Error
Error Description Source Possible Solutions
Code
1 Invalid Command
2 Parameter Block
Error
3 Return Block Error
4 Out Of Memory 1) Close all other programs
2) Increase system RAM
3) Increase virtual memory
5 Invalid Parameter An invalid value was supplied to a 1) Ensure parameters being passed to DLL
function files are of the correct type
6 Math Domain Error An attempt was made to perform 1) Examine waveform analysis steps for a
an invalid math operation in a non- possible division by zero. For example, finding
calculator step. the slope of a waveform with a near infinite
slope.
7 Math Singularity
Error
8 Math Overflow Error
9 Math Underflow Error
10 Math Total Loss of
Significance Error
11 Math Partial Loss of
Significance Error
12 ACL Math Error
13 Communications A communications error occurred 1) Examine the serial cable link a poor
Error on the COM port. connection or faulty cable
2) Ensure COM port settings are equivalent
within InspeXion and the other device
14 Function Aborted
15 Busy An attempt was made, using a 1) Use a visual indication on the display (either
menu button, to run a sequence an Indicator or text message) to clearly identify
while another sequence was when a sequence is running
running.
16 Unsupported Option
17 No Data Available
1000 Invalid Mode The hardware mode requested is 1) Refer to the InspeXion manual and
not supported by the selected applicable hardware manual for specific
board hardware features supported and their
configuration options.
1001 Invalid Range The signal range requested is not 1) Refer to the InspeXion manual and
supported by the selected board. applicable hardware manual for specific
hardware features supported and their
configuration options.
1002 Invalid Channel The channel requested is not 1) Refer to the InspeXion manual and
supported by the selected board. applicable hardware manual for specific
hardware features supported and their
configuration options.
Error
Error Description Source Possible Solutions
Code
Appendix A Error Codes 2
1003 Invalid Channel Type The channel type requested is not 1) Refer to the InspeXion manual and
supported by the selected board. applicable hardware manual for specific
hardware features supported and their
configuration options.
1004 Mode Error The requested command caused 1) Refer to the InspeXion manual and
MODE to become invalid applicable hardware manual for specific
hardware function details
1005 Range Error The requested command caused 1) Refer to the InspeXion manual and
RANGE to become invalid applicable hardware manual for specific
hardware function details
1006 Channel Error The requested command caused 1) Refer to the InspeXion manual and
CHANNEL to become invalid applicable hardware manual for specific
hardware function details
1007 Board Not The specified hardware module is 1) Verify all hardware connections are secure
Responding not accessible 2) Refer to the InspeXion manual and
applicable hardware manual for other trouble
shooting ideas
1008 Signal Over-range One of the input signals exceeded 1) Increase the voltage range setting for the
its selected voltage range during a channel
GetData sequence step. 2) Use a voltage dividing circuit to bring the
voltage signal within the specified range
1009 Overflow Error
1010 Timeout Error A sequence step was waiting for 1) Increase the timeout setting
an event that did not occur in the 2) Ensure the event being monitored is
specified timeout period. A timeout occurring
length is required in GetData and
Serial Input sequence steps.
1011 Cannot Write to Input An attempt was made to change
the value of an input which is not
editable
1012 Pre-scale Out Of Master clock pre-scale out of
Range range
1013 Envelope Out Of Envelope out of range 1) Review envelopes to ensure all waveforms
Range are valid
1014 Channel In Use Channel currently in use
1015 CHM Checksum
Error
1016 CHM Shunt Cal Error
1017 CHM Power Supply Power rail error 1) Ensure power supply is operating normally
Error
1018 Retry Error Max transmission retries failed. 1) Restart MMI
2) Reboot system
1019 Not a Bridge Device An attempt to perform a bridge
device operation on a non bridge
device was made
1020 Device Not Settling Timeout waiting for a value to
settle
1021 Offset Error
Error
Error Description Source Possible Solutions
Code
1022 Calibration Error
Appendix A Error Codes 3
Failure
1054 Genius Illegal Invalid Message Parameter
Message
1055 Genius Device is
Offline
1056 Genius Invalid Invalid Network/Device Address
Network Address
1057 Genius Failure PCIM failed, watchdog timed out
Watchdog Timeout (727MS)
1058 Failure Installing
Memory I/O VxD
1059 Attempt to Un-Frame Attempt to extract message from
an Invalid DF1 invalid DF1 framed message
Message
1060 Incomplete DF1 The DF1 framed message is
Framed Message incomplete (i.e. missing end
delimiters)
1061 Transmit Buffer
Overrun
1062 Receive Error
1063 No Handshake
Received For DF1
Message
1064 No Response
Received For DF1
Message
1065 Load Scanner Library Device Net Error
Failed
1066 Invalid Library for Device Net Error
Scanner Functions
1067 Load Error Library Device Net Error
Failed
1068 Invalid Library for Device Net Error
Error Functions
list
1078 Timeout Device Net Error
1079 Error opening UCMM Device Net Error
connection
1080 Master/Slave Device Net Error
connection set is
busy
1081 Error allocating Device Net Error
Master/Slave
connection set
1082 Device Vendor Id Device Net Error
mismatch
1083 Error reading Device Device Net Error
Vendor Id
1084 Device Product Type Device Net Error
mismatch
1085 Error reading Product Device Net Error
Type
1086 Device Product Code Device Net Error
mismatch
1087 Error reading Product Device Net Error
Code
1088 Invalid I/O 1 Device Net Error
connection input size
1089 Error reading I/O 1 Device Net Error
connection input size
1090 Invalid I/O 1 Device Net Error
connection output
size
1091 Invalid I/O 1 Device Net Error
connection output
size
1092 Invalid I/O 2 Device Net Error
connection input size
1093 Error reading I/O 2 Device Net Error
connection input size
1094 Invalid I/O 2 Device Net Error
connection output
size
1095 Invalid I/O 2 Device Net Error
connection output
size
1096 Error setting I/O 1 Device Net Error
connection EPR
Error
Error Description Source Possible Solutions
Code
1097 Error setting I/O 2 Device Net Error
connection EPR
Appendix A Error Codes 6
1136 Channel not The software has detected a 240 1) The 240 is wired properly (Check that
responding to module configuration problem or Benchmate jumpers ON and a wire jumper
commands. the 240 is disabled. from output 3 to input 4).
2) The 240 is functioning properly (check the
power LED, perform a diagnostic on a timer)
3) The internal timer setting for the 240 is not
set correctly (in software).
1137 Zero self-cal offset
out of spec
1138 Slope self-cal range
out of spec
(saturated)
1139 WinRt driver failed to Ensure Device Installer has been run and the
open drivers are loaded for the hardware
1140 Memory failed to map
Error
Error Description Source Possible Solutions
Code
1152 Fail to stop timer
5002 FIFO is empty An attempt to read in data was 1) Double check data collection routine to
made but no data was available. ensure data will be collected.
2) Ensure that the waveform being referenced
is being assigned data
5003 FIFO has overrun;
data has been lost
5004 Some FIFO data has
been initialized
5005 Mdata initialized with
too much data.
5006 Mdata initialized with
too little data.
5007 An Attempt to Modify
and Existing File Of
Incorrect Type
5008 Read/writer error of
MData save.
5009 The index for
retrieval is out of the
file range.
5010 An end of file
occurred.
5011 Cannot open the file.
5012 Attempt to overwrite
a file with more than
one record (i.e. one
previously opened in
the APPEND mode).
5013 An existing Check if the file is read-only.
LL_BinDisk file
cannot be
overwritten.
5014 MData size does not
match a file MData
constant size.
5015 MData record has
been deleted
5016 Too many columns
for the input array
Error
Error Description Source Possible Solutions
Code
5017 Too few columns for
the input array
5018 Cannot have zero
length string in the
"key" column
5019 Cannot have a string
in a numeric field
5020 Cannot have
duplicate keys in an
Appendix A Error Codes 11
input array
A-1