Sunteți pe pagina 1din 14

Alcatel-Lucent OmniPCX Enterprise

Communication Server

NX64
Legal notice:

Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of


Alcatel-Lucent. All other trademarks are the property of their respective
owners.

The information presented is subject to change without notice.

Alcatel-Lucent assumes no responsibility for inaccuracies contained herein.

Copyright 2012 Alcatel-Lucent. All rights reserved.

The CE mark indicates that this product conforms to the following Council
Directives:
- 2004/108/EC (concerning electro-magnetic compatibility)
- 2006/95/EC (concerning electrical safety)
- 1999/5/EC (R&TTE)


  

Chapter 1
Hardware description

 Presentation ............................................................................................. 1.1


 Environment ............................................................................................. 1.1
 Functional environment ................................................................................. 1.1
 Inputs/Outputs ............................................................................................... 1.2
 Functional blocks ................................................................................... 1.3
 List ................................................................................................................. 1.3
 Blocks description .......................................................................................... 1.4

Chapter 2
Hardware configuration

 Reference .................................................................................................. 2.1


 Overview .................................................................................................... 2.1
 Strappings ................................................................................................ 2.1
 Meaning of the LED ............................................................................... 2.2

Chapter 3
External connections

 0-1


 Connection ............................................................................................... 3.1


 Output pins ............................................................................................... 3.1

0-2 

 

  
  

1.1 Presentation
The NX64 board is a synchronous serial link controller used to increase system network
capability. It allows routers to be connected to the system via high speed links (up to 1920
kbit/s).
The NX64 board configuration is described in the NX64 - Hardware configuration .
The NX64 board connection is described in the NX64 - External connections .

1.2 Environment

1.2.1 Functional environment


The NX64 board manages four X24/V11 interfaces. The four serial ports on the board are only
used in DCE mode.
Each port can be configured separately with the following rates available : 64, 128, 256, 384,
512, 1024, 1536 or 1920 kbit/s.
The NX64 board converts the data from the router at the continuous rate of Nx64 kbit/s into
time slots (32 x 64 kbit/s rate). The frame formed in this way, carried on the board by a IPCM
link, is compatible with the links used within the system (type 1 link).







   
   

    !!"# 1-1


Chapter 1   !!"#

Figure 1.1: NX64 board environment

1.2.2 Inputs/Outputs

1-2 





   
   

    !!"#


  !!"#

Figure 1.2: NX64 board inputs/outputsdiagram

1.3 Functional blocks

1.3.1 List
The NX64 board includes the following parts :
- X24/V11 interface,
- rate adapter,
- clock module,
- common part,
- power supply.







   
   

    !!"# 1-3


Chapter 1   !!"#

Figure 1.3: NX64 board functional summary diagram

1.3.2 Blocks description


1.3.2.1 X24/V11 interface

1-4 





   
   

    !!"#


  !!"#

The interface carries out electrical signal adaptation according to the RS422-A (V11)
recommendation.

Figure 1.4: Interface circuits

1.3.2.2 Rate adapter


This is a TMS 320 C25 signal processor. It processes two X24/V11 ports simultaneously and
controls a buffer used as interface between the IPCM link and X24/V11 link. The data, in
continuous flow on X24/V11, are inserted on the IPCM 125s 32TS frame.
The 30 TS of the IPCM (30 channels at 64 kB/s) are used to carry the data from the X24/V11
link in maximum configuration (1920 kbit/s).
More generally, in the case of an X24/V11 link at N x 64 kB/s, the data are carried on the
board by N TS of IPCM.
1.3.2.3 Clock module
This generates the clocks (Nx64 KHz) used by the protocol controller and rate adapter. The
system clock (16 MHz) is extracted from the backplane.
1.3.2.4 Common part
The common part interfaces the NX64 board with the other system boards. For further details,
refer to the description of the common part (see Common Part - Common part ).
The processor handles the X24/V11 link high level protocol.
1.3.2.5 Power supply
From the -48 V, the converter generates +5 V and +12 V.







   
   

    !!"# 1-5


Chapter 1   !!"#

1-6 





   
   

    !!"#



 

    

2.1 Reference
NX64 board reference : 3BA 23011 AA

2.2 Overview
The diagram below gives the position and number for each strap present on the NX64 board.

Figure 2.1: View of the NX64 board

2.3 Strappings
Ex-factory strappings are shown on grey background.






$%   
   

   "#$!&'!"# 2-1


Chapter 2  "#$!&'!"#

2.4 Meaning of the LED

Figure 2.3: NX64 board front panel


table 2.1: Meaning of the LED
LEDs Meaning
CPU (green LED) CPU activity indicator
BSY (orange LED) Activity indicator of at least one trunk

table 2.2: CPU LED Cadencing


Cadencing Meaning
ON fixed Initialization in progress
100 ms (ON)/ 1s (OFF) Loading in progress
10 ms (ON)/ 10 ms (OFF) Re-flashing boot
300 ms (ON)/ 300 ms (OFF) CPU wait
8 x (900 ms (ON)/ 600 ms (OFF))/1 s (OFF) RAM Test error
8 x (300 ms (ON)/ 600 ms (OFF))/1 s (OFF) Checksum error

2-2 




$%   
   

   "#$!&'!"#

 

     

3.1 Connection
The NX64 board is plugged in an interface position on the ACT shelf.

Figure 3.1: Connection diagram


If the connection is :
- by cable : in this case, the connection to the router is carried out using a NX64 cable (see
NX64 X24/V11 cable - Hardware description ).
- by patch panel (VH cabinet only) : in this case, the connection is carried out using the
patch panel : 32-port, 2-wire module (see Patch Panel - 32 ports module - 32 ports module
).

3.2 Output pins






$    
   

  # "## !"# 3-1


Chapter 3 # "## !"#

Backpanel rear side view


C B A REMARKS
1 GND GND GND
2 TXDAT0n GND TXDAT0p
3 GND GND GND TXDATi, CLKXi, RXDATi,
4 CLKX0n GND CLKX0p CTRLi, INDICi = Signals of ports
X24/V11
5 GND GND GND
6 RXDAT0n GND RXDAT0p
7 CTRL0n GND CTRL0p
8 INDIC0n GND INDIC0p
9 GND GND GND
10 TXDAT1n GND TXDAT1p
11 GND GND GND
12 CLKX1n GND CLKX1p
13 GND GND GND
14 RXDAT1n GND RXDAT1p
15 CTRL1n GND CTRL1p
16 INDIC1n GND INDIC1p
17 GND GND GND
18 TXDAT2n GND TXDAT2p
19 GND GND GND
20 CLKX2n GND CLKX2p
21 GND GND GND
22 RXDAT2n GND RXDAT2p
23 CTRL2n GND CTRL2p
24 INDIC2n GND INDIC2p
25 GND GND GND
26 TXDAT3n GND TXDAT3p
27 GND GND GND
28 CLKX3n GND CLKX3p
29 GND GND GND
30 RXDAT3n GND RXDAT3p
31 CTRL3n GND CTRL3p
32 INDIC3n GND INDIC3p

3-2 




$    
   

  # "## !"#