2G RBS6000 Swap Procedure

CONTENTS

1 RBS6000 Hardware and Software.................................................................2


2 2G RBS6000 TRX Configuration....................................................................2
2.1 RUS Configuration for GSM&PCS....................................................2
3 2G RBS6000 Swap............................................................................................4
3.1 Flow chart for 2G rbs6000 swap........................................................4
3.2 Make use of OSS...................................................................................5
3.3 2G RBS6202 Swap and Command handling..................................7
3.4 2G RBS6601&6301 Swap...................................................................22
4 New RBS6000 Site...........................................................................................23
4.1 New site for CNA.................................................................................23
4.2 Command Handling With New Site................................................39
5 Abis Over IP Site Cutover.............................................................................43
5.1 Check status of the site and halted cell in BSC..........................43
5.2 Defines data of the transmission for IP.........................................44
5.3 Defines MO data of the new TG for IP site...................................44
5.4 Check the SIU status and activate the BTS again......................46
6 CESoPSN Site Cutover..................................................................................47
6.1 Site health check in BSC...................................................................47
6.2 Turn on the CRC for DIP in BSC......................................................48
6.3 Activate the BTS again......................................................................49
7 CS3CS4 Configuration...................................................................................50
7.1 TRX DCP Mapping For CS3CS4.......................................................50
7.2 TRX Timeslot and E1 Devices Relation.........................................51
8 MBC Site Configuration.................................................................................52
8.1 Cell parameter description...............................................................52
8.2 MO data description for GSM...........................................................57
8.3 MO data description for PCS............................................................58
8.4 PCS neighbour relation.....................................................................60
9 FAULT CODE LIST...........................................................................................61

1
1 RBS6000 Hardware and Software

Different for GSM900 and PCS1800

SYSTEM GSM900 PCS1800 PCS1800


RBS 6202&6601&6301 6601&6301 6601 6202 6202
SWVER B1305R061E B1305R061E B1305R061E B0705R031E
DU DUG 20 DUG 20 DUG 20 DUG 10
RUS
Board RU RUS 80W RRUS 60W RRUS 80W RUS 80W RUG
60W
Max TRX 3 4 3 4 4 2
Max Power 48 49 48 49 49 /
TX MPWR 43 43 43 47
BSPWRB/T <= 43 <= 43 <= 43 <= 45

2 2G RBS6000 TRX Configuration


2.1 RUS Configuration for GSM&PCS.

GSM900&GSM1800 3X3 (RUS 60W)

GSM900 TEI DCP1 DCP2 DCP3 MCTRI Max PWR Max TRX TX MPWR

0 128 129 130 0 48 3 43

CELLA 1 131 132 133 0 48 3 43

2 134 135 136 0 48 3 43

3 137 138 139 1 48 3 43

CELLB 4 140 141 142 1 48 3 43

5 143 144 145 1 48 3 43

6 160 161 162 2 48 3 43

CELLC 7 163 164 165 2 48 3 43

8 166 167 168 2 48 3 43

GSM900&GSM1800 3X3 (RUS 80W)

GSM900 TEI DCP1 DCP2 DCP3 MCTRI Max PWR Max TRX TX MPWR

CELLA 0 128 129 130 0 49 4 43

1 131 132 133 0 49 4 43

2 134 135 136 0 49 4 43

2
GSM900&GSM1800 3X3 (RUS 80W)

GSM900 TEI DCP1 DCP2 DCP3 MCTRI Max PWR Max TRX TX MPWR

3 / / / / / / /

4 140 141 142 1 49 4 43

5 143 144 145 1 49 4 43


CELLB
6 160 161 162 1 49 4 43

7 / / / / / / /

8 166 167 168 2 49 4 43

9 169 170 171 2 49 4 43


CELLC
10 172 173 174 2 49 4 43

11 / / / / / / /

2G RBS6000 RUG
Configuration.xls

2.2 RUG Configuration for PCS


The RUG of PCS have not MCTR mapping for 6202. The TRX configuration as below:

GSM1800 2P+2P (RUG)

GSM1800 TEI DCP1 DCP2 DCP3 MCTRI Max PWR Max TRX TX MPWR

0 128 129 130 / / 2 47


CELLA
1 131 132 133 / / 2 47

6 160 161 162 / / 2 47


CELLB
7 163 164 165 / / 2 47

GSM1800 3X3 (RUG)

GSM1800 TEI DCP1 DCP2 DCP3 MCTRI Max PWR Max TRX TX MPWR

0 128 129 130 / / 2 47

CELLA 1 131 132 133 / / 2 47

2 134 135 136 / / 2 47

4 140 141 142 / / 2 47

CELLB 5 143 144 145 / / 2 47

6 160 161 162 / / 2 47

CELLC 8 166 167 168 / / 2 47

3
GSM1800 3X3 (RUG)

GSM1800 TEI DCP1 DCP2 DCP3 MCTRI Max PWR Max TRX TX MPWR

9 169 170 171 / / 2 47

10 172 173 174 / / 2 47

2G RBS6000 RUS
Configuration.xls

3 2G RBS6000 Swap
3.1 Flow chart for 2G rbs6000 swap

2GMP

RAN TN
BTS SUPPORT CORERAN
(BSC)

NOC CENTER

1. 2GMP sends the 2G rbs6000 swap plan job in each last weekend.
2. We (BSC) will prepare the 2G rbs6000 swap scripts with the plan job.
3. If the plan job has new site or addition E1 site, TN_CORERAN will provide the E1 DSX
port.
4. We will send the jumper to CENTER prepare the connections.
5. Start for 2G rbs6000 site swap. BTS call NOC&BSC. NOC will be record. BSC will be
start halt site and input the script.
6. Wait the BTS completed the sites hardware and IDB. We will check the transmission
with BTS. If the transmission is WO that we will bring the MOs into service and unblocking the

4
MOs. If the transmission is ABL that BTS will be check the transmission cable.
7. Wait the BTS completed the antenna jumper. We will active the site and BTS will test call
on site.
8. Wait the BTS response the test call was completed. At this moment, 2G rbs6000 swap
was completed too.

3.2 Make use of OSS


1. Open the OSS. Choose the 1O or 2O->Enter.

2. Login OSS. Enter the User name and Password->OK.

5
3. Open the Command Handling. Choose the Start->Applications->Ericsson->Tools->AXE
Management-> Command Handling.

6
4. Copy and paste the Script in the Command Handling. Copy the script ->Right click the
input area for the command handling->Choose the Edit->Paste.

5. Connect BSC. Choose the Network Element->BSC15->Connect.

3.3 2G RBS6202 Swap and Command handling.


Command Description of 2G Swap.
1. Checking the cell status.
COMMAND: RLSTP:CELL=A2006A;

7
2. Change the cell status for halted.
COMMAND: RLSTC:CELL=A2006A,STATE=HALTED;

3. Check the status information for the managed objects (MO). The status as below
when the site will be halted.
COMMAND: RXMSP:MO=RXOTG- 432,SUBORD;

8
4. Check all of administration data for the MO instances. When parameter
SUBORD is used, MO instances are processed only if their superior MOs are
defined. The TG parameter as below before the RBS6000 swap.
COMMAND: RXMOP:MO=RXOTG-432;

9
5. Check the DIP status. There are 3 statuses of WO (Working) or MBL
(Manually blocked) or ABL (Automatically blocked) with the DIP.
COMMAND: DTSTP:DIP=152RBL2;

6. Deblock the specified DIP, when the DIP status was MBL:
COMMAND:DTBLE:DIP=152RBL2;

7. Check the device state details. The start DEV = DIP*32 and the end

10
DEV = start DEV + 31.
COMMAND: STDEP:DEV=RBLT2-46864&&-4895;

8. Brings a device into service from a PRE-POST SERVICE state. It is not


allowed to bring RBLT devices into service in a stand-alone Transcoder Controller
(TRC) and transcoder devices into service when the node type is stand-alone Base
Station Controller (BSC).
COMMAND: EXDAI:DEV=RBLT2-4864&&-4895;

9. Requests the deblocking of the specified device(s), up to a maximum of 32


devices per invocation of the command. A device will normally be put into the idle
state, but will remain in the blocked state if it is faulty or not connected. Deblocking of
the specified devices, when the RBLT devices were MBL
COMMAND: BLODE:DEV=RBLT2-6496&&-6527;
Before deblocked the devices status as below:

11
After deblocked the devices status as below:

10. Change the software version. GSM900: B1305R061E / GSM1800:


B0705R031E.
COMMAND: RXMSC:MO=RXOTG-432,SWVER=B1305R061E;

12
11. Manual forced blocking indication the subordinate MOs.
COMMAND: RXBLI:MO=RXOTG-432,SUBORD,FORCE;

13
12. Out of service for the subordinate MOs. The MOs must be manually blocked,
that is in state COM.
COMMAND: RXESE:MO=RXOTG-432,SUBORD;

13. Change the CF terminal endpoint identifier. When the MOs out of service can
be use the RXMOC change all of the MOs configurations. In general practice,

14
GSM900 = 1st TG &
GSM1800 = 2nd TG in the cascade stream. TEI value of CFs = 62, 61, 60and so
on.
COMMAND: RXMOC:MO=RXOCF-432,TEI=62;

14. Deletes specified Abis paths between the Base Station Controller (BSC) and
the BTS for a specified TG in the transmission mode TDM. The last Abis path within a
TG will only be deleted if its associated transmission device does not have a
connected Digital Path (DIP).
COMMAND: RXAPE:MO=RXOTG-432,DCP=ALL;

15. Defines one or more Abis paths between the Base Station Controller (BSC)
and the BTS. This command is only valid if TG is in the transmission mode Time
Division Multiplexing (TDM).
COMMAND: RXAPI:MO=RXOTG-432,DCP=1&&15,DEV=RBLT2-4865&&-4879;

15
To facilitate the deployment of CS-3/4 & EDGE, for 2xE1 and 2xDUG case (dual band or large
configuration), please connect both E1s to the 1st DUG and then cascade them to the 2nd
DUG. For this configuration, we can dynamically assign TSs of these 2xE1 between the two
DUGs.

16. Define the TRX tei value and dcp mapping in the BSC.
COMMAND: RXMOI:MO=RXOTRX-432-0,TEI=0,DCP1=128,DCP2=129&130;

17. Adding new TRX.


COMMAND: RXMOI:MO=RXOTRX-432-0,TEI=0,DCP1=128,DCP2=129&130;
COMMAND: RXMOC:MO=RXOTRX-432-0,CELL=A2006A,SIG=UNCONC;
COMMAND: RXMOI:MO=RXOTX-432-0,BAND=GSM900,MPWR=43; (GSM)
COMMAND: RXMOI:MO=RXOTX-432-0,BAND=GSM1800,MPWR=47; (PCS)
COMMAND: RXMOI:MO=RXORX-432-0,RXD=AB,BAND=GSM900; (GSM)

16
COMMAND: RXMOI:MO=RXORX-432-0,RXD=AB,BAND=GSM1800; (PCS)
COMMAND: RXMOI:MO=RXOTS-4321-0-0&&-7;
COMMAND: RXMOC:MO=RXOTX-432-0,CELL= A2006A;
The GSM900 TRX parameter as below:

The GSM1800 TRX dont mapping MCTR for RBS6000 RUG. Its TRX parameter as
below:

18. Adding the MCTR for the GSM. PCS dont mapping the MCTR for RBS6000
RUG.
COMMAND: RXMOI:MO=RXOMCTR-432-0,MAXPWR=48,MAXTRX=3; (RUS 60W)
COMMAND: RXMOI:MO=RXOMCTR-432-0,MAXPWR=49,MAXTRX=4; (RUS 80W)
COMMAND: RXMOC:MO=RXOTRX-432-0,MCTRI=0;

17
COMMAND: RXMOC:MO=RXOTRX-432-1,MCTRI=0;
COMMAND: RXMOC:MO=RXOTRX-432-2,MCTRI=0;

19. Check the power for the cell.


COMMAND: RLCPP:CELL=A2006A&A2006B;

20. Change the power for the cell.


COMMAND: RLCPC:CELL=A2006A,BSPWRB=42,BSPWRT=42;
COMMAND: RLCPC:CELL=A2006A,BSPWRB=40,BSPWRT=40;

BSPWRB/BSPWRT for GSM900 power is set to 31~43, in 1 dB steps. If 4 TRXs in the


RUS 60W, that max power is 42dBm (15W).
BSPWRB/BSPWRT for GSM1800 power is set to 33~45, in 2 dB steps. Hence, only
ODD number is valid.

21. Brings MOs into service and manual unblocking the MOs.
COMMAND: RXESI:MO=RXOTG-432,SUBORD;

18
COMMAND: RXBLE:MO=RXOTG-432,SUBORD;

19
22. Check the MOs status. When all of the MOs states are operation, the cell can
be active.
COMMAND: RXMSP:MO=RXOTG-432,SUBORD;

23. Check the fault information for CF.


COMMAND: RXMFP:MO=RXOCF-432,SUBORD,FAULTY;

20
Above fault code is CF-2A69 (Cabinet Product Data Mismatch). Action: Add the values stated
on the cabinet enclosure label to the IDB description by BTS team. Can be checking the alex
fault list for RBS6000. It path as below: http://alex/cgi-bin/alex

24. Change the cell status in active.


COMMAND: RLSTC:CELL=A2006A,STATE=ACTIVE;

25. Supervision of logical channels availability data for the cell.


COMMAND: RLSLP:CELL=A2006A;

21
26. Change the limit value for availability with traffic channel.
COMMAND: RLSLC:CELL=A2006A,CHTYPE=SDCCH,LVA=15;
COMMAND: RLSLC:CELL=A2006A,CHTYPE=TCH,LVA=21;

27. Check the cell resources.

The scripts & MO data of 2G RBS6202 swap as below:


Config: 2G+3G Config: 2P+2P

B16_Z2402AB_RBS B16_Z2402AB_RBS B11_S3480A_RBS6 B11_S3480AB_RBS


6202_Script.TXT 6202_GSM_MO.txt 000_Script.txt 6202_PCS_MO.txt

3.4 2G RBS6601&6301 Swap.


The MOs configuration of GSM for the site 6202&6601&6301 are same in BSC side. But the
site 6601&6301 of PCS are the same as GSM 6202. If the GSM&PCS are 6601 or 6301 that

22
they are only one TG number.
The scripts & MO data of 2G RBS6601 swap as below:
Config: 4G+2P

B14_W1773A&W34 B14_W1773A&W34
04A_RBS6601_Script.txt 04A_RBS6601_MO.txt

The scripts & MO data of 2G RBS6301 swap as below:


Config: 2G+2P

B15_Y1829B&Y382 B15_Y1829B&Y382
9B_RBS6301_Script.TXT9B_RBS6301_MO.txt

4 New RBS6000 Site


4.1New site for CNA
Below is the Process describes how to define a new site with CNA
1. Find the new site parameter in CR.
Input the site number or CR number on the website: www.hope.com to look for corresponding
parameters.

23
Open the attachment files with CR, can be look at the parameter for the site.

2. Open a CNA and set up a new plan area.


File->new area->plan area

Input the plan area name and click new.

24
3. Set up new site in the plan area (b16_z2406b).
Edit->New->Site

Input the specific parameters into the corresponding blank area, and then click new.

25
4. Set up new cell in the plan area b16_z2406b.
Edit->New->Cell->Internal

Input Cell name and system type, and then click OK

26
5. Set up inner cell
Input CO and RO, then click OK.

6. Set up channel group


Input corresponding parameters to channel group, then click OK

27
7. Fine a cell template in the same BSC, and then copy all the parameters to the new
cell.
Selected the cell template. Edit->Copy->All Parameters.

Select the defined new cell. Edit->paste. then change the parameters as the follow
pictures showed.

28
29
30
If all parameters are input the new cell plan area, then click OK.

31
8. Define Neighbor cells of the new cell.
Input Neighbor cell name, choose CS type, if the neighbor cell is internal cell with new cell,
please choose the CS to YES, else choose NO, and then click New. Keep doing this step
until all neighbor cells defined.

9. Change the parameters of all neighbor cells.


Selected the new cell, and then View->neighbor relations.

Right click select all, View->Objects in table.

32
Change the parameters of all neighbor cell, then Edit->Apply.

10. Check all parameters of the new cell.


Check the number of the neighbor cells: Select new cell, then View->Neighbor relations.

33
Check internal cell properties.

34
Check inner cell properties.

Check channel group properties.

12. Update new plan area.


Select new plan area, and then File->New job->Update job

35
Input update job name, update of BA list choose Unconditional, Fallback area
choose YES, and then click OK.

36
13. Check the state of the update job. File->Jobs->My own.

37
Check the update job report

NOTICE: If the CNA update job is failed, look into the ALEX (http://alex/cgi-bin/alex)
for help.

14. Check if all the cell parameters are correctly defined. Open a command handling
and input corresponding commands.

38
4.2 Command Handling With New Site.
1. Check the new cell parameters in the BSC with command handling.
RLDEP:CELL=XXX;
Command description: prints cell description data

RLCFP:CELL=XXX;
Command description: prints cell configuration frequency data.

39
RLDHP:CELL=XXX;
Command description: prints dynamic hr allocation data.

RLPRP:CELL=XXX;
Command description: prints BSC differential channel allocation priority profile resource
type data.

RLGSP:CELL=XXX;
Command description:prints GPRS data.

RLNRP:CELL=XXX,CELLR=ALL;
Command description: prints all the neighbour cells and relation data.

40
RLMFP:CELL=XXX;
Command description: prints all the measurement frequencies of specific cell.

RLCPP:CELL=XXX;
Command description: prints cell configuration power data.

RLLHP:CELL=XXX;
Command description: prints cell locating hierarchical data.

41
2. Define a New TG For the New Site
RXMOI:MO=RXOTG-
58,SWVER=B1305R061E,TRACO=POOL,RSITE=LOC_2402,COMB=HYB;
Command description: De f ine tg -5 8 fo r th e site 24 02 , B TS so f t wa re ve rsio n is
B1 30 5 R06 1 E . Tran scod e r con ne ct io n t ype is P OO L , ra d io sit e na me is
LO C_ 24 02 , an d co mb ine r is HY B (Hyb rid ) co mb ine r.

RXMOC: MO=RXOTG-58, FHOP=BB;


Command description: Changes the hopping type as basic band.

RXMOI: MO=RXOCF-58, TEI=62;


Command description: Defines CF MO in tg-58, the address of the equipment is 62. (62 for
the master cabinet, 61 for the slave cabinet.)

RXMOC: MO=RXOCF-58, SIG=UNCONC;


Command description: Changes signalling type of CF58 as Unconcentrated link.

RXMOI: MO=RXOIS-58;
Command description: Defines IS MO in tg-58. The IS is short for interface switch.

RXMOI: MO=RXOTF-58, TFMODE=SA;


Command description: Defines TF MO in tg-58. The TF synchronization mode is defined as
stand-alone.

RXTCI: MO=RXOTG-58, CELL=Z2402A, CHGR=0;


Command description: Connects channel group 0 of cell Z2402A to tg-58.
New site script for GSM&PCS co-site (2G+3G+2P).

B16_Z2402AB&Z30
18A_New site script.TXT

42
5 Abis Over IP Site Cutover

Abis over IP solution

Abis over IP site cutover is change the transmission of between the BSC and the BTS from
TDM transport networks to IP or ethernet transport service
In the preparation phasesend the TG PSTU name for the Abis over IP site to TN team

The following format:


GSM PCS GSM TG PCS TG
3G
BSC Site Site Abis/CES RBLT DSX PSTU PSTU
No.
No. No. name name

17 560 4092 84092 Abis / / 1022 1023

Abis Over IP Site Cutover Scripts.


5.1 Check status of the site and halted cell in BSC.
1Check status informationfault informationMO date of the siteMake sure
after cutover the same as before cutover
Command: RLSTP:CELL=Z2516A;
Command: RXMFP:MO=RXOCF-213,SUBORD,FAULTY;
Command: RXMSP:MO=RXOTG-213,SUBORD;
Command: RXMOP:MO=RXOTG-213,SUBORD;

2Halted cell and blocked MO in BSC


CommandRLSTC:CELL=Z2516A,STATE=HALTED;
CommandRXBLI:MO=RXOTG-213,SUBORD,FORCE;
CommandRXESE:MO=RXOTG-213,SUBORD;

43
CommandRXTCE:MO=RXOTG-213,CHGR=0,CELL=Z2516A;

5.2 Defines data of the transmission for IP.


1Define PSTU in BSC. The PSTU namePSTU=TG[TG number]follow the TG
NO. and should be exact match with the on site SIU setting. Corresponding
parameters are common to all various TGs & PSTUs.
CommandRRPTI:PSTU=TG101,LBG=1&1&2&2&3,SAPI=0&62&10&11&12;

2Define the SCGR, Super Channel Group: SCGR=[TG number], the SCGR no.
follow the TG NO. Corresponding parameters are common to all various TGs &
SCGRs.

Command:RRSGI:SCGR=101,MODE=IPM,PSTU=TG101,MBWDL=8192,MBWUL=
8192,JBSUL=20;

3Define 4 SCs (superchannel) for the SCGR defined. SC=[0...3].Corresponding


parameters are common to all various TGs and SCs.
Command: RRSCI:SCGR=101,SC=0,DCP=1,NUMDEV=31;
Command: RRSCI:SCGR=101,SC=1,DCP=33,NUMDEV=31;
Command: RRSCI:SCGR=101,SC=2,DCP=287,NUMDEV=31;
Command: RRSCI:SCGR=101,SC=3,DCP=319,NUMDEV=31;

Auxiliary information only:


# DP0 or PCM A: DCP 1-31
# DP1 or PCM B: DCP 33-63
# DP2 or PCM C: DCP 287-317
# DP3 or PCM D: DCP 319-349

5.3 Defines MO data of the new TG for IP site.


1. Define TG with specific parameters:TMODE=SCM & SCGR=[TG no.]PTA=10 &
JBSDL=20 & JBPTA=20.
Command: RXMOI:MO=RXOTG-101,COMB=HYB,RSITE=6201,SWVER=B0705R031E;
Command:
RXMOC:MO=RXOTG101,TMODE=SCM,SCGR=101,PTA=10,JBSDL=20,JBPTA=20;

2. Define CF with specific parameters:SIG=SCCONC


CommandRXMOI:MO=RXOCF-101,TEI=62,SIG=SCCONC;

44
3. Define TF and ISthe same as E1 site
CommandRXMOI:MO=RXOTF-101,TFMODE=SA;
CommandRXMOI:MO=RXOIS-101;

4. Define RXOCON on each TG with AbisoIPDCP=350&&581 is common for all


various TGs
CommandRXMOI:MO=RXOCON-101,DCP=350&&581;

5. Define TRXs DCP with CS3CS4 / EGPRS settingsThese are one SC NO. for the
TRX must be 0 on each TG with AbisoIP.
!Assign each TRXs with ascending SC no. for the TRXs,!
! TEI Value: SC number: !
! 0/4/8 0 !
! 1/5/9 1 !
! 2 / 6 / 10 2 !
! 3 / 7 / 11 3 !
Command RXMOI:MO=RXOTRX-101-0,TEI=0,DCP1=178,DCP2=179&&186,SC=0;
Command RXMOI:MO=RXOTRX-101-1,TEI=1,DCP1=187,DCP2=188&&195,SC=1;
Command RXMOI:MO=RXOTRX-101-2,TEI=2,DCP1=196,DCP2=197&&204,SC=2;
Command RXMOI:MO=RXOTRX-101-3,TEI=3,DCP1=205,DCP2=206&&213,SC=3;

6. Define TX/RX/TSthe same as E1 site


Command RXMOI:MO=RXORX-101-0&&-3,RXD=AB,BAND=GSM900;
Command RXMOI:MO=RXOTX-101-0&&-3,MPWR=42,BAND=GSM900;
Command RXMOI:MO=RXOTS-101-0-0&&-7;
Command RXMOI:MO=RXOTS-101-1-0&&-7;
Command RXMOI:MO=RXOTS-101-2-0&&-7;
Command RXMOI:MO=RXOTS-101-3-0&&-7;

7. Define MCTR if necessary, (if using DUG-20; RUS or RRUS hardware)the


same as E1 site
Command RXMOI:MO=RXOMCTR-101-0,MAXPWR=48,MAXTRX=3,TXMPWR=AUTO;
Command RXMOC:MO=RXOTRX-101-0,MCTRI=0;
Command RXMOC:MO=RXOTRX-101-1,MCTRI=0;
Command RXMOC:MO=RXOTRX-101-2,MCTRI=0;
Command RXMOC:MO=RXOTRX-101-3,MCTRI=0;

8. Connects cell to TG.

45
Command RXTCI:MO=RXOTG-101,CELL=[Cell Name],CHGR=0;
5.4 Check the SIU status and activate the BTS again.
1. Prints the data for PSTU.
Command RRPTP:PSTU=TG101;
The PSTU is not ready:

The PSTU is ready. We can brings the MOs into service.

2. Prints the data for SCGR.


Command RRSGP:SCGR=101;

3. Prints the data for SCs.


Command RRSCP:SCGR=101;

4. Brings MOs into service.


Command RXESI:MO=RXOTG-101,SUBORD;

46
5. Orders the manual unblocking of the Moinstance.
Command RXBLE:MO=RXOTG-101,SUBORD;

6. Check the status and fault information after cutover.


Command RXMSP:MO=RXOTG-101,SUBORD;
Command RXMFP:MO=RXOCF-101,SUBORD,FAULTY;

7. Changes the state active of defined cell.


Command RLSTC:CELL=Z2516A,STATE=ACTIVE;

6 CESoPSN Site Cutover

CESoPSN Encapsulation for emulation of low-rate TDM circuits over PSN. In the
bsc, CESoPSN site cutover main task is change CRCCyclic redundancy checkof
the transmission from 0 to 2. 0is no CRC, only Frame Alignment Signal word
violations are counted as bitfaults. 2 is CRC-4 ,performed on both outgoing and
incoming PCM bitstream, and E-bits will be sent to the remote end. The remote end
must have the same type of supervision.
In the preparation phasesend the RBLT for CES site to TN team.
The following format:
GSM PCS GSM TG PCS TG
3G
BSC Site Site Abis/CES RBLT DSX PSTU PSTU
No.
No. No. name name

17 838 85160 CES 137 33/2/31 / /

CESoPSN Site Cutover scripts


For example of the site 0838.

6.1 Site health check in BSC.


1. Prints cell resources.
CommandRLCRP:CELL=A0838R;

2. Prints the status information for managed objects.


CommandRXMSP:MO=RXOTG-230,SUBORD;

47
3. Prints all administration data for one or more MO instances.
CommandRXMOP:MO=RXOTG-230,SUBORD;

4. Prints all defined Abis paths for specified TG in the BTS. Write down the DEV and DCP.
CommandRXAPP:MO=RXOTG-230;

5. Printing of fault information for managed object.


CommandRXMFP:MO=RXOCF-230,SUBORD,FAULTY;

6. Initiates a printout of the state for the specified DIP.


CommandDTSTP:DIP=137RBL2;

7. Initiates a printout of all initial data for the specified digital path.
CommandDTIDP:DIP=137RBL2;

CESoPSN site cutover main task is change CRC (Cyclic redundancy check) of the
transmission from 0 to 2.

6.2 Turn on the CRC for DIP in BSC


1. Changes the state of defined cell.
CommandRLSTC:CELL=A0838R,STATE=HALTED;

2. Orders the manual blocking of Mos.


CommandRXBLI:MO=RXOTG-230,SUBORD,FORCE;

48
3. Removes specified MOs from service.
CommandRXESE:MO=RXOTG-230,SUBORD;

4. Deletes specified Abis paths between the BSC and the BTS in the transmission.
CommandRXAPE:MO=RXOTG-230,DCP=ALL;

5. Requests blocking of the specified device.


CommandBLODI:DEV= RBLT2-4384&&-4415;

6. Initiates blocking of the specified digital path.


CommandDTBLI:DIP=137RBL2;

7. Change CRC of the transmission from 0 to 2.


CommandDTIDC:DIP=137RBL2,CRC=2;

8. Initiates a printout of all initial data for the specified digital path.
CommandDTBLE:DIP=137RBL2;

6.3 Activate the BTS again


1. Requests the deblocking of the specified device.
CommandBLODE:DEV=RBLT2-4384&&-4415;

2. Initiates a printout of the state for the specified DIP WOthe transmission is
OK. ABL, the transmission is Disconnect.
CommandDTSTP:DIP=137RBL2;
Procedure Printouts

3. Defines one or more Abis paths between the BSC and the BTSThe DEV and
DCP are the same as before cutover.

49
CommandRXAPI:MO=RXOTG-230,DCP=1&&6,DEV=RBLT2-4385&&-4390;

4. Prints all defined Abis paths for specified TG in the BTS again.
CommandRXAPP:MO=RXOTG-230;

5. Brings MOs into service.


CommandRXESI:MO=RXOTG-230,SUBORD;

6. Orders the manual unblocking of the Moinstance.


CommandRXBLE:MO=RXOTG-230,SUBORD;

7. Prints the status information for managed objects again.


CommandRXMSP:MO=RXOTG-230,SUBORD;

8. Changes the state of defined cell.


CommandRLSTC:CELL=A0838R,STATE=ACTIVE;

9. Prints out supervision of logical channels availability data.


CommandRLSLP:CELL=A0838R;

10. Prints cell resources again.


CommandRLCRP:CELL=A0838R;

7 CS3CS4 Configuration

7.1 TRX DCP Mapping For CS3CS4

TRX TEI DCP1 DCP2

0 178 179&&186

1 187 188&&195

2 196 197&&204

3 205 206&&213

4 214 215&&222

5 223 224&&231

6 232 233&&240

7 241 242&&249

8 250 251&&258

50
TRX TEI DCP1 DCP2

9 259 260&&267

10 268 269&&276

11 277 278&&285

Command:
RXMOI:MO=RXOTRX-XXX-0,DCP1=178,DCP2=179&&186;
RXMOI:MO=RXOTRX- XXX-1,DCP1=187,DCP2=188&&195;
RXMOI:MO=RXOTRX- XXX-2,DCP1=196,DCP2=197&&204;
RXMOI:MO=RXOTRX- XXX-3,DCP1=205,DCP2=206&&213;
RXMOI:MO=RXOTRX- XXX-4,DCP1=214,DCP2=215&&222;
RXMOI:MO=RXOTRX- XXX-5,DCP1=223,DCP2=224&&231;
RXMOI:MO=RXOTRX- XXX-6,DCP1=232,DCP2=233&&240;
RXMOI:MO=RXOTRX- XXX-7,DCP1=241,DCP2=242&&249;
RXMOI:MO=RXOTRX- XXX-8,DCP1=250,DCP2=251&&258;
RXMOI:MO=RXOTRX- XXX-9,DCP1=259,DCP2=260&&267;
RXMOI:MO=RXOTRX- XXX-10,DCP1=268,DCP2=269&&276;
RXMOI:MO=RXOTRX- XXX-11,DCP1=277,DCP2=278&&285;

7.2 TRX Timeslot and E1 Devices Relation


Example: 2TRX E1 devices mapping with RBLT0. The E1 devices of 0&16 dont to
use.

COMMON TRX AND E1 DEVICES RELATION

TRX Timeslot

Control Channel 0 0 1 2 3 4 5 6 7

E1 Devices 0 1 2 3 16 31 Total 32
NUMREQCS3CS4BPC = 0

1. Common TRX and devices relation


Command:
RXAPI:MO=RXOTG-XXX,DCP=1&&6,DEV=RBLT-1&&-6;

2. CS3CS4 TRX and devices relation

51
CS3CS4 TRX AND E1 DEVICES RELATION

TRX Timeslot

Control Channel 0 0 1 2 3 4 5 6 7

RES64K

E1 Devices 0 1 2 3 4 5 6 16 31 Total 32
NUMREQCS3CS4BPC = 4

Command:
RXAPI:MO=RXOTG-XXX,DCP=1&&6,DEV=RBLT-1&&-4,RES64K;
RXAPI:MO=RXOTG-XXX,DCP=1&&6,DEV=RBLT-5&&-6;
RLGSC:CELL=XXXX, CHCSDL=CS4;
RLBDC:CELL=XXXX, NUMREQCS3CS4BPC=4;

CS3CS4 TRX AND E1 DEVICES RELATION

TRX Timeslot

Control Channel 0 0 1 2 3 4 5 6 7

RES64K

E1 Devices 0 1 2 3 4 5 6 7 8 9 16 31 Total 32
NUMREQCS3CS4BPC = 8

Command:
RXAPI:MO=RXOTG-XXX,DCP=1&&6,DEV=RBLT-1&&-8,RES64K;
RXAPI:MO=RXOTG-XXX,DCP=1&&6,DEV=RBLT-9&&-12;
RLGSC:CELL=XXXX, CHCSDL=CS4;
RLBDC:CELL=XXXX, NUMREQCS3CS4BPC=8;

RBS6000 CS3CS4
Script.txt

8 MBC Site Configuration


8.1 Cell parameter description
1. Halt site and expand the channel group for gsm1800.
RLSTC:CELL=V2263C,STATE=HALTED;

52
RLDSI:CELL=V2263C;
RLDGI:CELL=V2263C,SCTYPE=OL,CHGR=1,BAND=GSM1800;

2. Check the cell configuration frequency data, then add the PCS frequency
and hopping sequence number to the expansion channel group. Relocate
PCS SDCCH to GSM, if GSM had 2 CHGR, then relocate SDCCH to CHGR
with GSM BCCH.
RLCFP:CELL=V2263C&V5589C;
RLCFI:CELL=V2263C,CHGR=1,DCHNO=523&662;
RLCHC:CELL=V2263C,CHGR=1,HOP=ON,HSN=34,MAIO=DEFAULT;
RLCCC:CELL=V2263C,CHGR=0,SDCCH=2;

3. Check the power of PCS, then add them to overlaid subcell.


RLCPP:CELL=V5589C;
RLCPC:CELL=V2263C,BSPWRT=45,MSTXPWR=30,SCTYPE=OL;

53
4. Defined the cell locating overlaid subcell data for designated value.
RLOLC:CELL=V2263C,LOL=130,LOLHYST=2,TAOL=61,TAOLHYST=0,DTCBHYST=0,NDIS
T=0,NNCELLS=1;

5. Turn the subcell load distribution status on, and then change the subcell
load distribution data for designated value.
RLLLC:CELL=V2263C,SCLD=ON,SCLDSC=OL,SCLDLOL=20,SCLDLUL=30;

6. Change the cell locating intracell handover data of overlaid subcell for
designated value.
RLIHC:CELL=V2263C,SCTYPE=OL,IHO=ON,MAXIHO=3,TMAXIHO=6,TIHO=5;

54
7. Change the cell locating data for designated value.
RLLOC:CELL=V2263C,FBOFFSP=7;
RLLOC:CELL=V2263C,SCTYPE=UL,BSTXPWR=50;
RLLOC:CELL=V2263C,SCTYPE=OL,BSTXPWR=39;

55
8. Change the cell locating hierarchical data for designated value.
RLLHC:CELL=V2263C,LAYER=2,LAYERTHR=75;

9. The AMR power control cell data of overlaid subcell match underlaid
subcell.
RLAPC:CELL=V2263C,SCTYPE=OL,ssdesdlafr=85,qdesdlafr=30,qdesulafr=35;
RLAPC:CELL=V2263C,SCTYPE=OL,ssdesdlahr=85,qdesdlahr=30,qdesulahr=35;

10. The dynamic ms power control cell data of overlaid subcell match
underlaid subcell.
RLPCC:CELL=V2263C,SCTYPE=OL,qdesul=35;

56
11. The dynamic BTS power control cell data of overlaid subcell match
underlaid subcell.
RLBCC:CELL=V2263C,SCTYPE=OL,ssdesdl=85;

12. Change the underlaid subcell support cell general packet radio service.
RLGSC:CELL=V2263C,scalloc=UL;

13. Change the connection of cell to channel allocation profile data for
designated value.
RLHPC:CELL=V2263C,chap=6;

57
8.2 MO data description for GSM
1. Change the GSM frequency hopping for baseband hopping.
RXMOC:MO=RXOTG-60,FHOP=BB;

2. Change the GSM TF synchronization mode for master, and the TG cluster
identity for designated value.
RXMOC:MO=RXOTF-60,TFMODE=M;
RXMOC:MO=RXOTG-60,CLUSTERID=3;

3. Connect the cell of GSM to the CHGR 0 with tg-60.


RXTCI:MO=RXOTG-60,CELL=V2263C,CHGR=0;

4. Connect the trx and tx of GSM to the CHGR 0 with tg-60.


RXMOC:MO=RXOTX-60-10,CELL=V2263C,CHGR=0;
RXMOC:MO=RXOTRX-60-10,CELL=V2263C,CHGR=0;

58
8.3 MO data description for PCS
1. End the GPRS for PCS and support the GPRS for GSM.
RLGSE:CELL=V5589C;
RLGSI:CELL=V2263C;

2. Change the PCS frequency hopping for Synthesizer hopping.


RXMOC:MO=RXOTG-14,FHOP=SY;

3. Change the PCS TF synchronization mode for slave, and the TF


compensation value from operation and maintenance terminal (OMT) within
the function TG Synchronization. And the TG cluster identity match GSM.
RXMOC:MO=RXOTF-14,TFMODE=S,TFCOMPPOS=OMT;
RXMOC:MO=RXOTG-14,CLUSTERID=3;

4. Disconnect the before PCS cell for the CHGR 0 with tg-14 and connect
after PCS cell for the CHGR 1 with tg-14.
RXTCE:MO=RXOTG-14,CELL=V5589C,CHGR=0;
RXTCI:MO=RXOTG-14,CELL=V2263C,CHGR=1;

5. Connect the trx and tx of PCS to the CHGR 1 with tg-14.


RXMOC:MO=RXOTX-14-0,CELL=V2263C,CHGR=1;

59
RXMOC:MO=RXOTRX-14-0,CELL=V2263C,CHGR=1;

6. Active the overlaid subcell alarm issue.


RLSLI:CEll=V2263C,SCTYPE=OL;

7. Change the channel alarm limit value for availability to specified value.
RLSLC:CELL=V2263C,SCTYPE=UL,CHTYPE=SDCCH,ACL=A1,LAV=15;
RLSLC:CELL=V2263C,SCTYPE=UL,CHTYPE=TCH,ACL=A1,LAV=21;
RLSLC:CELL=V2263C,SCTYPE=UL,CHTYPE=BCCH,ACL=A1;
RLSLC:CELL=V2263C,SCTYPE=OL,CHTYPE=BCCH,ACL=A1;
RLSLC:CELL=V2263C,SCTYPE=OL,CHTYPE=SDCCH,ACL=A1;
RLSLC:CELL=V2263C,SCTYPE=OL,CHTYPE=TCH,ACL=A1,LAV=16;

8.4 PCS neighbour relation.


Move the old PCS neighbour relation to the after PCS.
1. Handover out for 2G.
RLNRI:CELL=V2263C,CELLR=A5087C;
RLNRC:CELL=V2263C,CELLR=A5087C,HIHYST=4,OFFSETP=0,AWOFFSET=6;

60
2GHO_Script.txt

2. Handover in for 2G.


RLMFC:CELL=A5087C,MBCCHNO=103,MRNIC;
RLNRI:CELL=A5087C,CELLR=V2263C;
RLNRC:CELL=A5087C,CELLR=V2263C,HIHYST=4,OFFSETP=0,AWOFFSET=6;

2GHI_Script.txt

3. Handover out for 3G.


RLUMC:CELL=V2263C,ADD,UMFI=10737-107-DIV;
RLNRI:CELL=V2263C,CELLR=81915A,SINGLE;

3GHO_Script.txt

4. Neighbour relation of 3G with 2G.

3GDR_RNC17_Scrip
t.txt

5. Script for MBC site:

MBC_2263&5589_S
cript.txt

6. End the overlaid and underlaid subcell command.


RXTCE=MO=RXOTG-XXX,CELL=A0000A,CHGR=1;
RLLLC:CELL=A0000A,SCLD=OFF;
RLSLE:CELL=A0000A,PERM;
RLGSC:CELL=A0000A,SCALLOC=UL;
RLDGE:CELL=A0000A,CHGR=1;
RLDSE:CELL=A0000A;

61
9 FAULT CODE LIST

Below is the common fault code list for RBS6000.

Fault List RBS


6000.xls

62