Sunteți pe pagina 1din 4

LOGIN (/USER/LOGIN) CART (/CART) Search...

Engineering ANSYS Software Resource ANSYS About News & Contact


Consulting & Support Library Training Us Insights Us
(/engineering- (/ansys-software- (/resources) (/ansys- (/about- (/news- (/contact-
(/) consulting) support) training) us) insights) us)

you are here: (/) / News & Insights (/news-insights) / Engineering Advantage Blog (/blog) / Plasticity Simulation Tips & Tricks

Engineering Advantage Subscribe to Our Blog via Email:


(http://www.linkedin.com/shareArticle?
(http://twitter.com/intent/tweet?
(http://www.facebook.com/share.php?
SUBSCRIBE ME!

Plasticity Simulation Tips & Tricks mini=true&url=caeai.com//blog/plasticity-

simulation-
status=Plasticity
u=caeai.com//blog/plasticity-

Simulation
simulation-

tips- (https://plus.google.com/share?
Tips & tips-
Related Posts:
tricks&title=Plasticity
url=caeai.com//blog/plasticity-
Tricks+caeai.com//blog/plasticity-
tricks&title=Plasticity

Simulation
simulation-
simulation-
Simulation

Tips & tips- tips- Tips & (/blog-

August 14, 2015 By: Peter Barrett Share: Tricks) tricks) tricks) Tricks) rss)

Linear elastic material modeling is an excellent assumption for structures that undergo small
deformations and return to their original shape upon removal of load. Using an elastic
modulus and Poisson's ratio for the initial simulation is a good practice for all analyses (/blog/structural-thermal-and-cfd-simulation-
medical-devices)
(/engineering-consulting/fea-services/fea-consultants-approach) , since it solves in a single iteration and
provides benchmark stress results. However, many materials undergo permanent
deformation, even under design load conditions, which make the linear assumption invalid.
With metallic structures, permanent deformations will occur when the Von Mises yield stress
August 16, 2017
is exceeded, and the resulting plastic strains can often become significant.
by: Chris Mesibov

The permanent displacements are a result of the dissipation of energy and are irreversible, Structural, Thermal and CFD
which makes the event path dependent. Thus, analytical simulations require the load Simulation for Medical Devices
stepping to follow the real loading sequence. Although the theory of plasticity grew out of the (/blog/structural-thermal-and-cfd-
study of metals, one can often apply bilinear or multi-linear isotropic hardening laws to many simulation-medical-devices)
other materials, as long as the underlying theory and analysis is applicable.
READ MORE (/BLOG/STRUCTURAL-THERMAL-AND-CFD-
SIMULATION-MEDICAL-DEVICES)
Plasticity modeling can be subdivided into:

Loadings that induce only small plastic strains, which are roughly the same order as the TAGS: medical product development (/blog?
elastic strains, where cyclic loading and a kinematic hardening law should be utilized. tid_1=medical product development) / FEA Consulting
(/blog?tid=66) / CFD (/blog?tid=80) / CFD Consulting
Very large strains and deformations, so large that the elastic strains can be disregarded
(/blog?tid=81) / Engineering Analysis Tips (/blog?tid=28)
and ultimate capacity is typically the design concern, where an isotropic hardening law is / FEA (/blog?tid=65) / ANSYS (/blog?tid=79)
needed.

Plastic deformations can also be either rate independent or rate dependent, but this blog is
limited to rate independent discussions. A typical plasticity material response of stress vs.
strain (equal to force vs. displacement for a tensile test) is illustrated in Figure 1.
Figure 1 Uniaxial Stress (Force) vs. Strain (Displacement) Response

(/blog/simulation-benefits-healthcare-industry-
electrical-medical-devices)

August 8, 2017
In nearly all FEA software (/ansys-software-support/ansys-software) , the three-dimensional stress
by: Chris Mesibov
state is converted for purposes of material yield evaluation to an equivalent uniaxial stress
state using the Von Mises Yield Criterion. Simulation Benefits For The
Healthcare Industry - Electrical
Medical Devices
(/blog/simulation-benefits-
healthcare-industry-electrical-
When large displacements are active, the finite element analysis (/engineering-consulting/fea- medical-devices)
consulting-services) accounts for the reduction in cross-sectional area under increased load.
Thus the material model must be consistent with this change in geometry. This is achieved by READ MORE (/BLOG/SIMULATION-BENEFITS-HEALTHCARE-
INDUSTRY-ELECTRICAL-MEDICAL-DEVICES)
converting nominal stress and engineering strain data typically output from a tensile test into
true stress and log strain values utilizing the following formulas.
TAGS: healthcare (/blog?tid_1=healthcare) /
Electromagnetics (/blog?tid=303) / FEA Consulting
(/blog?tid=66) / CFD (/blog?tid=80) / CFD Consulting
(/blog?tid=81) / FEA (/blog?tid=65)
Often, the input needed for a multilinear stress-strain law requires the true stress vs. plastic
strain instead of the total strain described above. In this case, the first data point should be
zero strain and the yield stress. A common mistake made in entering the remaining plastic
strain data is subtracting only the yield strain instead of correctly accounting for the material
hardening by subtracting the full elastic strain component which is equal to the true stress
data point divided by the modulus of elasticity. A simple spreadsheet is often the easiest
manner to achieve this conversion as shown in Figure 2.

Figure 2 - Spreadsheet Conversion of Tensile Test Data Into FEA Input

(/blog/simulation-benefits-healthcare-industry-
fda-approval)
August 1, 2017
by: Chris Mesibov

Simulation Benefits For The


Healthcare Industry - FDA
Approval (/blog/simulation-
benefits-healthcare-industry-fda-
approval)

READ MORE (/BLOG/SIMULATION-BENEFITS-HEALTHCARE-


INDUSTRY-FDA-APPROVAL)

TAGS: healthcare (/blog?tid_1=healthcare) / simulation


driven product development (/blog?tid_1=simulation
driven product development) / FDA approval (/blog?
tid_1=FDA approval) / Electromagnetics (/blog?tid=303) /
FEA Consulting (/blog?tid=66) / CFD (/blog?tid=80) /
CFD Consulting (/blog?tid=81) / FEA (/blog?tid=65) /
ANSYS (/blog?tid=79)

(/blog/simulation-benefits-healthcare-industry-
When running the plasticity material response simulation one should also consider: part-1)

Setup the load stepping such that at least two load steps are used where the first load step
can be run up to about 90% of the yield stress in a single step, since no plasticity is
present. (One might need to ramp the load for other nonlinearities present.) This July 25, 2017
magnitude of load can be determined by reviewing the stresses from the linear analysis by: Chris Mesibov
described previously and scaling the loads to get to the 90% level. For the remaining load
steps, be sure to include plenty of intermediate sub-steps to capture convergence and
Simulation Benefits For The
Healthcare Industry - Part 1
track the stress-strain curve accurately. It is important that the plastic strain increment per (/blog/simulation-benefits-
time step stay relatively low because, once plasticity occurs, it cannot be recovered. A healthcare-industry-part-1)
good rule of thumb is 5%, but this is problem and material-dependent.
Make sure that the last point on the stress-strain curve entered is well beyond any READ MORE (/BLOG/SIMULATION-BENEFITS-HEALTHCARE-
numerical strains anticipated since, in most codes, if you "run off the end of the input INDUSTRY-PART-1)

curve" the slope of the stress-strain curve is zero. I usually include a data point of at least
100% strain to assure that this does not occur. Postprocessing can be used to determine TAGS: healthcare (/blog?tid_1=healthcare) / medical
if the material ultimate limit has been reached. product development (/blog?tid_1=medical product
development) / Electromagnetics (/blog?tid=303) / FEA
For large strain problems, plastic strain is generally the most interesting quantity to look at, Consulting (/blog?tid=66) / CFD (/blog?tid=80) / CFD
Consulting (/blog?tid=81) / FEA (/blog?tid=65)
since large changes in strain can occur under minor changes in stress. Make sure you
are looking at the total accumulated plastic strain when load reversal occurs if comparing
solution results to the material stress-strain curve.

What are your lessons learned when modeling plasticity? I would love to hear from others on
your approaches.

1 Comment CAE Associates


1 Login

Sort by Best
Recommend 1 Share
(/blog/tips-tricks-matching-fea-results-physical-
Join the discussion data)

LOG IN WITH
OR SIGN UP WITH DISQUS ?

Name

July 18, 2017


by: Peter Barrett
Ruben Ruiz 3 months ago
How load should be applied? incremental cyclic load? Tips & Tricks for Matching FEA
Reply Share Results to Physical Data
(/blog/tips-tricks-matching-fea-
results-physical-data)
Subscribe d Add Disqus to your siteAdd DisqusAdd Privacy

READ MORE (/BLOG/TIPS-TRICKS-MATCHING-FEA-


RESULTS-PHYSICAL-DATA)

TAGS: test data (/blog?tid_1=test data) / FEA


Consulting (/blog?tid=66) / Engineering Analysis Tips
(/blog?tid=28) / FEA (/blog?tid=65)

Contact Us (/contact-us) Privacy Policy (/about-us/privacy-policy) Sitemap (/sitemap) 2017 CAE Associates Inc. All rights reserved (/) (http://www.linkedin.com/company/computer-
aided-
engineering-
associates-
inc.?
(/feed)
(https://plus.google.com/b/107351817128594420045/10735
trk=company_logo)
(http://www.youtube.com/caeai)
(http://www.twitter.com/caeainc)
(http://www.facebook.com/caeai)

S-ar putea să vă placă și