBRL-RM

ITSSBRLAE-EG2 ITSSBRLAE2 ITSSBRLAE-EG2

RACK 01 RACK 02 RACK 03

Server rack solution for 3 Cabinets

Article Table
Artikel Item description
ITSSBRLAE1 19inch aerosol fire suppression system for server racks, 2 smoke detectors for 0,5 - 1 m volume
ITSSBRLAE2 19inch aerosol fire suppression system for server racks, 2 smoke detectors for 1 - 2 m volume
ITSSBRLAE1-K generator-kit for easy recovery after tripping, matching item ITSSBRLAE1
ITSSBRLAE2-K generator-kit for easy recovery after tripping, matching item ITSSBRLAE2
ITSSBRLAE-EG1 connectable aerosol generator for additional 1 m extinguishing volume
ITSSBRLAE-EG2 connectable aerosol generator for additional 2 m extinguishing volume
ITSSBRLAE-WEB IP-WEB SNMP monitoring with early fire detection and email alert
ITSSBRL-RM connectable optical smoke detector with 2 m cable

BRODINGER phone: + 43 (0) 7675 20121


IT security technology fax: + 43 (0) 7675 20122
Bahnhofstrasse 9 email: office@brodinger.at