Protecie termic - calcule

Tj = Rth, total*P +Ta

Rth, total = Rth, JC+Rth, CS+Rth,SA

Pentru NMOS IRF3710:

Tj, max = 175 oC, temperatura maxim jonciune


Rth,JC = 0.75 oC/W, rezisten termic jonciune-capsul
Rth,CS = 0.5 oC/W, rezisten termic capsul-radiator (cu past)
Sthermal_pad 97mm2 = 0.97 cm2 = 0.381 in2
** 1 inch = 2.54 cm

Radiator:

Rth,SA=Rth,rad= 3 oC/W

Past:

conductivitate termic: 1.5 W/m*K


impedan termic: 0.227 oC*in2/W

Rth,CS, past = 0.227/0.381 0.6 oC/W

10^4
** Rth, CS, past = = 9710^61.5 =0.687 oC/W
Ventilator:

80x80x25 [mm]
debit aer: 69,7 m3/h -> 1,16 m3/min
** 1mm = 0.00328 ft
CFM(cubic feet per minute) = 1,16 * 3.283 [ft3/min] = 40,93 [ft3/min]
41 [ft^3/min]
LFM(linear feet per minute)= CFM/S(ft2) = 808010^63.28^2 [^2] =

=595,93 596 ft/min

LFM|factor 0.8 = 476,8 ft/min


factor de corecie pentru Rth, rad+vent : pentru LFM=400 -> 0.378
Rth,rad+vent= 3 oC/W * 0.378 = 1,14 oC/W