Sunteți pe pagina 1din 18

Appendix A Error Codes 1

Error
Error Description Source Possible Solutions
Code
1 Invalid Command
2 Parameter Block
Error
3 Return Block Error
4 Out Of Memory 1) Close all other programs
2) Increase system RAM
3) Increase virtual memory
5 Invalid Parameter An invalid value was supplied to a 1) Ensure parameters being passed to DLL
function files are of the correct type
6 Math Domain Error An attempt was made to perform 1) Examine waveform analysis steps for a
an invalid math operation in a non- possible division by zero. For example, finding
calculator step. the slope of a waveform with a near infinite
slope.
7 Math Singularity
Error
8 Math Overflow Error
9 Math Underflow Error
10 Math Total Loss of
Significance Error
11 Math Partial Loss of
Significance Error
12 ACL Math Error
13 Communications A communications error occurred 1) Examine the serial cable link a poor
Error on the COM port. connection or faulty cable
2) Ensure COM port settings are equivalent
within InspeXion and the other device
14 Function Aborted
15 Busy An attempt was made, using a 1) Use a visual indication on the display (either
menu button, to run a sequence an Indicator or text message) to clearly identify
while another sequence was when a sequence is running
running.
16 Unsupported Option
17 No Data Available
1000 Invalid Mode The hardware mode requested is 1) Refer to the InspeXion manual and
not supported by the selected applicable hardware manual for specific
board hardware features supported and their
configuration options.
1001 Invalid Range The signal range requested is not 1) Refer to the InspeXion manual and
supported by the selected board. applicable hardware manual for specific
hardware features supported and their
configuration options.
1002 Invalid Channel The channel requested is not 1) Refer to the InspeXion manual and
supported by the selected board. applicable hardware manual for specific
hardware features supported and their
configuration options.
Error
Error Description Source Possible Solutions
Code
Appendix A Error Codes 2

1003 Invalid Channel Type The channel type requested is not 1) Refer to the InspeXion manual and
supported by the selected board. applicable hardware manual for specific
hardware features supported and their
configuration options.
1004 Mode Error The requested command caused 1) Refer to the InspeXion manual and
MODE to become invalid applicable hardware manual for specific
hardware function details
1005 Range Error The requested command caused 1) Refer to the InspeXion manual and
RANGE to become invalid applicable hardware manual for specific
hardware function details
1006 Channel Error The requested command caused 1) Refer to the InspeXion manual and
CHANNEL to become invalid applicable hardware manual for specific
hardware function details
1007 Board Not The specified hardware module is 1) Verify all hardware connections are secure
Responding not accessible 2) Refer to the InspeXion manual and
applicable hardware manual for other trouble
shooting ideas
1008 Signal Over-range One of the input signals exceeded 1) Increase the voltage range setting for the
its selected voltage range during a channel
GetData sequence step. 2) Use a voltage dividing circuit to bring the
voltage signal within the specified range
1009 Overflow Error
1010 Timeout Error A sequence step was waiting for 1) Increase the timeout setting
an event that did not occur in the 2) Ensure the event being monitored is
specified timeout period. A timeout occurring
length is required in GetData and
Serial Input sequence steps.
1011 Cannot Write to Input An attempt was made to change
the value of an input which is not
editable
1012 Pre-scale Out Of Master clock pre-scale out of
Range range
1013 Envelope Out Of Envelope out of range 1) Review envelopes to ensure all waveforms
Range are valid
1014 Channel In Use Channel currently in use
1015 CHM Checksum
Error
1016 CHM Shunt Cal Error
1017 CHM Power Supply Power rail error 1) Ensure power supply is operating normally
Error
1018 Retry Error Max transmission retries failed. 1) Restart MMI
2) Reboot system
1019 Not a Bridge Device An attempt to perform a bridge
device operation on a non bridge
device was made
1020 Device Not Settling Timeout waiting for a value to
settle
1021 Offset Error
Error
Error Description Source Possible Solutions
Code
1022 Calibration Error
Appendix A Error Codes 3

1023 System temperature is too hot


1024 The RTC CMOS battery has
expired
1025 KTX Dual Port Error
1026 KTX 16 Bit Error
1027 KTX RAM Error
1028 KTX CTC Error
1029 KTX SIO Error
1030 KTX Load Protocol
CRC Error
1031 KTX Invalid Interface
1032 KTX Invalid Node
1033 KTX Invalid Baud
Rate
1034 KTX Invalid Protocol
1035 KTX Not Responding
1036 KTX Local TX Error
1037 KTX Remote TX
Error
1038 KTX Duplicate Node
1039 KTX Illegal
Command
1040 KTX Invalid Address
1041 KTX No Receive
Packet
1042 KTX Incorrect
Receive TNS
1043 KTX Invalid
Parameter
1044 Genius Invalid
Network Number
1045 Genius Device
Network Failure
1046 Genius Invalid I/O Invalid PCIM I/O Port (SW1), LEDs
Port off
1047 Genius Invalid Invalid PCIM Memory (SW2/3),
Memory Address LEDs off
1048 Genius Failure No PCIM failed, heartbeat/voltage off
Heartbeat
1049 Genius Message Too Exceeds data length of device
Long
1050 Genius No Datagram
Available
1051 Genius Busy Card Processing, command not
completed
Error
Error Description Source Possible Solutions
Code
1052 Genius Bus Timeout Transmit Reply not completed in
10 sec
1053 Genius Transmit Transmit Message Failure
Appendix A Error Codes 4

Failure
1054 Genius Illegal Invalid Message Parameter
Message
1055 Genius Device is
Offline
1056 Genius Invalid Invalid Network/Device Address
Network Address
1057 Genius Failure PCIM failed, watchdog timed out
Watchdog Timeout (727MS)
1058 Failure Installing
Memory I/O VxD
1059 Attempt to Un-Frame Attempt to extract message from
an Invalid DF1 invalid DF1 framed message
Message
1060 Incomplete DF1 The DF1 framed message is
Framed Message incomplete (i.e. missing end
delimiters)
1061 Transmit Buffer
Overrun
1062 Receive Error
1063 No Handshake
Received For DF1
Message
1064 No Response
Received For DF1
Message
1065 Load Scanner Library Device Net Error
Failed
1066 Invalid Library for Device Net Error
Scanner Functions
1067 Load Error Library Device Net Error
Failed
1068 Invalid Library for Device Net Error
Error Functions

1069 Load Hardware Device Net Error


Driver Library Failed
1070 Open Card Failed Device Net Error
1071 Go Online Failed Device Net Error
1072 Start Scan Failed Device Net Error
1073 Add Device Failed Device Net Error
1074 Get Device Status Device Net Error
Failed
1075 Get Device Event Device Net Error
Failed
Error
Error Description Source Possible Solutions
Code
1076 Read Device I/O Device Net Error
Failed
1077 Device not in scan Device Net Error
Appendix A Error Codes 5

list
1078 Timeout Device Net Error
1079 Error opening UCMM Device Net Error
connection
1080 Master/Slave Device Net Error
connection set is
busy
1081 Error allocating Device Net Error
Master/Slave
connection set
1082 Device Vendor Id Device Net Error
mismatch
1083 Error reading Device Device Net Error
Vendor Id
1084 Device Product Type Device Net Error
mismatch
1085 Error reading Product Device Net Error
Type
1086 Device Product Code Device Net Error
mismatch
1087 Error reading Product Device Net Error
Code
1088 Invalid I/O 1 Device Net Error
connection input size
1089 Error reading I/O 1 Device Net Error
connection input size
1090 Invalid I/O 1 Device Net Error
connection output
size
1091 Invalid I/O 1 Device Net Error
connection output
size
1092 Invalid I/O 2 Device Net Error
connection input size
1093 Error reading I/O 2 Device Net Error
connection input size
1094 Invalid I/O 2 Device Net Error
connection output
size
1095 Invalid I/O 2 Device Net Error
connection output
size
1096 Error setting I/O 1 Device Net Error
connection EPR
Error
Error Description Source Possible Solutions
Code
1097 Error setting I/O 2 Device Net Error
connection EPR
Appendix A Error Codes 6

1098 Master/Slave Device Net Error


connection set synch
fault
1099 Driver loaded Device Net Error
1100 Driver not found Device Net Error
1101 Invalid driver Device Net Error
1102 Driver not loaded Device Net Error
1103 Command timeout Device Net Error
1104 General failure Device Net Error
1105 Command error Device Net Error
1106 Invalid MAC Id Device Net Error
1107 Invalid baud rate Device Net Error
1108 Duplicate MAC Id Device Net Error
1109 Duplicate device Device Net Error
1110 No device present Device Net Error
1111 Device is Offline Device Net Error
1112 Device is active Device Net Error
1113 Device is not Offline Device Net Error
1114 Error scanning Device Net Error
1115 Error not scanning Device Net Error
1116 Scanner is Offline Device Net Error
1117 Illegal I/O offset Device Net Error
1118 Bus fault Device Net Error
1119 Unknown error Device Net Error
1120 Invalid area Device Net Error
1121 Not in device list Device Net Error
1122 Invalid event Device Net Error
1123 Invalid event Device Net Error

1124 Invalid data size Device Net Error

1125 Connection does not Device Net Error


exist
1126 Invalid class Device Net Error
1127 Invalid instance Device Net Error

1128 Explicit message not Device Net Error


available
1129 Explicit message Device Net Error
pending
1130 Unsupported Device Net Error
connection type
Error
Error Description Source Possible Solutions
Code
1131 Invalid connection Device Net Error
flags
1132 Explicit message Device Net Error
truncated
Appendix A Error Codes 7

1133 Not registered Device Net Error

1134 Event registered Device Net Error

1135 Invalid device Id Device Net Error

1136 Channel not The software has detected a 240 1) The 240 is wired properly (Check that
responding to module configuration problem or Benchmate jumpers ON and a wire jumper
commands. the 240 is disabled. from output 3 to input 4).
2) The 240 is functioning properly (check the
power LED, perform a diagnostic on a timer)
3) The internal timer setting for the 240 is not
set correctly (in software).
1137 Zero self-cal offset
out of spec
1138 Slope self-cal range
out of spec
(saturated)
1139 WinRt driver failed to Ensure Device Installer has been run and the
open drivers are loaded for the hardware
1140 Memory failed to map

1141 Fail to write in the


registry
1143 Invalid device name
1144 Number of sections
are out of range
1145 Could Not Open
Service Manager
1146 Fail to start the
service
1147 Fail to stop the
service
1148 Fail to load WinRt
VXD
1149 Fail to unload WinRt
VXD
1150 Fail to setup timer

1151 Fail to start timer

Error
Error Description Source Possible Solutions
Code
1152 Fail to stop timer

1153 Fail to read registry

1154 Fail to open registry


Appendix A Error Codes 8

1155 The specified device


not installed
1156 GFB source not
available
1157 Slope self-cal range
out of spec (too low)
1158 Internal reference ee
value out of spec
1159

1161 Timed out waiting for


configuration mode
1161 Timed out waiting for
run mode
1162 Timed out waiting for
command result
1163 Command returned
with a fail code
1164 Timed out waiting for
BUSY to clear
1165 Trigger queue is full

1166 Timed out waiting for


open connection
1167 Invalid index to
trigger queue
1168 Invalid index to event
queue
1169 Trigger returned with
a fail code
1170 Unable to allocate
memory
1171 UCS module is not
configured to support
selected I/O data
type
1172 Interrupt chosen is
not supported by
Sciemetric's UCS
carrier card
Error
Error Description Source Possible Solutions
Code
1173 UCS module was not
found at the selected
port address
1174 The UCS module has
not been successfully
initialized
1175 The UCS module is
in configuration mode
Appendix A Error Codes 9

1176 The UCS module is


not in configuration
mode
1177 The channel number
selected is not in the
valid range
1178 The data in the
receive buffer is not
valid (network is not
transmitting data)
1179 A given parameter
does not have a valid
value
1180 Data cannot be
transmitted due to a
network fault
1181 Windows device
driver not running
1182 Windows device
driver error
1183 The UCS module has
been previously
initialized.
1184 Sample rate exceeds
the boundaries
2000 Invalid Cluster
2001 Invalid Cluster Type
2002 Invalid Module A hardware module specified in the 1) Ensure all hardware specified in the
Hardware Table could not be hardware table is present or not referenced
detected or caused an error. anywhere in the SPX.
2) Ensure all hardware is powered (check
power LED's and fuses)
3) Perform IDE diagnostics on the
inputs/outputs that utilize the hardware module
2003 Invalid Module Type
2004 Invalid Handle
2005 Cluster Not Unique
2006 Module Not Unique
Error
Error Description Source Possible Solutions
Code
2007 Channel Not Unique The channel is used by more than 1) Verify that all inputs and outputs are
one configured input and/or output assigned to unique channels.
5000 Invalid Data Type InspeXion does not recognize the
data it has received.
5001 FIFO is full Data could not be removed from 1) Decrease the data collection rate and/or
the data buffer at a quick enough duration
rate. The data buffer is full. 2) Decrease the number of channels collected
Appendix A Error Codes 10

5002 FIFO is empty An attempt to read in data was 1) Double check data collection routine to
made but no data was available. ensure data will be collected.
2) Ensure that the waveform being referenced
is being assigned data
5003 FIFO has overrun;
data has been lost
5004 Some FIFO data has
been initialized
5005 Mdata initialized with
too much data.
5006 Mdata initialized with
too little data.
5007 An Attempt to Modify
and Existing File Of
Incorrect Type
5008 Read/writer error of
MData save.
5009 The index for
retrieval is out of the
file range.
5010 An end of file
occurred.
5011 Cannot open the file.
5012 Attempt to overwrite
a file with more than
one record (i.e. one
previously opened in
the APPEND mode).
5013 An existing Check if the file is read-only.
LL_BinDisk file
cannot be
overwritten.
5014 MData size does not
match a file MData
constant size.
5015 MData record has
been deleted
5016 Too many columns
for the input array
Error
Error Description Source Possible Solutions
Code
5017 Too few columns for
the input array
5018 Cannot have zero
length string in the
"key" column
5019 Cannot have a string
in a numeric field
5020 Cannot have
duplicate keys in an
Appendix A Error Codes 11

input array

5021 A "link" must be a


previously defined
"key"
5022 A "link" must not not
link to a row with
another "link"
5023 No "key" found and
no default key.
5024 Cannot resize a
register
5025 Cannot open
directory
5026 The file is corrupt
5027 Envelope could not
be created due to file
errors
6000 No script present
6001 "Data Overrun" A GetData step attempted to 1) Decrease the data collection rate
collect data at a rate that exceeded 2) Decrease the number of channels collected
the software and/or hardware's
capability.
6002 Attempt to add a
NULL script record
into a script
6003 Attempt to add a
NULL task into a
script
6004 Attempt to add a task
to a script with no
data
6005 Attempt to add/move
a task to a script at
an invalid record
number
6006 Invalid Start Trigger
6007 Invalid Stop Trigger
6008 Invalid Sensor
6009 Finished
6010 Stop Trigger
Error
Error Description Source Possible Solutions
Code
6011 Invalid Timer
6012 Start is Before Data
6013 Start is After Data
6014 End is Before Data
6015 End is After Data
6016 Start and End
Reversed
6017 Invalid Effector
Appendix A Error Codes 12

6018 LUT Record Not The sequence step to write back to


Found a lookup table failed because the
key was not found and row
addition was not enabled.
6019 Invalid Speed A GetData step failed because the
interval to collect at was zero.
6020 Invalid Length A GetData step failed because the
number of points to collect was
less than or equal to zero.
7000
7001 An invalid filter
argument was
attempted.
7002 A filter coefficient is
approaching infinity
7003 Invalid Equation
7004 Equation Too Long
7005 Null Equation
7006 Unmatched
Parenthesis in
Equation
7007 Misplaced Function
In Equation
7008 Misplaced Decimal in
Equation
7009 Misplaced Operand
in Equation
7010 Misplaced Unary
Operator in Equation
7011 Misplaced Label in
Equation
7012 Invalid Token
7013 Missing Operand in
Equation
7014 Missing Symbol in
Equation
7015 Missing Operand
Before
Error
Error Description Source Possible Solutions
Code
7016 Division By Zero
within an equation
7017 Expression Cannot
be Empty
7018 Incorrect Number of
Values in an Equation
7019 Invalid Expression in
an Equation
Appendix A Error Codes 13

7020 Invalid Operator in an


Equation
7021 Function is Missing
Parameters
7022 Math Domain Error in
Equation
7023 Logical Operator
Missing in Operand
in Equation
7024 Comparison Operator
Missing Operand
7025 Invalid Order
7026 Invalid Frequency
7027 Invalid Interval
7028 Invalid Ripple
7029 Invalid Filter
8000 Band Width Error
8001 Resampling Size
Error
9000 Invalid Feature Type
9001 Invalid Feature X0X1 A sequence step requiring a start
and stop point (such as a window
in a signature step) has a start
point after a stop point.
9002 Invalid Parm Block
No data to generate
9003 template
Envelope delta X is
9004 invalid
9005 Threshold count < 1

11000 Record Not Found


11001 Invalid File
11002 No File
11003 Write Error
11004 Not Unique
11005 File Remove Error
Error
Error Description Source Possible Solutions
Code
11006 Incorrect Element
Count
11007 Missing Element
11008 Invalid Buffer Length
11009 Missing Cluster
11010 Missing Module
11011 Invalid Module
Configuration
11012 Invalid Cluster
Configuration
Appendix A Error Codes 14

11013 Invalid Data


Configuration
11014 Permanent Record
11015 Record In Use
11016 Invalid Model
Number
11017 CRC Error
11018 Invalid Request
17000 Cannot Reset Lana
17001 Cannot Create
Receive Session
17002 Cannot Create Send
Session
17003 Receive Error
17004 Send Error
17005 Invalid Receive Data
17006 Invalid Send Data
17007 Netbios Invalid Buffer
17008 Netbios Invalid
Command
17009 Netbios Command
Timed Out
17010 NetBios Incomplete
Receive Message
17011 Netbios Local No
Acknowledge
Command Failed
17012 Netbios Invalid Local
Session Number
17013 Netbios No Resource
Available
17014 Netbios Session has
Been Closed
17015 Netbios Command
Cancelled
Error
Error Description Source Possible Solutions
Code
17016 Netbios Duplicate
Name In Table
17017 Netbios Name Table
Full
17018 Netbios Name
Deregistered
17019 Netbios Local
Session Table Full
17020 Netbios No Listen
Outstanding Error On
Open Session.
Appendix A Error Codes 15

17021 Netbios Illegal Name


Number
17022 Netbios No Answer
17023 Netbios name Not
Found
17024 Netbios name in Use
On Remote Adapter
17025 Netbios Name
Deleted
17026 Netbios Abnormal
Session End
17027 Netbios Name
Conflict
17028 Netbios Incompatible
Remote Device
17029 Netbios Interface
Busy
17030 Netbios Too Many
Commands
Outstanding
17031 Netbios Invalid Lana
Number
17032 Netbios Command
Completed During
Cancel
17033 Netbios Reserved
Name For Add Group
17034 Netbios Command
Not Valid To Cancel
17035 Netbios System Error
17036 Netbios Remote Hot
Carrier Detected
17037 Netbios Local Hot
Carrier Detected
17038 Netbios No Carrier
Detected
Error
Error Description Source Possible Solutions
Code
17039 Netbios Adapter
Malfunction
17040 Netbios Error on
Implicit Dir Initialize
17041 Netbios Error on
Implicit Dir Open
Adapter
17042 Netbios Adapter
Check
17043 Netbios Not Loaded
Appendix A Error Codes 16

17044 Netbios Open


Parameter Invalid
17045 Netbios Unexpected
Adapter Close
17046 Netbios Command
Pending Status
17047 Netbios Unknown
Error
17048 Out of Low DOS
Memory
19000 Invalid DLL Mode
19001 Invalid DLL Channel
19002 Invalid DLL Range
19003 DLL Mode Error
19004 DLL Channel Error
19005 DLL Range Error
19006 DLL Cannot Be
Loaded Or Cannot
Be Found
19007 DLL Address Error

19008 DLL Thread


Initialization Error
19009 DLL Device
Initialization Error
19010 DLL Device Not
Fount
19011 DLL Timed Out
19012 DLL Function
Mapping Error
19013 Illegal DLL Process
Number
19014 Error Closing DLL
Thread
19015 DLL Process Error
Error
Error Description Source Possible Solutions
Code
19016 Error Initializing DLL

20000 Serial Number must


not be blank
20001 Model Number must
not be blank
Index 17
Appendix A Error Codes 1

A-1

S-ar putea să vă placă și