Documente Academic
Documente Profesional
Documente Cultură
Issue 04
Date 2016-07-26
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the
customer. All or part of the products, services and features described in this document may not be within the
purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information,
and recommendations in this document are provided "AS IS" without warranties, guarantees or
representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
Website: http://www.huawei.com
Email: support@huawei.com
Contents
2 Overview of Handover................................................................................................................. 8
3 Intra-Frequency Handover.........................................................................................................11
3.1 Overview.......................................................................................................................................................................11
3.1.1 Intra-Frequency Soft Handover................................................................................................................................. 11
3.1.2 Intra-Frequency Hard Handover................................................................................................................................12
3.1.3 Inter RNC Handover..................................................................................................................................................13
3.2 Intra-Frequency Handover Procedure...........................................................................................................................13
3.3 Intra-Frequency Handover Measurement..................................................................................................................... 14
3.3.1 Intra-Frequency Handover Measurement Quantities.................................................................................................14
3.3.2 Intra-Frequency Handover Measurement Events...................................................................................................... 14
3.3.3 Triggering of Event 1A..............................................................................................................................................15
3.3.4 Triggering of Event 1B.............................................................................................................................................. 17
3.3.5 Triggering of Event 1C.............................................................................................................................................. 19
3.3.6 Triggering of Event 1D..............................................................................................................................................20
3.4 Intra-Frequency Handover Decision and Execution.....................................................................................................21
3.5 Follow-up Procedures for Soft Handover Failures.......................................................................................................23
3.5.1 Overview................................................................................................................................................................... 24
3.5.2 Rate Reduction After an SHO Failure....................................................................................................................... 24
3.5.3 D2F Transition After a Soft Handover Failure..........................................................................................................27
3.5.4 E2D Reconfiguration After a Soft Handover Failure................................................................................................ 27
3.6 Signaling Procedures for Intra-Frequency Handover................................................................................................... 28
3.6.1 Intra-NodeB Intra-Frequency Soft Handover Signaling Procedure.......................................................................... 28
3.6.2 Intra-RNC Inter-NodeB Intra-Frequency Soft Handover Signaling Procedure........................................................ 29
3.6.3 Inter-RNC Intra-Frequency Soft Handover Signaling Procedure............................................................................. 30
3.6.4 Intra-RNC Inter-NodeB Intra-Frequency Hard Handover Signaling Procedure....................................................... 32
3.6.5 Inter-RNC Intra-Frequency Hard Handover Signaling Procedure............................................................................ 34
3.7 Addition of Detected Set Cells to the Active Set......................................................................................................... 35
6 Non-Coverage-based Handover............................................................................................... 85
6.1 Load-based Inter-Frequency Handover........................................................................................................................ 86
6.1.1 Load-based Inter-Frequency Handover Procedure.................................................................................................... 86
6.1.2 Load-based Inter-Frequency Handover Measurement.............................................................................................. 86
6.1.3 Load-based Inter-Frequency Handover Decision and Execution.............................................................................. 86
6.2 Load-based Inter-RAT Handover................................................................................................................................. 88
7 HSPA Handover...........................................................................................................................95
7.1 HSDPA Handover.........................................................................................................................................................95
7.1.1 HSDPA Intra-Frequency Handover........................................................................................................................... 95
7.1.2 HSDPA Inter-Frequency Handover........................................................................................................................... 98
7.1.3 HSDPA Inter-RAT Handover.................................................................................................................................. 100
7.2 HSUPA Handover.......................................................................................................................................................100
7.2.1 HSUPA Intra-Frequency Handover......................................................................................................................... 100
7.2.2 HSUPA Inter-Frequency Handover......................................................................................................................... 106
7.2.3 HSUPA Inter-RAT Handover.................................................................................................................................. 109
7.3 HSPA+ Handover....................................................................................................................................................... 109
7.3.1 Overview................................................................................................................................................................. 109
7.3.2 Preselection Phase....................................................................................................................................................110
7.3.3 Fallback Phase......................................................................................................................................................... 110
7.3.4 Retry Phase.............................................................................................................................................................. 110
7.4 Anti-Frequent Serving Cell Change............................................................................................................................111
7.5 HSPA Retry.................................................................................................................................................................111
9 Blind Handover..........................................................................................................................120
9.1 Overview.................................................................................................................................................................... 120
9.2 Triggering of Event 1F............................................................................................................................................... 120
9.3 Blind Handover Based on Event 1F........................................................................................................................... 121
13 Compressed Mode...................................................................................................................133
13.1 Overview.................................................................................................................................................................. 133
13.2 Compressed Mode Switches.....................................................................................................................................133
13.3 Compression Methods.............................................................................................................................................. 135
13.3.1 SF/2 Compressed Mode.........................................................................................................................................136
13.3.2 Higher Layer Scheduling Compressed Mode........................................................................................................138
13.4 Compression Types...................................................................................................................................................138
13.5 Measurement Timer Length......................................................................................................................................139
13.6 Check of Compressed Mode Parameter Settings During Inter-RNC Handover...................................................... 139
13.7 Compatibility Switch for Dual-frequency Receiver................................................................................................. 140
13.8 Compatibility Switches for HSPA............................................................................................................................ 140
14 Related Features.......................................................................................................................142
14.1 WRFD-01061006 HSDPA Mobility Management...................................................................................................142
14.2 WRFD-01061204 HSUPA Mobility Management...................................................................................................143
14.3 WRFD-020302 Inter Frequency Hard Handover Based on Coverage..................................................................... 144
14.4 WRFD-021200 HCS (Hierarchical Cell Structure)..................................................................................................145
14.5 WRFD-020304 Inter Frequency Hard Handover Based on DL QoS....................................................................... 145
14.6 WRFD-020309 Inter-RAT Handover Based on DL QoS......................................................................................... 146
17 Parameters................................................................................................................................. 209
18 Counters.................................................................................................................................... 802
19 Glossary..................................................................................................................................... 994
20 Reference Documents............................................................................................................. 995
1.1 Scope
This document describes handover, including its technical principles, network impact, and
engineering guidelines.
NE Type NE Model
Micro BTS3902E
l Feature change
Changes in features of a specific product version
l Editorial change
Changes in wording or addition of information that was not described in the earlier
version
RAN17.1 04 (2016-07-26)
This issue includes the following changes.
RAN17.1 03 (2015-09-10)
This issue includes the following changes.
RAN17.1 02 (2015-06-27)
Compared with Issue 01 (2015-03-25) of RAN17.1, Issue 02 (2015-06-27) of RAN17.1
includes the following changes.
RAN17.1 01 (2015-03-25)
This issue does not include any changes.
NOTE
Y indicates that a feature is supported; N indicates that a feature is not supported; NA indicates that an NE is
not involved, that is, a feature does not require the support of the NE.
The features described in this document are implemented in the same way on macro, micro,
and LampSite base stations.
The BTS3902E supports none of the new and enhanced features of RAN17.1. For details, see
1.3 Change History.
2 Overview of Handover
Handover is a basic function of the cellular mobile network. The purpose of handover is to
ensure that a UE in CELL_DCH state is served continuously when it moves.
Figure 2-1 shows the handovers supported by the Universal Mobile Telecommunications
System (UMTS), which include intra-frequency handover, inter-frequency handover, and
inter-RAT handover.
3 Intra-Frequency Handover
3.1 Overview
Intra-frequency handover is classified into:
l Intra-frequency soft handover: Multiple radio links are connected to the UE at the same
time during handover.
l Intra-frequency hard handover: Only one radio link is connected to the UE during
handover.
l Softer handovers: This type of handover occurs within a NodeB, and the NodeB
performs maximum ratio combination for the uplink signals.
Softer handovers can be performed only between cells in the same uplink resource
group. In versions earlier than RAN13.0, softer handovers cannot be performed between
cells that are configured in different downlink resource groups. In RAN13.0 and later
versions, softer handover can be performed between cells that are configured in different
downlink resource groups.
l Intra-RNC inter-NodeB soft handover: This type of handover is implemented by the
WRFD-020202 Intra RNC Soft Handover feature. During this type of handover, the
RNC performs selective combination for uplink signals.
l Inter-RNC soft handover: This type of handover is implemented by the WRFD-020203
Inter RNC Soft Handover feature. During this type of handover, the RNC performs
selective combination for uplink signals.
During this type of handover, the RNC performs selective combination for uplink signals.
Intra-frequency soft handover is characterized by the function that the UE can be connected to
multiple Universal Terrestrial Radio Access Network (UTRAN) access points at the same
time. Addition and release of radio links are controlled by the ACTIVE SET UPDATE
procedure.
During an inter-RNC soft handover, among all RLs of the UE, one or multiple RLs are
connected to the same or different NodeBs under the source RNC while the other RLs are
connected to the same or different NodeBs under the target RNC. If intra-frequency cells for
an inter-RNC soft handover are configured in different uplink resource groups,
CMP_IUR_SHO_DIVCTRL_SWITCH of the CmpSwitch(BSC6900,BSC6910) parameter
must be set to ON. Under this circumstance, the NodeB determines whether to combine the
RLs on the NodeB based on the value of DivCtrlField(BSC6900,BSC6910).
If no Iur interface exists between two RNCs, neither soft handover nor intra-frequency hard handover is
allowed between them.
Intra-frequency hard handover in this section refers to the intra-frequency hard handover without SRNS
relocation. If there is no Iur interface between two RNCs, combined hard handover and SRNS relocation
can be performed between the RNCs. For details, see SRNS Relocation and DSCR Feature Parameter
Description.
Whether the Iur interface is available depends on the setting of the following two parameters
according to handover types:
l Whether intra- or inter- frequency hard handover is allowed over the Iur interface
depends on the setting of the HHOTRIG(BSC6900,BSC6910) parameter.
l Whether inter RNC soft Handover is allowed depends on the setting of the
SHOTRIG(BSC6900,BSC6910) parameter.
If the RRC connection has been set up but the Radio Bearers (RBs) have not, whether a cross-
Iur soft handover can be executed is determined by the
HO_MC_SIGNAL_IUR_INTRA_SWITCH switch under the
HoSwitch(BSC6900,BSC6910) parameter. Only if the switch is set to ON, can the cross-Iur
soft handover be executed.
NOTE
After the UE transits to the CELL_DCH state in connected mode during a call, the RNC
sends a MEASUREMENT CONTROL message to instruct the UE to take measurements and
report the measurement event results.
Upon the reception of an event report from the UE, the RNC makes a handover decision and
performs the corresponding handover, as shown in Figure 3-1.
Event Description
1A A primary CPICH enters the reporting range. This indicates that the
CPICH signal quality of a cell in the monitored set is close to the
CPICH signal quality of the best cell in the active set. A relatively
high combined gain can be achieved when the cell is added to the
active set.
1B A primary CPICH leaves the reporting range. This indicates that the
CPICH signal quality of a cell in the active set is lower than the
CPICH signal quality of the best cell in the active set and the
difference between them is higher than a specified threshold. The
cell has to be deleted from the active set.
1D The best cell changes. This indicates that the CPICH signal quality
of a non-best cell is higher than the CPICH signal quality of the best
cell in the active set and the difference between them exceeds a
specified threshold, and the non-best cell becomes the new best cell.
The non-best cell can be a cell in the active set or in the monitored
set.
l NA is the number of cells not forbidden to affect the reporting range in the active set. The
parameter CellsForbidden1A(BSC6900,BSC6910) indicates whether adding the cell to
the active set affects the relative threshold of event 1A.
l MBest is the measurement value of the best cell in the active set.
l R1a is the reporting range or the relative threshold of soft handover. The threshold
parameters of the CS non-VP services, CS VP services, and PS services are as follows:
IntraRelThdFor1ACSNVP(BSC6900,BSC6910)
IntraRelThdFor1ACSVP(BSC6900,BSC6910)
IntraRelThdFor1APS(BSC6900,BSC6910)
NOTE
For the PS and CS combined services, the thresholds for CS services are used.
For the single signaling connection of the UE, the thresholds for CS services are used.
l H1a represents HystFor1A(BSC6900,BSC6910) the hysteresis value of event 1A
Figure 3-2 shows the triggering of event 1A. In this procedure, the default parameter values
(W=0, H1a =0) are used.
For the PS and CS combined services, the thresholds for CS services are used.
If the UE currently has only signaling connections, the thresholds for CS services are used.
l H1b is the hysteresis value of event 1B, which is determined by the parameter
Hystfor1B(BSC6900,BSC6910).
Configuration rule and restriction
l The value of IntraRelThdFor1BCSNVP(BSC6900,BSC6910) has to be larger than that
of IntraRelThdFor1ACSNVP(BSC6900,BSC6910).
Figure 3-3 shows the triggering of event 1B. In this procedure, the default parameter values
(W=0, H1b =0) are used.
In Figure 3-3,
Th1B = (CPICH Ec/N0 of the best cell in the active set) - (reporting range for event 1B)
If the signal quality of a cell in the active set is lower than Th1B for a period of time specified
by TrigTime1B(BSC6900,BSC6910) (Time to trigger in Figure 3-3), the UE reports event
1B.
If W > 0 and H1b = 0, then Th1B = (general signal quality of all the cells in the active set) -
(reporting range for event 1B).
Figure 3-4 shows the triggering of event 1C. In this procedure, the default parameter values
are used.
l E: curve of Th1C
Th1C = (CPICH Ec/N0 of the worst cell in the active set) + (hysteresis/2)
where
l Hysteresis is equal to the value of Hystfor1C(BSC6900,BSC6910).
If the signal quality of a cell not in the active set is higher than Th1C for a period of time
specified by TrigTime1C(BSC6900,BSC6910) (Time to trigger in the figure), the UE reports
event 1C, as shown in the figure.
The UE reports event 1C for qualified cells after the number of cells in the active set reaches
the maximum value. The maximum number of cells in the active set can be set by the
MaxCellInActiveSet(BSC6900,BSC6910) parameter.
l MNotBest is the measurement value of a cell that is not the best cell.
l CIONotBest is equal to the sum of CIO(BSC6900,BSC6910) and
CIOOffset(BSC6900,BSC6910), which is the offset between the cell in the reporting
range and the best cell in the active set.
l MBest is the measurement value of the best cell in the active set.
l CIOBest is the cell individual offset value of the best cell.
When the HO_CIO_1D_USED option in the HoSwitch(BSC6900,BSC6910)
parameter for the SET UCORRMALGOSwitch command is selected, the value of
CIOBest equals the value of the CIO(BSC6900,BSC6910)parameter, which is set by
running the ADD UCELLSETUP command.
l When the HO_CIO_1D_USED option in the HoSwitch(BSC6900,BSC6910) parameter
for the SET UCORRMALGOSwitch command is not selected, the value of CIOBest is
0.
l H1d is the hysteresis value of event 1D, which is determined by the parameter
Hystfor1D(BSC6900,BSC6910).
Figure 3-5 shows the triggering of event 1D. In this procedure, the default parameter values
are used.
If the signal quality of a cell not in the active set is higher than Th1D for a period of time
specified by TrigTime1D(BSC6900,BSC6910) (Time to trigger in the figure), the UE reports
event 1D.
When receiving an event 1A, 1C, or 1D report, the RNC adds a target cell to the active set
only when the CPICH Ec/N0 of the target cell is higher than the absolute threshold
SHOQualmin(BSC6900,BSC6910).
NOTE
To enable the UEs in the cells in the monitored set to report event 1D, you need to turn on the intra-
frequency hard handover switch, that is, select the HO_INTRA_FREQ_HARD_HO_SWITCH switch
of the HoSwitch(BSC6900,BSC6910) parameter in the SET UCORRMALGOSWITCH command.
Table 3-3 lists different types of intra-frequency handover decision and execution based on
different events.
1A When receiving an event 1A report, the RNC decides whether to add or replace
a cell in the active set.
For event 1A, the UE can report more than one cell in the event list in one
measurement report. These cells are in the list of the MEASUREMENT
CONTROL message, and they are sequenced in descending order of
measurement quantity.
For the cells in the list, the RNC adds the radio link to the active set only if the
number of cells in the active set does not reach the maximum value. If the
number of cells in the active set has reached the maximum value, the RNC
determines whether to initiate replacement of cells in the active set according to
the switch for the function of substituting intra-frequency measurement
triggered by event 1A for that triggered by event 1C is enabled. For
descriptions of this function, see section Intra-Frequency Handover Decision
and Execution Triggered by Event 1A that Serves as a Substitute for Event
1C.
1B When receiving an event 1B report, the RNC decides whether to delete a cell.
For event 1B, if there is more than one radio link in the active set, the RNC
decides whether to delete a radio link. This operation is not required if there is
only one radio link in the active set.
1C After receiving an event 1C report, the RNC decides whether to change the
worst cell.
For event 1C, the UE reports a list that contains good cells and the cells to be
replaced, and sequences the cells in descending order by measurement quantity.
After receiving the list from the UE, the RNC replaces the bad cells in the
active set with the good cells in the list.
According to the status of this switch, the RNC determines whether to initiate replacement of
cells in the active set:
l If the number of cells in the active set has reached the maximum value and this function
is disabled, the RNC does not initiate replacement of cells in the active set.
l If the number of cells in the active set has reached the maximum value and the function
of substituting intra-frequency measurement triggered by event 1A for that triggered by
event 1C is enabled, the RNC decides whether to initiate replacement of cells in the
active set according to the following formula: MNew > MInAS + H1c/2. If the condition
indicated by the formula is met, the RNC initiates replacement of cells in the active set
and the replacement process is the same as that for replacing cells in the active set after
event 1C is triggered. In the preceding formula:
MNew> MInAS + H1c/2
MNew is the measured value of the best cell in an event 1A report.
MInAS is the measured value of the worst cell in an event 1A report.
H1c is the hysteresis (decibel/dB) for event 1C, which is determined by the
Hystfor1C(BSC6900,BSC6910) parameter.
l The number of event 1C reports occupies more than 25% of the total number of event
1A, 1B, and 1C reports, as indicated by the following formula: VS.RRC.MrRpt.
1C(BSC6900,BSC6910)/(VS.RRC.MrRpt.1A(BSC6900,BSC6910) +
VS.RRC.MrRpt.1B(BSC6900,BSC6910) + VS.RRC.MrRpt.
1C(BSC6900,BSC6910)) > 25%.
This function is successfully enabled if the number of event 1A reports increase whereas the
number of event 1C reports decrease to 0.
If this function is enabled when the preceding condition is met, the soft handover success rate
has an increase of 0% to 5% and even has a greater increase in TopN cells where the
preceding problems are worse.
3.5.1 Overview
If a soft handover fails, the RNC follows up by performing the following procedures:
1. Rate reduction
For a UE processing R99 non-real-time services (abbreviated as NRT services) in uplink
and downlink, if the RNC fails to set up a radio link for the UE during the admission
phase of a soft handover, the RNC reduces the service rate of the UE and then sets up a
radio link again, increasing the soft handover success rate. For details, see section 3.5.2
Rate Reduction After an SHO Failure.
2. State transition from Cell_DCH to Cell_FACH (D2F for short)
If the RNC fails to set up a radio link for a UE during a soft handover, the RNC triggers
a D2F transition for the UE in the best cell when the target cell's signal quality is greater
than the best cell's signal quality plus a preset threshold value. This is to reduce the
interference to the target cell caused by UEs processing R99 NRT services in the uplink.
For details, see section 3.5.3 D2F Transition After a Soft Handover Failure.
3. Channel reconfiguration from E-DCH to DCH (E2D for short)
If the RNC fails to set up a radio link for an HSUPA UE during a soft handover or the
target cell does not support E2D reconfiguration for HSUPA UEs, the RNC triggers the
E2D reconfiguration procedure for the HSUPA UE. This is to reduce the interference to
the target cell caused by UEs processing HSUPA NRT services in the uplink. For details,
see section 3.5.4 E2D Reconfiguration After a Soft Handover Failure.
For a UE processing R99 NRT services in uplink and downlink, the following principles
apply after a soft handover failure:
l If the UE service rate can be reduced, the RNC reduces the UE service rate as described
in section 3.5.2 Rate Reduction After an SHO Failure
l If the UE service rate cannot be reduced because the rate reduction algorithm has not
taken effect or the UE has been using the guaranteed bit rate (GBR), the RNC triggers a
D2F transition when the conditions are met, as described in section 3.5.3 D2F
Transition After a Soft Handover Failure
NOTE
The follow-up procedures for soft handover failures reduce the possibility of received total wideband
power (RTWP) or channel element (CE) congestion in a cell but increase the number of RB
reconfigurations and the call drop rate.
1. The RNC evaluates whether the measurement quantity of the cell failing to be admitted
meets the condition of rate reduction.
If the condition is met, the RNC performs a rate reduction process for the access
service immediately, For details, see Procedure of Rate Reduction Execution.
If the condition is not met, the RNC performs the next step (Step 2).
The condition of rate reduction is as follows: Mnew > Mbest_cell -
RelThdForDwnGrd(BSC6900,BSC6910)
Mnew is the CPICH Ec/N0 measurement value of the cell failing to be admitted.
Mbest_cell is the CPICH Ec/N0 measurement value of the best cell in the active set.
RelThdForDwnGrd(BSC6900,BSC6910) is a parameter.
2. The RNC evaluates whether the number of SHO failures in the cell exceeds the
ShoFailNumForDwnGrd(BSC6900,BSC6910).
If the number of SHO failures in the cell is smaller than the
ShoFailNumForDwnGrd(BSC6900,BSC6910):
If the timer has not been started, the RNC starts it.
If the timer has been started, the RNC increments the SHO failure counter by one.
The timer length is set through the parameter ShoFailPeriod(BSC6900,BSC6910).
The SHO failure counter of a cell is used to record the number of SHO failures in
this cell. For each UE, the RNC records the number of SHO failures occurred in
first three cells at most. For SHO failures in any other cells, the RNC does not
record the number.
Before the SHO failure evaluation timer expires, no action is taken and the RNC
waits for the next measurement report period.
When the SHO failure evaluation timer expires, the RNC sets the SHO failure
counter of the corresponding cell to 0 and ends the evaluation.
If the number of SHO failures in the cell is larger than or equal to the parameter
ShoFailNumForDwnGrd(BSC6900,BSC6910), the RNC performs a rate reduction
process for the access service,
1. The RNC performs a rate reduction process for the access service.
To determine the access rate after the rate reduction, see the "Rate Negotiation at
Admission Control" section in Load Control Feature Parameter Description.
If the rate reduction fails, the RNC sets the SHO failure counter of the cell to 0 and ends
the rate reduction process.
2. If the rate reduction succeeds, the RNC makes an admission decision for the UE.
If admitting the UE to the cell succeeds, the RNC adds this cell to the active set
without measurement and adds the radio link for the UE.
If admitting the UE to the cell fails, the RNC starts the penalty timer
(DcccShoPenaltyTime(BSC6900,BSC6910)) to avoid a rate increase triggered by
DCCC within the period. When the penalty timer expires, the RNC sets the SHO
failure counter of the cell to 0 and ends the rate reduction process.
If the RNC fails to perform a soft handover again, it performs the estimation and execution
procedures, as previously described.
Target cell's Ec/N0 > Best cell's Ec/N0 + D2F quality offset for soft handover failures
When the preceding inequation applies, the interference to the target cell caused by the UE is
greater than that to the best cell.
When the D2F transition of the UE succeeds, the RNC starts a penalty timer for state
transitions from Cell_FACH to Cell_DCH (F2D for short).
l F2D transitions for the UE are forbidden until the penalty timer expires or the UE
initiates a CS service.
l The penalty timer stops if a cell update occurs due to the cell change.
To turn on the D2F transition switch for soft handover failures, set the
SoftFailD2FSwitch(BSC6900,BSC6910) parameter to ON. The D2F quality offset is
determined by setting the SoftFailD2FOffset(BSC6900,BSC6910) parameter. The value of
the F2D penalty timer is determined by setting the
SoftFailF2DPunishTimer(BSC6900,BSC6910) parameter.
The preceding parameters can be set by running the SET UINTRAFREQHO command.
To turn on the E2D reconfiguration switch for soft handover failures, set the
SoftFailE2DSwitch(BSC6900,BSC6910) parameter in the SET UINTRAFREQHO
command to ON. If the independent active set function is enabled, a DC-HSUPA UE will fall
back to the DCH when it fails to access any link on the primary carrier. If the admission of a
link on the secondary carrier fails, the UE remains on the DC-HSUPA carriers.
When an E2D reconfiguration procedure for a UE succeeds, the RNC starts a penalty timer
for the UE. During the penalty period, periodic DRDs for the UE, including blind-handover-
based periodic DRDs and measurement-based periodic DRDs, are forbidden; D2E
reconfiguration triggered by dynamic channel configuration control (DCCC) is forbidden;
D2E state transition is forbidden if the target cell does not support HSUPA.
The value of the penalty timer is fixed to 20s. For details about periodic DRDs, see Directed
Retry Decision Feature Parameter Description.
NOTE
The RNC does not trigger E2D reconfiguration for the UE if the soft handover fails due to a downlink
admission failure. This is because the uplink resources of the target cell are not congested if only a
downlink admission failure occurs.
The connections involved in the intra-NodeB intra-frequency softer handover change are as
follows:
l Before the softer handover, only cell 1 is connected to the UE.
l During the softer handover, both cell 1 and cell 2 are connected to the UE.
l After the softer handover, only cell 2 is connected to the UE. Cell 1 is removed from the
active set.
Figure 3-11 Signaling procedure for intra-RNC inter-NodeB intra-frequency soft handover
Figure 3-15 Signaling procedure for intra-RNC inter-NodeB intra-frequency hard handover
As shown in Figure 3-15, NodeB 1 is the source NodeB and NodeB 2 is the target NodeB.
As shown in Figure 3-17, NodeB 1 is the source NodeB and NodeB 2 is the target NodeB.
l When this switch is turned on, the UE reports the information about both monitored set
cells and detected set cells.
l When this switch is turned off, the UE reports the information about monitored set cells
only.
Monitored set cells reported by the UE are directly added to the active set according to the
mechanism of adding cells to the active set in the soft handover procedure.
Detected set cells can be added to the active set only when they meet specific conditions. For
details, see Procedure Optimization Feature Parameter Description.
If either of the preceding conditions is not met, the RNC does not send a measurement control
message to the UE.
4.1 Overview
Based on the handover triggering causes, the inter-frequency and inter-RAT handover falls
into five categories, as described in Table 4-1. Inter-RAT handover in Table 4-1 refers to the
handover between 3G and 2G networks.
This section mainly describes the 3G-to-2G coverage-based handover and QoS-based
handover. Except the cause of the triggering is different, the handover procedure is the same
for the coverage-based handover and QoS-based handover.
Inter-frequency handovers described in this document are divided into two types: intra-band
inter-frequency handovers and inter-band inter-frequency handovers. The two types of
handovers use the same procedure. However, their prerequisite features are different, as
described in 14.3 WRFD-020302 Inter Frequency Hard Handover Based on Coverage.
NOTE
Unless otherwise specified, inter-RAT handover refers to the handover performed between 3G and 2G
networks.
For details about the handover between UMTS and LTE networks, see Interoperability Between UMTS
and LTE Feature Parameter Description.
Type Description
Type Description
NOTE
If the switch is turned on, the RNC sends the inter-frequency measurement control
message with the neighboring cell, whose frequency is not included in the
measurement capability of the UE.
If the switch is turned off, the RNC sends the inter-frequency measurement control
message without the neighboring cell, whose frequency is not included in the
measurement capability of the UE.
The switch is turned off by default.
l Certain UEs may fail in inter-frequency handovers and UMTS-to-GSM inter-RAT
handovers due to compatibility issues. The following action is required for these UEs to
avoid compatibility issues:
After the UE IMEIs are identified, add the UEs to the blacklist. For details about the
blacklist setting, see Terminal Black List Feature Parameter Description. To configure
the blacklist for inter-frequency or inter-RAT handovers, set the
TAC_FUNC(BSC6900,BSC6910) parameter to Special_User_Enhance and select
RESERVED_SWITCH_BIT30 or RESERVED_SWITCH_BIT31 under the
RsvSwitch(BSC6900,BSC6910) parameter.
To add an inter-frequency blacklist, run the following commands:
ADD UIMEITAC: TAC_FUNC=Special_User_Enhance, TAC=XXXXXX,
Description="inter-frequency blacklist",
RsvSwitch=RESERVED_SWITCH_BIT30-1;
To add an inter-RAT blacklist, run the following commands:
ADD UIMEITAC: TAC_FUNC=Special_User_Enhance, TAC=XXXXXX,
Description="inter-RAT blacklist", RsvSwitch=RESERVED_SWITCH_BIT31-1;
After the UE blacklist function is enabled, the principles for inter-frequency handovers
and inter-RAT handovers are as follows:
Coverage-based handovers
If a UE has been added to both the inter-frequency blacklist and the inter-RAT
blacklist, the RNC does not send 2D or 2F measurement control. If the UE has been
added to either the inter-frequency blacklist or the inter-RAT blacklist, the RNC
sends 2D and 2F measurement control. However, after the UE reports 2D
measurement result, the RNC does not send the inter-frequency measurement
control (if the UE is added to the inter-frequency blacklist) or inter-RAT
measurement control (if the UE is added to the inter-RAT blacklist).
QoS-based handovers
The RNC does not send inter-frequency measurement control to UEs that are
already added to the inter-frequency blacklist even if QoS requirements are met.
Load-based handovers
Within an LDR period, the RNC selects UEs based on UE priorities. If the selected
UEs are blacklisted, and the blacklist type (inter-frequency and inter-RAT) is
inconsistent with LDR operations, the RNC does not trigger handovers. In this
scenario, LDR operations do not take effect within the LDR period.
Service-based handovers
The RNC does not trigger handovers for UEs that are added to the inter-frequency
blacklist or inter-RAT blacklist even if handover conditions are met.
HCS-based handovers
The RNC does not trigger handovers for UEs that are added to the inter-frequency
blacklist or inter-RAT blacklist even if handover conditions are met.
Blind handovers
No blind handover is triggered for UEs that are added to the inter-frequency
blacklist if event 1F is reported. The blind handovers include 1F-based emergent
blind handovers, forcible blind handovers, and coverage-based blind handovers.
The RNC does not trigger handovers for UEs that are performing emergency calls
and are added to the inter-frequency blacklist or inter-RAT blacklist even if
handover conditions are met.
NOTE
Figure 4-2 Signaling procedure for inter-frequency handover between NodeBs within one
RNC
As shown in Figure 4-2, NodeB 1 is the source NodeB, whereas NodeB 2 is the target
NodeB. From step 1 through step 6, a new connection is set up. From step 7 through step 9,
the original connection is released.
Figure 4-4 Signaling procedure for inter-frequency hard handover between the RNCs
NodeB 1 is the source NodeB, whereas NodeB 2 is the target NodeB. From step 1 through
step 10, a new connection is set up. From step 11 through step 13, the original connection is
released.
The 3G-to-2G handover in the PS domain is triggered through the cell reselection.
The following figure shows an example of handover for the UE in CELL_FACH,
CELL_PCH, or URA_PCH state. When the UE is in idle mode, the cell reselection procedure
does not include the elementary procedures marked "UE CONNECTED" in Figure 4-6.
NOTE
If a UE, either in idle mode or in connected mode, performs a 3G-to-2G handover and the same SGSN
serves the UE before and after the handover, all messages sent to or from the two SGSNs in the
preceding figure will be converged in the same SGSN. In this case, signaling interaction procedures in
steps 3, 5, 7, and 9 are not required.
The GSM system uses time division multiple access technology, and the inter-RAT
measurement is performed in idle timeslots. Therefore, the GSM does not need to support the
compressed mode.
If a moving UE leaves the coverage area of the current frequency or the link quality in the
uplink or downlink degrades, the RNC triggers a coverage-based or QoS-based inter-
frequency or inter-RAT handover to avoid call drops. The QoS-based handover procedure is
the same as the coverage-based handover procedure in the uplink or downlink.
handover is required, the RNC initiates a QoS-based handover. For details about the
triggering conditions of QoS-based handovers for CS services, see the "Link
Stability Control for AMR" section in AMR Feature Parameter Description. For
details about the triggering conditions of QoS-based handovers for BE services, see
the "Link Stability Control for BE" section in DCCC Feature Parameter
Description.
l In the measurement phase
The RNC sends a measurement control message to the UE. Upon receipt of this message,
the UE performs inter-frequency or inter-RAT handover measurement.
In this phase, the method of either periodical measurement report or event-triggered
measurement report can be used.
l In the decision phase
The RNC makes a handover decision based on event 2B, event 3A, or periodical
measurement report sent by the UE.
l In the execution phase
The RNC performs the handover procedure.
5.2.1 Overview
If the UE can perform measurement only in compressed mode during the measurement phase,
the RNC needs to start the compressed mode before sending a measurement control message
to the UE. Otherwise, the RNC can directly send a measurement control message to the UE.
Upon receipt of the measurement control message, the UE performs inter-frequency or inter-
RAT handover measurement. For details about the compressed mode, see chapter 13
Compressed Mode.
Two RNC-level timers, CsHoPrioMeasTimerLen(BSC6900,BSC6910) and
PsHoPrioMeasTimerLen(BSC6900,BSC6910), are available in the SET UHOCOMM
command.
These timers specify the time interval from the time when an inter-frequency measurement
control message for CS or PS services is sent to the time when an inter-RAT measurement
control message for CS or PS services is sent. When a UE processing a CS or PS service is
about to perform an inter-frequency or inter-RAT handover, the RNC preferentially sends the
UE an inter-frequency measurement control message after compressed mode is started. If no
inter-frequency neighboring cell meets the required conditions or the inter-frequency
handover fails, the RNC sends the UE an inter-RAT measurement control message after the
corresponding timer expires.
l If CsHoPrioMeasTimerLen(BSC6900,BSC6910) or
PsHoPrioMeasTimerLen(BSC6900,BSC6910) is set to 0, the RNC sends the UE an
inter-frequency measurement control message and an inter-RAT measurement control
message at the same time.
l If CsHoPrioMeasTimerLen(BSC6900,BSC6910) or
PsHoPrioMeasTimerLen(BSC6900,BSC6910) is set to a non-zero value, the RNC
preferentially sends the UE an inter-frequency measurement control message. The RNC
sends the UE an inter-RAT measurement control message only after the corresponding
timer expires.
The unused frequencies belong to a GSM cell, and the unused frequency measurement
quantity is referred to as to GSM RSSI.
1. From the neighboring cell list of the best cell, the RNC selects at most two frequencies to
be measured based on the Priority of Coverage-Based Inter-Frequency Handover for
neighboring cells.
2. The RNC selects neighboring cells to be measured according to the following rules:
When the neighboring cell combination function is enabled, the RNC selects
neighboring cells according to the rules described in chapter 11 Neighboring Cell
Combination.
When the neighboring cell combination function is disabled, the RNC selects a
maximum of 32 neighboring cells from the neighboring cell list of the best cell
based on the value of the Priority of Coverage-Based Inter-Frequency Handover for
neighboring cells.
For details about event triggering conditions, see section 14.2.1 Inter-frequency reporting
events and 14.3.1 Inter-RAT reporting event in 3GPP TS 25.331 V10.0.0.
Triggering of Event 2D
After the trigger conditions of event 2D are fulfilled and maintained until the value of the
Event 2D Trigger Delay parameter is reached, the UE sends the event 2D measurement
report message.
Event 2D is triggered on the basis of the following formula:
QUsed <= TUsed2d - H2d/2
where
l QUsed is the measured quality of the used frequency.
l TUsed2d is the absolute quality threshold of the cell that uses the current frequency. It is
specified by the event 2D threshold. The event 2D threshold varies depending on the
service type and measurement quantity, as described in Table 5-2.
l H2d is the event 2D hysteresis value. It is used to prevent ping-pong triggering of events
2D and 2F.
The principles for using event 2D-related parameters (event 2D trigger delay, hysteresis for
event 2D, and threshold for triggering event 2D) in different scenarios are as follows:
l When the neighboring cells are inter-frequency neighboring UMTS cells, event 2D-
related parameters configured for inter-frequency handover are used.
l When the neighboring cells are neighboring GSM cells, event 2D-related parameters
configured for inter-RAT handover are used.
l When the neighboring cells are neighboring LTE cells, event 2D-related parameters
configured for inter-RAT handover are used.
l When the neighboring cells are neighboring LTE and GSM cells, event 2D-related
parameters configured for inter-RAT handover are used.
l When the neighboring cells are neighboring LTE cells and inter-frequency neighboring
UMTS cells, event 2D-related parameters configured for inter-frequency handover are
used.
l When the neighboring cells are neighboring LTE cells, neighboring GSM cells, and
inter-frequency neighboring UMTS cells, or when the neighboring cells are neighboring
GSM cells and inter-frequency neighboring UMTS cells, the event 2D-related
parameters to be used depend on the setting of the
CoexistMeasThdChoice(BSC6900,BSC6910) parameter.
If this parameter is set to COEXIST_MEAS_THD_CHOICE_INTERFREQ,
event 2D-related parameters configured for inter-frequency handover are used.
If this parameter is set to COEXIST_MEAS_THD_CHOICE_INTERRAT, event
2D-related parameters configured for inter-RAT handover are used.
NOTE
l InterFreqR
99PsThd2D
RSCP(BSC
6900,BSC69
10) for R99
PS services
l InterFreqH
Thd2DRSC
P(BSC6900,
BSC6910)
for HSPA
services.
00,BSC6910
) for R99 PS
services
l InterRATH
Thd2DRSC
P(BSC6900,
BSC6910)
for HSPA
services
NOTE
Triggering of Event 2F
After the trigger conditions of event 2F are fulfilled and maintained until the value of the
Event 2F Trigger Delay parameter is reached, the UE sends the event 2F measurement report
message.
Event 2F is triggered on the basis of the following formula:
QUsed >= TUsed2f + H2f/2
where
l QUsed is the measured quality of the used frequency.
l TUsed2f is the absolute quality threshold of the cell that uses the current frequency. It is
specified by the event 2F threshold. The event 2F threshold varies depending on the
service type and measurement quantity, as described in Table 5-3.
l H2f is the event 2F hysteresis value. It is used to prevent ping-pong triggering of events
2D and 2F.
The principles for using event 2F-related parameters in different networking scenarios are the
same as those for using event 2D-related parameters. For event 2F-related parameters, see
Table 5-3.
l InterFreqR
99PsThd2F
RSCP(BSC
6900,BSC69
10) for R99
PS services
l InterFreqH
Thd2FRSC
P(BSC6900,
BSC6910)
for HSPA
services
00,BSC6910
) for R99 PS
services
l InterRATH
Thd2FRSC
P(BSC6900,
BSC6910)
for HSPA
services
NOTE
Triggering of Event 2B
After the trigger conditions of event 2B are fulfilled and maintained until the value of the
TimeToTrig2B(BSC6900,BSC6910) parameter is reached, the UE sends the event 2B
measurement report message.
Event 2B is triggered on the basis of the following formula:
QNoused >= TNoused2b + H2b/2
where
l QNoused is the measured quality of the cell that uses the other frequencies.
l QUsed is the measured quality of the used frequency.
l H2b is the event 2B hysteresis value set through the parameter
HystFor2B(BSC6900,BSC6910).
l TNoused2b is the quality threshold of the cells that use the target frequencies. Based on the
service type and measurement quantity, this threshold can be configured through the
following parameters:
TargetFreqCsThdEcN0(BSC6900,BSC6910)
TargetFreqCsThdRscp(BSC6900,BSC6910)
TargetFreqR99PsThdEcN0(BSC6900,BSC6910)
TargetFreqR99PsThdRscp(BSC6900,BSC6910)
TargetFreqHThdEcN0(BSC6900,BSC6910)
TargetFreqHThdRscp(BSC6900,BSC6910)
l TUsed2b is the absolute quality threshold of the cell that uses the current frequency.
Based on the service type and measurement quantity, this threshold can be configured through
the following parameters:
If event 2D with the CPICH RSCP value is received by the RNC:
l TUsed2b of event 2B with the CPICH RSCP value can be:
UsedFreqCSThdRSCP(BSC6900,BSC6910)
UsedFreqR99PsThdRSCP(BSC6900,BSC6910)
UsedFreqHThdRSCP(BSC6900,BSC6910)
l TUsed2b of event 2B with the CPICH Ec/N0 value is configured as the maximum value 0
dB.
According to section 10.37.39 Intra-frequency measurement reporting criteria in 3GPP
TS 25.331 V10.0.0, TUsed2b of event 2B with the CPICH Ec/N0 value should be
configured as the maximum value 0 dB. If the event 2F with the CPICH Ec/N0 value is
received by the RNC and TUsed2b of event 2B with the CPICH Ec/N0 value is modified,
TUsed2b is reset to 0 dB.
Triggering of Event 3A
After the trigger conditions of event 3A are fulfilled and maintained until the value of the
TrigTime3A(BSC6900,BSC6910) parameter is reached, the UE sends the measurement report
of event 3A.
Event 3A is triggered on the basis of the following formula:
where
l QUsed is the measurement value of the cell at the currently used frequency.
l TUsed is the absolute quality threshold of the cell that uses the current frequency. Based
on the service type and measurement quantity in the coverage-based handover, TUsed can
be configured through the following parameters:
UsedFreqCSThdEcN0(BSC6900,BSC6910)
UsedFreqCSThdRSCP(BSC6900,BSC6910)
UsedFreqHThdEcN0(BSC6900,BSC6910)
UsedFreqHThdRSCP(BSC6900,BSC6910)
UsedFreqR99PsThdEcN0(BSC6900,BSC6910)
UsedFreqR99PsThdRSCP(BSC6900,BSC6910)
In the coverage-based handover, based on the measurement quantity (CPICH Ec/N0
or RSCP), TUsed is configured as follows:
If the measurement quantity is CPICH Ec/N0:
If event 2D is triggered by RSCP, TUsed is configured as the maximum value 0 dB.
If event 2D is triggered by Ec/N0, TUsed is configured as the Ec/N0 threshold
specified by the previous parameters.
If the measurement quantity is CPICH RSCP:
If event 2D is triggered by RSCP, TUsed is configured as the RSCP threshold
specified by the previous parameters.
If event 2D is triggered by Ec/N0, TUsed is configured as the maximum value -25
dBm.
In the uplink QoS-based handover, based on the measurement quantity (CPICH
Ec/N0 or RSCP), TUsed is configured as the maximum value according to section
10.37.39 Intra-frequency measurement reporting criteria in 3GPP TS 25.331
V10.0.0, as described below:
If the measurement quantity is CPICH Ec/N0, TUsed is configured as the maximum
value 0 dB.
If the measurement quantity is CPICH RSCP, TUsed is configured as the maximum
value -25 dBm.
In the downlink QoS-based handover:
If the measurement quantity is CPICH Ec/N0, TUsed is configured as the maximum
value 0 dB.
If the measurement quantity is CPICH RSCP, based on the service type, TUsed can
be configured as one of the following sums:
UsedFreqCSThdRSCP(BSC6900,BSC6910) and
DlRscpQosHyst(BSC6900,BSC6910)
UsedFreqR99PsThdRSCP(BSC6900,BSC6910) and
DlRscpQosHyst(BSC6900,BSC6910)
UsedFreqHThdRSCP(BSC6900,BSC6910) and
DlRscpQosHyst(BSC6900,BSC6910)
l MOtherRAT is the measurement value of the cell (in another RAT) in the reporting range.
l CIOOtherRAT is the cell individual offset value of the cell (in another RAT) in the
reporting range, which is equal to the sum of CIO(BSC6900,BSC6910) and
CIOOffset(BSC6900,BSC6910).
l TOtherRAT is the absolute inter-RAT handover threshold. Based on different service types
(CS services, PS R99 services, or PS HSPA services), this threshold can be configured
through the following parameters:
TargetRatCsThd(BSC6900,BSC6910)
TargetRatR99PsThd(BSC6900,BSC6910)
TargetRatHThd(BSC6900,BSC6910)
l H3a is 3A hysteresis, the hysteresis value of event 3A.
l For the PS and CS combined services, when the switch HoSwitch(BSC6900,BSC6910):
HO_MULTIRAB_CSPS_HO_COV_PARA_SWITCH is set to ON, TUsed is specified
by UsedFreqCSPSThdRSCP(BSC6900,BSC6910) or
UsedFreqCSPSThdEcN0(BSC6900,BSC6910), and TOtherRAT is specified by
TargetRatCSPSMRABThd(BSC6900,BSC6910). Otherwise, the thresholds for CS
services are used.
enhances the reliability of handover. The BSICVerify parameter is the control switch for the
BSIC verification.
After compressed mode is started, if the RNC instructs a UE to measure only neighboring
GSM cells during an inter-RAT handover, the UE needs to measure the RSSI, Init BSIC
(initial BSIC verification), and BSIC Reconfirm (BSIC re-verification). The Init BSIC and
BSIC Reconfirm are collectively termed BSIC verification.
During an inter-RAT handover, the RNC-level parameters
CSBSICVerifyindication(BSC6900,BSC6910) and
PSBSICVerifyindication(BSC6900,BSC6910) in the SET UINTERRATHOCOV command
take effect only when BSICVerify(UMTS BSC6900,UMTS BSC6910) is set to REQUIRED.
CSBSICVerifyindication(BSC6900,BSC6910) specifies the BSIC verification mode for CS
services.
l If CSBSICVerifyindication(BSC6900,BSC6910) is set to
BSICINIT_AND_RECONFIRM, both initial BSIC verification and BSIC re-
verification are required.
l If CSBSICVerifyindication(BSC6900,BSC6910) is set to BSICINIT, only initial BSIC
verification is required.
PSBSICVerifyindication(BSC6900,BSC6910) specifies the BSIC verification mode for PS
services.
l If PSBSICVerifyindication(BSC6900,BSC6910) is set to
BSICINIT_AND_RECONFIRM, both initial BSIC verification and BSIC re-
verification are required.
l If PSBSICVerifyindication(BSC6900,BSC6910) is set to BSICINIT, only initial BSIC
verification is required.
l If PSBSICVerifyindication(BSC6900,BSC6910) is set to BSICINIT_ADPT, initial
BSIC verification is dynamically performed depending on whether the BCCHs of any
two inter-RAT neighboring cells use the same ARFCN.
BSIC re-verification is not performed. The cell-level parameters
CSBSICVerifyindication(BSC6900,BSC6910) and
PSBSICVerifyindication(BSC6900,BSC6910) are available in the ADD
UCELLINTERRATHOCOV and MOD UCELLINTERRATHONCOV commands. The
meanings of the cell-level parameters are the same as those of the RNC-level parameters.
When both the cell- and RNC-level parameters are set, the cell-level parameters prevail.
and start the measurement on new frequencies. If no more frequencies are to be measured, the
RNC stops compressed mode. A maximum of three batches of inter-frequency measurements
are supported, that is, a maximum of six frequencies are measured. If an inter-frequency or
inter-RAT handover is to be triggered, the UE can also measure the frequencies of inter-
frequency neighboring cells in batches.
1. Decides whether both the CPICH Ec/N0 value and CPICH RSCP value of the target cell
pilot signal meet the requirement of inter-frequency handover.
The evaluation formula is listed below: Mother_Freq + CIOother_Freq Tother_Freq + H/2
where
Mother_Freq is the CPICH Ec/N0 or CPICH RSCP measurement value of the target
cell reported by the UE. Both of the two measurement values of the inter-frequency
cell must satisfy the formula.
CIOother_Freq is the cell individual offset value of the target cell. It is equal to the
sum of CIO(BSC6900,BSC6910) and CIOOffset(BSC6900,BSC6910).
Tother_Freq is the quality threshold of the cells that use the target frequencies during
inter-frequency handovers. For details, see Triggering of Event 2B.
H is the inter-frequency hard handover hysteresis value set through the parameter
HystForPrdInterFreq(BSC6900,BSC6910).
2. Allows UEs to perform inter-frequency hard handovers to a neighboring cell if the
RTWP and CPICH RSCP of the neighboring cell meet the following formula: RTWP -
CPICH RSCP < Target frequency uplink coverage limit threshold. When the uplink
RTWP switch (InterFreqHOConsiderRTWPSw(BSC6900,BSC6910)) is turned on, the
RNC makes the judgment. When the uplink RTWP switch is turned off, the RNC does
not make the judgment.
The target frequency uplink coverage limit threshold is specified by the
TargetFreqUlCoverLimitThd(BSC6900,BSC6910) parameter in the SET
UCELLINTERFREQHOCOV command.
3. The RNC starts the hard handover time-to-trigger timer. The value of the hard handover
time-to-trigger timer is specified by the
Figure 5-2 Selecting the cell with the highest CPICH RSCP
1. Adds all the pilot cells that trigger event 2B to a cell set and arranges the cells according
to the measurement quality of CPICH_Ec/N0 in descending order.
2. Deletes a neighboring cell from the cell set if the RTWP and CPICH RSCP of the
neighboring cell meet the following formula: RTWP-CPICH RSCP Target frequency
uplink coverage limit threshold, which indicates that the UE is in the area where the
uplink coverage is poor. When the uplink RTWP switch
(InterFreqHOConsiderRTWPSw(BSC6900,BSC6910)) is turned on, the RNC makes
the judgment. When the uplink RTWP switch is turned off, the RNC does not make the
judgment.
3. Selects a cell from the cell set in sequence and instructs the UE to perform a handover to
the cell.
Before performing an inter-RAT handover, the RNC checks the signal quality of the best
cell. If the signal quality of the best cell is poor, the RNC does not trigger an inter-RAT
handover. This increases the inter-RAT handover success rate. The method of
determining the signal quality of the best cell is as follows:
The RNC checks whether the switches for reporting the signal quality of intra-frequency
neighboring cells in periodical inter-RAT measurement for a single CS service and a
single PS service, respectively, are turned on:
For a single CS service, the switch can be turned on by selecting
HO_CS_IRATHHO_WITH_INTRA_FREQ_MR_SWITCH of the
HoSwitch1(BSC6900,BSC6910) parameter in the SET
UCORRMALGOSWITCH command.
For a single PS service, the switch can be turned on by selecting
HO_PS_IRATHHO_WITH_INTRA_FREQ_MR_SWITCH of the
HoSwitch1(BSC6900,BSC6910) parameter in the SET
UCORRMALGOSWITCH command.
For CS and PS combined services, the switch is the same as that for a single CS
service.
If at least one switch is turned on, the periodical inter-RAT measurement reports
sent by the UE to the RNC contain the signal quality information about the cells in
the active set. The RNC checks the signal quality of the best cell in the active set of
the measurement report. If an inter-RAT neighboring cell meets the conditions of
inter-RAT handover, the RNC further checks whether the Ec/N0 of the best cell in
the active set meets the following formula:
Ec/N0 Lower Thd for Inter-RAT Intra-Frequency Handover
(UsedIRATHOLowerThdEcNo(BSC6900,BSC6910)) Ec/N0 of the best cell
Ec/N0 Upper Thd for Inter-RAT Intra-Frequency Handover
(UsedIRATHOUpperThdEcNo(BSC6900,BSC6910))
If the preceding formula is met, the RNC decides to perform an inter-RAT
handover. Otherwise, the RNC decides not to perform an inter-RAT handover. Note
that the RNC needs to send an intra-frequency neighboring cell measurement
control message to the UE because the RNC decides whether to perform an inter-
RAT handover based on the signal quality of intra-frequency neighboring cells. The
size of the inter-RAT measurement report increases when it contains the intra-
frequency neighboring cell measurement result, increasing the call drop rate.
If neither switch is turned on, the RNC selects a target cell and triggers a 3G-to-2G
handover.
NOTE
In an area where 2G and 3G networks are deployed, if the inter-RAT handover success rate is
lower than expected or if the customer is unsatisfied with the situation where the 3G network
signal quality is good enough for UEs to camp on but UEs are nevertheless handed over to the 2G
network, then:
l Turn on the switch for a single CS service to increase the inter-RAT handover success rate of
CS services, that is, select HO_CS_IRATHHO_WITH_INTRA_FREQ_MR_SWITCH of
the HoSwitch1(BSC6900,BSC6910) parameter.
l Turn on the switch for a single PS service to increase the inter-RAT handover success rate of
PS services, that is, select HO_PS_IRATHHO_WITH_INTRA_FREQ_MR_SWITCH of
the HoSwitch1(BSC6900,BSC6910) parameter.
4. Select a target cell. For details, see Target Cell Selection.
Inter-frequency The RNC selects the inter-frequency neighboring UMTS cell with the
neighboring best signal quality.
UMTS cells
handed over to the GSM 1800 MHz network, set the priorities of neighboring GSM 1800
MHz cells to values within the range of 0 to 3 and the priorities of neighboring GSM 900
MHz cells to values within the range of 4 to 7.
1. Puts all the 2G cells that trigger event 3A into a cell set and arranges the cells according
to the measurement quality in descending order.
2. Selects a cell from the cell set in sequence and instructs the UE to perform a handover to
the cell.
Capability Requirement
Before deciding the 3G-to-2G handover, the RNC considers 2G cell capability, service
capability, and UE capability.
The following table describes the impacts of different types of capability on handover
decision. If the capability of all neighboring 2G cells does not meet the requirement, the inter-
RAT measurement will not be triggered.
l For a UE with a single signaling RAB, the RNC supports the handover to the GSM,
which is not recommended.
l For the UE accessing combined services (with CS services), the RNC sets the service
handover indicator of the UE to that of CS services, because CS services have the
highest QoS priority.
l For the UE accessing combined services (with only PS services), the RNC sets the
service handover indicator of the UE to that of PS services with the highest QoS priority
If the service handover indicators are not configured by the CN, each indicator can be set to
the service parameter index of a service on the RNC. Each service parameter index is the
index of one typical service RAB, which involves a set of service type, source description,
CN domain ID, and maximum rate (bit/s).
1. The SRNC receives a measurement report from the UE and determines to reselect a
GERAN cell for the UE.
2. The SRNC sends a RAN INFORMATION REQUEST message to the SGSN.
3. The SGSN forwards the message to the target BSS.
4. The target BSS sends a RAN INFORMATION message, which contains the SI/PSI of
the GERAN, to the SRNC through the SGSN. The RAN INFORMATION message can
Information can be exchanged between different BSSs or between the BSS and RAN can be
implemented by exchanging RIM messages through either the CN or Huawei proprietary
eCoordinator.
NOTE
RIM messages can be exchanged between the UTRAN and GERAN through the eCoordinator when the
following conditions are met: Huawei devices used in the UTRAN and GERAN are connected to the
same eCoordinator. The CN to which the UTRAN and GERAN connect does not support the RIM
procedure or the RIM procedure is not enabled for the UTRAN and GERAN. When the RIM procedure
is performed through the eCoordinator, the switches for the RIM procedure must be set to on for NEs
involved in the procedure, such as BSC, eCoordinator, and RNC. Otherwise, the RIM procedure cannot
be performed through the eCoordinator and these NEs cannot send RIM messages to or respond to RIM
messages from the CN.
With NACC, the RNC sends a cell change order carrying the SI/PSI of the GERAN to the UE
when a UMTS-to-GSM handover is triggered. To enable the NACC function, do as follows:
If the HoSwitch(BSC6900,BSC6910):
HO_INTER_RAT_PS_3G2G_RELOCATION_SWITCH is turned on, the PS handover
from the 3G network to the 2G network is performed in the relocation process. When the
switch is not on, the PS handover from the 3G network to the 2G network is performed in the
cell change order process.
l For a UE that is processing CS services, the RNC enables the UE to continue processing
the CS services in the source cell only if the
AMR_HHO_FAIL_ROLLBACK_SWITCH check box under the
PROCESSSWITCH4(BSC6900,BSC6910) parameter in the SET URRCTRLSWITCH
command is selected.
l For a UE that is processing PS services, the RNC unconditionally enables the UE to
continue processing the PS services in the source cell.
If the number of handover failures caused by physical channel failures reaches the
value of the InterRatPhyChFailNum(BSC6900,BSC6910) parameter, the RNC
starts another penalty timer. During the penalty period specified by the
PenaltyTimeForPhyChFail(BSC6900,BSC6910) parameter, the UE is prohibited
from being handed over to any neighboring GSM cell. The
IRATHO.FailOutCS.PhyChFail(BSC6900,BSC6910) counter provides the
number of handover failures.
The InterRatPhyChFailNum(BSC6900,BSC6910) and
PenaltyTimeForPhyChFail(BSC6900,BSC6910) parameters are set by running the
cell-level command ADD UCELLINTERRATHOCOV or RNC-level command
SET UINTERRATHONCOV.
l For UEs that are processing PS services:
Upon receipt of a CELL CHANGE ORDER FROM UTRAN FAILURE message from
the UE, the RNC performs the following operations:
Terminates the handover procedure and enables the UE to continue processing the
PS services in the source cell.
Starts a penalty timer. During the penalty period, the RNC prohibits the UE from
being handed over to the target cell again.
If the PERFENH_INTERRAT_PENALTY_50_SWITCH check box under the
PerfEnhanceSwitch parameter in the SET UCORRMPARA command is selected,
the penalty duration is 50s. Otherwise, the penalty duration is 30s.
If the number of handover failures caused by physical channel failures reaches the
value of the InterRatPhyChFailNum(BSC6900,BSC6910) parameter, the RNC
starts another penalty timer. During the penalty period specified by the
PenaltyTimeForPhyChFail(BSC6900,BSC6910) parameter, the UE is prohibited
from being handed over to any neighboring GSM cell. The
IRATHO.FailOutPSUTRAN.PhyChFail(BSC6900,BSC6910) counter provides
the number of handover failures.
6 Non-Coverage-based Handover
The inter-frequency cells with the same coverage area have the same CPICH RSCP values.
By measuring the CPICH RSCP of the serving cell, the RNC obtains quality of the cells with
the same coverage area and determines whether to allow a blind handover, which increases
the probability of successful blind handover.
1. The RNC initializes the timer of intra-frequency measurement for blind handover. The
timer is specified by internal algorithm and does not need to be configured.
2. The RNC initiates a periodical intra-frequency measurement.
The measurement report mode is set to periodical report.
The reporting period is BlindHOIntrafreqMRInterval(BSC6900,BSC6910).
The number of measurement reports is
BlindHOIntrafreqMRAmount(BSC6900,BSC6910).
The intra-frequency handover measurement quantity is CPICH RSCP.
The list of measured cells contains only the cells that trigger LDR.
3. After receiving from the UE the intra-frequency measurement reports for conditional
blind handover, the RNC checks whether the following condition is met:
CPICH RSCP of the cell in the measurement report
BlindHOQualityCondition(BSC6900,BSC6910)
If the condition is met, the RNC increments the counter of the number of intra-
frequency measurement reports for blind handover by 1.
If the condition is not met, the RNC does not perform a blind handover to the cell
that triggers LDR and stops intra-frequency measurement for blind handover.
4. When the counter reaches the value of
BlindHOIntrafreqMRAmount(BSC6900,BSC6910), the RNC initiates a blind handover
to the target cell.
If the counter does not reach this value, the RNC waits for the next intra-frequency
measurement report from the UE.
5. If the timer of intra-frequency measurement for blind handover expires, the RNC does
not perform a blind handover to the target cell and stops intra-frequency handover
measurement for blind handover.
If the inter-frequency handover based on coverage or QoS is triggered, the RNC stops the
intra-frequency measurement for conditional blind handover.
When the load of the 3G cell that the UE accesses is higher than the related threshold,
the Load Reshuffling (LDR) algorithm makes a handover decision. For detailed
information of the LDR, see Load Reshuffling in the Load Control Feature Parameter
Description.
l In the measurement phase
The RNC enables the compressed mode and starts the inter-RAT handover measurement.
l In the decision phase
After the UE reports event 3C, the RNC makes a handover decision.
l In the execution phase
The RNC initiates a handover procedure.
where
l MOtherRAT is the measurement value of the cell (in another RAT) in the reporting range.
l CIOOtherRAT is the cell individual offset value of the cell (in another RAT) in the
reporting range, which is equal to the sum of CIO(BSC6900,BSC6910) and
CIOOffset(BSC6900,BSC6910).
l TOtherRAT is the absolute inter-RAT handover threshold. Based on different service types
(CS, PS domain R99 services, or PS domain HSPA services), this threshold can be
configured through the following parameters:
InterRATNCovHOCSThd(BSC6900,BSC6910)
InterRATNCovHOPSThd(BSC6900,BSC6910)
l H3c is HYSTFOR3C(BSC6900,BSC6910), the hysteresis value of event 3C.
indicates the handover attempts made to the same cell or different cells. If the number of
attempts exceeds the parameter value, the RNC does not initiate the handover.
This feature can balance the load between the two systems by transferring some kind of
appropriate services to GSM/GPRS.
l When a single CS service is initially set up by the UE, the RNC allows the 3G-to-2G
service-based handover if CSServiceHOSwitch(BSC6900,BSC6910) is set to ON.
l When a single PS service is initially set up by the UE, the RNC allows the service-based
3G-to-2G handover if PSServiceHOSwitch(BSC6900,BSC6910) is set to ON.
l When CS+PS combined services are initially set up by the UE, the RNC allows the
service-based 3G-to-2G handover if CSPSServiceHOSwitch(BSC6900,BSC6910) is set
to ON.
Except for the triggering phase, the procedure of service-based inter-RAT handover is the
same as that of the load-based inter-RAT handover. For details, see section 6.2 Load-based
Inter-RAT Handover.
When a service is established, the RNC requests the handover to GSM based on the service
type and service handover indications assigned by the CN.
Figure 6-3 shows the indications for load/service-based 3G-to-2G handover of a single CS/PS
service. CS+PS combined services do not support load-based 3G-to-2G handover but support
service-based 3G-to-2G handover. The indications for service-based 3G-to-2G handover of
CS+PS combined services are the same as those for service-based 3G-to-2G handover of a
single CS service.
Figure 6-3 Indications for load/service-based 3G-to-2G handover of a single CS/PS service
When determining whether to initiate a 3G-to-2G handover, the RNC considers the 2G cell
capability (RatCellType(BSC6900,BSC6910)), service required capability
(Req2GCap(BSC6900,BSC6910)) and UE capability.
The following table describes the impacts of different types of capability on handover
decision.
If the capability of all neighboring 2G cells does not meet the requirement, the inter-RAT
measurement will not be triggered.
If the 3G cell is in the basic congestion state, the RNC returns RELOCATION
FAILURE message to the CN to cancel the inter-RAT handover.
For the concept of "basic congestion", see Load Control Feature Parameter Description.
7 HSPA Handover
Handling of Event 1A
After receiving an event 1A report, the RNC proceeds as follows:
l If the number of cells in the active set does not reach the maximum value, the RNC adds
the cell to the active set.
l If the number of cells in the active set reaches the maximum value and
HO_MC_INTRAFREQ_1A_REPLACE_1C_SWITCH under
HoSwitch1(BSC6900,BSC6910) is set to OFF, the RNC does not replace cells in the
active set. If HO_MC_INTRAFREQ_1A_REPLACE_1C_SWITCH is set to ON and
the cell to be replaced in the active set is not the serving cell of the UE, the RNC
determines whether to replace the cell with the best cell in the cell list according to the
rules described in section Intra-Frequency Handover Decision and Execution
Triggered by Event 1A that Serves as a Substitute for Event 1C. If the cell to be
replaced in the active set is the serving cell of the UE, the RNC first initiates a serving
cell change procedure for the UE and then replace the cell in the active set. The
following table lists the replacement rules.
l If the number of cells in the active set reaches the maximum value and
RESERVED_SWITCH_13_BIT27 under RsvSwitch13(BSC6900,BSC6910) is set to
OFF, the RNC does not replace cells in the active set. If
RESERVED_SWITCH_13_BIT27 is set to ON and the cell to be replaced in the active
set is not the serving cell of the UE, the RNC determines whether to replace the cell with
the best cell in the cell list according to the rules described in section Intra-Frequency
Handover Decision and Execution Triggered by Event 1A that Serves as a
Substitute for Event 1C. If the cell to be replaced in the active set is the serving cell of
the UE, the RNC first initiates a serving cell change procedure for the UE and then
replace the cell in the active set. The following table lists the replacement rules.
If... Then...
The best cell in the active set The RNC reconfigures the best cell as the HSDPA
supports HSDPA services serving cell and then replaces the cell in the active set.
If the reconfiguration fails, the RNC reconfigures the
HSDPA service on the DPCH and replaces the cell in the
active set.
The best cell in the active set The RNC reconfigures the HSDPA service on the DPCH
does not support HSDPA and then replaces the cell in the active set.
services
Handling of Event 1B
After receiving an event 1B report, the RNC determines whether to delete a cell.
l If the cell to be deleted is not an HSDPA serving cell, the cell is directly removed.
l If the cell to be deleted is an HSDPA serving cell, then:
If the new best cell supports HSDPA services, the new best cell is reconfigured as
an HSDPA serving cell. If the reconfiguration fails, the HSDPA service is
reconfigured onto the DPCH.
If the new best cell does not support HSDPA services, the HSDPA service is
reconfigured onto the DPCH to ensure service continuity.
Handling of Event 1C
After receiving an event 1C report, the RNC determines whether to replace the worst cell.
l If the cell to be replaced is not an HSDPA serving cell, the cell is directly replaced.
l If the cell to be replaced is an HSDPA serving cell, then:
If the best cell supports HSDPA services, the best cell is reconfigured as an HSDPA
serving cell. If the reconfiguration fails, the HSDPA service is reconfigured onto the
DPCH.
If the best cell does not support HSDPA services, the HSDPA service is
reconfigured onto the DPCH to ensure service continuity.
Handling of Event 1D
After receiving an event 1D report, the RNC proceeds as follows:
l If the downlink service is carried on the HSDPA, then:
If the new best cell in the active set supports HSDPA services and the HSPA
hysteresis timer (HspaTimerLen(BSC6900,BSC6910)) expires, the new best cell is
reconfigured as an HSDPA serving cell.
If the new best cell in the active set does not support HSDPA services, the downlink
service is reconfigured onto the DPCH.
Figure 7-1 shows an example of how to handle event 1D in this situation. Assume that
the UE moves from HSDPA cell 1 to HSDPA cell 2, that the two cells are intra-
frequency neighboring cells, and that all the cells in the active set support HSDPA
services. The RNC updates the HSDPA serving cell according to the MR and keeps the
HSDPA serving cell consistent with the best cell.
Figure 7-1 Intra-frequency handover between HSDPA cells when the best cell changes
l If the downlink service is carried on the DCH, the UE is handed over to the target cell,
and the service is carried on the DCH. After the handover, the RNC may retry to
configure the service on the HS-DSCH. For details, see 7.5 HSPA Retry.
In the execution procedure mentioned above,
CMP_UU_SERV_CELL_CHG_WITH_ASU_SWITCH under the
CmpSwitch(BSC6900,BSC6910) parameter determines whether the update of the active
set and the change of the serving cell are synchronized. This switch is applicable only to
UEs complying with 3GPP Release 6.
If the switch is set to ON, the UE supports the synchronization of the update of the
active set with the change of the serving cell.
If the switch is set to OFF, the UE reconfigures the change of the serving cell by
allocating physical channels after updating the active set.
RAN16.0 introduces the fast HSDPA serving cell change function, which is implemented
during an HSDPA intra-frequency handover. For details about the fast HSDPA serving cell
change function, see Process Optimization Feature Parameter Description.
determines whether a cell change to the HSDPA target cell is allowed if the HSDPA target cell
is in the uplink out-of-synchronization state.
The following describes the three possible scenarios in which an inter-frequency handover
occurs.
If the TPC command is carried on the F-DPCH between the UE and the UTRAN, the SRB
and the TRB are carried on the HS-DSCH. If a cell that does not support the F-DPCH is
added to the active set, all the F-DPCHs are deleted. In addition, new DPCHs between the UE
and all the cells in the active set are set up to carry the SRB and TPC commands.
For details about intra-frequency handover of DC-HSUPA UEs, see DC-HSUPA Feature
Parameter Description.
Handling of Event 1A
If the number of cells in the active set does not reach the maximum value when the RNC
receives an event 1A report, the RNC adds the cell to the active set according to the following
rules.
If... Then...
The number of links in the E-DCH active The RNC adds the target cell to the DCH
set is less than the value of active set and E-DCH active set.
MaxEdchCellInActive-
Set(BSC6900,BSC6910)
The number of links in the E-DCH active The RNC adds the target cell to the DCH
set is equal to the value of active set.
MaxEdchCellInActive-
Set(BSC6900,BSC6910)
If the number of cells in the active set reaches the maximum value and
HO_MC_INTRAFREQ _1A_REPLACE_1C_SWITCH is set to OFF under the
HoSwitch1(BSC6900,BSC6910) parameter when the RNC receives an event 1A report, the
RNC does not replace the cell in the active set. If this switch is set to ON but the target cell
does not support HSUPA services, the RNC initiates replacement of cells in the active set and
adds the cell to the DCH active set. If this switch is set to ON and the target cell supports
HSUPA services, the RNC adds the cell to the active set.
If... Then...
The number of links in the E-DCH active set is The RNC initiates replacement of cells
less than the value of MaxEdchCellInActive- in the active set and adds this cell to
Set(BSC6900,BSC6910) the DCH active set and E-DCH active
set.
The number of links in the E-DCH active set is The RNC initiates replacement of cells
equal to the value of MaxEdchCellInActive- in the active set and adds this cell to
Set(BSC6900,BSC6910) and the cell to be the DCH active set and E-DCH active
replaced is in the E-DCH active set set.
The number of links in the E-DCH active set is The RNC initiates replacement of cells
equal to the value of MaxEdchCellInActive- in the active set and adds this cell to
Set(BSC6900,BSC6910) and the cell to be the DCH active set.
replaced is not in the E-DCH active set.
Handling of Event 1B
If the number of radio links in the DCH active set is larger than one, then:
l If the cell to be removed is not an HSUPA serving cell, the cell is directly removed.
l If the cell to be removed is an HSUPA serving cell, then:
If the new best cell supports HSUPA, the new best cell is reconfigured to be an E-
DCH serving cell.
If the new best cell does not support HSUPA, the uplink service is redirected to the
DCH through the RB reconfiguration.
l If the current service is CS Voice over HSPA and the cell to be removed is an E-DCH
serving cell, then:
If the new best cell supports both HSDPA and HSUPA, the cell is reconfigured to
be an HS-DSCH serving cell or an E-DCH serving cell.
If the new best cell supports HSDPA but not HSUPA, the current service is changed
from CS Voice over HSPA to CS Voice over DCH. If there remain other HSDPA
services, the serving cell should be updated and the new best cell should be the HS-
PDSCH serving cell.
If the new best cell supports neither HSUPA nor HSDPA, the current service is
reconfigured to be CS Voice over DCH.
Whether the cells under the adjacent RNC support CS Voice over HSPA is determined by the
RNC-level parameter CSVoiceoverHSPASuppInd(BSC6900,BSC6910).
After the best cell of a UE changes, if the size of the DCH or E-DCH active set of the new
best cell is different from those of the old best cell, the RNC removes or reconfigures radio
links to adapt to the size and configuration of the new best cell.
Handling of Event 1C
When event 1C is triggered, the UE reports the event-triggered list that contains good cells
and the cells to be replaced, and sequences the cells from the highest to the lowest quality
according to measurement quantity.
If the new cell does not support HSUPA, the cell is added to only the DCH active set.
Handling of Event 1D
If the criteria for intra-frequency hard handover are fulfilled, the RNC performs intra-
frequency hard handover after receiving the event 1D report. If the criteria for intra-frequency
hard handover are not fulfilled, the RNC performs intra-frequency soft handover based on the
measurement report.
If the uplink service is carried on the E-DCH, then:
l If the best cell in the active set supports HSUPA and the HSPA services, and the
handover penalty timer for HSPA services expires, the RNC reconfigures the E-DCH
serving cell as the best cell. The RNC restarts this timer after an HSUPA serving cell
change. The length of the timer is specified by the HspaTimerLen(BSC6900,BSC6910)
parameter.
l If the new best cell in the active set does not support HSUPA, The uplink service is
directed to the DCH through the reconfiguration. If the reconfiguration fails, the service
is still carried on the E-DCH. The UE is connected to the new best cell only on the DCH.
If the uplink service is carried on the DCH, then: The uplink service is still carried on the
DCH. After handover, the RNC may retry to configure the service on E-DCH. For details, see
7.5 HSPA Retry. If the current service is CS Voice over HSPA, then:
If the new best cell supports both HSUPA and HSDPA, the cell is reconfigured to be an HSPA
serving cell. Otherwise, the service is changed from CS Voice over HSPA to CS Voice over
DCH through the reconfiguration.
Triggering of Event 1J
Event 1J is triggered under the following condition:
10 x Log (MNew) + CIONew 10 x Log (MInAS) + CIOInAS + H1j/2
l MNew is the measurement result of the cell not in the E-DCH active set but in the DCH
active set.
l CIONew and CIOInAS refer to the offset of each cell.
l MInAS is the measurement result of the cell in the E-DCH active set with the lowest
measurement result.
l H1J is the hysteresis parameter for event 1J and is determined by
Hystfor1J(BSC6900,BSC6910).
l If the measurement result is CPICH-Ec/N0, MNew and MInAS are expressed as ratios.
l If the measurement result is CPICH-RSCP, MNew and MInAS are expressed in mW.
In Figure 7-5, the hysteresis and the cell individual offsets for all cells equal 0.
The first measurement report is sent when primary CPICH D becomes better than primary
CPICH B. The "cell measurement event result" of the measurement report contains the
information of primary CPICH D and CPICH B.
On the assumption that the E-DCH active set has been updated after the first measurement
report (E-DCH active set is now primary CPICH A and primary CPICH D), the second report
is sent when primary CPICH C becomes better than primary CPICH A. The "cell
measurement event result" of the second measurement report shows that primary CPICH C is
better than primary CPICH A in quality.
l HoSwitch(BSC6900,BSC6910): HO_INTRA_FREQ_RPRT_1J_SWITCH:
measurement control switch for event 1J. When the switch is ON, the UE version is R6
and event 1J is included in the intra-frequency measurement control message.
After receiving the intra-frequency measurement report from the UE, the RNC decides
whether to go to the execution phase, depending on the information in the report.
Handling of Event 1J
Event 1J provides the solution to the issue of how to add an HSUPA cell in a DCH active set
to an E-DCH active set. This event is triggered when a non-active E-DCH but active DCH
primary CPICH becomes better than an active E-DCH primary CPICH.
When event 1J is triggered, the UE reports the event-triggered list that contains good cells and
the cells to be replaced, and sequences the cells from the highest to the lowest quality
according to measurement quantity.
l If the current number of cells in the E-DCH active set is smaller than the value of
MaxEdchCellInActiveSet(BSC6900,BSC6910), the cell where event 1J is triggered is
reconfigured to E-DCH.
l If the current number of cells in the E-DCH active set is equal to the value of
MaxEdchCellInActiveSet(BSC6900,BSC6910), the RNC searches the measurement
report for the non-serving Cell_EDCH with the lowest measured quality in the E-DCH
active set. Then, the uplink of the cell where event 1J is triggered is reconfigured from
DCH to E-DCH, and the uplink of CELL-EDCH is reconfigured from E-DCH to DCH.
Only when all the cells in the E-DCH active set support 2 ms TTI can the services be
configured to the E-DCH with 2 ms TTI. If any cell in the E-DCH active set does not support
2 ms TTI, the services are configured on the E-DCH with 10 ms TTI.
When the uplink service is carried on the E-DCH with 2 ms TTI, if a cell that supports only
10 ms TTI is to be added to the E-DCH active set, the source cell undergoes a radio bearer
reconfiguration to 10 ms TTI. A soft handover to the target cell is performed.
Upon each handover, if a radio link needs to be added, removed, or replaced, the RNC judges
whether all the cells in the E-DCH active set and the UE support 2 ms TTI.
If they all support 2 ms TTI and the uplink service is currently carried on the E-DCH with 10
ms TTI, the RNC reconfigures the service to the E-DCH with 2 ms TTI.
l If the reconfiguration fails, a timer is started for periodic retries to the E-DCH with 2 ms
TTI.
l If the handover is performed before the timer expires, the timer is stopped.
l After the handover, the RNC decides whether to start the timer, based on the handover
result.
During the execution phase, whether to reconfigure the services from E-DCH to DCH
depends on the HSUPA capability of the target cell. After the handover, a decision must be
made about whether to reconfigure the services from DCH to E-DCH.
Table 7-1 describes the three possible scenarios for inter-frequency handover.
Scenario Description
If the current service is CS Voice over HSPA and the target cell supports both HSDPA and
HSUPA, the target cell is reconfigured as an HSPA serving cell. Otherwise, the service of CS
Voice over HSPA must first be reconfigured as CS Voice over DCH.
Whether the target RNC supports CS Voice over HSPA is determined by the parameter
CSVoiceOverHspaSuppInd(BSC6900,BSC6910).
Figure 7-6 Inter-frequency handover from an HSUPA cell to another HSUPA cell
During this procedure, event 2B is triggered. The HSUPA admission request is made for the
target cell by the RNC.
l If the request is accepted, the handover is performed through the physical channel
reconfiguration message.
l If the request is rejected, the RB reconfiguration is implemented, and the services on the
E-DCH are reconfigured for the DCH.
During this procedure, event 2B is triggered, and the target cell does not support HSUPA. The
DCH admission request is made for the target cell. If the request is accepted, the RB
reconfiguration is implemented, and the services on the E-DCH are reconfigured for the DCH.
7.3.1 Overview
The basic mechanisms of handover remain unchanged after the introduction of HSPA+. New
functions are added to handle the scenario where the source cell and target cell support
different HSPA+ technologies or where admission control prevents the UE from using the
preferred technologies.
Whether a neighboring cell supports HSPA+ technologies can be set through the parameter
CellCapContainerFdd(BSC6900,BSC6910).
Figure 7-9 shows the procedure of HSPA+ technology configuration.
l If the target cell supports the same technologies as the source cell and the bearer scheme
allows the target cell to continue using them, the RNC preselects these technologies for
the target cell.
l Otherwise, the RNC preselects the technologies supported by the target cell and used by
the UE in the source cell.
For uplink 16QAM, uplink enhanced L2 and DTX/DRX, the preselection schemes are as
follows:
In this phase, the RNC performs admission control based on the preselected technologies.
The HSPA+ technologies that can be retried are specified by the parameter
RetryCapability(BSC6900,BSC6910).
8 HCS Handover
8.1 Overview
HCS handover (WRFD-021200 HCS) is one type of inter-frequency handover and inter-RAT
handover. HCS handover is based on UE speed estimation, and is also called speed-based
handover.
In a 3G network, hot spots in radio communication may appear with the increase of
subscribers and traffic. This requires more cells to increase the network capacity. More cells
and smaller cell radius lead to more frequent handovers of UEs. For a UE in fast movement,
frequent handovers reduce call quality, increase uplink interference, and increase signaling
load. Here, Hierarchical Cell Structure (HCS) is a mechanism that arranges different cells at
different layers, each layer granted a priority. HCS handover instructs UEs to stay at cells with
different priorities based on speed estimation, increasing the network capacity.
Figure 8-1 shows an HCS example with three layers.
Fast-moving environment
l Micro cell
Densely populated areas
High requirement for capacity
Slow-moving environment
l Pico cell
Indoor coverage
Outdoor blind spot coverage
Slow-moving environment
The pico cell has the highest HCS priority but the smallest coverage and the macro cell has
the lowest HCS priority but the largest coverage.
Based on speed estimation, the RNC instructs a fast-moving UE to select a cell with a lower
HCS priority to decrease the frequency of handovers, and instructs a slow-moving UE to
select a cell with a higher HCS priority to increase the network capacity.
RNC supports the HCS with eight priorities. The priority level of a cell is set by the
HCSPrio(BSC6900,BSC6910) parameter.
To allow HCS handover, the RNC must enable the function through the
HoSwitch(BSC6900,BSC6910): HO_ALGO_HCS_SPEED_EST_SWITCH parameter.
configured. If no, the RNC performs the measurement procedure. If yes, the RNC
performs a non-emergency blind handover to the target cell.
l In the execution phase
The RNC initiates a handover procedure.
If the handover is performed from a macro cell to a micro cell, the RNC starts the
inter-frequency (or inter-RAT) measurement procedure and performs the handover
procedure to the cell with the best quality after receiving event 2C or 3C from the
UE.
If the handover is performed from a micro cell to a macro cell, inter-frequency or
inter-RAT blind handover neighboring cells are configured, and the target cell
allows blind handover (configured through the parameter
BlindHOFlag(BSC6900,BSC6910)), the RNC performs a non-emergency blind
handover to the target cell. If the blind handover fails, the procedure ends.
When a UE enters the CELL_DCH state from the idle mode or CELL_PCH/URA_PCH state,
the RNC estimates the moving speed state of the UE according to the UE Mobility State
Indicator information element (IE) reported by the UE. The speed estimation principles are as
follows:
l A UE can report the UE Mobility State Indicator IE only in the networks complying with 3GPP
Release 7 or later.
l For details about speed estimation and cell reselection parameters for the UEs in idle mode or in the
CELL_PCH/URA_PCH state, see the UE Behaviors in Idle Mode Feature Parameter Description.
After UE enters CELL_DCH state from CELL_PCH/URA_PCH or idle state, based on the
number of changes of the best cell within a specified period, the speed estimation algorithm
estimates the moving speed of the UE. Then, the RNC decides the UE speed.
If frequent changes of the best cell occur, several events 1D for the same cell may be
recorded. This may lead to inaccurate UE speed estimation. Therefore, a mechanism is used
for anti-ping-pong event 1D recording.
For the handover from a cell with a lower HCS priority to a cell with a higher HCS priority
(from a macro cell to a micro cell), the HCS handover uses the measurement and the UE uses
event-triggered report mode.
Triggering of Event 2C
When the signal quality of a non-used frequency is above a certain threshold, the UE reports
event 2C to the RNC.
After the conditions of event 2C are fulfilled and maintained until the parameter
TrigTime2C(BSC6900,BSC6910) is reached, the UE reports the event 2C measurement
report message.
where
l QNoused is the measured quality of the cell that uses the other frequencies.
l TNoused2c is the absolute quality threshold of the cell that uses the other frequencies,
namely, InterFreqNCovHOThdEcN0(BSC6900,BSC6910).
l H2c is the event 2C hysteresis value Hystfor2C(BSC6900,BSC6910).
The inter-layer handover algorithm initiates the corresponding handover based on speed
estimation:
l If the UE is in fast movement, the RNC instructs the UE to select a cell with a lower
HCS priority.
l If the UE is in slow movement, the RNC instructs the UE to select a cell with a higher
HCS priority.
l If the UE is in normal movement, no inter-layer handover occurs.
When the RNC instructs the UE to select a cell with a lower or higher HCS priority, the
neighboring cells whose frequency band is not supported by the UE are not taken into
account. If there are neighboring cells with several candidate frequencies, the RNC selects
one of the frequencies randomly.
l If the UE is located in the overlap between the cell with an higher HCS priority and the
cell with a lower HCS priority, a blind handover is initiated.
1. The RNC selects the neighboring cells with a lower HCS priority level to generate a cell
list. The neighboring cells whose frequency band is not supported by the UE are not
taken into account. If there are neighboring cells with several candidate frequencies, the
RNC selects one of the frequencies randomly.
2. The RNC searches for neighboring cells for blind handover according to
BlindHOFlag(BSC6900,BSC6910)from the cell list generated in step 1.
3. The RNC determines whether the target cell supports the current service. If the target cell
does not support the current service, the RNC does not perform the blind handover.
The target cell can be a UMTS cell or a GSM cell. The priority of an intra-RAT inter-
frequency blind handover is higher than that of an inter-RAT blind handover.
l If the neighboring cell for blind handover is not configured, a measurement is initiated
for cells with a lower HCS priority.
The target cell is decided on the basis of the measurement report from the UE.
The inter-layer handover algorithm initiates a measurement for cells with a higher HCS
priority and then decides the target cell based on the measurement report from the UE.
When a speed-based inter-frequency handover is triggered, the RNC determines first whether
the timer specified by IFAntiPingpangTimerLength(BSC6900,BSC6910) expires.
l If the timer does not expire, the RNC cancels the handover.
l If the timer expires, the RNC performs the handover.
9 Blind Handover
9.1 Overview
Blind handover is triggered without measurement. It is classified into emergent blind
handover and non-emergent blind handover.
l Emergent blind handover is triggered by 1F event that indicates the used frequency
becomes worse. The UE must perform emergent handover to avoid call drops.
l Non-emergent blind handover may be triggered by LDR, DRD, or HCS speed
estimation.
For details about LDR and DRD, see Load Control Feature Parameter Description.
For details about HCS speed estimation, see chapter 8 HCS Handover
The parameter BlindHoFlag(BSC6900,BSC6910) is configured for neighboring cells and
determines whether a blind handover to this cell is allowed. The
BlindHoFlag(BSC6900,BSC6910) parameter in the ADD UINTERFREQNCELL
command and the BlindHoFlag(BSC6900,BSC6910) parameter in the ADD U2GNCELL
command specify whether a cell is considered as a candidate cell for inter-frequency or inter-
RAT blind handover, respectively.
The BlindHoFlag parameter specifies whether a neighboring cell can be used as the candidate
cell of blind handover.
The parameter BlindHOPrio(BSC6900,BSC6910) indicates the blind handover priority of the
cell. The value 0 represents the highest priority.
Currently, Huawei does not support inter-RNC blind handovers.
where
l MOld is the measurement value of the cell that becomes worse.
l T1f is an absolute threshold. It is set through the parameter
IntraAblThdFor1FRSCP(BSC6900,BSC6910) or
IntraAblThdFor1FecNo(BSC6900,BSC6910).
l H1f is the event 1F hysteresis value set through the parameter
Hystfor1F(BSC6900,BSC6910).
NOTE
Inter-frequency and inter-RAT blind handovers are also controlled by the inter-frequency and inter-RAT
handover switches in addition to the blind handover switch.
1. When the inter-frequency or inter-RAT handover switch is not turned on, an inter-
frequency or inter-RAT blind handover cannot be performed after event 1F is received.
The RNC gets the actual best cell from event 1F. If the quality of the best cell meets the
blind handover condition, that is the quality of the best cell is larger than or equal to
BlindHORSCP1FThreshold(BSC6900,BSC6910), the RNC gets neighboring cells for
blind handover of the best cell, and filtrates the cells that belong to the frequency bands
that UEs do not support. If the quality of the best cell is lower than
BlindHORSCP1FThreshold(BSC6900,BSC6910), the UE is at the edge of the network
coverage and the blind handover is not allowed.
2. If there are multiple neighboring cells for blind handover, the RNC chooses the cell must
support all the current services of UE. When there are multiple such cells, the RNC
choose the neighboring cell for blind handover randomly.
If any inter-frequency cell does not meet the above conditions, then the RNC chooses the
inter-RAT cells with the highest priority of blind handover. The blind handover priority of the
cell is specified by the parameter BlindHOPrio(BSC6900,BSC6910).
If an inter-frequency blind handover based on event 1F fails, the RNC takes the same penalty
measures as those for an inter-frequency handover failure. For details, see section 5.8.1 Inter-
Frequency Handover Failure.
10 Handover Protection
10.1 Anti-Ping-Pong
Inter-Frequency Anti-Ping-Pong
After an inter-frequency handover based on coverage or an inter-frequency blind handover
based on event 1F occurs, the RNC starts the anti-ping-pong algorithm to prevent frequent
switching between inter-frequency handovers triggered by different causes.
The inter-frequency anti-ping-pong algorithm is as follows:
l If a coverage-based inter-frequency handover, an inter-frequency blind handover based
on event 1F, or a QoS-based inter-frequency handover succeeds, the RNC starts a timer
specified by the IFHoPingPongTimer(BSC6900,BSC6910) parameter for the UE.
Before the timer expires, the RNC prohibits the UE from reinitiating coverage-
based inter-frequency handovers, inter-frequency blind handovers based on event
1F, or QoS-based inter-frequency handovers.
After the timer expires, the RNC allows the UE to reinitiate coverage-based inter-
frequency handovers, inter-frequency blind handovers based on event 1F, or QoS-
based inter-frequency handovers.
1. When a non-coverage-based inter-frequency handover is triggered, the RNC determines
whether the timer specified by IFAntiPingpangTimerLength(BSC6900,BSC6910)
expires.
If the timer does not expire, the RNC cancels the handover.
If the timer expires, the RNC performs the handover.
When the UE is handed over from 2G to 3G and if any CS domain service exists, the system
increases the hysteresis of event 3A through the parameter
InterRATPingPongHyst(BSC6900,BSC6910) to prevent the UE from the ping-pong
handover between 2G and 3G in the period specified by the parameter
InterRATPingPongTimer(BSC6900,BSC6910). During the penalty time, the previous
periodical report will be changed to the event 3A report. The value 0 indicates that the system
does not take measures to avoid ping-pong handover between 2G and 3G networks.
l After the inter-frequency handover fails, the retry timer for the cell is started.
l After the retry timer expires, the UE makes a handover attempt to the cell again until the
number of retry times exceeds the maximum number of retry times. If the handover
succeeds or two new event 2B reports are received, the periodical retry is stopped.
For the inter-frequency handover based on coverage or QoS, the following two parameters
determine the retry period and the maximum number of retry times:
For the inter-frequency handover based on speed, the following two parameters determine the
retry period and the maximum number of retry times:
The retry timer and maximum number of retry times for coverage-based and QoS-based inter-
RAT handover are:
The retry timer and maximum number of retry times for load-based and service-based inter-
RAT handover are:
The inter-RAT handover retry algorithm involves in the following two signaling procedures:
Otherwise, the related retry timer for the cell is started. After the retry timer expires, the UE
makes a handover attempt to the cell again until the number of retry times exceeds the
maximum number of retry times.
If the handover succeeds or the new event 3A or 3C report is received, the periodical retry is
stopped.
Before the RNC performs handover for the UE that is enjoying the video phone (VP) service,
the RNC initiates multimedia fallback to change the VP service to the Adaptive Multi Rate
(AMR) speech service, that is, to perform the 3G-to-2G handover based on the CS AMR
speech service.
This function has the following requirements for the CN and UE:
l The CN needs to comply with 3GPP Release 6 or a later version so that the RNC can
send an RAB modify message to trigger fallback of a UE from a VP service to an AMR
service.
l The UE needs to comply with 3GPP Release 6 or a later version. However, this function
is only optional, which may not be supported by a UE complying with 3GPP R6 or a
later version.
As specified in section 4.3 Core Network procedure in 3GPP TS 23.172 V10.0.0, the fallback
service of the VP is categorized into the following two types:
l The process of changing multimedia services back to speech services during call setup.
The RNC does not take part in the process. Therefore, the detailed description of fallback
process is not given.
l The process of changing multimedia services back to speech services during the call.
l The RNC decides to send an inter-RAT handover request after receiving periodical
measurement reports of event 1A, 3A, or 3C.
l The service is combined with a VP, and the "Alternative RAB Parameters" in the RAB
ASSIGNMENT message is a valid AMR speech format.
Figure 10-1 Service change procedure for the 3G-to-2G handover in the CS domain
1. The CN sends the SRNC a RANAP RAB ASSIGNMENT REQUEST message to set up
the VP service.
2. During 3G-to-2G handover, the SRNC sends a RANAP RAB MODIFY REQUEST
message to change the VP service to the AMR speech service. In the section 9.1.46 RAB
MODIFY REQUEST and 9.2.1.45 Requested RAB Parameter Values in 3GPP TS
25.413 V6.5.0, the information element (IE) Alternative RAB Configuration Request is
also added to the RAB MODIFY REQUEST message, which enables the RNC to
request the CN to change the VP service to the AMR speech service.
3. The MSC initiates the Bearer Capability (BC) negotiation with the UE.
4. After the negotiation, the RNC is requested to perform service change.
When the multimedia fallback ends, the RNC decides whether to perform the 3G-to-2G
handover according to the current measurements reported by the UE.
The CN initiates the RAB reconfiguration to request both parties to perform the multimedia
fallback. The single VP service falls back to the single AMR speech service. The multi-RAB
service combined with VP falls back to the multi-RAB service combined with AMR. If the
multimedia fallback succeeds, that is, the video phone in the service falls back to speech
successfully, the inter-RAT handover is initiated. Otherwise, the inter-RAT handover fails.
l ReportIntervalfor1A(BSC6900,BSC6910)
l ReportIntervalfor1C(BSC6900,BSC6910)
l ReportIntervalfor1J(BSC6900,BSC6910)
The following parameters specify the number of reporting times of events for periodical
reporting:
l PeriodMRReportNumfor1A(BSC6900,BSC6910)
l PeriodMRReportNumfor1C(BSC6900,BSC6910)
l PeriodMRReportNumfor1J(BSC6900,BSC6910)
When the actual reporting times exceed the set value, the periodical reporting ends.
11.1 Overview
After the active set is updated, the RNC updates the neighboring cell list by using the
neighboring cell combination algorithm according to the status of the active set. This list
includes the new intra-frequency, inter-frequency, and inter-RAT neighboring cells. The
combination methods of intra-frequency handover, inter-frequency handover, and inter-RAT
handover are the same. When the DC-HSUPA independent active set function is enabled, the
RNC maintains independent neighboring cell lists for the primary and secondary carriers and
implements the neighboring cell combination function only for the primary carrier. For details
about the DC-HSUPA independent active set function, see DC-HSUPA Feature Parameter
Description.
If the radio link of the drift RNC (DRNC) is added to the active set, the source RNC (SRNC)
buffers the intra-frequency, inter-frequency, and inter-RAT neighboring cell lists of the DRNC
until the radio link of the DRNC is released.
The neighboring cell combination result is contained in the MEASUREMENT CONTROL
message and sent to the UE, which instructs the UE to perform intra-frequency, inter-
frequency, and inter-RAT measurement and handover procedures.
The maximum number of neighboring cells of a cell that can be configured is as follows:
l The maximum number of intra-frequency neighboring cells is 64, which includes the cell
itself.
NOTE
When the number of configured intra-frequency neighboring cells exceeds 32, the
HO_INTRA_FREQ_DETSET_INTO_ACTSET_SWITCH and
HO_INTRA_FREQ_DETSET_RPRT_SWITCH switches of the HoSwitch(BSC6900,BSC6910)
parameter must be turned on. Otherwise, the RNC will not select these extra intra-frequency neighboring
cells as candidate target cells.
l The maximum number of inter-frequency neighboring cells of single carrier is 32.
l The maximum number of inter-frequency neighboring cells of multi-carrier is 64.
l The maximum number of inter-RAT neighboring cells of multi-carrier is 64
l The maximum number of intra-frequency neighboring cells is 64, which includes the cell
itself.
NOTE
When the number of configured intra-frequency neighboring cells exceeds 32, the
HO_INTRA_FREQ_DETSET_INTO_ACTSET_SWITCH and
HO_INTRA_FREQ_DETSET_RPRT_SWITCH switches of the HoSwitch(BSC6900,BSC6910)
parameter must be turned on. Otherwise, the RNC will not select these extra intra-frequency neighboring
cells as candidate target cells.
l The maximum number of inter-frequency neighboring cells of single carrier is 32.
l The maximum number of inter-frequency neighboring cells of multi-carrier is 64.
l The maximum number of inter-RAT neighboring cells of multi-carrier is 64
The neighboring cells of the same cell in the active set are added according to
Nprio(BSC6900,BSC6910).
If the number of the cells in Sall is more than maximum number of neighboring cells, delete
the neighboring cells whose repeated number in Sall is less. The best cell and its neighboring
cells will not be deleted.
If the RsvSwitch2(BSC6900,BSC6910): RESERVED_SWITCH_2_BIT9 switch is turned on
and the frequency specified by RSVU32PARA1(BSC6900,BSC6910) is the same as the
frequency for the link under the DRNC in the active set, Sall does not include the inter-
frequency neighboring cells under the DRNC.
12.1 Overview
An RNC may fail to configure some neighboring cells in a cell's neighboring cell list. These
neighboring cells include intra-frequency, inter-frequency, and inter-RAT neighboring cells.
The causes of the failures are classified into the following:
l Predictable causes. for example, a cell is added or a cell's frequency or scrambling code
changes.
l Unpredictable causes, for example, a building is demolished, causing changes in cell
coverage.
If the neighboring cell list is not updated in time to adapt to these changes, some neighboring
cells may be missing.
Missing neighboring cells may result in call drops or deteriorated signal quality because UEs
cannot be handed over to appropriate neighboring cells in time. Missing neighboring cell
detection consists of the following:
l Missing intra-frequency neighboring cell detection
l Missing inter-frequency neighboring cell detection
l Missing inter-RAT neighboring cell detection
l When this switch is turned on, missing intra-frequency neighboring cell detection is
enabled. A UE can report both detected set cells and monitored set cells to the RNC,
which then reports the missing intra-frequency neighboring cells to the Nastar or LMT.
l When this switch is turned off, missing intra-frequency neighboring cell detection is
disabled.
13 Compressed Mode
13.1 Overview
Compressed mode control is a mechanism whereby certain idle periods are created in radio
frames during which the UE can perform measurements on other frequencies. The UE must
use the compressed mode if the UE needs to measure the pilot signal strength of an inter-
frequency cell or inter-RAT cell and has a single-frequency receiver only.
Feature Parameter Description. In this situation, blacklisted UEs in compressed mode cannot
initiate HSDPA/HSUPA/HSPA+ services.
During the blacklist setting, set the TAC_FUNC(BSC6900,BSC6910) parameter to
Special_User_Enhance. and select SPECUSER_NO_HSDPACM_SWITCH (for HSDPA),
SPECUSER_NO_HSUPACM_SWITCH (for HSUPA), or
SPECUSER_NO_EHSPACM_SWITCH (for HSPA+) under the
SpecUserFunctionSwitch4(BSC6900,BSC6910) parameter.
The RNC automatically determines the type of compressed mode on the basis of the
spreading factor used in the uplink or the downlink.
l When the downlink spreading factor is greater than or equal to the parameter
DlSFTurnPoint(BSC6900,BSC6910), the SF/2 approach is preferred. Otherwise, the
high layer scheduling is used.
l When the uplink spreading factor is greater than or equal to the parameter
UlSFTurnPoint(BSC6900,BSC6910), the SF/2 approach is preferred. Otherwise, the
high layer scheduling is used.
When an AMR UE starts SF/2 compressed mode, the adjacent code (SF128,13) has been
occupied, which makes the root code word (SF64, SF6) become unavailable. Meanwhile,
code resources in the cell are insufficient, so a halved SF (SF64, 6) is obtained by using an
alternative scrambling code. The original channelisation code (SF128, 12) is reserved to be
used when the compressed mode ends.
decreases throughput of the cell. For this reason, it is recommended that the function of
halving the SF based on channelisation code reallocation be enabled so that an idle
channelisation code of a new brother code instead of an alternative scrambling code is used
when code resources are sufficient.
Figure 13-3 uses the AMR voice service with SF128 as an example to show the code
resource usage before and after the SF is halved by reallocating the channelisation code..
When an AMR UE starts SF/2 compressed mode, the adjacent code (SF128,13) has been
occupied, which makes the root code word (SF64, SF6) become unavailable.Meanwhile, code
resources in the cell are sufficient, so the service is reconfigured to use SF128, 14 and the idle
channelisation code (SF64, 7) will be used by the service in compressed mode to obtain the
halved SF. The original channelisation code (SF128, 14) is reserved to be used when the
compressed mode ends.
The recommended value of the parameter is 10. If the parameter is set to an excessively large
value, a new channelisation code can be allocated even when the code resource is
experiencing a congestion, which causes negative gains to the HSDPA throughput. If the
parameter is set to an excessively small value, the channelisation code cannot be allocated
even when the code resources are sufficient, making it difficult to obtain gains.
When the code words of the cell are not experiencing congestion, this function can reduce the
number of times (VS.CM.DLSF2.AltScramCode.UE.Mean(BSC6900,BSC6910)) that the
alternative scrambling code is used by UEs in SF/2 compressed mode, which decreases
interference to the system and reduces the downlink DPCH power. It increases throughput of
the HSDPA UEs when data service resources are sufficient.
The more UEs using channelisation code reallocation to implement SF/2 compressed mode,
the more DPCH power is saved. In medium-load cells, for example, there are 15 to 30 UEs on
the DCH and compressed mode is started over 300 times, this function can reduce the number
of UEs who use alternative scrambling codes to implement SF/2 compressed mode and it
decreases the downlink R99 DCH transmit power by 0% to 5%, compared with the same
scenario when this function is disabled. If there are always HSDPA UEs with sufficient data
sources throughout the measurement period, the downlink throughput of HSDPA UEs can be
increased by 5% at most.
In addition, this function may slightly increase the number of downlink channelisation code
words used in the cell because it does not use any alternative scrambling code.
l Inter-frequency measurement
l Inter-RAT measurement
l Coexistence of inter-frequency and inter-RAT measurement
l If the parameter is set to INTERFREQ, the RNC allows the UE to perform only inter-
frequency measurement
l If the parameter is set to INTERRAT, the RNC allows the UE to perform only Inter-RAT
measurement.
l If the parameter is set to SIMINTERFREQRAT, the RNC allows the UE to perform both
inter-frequency and inter-RAT measurement.
Each physical frame can provide three to seven timeslots for the inter-frequency or inter-RAT
cell measurement.
HSDPA Compatibility
The parameter HsdpaCMPermissionInd(BSC6900,BSC6910) is used to enable or disable
compressed mode for HSDPA users.
l If this parameter value is TRUE, compressed mode is permitted on HSDPA and HSDPA
can be activated with compressed mode activated.
l If this parameter value is FALSE, H2D is required before compressed mode is activated
for HSDPA services. HSDPA UEs perform neighboring cell measurement in compressed
mode. In addition, HSDPA services cannot be established when compressed mode is
activated.
HSUPA Compatibility
The parameter HsupaCMPermissionInd(BSC6900,BSC6910) decides whether the
compressed mode can be used on HSUPA.
HSPA+ Compatibility
The parameter EHSPACMPermissionInd(BSC6900,BSC6910) indicates whether the
compressed mode can be activated when an HSPA+ service is in progress and whether an
HSPA+ service can be set up when the compressed mode is active.
DC-HSDPA Compatibility
The McHsdpaLteCMPermissionInd(BSC6900,BSC6910) parameter indicates whether the
compressed mode can be activated when a DC-HSDPA service is in progress and whether a
DC-HSDPA service can be set up when the compressed mode is active.
If HSPA+, HSDPA, or HSUPA UEs perform H2D (HS-DSCH to DCH) or E2D (E-DCH to
DCH) channel switchovers before starting the compressed mode, or DC-HSDPA UEs perform
DC-HSDPA to HSDPA channel switchovers before starting the compressed mode, these UEs
can trigger periodic retries to return to the state after channel switchovers are complete.
Periodic DRDs in compressed mode for increasing the rate are controlled by
PS_CMACTIVE_PROCESS_OPT_SWITCH under the PsSwitch(BSC6900,BSC6910)
parameter in the SET UCORRMALGOSWITCH command as follows:
14 Related Features
Impacted Features
Feature ID Feature Name Description
Impacted Features
Feature ID Feature Name Description
Impacted Features
None
Impacted Features
None
Impacted Features
None
Impacted Features
None
15 Network Impact
Network Performance
The Inter Frequency Hard Handover Based on Coverage feature ensures the service continuity
of moving UEs and reduces the number of call drops at the coverage edge.
Network Performance
The Inter Frequency Hard Handover Based on DL QoS feature reduces the number of call
drops caused by reduced downlink quality and ensures the QoS for users.
Network Performance
The Inter Frequency Hard Handover Based on UL QoS feature reduces the number of call
drops caused by reduced downlink quality and ensures the QoS for users.
Network Performance
The Inter Frequency Hard Handover Based on DL QoS feature reduces the number of call
drops caused by reduced downlink quality and ensures the QoS for users.
Network Performance
The Inter Frequency Hard Handover Based on UL QoS feature reduces the number of call
drops caused by reduced downlink quality and ensures the QoS for users.
Network Performance
The HSDPA Mobility Management feature implements all types of handovers between
adjacent cells. This provides continuous coverage and better service quality for HSDPA UEs.
RAN16.0 introduces the fast HSDPA serving cell change function, which has the following
impacts on network performance:
l The delay of HSDPA serving cell change is shortened by about 400 ms. (The delay of
HSDPA serving cell change is the interval from the time when the RNC sends the PH
CH RECFG message to the time when the RNC receives the PH CH RECFG CMP
message.)
l The HSDPA throughput is increased by 10% to 15%.
l The success rate of HSDPA serving cell changes is increased by 5% to 10%.
16 Engineering Guidelines
16.1.1 Requirements
l Dependencies on Hardware
Not supported by Micro base stations.
l Dependencies on Other Features
This feature does not depend on other features.
l License
This feature is not under license control.
16.1.2 Activation
Step 1 Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration:
UMTS Radio Global Configuration Express > Connection_Oriented RRM Switch
Configuration > Connection Oriented Algorithm Switches; CME batch modification center:
Modifying RNC Parameters in Batches). In this step, select
HO_INTRA_FREQ_SOFT_HO_SWITCH under HandOver Switch to enable soft
handover.
Step 2 Run the RNC MML command SET UHOCOMM (CME single configuration: UMTS Radio
Global Configuration Express > HandOver Parameter Configuration > RNC Oriented
Handover Algorithm Common Parameters; CME batch modification center: Modifying RNC
Parameters in Batches) to set Softer handover combination indicator switch to MAY or
MUST.
Step 3 Run the RNC MML command ADD UINTRAFREQNCELL (CME single configuration:
UMTS Cell Configuration Express > Neighboring Cell > Intra-frequency Neighboring Cell;
CME batch modification center: not supported) to add an intra-frequency neighboring cell.
Step 4 Run the RNC MML command SET UINTRAFREQHO (CME single configuration: UMTS
Radio Global Configuration Express > HandOver Parameter Configuration > RNC Oriented
----End
----End
16.1.5 Deactivation
Run the RNC MML command SET UHOCOMM (CME single configuration: UMTS Radio
Global Configuration Express > HandOver Parameter Configuration > RNC Oriented
Handover Algorithm Common Parameters; CME batch modification center: Modifying RNC
Parameters in Batches) to set Softer handover combination indicator switch to
MUST_NOT.
16.2.1 Requirements
l Dependencies on Hardware
This feature does not have any special requirements for hardware.
16.2.2 Activation
Step 1 Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration:
UMTS Radio Global Configuration Express > Connection_Oriented RRM Switch
Configuration > Connection Oriented Algorithm Switches; CME batch modification center:
Modifying RNC Parameters in Batches) to enable soft handover.
Step 2 Run the RNC MML command ADD UINTRAFREQNCELL (CME single configuration:
UMTS Cell Configuration Express > Neighboring Cell > Intra-frequency Neighboring Cell;
CME batch modification center: not supported) to add an intra-frequency neighboring cell.
Step 3 Run the RNC MML command SET UINTRAFREQHO (CME single configuration: UMTS
Radio Global Configuration Express > HandOver Parameter Configuration > RNC Oriented
Intra-frequency Handover Measurement Algorithm Parameters; CME batch modification
center: Modifying RNC Parameters in Batches) to set the parameter related to handover.
----End
----End
16.2.5 Deactivation
Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration:
UMTS Radio Global Configuration Express > Connection_Oriented RRM Switch
Configuration > Connection Oriented Algorithm Switches; CME batch modification center:
Modifying RNC Parameters in Batches) to set Softer handover combination indicator to
disable the soft handover.
16.3.1 Requirements
l Dependencies on Hardware
This feature does not have any special requirements for hardware.
l Dependencies on Other Features
This feature does not depend on other features.
l License
This feature is not under license control.
l Other Requirements
The Iur interface is configured between adjacent RNCs.
16.3.2 Activation
Step 1 Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration:
UMTS Radio Global Configuration Express > Connection_Oriented RRM Switch
Configuration > Connection Oriented Algorithm Switches; CME batch modification center:
Modifying RNC Parameters in Batches) to enable soft handover.
Step 2 Run the RNC MML command ADD UNRNC (CME single configuration: IUR Configuration
Express > Neighbouring RNC > Neighboring RNC; CME batch modification center: not
supported) or MOD UNRNC (CME single configuration: IUR Configuration Express >
Neighbouring RNC > Neighboring RNC; CME batch modification center: not supported) to
enable cross-Iur soft handover.
Step 3 Run the RNC MML command ADD UEXT3GCELL (CME single configuration: Object
Group > UMTS Service Configuration and Maintenance Management > External Cell
Configuration > RNC 3G External Cell; CME batch modification center: Modifying RNC
External Cell Parameters in Batches) to add a neighboring RNC cell.
Step 4 Run the RNC MML command ADD UINTRAFREQNCELL (CME single configuration:
UMTS Cell Configuration Express > Neighboring Cell > Intra-frequency Neighboring Cell;
CME batch modification center: not supported) to add an intra-frequency neighboring cell.
Step 5 Run the RNC MML command SET UINTRAFREQHO (CME single configuration: UMTS
Radio Global Configuration Express > HandOver Parameter Configuration > RNC Oriented
Intra-frequency Handover Measurement Algorithm Parameters; CME batch modification
center: Modifying RNC Parameters in Batches) to set the parameter related to handover.
----End
Step 2 Set parameters in the areas Cell Config, Uu Message Type, and Save File. Then, click
Submit.
Step 3 Both UE1 and UE2 are in idle mode and camp on the CELL1.
Step 5 UE1 moves from CELL1 to CELL2, through the Trace Data, it can be observed that RNC1
sends the RRC_ACTIVE_SET_UPDATE message to UE1, and UE1 sends the
RRC_ACTIVE_SET_UPDATE_CMP message to RNC1.
----End
16.3.5 Deactivation
Run the RNC MML command MOD UNRNC (CME single configuration: IUR
Configuration Express > Neighbouring RNC > Neighboring RNC; CME batch modification
center: not supported) to disable the cross-Iur soft handover.
16.4.1 Requirements
l Dependencies on Hardware
This feature does not have any special requirements for hardware.
l Dependencies on Other Features
This feature does not depend on other features.
l License
This feature is not under license control.
16.4.2 Activation
Step 1 Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration:
UMTS Radio Global Configuration Express > Connection_Oriented RRM Switch
Configuration > Connection Oriented Algorithm Switches; CME batch modification center:
Modifying RNC Parameters in Batches) to select HO_INTRA_FREQ_HARD_HO_SWITCH
from the HandOver switch list.
Step 2 Run the RNC MML command ADD UINTRAFREQNCELL (CME single configuration:
UMTS Cell Configuration Express > Neighboring Cell > Intra-frequency Neighboring Cell;
CME batch modification center: not supported) to add an intra-frequency or inter-RNC
neighboring cell.
Step 3 If cross-Iur hard handover is required, add the neighboring RNC and neighboring RNC cell.
Run the RNC MML command ADD UNRNC (CME single configuration: IUR Configuration
Express > Neighbouring RNC > Neighboring RNC; CME batch modification center: not
supported) to add a neighboring RNC. Run the RNC MML command ADD UEXT3GCELL
(CME single configuration: Object Group > UMTS Service Configuration and Maintenance
Management > External Cell Configuration > RNC 3G External Cell; CME batch
modification center: Modifying RNC External Cell Parameters in Batches) to add a
neighboring RNC cell. Run the RNC MML command ADD UINTRAFREQNCELL (CME
single configuration: UMTS Cell Configuration Express > Neighboring Cell > Intra-
frequency Neighboring Cell; CME batch modification center: not supported) to set the
neighboring relationships.
Step 4 Run the RNC MML command SET UINTRAFREQHO (CME single configuration: UMTS
Radio Global Configuration Express > HandOver Parameter Configuration > RNC Oriented
Intra-frequency Handover Measurement Algorithm Parameters; CME batch modification
center: Modifying RNC Parameters in Batches) to set the parameter related to handover.
----End
Step 2 Set parameters in the areas Cell Config, Uu Message Type, and Save File. Then, click
Submit.
Step 3 Both UE1 and UE2 are subscribed in HLR to support speech service.
Step 4 4. Both UE1 and UE2 are in idle mode and camp on the CELL1.
Step 6 UE1 moved from CELL1 to CELL2, through the Trace Date, it can be observed
RRC_MEAS_RPRT message with 1D event that UE1 sends to RNC1.
----End
16.4.5 Deactivation
Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration:
UMTS Radio Global Configuration Express > Connection_Oriented RRM Switch
Configuration > Connection Oriented Algorithm Switches; CME batch modification center:
Modifying RNC Parameters in Batches) to deselect
HO_INTRA_FREQ_HARD_HO_SWITCH from the Handover switch list.
16.5.1 Requirements
l Dependencies on Hardware
This feature does not have any special requirements for hardware.
l Dependencies on Other Features
The feature WRFD-010612 HSUPA Introduction Package must be configured before this
feature is activated.
l License
This feature is controlled by the license for the WRFD-010612 HSUPA Introduction
Package. For details about this license, see HSUPA Feature Parameter Description.
16.5.2 Activation
The methods of activating intra-frequency, inter-frequency, and inter-RAT handovers are the
same for HSUPA users and R99 users. For the activation procedures for configuring HSUPA
Mobility Management, see the following sections:
l 16.4 WRFD-020301 Intra Frequency Hard Handover
l 16.8 WRFD-020302 Inter Frequency Hard Handover Based on Coverage
l 16.9 WRFD-020304 Inter Frequency Hard Handover Based on DL QoS
16.5.4 Deactivation
This feature does not need to be deactivated.
16.6.1 Requirements
l Dependencies on Hardware
Dependencies on RNC Hardware
This feature does not depend on the RNC hardware.
Dependencies on NodeB Hardware
The BBU3900 is configured with the WBBPb, WBBPd, or WBBPf board.
l Dependencies on Other Features
The configurations of the features on which this feature depends are complete. This
feature depends on the WRFD-010614 HSUPA Phase 2 feature.
l License
This feature is controlled by the license for the WRFD-01061403 HSUPA 2ms TTI. For
details about this license, see HSUPA Feature Parameter Description.
16.6.2 Activation
This feature is license controlled. It takes effect after its license is activated. For details about
how to activate the license, see License Management Feature Parameter Description.
16.6.4 Deactivation
This feature does not need to be deactivated.
16.7.1 Requirements
l Dependencies on hardware
This feature does not have any special requirements for hardware.
l Dependencies on other features
This feature does not depend on other features.
l License
For details about how to activate the license, see License Management Feature
Parameter Description.
If RAN Sharing or MOCN is enabled, the licensed value is allocated among the primary
and secondary operators according to the value of the "License Allocation for Multiple
Operators parameter".
Method 6: In RAN Sharing scenarios, a feature is activated for the primary and
secondary operators separately. In MOCN scenarios, a feature is activated only for the
primary operator. The licensed values can be set by running the RNC MML command
SET LICENSE.
l Other requirements
To enable videophone services to fall back to voice services, the MSC and UE must
comply with 3GPP Release 6. For details, see section 4.3 Core Network procedure
in 3GPP TS 23.172 V10.0.0.
Certain UEs may not support this feature. It is good practice to blacklist such UEs
for the feature so that the feature will not take effect for these UEs. For details about
how to blacklist such UEs, see Terminal Black List Feature Parameter Description.
During the blacklist setting for the feature, set TAC_FUNC(BSC6900,BSC6910) to
Special_User_Enhance and select RESERVED_SWITCH_BIT30 (inter-
frequency) or RESERVED_SWITCH_BIT31 (inter-RAT) under the
RsvSwitch(BSC6900,BSC6910) parameter.
16.7.2 Activation
Step 1 Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration:
UMTS Radio Global Configuration Express > Connection_Oriented RRM Switch
Configuration > Connection Oriented Algorithm Switches; CME batch modification center:
Modifying RNC Parameters in Batches).
In this step, select the following check boxes under the HoSwitch(BSC6900,BSC6910)
parameter:
l HO_ALGO_HCS_SPEED_EST_SWITCH
l HO_INTRA_FREQ_SOFT_HO_SWITCH
l HO_INTER_FREQ_HARD_HO_SWITCH
l HO_INTER_RAT_PS_OUT_SWITCH
l HO_INTER_RAT_CS_OUT_SWITCH
In this step, select the CMP_DL_LOAD_BALANCE_SWITCH check box under the
Compatibility Switch2 parameter.
Step 2 Run the RNC MML command ADD UCELLHCS (CME single configuration: UMTS Cell
Configuration Express > Cell Parameters > Cell HCS Parameters; CME batch modification
center: Modifying UMTS Cell Parameters in Batches). In this step, set Use of HCS to USED.
Step 3 Set the HCS parameters for different types of neighboring cells as follows:
l Run the RNC MML command ADD UINTRAFREQNCELL (CME single
configuration: UMTS Cell Configuration Express > Neighboring Cell > Intra-frequency
Neighboring Cell; CME batch modification center: not supported) to add an intra-
frequency neighboring cell and set the HCS parameters.
l Run the RNC MML command ADD UINTERFREQNCELL (CME single
configuration: UMTS Cell Configuration Express > Neighboring Cell > Inter-frequency
Neighboring Cell; CME batch modification center: not supported) to add an inter-
frequency neighboring cell and set the HCS parameters.
l Run the RNC MML command ADD U2GNCELL (CME single configuration: UMTS
Cell Configuration Express > Neighboring Cell > GSM Neighboring Cell; CME batch
modification center: not supported) to add an inter-RAT neighboring GSM cell and set
the HCS parameters.
Step 4 For the cells whose HCS parameters have been set, run the RNC MML command ADD
UCELLHCSHO (CME single configuration: UMTS Cell Configuration Express > Cell
Parameters > Cell Oriented HCS Handover Algorithm Parameters; CME batch modification
center: Modifying UMTS Cell Parameters in Batches). In this step, set SpdEstSwitch to ON.
Step 5 Run the RNC MML command SET UHCSHO (CME single configuration: UMTS Radio
Global Configuration Express > HandOver Parameter Configuration > RNC Oriented HCS
----End
Step 1 If the moving speed of a UE is higher than the fast-moving handover threshold (the number of
1D events reported by the UE in the specified period reaches the preset number), an inter-
frequency or inter-RAT HCS handover is triggered.
Step 2 If the moving speed of a UE is lower than the slow-moving handover threshold (the number
of 1D events reported by the UE in the specified period is less than the slow-moving handover
threshold), slow-moving HCS handover measurement is triggered, and a slow-moving inter-
frequency or inter-RAT HCS handover is performed.
Step 4 If an inter-frequency blind handover is triggered, check whether the handover is triggered by
using a RRC_PH_CH_RECFG message on the Uu interface on the RNC LMT. If the
handover is triggered by using the message, this feature is activated.
Step 5 If an inter-RAT blind handover is triggered, check whether 3G-to-2G handovers are
performed on the Uu and Iu interfaces on the RNC LMT. If 3G-to-2G handovers are
performed, this feature is activated.
----End
To check whether a videophone service has fallen back to a voice service after being handed
over to the GSM network, perform the following steps:
Step 1 Start Iu Interface Trace and Uu Interface Trace on the RNC LMT.
Step 2 After video phone services are established, check in the Uu Interface Trace dialog box that
the UE sends to the RNC an RRC_MEAS_RPRT message, which contains the 3A report.
Step 3 In the Iu Interface Trace dialog box, check that the RNC sends an RAB_MODIFY_REQ
message to the CN. In the RAB_MODIFY_REQ message, the value of the IE
alternativeRABConfigurationRequest is alternative-RAB-configuration-Requested.
----End
16.7.5 Deactivation
Step 1 Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration:
UMTS Radio Global Configuration Express > Connection_Oriented RRM Switch
Configuration > Connection Oriented Algorithm Switches; CME batch modification center:
Modifying RNC Parameters in Batches). In this step, deselect
HO_ALGO_HCS_SPEED_EST_SWITCH from the HoSwitch parameter.
Step 2 Run the RNC MML command MOD UCELLHCS (CME single configuration: UMTS Cell
Configuration Express > Cell Parameters > Cell HCS Parameters; CME batch modification
center: Modifying UMTS Cell Parameters in Batches). In this step, set Use of HCS to
NOT_USED.
Step 3 Run the RNC MML command MOD UCELLHCSHO (CME single configuration: UMTS
Cell Configuration Express > Cell Parameters > Cell Oriented HCS Handover Algorithm
Parameters; CME batch modification center: Modifying UMTS Cell Parameters in Batches).
In this step, set SpdEstSwitch to OFF.
----End
16.8.3 Requirements
l Dependencies on hardware
This feature does not depend on the hardware.
l Dependencies on other features
This feature does not depend on other features.
l License
For details about how to activate the license, see License Management Feature
Parameter Description.
If RAN Sharing or MOCN is enabled, the licensed value is allocated among the primary
and secondary operators according to the value of the "License Allocation for Multiple
Operators parameter".
Method 6: In RAN Sharing scenarios, a feature is activated for the primary and
secondary operators separately. In MOCN scenarios, a feature is activated only for the
primary operator. The licensed values can be set by running the RNC MML command
SET LICENSE.
l Other requirements
The UE supports relevant measurements and the handover procedure.
Certain UEs may not support this feature. It is good practice to blacklist such UEs
for the feature so that the feature will not take effect for these UEs. For details about
how to blacklist such UEs, see Terminal Black List Feature Parameter Description.
During the blacklist setting for the feature, set TAC_FUNC(BSC6900,BSC6910) to
Special_User_Enhance and select RESERVED_SWITCH_BIT30 under the
RsvSwitch(BSC6900,BSC6910) parameter.
16.8.4 Activation
Step 1 Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration:
UMTS Radio Global Configuration Express > Connection_Oriented RRM Switch
Configuration > Connection Oriented Algorithm Switches; CME batch modification center:
Modifying RNC Parameters in Batches). In this step, select
HO_INTER_FREQ_HARD_HO_SWITCH from the HandOver Switch drop-down list.
Step 2 Run the RNC MML command ADD UINTERFREQNCELL (CME single configuration:
UMTS Cell Configuration Express > Neighboring Cell > Inter-frequency Neighboring Cell;
CME batch modification center: not supported) to add an inter-frequency neighboring cell.
Step 3 Run the RNC MML command ADD UCELLINTERFREQHOCOV (CME single
configuration: UMTS Cell Configuration Express > Cell Parameters > Cell Oriented
Coverage Based Inter-frequency Handover Measurement Algorithm Parameters; CME batch
modification center: Modifying UMTS Cell Parameters in Batches) (cell level) or SET
UINTERFREQHOCOV (CME single configuration: UMTS Radio Global Configuration
Express > HandOver Parameter Configuration > RNC Oriented Coverage Based Inter-
frequency Handover Measurement Algorithm Parameters; CME batch modification center:
Modifying RNC Parameters in Batches) (RNC level) to configure parameters related to
coverage-based inter-frequency hard handover.
----End
Step 2 Check whether the RNC has sent the UE an RRC_MEAS_CTRL message and the traced
message contains thresholds for triggering events 2D and 2F and the reporting mode.
Step 3 Attenuate signals in the current cell that the UE accesses to trigger reporting of event 2D by
the UE.
Step 4 Check whether the RNC has sent the UE an RRC_MEAS_RPRT message and the traced
message contains an event 2D measurement report shown in Figure 16-1.
Step 5 After the event 2D measurement report is reported, check whether the RNC has sent the UE
an RRC_MEAS_CTRL message and the traced message contains the information element
interFrequencyMeasurement, as shown in Figure 16-2.
Step 6 After the inter-frequency measurement control message is reported, check whether the RNC
has sent the UE an RRC_PH_CH_RECFG message, and the UE has sent the RNC
RRC_PH_CH_RECFG_CMP message, as shown in Figure 16-3 and Figure 16-4.
----End
16.8.7 Deactivation
Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration:
UMTS Radio Global Configuration Express > Connection_Oriented RRM Switch
Configuration > Connection Oriented Algorithm Switches; CME batch modification center:
Modifying RNC Parameters in Batches). In this step, deselect
HO_INTER_FREQ_HARD_HO_SWITCH from HandOver Switch.
When a UE is located at the cell edge, it reports event 2D to trigger a coverage-based inter-
frequency or inter-RAT hard handover.
l If the value of the VS.RRC.MrRpt.2D(BSC6900,BSC6910) counter is small, the
number of coverage-based inter-frequency hard handovers triggered in a measurement
period is small, which indicates that the gains provided by this feature are not obvious.
l If the value of the counter is large and is similar to the value of the
VS.HHO.AttInterFreqOut.CS.TrigRscp(BSC6900,BSC6910),
VS.HHO.AttInterFreqOut.CS.TrigEcNo(BSC6900,BSC6910),
VS.HHO.AttInterFreqOut.PS.TrigRscp(BSC6900,BSC6910),
VS.HHO.AttInterFreqOut.PS.TrigEcNo(BSC6900,BSC6910) counter, the inter-
frequency hard handovers that happened in the measurement period are mainly
coverage-based inter-frequency hard handovers, which indicates that the gains provided
by this feature are obvious.
l If the value of the counter is large and is much greater than the value of the
VS.HHO.AttInterFreqOut.CS.TrigRscp(BSC6900,BSC6910),
VS.HHO.AttInterFreqOut.CS.TrigEcNo(BSC6900,BSC6910),
VS.HHO.AttInterFreqOut.PS.TrigRscp(BSC6900,BSC6910),
VS.HHO.AttInterFreqOut.PS.TrigEcNo(BSC6900,BSC6910) counter, both coverage-
based inter-frequency hard handovers and coverage-based inter-RAT hard handovers
happened in the measurement period.
16.9.3 Requirements
l Dependencies on hardware
This feature does not depend on the hardware.
l Dependencies on other features
The feature WRFD-020302 Inter Frequency Hard Handover Based on Coverage must be
configured before this feature is activated.
l License
For details about how to activate the license, see License Management Feature
Parameter Description.
If RAN Sharing or MOCN is enabled, the licensed value is allocated among the primary
and secondary operators according to the value of the "License Allocation for Multiple
Operators parameter".
Method 6: In RAN Sharing scenarios, a feature is activated for the primary and
secondary operators separately. In MOCN scenarios, a feature is activated only for the
primary operator. The licensed values can be set by running the RNC MML command
SET LICENSE.
l Other requirements
Certain UEs may not support this feature. It is good practice to blacklist such UEs
for the feature so that the feature will not take effect for these UEs. For details about
how to blacklist such UEs, see Terminal Black List Feature Parameter Description.
During the blacklist setting for the feature, set TAC_FUNC(BSC6900,BSC6910) to
Special_User_Enhance and select RESERVED_SWITCH_BIT30 under the
RsvSwitch(BSC6900,BSC6910) parameter.
16.9.4 Activation
Step 1 Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration:
UMTS Radio Global Configuration Express > Connection_Oriented RRM Switch
Configuration > Connection Oriented Algorithm Switches; CME batch modification center:
Modifying RNC Parameters in Batches) to activate the inter-frequency hard handover.
Step 2 Run the RNC MML command ADD UINTERFREQNCELL (CME single configuration:
UMTS Cell Configuration Express > Neighboring Cell > Inter-frequency Neighboring Cell;
CME batch modification center: not supported) to add an inter-frequency neighboring cell.
Step 3 Run the RNC MML command ADD UCELLINTERFREQHOCOV (CME single
configuration: UMTS Cell Configuration Express > Cell Parameters > Cell Oriented
Coverage Based Inter-frequency Handover Measurement Algorithm Parameters; CME batch
modification center: Modifying UMTS Cell Parameters in Batches) (cell level) or SET
UINTERFREQHOCOV (CME single configuration: UMTS Radio Global Configuration
Express > HandOver Parameter Configuration > RNC Oriented Coverage Based Inter-
frequency Handover Measurement Algorithm Parameters; CME batch modification center:
Modifying RNC Parameters in Batches) (RNC level) to configure parameters related to DL-
QoS-based inter-frequency hard handover.
Step 4 Run the RNC MML command SET UQOSACT (CME single configuration: UMTS Radio
Global Configuration Express > QOS Parameter Configuration > RNC-Oriented QoS
Enhancement Algorithm Parameters; CME batch modification center: Modifying RNC
Parameters in Batches) to activate inter-frequency hard handover based on downlink QoS for
BE services.
Step 5 Run the RNC MML command SET UQOSACT (CME single configuration: UMTS Radio
Global Configuration Express > QOS Parameter Configuration > RNC-Oriented QoS
Enhancement Algorithm Parameters; CME batch modification center: Modifying RNC
Parameters in Batches) to activate inter-frequency hard handover based on downlink QoS for
AMR and AMR-WB services.
Step 6 Run the RNC MML command SET UQOSACT (CME single configuration: UMTS Radio
Global Configuration Express > QOS Parameter Configuration > RNC-Oriented QoS
Enhancement Algorithm Parameters; CME batch modification center: Modifying RNC
Parameters in Batches) to activate inter-frequency hard handover based on downlink QoS for
VP services.
----End
----End
16.9.7 Deactivation
Step 1 Run the RNC MML command SET UQOSACT (CME single configuration: UMTS Radio
Global Configuration Express > QOS Parameter Configuration > RNC-Oriented QoS
Enhancement Algorithm Parameters; CME batch modification center: Modifying RNC
Step 2 Run the RNC MML command SET UQOSACT (CME single configuration: UMTS Radio
Global Configuration Express > QOS Parameter Configuration > RNC-Oriented QoS
Enhancement Algorithm Parameters; CME batch modification center: Modifying RNC
Parameters in Batches) to deactivate inter-frequency hard handover based on downlink QoS
for AMR and AMR-WB services.
Step 3 Run the RNC MML command SET UQOSACT (CME single configuration: UMTS Radio
Global Configuration Express > QOS Parameter Configuration > RNC-Oriented QoS
Enhancement Algorithm Parameters; CME batch modification center: Modifying RNC
Parameters in Batches) to deactivate inter-frequency hard handover based on downlink QoS
for VP services.
----End
During the link stability control of CS services and R99 PS BE services, rate reduction and
handover are triggered in sequence. If the number of rate reductions for CS services and R99
PS BE services (VS.AMRWB.ULRateDown(BSC6900,BSC6910),
VS.AMRWB.ULRateDown(BSC6900,BSC6910), or
VS.DCCC.AttDownsizing.UL.Cov(BSC6900,BSC6910)) is small, the uplink quality did not
deteriorate. In this case, do not enable the Inter Frequency Hard Handover Based on UL QoS
feature. If the number of rate reductions for CS services and R99 PS BE services is large,
enable the Inter Frequency Hard Handover Based on UL QoS feature.
16.10.3 Requirements
l Dependencies on hardware
This feature does not depend on the hardware.
l Dependencies on other features
This feature does not depend on other features.
l License
This feature is not under license control.
This feature is not under license control.
l Other requirements
Certain UEs may not support this feature. It is good practice to blacklist such UEs
for the feature so that the feature will not take effect for these UEs. For details about
how to blacklist such UEs, see Terminal Black List Feature Parameter Description.
During the blacklist setting for the feature, set TAC_FUNC(BSC6900,BSC6910) to
Special_User_Enhance and select RESERVED_SWITCH_BIT30 under the
RsvSwitch(BSC6900,BSC6910) parameter.
16.10.4 Activation
Step 1 Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration:
UMTS Radio Global Configuration Express > Connection_Oriented RRM Switch
Configuration > Connection Oriented Algorithm Switches; CME batch modification center:
Modifying RNC Parameters in Batches) to activate the inter-frequency hard handover.
Step 2 Run the RNC MML command ADD UINTERFREQNCELL (CME single configuration:
UMTS Cell Configuration Express > Neighboring Cell > Inter-frequency Neighboring Cell;
CME batch modification center: not supported) to add an inter-frequency neighboring cell.
Step 3 Run the RNC MML command ADD UCELLINTERFREQHOCOV (CME single
configuration: UMTS Cell Configuration Express > Cell Parameters > Cell Oriented
Coverage Based Inter-frequency Handover Measurement Algorithm Parameters; CME batch
modification center: Modifying UMTS Cell Parameters in Batches) (cell level) or SET
UINTERFREQHOCOV (CME single configuration: UMTS Radio Global Configuration
Express > HandOver Parameter Configuration > RNC Oriented Coverage Based Inter-
frequency Handover Measurement Algorithm Parameters; CME batch modification center:
Modifying RNC Parameters in Batches) (RNC level) to configure parameters related to UL-
QoS-based inter-frequency hard handover.
Step 4 Run the RNC MML command SET UQOSACT (CME single configuration: UMTS Radio
Global Configuration Express > QOS Parameter Configuration > RNC-Oriented QoS
Enhancement Algorithm Parameters; CME batch modification center: Modifying RNC
Parameters in Batches) to activate inter-frequency hard handover based on uplink QoS for BE
services.
Step 5 Run the RNC MML command SET UQOSACT (CME single configuration: UMTS Radio
Global Configuration Express > QOS Parameter Configuration > RNC-Oriented QoS
Enhancement Algorithm Parameters; CME batch modification center: Modifying RNC
Parameters in Batches) to activate inter-frequency hard handover based on uplink QoS for
AMR and AMR-WB services.
Step 6 Run the RNC MML command SET UQOSACT (CME single configuration: UMTS Radio
Global Configuration Express > QOS Parameter Configuration > RNC-Oriented QoS
Enhancement Algorithm Parameters; CME batch modification center: Modifying RNC
Parameters in Batches) to activate inter-frequency hard handover based on uplink QoS for VP
services.
----End
Step 3 Ensure that the UE sends an RRC_MEAS_RPRT message to the RNC and the message
contains the event 6A parameter, as shown in Figure 16-6.
Step 4 Ensure that the RNC sends an RRC_MEAS_CTRL message to the NodeB to start event-
triggered or periodic inter-frequency measurement.
----End
16.10.7 Deactivation
Step 1 Run the RNC MML command SET UQOSACT (CME single configuration: UMTS Radio
Global Configuration Express > QOS Parameter Configuration > RNC-Oriented QoS
Enhancement Algorithm Parameters; CME batch modification center: Modifying RNC
Parameters in Batches) to deactivate inter-frequency hard handover based on uplink QoS for
BE services.
Step 2 Run the RNC MML command SET UQOSACT (CME single configuration: UMTS Radio
Global Configuration Express > QOS Parameter Configuration > RNC-Oriented QoS
Enhancement Algorithm Parameters; CME batch modification center: Modifying RNC
Parameters in Batches) to deactivate inter-frequency hard handover based on uplink QoS for
AMR and AMR-WB services.
Step 3 Run the RNC MML command SET UQOSACT (CME single configuration: UMTS Radio
Global Configuration Express > QOS Parameter Configuration > RNC-Oriented QoS
Enhancement Algorithm Parameters; CME batch modification center: Modifying RNC
Parameters in Batches) to deactivate inter-frequency hard handover based on uplink QoS for
VP services.
----End
//Solution 3
SET UQOSACT: AMRQosPerform=YES, UlQosAmrInterFreqHoSwitch=NO,
UlQosWAmrInterFreqHoSwitch=NO;
//Solution 4
SET UQOSACT: VPQosPerform=NO;
SET UQOSACT: VPQosPerform=YES, UlQosVpInterFreqHoSwitch=NO;
16.11.1 Requirements
l Dependencies on hardware
This feature does not depend on the hardware.
l Dependencies on other features
This feature does not depend on other features.
l License
For details about how to activate the license, see License Management Feature
Parameter Description.
If RAN Sharing or MOCN is enabled, the licensed value is allocated among the primary
and secondary operators according to the value of the "License Allocation for Multiple
Operators parameter".
Method 6: In RAN Sharing scenarios, a feature is activated for the primary and
secondary operators separately. In MOCN scenarios, a feature is activated only for the
primary operator. The licensed values can be set by running the RNC MML command
SET LICENSE.
l Other requirements
The UE supports relevant measurements and the handover procedure.
To enable videophone services to fall back to voice services, the MSC and UE must
comply with 3GPP Release 6. For details, see section 4.3 Core Network procedure
in 3GPP TS 23.172 V10.0.0.
Certain UEs may not support this feature. It is good practice to blacklist such UEs
for the feature so that the feature will not take effect for these UEs. For details about
how to blacklist such UEs, see Terminal Black List Feature Parameter Description.
During the blacklist setting for the feature, set TAC_FUNC(BSC6900,BSC6910) to
Special_User_Enhance and select RESERVED_SWITCH_BIT31 under the
RsvSwitch(BSC6900,BSC6910) parameter.
16.11.2 Activation
NOTE
This feature can be batch activated using the CME. For detailed operations, see the following section in
the CME product documentation or online help: Managing the CME > CME Guidelines > Enhanced
Feature Management > Feature Operation and Maintenance.
Step 1 Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration:
UMTS Radio Global Configuration Express > Connection_Oriented RRM Switch
Configuration > Connection Oriented Algorithm Switches; CME batch modification center:
Modifying RNC Parameters in Batches). In this step, select
HO_INTER_RAT_CS_OUT_SWITCH and HO_INTER_RAT_PS_OUT_SWITCH from
the HandOver Switch list.
Step 2 Run the RNC MML command ADD U2GNCELL (CME single configuration: UMTS Cell
Configuration Express > Neighboring Cell > GSM Neighboring Cell; CME batch
modification center: not supported) to add an inter-frequency neighboring GSM cell.
Step 3 Run the RNC MML command ADD UCELLINTERRATHOCOV (CME single
configuration: UMTS Cell Configuration Express > Cell Parameters > Cell Oriented
Coverage Based Inter-rat Handover Measurement Algorithm Parameters; CME batch
modification center: Modifying UMTS Cell Parameters in Batches) (cell level) or SET
UINTERRATHOCOV (CME single configuration: UMTS Radio Global Configuration
Express > HandOver Parameter Configuration > RNC Oriented Coverage based Inter-
rat Handover Measurement Algorithm Parameters; CME batch modification center:
Modifying RNC Parameters in Batches) (RNC level) to configure parameters related to
coverage-based inter-RAT handover to GSM.
Step 4 Run the RNC MML command MOD UTYPRABBASIC (CME single configuration: UMTS
Radio Global Configuration Express > Typical Service Configuration > Basic
Information for Typical Traffic Radio Access Bearer; CME batch modification center: not
supported). In this step, set Service Handover Indicator to
HO_TO_GSM_SHOULD_NOT_BE_PERFORM.
----End
Step 1 Attenuate signals in the current cell that the UE accesses to trigger reporting of event 2D by
the UE.
Step 2 Click to display Uu Interface Trace on the RNC LMT. Under Uu Message Type, select
RRC_MEAS_RPRT.
Step 3 Check whether event 2D shown in Figure 16-7 has been reported in the traced messages.
Step 4 Click to display Uu Interface Trace on the RNC LMT. Under Uu Message Type, select
RRC_MEAS_CTRL.
Step 5 Check in the traced messages whether the RNC has sent the UE an inter-RAT measurement
control message shown in Figure 16-8.
----End
NOTE:
To check whether a videophone service has fallen back to a voice service after being handed
over to the GSM network, perform the following steps:
Step 1 Start Iu Interface Trace and Uu Interface Trace on the RNC LMT.
Step 2 After video phone services are established, check in the Uu Interface Trace dialog box that
the UE sends to the RNC an RRC_MEAS_RPRT message, which contains the 3A report.
Step 3 In the Iu Interface Trace dialog box, check that the RNC sends an RAB_MODIFY_REQ
message to the CN. In the RAB_MODIFY_REQ message, the value of the IE
alternativeRABConfigurationRequest is alternative-RAB-configuration-Requested.
----End
16.11.5 Deactivation
Step 1 Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration:
UMTS Radio Global Configuration Express > Connection_Oriented RRM Switch
Configuration > Connection Oriented Algorithm Switches; CME batch modification center:
Modifying RNC Parameters in Batches) to deactivate this feature.
Step 2 Run the RNC MML command RMV UCELLINTERRATHOCOV (CME single
configuration: UMTS Cell Configuration Express > Cell Parameters > Cell Oriented
Coverage Based Inter-rat Handover Measurement Algorithm Parameters; CME batch
modification center: not supported) (cell level) or SET UINTERRATHOCOV (CME single
configuration: UMTS Radio Global Configuration Express > HandOver Parameter
Configuration > RNC Oriented Coverage based Inter-rat Handover Measurement Algorithm
Parameters; CME batch modification center: Modifying RNC Parameters in Batches) (RNC
level) to remove or restore the parameters related to coverage-based inter-RAT handover to
GSM.
----End
16.12.1 Requirements
l Dependencies on hardware
This feature does not depend on the hardware.
l Dependencies on other features
The feature WRFD-020303 Inter-RAT Handover Based on Coverage must be configured
before this feature is activated.
l License
For details about how to activate the license, see License Management Feature
Parameter Description.
If RAN Sharing or MOCN is enabled, the licensed value is allocated among the primary
and secondary operators according to the value of the "License Allocation for Multiple
Operators parameter".
16.12.2 Activation
Step 1 (Optional) Run the RNC MML command SET UCORRMALGOSWITCH (CME single
configuration: UMTS Radio Global Configuration Express > Connection_Oriented RRM
Switch Configuration > Connection Oriented Algorithm Switches; CME batch modification
center: Modifying RNC Parameters in Batches). In this step, select
HO_INTER_RAT_PS_OUT_SWITCH under the HandOver Switch parameter.
NOTE
Before activating this feature, perform Step 1 if HO_INTER_RAT_PS_OUT_SWITCH are not turned
on. You can run the RNC MML command LST UCORRMALGOSWITCH to check whether this
switch has been turned on.
Step 2 Run the RNC MML command ADD U2GNCELL (CME single configuration: UMTS Cell
Configuration Express > Neighboring Cell > GSM Neighboring Cell; CME batch
modification center: not supported) to add an inter-RAT neighboring cell.
Step 3 Run the RNC MML command SET UQOSHO (CME single configuration: UMTS Radio
Global Configuration Express > QOS Parameter Configuration > RNC Oriented QoS
Handover Measurement Algorithm Parameters; CME batch modification center: Modifying
RNC Parameters in Batches) to set RNC-level parameters related to Inter-RAT Handover
Based on DL QoS.
Step 4 Run the RNC MML command SET UQOSACT (CME single configuration: UMTS Radio
Global Configuration Express > QOS Parameter Configuration > RNC-Oriented QoS
Enhancement Algorithm Parameters; CME batch modification center: Modifying RNC
Parameters in Batches) to turn on QoS switches for different traffic classes.
----End
Step 2 Ensure that the RNC sends an NBAP_DEDI_MEAS_INIT_REQ message to the NodeB and
the message contains the event E and event F parameters.
Step 3 Ensure that the NodeB sends an NBAP_DEDIC_MEAS_RPRT message to the RNC and the
message contains the event E parameter.
Step 4 Ensure that the RNC sends an RRC_MEAS_CTRL message to the NodeB to start event-
triggered or periodic inter-frequency measurement.
----End
16.12.5 Deactivation
Step 1 Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration:
UMTS Radio Global Configuration Express > Connection_Oriented RRM Switch
Configuration > Connection Oriented Algorithm Switches; CME batch modification center:
Modifying RNC Parameters in Batches). In this step, deselect
HO_INTER_RAT_CS_OUT_SWITCH and HO_INTER_RAT_PS_OUT_SWITCH
under the HandOver Switch parameter.
NOTE
Step 2 Run the RNC MML command SET UQOSACT (CME single configuration: UMTS Radio
Global Configuration Express > QOS Parameter Configuration > RNC-Oriented QoS
Enhancement Algorithm Parameters; CME batch modification center: Modifying RNC
Parameters in Batches) to turn off QoS switches for different traffic classes.
----End
16.13.1 Requirements
l Dependencies on hardware
This feature does not depend on the hardware.
l Dependencies on other features
This feature does not depend on other features.
l License
This feature is not under license control.
l Other requirements
The UE supports relevant measurements and the handover procedure.
Certain UEs may not support this feature. It is good practice to blacklist such UEs
for the feature so that the feature will not take effect for these UEs. For details about
how to blacklist such UEs, see Terminal Black List Feature Parameter Description.
During the blacklist setting for the feature, set TAC_FUNC(BSC6900,BSC6910) to
Special_User_Enhance and select RESERVED_SWITCH_BIT31 under the
RsvSwitch(BSC6900,BSC6910) parameter.
16.13.2 Activation
Step 1 (Optional) Run the RNC MML command SET UCORRMALGOSWITCH (CME single
configuration: UMTS Radio Global Configuration Express > Connection_Oriented RRM
Switch Configuration > Connection Oriented Algorithm Switches; CME batch modification
center: Modifying RNC Parameters in Batches). In this step, select
HO_INTER_RAT_PS_OUT_SWITCH under the HandOver Switch parameter.
NOTE
Before activating this feature, perform Step 1 if HO_INTER_RAT_PS_OUT_SWITCH are not turned
on. You can run the RNC MML command LST UCORRMALGOSWITCH to check whether this
switch has been turned on.
Step 2 Run the RNC MML command ADD U2GNCELL (CME single configuration: UMTS Cell
Configuration Express > Neighboring Cell > GSM Neighboring Cell; CME batch
modification center: not supported) to add an inter-RAT neighboring cell.
Step 3 Run the RNC MML command SET UQOSHO (CME single configuration: UMTS Radio
Global Configuration Express > QOS Parameter Configuration > RNC Oriented QoS
Handover Measurement Algorithm Parameters; CME batch modification center: Modifying
RNC Parameters in Batches) to set RNC-level parameters related to Inter-RAT Handover
Based on UL QoS.
Step 4 Run the RNC MML command SET UQOSACT (CME single configuration: UMTS Radio
Global Configuration Express > QOS Parameter Configuration > RNC-Oriented QoS
Enhancement Algorithm Parameters; CME batch modification center: Modifying RNC
Parameters in Batches) to turn on QoS switches for different traffic classes.
----End
SET UCORRMALGOSWITCH:
HoSwitch=HO_INTER_RAT_CS_OUT_SWITCH-1&HO_INTER_RAT_PS_OUT_SWITCH-1;
SET UQOSACT: BEQosPerform=YES, AMRQosPerform=YES, VPQosPerform=YES,
BeUlAct1=InterRatHO, UlQosAmrInterRatHoSwitch=YES, UlQosWAmrInterRatHoSwitch=YES;
Step 2 Ensure that the RNC sends to the NodeB an NBAP_DEDI_MEAS_INIT_REQ message,
which carries the event E parameter, as shown in Figure 16-9.
Step 3 Ensure that the NodeB reports to the RNC an NBAP_DEDI_MEAS_RPRT message, which
carries the event E parameter, as shown in Figure 16-10.
Step 4 Ensure that the RNC sends to the UE an RRC_MEAS_CTRL message and starts inter-
frequency measurement of the event or period type. Then, check that the corresponding traced
message indicates that the RNC has sent the inter-frequency measurement control message to
the UE, as shown in Figure 16-11.
----End
16.13.5 Deactivation
Step 1 Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration:
UMTS Radio Global Configuration Express > Connection_Oriented RRM Switch
Configuration > Connection Oriented Algorithm Switches; CME batch modification center:
Modifying RNC Parameters in Batches). In this step, deselect
Step 2 Run the RNC MML command SET UQOSACT (CME single configuration: UMTS Radio
Global Configuration Express > QOS Parameter Configuration > RNC-Oriented QoS
Enhancement Algorithm Parameters; CME batch modification center: Modifying RNC
Parameters in Batches) to turn off QoS switches for different traffic classes.
----End
16.14.1 Requirements
l Dependencies on Hardware
The BSC should support the NACC RIM procedure and PS handovers. When RIM
messages are exchanged through the eCoordinator, the RNC must support the RIM
procedure that is implemented through Huawei proprietary eCoordinator.
l Dependencies on Other Features
The configurations of the features on which this feature depends are complete. This
feature is required only when one or more of the following features are enabled:
WRFD-020303 Inter-RAT Handover Based on Coverage
WRFD-020305 Inter-RAT Handover Based on Service
WRFD-020306 Inter-RAT Handover Based on Load
WRFD-021200 HCS (Hierarchical Cell Structure)
l License
This feature is not under license control.
l Other Requirements
The UE must support the NACC procedure and PS handover.
The BSC must support the NACC RIM (RAN Information Management) procedure
and PS handover. When RIM messages are exchanged through the eCoordinator,
the RNC must support the RIM procedure that is implemented through Huawei
proprietary eCoordinator.
The SGSN must support the NACC procedure and PS handover. When RIM
messages are exchanged through the CN, the SGSN must support the NACC
procedure.
If the RIM procedure between the RNC and the eCoordinator is required, the
eCoordinator must support the RIM procedure.
16.14.2 Deployment
For details about how to activate, verify, and deactivate this feature, see the following
sections:
16.15.1 Requirements
l Dependencies on Hardware
This feature does not have any special requirements for hardware.
l Dependencies on Other Features
The configurations of the features on which this feature depends are complete. This
feature depends on the feature WRFD-020308 PS Inter-RAT Handover Phase 2.
l License
For details about how to activate the license, see License Management Feature
Parameter Description.
If RAN Sharing or MOCN is enabled, the licensed value is allocated among the primary
and secondary operators according to the value of the "License Allocation for Multiple
Operators parameter".
Method 6: In RAN Sharing scenarios, a feature is activated for the primary and
secondary operators separately. In MOCN scenarios, a feature is activated only for the
primary operator. The licensed values can be set by running the RNC MML command
SET LICENSE.
l Other Requirements
The UE must support the NACC procedure and comply with 3GPP Release 5 or
later.
The BSC must support the NACC RIM (RAN Information Management)
procedure.
When RIM messages are exchanged through the CN, the SGSN must comply with
3GPP Release 5 or later and support the NACC procedure.
When RIM messages are exchanged through the eCoordinator, the BSC and RNC
must support the RIM procedure that is implemented through eCoordinator.
16.15.2 Activation
Step 1 Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration:
UMTS Radio Global Configuration Express > Connection_Oriented RRM Switch
Configuration > Connection Oriented Algorithm Switches; CME batch modification
center: Modifying RNC Parameters in Batches). In this step, select
HO_INTER_RAT_PS_OUT_SWITCH and
HO_INTER_RAT_PS_3G2G_CELLCHG_NACC_SWITCH under the HandOver switch
parameter and deselect HO_INTER_RAT_PS_3G2G_RELOCATION_SWITCH under the
HandOver switch parameter.
NOTE
Step 2 Run the RNC MML command ADD UEXT2GCELL (CME single configuration: Object
Group > UMTS Service Configuration and Maintenance Management > External Cell
Configuration > RNC 2G External Cell; CME batch modification center: Modifying RNC
External Cell Parameters in Batches)(for new neighboring cell) or MOD UEXT2GCELL
(CME single configuration: Object Group > UMTS Service Configuration and
Maintenance Management > External Cell Configuration > RNC 2G External Cell;
CME batch modification center: Modifying RNC External Cell Parameters in Batches) (for
the existing neighboring cell). In this step, set Inter-RAT cell support RIM indicator to
TRUE.
Step 3 (Optional) If RIM messages are exchanged through Huawei proprietary eCoordinator, run the
RNC MML command SET URRCTRLSWITCH, and select the
RIM_ON_ECO_SWITCH check box under the PROCESSSWITCH5 parameter.
----End
Step 1 Run the RNC MML command LST UCORRMALGOSWITCH and check the settings of
the PS inter-RAT handover, NACC, and Relocation switches.
Step 2 Run the RNC MML command LST UEXT2GCELL and check whether the inter-RAT
neighboring cell supports the RIM procedure.
Step 3 Trace messages over the Iu interface to check whether the RNC has sent a
RANAP_DIR_INFO_TRANSFER message to the CN to request RIM information.
Step 4 Trace messages over the Iu interface to check whether the RNC has received a
RANAP_DIR_INFO_TRANSFER message from the CN as a response to the request
message.
----End
To enable RIM messages to be exchanged through Huawei proprietary eCoordinator, do as
follows:
Step 1 Run the RNC MML command LST UCORRMALGOSWITCH and check the settings of
the PS inter-RAT handover, NACC, and Relocation switches.
Step 2 Run the RNC MML command LST UEXT2GCELL and check whether the inter-RAT
neighboring cell supports the RIM procedure.
Step 3 Run the RNC MML command LST URRCTRLSWITCH and check whether the BSC
supports the RIM procedure that is implemented through the eCoordinator.
Step 4 Check the signaling messages over the Sg interface before the UMTS-to-GSM handover is
performed. If an RNC DIRECT INFORMATION TRANSFER message has been sent to the
eCoordinator and an ECO DIRECT INFORMATION TRANSFER message sent by the
eCoordinator has been received over the Sg interface, the WRFD-02030801 NACC(Network
Assisted Cell Change) feature takes effect.
----End
NOTE
To implement this feature, the UE should support NACC. Therefore, the NACC-supportive UEs are
required for activation.
16.15.5 Deactivation
Step 1 Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration:
UMTS Radio Global Configuration Express > Connection_Oriented RRM Switch
Configuration > Connection Oriented Algorithm Switches; CME batch modification center:
Modifying RNC Parameters in Batches) to set
HO_INTER_RAT_PS_3G2G_CELLCHG_NACC_SWITCH in the HandOver switch
parameter to 0.
Step 2 Run the RNC MML command MOD UEXT2GCELL (CME single configuration: Object
Group > UMTS Service Configuration and Maintenance Management > External Cell
Configuration > RNC 2G External Cell; CME batch modification center: Modifying RNC
External Cell Parameters in Batches) to set Inter-RAT cell support RIM indicator to
FALSE.
Step 3 If RIM messages are exchanged through Huawei proprietary eCoordinator, run the RNC
MML command SET URRCTRLSWITCH, and deselect the RIM_ON_ECO_SWITCH
check box under the PROCESSSWITCH5 parameter.
----End
16.16.1 Requirements
l Dependencies on Hardware
This feature does not have any special requirements for hardware.
l Dependencies on Other Features
The configurations of the features on which this feature depends are complete. This
feature depends on the feature WRFD-020308 PS Inter-RAT Handover Phase 2.
l License
For details about how to activate the license, see License Management Feature
Parameter Description.
If RAN Sharing or MOCN is enabled, the licensed value is allocated among the primary
and secondary operators according to the value of the "License Allocation for Multiple
Operators parameter".
Method 6: In RAN Sharing scenarios, a feature is activated for the primary and
secondary operators separately. In MOCN scenarios, a feature is activated only for the
primary operator. The licensed values can be set by running the RNC MML command
SET LICENSE.
l Other Requirements
The BSC must support the NACC RIM (RAN Information Management)
procedure.
If RIM messages are exchanged through Huawei proprietary eCoordinator, the BSC
and RNC must connect to the same eCoordinator and be able to exchange RIM
messages with the eCoordinator.
16.16.2 Activation
Step 1 Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration:
UMTS Radio Global Configuration Express > Connection_Oriented RRM Switch
Configuration > Connection Oriented Algorithm Switches; CME batch modification center:
Modifying RNC Parameters in Batches) to open the following switches in the HandOver
switch parameter:
l HO_INTER_RAT_PS_OUT_SWITCH
l HO_INTER_RAT_PS_3G2G_RELOCATION_SWITCH
Step 2 Run the RNC MML command ADD UEXT2GCELL (CME single configuration: Object
Group > UMTS Service Configuration and Maintenance Management > External Cell
Configuration > RNC 2G External Cell; CME batch modification center: Modifying RNC
External Cell Parameters in Batches) to add a neighboring GSM cell to the UMTS coverage
and to set the Inter-RAT cell support PS HO indicator parameter to TRUE.
Step 3 Run the RNC MML command ADD U2GNCELL (CME single configuration: UMTS Cell
Configuration Express > Neighboring Cell > GSM Neighboring Cell; CME batch
modification center: not supported) to add a neighboring GSM cell for the UMTS cell.
Step 4 (Optional) Run the RNC MML command SET UINTERRATHOCOV (CME single
configuration: UMTS Radio Global Configuration Express > HandOver Parameter
Configuration > RNC Oriented Coverage based Inter-rat Handover Measurement Algorithm
Parameters; CME batch modification center: Modifying RNC Parameters in Batches) to set
inter-RAT handover measurement related parameters.
----End
----End
16.16.5 Deactivation
Step 1 Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration:
UMTS Radio Global Configuration Express > Connection_Oriented RRM Switch
Configuration > Connection Oriented Algorithm Switches; CME batch modification center:
Modifying RNC Parameters in Batches) to set
HO_INTER_RAT_PS_3G2G_RELOCATION_SWITCH in the HandOver switch
parameter to 0.
Step 2 Run the RNC MML command MOD UEXT2GCELL (CME single configuration: Object
Group > UMTS Service Configuration and Maintenance Management > External Cell
Configuration > RNC 2G External Cell; CME batch modification center: Modifying RNC
External Cell Parameters in Batches) to set the SuppPSHOFlag parameter to FALSE.
----End
16.17.1 Requirements
l Dependencies on hardware
This feature does not depend on the hardware.
l Dependencies on other features
This feature does not depend on other features.
l License
For details about how to activate the license, see License Management Feature
Parameter Description.
If RAN Sharing or MOCN is enabled, the licensed value is allocated among the primary
and secondary operators according to the value of the "License Allocation for Multiple
Operators parameter".
Method 6: In RAN Sharing scenarios, a feature is activated for the primary and
secondary operators separately. In MOCN scenarios, a feature is activated only for the
primary operator. The licensed values can be set by running the RNC MML command
SET LICENSE.
l Other requirements
To enable videophone services to fall back to voice services, the MSC and UE must
comply with 3GPP Release 6. For details, see section 4.3 Core Network procedure
in 3GPP TS 23.172 V10.0.0.
Certain UEs may not support this feature. It is good practice to blacklist such UEs
for the feature so that the feature will not take effect for these UEs. For details about
how to blacklist such UEs, see Terminal Black List Feature Parameter Description.
During the blacklist setting for the feature, set TAC_FUNC(BSC6900,BSC6910) to
Special_User_Enhance and select RESERVED_SWITCH_BIT31 under the
RsvSwitch(BSC6900,BSC6910) parameter.
16.17.2 Activation
NOTE
This feature can be batch activated using the CME. For detailed operations, see the following section in
the CME product documentation or online help: Managing the CME > CME Guidelines > Enhanced
Feature Management > Feature Operation and Maintenance.
Step 1 Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration:
UMTS Radio Global Configuration Express > Connection_Oriented RRM Switch
Configuration > Connection Oriented Algorithm Switches; CME batch modification center:
Modifying RNC Parameters in Batches). In this step, select
HO_INTER_RAT_CS_OUT_SWITCH and HO_INTER_RAT_PS_OUT_SWITCH from
the HandOver Switch list.
Step 2 Run the RNC MML command ADD UEXT2GCELL (CME single configuration: Object
Group > UMTS Service Configuration and Maintenance Management > External Cell
Configuration > RNC 2G External Cell; CME batch modification center: Modifying RNC
External Cell Parameters in Batches) to add a neighboring GSM cell.
Step 3 Run the RNC MML command ADD U2GNCELL (CME single configuration: UMTS Cell
Configuration Express > Neighboring Cell > GSM Neighboring Cell; CME batch
modification center: not supported) to set neighbor relationships with the neighboring GSM
cell.
Step 4 Run the RNC MML command ADD UCELLHOCOMM (CME single configuration: UMTS
Cell Configuration Express > Cell Parameters > Cell Oriented Handover Common Algorithm
Parameters; CME batch modification center: Modifying UMTS Cell Parameters in Batches).
In this step, set Inter-RAT CS handover switch or Inter-RAT PS handover switch to ON.
Step 5 Run the RNC MML command ADD UCELLINTERRATHONCOV (CME single
configuration: UMTS Cell Configuration Express > Cell Parameters > Cell Oriented
None-Coverage Based Inter-rat Handover Measurement Algorithm Parameters; CME
batch modification center: Modifying UMTS Cell Parameters in Batches) (cell level) or SET
UINTERRATHONCOV (CME single configuration: UMTS Radio Global Configuration
Express > HandOver Parameter Configuration > RNC Oriented None-Coverage based
Inter-rat Handover Measurement Algorithm Parameters; CME batch modification center:
Modifying RNC Parameters in Batches) (RNC level) to configure parameters related to non-
coverage-based inter-frequency handover to GSM.
Step 6 Run the RNC MML command ADD UCELLCOALGOENHPARA, set CS+PS Service
Inter-RAT HO Switch to ON.
Step 7 Run the RNC MML command ADD UOPERALGOSWITCH with
HO_IRAT_SERV_FORBID_SWITCH cleared under the HandOver Switch parameter to
cancel the prohibition on service-based inter-RAT handover for a specified operator.
----End
Step 1 Click to display Uu Interface Trace on the RNC LMT. Under Uu Message Type, select
RRC_MEAS_CTRL.
Step 2 After services are set up, view in the traced messages whether the RNC has sent the UE an
inter-frequency measurement control message shown in Figure 16-12.
----End
To check whether a videophone service has fallen back to a voice service after being handed
over to the GSM network, perform the following steps:
Step 1 Start Iu Interface Trace and Uu Interface Trace on the RNC LMT.
Step 2 After video phone services are established, check in the Uu Interface Trace dialog box that
the UE sends to the RNC an RRC_MEAS_RPRT message, which contains the 3A report.
Step 3 In the Iu Interface Trace dialog box, check that the RNC sends an RAB_MODIFY_REQ
message to the CN. In the RAB_MODIFY_REQ message, the value of the IE
alternativeRABConfigurationRequest is alternative-RAB-configuration-Requested.
----End
16.17.5 Deactivation
Step 1 Run the RNC MML command MOD UCELLHOCOMM (CME single configuration: UMTS
Cell Configuration Express > Cell Parameters > Cell Oriented Handover Common Algorithm
Parameters; CME batch modification center: Modifying UMTS Cell Parameters in Batches).
In this step, set Inter-RAT CS handover switch or Inter-RAT PS handover switch to OFF.
----End
After this feature is activated, videophone services can fall back to voice services after being
handed over to the GSM network.
16.18.1 Requirements
l Dependencies on hardware
This feature does not have any special requirements for hardware.
l Dependencies on other features
If this feature is used for HSDPA or HSUPA load control, the feature WRFD-010610
HSDPA Introduction Package or WRFD-010612 HSUPA Introduction Package has been
configured correspondingly before this feature is activated.
l License
For details about how to activate the license, see License Management Feature
Parameter Description.
If RAN Sharing or MOCN is enabled, the licensed value is allocated among the primary
and secondary operators according to the value of the "License Allocation for Multiple
Operators parameter".
Method 6: In RAN Sharing scenarios, a feature is activated for the primary and
secondary operators separately. In MOCN scenarios, a feature is activated only for the
primary operator. The licensed values can be set by running the RNC MML command
SET LICENSE.
l Other requirements
To enable videophone services to fall back to voice services, the MSC and UE must
comply with 3GPP Release 6. For details, see section 4.3 Core Network procedure
in 3GPP TS 23.172 V10.0.0.
Certain UEs may not support this feature. It is good practice to blacklist such UEs
for the feature so that the feature will not take effect for these UEs. For details about
how to blacklist such UEs, see Terminal Black List Feature Parameter Description.
During the blacklist setting for the feature, set TAC_FUNC(BSC6900,BSC6910) to
Special_User_Enhance and select RESERVED_SWITCH_BIT31 under the
RsvSwitch(BSC6900,BSC6910) parameter.
16.18.2 Activation
NOTE
This feature can be batch activated using the CME. For detailed operations, see the following section in
the CME product documentation or online help: Managing the CME > CME Guidelines > Enhanced
Feature Management > Feature Operation and Maintenance.
Step 1 Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration:
UMTS Radio Global Configuration Express > Connection_Oriented RRM Switch
Configuration > Connection Oriented Algorithm Switches; CME batch modification center:
Modifying RNC Parameters in Batches) to activate the inter-RAT handover. In this step, select
the HO_INTER_RAT_CS_OUT_SWITCH and HO_INTER_RAT_PS_OUT_SWITCH
check boxes under the parameter HandOver Switch.
Step 2 Run the RNC MML command SET UCORRMALGOSWITCH. In this step, select the
HO_INTER_RAT_RNC_SERVICE_HO_SWITCH check box under the HandOver
Switch parameter.
Step 3 Run the RNC MML command MOD UTYPRABBASIC. In this step, set Service Handover
Indicator to HO_TO_GSM_SHOULD_BE_PERFORM.
NOTE
Step 4 Enable the uplink air-interface LDR algorithm by selecting the UL_UU_LDR check box
under the Switch for Cell Load Control parameter in the RNC MML command ADD
UCELLALGOSWITCH.
Step 5 Enable the downlink air-interface LDR algorithm by selecting the DL_UU_LDR check box
under the Switch for Cell Load Control parameter in the RNC MML command ADD
UCELLALGOSWITCH.
Step 6 Enable the cell credit LDR algorithm by selecting the CELL_CREDIT_LDR check box
under the Switch for Cell Load Control parameter in the RNC MML command ADD
UCELLALGOSWITCH.
Step 7 Enable the credit load control algorithm at the NodeB or cell group level by selecting the
NODEB_CREDIT_LDR_SWITCH or LCG_CREDIT_LDR_SWITCH check box under
the load control algorithm switch parameter in the RNC MML command SET
ULDCALGOPARA.
Step 8 Enable the credit load congestion control algorithm at the NodeB or cell group level by
selecting the NODEB_CREDIT_LDR or LCG_CREDIT_LDR check box under the NodeB
LDC algorithm switch parameter in the RNC MML command ADD
UNODEBALGOPARA.
NOTE
Performing 4 to 8 facilitates feature verification during lab tests. On a live network, set the parameters
according to the network plan.
Step 9 Run the RNC MML command ADD UEXT2GCELL (CME single configuration: Object
Group > UMTS Service Configuration and Maintenance Management > External Cell
Configuration > RNC 2G External Cell; CME batch modification center: Modifying RNC
External Cell Parameters in Batches) to add the information about a GSM cell.
Step 10 Run the RNC MML command ADD U2GNCELL (CME single configuration: UMTS Cell
Configuration Express > Neighboring Cell > GSM Neighboring Cell; CME batch
modification center: not supported) to add the GSM cell as a neighboring cell of the UMTS
cell.
Step 11 Run the RNC MML command ADD UCELLLDR (CME single configuration: UMTS Cell
Configuration Express > Cell Parameters > Cell LDR Algorithm Parameters; CME batch
modification center: Modifying UMTS Cell Parameters in Batches) to set the inter-RAT
handover policy for the UMTS cell. In this step, set DL LDR fourth action to
CSInterRatShouldBeLDHO(CS domain inter-rat should be load handover), DL LDR
fifth action to PSInterRatShouldBeLDHO(PS domain inter-rat should be load
handover), UL LDR fourth action to CSInterRatShouldBeLDHO(CS domain inter-rat
should be load handover), and UL LDR fifth action to PSInterRatShouldBeLDHO(PS
domain inter-rat should be load handover).
NOTE
Step 12 Run the RNC MML command MOD UCELLLDM. In this step, set the following parameters
to appropriate values: UL LDR trigger threshold, UL LDR release threshold, DL LDR trigger
threshold, DL LDR release threshold, and DL State Trans Hysteresis threshold.
Step 13 Run the RNC MML command MOD UNODEBLDR. In this step, set UL LDR Credit SF
reserved threshold to an appropriate value for the credit LDR algorithm at the NodeB or cell
group level.
Step 14 Run the RNC MML command SET ULDCPERIOD.
Step 15 In this step, set LDR period timer length to an appropriate value. Run the RNC MML
command ADD UCELLINTERRATHONCOV (CME single configuration: UMTS Cell
Configuration Express > Cell Parameters > Cell Oriented None-Coverage Based Inter-
rat Handover Measurement Algorithm Parameters; CME batch modification center:
Modifying UMTS Cell Parameters in Batches) (at the cell level) or SET
UINTERRATHONCOV (CME single configuration: UMTS Radio Global Configuration
Express > HandOver Parameter Configuration > RNC Oriented None-Coverage based
Inter-rat Handover Measurement Algorithm Parameters; CME batch modification center:
Modifying RNC Parameters in Batches) (at the RNC level) to configure parameters related to
non-coverage-based inter-frequency handover to GSM.
----End
Step 1 Initiate Iu interface message tracing and Uu interface message tracing on the RNC LMT.
Step 2 Use a UE in the UMTS cell to call another UE in the same cell. The call is set up successfully.
Step 3 Run the RNC MML command MOD UCELLLDM and set the
UlLdrTrigThd(BSC6900,BSC6910) and DlLdrTrigThd(BSC6900,BSC6910) parameters to
reduce the uplink and downlink LDR threshold, respectively.
l The following messages can be traced on the Iu interface: the
RANAP_RELOCATION_REQUIRED message from the RNC to the CN, and the
RANAP_RELOCATION_COMMAND message from the CN to the RNC.
l The following message can be traced on the Uu interface: the
RRC_HO_FROM_UTRAN_CMD_GSM message from the RNC to the UE.
l The following messages can be traced on the Iu interface: the
RANAP_RELOCATION_REQUIRED message from the RNC to the CN, the
RANAP_RELOCATION_COMMAND message from the CN to the RNC, the
RANAP_IU_RELEASE_COMMAND message from the CN to the RNC, and the
RANAP_IU_RELEASE_COMPLETE message from the RNC to the CN.
----End
To check whether a videophone service has fallen back to a voice service after being handed
over to the GSM network, perform the following steps:
Step 1 Start Iu Interface Trace and Uu Interface Trace on the RNC LMT.
Step 2 After video phone services are established, check in the Uu Interface Trace dialog box that
the UE sends to the RNC an RRC_MEAS_RPRT message, which contains the 3A report.
Step 3 In the Iu Interface Trace dialog box, check that the RNC sends an RAB_MODIFY_REQ
message to the CN. In the RAB_MODIFY_REQ message, the value of the IE
alternativeRABConfigurationRequest is alternative-RAB-configuration-Requested.
----End
16.18.5 Deactivation
Step 1 Run the RNC MML command MOD UCELLLDR (CME single configuration: UMTS Cell
Configuration Express > Cell Parameters > Cell LDR Algorithm Parameters; CME batch
modification center: Modifying UMTS Cell Parameters in Batches) to deactivate the load-
based handover. In this step, set DL LDR fourth action, DL LDR fifth action, UL LDR
fourth action, and UL LDR fifth action to NoAct.
Step 2 Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration:
UMTS Radio Global Configuration Express > Connection_Oriented RRM Switch
Configuration > Connection Oriented Algorithm Switches; CME batch modification center:
Modifying RNC Parameters in Batches) to deactivate the inter-RAT handover. In this step,
deselect the HO_INTER_RAT_CS_OUT_SWITCH and
HO_INTER_RAT_PS_OUT_SWITCH check boxes under the parameter HandOver
Switch.
----End
16.19.1 Requirements
l Dependencies on Hardware
This feature does not have any special requirements for hardware.
l Dependencies on Other Features
This feature is required only when one of the following features is available:
WRFD-020305 Inter-RAT Handover Based on Service
WRFD-020306 Inter-RAT Handover Based on Load
WRFD-021200 HCS (Hierarchical Cell Structure)
WRFD-020400 DRD Introduction Package
WRFD-020308 Inter-RAT Handover Phase 2
l License
For details about how to activate the license, see License Management Feature
Parameter Description.
If RAN Sharing or MOCN is enabled, the licensed value is allocated among the primary
and secondary operators according to the value of the "License Allocation for Multiple
Operators parameter".
Method 6: In RAN Sharing scenarios, a feature is activated for the primary and
secondary operators separately. In MOCN scenarios, a feature is activated only for the
primary operator. The licensed values can be set by running the RNC MML command
SET LICENSE.
l Other Requirements
The CN and BSS must support this feature.
Before deploying this feature, ensure that the Handover Request Acknowledge messages
sent from GSM to UMTS carry load information of GSM cells, because the RNC needs
to determine whether to allow a UMTS-to-GSM handover based on load information of
GSM cells.
16.19.2 Activation
Step 1 Run the RNC MML command SET UCORRMALGOSWITCH (CME single configuration:
UMTS Radio Global Configuration Express > Connection_Oriented RRM Switch
Configuration > Connection Oriented Algorithm Switches; CME batch modification center:
Modifying RNC Parameters in Batches) to enable the inter-RAT handover. In this step, select
HO_INTER_RAT_CS_OUT_SWITCH and HO_INTER_RAT_PS_OUT_SWITCH
through the HandOver Switch.
Step 2 Run the RNC MML command SET UINTERRATHONCOV (CME single configuration:
UMTS Radio Global Configuration Express > HandOver Parameter Configuration > RNC
Oriented None-Coverage based Inter-rat Handover Measurement Algorithm Parameters;
CME batch modification center: Modifying RNC Parameters in Batches) to enable the 3G/2G
common load management function. In this step, select the Send Load Info to GSM Ind and
NCOV Reloc Ind Based on GSM Cell Load.
Step 3 Run the RNC MML command ADD UEXT2GCELL (CME single configuration: Object
Group > UMTS Service Configuration and Maintenance Management > External Cell
Configuration > RNC 2G External Cell; CME batch modification center: Modifying RNC
External Cell Parameters in Batches) to add a GSM cell neighboring to the UMTS coverage.
Step 4 Run the RNC MML command ADD U2GNCELL (CME single configuration: UMTS Cell
Configuration Express > Neighboring Cell > GSM Neighboring Cell; CME batch
modification center: not supported) to set a GSM cell as the UMTS cell's neighboring cell.
----End
Step 2 Run the RNC MML command LST U2GNCELL to ensure the inter-RAT neighboring cell
for the GSM system is added correctly.
----End
NOTE
Consult Huawei engineers about the verification solution to obtain professional technical support.
16.19.5 Deactivation
Run the RNC MML command SET UINTERRATHONCOV (CME single configuration:
UMTS Radio Global Configuration Express > HandOver Parameter Configuration > RNC
Oriented None-Coverage based Inter-rat Handover Measurement Algorithm Parameters;
CME batch modification center: Modifying RNC Parameters in Batches) to set the parameter
Send Load Info to GSM Ind to OFF and the parameter NCOV Reloc Ind based on GSM
cell load to OFF.
16.20.1 Requirements
l Dependencies on Hardware
None
l Dependencies on Other Features
For details, see 14.1 WRFD-01061006 HSDPA Mobility Management.
l License
This feature is controlled by the license for the WRFD-010610 HSDPA Introduction
Package feature. For details about this license, see HSDPA Feature Parameter
Description.
16.20.2 Activation
The methods of activating intra-frequency, inter-frequency, and inter-RAT handovers are the
same for HSDPA UEs and R99 UEs. For the method of activating a function in the
WRFD-01061006 HSDPA Mobility Management feature, see the method of activating the
same function for R99 UEs in following sections:
l 16.1 WRFD-020201 Intra Node B Softer Handover
l 16.2 WRFD-020202 Intra RNC Soft Handover
l 16.3 WRFD-020203 Inter RNC Soft Handover
l 16.4 WRFD-020301 Intra Frequency Hard Handover
l 16.8 WRFD-020302 Inter Frequency Hard Handover Based on Coverage
l 16.9 WRFD-020304 Inter Frequency Hard Handover Based on DL QoS
l Engineering guidelines in Inter Frequency Load Balancing Feature Parameter
Description
l 16.11 WRFD-020303 Inter-RAT Handover Based on Coverage
l 16.12 WRFD-020309 Inter-RAT Handover Based on DL QoS
l 16.17 WRFD-020305 Inter-RAT Handover Based on Service
l 16.18 WRFD-020306 Inter-RAT Handover Based on Load
16.20.4 Deactivation
The methods of deactivating intra-frequency, inter-frequency, and inter-RAT handovers are
the same for HSDPA UEs and non-HSDPA UEs. For the method of activating a function in
the WRFD-01061006 HSDPA Mobility Management feature, see the method of activating the
same function for non-HSDPA UEs in following sections:
16.21.2 Requirements
l Dependencies on hardware
None
l Dependencies on other features
None
l License
This feature is not under license control.
l Other requirements
Certain UEs may not support this function. It is good practice to blacklist such UEs for
the function so that the function will not take effect for these UEs. For details about how
to blacklist such UEs, see Terminal Black List Feature Parameter Description. During
the blacklist setting for the function, set TAC_FUNC(BSC6900,BSC6910) to
Special_User_Enhance and select SPECUSER_NO_HSDPACM_SWITCH (for
HSDPA), SPECUSER_NO_HSUPACM_SWITCH (for HSUPA), or
SPECUSER_NO_EHSPACM_SWITCH (for HSPA+) under the
SpecUserFunctionSwitch4(BSC6900,BSC6910) parameter.
16.21.3 Activation
Step 2 Run the RNC MML command SET UCMCF with DL SF Threshold and UL SF Threshold
set to appropriate values so that the RNC can determine whether to use higher-layer
scheduling or halved SF in compressed mode according to the SFs used in the downlink and
uplink.
Step 3 When SF/2 compressed mode is used, it is recommended that the function of channelisation
code reallocation be used to obtain the halved SF for compressed mode. To enable this
function, run the RNC MML command MOD UCELLALGOSWITCH with DL CM Avoid
Alternative Scrambling Code Switch set to ON.
----End
When configuring compressed mode on the CME, perform a single configuration first, and then perform
a batch modification if required.
Configure the parameters of a single object before a batch modification. Perform a batch modification
before logging out of the parameter setting interface.
2. (Optional) Modify objects in batches on the CME. (CME batch modification center)
To modify objects in batches, click on the CME to start the batch modification
wizard. For instructions on how to perform a batch modification through the CME batch
modification center, press F1 on the wizard interface to obtain online help.
Step 2 Have two CS voice UEs access a cell one by one. In the RRC_RB_RECFG command of the
first UE, query the configured SF. For example, as shown in the following figure, the UE is
configured to use SF128 and the code number is 9.
Step 3 Check whether the RNC sends a measurement control message "RRC_MEAS_CTRL" to the
UE and whether this message contains 2D measurement information.
Step 4 Perform attenuation on signals sent to the UE who first accesses the cell to trigger a 2D
measurement report of the UE.
Step 5 Check whether the RNC has sent an RRC_MEAS_RPRT message to the UE and whether this
message contains an event 2D measurement report, as shown in the following figure.
Step 6 The reallocation channelisation code algorithm will take effect if the following conditions are
met: The RNC sends an RRC_PH_CH_RECFG signaling message to the UE. The downlink
channel codes are reconfigured as different channel numbers. The scrambling code remains
unchanged. As shown in the following figure, the channelisation code is reconfigured as
SF128, the code number is changed to 10, and the scrambling code remains the same.
----End
16.21.5 Deactivation
Both HLS compressed mode and SF/2 compressed mode must be enabled. To deactivate the
channelisation code reallocation algorithm, perform the following operations.
When configuring compressed mode on the CME, perform a single configuration first, and then perform
a batch modification if required.
Configure the parameters of a single object before a batch modification. Perform a batch modification
before logging out of the parameter setting interface.
To modify objects in batches, click on the CME to start the batch modification
wizard. For instructions on how to perform a batch modification through the CME batch
modification center, press F1 on the wizard interface to obtain online help.
17 Parameters
RESERVED_SWITCH_BIT23,
RESERVED_SWITCH_BIT24,
RESERVED_SWITCH_BIT25,
RESERVED_SWITCH_BIT26,
RESERVED_SWITCH_BIT27,
RESERVED_SWITCH_BIT28,
RESERVED_SWITCH_BIT29,
RESERVED_SWITCH_BIT30,
RESERVED_SWITCH_BIT31,
RESERVED_SWITCH_BIT32
Unit: None
Actual Value Range: RESERVED_SWITCH_BIT1,
RESERVED_SWITCH_BIT2,
RESERVED_SWITCH_BIT3,
RESERVED_SWITCH_BIT4,
RESERVED_SWITCH_BIT5,
RESERVED_SWITCH_BIT6,
RESERVED_SWITCH_BIT7,
RESERVED_SWITCH_BIT8,
RESERVED_SWITCH_BIT9,
RESERVED_SWITCH_BIT10,
RESERVED_SWITCH_BIT11,
RESERVED_SWITCH_BIT12,
RESERVED_SWITCH_BIT13,
RESERVED_SWITCH_BIT14,
RESERVED_SWITCH_BIT15,
RESERVED_SWITCH_BIT16,
RESERVED_SWITCH_BIT17,
RESERVED_SWITCH_BIT18,
RESERVED_SWITCH_BIT19,
RESERVED_SWITCH_BIT20,
RESERVED_SWITCH_BIT21,
RESERVED_SWITCH_BIT22,
RESERVED_SWITCH_BIT23,
RESERVED_SWITCH_BIT24,
RESERVED_SWITCH_BIT25,
RESERVED_SWITCH_BIT26,
RESERVED_SWITCH_BIT27,
RESERVED_SWITCH_BIT28,
RESERVED_SWITCH_BIT29,
RESERVED_SWITCH_BIT30,
RESERVED_SWITCH_BIT31,
RESERVED_SWITCH_BIT32
Default Value:
RESERVED_SWITCH_BIT1:0,RESERVED_SWITC
H_BIT2:0,RESERVED_SWITCH_BIT3:0,RESERVE
D_SWITCH_BIT4:0,RESERVED_SWITCH_BIT5:0,
RESERVED_SWITCH_BIT6:0,RESERVED_SWITC
H_BIT7:0,RESERVED_SWITCH_BIT8:0,RESERVE
D_SWITCH_BIT9:0,RESERVED_SWITCH_BIT10:
0,RESERVED_SWITCH_BIT11:0,RESERVED_SWI
TCH_BIT12:0,RESERVED_SWITCH_BIT13:0,RES
ERVED_SWITCH_BIT14:0,RESERVED_SWITCH_
BIT15:0,RESERVED_SWITCH_BIT16:0,RESERVE
D_SWITCH_BIT17:0,RESERVED_SWITCH_BIT18
:
0,RESERVED_SWITCH_BIT19:0,RESERVED_SWI
TCH_BIT20:0,RESERVED_SWITCH_BIT21:0,RES
ERVED_SWITCH_BIT22:0,RESERVED_SWITCH_
BIT23:0,RESERVED_SWITCH_BIT24:0,RESERVE
D_SWITCH_BIT25:0,RESERVED_SWITCH_BIT26
:
0,RESERVED_SWITCH_BIT27:0,RESERVED_SWI
TCH_BIT28:0,RESERVED_SWITCH_BIT29:0,RES
ERVED_SWITCH_BIT30:0,RESERVED_SWITCH_
BIT31:0,RESERVED_SWITCH_BIT32:0
RESERVED_SWITCH_BIT6,
RESERVED_SWITCH_BIT7,
RESERVED_SWITCH_BIT8,
RESERVED_SWITCH_BIT9,
RESERVED_SWITCH_BIT10,
RESERVED_SWITCH_BIT11,
RESERVED_SWITCH_BIT12,
RESERVED_SWITCH_BIT13,
RESERVED_SWITCH_BIT14,
RESERVED_SWITCH_BIT15,
RESERVED_SWITCH_BIT16,
RESERVED_SWITCH_BIT17,
RESERVED_SWITCH_BIT18,
RESERVED_SWITCH_BIT19,
RESERVED_SWITCH_BIT20,
RESERVED_SWITCH_BIT21,
RESERVED_SWITCH_BIT22,
RESERVED_SWITCH_BIT23,
RESERVED_SWITCH_BIT24,
RESERVED_SWITCH_BIT25,
RESERVED_SWITCH_BIT26,
RESERVED_SWITCH_BIT27,
RESERVED_SWITCH_BIT28,
RESERVED_SWITCH_BIT29,
RESERVED_SWITCH_BIT30,
RESERVED_SWITCH_BIT31,
RESERVED_SWITCH_BIT32
Default Value:
RESERVED_SWITCH_BIT1:0,RESERVED_SWITC
H_BIT2:0,RESERVED_SWITCH_BIT3:0,RESERVE
D_SWITCH_BIT4:0,RESERVED_SWITCH_BIT5:0,
RESERVED_SWITCH_BIT6:0,RESERVED_SWITC
H_BIT7:0,RESERVED_SWITCH_BIT8:0,RESERVE
D_SWITCH_BIT9:0,RESERVED_SWITCH_BIT10:
0,RESERVED_SWITCH_BIT11:0,RESERVED_SWI
TCH_BIT12:0,RESERVED_SWITCH_BIT13:0,RES
ERVED_SWITCH_BIT14:0,RESERVED_SWITCH_
BIT15:0,RESERVED_SWITCH_BIT16:0,RESERVE
D_SWITCH_BIT17:0,RESERVED_SWITCH_BIT18
:
0,RESERVED_SWITCH_BIT19:0,RESERVED_SWI
TCH_BIT20:0,RESERVED_SWITCH_BIT21:0,RES
ERVED_SWITCH_BIT22:0,RESERVED_SWITCH_
BIT23:0,RESERVED_SWITCH_BIT24:0,RESERVE
D_SWITCH_BIT25:0,RESERVED_SWITCH_BIT26
:
0,RESERVED_SWITCH_BIT27:0,RESERVED_SWI
TCH_BIT28:0,RESERVED_SWITCH_BIT29:0,RES
ERVED_SWITCH_BIT30:0,RESERVED_SWITCH_
BIT31:0,RESERVED_SWITCH_BIT32:0
RESERVED_SWITCH_2_BIT3,
RESERVED_SWITCH_2_BIT4,
RESERVED_SWITCH_2_BIT5,
RESERVED_SWITCH_2_BIT6,
RESERVED_SWITCH_2_BIT7,
RESERVED_SWITCH_2_BIT8,
RESERVED_SWITCH_2_BIT9,
RESERVED_SWITCH_2_BIT10,
RESERVED_SWITCH_2_BIT11,
RESERVED_SWITCH_2_BIT12,
RESERVED_SWITCH_2_BIT13,
RESERVED_SWITCH_2_BIT14,
RESERVED_SWITCH_2_BIT15,
RESERVED_SWITCH_2_BIT16,
RESERVED_SWITCH_2_BIT17,
RESERVED_SWITCH_2_BIT18,
RESERVED_SWITCH_2_BIT19,
RESERVED_SWITCH_2_BIT20,
RESERVED_SWITCH_2_BIT21,
RESERVED_SWITCH_2_BIT22,
RESERVED_SWITCH_2_BIT23,
RESERVED_SWITCH_2_BIT24,
RESERVED_SWITCH_2_BIT25,
RESERVED_SWITCH_2_BIT26,
RESERVED_SWITCH_2_BIT27,
RESERVED_SWITCH_2_BIT28,
RESERVED_SWITCH_2_BIT29,
RESERVED_SWITCH_2_BIT30,
RESERVED_SWITCH_2_BIT31,
RESERVED_SWITCH_2_BIT32
Default Value:
RESERVED_SWITCH_2_BIT1:0,RESERVED_SWI
TCH_2_BIT2:0,RESERVED_SWITCH_2_BIT3:0,R
ESERVED_SWITCH_2_BIT4:0,RESERVED_SWIT
CH_2_BIT5:0,RESERVED_SWITCH_2_BIT6:0,RES
ERVED_SWITCH_2_BIT7:0,RESERVED_SWITCH
_2_BIT8:0,RESERVED_SWITCH_2_BIT9:0,RESER
VED_SWITCH_2_BIT10:0,RESERVED_SWITCH_
2_BIT11:0,RESERVED_SWITCH_2_BIT12:0,RESE
RVED_SWITCH_2_BIT13:0,RESERVED_SWITCH
_2_BIT14:0,RESERVED_SWITCH_2_BIT15:0,RES
ERVED_SWITCH_2_BIT16:0,RESERVED_SWITC
H_2_BIT17:0,RESERVED_SWITCH_2_BIT18:0,RE
SERVED_SWITCH_2_BIT19:0,RESERVED_SWIT
CH_2_BIT20:0,RESERVED_SWITCH_2_BIT21:0,R
ESERVED_SWITCH_2_BIT22:0,RESERVED_SWIT
CH_2_BIT23:0,RESERVED_SWITCH_2_BIT24:0,R
ESERVED_SWITCH_2_BIT25:0,RESERVED_SWIT
CH_2_BIT26:0,RESERVED_SWITCH_2_BIT27:0,R
ESERVED_SWITCH_2_BIT28:0,RESERVED_SWIT
CH_2_BIT29:0,RESERVED_SWITCH_2_BIT30:0,R
ESERVED_SWITCH_2_BIT31:0,RESERVED_SWIT
CH_2_BIT32:0
RESERVED_SWITCH_2_BIT4,
RESERVED_SWITCH_2_BIT5,
RESERVED_SWITCH_2_BIT6,
RESERVED_SWITCH_2_BIT7,
RESERVED_SWITCH_2_BIT8,
RESERVED_SWITCH_2_BIT9,
RESERVED_SWITCH_2_BIT10,
RESERVED_SWITCH_2_BIT11,
RESERVED_SWITCH_2_BIT12,
RESERVED_SWITCH_2_BIT13,
RESERVED_SWITCH_2_BIT14,
RESERVED_SWITCH_2_BIT15,
RESERVED_SWITCH_2_BIT16,
RESERVED_SWITCH_2_BIT17,
RESERVED_SWITCH_2_BIT18,
RESERVED_SWITCH_2_BIT19,
RESERVED_SWITCH_2_BIT20,
RESERVED_SWITCH_2_BIT21,
RESERVED_SWITCH_2_BIT22,
RESERVED_SWITCH_2_BIT23,
RESERVED_SWITCH_2_BIT24,
RESERVED_SWITCH_2_BIT25,
RESERVED_SWITCH_2_BIT26,
RESERVED_SWITCH_2_BIT27,
RESERVED_SWITCH_2_BIT28,
RESERVED_SWITCH_2_BIT29,
RESERVED_SWITCH_2_BIT30,
RESERVED_SWITCH_2_BIT31,
RESERVED_SWITCH_2_BIT32
Default Value:
RESERVED_SWITCH_2_BIT1:0,RESERVED_SWI
TCH_2_BIT2:0,RESERVED_SWITCH_2_BIT3:0,R
ESERVED_SWITCH_2_BIT4:0,RESERVED_SWIT
CH_2_BIT5:0,RESERVED_SWITCH_2_BIT6:0,RES
ERVED_SWITCH_2_BIT7:0,RESERVED_SWITCH
_2_BIT8:0,RESERVED_SWITCH_2_BIT9:0,RESER
VED_SWITCH_2_BIT10:0,RESERVED_SWITCH_
2_BIT11:0,RESERVED_SWITCH_2_BIT12:0,RESE
RVED_SWITCH_2_BIT13:0,RESERVED_SWITCH
_2_BIT14:0,RESERVED_SWITCH_2_BIT15:0,RES
ERVED_SWITCH_2_BIT16:0,RESERVED_SWITC
H_2_BIT17:0,RESERVED_SWITCH_2_BIT18:0,RE
SERVED_SWITCH_2_BIT19:0,RESERVED_SWIT
CH_2_BIT20:0,RESERVED_SWITCH_2_BIT21:0,R
ESERVED_SWITCH_2_BIT22:0,RESERVED_SWIT
CH_2_BIT23:0,RESERVED_SWITCH_2_BIT24:0,R
ESERVED_SWITCH_2_BIT25:0,RESERVED_SWIT
CH_2_BIT26:0,RESERVED_SWITCH_2_BIT27:0,R
ESERVED_SWITCH_2_BIT28:0,RESERVED_SWIT
CH_2_BIT29:0,RESERVED_SWITCH_2_BIT30:0,R
ESERVED_SWITCH_2_BIT31:0,RESERVED_SWIT
CH_2_BIT32:0
HO_LTE_SERVICE_PSHO_OUT_SWITCH,
HO_INTER_RAT_CS_OUT_SWITCH,
HO_INTER_RAT_PS_3G2G_CELLCHG_NACC_S
WITCH,
HO_INTER_RAT_PS_3G2G_RELOCATION_SWIT
CH, HO_INTER_RAT_PS_OUT_SWITCH,
HO_INTER_RAT_RNC_SERVICE_HO_SWITCH,
HO_INTRA_FREQ_DETSET_INTO_ACTSET_SWI
TCH,
HO_INTRA_FREQ_DETSET_RPRT_SWITCH,
HO_INTRA_FREQ_HARD_HO_SWITCH,
HO_INTRA_FREQ_RPRT_1J_SWITCH,
HO_INTRA_FREQ_SOFT_HO_SWITCH,
HO_MC_MEAS_BEYOND_UE_CAP_SWITCH,
HO_MC_NCELL_COMBINE_SWITCH,
HO_MC_SIGNAL_IUR_INTRA_SWITCH,
HO_MC_SIGNAL_SWITCH,
HO_MC_SNA_RESTRICTION_SWITCH,
HO_LTE_PS_OUT_SWITCH,
HO_LTE_SERVICE_PS_OUT_SWITCH,
HO_H2G_SRVCC_SWITCH,
HO_INTRA_FREQ_HIGHPRIOR_2D2F_SWITCH,
HO_CIO_1D_USED,
HO_HCS_SPD_INI_BSD_UE_SWITCH,
HO_L2U_EMGCALL_SWITCH,
HO_UMTS_TO_LTE_FAST_RETURN_SWITCH,
HO_HHO_WITH_INTRA_FREQ_MR_SWITCH,
HO_MULTIRAB_CSPS_HO_COV_PARA_SWITCH
Default Value:
HO_ALGO_HCS_SPEED_EST_SWITCH:
0,HO_ALGO_LDR_ALLOW_SHO_SWITCH:
1,HO_ALGO_MBMS_FLC_SWITCH:
0,HO_ALGO_OVERLAY_SWITCH:
0,HO_INTER_FREQ_HARD_HO_SWITCH:
0,HO_LTE_SERVICE_PSHO_OUT_SWITCH:
0,HO_INTER_RAT_CS_OUT_SWITCH:
1,HO_INTER_RAT_PS_3G2G_CELLCHG_NACC_
SWITCH:
0,HO_INTER_RAT_PS_3G2G_RELOCATION_SWI
TCH:0,HO_INTER_RAT_PS_OUT_SWITCH:
1,HO_INTER_RAT_RNC_SERVICE_HO_SWITCH:
0,HO_INTRA_FREQ_DETSET_INTO_ACTSET_S
WITCH:
1,HO_INTRA_FREQ_DETSET_RPRT_SWITCH:
1,HO_INTRA_FREQ_HARD_HO_SWITCH:
1,HO_INTRA_FREQ_RPRT_1J_SWITCH:
0,HO_INTRA_FREQ_SOFT_HO_SWITCH:
1,HO_MC_MEAS_BEYOND_UE_CAP_SWITCH:
HO_LTE_SERVICE_PSHO_OUT_SWITCH,
HO_INTER_RAT_CS_OUT_SWITCH,
HO_INTER_RAT_PS_3G2G_CELLCHG_NACC_S
WITCH,
HO_INTER_RAT_PS_3G2G_RELOCATION_SWIT
CH, HO_INTER_RAT_PS_OUT_SWITCH,
HO_INTER_RAT_RNC_SERVICE_HO_SWITCH,
HO_INTRA_FREQ_DETSET_INTO_ACTSET_SWI
TCH,
HO_INTRA_FREQ_DETSET_RPRT_SWITCH,
HO_INTRA_FREQ_HARD_HO_SWITCH,
HO_INTRA_FREQ_RPRT_1J_SWITCH,
HO_INTRA_FREQ_SOFT_HO_SWITCH,
HO_MC_MEAS_BEYOND_UE_CAP_SWITCH,
HO_MC_NCELL_COMBINE_SWITCH,
HO_MC_SIGNAL_IUR_INTRA_SWITCH,
HO_MC_SIGNAL_SWITCH,
HO_MC_SNA_RESTRICTION_SWITCH,
HO_LTE_PS_OUT_SWITCH,
HO_LTE_SERVICE_PS_OUT_SWITCH,
HO_H2G_SRVCC_SWITCH,
HO_INTRA_FREQ_HIGHPRIOR_2D2F_SWITCH,
HO_CIO_1D_USED,
HO_HCS_SPD_INI_BSD_UE_SWITCH,
HO_L2U_EMGCALL_SWITCH,
HO_UMTS_TO_LTE_FAST_RETURN_SWITCH,
HO_HHO_WITH_INTRA_FREQ_MR_SWITCH,
HO_MULTIRAB_CSPS_HO_COV_PARA_SWITCH
Default Value:
HO_ALGO_HCS_SPEED_EST_SWITCH:
0,HO_ALGO_LDR_ALLOW_SHO_SWITCH:
1,HO_ALGO_MBMS_FLC_SWITCH:
0,HO_ALGO_OVERLAY_SWITCH:
0,HO_INTER_FREQ_HARD_HO_SWITCH:
0,HO_LTE_SERVICE_PSHO_OUT_SWITCH:
0,HO_INTER_RAT_CS_OUT_SWITCH:
1,HO_INTER_RAT_PS_3G2G_CELLCHG_NACC_
SWITCH:
0,HO_INTER_RAT_PS_3G2G_RELOCATION_SWI
TCH:0,HO_INTER_RAT_PS_OUT_SWITCH:
1,HO_INTER_RAT_RNC_SERVICE_HO_SWITCH:
0,HO_INTRA_FREQ_DETSET_INTO_ACTSET_S
WITCH:
1,HO_INTRA_FREQ_DETSET_RPRT_SWITCH:
1,HO_INTRA_FREQ_HARD_HO_SWITCH:
1,HO_INTRA_FREQ_RPRT_1J_SWITCH:
0,HO_INTRA_FREQ_SOFT_HO_SWITCH:
1,HO_MC_MEAS_BEYOND_UE_CAP_SWITCH:
HHOTR BSC690 ADD WRFD- Intra Meaning: Indicating whether to trigger hard handover
IG 0 UNRNC 020301 Frequen cross the Iur interface between the RNC and the
MOD WRFD- cy Hard neighboring RNC.
UNRNC 020302 Handov GUI Value Range: OFF, ON
er
WRFD- Unit: None
020304 Inter
Frequen Actual Value Range: OFF, ON
WRFD- cy Hard Default Value: None
040202 Handov
er Based
on
Coverag
e
Inter
Frequen
cy Hard
Handov
er Based
on DL
QoS
RNC
Node
Redunda
ncy
HHOTR BSC691 ADD WRFD- Intra Meaning: Indicating whether to trigger hard handover
IG 0 UNRNC 020301 Frequen cross the Iur interface between the RNC and the
MOD WRFD- cy Hard neighboring RNC.
UNRNC 020302 Handov GUI Value Range: OFF, ON
er
WRFD- Unit: None
020304 Inter
Frequen Actual Value Range: OFF, ON
cy Hard Default Value: None
Handov
er Based
on
Coverag
e
Inter
Frequen
cy Hard
Handov
er Based
on DL
QoS
APFlag BSC690 ADD WRFD- SRNS Meaning: Access point (AP) cell indicator. When the
0 UEXT3 020605 Relocati indicator is "TRUE", it indicates that the cell is an AP
GCELL on cell. AP is a device for accessing the UMTS wireless
MOD Introduc network. This device integrates the functions of the
UEXT3 tion NodeB software and parts of the functions of the RNC
GCELL Package software. It is applied to households and SOHO users.
GUI Value Range: FALSE, TRUE
Unit: None
Actual Value Range: TRUE, FALSE
Default Value: False
APFlag BSC691 ADD WRFD- SRNS Meaning: Access point (AP) cell indicator. When the
0 UEXT3 020605 Relocati indicator is "TRUE", it indicates that the cell is an AP
GCELL on cell. AP is a device for accessing the UMTS wireless
MOD Introduc network. This device integrates the functions of the
UEXT3 tion NodeB software and parts of the functions of the RNC
GCELL Package software. It is applied to households and SOHO users.
GUI Value Range: FALSE, TRUE
Unit: None
Actual Value Range: TRUE, FALSE
Default Value: False
MaxCell BSC690 ADD WRFD- Inter Meaning: Maximum number of cells in an active set.
InActive 0 UCELLI 020203 RNC This parameter is used to achieve the balance between
Set NTRAF WRFD- Soft the signal quality in the SHO area and the system
REQHO 020202 Handov performance. If more cells are in the active set, a user
MOD er can obtain a greater macro diversity gain; the intra-
UCELLI Intra frequency interference is smaller. In this case,
NTRAF RNC however, the user occupies resources of several cells.
REQHO Soft This increases the amount of data to be processed and
Handov lowers the system performance.
er GUI Value Range: 1~6
Unit: None
Actual Value Range: 1~6
Default Value: 3
MaxCell BSC691 ADD WRFD- Inter Meaning: Maximum number of cells in an active set.
InActive 0 UCELLI 020203 RNC This parameter is used to achieve the balance between
Set NTRAF WRFD- Soft the signal quality in the SHO area and the system
REQHO 020202 Handov performance. If more cells are in the active set, a user
MOD er can obtain a greater macro diversity gain; the intra-
UCELLI Intra frequency interference is smaller. In this case,
NTRAF RNC however, the user occupies resources of several cells.
REQHO Soft This increases the amount of data to be processed and
Handov lowers the system performance.
er GUI Value Range: 1~6
Unit: None
Actual Value Range: 1~6
Default Value: 3
CIO BSC690 ADD WRFD- Intra Meaning: Cell individual offset (CIO) of the current
0 UCELL 020201 Node B cell. This parameter works together with "CIOOffset"
SETUP WRFD- Softer for intra-frequency and inter-frequency handover
MOD 020203 Handov decision. The larger the sum of the values of this
UCELL er parameter and "CIOOffset", the higher the probability
WRFD- of handover to the neighboring cell. The smaller the
SETUP 020202 Inter
RNC sum of the values of this parameter and "CIOOffset",
WRFD- Soft the lower the probability of handover to the
020309 Handov neighboring cell. For details about this parameter, see
WRFD- er 3GPP TS 25.331.
020302 Intra GUI Value Range: -20~20
WRFD- RNC Unit: 0.5dB
020303 Soft Actual Value Range: -10~10
WRFD- Handov
er Default Value: 0
020304
WRFD- Inter-
020305 RAT
Handov
er Based
on DL
QoS
Inter
Frequen
cy Hard
Handov
er Based
on
Coverag
e
Inter-
RAT
Handov
er Based
on
Coverag
e
Inter
Frequen
cy Hard
Handov
er Based
on DL
QoS
Inter-
RAT
Handov
er Based
on
Service
CIO BSC691 ADD WRFD- Intra Meaning: Cell individual offset (CIO) of the current
0 UCELL 020201 Node B cell. This parameter works together with "CIOOffset"
SETUP WRFD- Softer for intra-frequency and inter-frequency handover
MOD 020203 Handov decision. The larger the sum of the values of this
UCELL er parameter and "CIOOffset", the higher the probability
WRFD- of handover to the neighboring cell. The smaller the
SETUP 020202 Inter
RNC sum of the values of this parameter and "CIOOffset",
WRFD- the lower the probability of handover to the
Soft
020309 neighboring cell. For details about this parameter, see
Handov
WRFD- er 3GPP TS 25.331.
020302 GUI Value Range: -20~20
Intra
WRFD- RNC Unit: 0.5dB
020303 Soft Actual Value Range: -10~10
WRFD- Handov
Default Value: 0
020304 er
WRFD- Inter-
020305 RAT
Handov
er Based
on DL
QoS
Inter
Frequen
cy Hard
Handov
er Based
on
Coverag
e
Inter-
RAT
Handov
er Based
on
Coverag
e
Inter
Frequen
cy Hard
Handov
er Based
on DL
QoS
Inter-
RAT
Handov
er Based
on
Service
Weight BSC690 ADD WRFD- Inter Meaning: Used for calculating the relative threshold
0 UCELLI 020203 RNC of the soft handover based on the measurement report
NTRAF WRFD- Soft of each cell in the active set. If this parameter is set to
REQHO 020202 Handov a greater value, the relative threshold of the soft
MOD er handover is greater with the other conditions
UCELLI Intra unchanged. For detailed information of this parameter,
NTRAF RNC refer to 3GPP TS 25.133. When this parameter is set
REQHO Soft to 0, the general quality of the active set is the quality
Handov of the best cell. In this case, the relative threshold of
er soft handover depends on the related measurement
values of the best cell in the active set. When this
parameter is set to 1, the relative threshold of the soft
handover depends on the equivalent signal strength
obtained when maximum ratio combining is
performed in the downlink of all cells in the active set.
GUI Value Range: 0~20
Unit: None
Actual Value Range: 0~2, step: 0.1
Default Value: 0
Weight BSC691 ADD WRFD- Inter Meaning: Used for calculating the relative threshold
0 UCELLI 020203 RNC of the soft handover based on the measurement report
NTRAF WRFD- Soft of each cell in the active set. If this parameter is set to
REQHO 020202 Handov a greater value, the relative threshold of the soft
MOD er handover is greater with the other conditions
UCELLI Intra unchanged. For detailed information of this parameter,
NTRAF RNC refer to 3GPP TS 25.133. When this parameter is set
REQHO Soft to 0, the general quality of the active set is the quality
Handov of the best cell. In this case, the relative threshold of
er soft handover depends on the related measurement
values of the best cell in the active set. When this
parameter is set to 1, the relative threshold of the soft
handover depends on the equivalent signal strength
obtained when maximum ratio combining is
performed in the downlink of all cells in the active set.
GUI Value Range: 0~20
Unit: None
Actual Value Range: 0~2, step: 0.1
Default Value: 0
CellsFor BSC690 ADD WRFD- Inter Meaning: Determines whether event 1A threshold is
bidden1 0 UINTR 020203 RNC affected when the cell is added to the active set. If this
A AFREQ WRFD- Soft parameter is set to "NOT_AFFECT", the relative
NCELL 020202 Handov threshold of event 1A is not affected when the cell is
MOD er added to the active set. That is, the cell signals are
UINTR Intra N/A when the UE evaluates whether event 1A should
AFREQ RNC be triggered. If this parameter is set to "AFFECT", the
NCELL Soft relative threshold of event 1A is affected when the cell
Handov is added to the active set. That is, the cell signals are
er involved when the UE evaluates whether event 1A
should be triggered.
GUI Value Range: AFFECT, NOT_AFFECT
Unit: None
Actual Value Range: AFFECT, NOT_AFFECT
Default Value: AFFECT
CellsFor BSC691 ADD WRFD- Inter Meaning: Determines whether event 1A threshold is
bidden1 0 UINTR 020203 RNC affected when the cell is added to the active set. If this
A AFREQ WRFD- Soft parameter is set to "NOT_AFFECT", the relative
NCELL 020202 Handov threshold of event 1A is not affected when the cell is
MOD er added to the active set. That is, the cell signals are
UINTR Intra N/A when the UE evaluates whether event 1A should
AFREQ RNC be triggered. If this parameter is set to "AFFECT", the
NCELL Soft relative threshold of event 1A is affected when the cell
Handov is added to the active set. That is, the cell signals are
er involved when the UE evaluates whether event 1A
should be triggered.
GUI Value Range: AFFECT, NOT_AFFECT
Unit: None
Actual Value Range: AFFECT, NOT_AFFECT
Default Value: AFFECT
HystFor BSC690 ADD WRFD- Inter Meaning: Hysteresis for triggering event 1A. For
1A 0 UCELLI 020203 RNC details, see 3GPP TS 25.331. This parameter can be
NTRAF WRFD- Soft used to reduce ping-pong handovers and unnecessary
REQHO 020202 Handov handovers. When adjusting the setting of this
MOD er parameter, you need to consider the filter coefficient
UCELLI Intra and the interval between detection of event 1A and
NTRAF RNC sending of the measurement report.
REQHO Soft GUI Value Range: 0~15
Handov Unit: 0.5dB
er
Actual Value Range: 0~7.5
Default Value: 0
HystFor BSC691 ADD WRFD- Inter Meaning: Hysteresis for triggering event 1A. For
1A 0 UCELLI 020203 RNC details, see 3GPP TS 25.331. This parameter can be
NTRAF WRFD- Soft used to reduce ping-pong handovers and unnecessary
REQHO 020202 Handov handovers. When adjusting the setting of this
MOD er parameter, you need to consider the filter coefficient
UCELLI Intra and the interval between detection of event 1A and
NTRAF RNC sending of the measurement report.
REQHO Soft GUI Value Range: 0~15
Handov Unit: 0.5dB
er
Actual Value Range: 0~7.5
Default Value: 0
HystFor BSC690 ADD WRFD- Inter Meaning: This parameter specifies the hysteretic value
1B 0 UCELLI 020203 RNC for event 1B. The value of this parameter is associated
NTRAF WRFD- Soft with the slow fading, and it can be used to reduce
REQHO 020202 Handov ping-pong handovers and incorrect handovers. For
MOD er details on the definition of this parameter, see 3GPP
UCELLI Intra TS 25.331.In addition, filter coefficient and interval
NTRAF RNC time must be considered in setting this parameter.
REQHO Soft GUI Value Range: 0~15
Handov Unit: 0.5dB
er
Actual Value Range: 0~7.5
Default Value: 0
HystFor BSC691 ADD WRFD- Inter Meaning: This parameter specifies the hysteretic value
1B 0 UCELLI 020203 RNC for event 1B. The value of this parameter is associated
NTRAF WRFD- Soft with the slow fading, and it can be used to reduce
REQHO 020202 Handov ping-pong handovers and incorrect handovers. For
MOD er details on the definition of this parameter, see 3GPP
UCELLI Intra TS 25.331.In addition, filter coefficient and interval
NTRAF RNC time must be considered in setting this parameter.
REQHO Soft GUI Value Range: 0~15
Handov Unit: 0.5dB
er
Actual Value Range: 0~7.5
Default Value: 0
HystFor BSC690 ADD WRFD- Inter Meaning: This parameter specifies the hysteretic value
1C 0 UCELLI 020203 RNC for event 1C. The value of this parameter is associated
NTRAF WRFD- Soft with the slow fading, and it can be used to reduce
REQHO 020202 Handov ping-pong handovers and incorrect handovers. For
MOD er details on the definition of this parameter, see 3GPP
UCELLI Intra TS 25.331.In addition, filter coefficient and interval
NTRAF RNC time must be considered in setting this parameter.
REQHO Soft GUI Value Range: 0~15
Handov Unit: 0.5dB
er
Actual Value Range: 0~7.5
Default Value: 8
HystFor BSC691 ADD WRFD- Inter Meaning: This parameter specifies the hysteretic value
1C 0 UCELLI 020203 RNC for event 1C. The value of this parameter is associated
NTRAF WRFD- Soft with the slow fading, and it can be used to reduce
REQHO 020202 Handov ping-pong handovers and incorrect handovers. For
MOD er details on the definition of this parameter, see 3GPP
UCELLI Intra TS 25.331.In addition, filter coefficient and interval
NTRAF RNC time must be considered in setting this parameter.
REQHO Soft GUI Value Range: 0~15
Handov Unit: 0.5dB
er
Actual Value Range: 0~7.5
Default Value: 8
HystFor BSC690 ADD WRFD- Inter Meaning: This parameter specifies the hysteretic value
1D 0 UCELLI 020203 RNC for event 1D. The value of this parameter is associated
NTRAF WRFD- Soft with the slow fading, and it can be used to reduce
REQHO 020202 Handov ping-pong handovers and incorrect handovers. For
MOD er details on the definition of this parameter, see 3GPP
UCELLI Intra TS 25.331.In addition, filter coefficient and interval
NTRAF RNC time must be considered in setting this parameter.
REQHO Soft GUI Value Range: 0~15
Handov Unit: 0.5dB
er
Actual Value Range: 0~7.5
Default Value: 8
HystFor BSC691 ADD WRFD- Inter Meaning: This parameter specifies the hysteretic value
1D 0 UCELLI 020203 RNC for event 1D. The value of this parameter is associated
NTRAF WRFD- Soft with the slow fading, and it can be used to reduce
REQHO 020202 Handov ping-pong handovers and incorrect handovers. For
MOD er details on the definition of this parameter, see 3GPP
UCELLI Intra TS 25.331.In addition, filter coefficient and interval
NTRAF RNC time must be considered in setting this parameter.
REQHO Soft GUI Value Range: 0~15
Handov Unit: 0.5dB
er
Actual Value Range: 0~7.5
Default Value: 8
AST_HSDPA_SERV_CELL_CHANGE_SWITCH),
RLRST_ASU_SUCC_COUNTERS_CORRECT_SW
ITCH(RLRST_ASU_SUCC_COUNTERS_CORREC
T_SWITCH),
COUNT_STATE_CHG_BY_RAB_EHN_SWITCH(C
OUNT_STATE_CHG_BY_RAB_EHN_SWITCH),
RAB_RELATED_COUNTER_OPT_SWITCH(RAB_
RELATED_COUNTER_OPT_SWITCH),
CELLUPDATE_PROCEDURE_OPT_SWITCH(CEL
LUPDATE_PROCEDURE_OPT_SWITCH),
PTT_PAGING_PRD_CRRCT_SWITCH(PTT_PAGI
NG_PRD_CRRCT_SWITCH),
RRC_REL_STATUS_RSP_RAB_ASS_REQ_SWITC
H(RRC_REL_STATUS_RSP_RAB_ASS_REQ_SWI
TCH),
L2U_UP_DELAY_OPT_SWITCH(L2U_UP_DELAY
_OPT_SWITCH),
PRI_LDR_SYSHO_OUT_USE_SELECT_OPT_SWI
TCH(PRI_LDR_SYSHO_OUT_USE_SELECT_OPT
_SWITCH)
Unit: None
Actual Value Range:
SYS_RELOC_OUT_SUCC_STAT_OPT_SWITCH,
RL_REEST_PS_ON_FACH_SWITCH,
CELLUPDATE_MEASUREMENT_OPT_SWITCH,
D2F_PROCEDURE_OPTIMIZATION_SWITCH,
F2D_PROCEDURE_OPTIMIZATION_SWITCH,
FOREVER_PCH_CTRL_PLANE_SHARE_OPT,
FOREVER_PCH_USER_PLANE_SHARE_OPT,
RAB_REL_SRV_CELL_CHG_CROSS_SWITCH,
SCRIWITHCAUSE_OVERLAP_SWITCH,
P2F_CUC_REPEAT_SWITCH,
UU_ABN_REL_INFO_NOTIFY_NODEB_SWITCH
,
D2F_AM_PROCEDURE_OPTIMIZATION_SWITC
H,
AM_D2F_F2D_RESTMR_OPTIMIZATION_SWITC
H,
D2P_DT_MSG_BUFFER_SWITCH,
CM_CODE_CONFLICT_OPT_SWITCH,
H_SERV_CELL_CHANGE_MSG_OPT_SWITCH,
FAST_HSDPA_SERV_CELL_CHANGE_SWITCH,
RLRST_ASU_SUCC_COUNTERS_CORRECT_SW
ITCH,
COUNT_STATE_CHG_BY_RAB_EHN_SWITCH,
RAB_RELATED_COUNTER_OPT_SWITCH,
CELLUPDATE_PROCEDURE_OPT_SWITCH,
PTT_PAGING_PRD_CRRCT_SWITCH,
RRC_REL_STATUS_RSP_RAB_ASS_REQ_SWITC
H,
L2U_UP_DELAY_OPT_SWITCH,
PRI_LDR_SYSHO_OUT_USE_SELECT_OPT_SWI
TCH
Default Value:
SYS_RELOC_OUT_SUCC_STAT_OPT_SWITCH:
1,RL_REEST_PS_ON_FACH_SWITCH:
0,CELLUPDATE_MEASUREMENT_OPT_SWITCH
:0,D2F_PROCEDURE_OPTIMIZATION_SWITCH:
0,F2D_PROCEDURE_OPTIMIZATION_SWITCH:
0,FOREVER_PCH_CTRL_PLANE_SHARE_OPT:
0,FOREVER_PCH_USER_PLANE_SHARE_OPT:
0,RAB_REL_SRV_CELL_CHG_CROSS_SWITCH:
0,SCRIWITHCAUSE_OVERLAP_SWITCH:
0,P2F_CUC_REPEAT_SWITCH:
0,UU_ABN_REL_INFO_NOTIFY_NODEB_SWITC
H:
0,D2F_AM_PROCEDURE_OPTIMIZATION_SWIT
CH:
0,AM_D2F_F2D_RESTMR_OPTIMIZATION_SWIT
CH:0,D2P_DT_MSG_BUFFER_SWITCH:
0,CM_CODE_CONFLICT_OPT_SWITCH:
1,H_SERV_CELL_CHANGE_MSG_OPT_SWITCH:
0,FAST_HSDPA_SERV_CELL_CHANGE_SWITCH
:
0,RLRST_ASU_SUCC_COUNTERS_CORRECT_S
WITCH:
0,COUNT_STATE_CHG_BY_RAB_EHN_SWITCH:
0,RAB_RELATED_COUNTER_OPT_SWITCH:
0,CELLUPDATE_PROCEDURE_OPT_SWITCH:
1,PTT_PAGING_PRD_CRRCT_SWITCH:
0,RRC_REL_STATUS_RSP_RAB_ASS_REQ_SWIT
CH:0,L2U_UP_DELAY_OPT_SWITCH:
1,PRI_LDR_SYSHO_OUT_USE_SELECT_OPT_S
WITCH:0
AST_HSDPA_SERV_CELL_CHANGE_SWITCH),
RLRST_ASU_SUCC_COUNTERS_CORRECT_SW
ITCH(RLRST_ASU_SUCC_COUNTERS_CORREC
T_SWITCH),
COUNT_STATE_CHG_BY_RAB_EHN_SWITCH(C
OUNT_STATE_CHG_BY_RAB_EHN_SWITCH),
RAB_RELATED_COUNTER_OPT_SWITCH(RAB_
RELATED_COUNTER_OPT_SWITCH),
CELLUPDATE_PROCEDURE_OPT_SWITCH(CEL
LUPDATE_PROCEDURE_OPT_SWITCH),
PTT_PAGING_PRD_CRRCT_SWITCH(PTT_PAGI
NG_PRD_CRRCT_SWITCH),
RRC_REL_STATUS_RSP_RAB_ASS_REQ_SWITC
H(RRC_REL_STATUS_RSP_RAB_ASS_REQ_SWI
TCH),
L2U_UP_DELAY_OPT_SWITCH(L2U_UP_DELAY
_OPT_SWITCH),
PRI_LDR_SYSHO_OUT_USE_SELECT_OPT_SWI
TCH(PRI_LDR_SYSHO_OUT_USE_SELECT_OPT
_SWITCH)
Unit: None
Actual Value Range:
SYS_RELOC_OUT_SUCC_STAT_OPT_SWITCH,
RL_REEST_PS_ON_FACH_SWITCH,
CELLUPDATE_MEASUREMENT_OPT_SWITCH,
D2F_PROCEDURE_OPTIMIZATION_SWITCH,
F2D_PROCEDURE_OPTIMIZATION_SWITCH,
FOREVER_PCH_CTRL_PLANE_SHARE_OPT,
FOREVER_PCH_USER_PLANE_SHARE_OPT,
RAB_REL_SRV_CELL_CHG_CROSS_SWITCH,
SCRIWITHCAUSE_OVERLAP_SWITCH,
P2F_CUC_REPEAT_SWITCH,
UU_ABN_REL_INFO_NOTIFY_NODEB_SWITCH
,
D2F_AM_PROCEDURE_OPTIMIZATION_SWITC
H,
AM_D2F_F2D_RESTMR_OPTIMIZATION_SWITC
H,
D2P_DT_MSG_BUFFER_SWITCH,
CM_CODE_CONFLICT_OPT_SWITCH,
H_SERV_CELL_CHANGE_MSG_OPT_SWITCH,
FAST_HSDPA_SERV_CELL_CHANGE_SWITCH,
RLRST_ASU_SUCC_COUNTERS_CORRECT_SW
ITCH,
COUNT_STATE_CHG_BY_RAB_EHN_SWITCH,
RAB_RELATED_COUNTER_OPT_SWITCH,
CELLUPDATE_PROCEDURE_OPT_SWITCH,
PTT_PAGING_PRD_CRRCT_SWITCH,
RRC_REL_STATUS_RSP_RAB_ASS_REQ_SWITC
H,
L2U_UP_DELAY_OPT_SWITCH,
PRI_LDR_SYSHO_OUT_USE_SELECT_OPT_SWI
TCH
Default Value:
SYS_RELOC_OUT_SUCC_STAT_OPT_SWITCH:
1,RL_REEST_PS_ON_FACH_SWITCH:
0,CELLUPDATE_MEASUREMENT_OPT_SWITCH
:0,D2F_PROCEDURE_OPTIMIZATION_SWITCH:
0,F2D_PROCEDURE_OPTIMIZATION_SWITCH:
0,FOREVER_PCH_CTRL_PLANE_SHARE_OPT:
0,FOREVER_PCH_USER_PLANE_SHARE_OPT:
0,RAB_REL_SRV_CELL_CHG_CROSS_SWITCH:
0,SCRIWITHCAUSE_OVERLAP_SWITCH:
0,P2F_CUC_REPEAT_SWITCH:
0,UU_ABN_REL_INFO_NOTIFY_NODEB_SWITC
H:
0,D2F_AM_PROCEDURE_OPTIMIZATION_SWIT
CH:
0,AM_D2F_F2D_RESTMR_OPTIMIZATION_SWIT
CH:0,D2P_DT_MSG_BUFFER_SWITCH:
0,CM_CODE_CONFLICT_OPT_SWITCH:
1,H_SERV_CELL_CHANGE_MSG_OPT_SWITCH:
0,FAST_HSDPA_SERV_CELL_CHANGE_SWITCH
:
0,RLRST_ASU_SUCC_COUNTERS_CORRECT_S
WITCH:
0,COUNT_STATE_CHG_BY_RAB_EHN_SWITCH:
0,RAB_RELATED_COUNTER_OPT_SWITCH:
0,CELLUPDATE_PROCEDURE_OPT_SWITCH:
1,PTT_PAGING_PRD_CRRCT_SWITCH:
0,RRC_REL_STATUS_RSP_RAB_ASS_REQ_SWIT
CH:0,L2U_UP_DELAY_OPT_SWITCH:
1,PRI_LDR_SYSHO_OUT_USE_SELECT_OPT_S
WITCH:0
HO_GSMNCELL_OPGRP_CARRY_OVER_IUR_S
WITCH2,
HO_SRVCC_FAST_RETURN_TO_LTE_SWITCH,
HO_CSFB_BASED_MEAS_FAST_RETURN_SWIT
CH,
HO_CSFB_BASED_RSCP_FAST_RETURN_SWIT
CH,
HO_HANDOVER_FAST_RETURN_TO_LTE_SWI
TCH
Unit: None
Actual Value Range:
HO_COMACROMICRO_INTER_FREQ_OUT_SWI
TCH,
HO_U2L_REDIR_BASED_ABSOLUTE_FREQ_SW
ITCH,
HO_U2L_COV_PS_REDIRECT_SWITCH,
HO_U2L_COV_PS_HO_SWITCH,
HO_INTER_RAT_PENALTY_FOR_UNCFG_SWIT
CH,
HO_CS_IRATHHO_WITH_INTRA_FREQ_MR_SW
ITCH,
HO_PS_IRATHHO_WITH_INTRA_FREQ_MR_SW
ITCH,
HO_MC_INTRAFREQ_NCELL_COMBINE_SWIT
CH,
HO_MC_INTERFREQ_NCELL_COMBINE_SWIT
CH,
HO_MC_GSM_NCELL_COMBINE_SWITCH,
HO_MC_LTE_NCELL_COMBINE_SWITCH,
HO_U2L_LOAD_PS_HO_SWITCH,
HO_U2L_LOAD_PS_REDIRECT_SWITCH,
HO_INTRA_FREQ_DETSET_INTO_ACTSET_OPT
SWH,
HO_INTRA_DETSET_DRNC_CELL_INTO_ACTS
ET,
HO_1A_OR_1C_TRIG_SERV_CELL_CHG_SWITC
H,
HO_1D_TRIG_SERV_CELL_CHG_JUDGE_SWITC
H, HO_SPID_MM_SWITCH,
HO_SRV_CELL_CHG_1D_RSCP_SWITCH,
HO_IUR_U2L_REDIR_SWITCH,
HO_IUR_U2L_FAST_RETURN_SWITCH,
HO_LTE_SERVICE_NEED_RSCP_SWITCH,
HO_GSMNCELL_OPGRP_CARRY_OVER_IUR_S
WITCH,
HO_INTER_RAT_DRNC_GSMNCELL_FILTER_S
WITCH,
HO_MC_INTRAFREQ_1A_REPLACE_1C_SWITC
H, HO_U2L_CONN_PRIO_SWITCH,
HO_GSMNCELL_OPGRP_CARRY_OVER_IUR_S
WITCH2,
HO_SRVCC_FAST_RETURN_TO_LTE_SWITCH,
HO_CSFB_BASED_MEAS_FAST_RETURN_SWIT
CH,
HO_CSFB_BASED_RSCP_FAST_RETURN_SWIT
CH,
HO_HANDOVER_FAST_RETURN_TO_LTE_SWI
TCH
Default Value:
HO_COMACROMICRO_INTER_FREQ_OUT_SWI
TCH:
0,HO_U2L_REDIR_BASED_ABSOLUTE_FREQ_S
WITCH:
0,HO_U2L_COV_PS_REDIRECT_SWITCH:
0,HO_U2L_COV_PS_HO_SWITCH:
0,HO_INTER_RAT_PENALTY_FOR_UNCFG_SWI
TCH:
0,HO_CS_IRATHHO_WITH_INTRA_FREQ_MR_S
WITCH:
0,HO_PS_IRATHHO_WITH_INTRA_FREQ_MR_S
WITCH:
0,HO_MC_INTRAFREQ_NCELL_COMBINE_SWI
TCH:
1,HO_MC_INTERFREQ_NCELL_COMBINE_SWI
TCH:
1,HO_MC_GSM_NCELL_COMBINE_SWITCH:
1,HO_MC_LTE_NCELL_COMBINE_SWITCH:
1,HO_U2L_LOAD_PS_HO_SWITCH:
0,HO_U2L_LOAD_PS_REDIRECT_SWITCH:
0,HO_INTRA_FREQ_DETSET_INTO_ACTSET_O
PTSWH:
0,HO_INTRA_DETSET_DRNC_CELL_INTO_ACT
SET:
0,HO_1A_OR_1C_TRIG_SERV_CELL_CHG_SWIT
CH:
0,HO_1D_TRIG_SERV_CELL_CHG_JUDGE_SWI
TCH:0,HO_SPID_MM_SWITCH:
0,HO_SRV_CELL_CHG_1D_RSCP_SWITCH:
0,HO_IUR_U2L_REDIR_SWITCH:
1,HO_IUR_U2L_FAST_RETURN_SWITCH:
0,HO_LTE_SERVICE_NEED_RSCP_SWITCH:
0,HO_GSMNCELL_OPGRP_CARRY_OVER_IUR_
SWITCH:
HO_GSMNCELL_OPGRP_CARRY_OVER_IUR_S
WITCH2,
HO_SRVCC_FAST_RETURN_TO_LTE_SWITCH,
HO_CSFB_BASED_MEAS_FAST_RETURN_SWIT
CH,
HO_CSFB_BASED_RSCP_FAST_RETURN_SWIT
CH,
HO_HANDOVER_FAST_RETURN_TO_LTE_SWI
TCH
Unit: None
Actual Value Range:
HO_COMACROMICRO_INTER_FREQ_OUT_SWI
TCH,
HO_U2L_REDIR_BASED_ABSOLUTE_FREQ_SW
ITCH,
HO_U2L_COV_PS_REDIRECT_SWITCH,
HO_U2L_COV_PS_HO_SWITCH,
HO_INTER_RAT_PENALTY_FOR_UNCFG_SWIT
CH,
HO_CS_IRATHHO_WITH_INTRA_FREQ_MR_SW
ITCH,
HO_PS_IRATHHO_WITH_INTRA_FREQ_MR_SW
ITCH,
HO_MC_INTRAFREQ_NCELL_COMBINE_SWIT
CH,
HO_MC_INTERFREQ_NCELL_COMBINE_SWIT
CH,
HO_MC_GSM_NCELL_COMBINE_SWITCH,
HO_MC_LTE_NCELL_COMBINE_SWITCH,
HO_U2L_LOAD_PS_HO_SWITCH,
HO_U2L_LOAD_PS_REDIRECT_SWITCH,
HO_INTRA_FREQ_DETSET_INTO_ACTSET_OPT
SWH,
HO_INTRA_DETSET_DRNC_CELL_INTO_ACTS
ET,
HO_1A_OR_1C_TRIG_SERV_CELL_CHG_SWITC
H,
HO_1D_TRIG_SERV_CELL_CHG_JUDGE_SWITC
H, HO_SPID_MM_SWITCH,
HO_SRV_CELL_CHG_1D_RSCP_SWITCH,
HO_IUR_U2L_REDIR_SWITCH,
HO_IUR_U2L_FAST_RETURN_SWITCH,
HO_LTE_SERVICE_NEED_RSCP_SWITCH,
HO_GSMNCELL_OPGRP_CARRY_OVER_IUR_S
WITCH,
HO_INTER_RAT_DRNC_GSMNCELL_FILTER_S
WITCH,
HO_MC_INTRAFREQ_1A_REPLACE_1C_SWITC
H, HO_U2L_CONN_PRIO_SWITCH,
HO_GSMNCELL_OPGRP_CARRY_OVER_IUR_S
WITCH2,
HO_SRVCC_FAST_RETURN_TO_LTE_SWITCH,
HO_CSFB_BASED_MEAS_FAST_RETURN_SWIT
CH,
HO_CSFB_BASED_RSCP_FAST_RETURN_SWIT
CH,
HO_HANDOVER_FAST_RETURN_TO_LTE_SWI
TCH
Default Value:
HO_COMACROMICRO_INTER_FREQ_OUT_SWI
TCH:
0,HO_U2L_REDIR_BASED_ABSOLUTE_FREQ_S
WITCH:
0,HO_U2L_COV_PS_REDIRECT_SWITCH:
0,HO_U2L_COV_PS_HO_SWITCH:
0,HO_INTER_RAT_PENALTY_FOR_UNCFG_SWI
TCH:
0,HO_CS_IRATHHO_WITH_INTRA_FREQ_MR_S
WITCH:
0,HO_PS_IRATHHO_WITH_INTRA_FREQ_MR_S
WITCH:
0,HO_MC_INTRAFREQ_NCELL_COMBINE_SWI
TCH:
1,HO_MC_INTERFREQ_NCELL_COMBINE_SWI
TCH:
1,HO_MC_GSM_NCELL_COMBINE_SWITCH:
1,HO_MC_LTE_NCELL_COMBINE_SWITCH:
1,HO_U2L_LOAD_PS_HO_SWITCH:
0,HO_U2L_LOAD_PS_REDIRECT_SWITCH:
0,HO_INTRA_FREQ_DETSET_INTO_ACTSET_O
PTSWH:
0,HO_INTRA_DETSET_DRNC_CELL_INTO_ACT
SET:
0,HO_1A_OR_1C_TRIG_SERV_CELL_CHG_SWIT
CH:
0,HO_1D_TRIG_SERV_CELL_CHG_JUDGE_SWI
TCH:0,HO_SPID_MM_SWITCH:
0,HO_SRV_CELL_CHG_1D_RSCP_SWITCH:
0,HO_IUR_U2L_REDIR_SWITCH:
1,HO_IUR_U2L_FAST_RETURN_SWITCH:
0,HO_LTE_SERVICE_NEED_RSCP_SWITCH:
0,HO_GSMNCELL_OPGRP_CARRY_OVER_IUR_
SWITCH:
HystFor BSC690 SET WRFD- Inter Meaning: This parameter specifies the hysteretic value
1C 0 UINTR 020203 RNC for event 1C. The value of this parameter is associated
AFREQ WRFD- Soft with the slow fading, and it can be used to reduce
HO 020202 Handov ping-pong handovers and incorrect handovers. For
er details on the definition of this parameter, see 3GPP
Intra TS 25.331.In addition, filter coefficient and interval
RNC time must be considered in setting this parameter.
Soft GUI Value Range: 0~15
Handov Unit: 0.5dB
er
Actual Value Range: 0~7.5
Default Value: 8
HystFor BSC691 SET WRFD- Inter Meaning: This parameter specifies the hysteretic value
1C 0 UINTR 020203 RNC for event 1C. The value of this parameter is associated
AFREQ WRFD- Soft with the slow fading, and it can be used to reduce
HO 020202 Handov ping-pong handovers and incorrect handovers. For
er details on the definition of this parameter, see 3GPP
Intra TS 25.331.In addition, filter coefficient and interval
RNC time must be considered in setting this parameter.
Soft GUI Value Range: 0~15
Handov Unit: 0.5dB
er
Actual Value Range: 0~7.5
Default Value: 8
ShoFail BSC690 SET WRFD- Inter Meaning: Maximum allowed number of soft handover
NumFor 0 UINTR 020203 RNC failures. This parameter specifies the maximum
DwnGrd AFREQ WRFD- Soft number of event reporting from the cell that fails to be
HO 020202 Handov added to the active set for soft handovers. If the
er parameter value is reached, rate reduction of the active
Intra set will be triggered and the cell will attempt to join
RNC the active set again. This parameter needs to be
Soft considered in combination with the settings of rate
Handov reduction evaluation period("ShoFailPeriod") and the
er reporting intervals of events 1A and
1C("ReportIntervalfor1A" and
"ReportIntervalfor1C"). Otherwise, the number of
reports cannot reach the required value to trigger rate
reduction during the rate reduction evaluation period
for soft handovers. If this parameter is set to 0, rate
reduction after soft handover failure is disabled.
GUI Value Range: 0~63
Unit: None
Actual Value Range: 0~63
Default Value: 3
ShoFail BSC691 SET WRFD- Inter Meaning: Maximum allowed number of soft handover
NumFor 0 UINTR 020203 RNC failures. This parameter specifies the maximum
DwnGrd AFREQ WRFD- Soft number of event reporting from the cell that fails to be
HO 020202 Handov added to the active set for soft handovers. If the
er parameter value is reached, rate reduction of the active
Intra set will be triggered and the cell will attempt to join
RNC the active set again. This parameter needs to be
Soft considered in combination with the settings of rate
Handov reduction evaluation period("ShoFailPeriod") and the
er reporting intervals of events 1A and
1C("ReportIntervalfor1A" and
"ReportIntervalfor1C"). Otherwise, the number of
reports cannot reach the required value to trigger rate
reduction during the rate reduction evaluation period
for soft handovers. If this parameter is set to 0, rate
reduction after soft handover failure is disabled.
GUI Value Range: 0~63
Unit: None
Actual Value Range: 0~63
Default Value: 3
ShoFail BSC690 SET WRFD- Inter Meaning: Maximum evaluation period for rate
Period 0 UINTR 020203 RNC reduction after soft handover failure. When rate
AFREQ WRFD- Soft reduction evaluation is performed on a cell that fails to
HO 020202 Handov join the active set, the evaluation timer is started. If
er the cell cannot fulfill the criteria for rate reduction
Intra before the timer expires, the cell will not be evaluated
RNC and rate reduction re-attempt will not be initiated.
Soft GUI Value Range: 0~120
Handov Unit: s
er
Actual Value Range: 0~120
Default Value: 60
ShoFail BSC691 SET WRFD- Inter Meaning: Maximum evaluation period for rate
Period 0 UINTR 020203 RNC reduction after soft handover failure. When rate
AFREQ WRFD- Soft reduction evaluation is performed on a cell that fails to
HO 020202 Handov join the active set, the evaluation timer is started. If
er the cell cannot fulfill the criteria for rate reduction
Intra before the timer expires, the cell will not be evaluated
RNC and rate reduction re-attempt will not be initiated.
Soft GUI Value Range: 0~120
Handov Unit: s
er
Actual Value Range: 0~120
Default Value: 60
SoftFail BSC690 SET WRFD- Intra Meaning: Whether to trigger state transitions from
D2FSwi 0 UINTR 020202 RNC CELL_DCH to CELL_FACH (D2F for short) if soft
tch AFREQ Soft handover-based service admission fails. When this
HO Handov parameter is set to ON, failures in soft handover-based
er service admission trigger D2F transitions for R99 non-
real-time PS services if the signal quality of the target
cell is greater than the sum of the signal quality of the
best cell plus the "SoftFailD2FOffset" parameter
value. When this parameter is set to OFF, D2F
transitions are not triggered.
GUI Value Range: OFF, ON
Unit: None
Actual Value Range: OFF, ON
Default Value: OFF
SoftFail BSC691 SET WRFD- Intra Meaning: Whether to trigger state transitions from
D2FSwi 0 UINTR 020202 RNC CELL_DCH to CELL_FACH (D2F for short) if soft
tch AFREQ Soft handover-based service admission fails. When this
HO Handov parameter is set to ON, failures in soft handover-based
er service admission trigger D2F transitions for R99 non-
real-time PS services if the signal quality of the target
cell is greater than the sum of the signal quality of the
best cell plus the "SoftFailD2FOffset" parameter
value. When this parameter is set to OFF, D2F
transitions are not triggered.
GUI Value Range: OFF, ON
Unit: None
Actual Value Range: OFF, ON
Default Value: OFF
SoftFail BSC690 SET WRFD- Intra Meaning: Signal quality offset of the target cell
D2FOffs 0 UINTR 020202 RNC relative to the best cell when a D2F transition is
et AFREQ Soft triggered due to a failure in soft handover-based
HO Handov service admission. Only when the signal quality of the
er target cell is greater than the sum of the signal quality
of the best cell plus this parameter value, a D2F
transition can be triggered if soft handover-based
service admission fails.
GUI Value Range: -29~29
Unit: 0.5dB
Actual Value Range: -14.5~14.5
Default Value: 4
SoftFail BSC691 SET WRFD- Intra Meaning: Signal quality offset of the target cell
D2FOffs 0 UINTR 020202 RNC relative to the best cell when a D2F transition is
et AFREQ Soft triggered due to a failure in soft handover-based
HO Handov service admission. Only when the signal quality of the
er target cell is greater than the sum of the signal quality
of the best cell plus this parameter value, a D2F
transition can be triggered if soft handover-based
service admission fails.
GUI Value Range: -29~29
Unit: 0.5dB
Actual Value Range: -14.5~14.5
Default Value: 4
SoftFail BSC690 SET WRFD- Intra Meaning: Timer during which F2D transitions are
F2DPun 0 UINTR 020202 RNC forbidden after a D2F transition is triggered due to a
ishTime AFREQ Soft failure in soft handover-based service admission.
r HO Handov GUI Value Range: 0~512
er
Unit: s
Actual Value Range: 0~512
Default Value: 10
SoftFail BSC691 SET WRFD- Intra Meaning: Timer during which F2D transitions are
F2DPun 0 UINTR 020202 RNC forbidden after a D2F transition is triggered due to a
ishTime AFREQ Soft failure in soft handover-based service admission.
r HO Handov GUI Value Range: 0~512
er
Unit: s
Actual Value Range: 0~512
Default Value: 10
SoftFail BSC690 SET WRFD- Intra Meaning: Whether to allow for channel switching
E2DSwi 0 UINTR 020202 RNC from the E-DCH to the DCH (E2D for short) after an
tch AFREQ Soft HSUPA UE experiences a soft handover failure. If this
HO Handov parameter is set to ON, E2D is allowed when a soft
er handover fails due to uplink admission failures.
Otherwise, E2D is not allowed when a soft handover
fails.
GUI Value Range: OFF, ON
Unit: None
Actual Value Range: OFF, ON
Default Value: OFF
SoftFail BSC691 SET WRFD- Intra Meaning: Whether to allow for channel switching
E2DSwi 0 UINTR 020202 RNC from the E-DCH to the DCH (E2D for short) after an
tch AFREQ Soft HSUPA UE experiences a soft handover failure. If this
HO Handov parameter is set to ON, E2D is allowed when a soft
er handover fails due to uplink admission failures.
Otherwise, E2D is not allowed when a soft handover
fails.
GUI Value Range: OFF, ON
Unit: None
Actual Value Range: OFF, ON
Default Value: OFF
15.
DRA_THROUGHPUT_BE_STATE_TRANS_SWIT
CH: Whether the throughput measurement-based state
transition algorithm for UEs in the CELL_DCH state
with BE services takes effect.
1: This switch is turned on and the algorithm
triggering throughput measurement-based state
transitions on UEs with BE services from
CELL_DCH to CELL_FACH, CELL_PCH, or
URA_PCH takes effect.
0: This switch is turned off and this algorithm does
not take effect.
16. DRA_THROUGHPUT_BE_D2F_SWITCH:
Whether UEs with BE services in the CELL_DCH
state are preferentially transitioned to the
CELL_FACH state based on the throughput
measurement.
1: This switch is turned on and the throughput
measurement-based state transition algorithm
preferentially triggers D2F state transitions on UEs
with BE services.
0: This switch is turned off and the throughput
measurement-based state transition algorithm
preferentially triggers D2P state transitions on UEs
with BE services.
17.
DRA_BASE_CALL_REESTABLISH_SRB_H2D_S
WITCH: Whether the downlink SRBs of SRB over
HSDPA UEs fall back to the DCH when these UEs
trigger radio link reestablishments. When this switch
is turned on, the RNC first switches downlink SRBs
of SRB over HSDPA UEs to the DCH when sending
the Cell Update Confirm message and then performs
radio link reestablishments if these UEs have triggered
radio link reestablishments. When this switch is
turned off, the downlink SRBs of SRB over HSDPA
UEs remain on the HSDPA channel if these UEs have
triggered radio link reestablishments.
18.
DRA_RRC_FACH_NODEB_UNAVAILABLE_SWI
TCH: Whether to set up RRC connections on the
FACH when NodeB resources become unavailable.
When this switch is set to off, RRC connections are
not set up on the FACH when NodeB resources
become unavailable. When this switch is set to on,
RRC connections are set up on the FACH when
NodeB resources become unavailable.
19. DRA_BE_LITTLE_RATE_THD_SWITCH:
Whether the low activity bit rate threshold is
adaptively adjusted based on the cell status. When this
switch is turned on and the cell is congested, the low
activity bit rate threshold specified by
[UDCCC:LittleRateThd] is considered D0. If the cell
is not congested, the adaptive adjustment function
does not take effect. When this switch is turned off,
the adaptive adjustment function does not take effect.
20.
DRA_BE_INIT_BIT_RATE_TYPE_CSPS_SWITCH
: Whether the bearer channel type and initial access
rate of PS BE services are adaptively adjusted based
on the cell status during the setup of CS+PS BE
combined services. When this switch is turned on and
the cell is congested, the initial access rate type of CS
+PS BE combined services specified by
[UFRC:BeInitBitrateTypeforCsPs] is considered
DCH0K during the setup of CS+PS BE combined
services. If the cell is not congested, the adaptive
adjustment function does not take effect. When this
switch is turned off, the adaptive adjustment function
does not take effect.
21.
DRA_SRB_HRETRY_AFTER_RB_RFG_DRD_SWI
TCH: Whether the RNC triggers channel
reconfiguration for the SRBs to switch from the DCH
to an HSPA channel immediately when the type of a
channel for carrying SRBs during an RB
reconfiguration DRD procedure is limited.
1: This switch is turned on. the RNC triggers channel
reconfiguration for the SRBs to switch from the DCH
to an HSPA channel immediately after the DRD
procedure.
0: This switch is turned off. Channel reconfiguration
is not triggered and the SRBs are carried over the
DCH.
22.DRA_PCH_L2_MC_REL_SWITCH: Whether
Layer 2 measurement control is released after a
D2P/F2P state transition. When this switch is turned
on, all the Layer 2 measurement control messages are
released if the Layer 2 entity is not released after a
D2P/F2P state transition. When this switch is turned
off, all the Layer 2 measurement control messages are
not released if the Layer 2 entity is not released after a
D2P/F2P state transition.
23. DRA_BASE_COVER_UlR99_CQIPO_SWITCH:
Whether to start the coverage-based CQI PO
adjustment function.
When this switch is turned on, the CQI PO is re-
adjusted for those users who are in weak coverage
area and whose uplink is carried over R99 channels
with PS BE services carried over HSDPA and who are
enabled with features involving DC/3C/4C/DB/
MIMO.
When this switch is turned off, the coverage-based
CQI PO adjustment function does not take effect.
Criterion for weak coverage: If RSCP is reported and
the reported RSCP is less than or eaqual to the value
of RscpThdForR99CqiPo, the coverage is considered
weak. If RSCP is not reported, Ec/N0 is used for
coverage decision.
If Ec/N0 is less than or equal to the value of
EcN0ThdForR99CqiPo, the coverage is considered
weak. If neither RSCP nor Ec/N0 is reported, the
coverage is not weak.
The function provided by this parameter is unavailable
in the current version.
GUI Value Range:
DRA_BASE_COVER_BE_E2D_INITSEL_OPT_SW
ITCH,
DRA_PCPICH_ECN0_ON_RACH_UPDATE_SWIT
CH,
DRA_BASE_COVER_BE_E2D_INITSEL_SWITCH
, DRA_BASE_COVER_BE_E2D_SWITCH,
DRA_D2F_OVER_IUR_SWITCH,
DRA_CSPS_0K_RATE_UP_SWITCH,
DRA_CSPS_BOTH_ULDL_RATE_UP_SWITCH,
DRA_PS_STATE_TRANS_WHEN_CS_REL_SWIT
CH, DRA_BASE_COVER_E2D_DCCC_SWITCH,
DRA_WEB_FACH_DELAY_OPT_SWITCH,
DRA_D2F_LIMIT_WITH_CS_IU_CON_SWITCH,
DRA_D2P_WHEN_PS_INACT_SWITCH,
DRA_INTELL_STATE_TRANS_ON_LOAD_SWIT
CH,
DRA_BASE_COVER_LOAD_SRB_H2D_SWITCH,
DRA_THROUGHPUT_BE_STATE_TRANS_SWIT
CH, DRA_THROUGHPUT_BE_D2F_SWITCH,
DRA_BASE_CALL_REESTABLISH_SRB_H2D_S
WITCH,
DRA_RRC_FACH_NODEB_UNAVAILABLE_SWI
TCH, DRA_BE_LITTLE_RATE_THD_SWITCH,
DRA_BE_INIT_BIT_RATE_TYPE_CSPS_SWITCH,
DRA_SRB_HRETRY_AFTER_RB_RFG_DRD_SWI
TCH, DRA_PCH_L2_MC_REL_SWITCH,
DRA_BASE_COVER_UlR99_CQIPO_SWITCH
Unit: None
Actual Value Range:
DRA_BASE_COVER_BE_E2D_INITSEL_OPT_SW
ITCH,
DRA_PCPICH_ECN0_ON_RACH_UPDATE_SWIT
CH,
DRA_BASE_COVER_BE_E2D_INITSEL_SWITCH
,
DRA_BASE_COVER_BE_E2D_SWITCH,
DRA_D2F_OVER_IUR_SWITCH,
DRA_CSPS_0K_RATE_UP_SWITCH,
DRA_CSPS_BOTH_ULDL_RATE_UP_SWITCH,
DRA_PS_STATE_TRANS_WHEN_CS_REL_SWIT
CH,
DRA_BASE_COVER_E2D_DCCC_SWITCH,
DRA_WEB_FACH_DELAY_OPT_SWITCH,
DRA_D2F_LIMIT_WITH_CS_IU_CON_SWITCH,
DRA_D2P_WHEN_PS_INACT_SWITCH,
DRA_INTELL_STATE_TRANS_ON_LOAD_SWIT
CH,
DRA_BASE_COVER_LOAD_SRB_H2D_SWITCH,
DRA_THROUGHPUT_BE_STATE_TRANS_SWIT
CH,
DRA_THROUGHPUT_BE_D2F_SWITCH,
DRA_BASE_CALL_REESTABLISH_SRB_H2D_S
WITCH,
DRA_RRC_FACH_NODEB_UNAVAILABLE_SWI
TCH,
DRA_BE_LITTLE_RATE_THD_SWITCH,
DRA_BE_INIT_BIT_RATE_TYPE_CSPS_SWITCH,
DRA_SRB_HRETRY_AFTER_RB_RFG_DRD_SWI
TCH,
DRA_PCH_L2_MC_REL_SWITCH,
DRA_BASE_COVER_UlR99_CQIPO_SWITCH
Default Value:
DRA_BASE_COVER_BE_E2D_INITSEL_OPT_SW
ITCH:0,
DRA_PCPICH_ECN0_ON_RACH_UPDATE_SWIT
15.
DRA_THROUGHPUT_BE_STATE_TRANS_SWIT
CH: Whether the throughput measurement-based state
transition algorithm for UEs in the CELL_DCH state
with BE services takes effect.
1: This switch is turned on and the algorithm
triggering throughput measurement-based state
transitions on UEs with BE services from
CELL_DCH to CELL_FACH, CELL_PCH, or
URA_PCH takes effect.
0: This switch is turned off and this algorithm does
not take effect.
16. DRA_THROUGHPUT_BE_D2F_SWITCH:
Whether UEs with BE services in the CELL_DCH
state are preferentially transitioned to the
CELL_FACH state based on the throughput
measurement.
1: This switch is turned on and the throughput
measurement-based state transition algorithm
preferentially triggers D2F state transitions on UEs
with BE services.
0: This switch is turned off and the throughput
measurement-based state transition algorithm
preferentially triggers D2P state transitions on UEs
with BE services.
17.
DRA_BASE_CALL_REESTABLISH_SRB_H2D_S
WITCH: Whether the downlink SRBs of SRB over
HSDPA UEs fall back to the DCH when these UEs
trigger radio link reestablishments. When this switch
is turned on, the RNC first switches downlink SRBs
of SRB over HSDPA UEs to the DCH when sending
the Cell Update Confirm message and then performs
radio link reestablishments if these UEs have triggered
radio link reestablishments. When this switch is
turned off, the downlink SRBs of SRB over HSDPA
UEs remain on the HSDPA channel if these UEs have
triggered radio link reestablishments.
18.
DRA_RRC_FACH_NODEB_UNAVAILABLE_SWI
TCH: Whether to set up RRC connections on the
FACH when NodeB resources become unavailable.
When this switch is set to off, RRC connections are
not set up on the FACH when NodeB resources
become unavailable. When this switch is set to on,
RRC connections are set up on the FACH when
NodeB resources become unavailable.
19. DRA_BE_LITTLE_RATE_THD_SWITCH:
Whether the low activity bit rate threshold is
adaptively adjusted based on the cell status. When this
switch is turned on and the cell is congested, the low
activity bit rate threshold specified by
[UDCCC:LittleRateThd] is considered D0. If the cell
is not congested, the adaptive adjustment function
does not take effect. When this switch is turned off,
the adaptive adjustment function does not take effect.
20.
DRA_BE_INIT_BIT_RATE_TYPE_CSPS_SWITCH
: Whether the bearer channel type and initial access
rate of PS BE services are adaptively adjusted based
on the cell status during the setup of CS+PS BE
combined services. When this switch is turned on and
the cell is congested, the initial access rate type of CS
+PS BE combined services specified by
[UFRC:BeInitBitrateTypeforCsPs] is considered
DCH0K during the setup of CS+PS BE combined
services. If the cell is not congested, the adaptive
adjustment function does not take effect. When this
switch is turned off, the adaptive adjustment function
does not take effect.
21.
DRA_SRB_HRETRY_AFTER_RB_RFG_DRD_SWI
TCH: Whether the RNC triggers channel
reconfiguration for the SRBs to switch from the DCH
to an HSPA channel immediately when the type of a
channel for carrying SRBs during an RB
reconfiguration DRD procedure is limited.
1: This switch is turned on. the RNC triggers channel
reconfiguration for the SRBs to switch from the DCH
to an HSPA channel immediately after the DRD
procedure.
0: This switch is turned off. Channel reconfiguration
is not triggered and the SRBs are carried over the
DCH.
22.DRA_PCH_L2_MC_REL_SWITCH: Whether
Layer 2 measurement control is released after a
D2P/F2P state transition. When this switch is turned
on, all the Layer 2 measurement control messages are
released if the Layer 2 entity is not released after a
D2P/F2P state transition. When this switch is turned
off, all the Layer 2 measurement control messages are
not released if the Layer 2 entity is not released after a
D2P/F2P state transition.
23. DRA_BASE_COVER_UlR99_CQIPO_SWITCH:
Whether to start the coverage-based CQI PO
adjustment function.
When this switch is turned on, the CQI PO is re-
adjusted for those users who are in weak coverage
area and whose uplink is carried over R99 channels
with PS BE services carried over HSDPA and who are
enabled with features involving DC/3C/4C/DB/
MIMO.
When this switch is turned off, the coverage-based
CQI PO adjustment function does not take effect.
Criterion for weak coverage: If RSCP is reported and
the reported RSCP is less than or eaqual to the value
of RscpThdForR99CqiPo, the coverage is considered
weak. If RSCP is not reported, Ec/N0 is used for
coverage decision.
If Ec/N0 is less than or equal to the value of
EcN0ThdForR99CqiPo, the coverage is considered
weak. If neither RSCP nor Ec/N0 is reported, the
coverage is not weak.
The function provided by this parameter is unavailable
in the current version.
GUI Value Range:
DRA_BASE_COVER_BE_E2D_INITSEL_OPT_SW
ITCH,
DRA_PCPICH_ECN0_ON_RACH_UPDATE_SWIT
CH,
DRA_BASE_COVER_BE_E2D_INITSEL_SWITCH
, DRA_BASE_COVER_BE_E2D_SWITCH,
DRA_D2F_OVER_IUR_SWITCH,
DRA_CSPS_0K_RATE_UP_SWITCH,
DRA_CSPS_BOTH_ULDL_RATE_UP_SWITCH,
DRA_PS_STATE_TRANS_WHEN_CS_REL_SWIT
CH, DRA_BASE_COVER_E2D_DCCC_SWITCH,
DRA_WEB_FACH_DELAY_OPT_SWITCH,
DRA_D2F_LIMIT_WITH_CS_IU_CON_SWITCH,
DRA_D2P_WHEN_PS_INACT_SWITCH,
DRA_INTELL_STATE_TRANS_ON_LOAD_SWIT
CH,
DRA_BASE_COVER_LOAD_SRB_H2D_SWITCH,
DRA_THROUGHPUT_BE_STATE_TRANS_SWIT
CH, DRA_THROUGHPUT_BE_D2F_SWITCH,
DRA_BASE_CALL_REESTABLISH_SRB_H2D_S
WITCH,
DRA_RRC_FACH_NODEB_UNAVAILABLE_SWI
TCH, DRA_BE_LITTLE_RATE_THD_SWITCH,
DRA_BE_INIT_BIT_RATE_TYPE_CSPS_SWITCH,
DRA_SRB_HRETRY_AFTER_RB_RFG_DRD_SWI
TCH, DRA_PCH_L2_MC_REL_SWITCH,
DRA_BASE_COVER_UlR99_CQIPO_SWITCH
Unit: None
Actual Value Range:
DRA_BASE_COVER_BE_E2D_INITSEL_OPT_SW
ITCH,
DRA_PCPICH_ECN0_ON_RACH_UPDATE_SWIT
CH,
DRA_BASE_COVER_BE_E2D_INITSEL_SWITCH
,
DRA_BASE_COVER_BE_E2D_SWITCH,
DRA_D2F_OVER_IUR_SWITCH,
DRA_CSPS_0K_RATE_UP_SWITCH,
DRA_CSPS_BOTH_ULDL_RATE_UP_SWITCH,
DRA_PS_STATE_TRANS_WHEN_CS_REL_SWIT
CH,
DRA_BASE_COVER_E2D_DCCC_SWITCH,
DRA_WEB_FACH_DELAY_OPT_SWITCH,
DRA_D2F_LIMIT_WITH_CS_IU_CON_SWITCH,
DRA_D2P_WHEN_PS_INACT_SWITCH,
DRA_INTELL_STATE_TRANS_ON_LOAD_SWIT
CH,
DRA_BASE_COVER_LOAD_SRB_H2D_SWITCH,
DRA_THROUGHPUT_BE_STATE_TRANS_SWIT
CH,
DRA_THROUGHPUT_BE_D2F_SWITCH,
DRA_BASE_CALL_REESTABLISH_SRB_H2D_S
WITCH,
DRA_RRC_FACH_NODEB_UNAVAILABLE_SWI
TCH,
DRA_BE_LITTLE_RATE_THD_SWITCH,
DRA_BE_INIT_BIT_RATE_TYPE_CSPS_SWITCH,
DRA_SRB_HRETRY_AFTER_RB_RFG_DRD_SWI
TCH,
DRA_PCH_L2_MC_REL_SWITCH,
DRA_BASE_COVER_UlR99_CQIPO_SWITCH
Default Value:
DRA_BASE_COVER_BE_E2D_INITSEL_OPT_SW
ITCH:0,
DRA_PCPICH_ECN0_ON_RACH_UPDATE_SWIT
RrcRscp BSC690 SET WRFD- TTI Meaning: Interval for UEs to report the RSCP during
PeriodTi 0 UCHLQ 010690 Switch the interval between RRC connection setup and RAB
mer UALIT for BE assignment
YEVAL Services GUI Value Range: D250, D500, D1000, D2000,
UATE Based D3000, D4000, D6000, D8000, D12000, D16000,
on D20000, D24000, D28000, D32000, D64000
Coverag
e Unit: ms
Actual Value Range: 250, 500, 1000, 2000, 3000,
4000, 6000, 8000, 12000, 16000, 20000, 24000,
28000, 32000, 64000
Default Value: D500
RrcRscp BSC691 SET WRFD- TTI Meaning: Interval for UEs to report the RSCP during
PeriodTi 0 UCHLQ 010690 Switch the interval between RRC connection setup and RAB
mer UALIT for BE assignment
YEVAL Services GUI Value Range: D250, D500, D1000, D2000,
UATE Based D3000, D4000, D6000, D8000, D12000, D16000,
on D20000, D24000, D28000, D32000, D64000
Coverag
e Unit: ms
Actual Value Range: 250, 500, 1000, 2000, 3000,
4000, 6000, 8000, 12000, 16000, 20000, 24000,
28000, 32000, 64000
Default Value: D500
SrbH2D BSC690 SET WRFD- SRB Meaning: Measurement period of RSCP and Ec/N0
RabRsc 0 UCHLQ 010652 over for the coverage-based and load-based algorithm for
pPeriod UALIT HSDPA dynamic reconfiguration of the channel mapped to
Timer YEVAL downlink SRBs.
UATE GUI Value Range: D250, D500, D1000, D2000,
D3000, D4000, D6000, D8000, D12000, D16000,
D20000, D24000, D28000, D32000, D64000
Unit: ms
Actual Value Range: 250, 500, 1000, 2000, 3000,
4000, 6000, 8000, 12000, 16000, 20000, 24000,
28000, 32000, 64000
Default Value: D2000
SrbH2D BSC691 SET WRFD- SRB Meaning: Measurement period of RSCP and Ec/N0
RabRsc 0 UCHLQ 010652 over for the coverage-based and load-based algorithm for
pPeriod UALIT HSDPA dynamic reconfiguration of the channel mapped to
Timer YEVAL downlink SRBs.
UATE GUI Value Range: D250, D500, D1000, D2000,
D3000, D4000, D6000, D8000, D12000, D16000,
D20000, D24000, D28000, D32000, D64000
Unit: ms
Actual Value Range: 250, 500, 1000, 2000, 3000,
4000, 6000, 8000, 12000, 16000, 20000, 24000,
28000, 32000, 64000
Default Value: D2000
19. PERFENH_HO_SIGNAL_SCENE_CTRL:
Whether to allow single signaling handovers for RRC
connection setup request messages indicating that no
services are initiated. This switch is turned on based
on other establishment causes rather than the
following causes. The RNC considers that services
need to be set up when the Establishment cause
IE(3GPP TS 25.331) in the
RRC_RRC_CONNECT_REQ message is set to any
of the following values: Originating Conversational
Call, Originating Streaming Call, Originating
Interactive Call, Originating Background Call,
Originating Subscribed traffic Call, Terminating
Conversational Call, Terminating Streaming Call,
Terminating Interactive Call, Terminating Background
Call, Originating High Priority Signalling, and
Terminating High Priority Signalling. When this
switch is turned on, single signaling handovers are not
allowed for RRC connection setup request messages
indicating that no services are initiated. When this
switch is turned off, single signaling handovers are
allowed for all UEs.
20.
PERFENH_PS_CMTIMEOUT_UP_LIMIT_SWITC
H: Whether UEs under weak coverage in the
downlink can initiate DCCC-based rate increasing and
HSPA retries. If the RNC receives event 2D
measurement reports but does not receive similar
event 2F measurement reports, UEs are considered to
be under weak coverage in the downlink. When this
switch is turned on, UEs under weak coverage in the
downlink cannot initiate rate increasing after the timer
for starting compressed mode expires. When this
switch is turned off, UEs can directly initiate rate
increasing after the timer for starting compressed
mode expires. This parameter is currently not for use.
21.
PERFENH_SPEC_PRD_HHO_DELAY_TIME_SWI
TCH: Whether the RNC immediately triggers
handovers upon receiving a periodic inter-frequency
or inter-RAT measurement report indicating that the
signal meets handover triggering requirements, when
the time delay for triggering handovers based on
periodical inter-frequency measurement reports/
periodical inter-RAT measurement reports is set to 0.
When this switch is turned on, inter-frequency or
inter-RAT handovers are triggered immediately. When
this switch is turned off, inter-frequency or inter-RAT
CH, PERFENH_OLPC_TBSIZE0_CMP_SWITCH,
PERFENH_UU_P2D_F2D_MSG_OPT_SWITCH,
PERFENH_DYC_INIBITRATE_MULTI_SWITCH,
PERFENH_RLRESETUP_GUARANTEE_SWITCH,
PERFENH_RLRESETUP_PREEMPT_SWITCH
Unit: None
Actual Value Range:
PERFENH_COMM_PLMN_HO_ALLOWED_SWIT
CH,
PERFENH_INITIAL_NCELLDETECT_SWITCH,
PERFENH_VP_TO_AMR_SWITCH,
PERFENH_AMRC_TFI_CMP_SWITCH,
PERFENH_MR_AGPS_CMP_SWITCH,
PERFENH_AMRC_NACK_SWITCH,
PERFENH_MCDRD_OPT_SWITCH,
PERFENH_MCDRD_MEAS_OPT_SWITCH,
PERFENH_UE_LOC_DRD_OPT_SWITCH,
PERFENH_PS_FAST_RETURN_LTE_SWITCH,
PERFENH_FORCE_AMR_INTER_RAT_OUT_SWI
TCH, PERFENH_INACTIVE_F2P_SWITCH,
PERFENH_NB_AMRC_UL_RATESET_EXT_SWIT
CH,
PERFENH_DC_USERNUM_LDB_OPT_SWITCH,
PERFENH_DCH_TRCH_OPT_SWITCH,
PERFENH_RB_MAPPING_OPT_SWITCH,
PERFENH_U2L_REDIR_WITH_BLACK_CELL_S
WITCH,
PERFENH_UL_RL_FAIL_SRV_CELL_CHG_SWIT
CH, PERFENH_HO_SIGNAL_SCENE_CTRL,
PERFENH_PS_CMTIMEOUT_UP_LIMIT_SWITC
H,
PERFENH_SPEC_PRD_HHO_DELAY_TIME_SWI
TCH,
PERFENH_BASE_COV_BE_E2D_10MS_OFF_SWI
TCH,
PERFENH_RRC_CELL_HSUPA_CAP_CHG_SWIT
CH,
PERFENH_RRC_CELL_HSDPA_CAP_CHG_SWIT
CH,
PERFENH_CELL_TTI2MS_CAP_CHG_OPT_SWIT
CH, PERFENH_OLPC_TBSIZE0_CMP_SWITCH,
PERFENH_UU_P2D_F2D_MSG_OPT_SWITCH,
PERFENH_DYC_INIBITRATE_MULTI_SWITCH,
PERFENH_RLRESETUP_GUARANTEE_SWITCH,
PERFENH_RLRESETUP_PREEMPT_SWITCH
Default Value:
PERFENH_COMM_PLMN_HO_ALLOWED_SWIT
19. PERFENH_HO_SIGNAL_SCENE_CTRL:
Whether to allow single signaling handovers for RRC
connection setup request messages indicating that no
services are initiated. This switch is turned on based
on other establishment causes rather than the
following causes. The RNC considers that services
need to be set up when the Establishment cause
IE(3GPP TS 25.331) in the
RRC_RRC_CONNECT_REQ message is set to any
of the following values: Originating Conversational
Call, Originating Streaming Call, Originating
Interactive Call, Originating Background Call,
Originating Subscribed traffic Call, Terminating
Conversational Call, Terminating Streaming Call,
Terminating Interactive Call, Terminating Background
Call, Originating High Priority Signalling, and
Terminating High Priority Signalling. When this
switch is turned on, single signaling handovers are not
allowed for RRC connection setup request messages
indicating that no services are initiated. When this
switch is turned off, single signaling handovers are
allowed for all UEs.
20.
PERFENH_PS_CMTIMEOUT_UP_LIMIT_SWITC
H: Whether UEs under weak coverage in the
downlink can initiate DCCC-based rate increasing and
HSPA retries. If the RNC receives event 2D
measurement reports but does not receive similar
event 2F measurement reports, UEs are considered to
be under weak coverage in the downlink. When this
switch is turned on, UEs under weak coverage in the
downlink cannot initiate rate increasing after the timer
for starting compressed mode expires. When this
switch is turned off, UEs can directly initiate rate
increasing after the timer for starting compressed
mode expires. This parameter is currently not for use.
21.
PERFENH_SPEC_PRD_HHO_DELAY_TIME_SWI
TCH: Whether the RNC immediately triggers
handovers upon receiving a periodic inter-frequency
or inter-RAT measurement report indicating that the
signal meets handover triggering requirements, when
the time delay for triggering handovers based on
periodical inter-frequency measurement reports/
periodical inter-RAT measurement reports is set to 0.
When this switch is turned on, inter-frequency or
inter-RAT handovers are triggered immediately. When
this switch is turned off, inter-frequency or inter-RAT
CH, PERFENH_OLPC_TBSIZE0_CMP_SWITCH,
PERFENH_UU_P2D_F2D_MSG_OPT_SWITCH,
PERFENH_DYC_INIBITRATE_MULTI_SWITCH,
PERFENH_RLRESETUP_GUARANTEE_SWITCH,
PERFENH_RLRESETUP_PREEMPT_SWITCH
Unit: None
Actual Value Range:
PERFENH_COMM_PLMN_HO_ALLOWED_SWIT
CH,
PERFENH_INITIAL_NCELLDETECT_SWITCH,
PERFENH_VP_TO_AMR_SWITCH,
PERFENH_AMRC_TFI_CMP_SWITCH,
PERFENH_MR_AGPS_CMP_SWITCH,
PERFENH_AMRC_NACK_SWITCH,
PERFENH_MCDRD_OPT_SWITCH,
PERFENH_MCDRD_MEAS_OPT_SWITCH,
PERFENH_UE_LOC_DRD_OPT_SWITCH,
PERFENH_PS_FAST_RETURN_LTE_SWITCH,
PERFENH_FORCE_AMR_INTER_RAT_OUT_SWI
TCH, PERFENH_INACTIVE_F2P_SWITCH,
PERFENH_NB_AMRC_UL_RATESET_EXT_SWIT
CH,
PERFENH_DC_USERNUM_LDB_OPT_SWITCH,
PERFENH_DCH_TRCH_OPT_SWITCH,
PERFENH_RB_MAPPING_OPT_SWITCH,
PERFENH_U2L_REDIR_WITH_BLACK_CELL_S
WITCH,
PERFENH_UL_RL_FAIL_SRV_CELL_CHG_SWIT
CH, PERFENH_HO_SIGNAL_SCENE_CTRL,
PERFENH_PS_CMTIMEOUT_UP_LIMIT_SWITC
H,
PERFENH_SPEC_PRD_HHO_DELAY_TIME_SWI
TCH,
PERFENH_BASE_COV_BE_E2D_10MS_OFF_SWI
TCH,
PERFENH_RRC_CELL_HSUPA_CAP_CHG_SWIT
CH,
PERFENH_RRC_CELL_HSDPA_CAP_CHG_SWIT
CH,
PERFENH_CELL_TTI2MS_CAP_CHG_OPT_SWIT
CH, PERFENH_OLPC_TBSIZE0_CMP_SWITCH,
PERFENH_UU_P2D_F2D_MSG_OPT_SWITCH,
PERFENH_DYC_INIBITRATE_MULTI_SWITCH,
PERFENH_RLRESETUP_GUARANTEE_SWITCH,
PERFENH_RLRESETUP_PREEMPT_SWITCH
Default Value:
PERFENH_COMM_PLMN_HO_ALLOWED_SWIT
TAC_F BSC690 ADD WRFD- Termina Meaning: The function of the TAC.If Fast_Dormancy
UNC 0 UIMEIT 160103 l Black is selected, the TAC specifies the UEs that are enabled
AC WRFD- List with the Fast Dormancy feature; if
MOD 020500 Enhance HSDPA_RB_Setup_Cmp_CRC is selected, the TAC
UIMEIT d Fast specifies that the UEs want to establish services on
AC Dorman HSDPA, however, the RNC sets up services on the
cy DCH, and retries on HSDPA later; if
RMV Special_User_Enhance is selected, the TAC specifies
UIMEIT the UEs that are enabled with the Special User
AC Enhance feature; if Video_Shaping is selected, the
TAC specifies the UEs that are enabled with the Radio
Awared Video Shaping feature. If the RNC receives a
Signaling Connection Release Indication (SCRI)
message from one of this type of UEs during video
service traffic shaping, the RNC keeps the UE in the
CELL_FACH or CELL_PCH state without releasing
the UE's RRC connection.
GUI Value Range: Fast_Dormancy,
HSDPA_RB_Setup_Cmp_CRC,
Special_User_Enhance, Video_Shaping
Unit: None
Actual Value Range: Fast_Dormancy,
HSDPA_RB_Setup_Cmp_CRC,
Special_User_Enhance, Video_Shaping
Default Value: None
TAC_F BSC691 ADD WRFD- Termina Meaning: The function of the TAC.If Fast_Dormancy
UNC 0 UIMEIT 160103 l Black is selected, the TAC specifies the UEs that are enabled
AC WRFD- List with the Fast Dormancy feature; if
MOD 020500 Enhance HSDPA_RB_Setup_Cmp_CRC is selected, the TAC
UIMEIT d Fast specifies that the UEs want to establish services on
AC Dorman HSDPA, however, the RNC sets up services on the
cy DCH, and retries on HSDPA later; if
RMV Special_User_Enhance is selected, the TAC specifies
UIMEIT the UEs that are enabled with the Special User
AC Enhance feature; if Video_Shaping is selected, the
TAC specifies the UEs that are enabled with the Radio
Awared Video Shaping feature. If the RNC receives a
Signaling Connection Release Indication (SCRI)
message from one of this type of UEs during video
service traffic shaping, the RNC keeps the UE in the
CELL_FACH or CELL_PCH state without releasing
the UE's RRC connection.
GUI Value Range: Fast_Dormancy,
HSDPA_RB_Setup_Cmp_CRC,
Special_User_Enhance, Video_Shaping
Unit: None
Actual Value Range: Fast_Dormancy,
HSDPA_RB_Setup_Cmp_CRC,
Special_User_Enhance, Video_Shaping
Default Value: None
RSVDBIT1_BIT18, RSVDBIT1_BIT19,
RSVDBIT1_BIT20, RSVDBIT1_BIT21,
RSVDBIT1_BIT22, RSVDBIT1_BIT23,
RSVDBIT1_BIT24, RSVDBIT1_BIT25,
RSVDBIT1_BIT26, RSVDBIT1_BIT27,
RSVDBIT1_BIT28, RSVDBIT1_BIT29,
RSVDBIT1_BIT30, RSVDBIT1_BIT31,
RSVDBIT1_BIT32
Default Value:
RSVDBIT1_BIT1:0,NAS_QOS_MOD_SWITCH:
1,RSVDBIT1_BIT3:0,RSVDBIT1_BIT4:0,RSVDBIT
1_BIT5:0,RSVDBIT1_BIT6:0,RSVDBIT1_BIT7:0,R
SVDBIT1_BIT8:0,RSVDBIT1_BIT9:0,RSVDBIT1_
BIT10:0,RSVDBIT1_BIT11:0,RSVDBIT1_BIT12:0,
RSVDBIT1_BIT13:0,RSVDBIT1_BIT14:0,RSVDBI
T1_BIT15:0,RSVDBIT1_BIT16:0,SYSHO_CSIN_PE
RMIT_SWITCH:
1,RSVDBIT1_BIT18:1,RSVDBIT1_BIT19:1,RSVDB
IT1_BIT20:1,RSVDBIT1_BIT21:1,RSVDBIT1_BIT2
2:1,RSVDBIT1_BIT23:1,RSVDBIT1_BIT24:1,RSV
DBIT1_BIT25:1,RSVDBIT1_BIT26:1,RSVDBIT1_B
IT27:1,RSVDBIT1_BIT28:1,RSVDBIT1_BIT29:1,R
SVDBIT1_BIT30:1,RSVDBIT1_BIT31:1,RSVDBIT
1_BIT32:1
RSVDBIT1_BIT18, RSVDBIT1_BIT19,
RSVDBIT1_BIT20, RSVDBIT1_BIT21,
RSVDBIT1_BIT22, RSVDBIT1_BIT23,
RSVDBIT1_BIT24, RSVDBIT1_BIT25,
RSVDBIT1_BIT26, RSVDBIT1_BIT27,
RSVDBIT1_BIT28, RSVDBIT1_BIT29,
RSVDBIT1_BIT30, RSVDBIT1_BIT31,
RSVDBIT1_BIT32
Default Value:
RSVDBIT1_BIT1:0,NAS_QOS_MOD_SWITCH:
1,RSVDBIT1_BIT3:0,RSVDBIT1_BIT4:0,RSVDBIT
1_BIT5:0,RSVDBIT1_BIT6:0,RSVDBIT1_BIT7:0,R
SVDBIT1_BIT8:0,RSVDBIT1_BIT9:0,RSVDBIT1_
BIT10:0,RSVDBIT1_BIT11:0,RSVDBIT1_BIT12:0,
RSVDBIT1_BIT13:0,RSVDBIT1_BIT14:0,RSVDBI
T1_BIT15:0,RSVDBIT1_BIT16:0,SYSHO_CSIN_PE
RMIT_SWITCH:
1,RSVDBIT1_BIT18:1,RSVDBIT1_BIT19:1,RSVDB
IT1_BIT20:1,RSVDBIT1_BIT21:1,RSVDBIT1_BIT2
2:1,RSVDBIT1_BIT23:1,RSVDBIT1_BIT24:1,RSV
DBIT1_BIT25:1,RSVDBIT1_BIT26:1,RSVDBIT1_B
IT27:1,RSVDBIT1_BIT28:1,RSVDBIT1_BIT29:1,R
SVDBIT1_BIT30:1,RSVDBIT1_BIT31:1,RSVDBIT
1_BIT32:1
PrdRepo BSC690 ADD WRFD- Inter Meaning: Interval between periodic measurement
rtInterva 0 UCELLI 020302 Frequen reports on an inter-frequency neighboring cell sent
l NTERF WRFD- cy Hard from a UE to the RNC. In periodic reporting mode,
REQHO 020402 Handov the UE sends measurement reports to the RNC at the
COV er Based preset interval. It is recommended not to set this
MOD on parameter to NON_PERIODIC_REPORT. Otherwise,
UCELLI Coverag the UE behavior is unknown.
NTERF e GUI Value Range: NON_PERIODIC_REPORT(Non
REQHO Measure periodical reporting), D250(D250), D500(D500),
COV ment D1000(D1000), D2000(D2000), D3000(D3000),
Based D4000(D4000), D6000(D6000), D8000(D8000),
Direct D12000(D12000), D16000(D16000),
Retry D20000(D20000), D24000(D24000),
D28000(D28000), D32000(D32000),
D64000(D64000)
Unit: ms
Actual Value Range: NON_PERIODIC_REPORT,
250, 500, 1000, 2000, 3000, 4000, 6000, 8000, 12000,
16000, 20000, 24000, 28000, 32000, 64000
Default Value: D500(D500)
PrdRepo BSC691 ADD WRFD- Inter Meaning: Interval between periodic measurement
rtInterva 0 UCELLI 020302 Frequen reports on an inter-frequency neighboring cell sent
l NTERF WRFD- cy Hard from a UE to the RNC. In periodic reporting mode,
REQHO 020402 Handov the UE sends measurement reports to the RNC at the
COV er Based preset interval. It is recommended not to set this
MOD on parameter to NON_PERIODIC_REPORT. Otherwise,
UCELLI Coverag the UE behavior is unknown.
NTERF e GUI Value Range: NON_PERIODIC_REPORT(Non
REQHO Measure periodical reporting), D250(D250), D500(D500),
COV ment D1000(D1000), D2000(D2000), D3000(D3000),
Based D4000(D4000), D6000(D6000), D8000(D8000),
Direct D12000(D12000), D16000(D16000),
Retry D20000(D20000), D24000(D24000),
D28000(D28000), D32000(D32000),
D64000(D64000)
Unit: ms
Actual Value Range: NON_PERIODIC_REPORT,
250, 500, 1000, 2000, 3000, 4000, 6000, 8000, 12000,
16000, 20000, 24000, 28000, 32000, 64000
Default Value: D500(D500)
TimeTo BSC690 ADD WRFD- Inter Meaning: Time delay to trigger event 2D. A UE
Trig2D 0 UCELLI 020302 Frequen reports an event 2D measurement report if the
NTERF cy Hard conditions for triggering event 2D are met and persist
REQHO Handov during the time period specified by this parameter.
COV er Based GUI Value Range: D0, D10, D20, D40, D60, D80,
MOD on D100, D120, D160, D200, D240, D320, D640,
UCELLI Coverag D1280, D2560, D5000
NTERF e
Unit: ms
REQHO
COV Actual Value Range: 0, 10, 20, 40, 60, 80, 100, 120,
160, 200, 240, 320, 640, 1280, 2560, 5000
Default Value: D320
TimeTo BSC691 ADD WRFD- Inter Meaning: Time delay to trigger event 2D. A UE
Trig2D 0 UCELLI 020302 Frequen reports an event 2D measurement report if the
NTERF cy Hard conditions for triggering event 2D are met and persist
REQHO Handov during the time period specified by this parameter.
COV er Based GUI Value Range: D0, D10, D20, D40, D60, D80,
MOD on D100, D120, D160, D200, D240, D320, D640,
UCELLI Coverag D1280, D2560, D5000
NTERF e
Unit: ms
REQHO
COV Actual Value Range: 0, 10, 20, 40, 60, 80, 100, 120,
160, 200, 240, 320, 640, 1280, 2560, 5000
Default Value: D320
TrigTim BSC690 ADD WRFD- Inter- Meaning: Time delay to trigger event 2D.
e2D 0 UCELLI 020303 RAT GUI Value Range: D0, D10, D20, D40, D60, D80,
NTERR Handov D100, D120, D160, D200, D240, D320, D640,
ATHOC er Based D1280, D2560, D5000
OV on
Coverag Unit: ms
MOD
UCELLI e Actual Value Range: 0, 10, 20, 40, 60, 80, 100, 120,
NTERR 160, 200, 240, 320, 640, 1280, 2560, 5000
ATHOC Default Value: D320
OV
TrigTim BSC691 ADD WRFD- Inter- Meaning: Time delay to trigger event 2D.
e2D 0 UCELLI 020303 RAT GUI Value Range: D0, D10, D20, D40, D60, D80,
NTERR Handov D100, D120, D160, D200, D240, D320, D640,
ATHOC er Based D1280, D2560, D5000
OV on
Coverag Unit: ms
MOD
UCELLI e Actual Value Range: 0, 10, 20, 40, 60, 80, 100, 120,
NTERR 160, 200, 240, 320, 640, 1280, 2560, 5000
ATHOC Default Value: D320
OV
Hystfor2 BSC690 ADD WRFD- Inter- Meaning: Hysteresis for event 2D. The hysteresis can
D 0 UCELLI 020303 RAT be evaluated based on the Ec/N0 or RSCP. For details
NTERR Handov about this parameter, see 3GPP TS 25.331.
ATHOC er Based GUI Value Range: 0~29
OV on
Coverag Unit: 0.5dB; 0.5dBm
MOD
UCELLI e Actual Value Range: 0~14.5
NTERR Default Value: 4
ATHOC
OV
Hystfor2 BSC691 ADD WRFD- Inter- Meaning: Hysteresis for event 2D. The hysteresis can
D 0 UCELLI 020303 RAT be evaluated based on the Ec/N0 or RSCP. For details
NTERR Handov about this parameter, see 3GPP TS 25.331.
ATHOC er Based GUI Value Range: 0~29
OV on
Coverag Unit: 0.5dB; 0.5dBm
MOD
UCELLI e Actual Value Range: 0~14.5
NTERR Default Value: 4
ATHOC
OV
TimeTo BSC690 ADD WRFD- Inter Meaning: Time delay to trigger event 2F. A UE
Trig2F 0 UCELLI 020302 Frequen reports an event 2F measurement report if the
NTERF cy Hard conditions for triggering event 2F are met and persist
REQHO Handov during the time period specified by this parameter.
COV er Based GUI Value Range: D0, D10, D20, D40, D60, D80,
MOD on D100, D120, D160, D200, D240, D320, D640,
UCELLI Coverag D1280, D2560, D5000
NTERF e
Unit: ms
REQHO
COV Actual Value Range: 0, 10, 20, 40, 60, 80, 100, 120,
160, 200, 240, 320, 640, 1280, 2560, 5000
Default Value: D1280
TimeTo BSC691 ADD WRFD- Inter Meaning: Time delay to trigger event 2F. A UE
Trig2F 0 UCELLI 020302 Frequen reports an event 2F measurement report if the
NTERF cy Hard conditions for triggering event 2F are met and persist
REQHO Handov during the time period specified by this parameter.
COV er Based GUI Value Range: D0, D10, D20, D40, D60, D80,
MOD on D100, D120, D160, D200, D240, D320, D640,
UCELLI Coverag D1280, D2560, D5000
NTERF e
Unit: ms
REQHO
COV Actual Value Range: 0, 10, 20, 40, 60, 80, 100, 120,
160, 200, 240, 320, 640, 1280, 2560, 5000
Default Value: D1280
TrigTim BSC690 ADD WRFD- Inter- Meaning: Time delay to trigger event 2F.
e2F 0 UCELLI 020303 RAT GUI Value Range: D0, D10, D20, D40, D60, D80,
NTERR Handov D100, D120, D160, D200, D240, D320, D640,
ATHOC er Based D1280, D2560, D5000
OV on
Coverag Unit: ms
MOD
UCELLI e Actual Value Range: 0, 10, 20, 40, 60, 80, 100, 120,
NTERR 160, 200, 240, 320, 640, 1280, 2560, 5000
ATHOC Default Value: D1280
OV
TrigTim BSC691 ADD WRFD- Inter- Meaning: Time delay to trigger event 2F.
e2F 0 UCELLI 020303 RAT GUI Value Range: D0, D10, D20, D40, D60, D80,
NTERR Handov D100, D120, D160, D200, D240, D320, D640,
ATHOC er Based D1280, D2560, D5000
OV on
Coverag Unit: ms
MOD
UCELLI e Actual Value Range: 0, 10, 20, 40, 60, 80, 100, 120,
NTERR 160, 200, 240, 320, 640, 1280, 2560, 5000
ATHOC Default Value: D1280
OV
Hystfor2 BSC690 ADD WRFD- Inter- Meaning: Hysteresis for event 2F. The hysteresis can
F 0 UCELLI 020303 RAT be evaluated based on the Ec/N0 or RSCP. For details
NTERR Handov about this parameter, see 3GPP TS 25.331.
ATHOC er Based GUI Value Range: 0~29
OV on
Coverag Unit: 0.5dB; 0.5dBm
MOD
UCELLI e Actual Value Range: 0~14.5
NTERR Default Value: 4
ATHOC
OV
Hystfor2 BSC691 ADD WRFD- Inter- Meaning: Hysteresis for event 2F. The hysteresis can
F 0 UCELLI 020303 RAT be evaluated based on the Ec/N0 or RSCP. For details
NTERR Handov about this parameter, see 3GPP TS 25.331.
ATHOC er Based GUI Value Range: 0~29
OV on
Coverag Unit: 0.5dB; 0.5dBm
MOD
UCELLI e Actual Value Range: 0~14.5
NTERR Default Value: 4
ATHOC
OV
TimeTo BSC690 ADD WRFD- Inter Meaning: Time delay to trigger event 2B. A UE
Trig2B 0 UCELLI 020302 Frequen reports an event 2B measurement report if the
NTERF WRFD- cy Hard conditions for triggering event 2B are met and persist
REQHO 020304 Handov during the time period specified by this parameter.
COV er Based GUI Value Range: D0, D10, D20, D40, D60, D80,
MOD on D100, D120, D160, D200, D240, D320, D640,
UCELLI Coverag D1280, D2560, D5000
NTERF e
Unit: ms
REQHO Inter
COV Frequen Actual Value Range: 0, 10, 20, 40, 60, 80, 100, 120,
cy Hard 160, 200, 240, 320, 640, 1280, 2560, 5000
Handov Default Value: D0
er Based
on DL
QoS
TimeTo BSC691 ADD WRFD- Inter Meaning: Time delay to trigger event 2B. A UE
Trig2B 0 UCELLI 020302 Frequen reports an event 2B measurement report if the
NTERF WRFD- cy Hard conditions for triggering event 2B are met and persist
REQHO 020304 Handov during the time period specified by this parameter.
COV er Based GUI Value Range: D0, D10, D20, D40, D60, D80,
MOD on D100, D120, D160, D200, D240, D320, D640,
UCELLI Coverag D1280, D2560, D5000
NTERF e
Unit: ms
REQHO Inter
COV Frequen Actual Value Range: 0, 10, 20, 40, 60, 80, 100, 120,
cy Hard 160, 200, 240, 320, 640, 1280, 2560, 5000
Handov Default Value: D0
er Based
on DL
QoS
HystFor BSC690 ADD WRFD- Inter Meaning: Event 2B hysteresis. The hysteresis can be
2B 0 UCELLI 020302 Frequen the Ec/No or RSCP. For details, see 3GPP TS 25.331.
NTERF cy Hard GUI Value Range: 0~29
REQHO Handov
COV er Based Unit: 0.5dB; 0.5dBm
HystFor BSC691 ADD WRFD- Inter Meaning: Event 2B hysteresis. The hysteresis can be
2B 0 UCELLI 020302 Frequen the Ec/No or RSCP. For details, see 3GPP TS 25.331.
NTERF cy Hard GUI Value Range: 0~29
REQHO Handov
COV er Based Unit: 0.5dB; 0.5dBm
TargetFr BSC690 ADD WRFD- Inter Meaning: Threshold of the target frequency for
eqCsTh 0 UCELLI 020302 Frequen triggering inter-frequency measurement based on
dEcN0 NTERF cy Hard measurement quantity of Ec/No for CS services. For
REQHO Handov CS services, if the inter-frequency reporting mode is
COV er Based set to "EVENT_TRIGGER", this parameter is used to
MOD on set the criterion for triggering event 2B. That is, event
UCELLI Coverag 2B can be triggered when the quality of the target
NTERF e frequency is higher than this threshold. If the inter-
REQHO frequency reporting mode is set to
COV "PERIODIC_TRIGGER", this parameter is used for
handover decision.
GUI Value Range: -24~0
Unit: dB
Actual Value Range: -24~0
Default Value: -12
TargetFr BSC691 ADD WRFD- Inter Meaning: Threshold of the target frequency for
eqCsTh 0 UCELLI 020302 Frequen triggering inter-frequency measurement based on
dEcN0 NTERF cy Hard measurement quantity of Ec/No for CS services. For
REQHO Handov CS services, if the inter-frequency reporting mode is
COV er Based set to "EVENT_TRIGGER", this parameter is used to
MOD on set the criterion for triggering event 2B. That is, event
UCELLI Coverag 2B can be triggered when the quality of the target
NTERF e frequency is higher than this threshold. If the inter-
REQHO frequency reporting mode is set to
COV "PERIODIC_TRIGGER", this parameter is used for
handover decision.
GUI Value Range: -24~0
Unit: dB
Actual Value Range: -24~0
Default Value: -12
TargetFr BSC690 ADD WRFD- Inter Meaning: Threshold of the target frequency for
eqCsTh 0 UCELLI 020302 Frequen triggering inter-frequency measurement based on
dRscp NTERF cy Hard measurement quantity of RSCP for CS services. For
REQHO Handov CS services, if the inter-frequency reporting mode is
COV er Based set to "EVENT_TRIGGER", this parameter is used to
MOD on set the criterion for triggering event 2B. That is, event
UCELLI Coverag 2B can be triggered when the quality of the target
NTERF e frequency is higher than this threshold. If the inter-
REQHO frequency reporting mode is set to
COV "PERIODIC_TRIGGER", this parameter is used for
handover decision.
GUI Value Range: -115~-25
Unit: dBm
Actual Value Range: -115~-25
Default Value: -92
TargetFr BSC691 ADD WRFD- Inter Meaning: Threshold of the target frequency for
eqCsTh 0 UCELLI 020302 Frequen triggering inter-frequency measurement based on
dRscp NTERF cy Hard measurement quantity of RSCP for CS services. For
REQHO Handov CS services, if the inter-frequency reporting mode is
COV er Based set to "EVENT_TRIGGER", this parameter is used to
MOD on set the criterion for triggering event 2B. That is, event
UCELLI Coverag 2B can be triggered when the quality of the target
NTERF e frequency is higher than this threshold. If the inter-
REQHO frequency reporting mode is set to
COV "PERIODIC_TRIGGER", this parameter is used for
handover decision.
GUI Value Range: -115~-25
Unit: dBm
Actual Value Range: -115~-25
Default Value: -92
TargetFr BSC690 ADD WRFD- Inter Meaning: Threshold of the target frequency for
eqR99Ps 0 UCELLI 020302 Frequen triggering inter-frequency measurement based on
ThdEcN NTERF cy Hard measurement quantity of Ec/No for non-HSPA
0 REQHO Handov services in PS domain.For non-HSPA services in PS
COV er Based domain, if the inter-frequency reporting mode is set to
MOD on "EVENT_TRIGGER", this parameter is used to set
UCELLI Coverag the criterion for triggering event 2B. That is, event 2B
NTERF e can be triggered when the quality of the target
REQHO frequency is higher than this threshold. If the inter-
COV frequency reporting mode is set to
"PERIODIC_TRIGGER", this parameter is used for
handover decision.
GUI Value Range: -24~0
Unit: dB
Actual Value Range: -24~0
Default Value: -12
TargetFr BSC691 ADD WRFD- Inter Meaning: Threshold of the target frequency for
eqR99Ps 0 UCELLI 020302 Frequen triggering inter-frequency measurement based on
ThdEcN NTERF cy Hard measurement quantity of Ec/No for non-HSPA
0 REQHO Handov services in PS domain.For non-HSPA services in PS
COV er Based domain, if the inter-frequency reporting mode is set to
MOD on "EVENT_TRIGGER", this parameter is used to set
UCELLI Coverag the criterion for triggering event 2B. That is, event 2B
NTERF e can be triggered when the quality of the target
REQHO frequency is higher than this threshold. If the inter-
COV frequency reporting mode is set to
"PERIODIC_TRIGGER", this parameter is used for
handover decision.
GUI Value Range: -24~0
Unit: dB
Actual Value Range: -24~0
Default Value: -12
TargetFr BSC690 ADD WRFD- Inter Meaning: Threshold of the target frequency for
eqR99Ps 0 UCELLI 020302 Frequen triggering inter-frequency measurement based on
ThdRsc NTERF cy Hard measurement quantity of RSCP for non-HSPA
p REQHO Handov services in PS domain.For non-HSPA services in PS
COV er Based domain, if the inter-frequency reporting mode is set to
MOD on "EVENT_TRIGGER", this parameter is used to set
UCELLI Coverag the criterion for triggering event 2B. That is, event 2B
NTERF e can be triggered when the quality of the target
REQHO frequency is higher than this threshold. If the inter-
COV frequency reporting mode is set to
"PERIODIC_TRIGGER", this parameter is used for
handover decision.
GUI Value Range: -115~-25
Unit: dBm
Actual Value Range: -115~-25
Default Value: -92
TargetFr BSC691 ADD WRFD- Inter Meaning: Threshold of the target frequency for
eqR99Ps 0 UCELLI 020302 Frequen triggering inter-frequency measurement based on
ThdRsc NTERF cy Hard measurement quantity of RSCP for non-HSPA
p REQHO Handov services in PS domain.For non-HSPA services in PS
COV er Based domain, if the inter-frequency reporting mode is set to
MOD on "EVENT_TRIGGER", this parameter is used to set
UCELLI Coverag the criterion for triggering event 2B. That is, event 2B
NTERF e can be triggered when the quality of the target
REQHO frequency is higher than this threshold. If the inter-
COV frequency reporting mode is set to
"PERIODIC_TRIGGER", this parameter is used for
handover decision.
GUI Value Range: -115~-25
Unit: dBm
Actual Value Range: -115~-25
Default Value: -92
TargetFr BSC690 ADD WRFD- Inter Meaning: Threshold of the target frequency for
eqHThd 0 UCELLI 020302 Frequen triggering inter-frequency measurement based on
EcN0 NTERF cy Hard measurement quantity of Ec/No for HSPA
REQHO Handov services.For HSPA services, if the inter-frequency
COV er Based reporting mode is set to "EVENT_TRIGGER", this
MOD on parameter is used to set the criterion for triggering
UCELLI Coverag event 2B. That is, event 2B can be triggered when the
NTERF e quality of the target frequency is higher than this
REQHO threshold. If the inter-frequency reporting mode is set
COV to "PERIODIC_TRIGGER", this parameter is used for
handover decision.
GUI Value Range: -24~0
Unit: dB
Actual Value Range: -24~0
Default Value: -12
TargetFr BSC691 ADD WRFD- Inter Meaning: Threshold of the target frequency for
eqHThd 0 UCELLI 020302 Frequen triggering inter-frequency measurement based on
EcN0 NTERF cy Hard measurement quantity of Ec/No for HSPA
REQHO Handov services.For HSPA services, if the inter-frequency
COV er Based reporting mode is set to "EVENT_TRIGGER", this
MOD on parameter is used to set the criterion for triggering
UCELLI Coverag event 2B. That is, event 2B can be triggered when the
NTERF e quality of the target frequency is higher than this
REQHO threshold. If the inter-frequency reporting mode is set
COV to "PERIODIC_TRIGGER", this parameter is used for
handover decision.
GUI Value Range: -24~0
Unit: dB
Actual Value Range: -24~0
Default Value: -12
TargetFr BSC690 ADD WRFD- Inter Meaning: Threshold of the target frequency for
eqHThd 0 UCELLI 020302 Frequen triggering inter-frequency measurement based on
Rscp NTERF cy Hard measurement quantity of RSCP for HSPA services.
REQHO Handov For HSPA services, if the inter-frequency reporting
COV er Based mode is set to "EVENT_TRIGGER", this parameter is
MOD on used to set the criterion for triggering event 2B. That
UCELLI Coverag is, event 2B can be triggered when the quality of the
NTERF e target frequency is higher than this threshold. If the
REQHO inter-frequency reporting mode is set to
COV "PERIODIC_TRIGGER", this parameter is used for
handover decision. After handover, to prevent ping-
pong handover, the inter-frequency measurement
should not be started again. That is, this parameter is
usually set greater than the start threshold for event
2D or equal to the threshold of event 2F.
GUI Value Range: -115~-25
Unit: dBm
Actual Value Range: -115~-25
Default Value: -92
TargetFr BSC691 ADD WRFD- Inter Meaning: Threshold of the target frequency for
eqHThd 0 UCELLI 020302 Frequen triggering inter-frequency measurement based on
Rscp NTERF cy Hard measurement quantity of RSCP for HSPA services.
REQHO Handov For HSPA services, if the inter-frequency reporting
COV er Based mode is set to "EVENT_TRIGGER", this parameter is
MOD on used to set the criterion for triggering event 2B. That
UCELLI Coverag is, event 2B can be triggered when the quality of the
NTERF e target frequency is higher than this threshold. If the
REQHO inter-frequency reporting mode is set to
COV "PERIODIC_TRIGGER", this parameter is used for
handover decision. After handover, to prevent ping-
pong handover, the inter-frequency measurement
should not be started again. That is, this parameter is
usually set greater than the start threshold for event
2D or equal to the threshold of event 2F.
GUI Value Range: -115~-25
Unit: dBm
Actual Value Range: -115~-25
Default Value: -92
TrigTim BSC690 ADD WRFD- Inter- Meaning: Time delay to trigger event 3A.
e3A 0 UCELLI 020303 RAT GUI Value Range: D0, D10, D20, D40, D60, D80,
NTERR Handov D100, D120, D160, D200, D240, D320, D640,
ATHOC er Based D1280, D2560, D5000
OV on
Coverag Unit: ms
MOD
UCELLI e Actual Value Range: 0, 10, 20, 40, 60, 80, 100, 120,
NTERR 160, 200, 240, 320, 640, 1280, 2560, 5000
ATHOC Default Value: D0
OV
TrigTim BSC691 ADD WRFD- Inter- Meaning: Time delay to trigger event 3A.
e3A 0 UCELLI 020303 RAT GUI Value Range: D0, D10, D20, D40, D60, D80,
NTERR Handov D100, D120, D160, D200, D240, D320, D640,
ATHOC er Based D1280, D2560, D5000
OV on
Coverag Unit: ms
MOD
UCELLI e Actual Value Range: 0, 10, 20, 40, 60, 80, 100, 120,
NTERR 160, 200, 240, 320, 640, 1280, 2560, 5000
ATHOC Default Value: D0
OV
Unit: dBm
Actual Value Range: -110~-48(Actual value meets the
condition: Actual Value = GUI Value - 111)
Default Value: 16
Unit: dBm
Actual Value Range: -110~-48(Actual value meets the
condition: Actual Value = GUI Value - 111)
Default Value: 16
Penalty BSC690 SET WRFD- Inter- Meaning: Penalty timer on compressed mode after
TimerFo 0 UHOCO 020309 RAT coverage-based measurement expires. After coverage-
rCMFail MM WRFD- Handov based inter-frequency measurement (inter-RAT or
Cov 020302 er Based UMTS-to-LTE) expires, this timer is started and a UE
on DL cannot start the compressed mode for inter-frequency
WRFD- QoS measurement (inter-RAT or UMTS-to-LTE) during the
020303 period specified by this timer.
Inter
WRFD- Frequen GUI Value Range: 0~65535
020304 cy Hard Unit: s
Handov
er Based Actual Value Range: 0~65535
on Default Value: 10
Coverag
e
Inter-
RAT
Handov
er Based
on
Coverag
e
Inter
Frequen
cy Hard
Handov
er Based
on DL
QoS
Penalty BSC691 SET WRFD- Inter- Meaning: Penalty timer on compressed mode after
TimerFo 0 UHOCO 020309 RAT coverage-based measurement expires. After coverage-
rCMFail MM WRFD- Handov based inter-frequency measurement (inter-RAT or
Cov 020302 er Based UMTS-to-LTE) expires, this timer is started and a UE
on DL cannot start the compressed mode for inter-frequency
WRFD- QoS measurement (inter-RAT or UMTS-to-LTE) during the
020303 period specified by this timer.
Inter
WRFD- Frequen GUI Value Range: 0~65535
020304 cy Hard Unit: s
Handov
er Based Actual Value Range: 0~65535
on Default Value: 10
Coverag
e
Inter-
RAT
Handov
er Based
on
Coverag
e
Inter
Frequen
cy Hard
Handov
er Based
on DL
QoS
CsBSIC BSC690 ADD WRFD- Inter- Meaning: Whether to perform initial BSIC
VerifyIn 0 UCELLI 020303 RAT identification or BSIC reconfirmation during inter-
dication NTERR WRFD- Handov RAT signal quality measurement for CS services.
ATHOC 020305 er Based GUI Value Range: BSICINIT_AND_RECONFIRM,
OV on BSICINIT
WRFD- Coverag
MOD 020306 Unit: None
UCELLI e
NTERR WRFD- Inter- Actual Value Range:
ATHOC 020402 RAT BSICINIT_AND_RECONFIRM, BSICINIT
OV Handov Default Value: BSICINIT_AND_RECONFIRM
er Based
on
Service
Inter-
RAT
Handov
er Based
on Load
Measure
ment
Based
Direct
Retry
CsBSIC BSC691 ADD WRFD- Inter- Meaning: Whether to perform initial BSIC
VerifyIn 0 UCELLI 020303 RAT identification or BSIC reconfirmation during inter-
dication NTERR WRFD- Handov RAT signal quality measurement for CS services.
ATHOC 020305 er Based GUI Value Range: BSICINIT_AND_RECONFIRM,
OV on BSICINIT
WRFD- Coverag
MOD 020306 Unit: None
UCELLI e
NTERR WRFD- Inter- Actual Value Range:
ATHOC 020402 RAT BSICINIT_AND_RECONFIRM, BSICINIT
OV Handov Default Value: BSICINIT_AND_RECONFIRM
er Based
on
Service
Inter-
RAT
Handov
er Based
on Load
Measure
ment
Based
Direct
Retry
PsBSIC BSC690 ADD WRFD- Inter- Meaning: Whether to perform initial BSIC
VerifyIn 0 UCELLI 020303 RAT identification or BSIC reconfirmation during inter-
dication NTERR WRFD- Handov RAT signal quality measurement for PS services.
ATHOC 020305 er Based GUI Value Range: BSICINIT_AND_RECONFIRM,
OV on BSICINIT, BSICINIT_ADPT
WRFD- Coverag
MOD 020306 Unit: None
UCELLI e
NTERR WRFD- Inter- Actual Value Range:
ATHOC 020402 RAT BSICINIT_AND_RECONFIRM, BSICINIT,
OV Handov BSICINIT_ADPT
er Based Default Value: BSICINIT_AND_RECONFIRM
on
Service
Inter-
RAT
Handov
er Based
on Load
Measure
ment
Based
Direct
Retry
PsBSIC BSC691 ADD WRFD- Inter- Meaning: Whether to perform initial BSIC
VerifyIn 0 UCELLI 020303 RAT identification or BSIC reconfirmation during inter-
dication NTERR WRFD- Handov RAT signal quality measurement for PS services.
ATHOC 020305 er Based GUI Value Range: BSICINIT_AND_RECONFIRM,
OV on BSICINIT, BSICINIT_ADPT
WRFD- Coverag
MOD 020306 Unit: None
UCELLI e
NTERR WRFD- Inter- Actual Value Range:
ATHOC 020402 RAT BSICINIT_AND_RECONFIRM, BSICINIT,
OV Handov BSICINIT_ADPT
er Based Default Value: BSICINIT_AND_RECONFIRM
on
Service
Inter-
RAT
Handov
er Based
on Load
Measure
ment
Based
Direct
Retry
RESERVED_SWITCH_11_BIT4,
RESERVED_SWITCH_11_BIT5,
RESERVED_SWITCH_11_BIT6,
RESERVED_SWITCH_11_BIT7,
RESERVED_SWITCH_11_BIT8,
RESERVED_SWITCH_11_BIT9,
RESERVED_SWITCH_11_BIT10,
RESERVED_SWITCH_11_BIT11,
RESERVED_SWITCH_11_BIT12,
RESERVED_SWITCH_11_BIT13,
RESERVED_SWITCH_11_BIT14,
RESERVED_SWITCH_11_BIT15,
RESERVED_SWITCH_11_BIT16,
RESERVED_SWITCH_11_BIT17,
RESERVED_SWITCH_11_BIT18,
RESERVED_SWITCH_11_BIT19,
RESERVED_SWITCH_11_BIT20,
RESERVED_SWITCH_11_BIT21,
RESERVED_SWITCH_11_BIT22,
RESERVED_SWITCH_11_BIT23,
RESERVED_SWITCH_11_BIT24,
RESERVED_SWITCH_11_BIT25,
RESERVED_SWITCH_11_BIT26,
RESERVED_SWITCH_11_BIT27,
RESERVED_SWITCH_11_BIT28,
RESERVED_SWITCH_11_BIT29,
RESERVED_SWITCH_11_BIT30,
RESERVED_SWITCH_11_BIT31,
RESERVED_SWITCH_11_BIT32
Default Value:
RESERVED_SWITCH_11_BIT1:0,RESERVED_SW
ITCH_11_BIT2:0,RESERVED_SWITCH_11_BIT3:0
,RESERVED_SWITCH_11_BIT4:0,RESERVED_SW
ITCH_11_BIT5:0,RESERVED_SWITCH_11_BIT6:0
,RESERVED_SWITCH_11_BIT7:0,RESERVED_SW
ITCH_11_BIT8:0,RESERVED_SWITCH_11_BIT9:0
,RESERVED_SWITCH_11_BIT10:0,RESERVED_S
WITCH_11_BIT11:0,RESERVED_SWITCH_11_BIT
12:0,RESERVED_SWITCH_11_BIT13:0,RESERVE
D_SWITCH_11_BIT14:0,RESERVED_SWITCH_11
_BIT15:0,RESERVED_SWITCH_11_BIT16:0,RESE
RVED_SWITCH_11_BIT17:0,RESERVED_SWITC
H_11_BIT18:0,RESERVED_SWITCH_11_BIT19:0,
RESERVED_SWITCH_11_BIT20:0,RESERVED_S
WITCH_11_BIT21:0,RESERVED_SWITCH_11_BIT
22:0,RESERVED_SWITCH_11_BIT23:0,RESERVE
D_SWITCH_11_BIT24:0,RESERVED_SWITCH_11
_BIT25:0,RESERVED_SWITCH_11_BIT26:0,RESE
RVED_SWITCH_11_BIT27:0,RESERVED_SWITC
H_11_BIT28:0,RESERVED_SWITCH_11_BIT29:0,
RESERVED_SWITCH_11_BIT30:0,RESERVED_S
WITCH_11_BIT31:0,RESERVED_SWITCH_11_BIT
32:0
RESERVED_SWITCH_11_BIT4,
RESERVED_SWITCH_11_BIT5,
RESERVED_SWITCH_11_BIT6,
RESERVED_SWITCH_11_BIT7,
RESERVED_SWITCH_11_BIT8,
RESERVED_SWITCH_11_BIT9,
RESERVED_SWITCH_11_BIT10,
RESERVED_SWITCH_11_BIT11,
RESERVED_SWITCH_11_BIT12,
RESERVED_SWITCH_11_BIT13,
RESERVED_SWITCH_11_BIT14,
RESERVED_SWITCH_11_BIT15,
RESERVED_SWITCH_11_BIT16,
RESERVED_SWITCH_11_BIT17,
RESERVED_SWITCH_11_BIT18,
RESERVED_SWITCH_11_BIT19,
RESERVED_SWITCH_11_BIT20,
RESERVED_SWITCH_11_BIT21,
RESERVED_SWITCH_11_BIT22,
RESERVED_SWITCH_11_BIT23,
RESERVED_SWITCH_11_BIT24,
RESERVED_SWITCH_11_BIT25,
RESERVED_SWITCH_11_BIT26,
RESERVED_SWITCH_11_BIT27,
RESERVED_SWITCH_11_BIT28,
RESERVED_SWITCH_11_BIT29,
RESERVED_SWITCH_11_BIT30,
RESERVED_SWITCH_11_BIT31,
RESERVED_SWITCH_11_BIT32
Default Value:
RESERVED_SWITCH_11_BIT1:0,RESERVED_SW
ITCH_11_BIT2:0,RESERVED_SWITCH_11_BIT3:0
,RESERVED_SWITCH_11_BIT4:0,RESERVED_SW
ITCH_11_BIT5:0,RESERVED_SWITCH_11_BIT6:0
,RESERVED_SWITCH_11_BIT7:0,RESERVED_SW
ITCH_11_BIT8:0,RESERVED_SWITCH_11_BIT9:0
,RESERVED_SWITCH_11_BIT10:0,RESERVED_S
WITCH_11_BIT11:0,RESERVED_SWITCH_11_BIT
12:0,RESERVED_SWITCH_11_BIT13:0,RESERVE
D_SWITCH_11_BIT14:0,RESERVED_SWITCH_11
_BIT15:0,RESERVED_SWITCH_11_BIT16:0,RESE
RVED_SWITCH_11_BIT17:0,RESERVED_SWITC
H_11_BIT18:0,RESERVED_SWITCH_11_BIT19:0,
RESERVED_SWITCH_11_BIT20:0,RESERVED_S
WITCH_11_BIT21:0,RESERVED_SWITCH_11_BIT
22:0,RESERVED_SWITCH_11_BIT23:0,RESERVE
D_SWITCH_11_BIT24:0,RESERVED_SWITCH_11
_BIT25:0,RESERVED_SWITCH_11_BIT26:0,RESE
RVED_SWITCH_11_BIT27:0,RESERVED_SWITC
H_11_BIT28:0,RESERVED_SWITCH_11_BIT29:0,
RESERVED_SWITCH_11_BIT30:0,RESERVED_S
WITCH_11_BIT31:0,RESERVED_SWITCH_11_BIT
32:0
HystFor BSC690 ADD WRFD- Intra Meaning: Hysteresis for the inter-frequency hard
PrdInter 0 UCELLI 020201 Node B handover. This parameter is reported periodically.
Freq NTERF WRFD- Softer This parameter is used to estimate the inter-frequency
REQHO 020402 Handov handover on the RNC.
COV er GUI Value Range: 0~29
MOD Measure Unit: 0.5dB; 0.5dBm
UCELLI ment
NTERF Based Actual Value Range: 0~14.5
REQHO Direct Default Value: 0
COV Retry
HystFor BSC691 ADD WRFD- Intra Meaning: Hysteresis for the inter-frequency hard
PrdInter 0 UCELLI 020201 Node B handover. This parameter is reported periodically.
Freq NTERF WRFD- Softer This parameter is used to estimate the inter-frequency
REQHO 020402 Handov handover on the RNC.
COV er GUI Value Range: 0~29
MOD Measure Unit: 0.5dB; 0.5dBm
UCELLI ment
NTERF Based Actual Value Range: 0~14.5
REQHO Direct Default Value: 0
COV Retry
InterFre BSC690 ADD WRFD- Inter Meaning: Whether the RNC considers the RTWP of
qHOCo 0 UCELLI 020302 Frequen the target cell when performing coverage-based inter-
nsiderR NTERF cy Hard frequency handovers. When this switch is set to on,
TWPSw REQHO Handov the RNC performs coverage-based inter-frequency
COV er Based handovers only when the uplink coverage (RTWP) of
MOD on the target cell meets certain conditions. When this
UCELLI Coverag switch is set to off, the RNC does not consider the
NTERF e uplink coverage of the target cell when performing
REQHO coverage-based inter-frequency handovers.
COV GUI Value Range: OFF, ON
Unit: None
Actual Value Range: OFF, ON
Default Value: OFF
InterFre BSC691 ADD WRFD- Inter Meaning: Whether the RNC considers the RTWP of
qHOCo 0 UCELLI 020302 Frequen the target cell when performing coverage-based inter-
nsiderR NTERF cy Hard frequency handovers. When this switch is set to on,
TWPSw REQHO Handov the RNC performs coverage-based inter-frequency
COV er Based handovers only when the uplink coverage (RTWP) of
MOD on the target cell meets certain conditions. When this
UCELLI Coverag switch is set to off, the RNC does not consider the
NTERF e uplink coverage of the target cell when performing
REQHO coverage-based inter-frequency handovers.
COV GUI Value Range: OFF, ON
Unit: None
Actual Value Range: OFF, ON
Default Value: OFF
TimeTo BSC690 ADD WRFD- Inter Meaning: Interval between reception of periodical
TrigFor 0 UCELLI 020302 Frequen reports and triggering of the inter-frequency handover.
PrdInter NTERF WRFD- cy Hard GUI Value Range: 0~64000
Freq REQHO 020402 Handov
COV er Based Unit: ms
TimeTo BSC691 ADD WRFD- Inter Meaning: Interval between reception of periodical
TrigFor 0 UCELLI 020302 Frequen reports and triggering of the inter-frequency handover.
PrdInter NTERF WRFD- cy Hard GUI Value Range: 0~64000
Freq REQHO 020402 Handov
COV er Based Unit: ms
HystforI BSC690 ADD WRFD- Inter- Meaning: Hysteresis for inter-RAT periodic reporting.
nterRAT 0 UCELLI 020303 RAT The hysteresis can be evaluated based on the Ec/N0 or
NTERR Handov RSCP. For details about this parameter, see 3GPP TS
ATHOC er Based 25.331.
OV on GUI Value Range: 0~15
MOD Coverag
e Unit: 0.5dB
UCELLI
NTERR Actual Value Range: 0~7.5
ATHOC Default Value: 0
OV
HystforI BSC691 ADD WRFD- Inter- Meaning: Hysteresis for inter-RAT periodic reporting.
nterRAT 0 UCELLI 020303 RAT The hysteresis can be evaluated based on the Ec/N0 or
NTERR Handov RSCP. For details about this parameter, see 3GPP TS
ATHOC er Based 25.331.
OV on GUI Value Range: 0~15
MOD Coverag
e Unit: 0.5dB
UCELLI
NTERR Actual Value Range: 0~7.5
ATHOC Default Value: 0
OV
BSICVe BSC690 ADD WRFD- Inter- Meaning: This parameter is used to control cells
rify 0 UCELLI 020303 RAT where inter-RAT measurement reports are triggered. If
NTERR WRFD- Handov this parameter is set to REQUIRED, the measurement
ATHOC 020305 er Based reporting is triggered after the BSIC of the measured
OV on cell is decoded correctly. If the parameter is set to
WRFD- Coverag NOT_REQUIRE, the measurement reporting is
MOD 020306
UCELLI e triggered regardless of whether the BSIC of the
NTERR WRFD- Inter- measured cell is decoded correctly. This parameter is
ATHOC 020402 RAT valid for both periodical reporting mode and event-
OV Handov triggered reporting mode. However, to ensure
er Based handover reliability, it is recommended that the
on system reports only the cells whose BSIC is decoded
Service correctly. If this parameter is set to
NOT_REQUIRED, handovers are likely to be
Inter- triggered, but handover reliability is lower than that in
RAT the situation this parameter is set to REQUIRED.
Handov
er Based GUI Value Range: REQUIRED(Verify mode),
on Load NOT_REQUIRE(Non-verify mode)
Measure Unit: None
ment Actual Value Range: REQUIRED, NOT_REQUIRE
Based Default Value: REQUIRED(Verify mode)
Direct
Retry
BSICVe BSC691 ADD WRFD- Inter- Meaning: This parameter is used to control cells
rify 0 UCELLI 020303 RAT where inter-RAT measurement reports are triggered. If
NTERR WRFD- Handov this parameter is set to REQUIRED, the measurement
ATHOC 020305 er Based reporting is triggered after the BSIC of the measured
OV on cell is decoded correctly. If the parameter is set to
WRFD- Coverag NOT_REQUIRE, the measurement reporting is
MOD 020306
UCELLI e triggered regardless of whether the BSIC of the
NTERR WRFD- Inter- measured cell is decoded correctly. This parameter is
ATHOC 020402 RAT valid for both periodical reporting mode and event-
OV Handov triggered reporting mode. However, to ensure
er Based handover reliability, it is recommended that the
on system reports only the cells whose BSIC is decoded
Service correctly. If this parameter is set to
NOT_REQUIRED, handovers are likely to be
Inter- triggered, but handover reliability is lower than that in
RAT the situation this parameter is set to REQUIRED.
Handov
er Based GUI Value Range: REQUIRED(Verify mode),
on Load NOT_REQUIRE(Non-verify mode)
Measure Unit: None
ment Actual Value Range: REQUIRED, NOT_REQUIRE
Based Default Value: REQUIRED(Verify mode)
Direct
Retry
UsedIR BSC690 ADD WRFD- Inter- Meaning: Lower Ec/No threshold for an intra-
ATHOL 0 UCELLI 020303 RAT frequency neighboring cell when an inter-RAT
owerTh NTERR Handov handover is to be implemented. If the Ec/No reported
dEcNo ATHOC er Based by the serving cell is lower than this threshold, an
OV on inter-RAT handover is not implemented. Otherwise,
MOD Coverag an inter-RAT handover is implemented.
UCELLI e GUI Value Range: -24~0
NTERR Unit: dB
ATHOC
OV Actual Value Range: -24~0
Default Value: -18
UsedIR BSC691 ADD WRFD- Inter- Meaning: Lower Ec/No threshold for an intra-
ATHOL 0 UCELLI 020303 RAT frequency neighboring cell when an inter-RAT
owerTh NTERR Handov handover is to be implemented. If the Ec/No reported
dEcNo ATHOC er Based by the serving cell is lower than this threshold, an
OV on inter-RAT handover is not implemented. Otherwise,
MOD Coverag an inter-RAT handover is implemented.
UCELLI e GUI Value Range: -24~0
NTERR Unit: dB
ATHOC
OV Actual Value Range: -24~0
Default Value: -18
UsedIR BSC690 ADD WRFD- Inter- Meaning: Upper Ec/No threshold for an intra-
ATHOU 0 UCELLI 020303 RAT frequency neighboring cell when an inter-RAT
pperThd NTERR Handov handover is to be implemented. If the Ec/No reported
EcNo ATHOC er Based by the serving cell exceeds this threshold, an inter-
OV on RAT handover is not implemented. Otherwise, an
MOD Coverag inter-RAT handover is implemented.
UCELLI e GUI Value Range: -24~0
NTERR Unit: dB
ATHOC
OV Actual Value Range: -24~0
Default Value: 0
UsedIR BSC691 ADD WRFD- Inter- Meaning: Upper Ec/No threshold for an intra-
ATHOU 0 UCELLI 020303 RAT frequency neighboring cell when an inter-RAT
pperThd NTERR Handov handover is to be implemented. If the Ec/No reported
EcNo ATHOC er Based by the serving cell exceeds this threshold, an inter-
OV on RAT handover is not implemented. Otherwise, an
MOD Coverag inter-RAT handover is implemented.
UCELLI e GUI Value Range: -24~0
NTERR Unit: dB
ATHOC
OV Actual Value Range: -24~0
Default Value: 0
g this switch is turned on, the RNC filters out the list for
Connect measured neighboring LTE cells according to the
ion Re- RNC-level parameters, cell capability, and UE
establish capabilities in handovers and redirections to the LTE
ment network. When this switch is turned off, the RNC
(DSCR) does not filter out the list for measured neighboring
Inter- LTE cells.
RAT 8. PERFENH_GSM_NCELL_SEL_OPT_SWITCH:
Handov Scope for matching the neighboring cells in
er Based measurement reports during handovers to GSM cells
on Load when there are multiple cells in the active set and the
HO_MC_NCELL_COMBINE_SWITCH switch is
turned on. In case of neighboring combination, when
this switch is turned on, the RNC matches the
neighboring cells in measurement reports with
neighboring cells of all cells in the current active set.
When this switch is turned off, the RNC matches the
neighboring cells in measurement reports only with
the best cell's neighboring cells.
9.
PERFENH_U2L_REDIR_BASED_FREQ_OPT_SWI
TCH: Whether to select the best target frequency
during a frequency-based redirection from UMTS to
LTE. When this switch is turned on, the selected target
frequency is used as the best frequency if the
measurement report contains multiple neighboring
cells that work at the same frequency.
10.
PERFENH_ICMP_ACCELERATOR_OPT_SWITCH
: Switch for the enhanced algorithm of accelerating
the rate for responding to control messages. This
parameter is a professional parameter and therefore
you must configure this parameter under the
instruction of Huawei technical support.For
RTT(round-trip time) tests, the recommended value is
ON. In other scenarios, the recommended value is
OFF.
11. PERFENH_MULTI_PS_DCCC_SWITCH:
Whether to allocate the RLC parameters
corresponding to the 2 ms TTI to the services that are
not reconfigured during the reconfiguration procedure
and have a data rate higher than 2048 kbit/s. The 2048
kbit/s is the maximum data rate supported by the 10
ms TTI. When this switch is turned on, the RNC
allocates such services the RLC parameters
corresponding to the 2 ms TTI. When this switch is
turned off. The RNC does not include the new SPI
weight adjustment factor in the Radio Link
Reconfiguration Prepare message.
GUI Value Range:
PERFENH_RCS_PS_DL_ON_DCH_SWITCH,
PERFENH_HSUPA_CAP_CHG_HRETRY_LMT_S
WITCH,
PERFENH_MC_OPT_AFTER_RETRANS_CHG_S
WITCH,
PERFENH_CSOVERH_H2D_RBID_CHG_SWITCH
,
PERFENH_RRC_DRD_FAILED_RED_GSM_SWIT
CH,
PERFENH_IRAT_COV_HO_NCELL_PRE_SWITC
H, PERFENH_LTE_NCELL_SEL_OPT_SWITCH,
PERFENH_GSM_NCELL_SEL_OPT_SWITCH,
PERFENH_U2L_REDIR_BASED_FREQ_OPT_SWI
TCH,
PERFENH_ICMP_ACCELERATOR_OPT_SWITCH
, PERFENH_MULTI_PS_DCCC_SWITCH,
PERFENH_CHL_CHG_FAIL_MC_OLPC_OPT_SW
ITCH,
PERFENH_SET2MBR_ALLOW_D2F_SWITCH,
PERFENH_RAB_REL_WITH_PS_D2F_OPT_SWIT
CH,
PERFENH_DRNC_CU_WITHOUT_EXTCELL_SW
ITCH,
PERFENH_HO_NODEB_UP_RES_LIMIT_E2D_S
WITCH,
PERFENH_LTE_NCELL_FILTE_OPT_SWITCH,
PERFENH_U2L_PUNISH_BASED_ABS_FREQ_S
WITCH,
PERFENH_HE_BIT_OPT_AFTER_RELOC_IN_SW
ITCH,
PERFENH_HHO_RELOC_OUT_WITH_MR_SWIT
CH,
PERFENH_CS_P2D_TRIG_SERVICE_U2L_SWITC
H,
PERFENH_RB_RECFG_TRIG_SERVICE_U2L_SW
ITCH,
PERFENH_PERMIT_U2L_ONLY_UE_FROM_L_S
WITCH,
PERFENH_DTXDRX_ENABLEDELAY_CFGOPT_
SWITCH,
PERFENH_MCDRD_FAIL_PENALTY_OPT_SWIT
CH,
PERFENH_HSDPA_SPI_WEIGHT_UPDATE_SWIT
CH
Unit: None
Actual Value Range:
PERFENH_RCS_PS_DL_ON_DCH_SWITCH,
PERFENH_HSUPA_CAP_CHG_HRETRY_LMT_S
WITCH,
PERFENH_MC_OPT_AFTER_RETRANS_CHG_S
WITCH,
PERFENH_CSOVERH_H2D_RBID_CHG_SWITCH
,
PERFENH_RRC_DRD_FAILED_RED_GSM_SWIT
CH,
PERFENH_IRAT_COV_HO_NCELL_PRE_SWITC
H, PERFENH_LTE_NCELL_SEL_OPT_SWITCH,
PERFENH_GSM_NCELL_SEL_OPT_SWITCH,
PERFENH_U2L_REDIR_BASED_FREQ_OPT_SWI
TCH,
PERFENH_ICMP_ACCELERATOR_OPT_SWITCH
, PERFENH_MULTI_PS_DCCC_SWITCH,
PERFENH_CHL_CHG_FAIL_MC_OLPC_OPT_SW
ITCH,
PERFENH_SET2MBR_ALLOW_D2F_SWITCH,
PERFENH_RAB_REL_WITH_PS_D2F_OPT_SWIT
CH,
PERFENH_DRNC_CU_WITHOUT_EXTCELL_SW
ITCH,
PERFENH_HO_NODEB_UP_RES_LIMIT_E2D_S
WITCH,
PERFENH_LTE_NCELL_FILTE_OPT_SWITCH,
PERFENH_U2L_PUNISH_BASED_ABS_FREQ_S
WITCH,
PERFENH_HE_BIT_OPT_AFTER_RELOC_IN_SW
ITCH,
PERFENH_HHO_RELOC_OUT_WITH_MR_SWIT
CH,
PERFENH_CS_P2D_TRIG_SERVICE_U2L_SWITC
H,
PERFENH_RB_RECFG_TRIG_SERVICE_U2L_SW
ITCH,
PERFENH_PERMIT_U2L_ONLY_UE_FROM_L_S
WITCH,
PERFENH_DTXDRX_ENABLEDELAY_CFGOPT_
SWITCH,
PERFENH_MCDRD_FAIL_PENALTY_OPT_SWIT
CH,
PERFENH_HSDPA_SPI_WEIGHT_UPDATE_SWIT
CH
g this switch is turned on, the RNC filters out the list for
Connect measured neighboring LTE cells according to the
ion Re- RNC-level parameters, cell capability, and UE
establish capabilities in handovers and redirections to the LTE
ment network. When this switch is turned off, the RNC
(DSCR) does not filter out the list for measured neighboring
Inter- LTE cells.
RAT 8. PERFENH_GSM_NCELL_SEL_OPT_SWITCH:
Handov Scope for matching the neighboring cells in
er Based measurement reports during handovers to GSM cells
on Load when there are multiple cells in the active set and the
HO_MC_NCELL_COMBINE_SWITCH switch is
turned on. In case of neighboring combination, when
this switch is turned on, the RNC matches the
neighboring cells in measurement reports with
neighboring cells of all cells in the current active set.
When this switch is turned off, the RNC matches the
neighboring cells in measurement reports only with
the best cell's neighboring cells.
9.
PERFENH_U2L_REDIR_BASED_FREQ_OPT_SWI
TCH: Whether to select the best target frequency
during a frequency-based redirection from UMTS to
LTE. When this switch is turned on, the selected target
frequency is used as the best frequency if the
measurement report contains multiple neighboring
cells that work at the same frequency.
10.
PERFENH_ICMP_ACCELERATOR_OPT_SWITCH
: Switch for the enhanced algorithm of accelerating
the rate for responding to control messages. This
parameter is a professional parameter and therefore
you must configure this parameter under the
instruction of Huawei technical support.For
RTT(round-trip time) tests, the recommended value is
ON. In other scenarios, the recommended value is
OFF.
11. PERFENH_MULTI_PS_DCCC_SWITCH:
Whether to allocate the RLC parameters
corresponding to the 2 ms TTI to the services that are
not reconfigured during the reconfiguration procedure
and have a data rate higher than 2048 kbit/s. The 2048
kbit/s is the maximum data rate supported by the 10
ms TTI. When this switch is turned on, the RNC
allocates such services the RLC parameters
corresponding to the 2 ms TTI. When this switch is
turned off. The RNC does not include the new SPI
weight adjustment factor in the Radio Link
Reconfiguration Prepare message.
GUI Value Range:
PERFENH_RCS_PS_DL_ON_DCH_SWITCH,
PERFENH_HSUPA_CAP_CHG_HRETRY_LMT_S
WITCH,
PERFENH_MC_OPT_AFTER_RETRANS_CHG_S
WITCH,
PERFENH_CSOVERH_H2D_RBID_CHG_SWITCH
,
PERFENH_RRC_DRD_FAILED_RED_GSM_SWIT
CH,
PERFENH_IRAT_COV_HO_NCELL_PRE_SWITC
H, PERFENH_LTE_NCELL_SEL_OPT_SWITCH,
PERFENH_GSM_NCELL_SEL_OPT_SWITCH,
PERFENH_U2L_REDIR_BASED_FREQ_OPT_SWI
TCH,
PERFENH_ICMP_ACCELERATOR_OPT_SWITCH
, PERFENH_MULTI_PS_DCCC_SWITCH,
PERFENH_CHL_CHG_FAIL_MC_OLPC_OPT_SW
ITCH,
PERFENH_SET2MBR_ALLOW_D2F_SWITCH,
PERFENH_RAB_REL_WITH_PS_D2F_OPT_SWIT
CH,
PERFENH_DRNC_CU_WITHOUT_EXTCELL_SW
ITCH,
PERFENH_HO_NODEB_UP_RES_LIMIT_E2D_S
WITCH,
PERFENH_LTE_NCELL_FILTE_OPT_SWITCH,
PERFENH_U2L_PUNISH_BASED_ABS_FREQ_S
WITCH,
PERFENH_HE_BIT_OPT_AFTER_RELOC_IN_SW
ITCH,
PERFENH_HHO_RELOC_OUT_WITH_MR_SWIT
CH,
PERFENH_CS_P2D_TRIG_SERVICE_U2L_SWITC
H,
PERFENH_RB_RECFG_TRIG_SERVICE_U2L_SW
ITCH,
PERFENH_PERMIT_U2L_ONLY_UE_FROM_L_S
WITCH,
PERFENH_DTXDRX_ENABLEDELAY_CFGOPT_
SWITCH,
PERFENH_MCDRD_FAIL_PENALTY_OPT_SWIT
CH,
PERFENH_HSDPA_SPI_WEIGHT_UPDATE_SWIT
CH
Unit: None
Actual Value Range:
PERFENH_RCS_PS_DL_ON_DCH_SWITCH,
PERFENH_HSUPA_CAP_CHG_HRETRY_LMT_S
WITCH,
PERFENH_MC_OPT_AFTER_RETRANS_CHG_S
WITCH,
PERFENH_CSOVERH_H2D_RBID_CHG_SWITCH
,
PERFENH_RRC_DRD_FAILED_RED_GSM_SWIT
CH,
PERFENH_IRAT_COV_HO_NCELL_PRE_SWITC
H, PERFENH_LTE_NCELL_SEL_OPT_SWITCH,
PERFENH_GSM_NCELL_SEL_OPT_SWITCH,
PERFENH_U2L_REDIR_BASED_FREQ_OPT_SWI
TCH,
PERFENH_ICMP_ACCELERATOR_OPT_SWITCH
, PERFENH_MULTI_PS_DCCC_SWITCH,
PERFENH_CHL_CHG_FAIL_MC_OLPC_OPT_SW
ITCH,
PERFENH_SET2MBR_ALLOW_D2F_SWITCH,
PERFENH_RAB_REL_WITH_PS_D2F_OPT_SWIT
CH,
PERFENH_DRNC_CU_WITHOUT_EXTCELL_SW
ITCH,
PERFENH_HO_NODEB_UP_RES_LIMIT_E2D_S
WITCH,
PERFENH_LTE_NCELL_FILTE_OPT_SWITCH,
PERFENH_U2L_PUNISH_BASED_ABS_FREQ_S
WITCH,
PERFENH_HE_BIT_OPT_AFTER_RELOC_IN_SW
ITCH,
PERFENH_HHO_RELOC_OUT_WITH_MR_SWIT
CH,
PERFENH_CS_P2D_TRIG_SERVICE_U2L_SWITC
H,
PERFENH_RB_RECFG_TRIG_SERVICE_U2L_SW
ITCH,
PERFENH_PERMIT_U2L_ONLY_UE_FROM_L_S
WITCH,
PERFENH_DTXDRX_ENABLEDELAY_CFGOPT_
SWITCH,
PERFENH_MCDRD_FAIL_PENALTY_OPT_SWIT
CH,
PERFENH_HSDPA_SPI_WEIGHT_UPDATE_SWIT
CH
WRFD- Fast
020129 Return
from
WRFD- UMTS
020302 to LTE
WRFD- 3G/2G
020303 Commo
WRFD- n Load
020304 Manage
ment
WRFD-
020305 Coverag
e Based
WRFD- PS
020306 Redirect
WRFD- ion from
0203080 UMTS
1 to LTE
Inter-
RAT
Handov
er Phase
2
HSUPA
Mobility
Manage
ment
Inter-
RAT
Handov
er Based
on DL
QoS
Mobility
Between
UMTS
and LTE
Phase 1
Intra
Frequen
cy Hard
Handov
er
PS
Service
Redirect
ion from
UMTS
to LTE
Inter
Frequen
cy Hard
Handov
er Based
on
Coverag
e
Inter-
RAT
Handov
er Based
on
Coverag
e
Inter
Frequen
cy Hard
Handov
er Based
on DL
QoS
Inter-
RAT
Handov
er Based
on
Service
Inter-
RAT
Handov
er Based
on Load
NACC(
Network
Assisted
Cell
Change)
WRFD- Fast
020129 Return
from
WRFD- UMTS
020302 to LTE
WRFD- 3G/2G
020303 Commo
WRFD- n Load
020304 Manage
ment
WRFD-
020305 Coverag
e Based
WRFD- PS
020306 Redirect
WRFD- ion from
0203080 UMTS
1 to LTE
Inter-
RAT
Handov
er Phase
2
HSUPA
Mobility
Manage
ment
Inter-
RAT
Handov
er Based
on DL
QoS
Mobility
Between
UMTS
and LTE
Phase 1
Intra
Frequen
cy Hard
Handov
er
PS
Service
Redirect
ion from
UMTS
to LTE
Inter
Frequen
cy Hard
Handov
er Based
on
Coverag
e
Inter-
RAT
Handov
er Based
on
Coverag
e
Inter
Frequen
cy Hard
Handov
er Based
on DL
QoS
Inter-
RAT
Handov
er Based
on
Service
Inter-
RAT
Handov
er Based
on Load
NACC(
Network
Assisted
Cell
Change)
HOPrio BSC690 ADD WRFD- Inter- Meaning: Priority of the neighboring cell as a target
0 U2GNC 020303 RAT cell for a handover. Value 0 indicates the highest
ELL Handov priority and value 7 indicates the lowest priority.
MOD er Based When this parameter takes effect, the RNC
U2GNC on preferentially selects the cell with the highest priority
ELL Coverag as the target cell. If two or more cells have the same
e priority, the RNC selects a target cell with the best
signal quality.
GUI Value Range: 0~7
Unit: None
Actual Value Range: 0~7
Default Value: 0
HOPrio BSC691 ADD WRFD- Inter- Meaning: Priority of the neighboring cell as a target
0 U2GNC 020303 RAT cell for a handover. Value 0 indicates the highest
ELL Handov priority and value 7 indicates the lowest priority.
MOD er Based When this parameter takes effect, the RNC
U2GNC on preferentially selects the cell with the highest priority
ELL Coverag as the target cell. If two or more cells have the same
e priority, the RNC selects a target cell with the best
signal quality.
GUI Value Range: 0~7
Unit: None
Actual Value Range: 0~7
Default Value: 0
RatCell BSC690 ADD WRFD- Inter- Meaning: Identifying the type of the inter-RAT cell
Type 0 UEXT2 020309 RAT NO_CAPABILITY indicates that the capacity of the
GCELL WRFD- Handov GSM cell remains unknown. It is not recommended to
MOD 020303 er Based set the cell type to NO_CAPABILITY. If the cell type
UEXT2 on DL is NO_CAPABILITY, the inter-RAT handover cannot
WRFD- QoS be triggered.
GCELL 020305
Inter- GUI Value Range: NO_CAPABILITY(Cell capability
WRFD- RAT unknown), GSM(GSM), GPRS(GPRS),
020306 Handov EDGE(EDGE)
er Based Unit: None
on
Coverag Actual Value Range: NO_CAPABILITY, GSM,
e GPRS, EDGE
RatCell BSC691 ADD WRFD- Inter- Meaning: Identifying the type of the inter-RAT cell
Type 0 UEXT2 020309 RAT NO_CAPABILITY indicates that the capacity of the
GCELL WRFD- Handov GSM cell remains unknown. It is not recommended to
MOD 020303 er Based set the cell type to NO_CAPABILITY. If the cell type
UEXT2 on DL is NO_CAPABILITY, the inter-RAT handover cannot
WRFD- QoS be triggered.
GCELL 020305
Inter- GUI Value Range: NO_CAPABILITY(Cell capability
WRFD- RAT unknown), GSM(GSM), GPRS(GPRS),
020306 Handov EDGE(EDGE)
er Based Unit: None
on
Coverag Actual Value Range: NO_CAPABILITY, GSM,
e GPRS, EDGE
Req2GC BSC690 ADD WRFD- Inter- Meaning: Minimum capability of the 2G cell required
ap 0 UTYPR 020309 RAT for inter-RAT handover from 3G network to 2G
ABBAS WRFD- Handov network. If the 2G cell is not capable, the handover
IC 020303 er Based will not be performed. An EDGE cell is more capable
MOD on DL of supporting PS services than a GPRS cell, whereas a
WRFD- QoS GPRS cell more capable than a GSM cell.
UTYPR 0203080
ABBAS 2 Inter- GUI Value Range: GSM, GPRS, EDGE
IC RAT Unit: None
WRFD- Handov
020305 er Based Actual Value Range: GSM, GPRS, EDGE
WRFD- on Default Value: None
020306 Coverag
e
PS
Handov
er
Between
UMTS
and
GPRS
Inter-
RAT
Handov
er Based
on
Service
Inter-
RAT
Handov
er Based
on Load
Req2GC BSC691 ADD WRFD- Inter- Meaning: Minimum capability of the 2G cell required
ap 0 UTYPR 020309 RAT for inter-RAT handover from 3G network to 2G
ABBAS WRFD- Handov network. If the 2G cell is not capable, the handover
IC 020303 er Based will not be performed. An EDGE cell is more capable
MOD on DL of supporting PS services than a GPRS cell, whereas a
WRFD- QoS GPRS cell more capable than a GSM cell.
UTYPR 0203080
ABBAS 2 Inter- GUI Value Range: GSM, GPRS, EDGE
IC RAT Unit: None
WRFD- Handov
020305 er Based Actual Value Range: GSM, GPRS, EDGE
WRFD- on Default Value: None
020306 Coverag
e
PS
Handov
er
Between
UMTS
and
GPRS
Inter-
RAT
Handov
er Based
on
Service
Inter-
RAT
Handov
er Based
on Load
PS - HO_TO_GSM_SHALL_NOT_BE_PERFORM:
Handov Handover to the 2G network is not performed even if
er 3G signals are weak but 2G signals are strong.
Between GUI Value Range:
UMTS HO_TO_GSM_SHOULD_BE_PERFORM,
and HO_TO_GSM_SHOULD_NOT_BE_PERFORM,
GPRS HO_TO_GSM_SHALL_NOT_BE_PERFORM
Inter- Unit: None
RAT Actual Value Range:
Handov HO_TO_GSM_SHOULD_BE_PERFORM,
er Based HO_TO_GSM_SHOULD_NOT_BE_PERFORM,
on HO_TO_GSM_SHALL_NOT_BE_PERFORM
Service
Default Value: None
Inter-
RAT
Handov
er Based
on Load
PS - HO_TO_GSM_SHALL_NOT_BE_PERFORM:
Handov Handover to the 2G network is not performed even if
er 3G signals are weak but 2G signals are strong.
Between GUI Value Range:
UMTS HO_TO_GSM_SHOULD_BE_PERFORM,
and HO_TO_GSM_SHOULD_NOT_BE_PERFORM,
GPRS HO_TO_GSM_SHALL_NOT_BE_PERFORM
Inter- Unit: None
RAT Actual Value Range:
Handov HO_TO_GSM_SHOULD_BE_PERFORM,
er Based HO_TO_GSM_SHOULD_NOT_BE_PERFORM,
on HO_TO_GSM_SHALL_NOT_BE_PERFORM
Service
Default Value: None
Inter-
RAT
Handov
er Based
on Load
SuppPS BSC690 ADD WRFD- PS Meaning: Identifying whether the inter-RAT cell
HOFlag 0 UEXT2 0203080 Handov supports PS HO. TRUE indicates that the inter-RAT
GCELL 2 er cell is able to perform the handover procedure with
MOD Between relocation. FALSE indicates that the cell is unable to
UEXT2 UMTS do so.
GCELL and GUI Value Range: FALSE, TRUE
GPRS
Unit: None
Actual Value Range: FALSE, TRUE
Default Value: False
SuppPS BSC691 ADD WRFD- PS Meaning: Identifying whether the inter-RAT cell
HOFlag 0 UEXT2 0203080 Handov supports PS HO. TRUE indicates that the inter-RAT
GCELL 2 er cell is able to perform the handover procedure with
MOD Between relocation. FALSE indicates that the cell is unable to
UEXT2 UMTS do so.
GCELL and GUI Value Range: FALSE, TRUE
GPRS
Unit: None
Actual Value Range: FALSE, TRUE
Default Value: False
IUR_RL_REEST_SWITCH,
RB_SETUP_RL_REEST_SWITCH,
RRC_CONN_SETUP_OPT_SWITCH,
TCP_ACK_ACCELERATOR_SWITCH,
RRC_CELLFACH_TRB_RESET_TO_F2D_SWITC
H, SEND_MSG_NULL_SWITCH,
FD_PCH_IUR_CS_OPT_SWITCH,
CELLUPT_T314_T315_TIMEOUT_OPT_SWITCH,
CS_HHO_ASYNC_CTRL_SWITCH,
PS_HHO_ASYNC_CTRL_SWITCH,
IUR_HHO_ASYNC_CTRL_SWITCH,
R8_UE_SEL_DPUE_SWITCH,
F2P_DATATRANS_OPTIMIZE_SWITCH,
IRATHO_HOCANCEL_RL_REEST_SWITCH,
TRB_RESET_RL_REEST_SWITCH,
RB_REL_RL_REEST_SWITCH,
RB_SETUP_ENHANCE_RL_REEST_SWITCH,
RAB_SETUPMOD_CNT_FIX_SWITCH,
PCH_UE_RLC_UNRECOVERABLEER-
ROR_SWITCH,
FAST_RETURN_LTE_BY_CELL_SELECT_SWITC
H, UL_DUAL_MODE_UE_D2P_OR_D2I_SWITCH,
PHYCHRECFG_ENH_RL_REEST_SWITCH,
RBRECFG_ENH_RL_REEST_SWITCH,
SMC_STOP_RLC_SWITCH,
GTP_SN_IN_RAB_REL_INIT_BY_UTRAN_SWIT
CH, CMP_IU_QOS_GTP_PDU_SN_SWITCH,
DL_TRB_RESET_BUFF_SWITCH,
RRC_CELLFACH_DL_TRB_RESET_TO_F2D_SWI
TCH,
RAB_ASS_MOD_TNL_ADDR_SUP_SWITCH
Unit: None
Actual Value Range:
PS_F2D_OVERLAP_CELLUPT_SWITCH,
AMR_HHO_FAIL_ROLLBACK_SWITCH,
PHY_RECFG_REEST_SWITCH,
IUR_RL_REEST_SWITCH,
RB_SETUP_RL_REEST_SWITCH,
RRC_CONN_SETUP_OPT_SWITCH,
TCP_ACK_ACCELERATOR_SWITCH,
RRC_CELLFACH_TRB_RESET_TO_F2D_SWITC
H, SEND_MSG_NULL_SWITCH,
FD_PCH_IUR_CS_OPT_SWITCH,
CELLUPT_T314_T315_TIMEOUT_OPT_SWITCH,
CS_HHO_ASYNC_CTRL_SWITCH,
PS_HHO_ASYNC_CTRL_SWITCH,
IUR_HHO_ASYNC_CTRL_SWITCH,
R8_UE_SEL_DPUE_SWITCH,
F2P_DATATRANS_OPTIMIZE_SWITCH,
IRATHO_HOCANCEL_RL_REEST_SWITCH,
TRB_RESET_RL_REEST_SWITCH,
RB_REL_RL_REEST_SWITCH,
RB_SETUP_ENHANCE_RL_REEST_SWITCH,
RAB_SETUPMOD_CNT_FIX_SWITCH,
PCH_UE_RLC_UNRECOVERABLEER-
ROR_SWITCH,
FAST_RETURN_LTE_BY_CELL_SELECT_SWITC
H, UL_DUAL_MODE_UE_D2P_OR_D2I_SWITCH,
PHYCHRECFG_ENH_RL_REEST_SWITCH,
RBRECFG_ENH_RL_REEST_SWITCH,
SMC_STOP_RLC_SWITCH,
GTP_SN_IN_RAB_REL_INIT_BY_UTRAN_SWIT
CH,
CMP_IU_QOS_GTP_PDU_SN_SWITCH,
DL_TRB_RESET_BUFF_SWITCH,
RRC_CELLFACH_DL_TRB_RESET_TO_F2D_SWI
TCH,
RAB_ASS_MOD_TNL_ADDR_SUP_SWITCH
Default Value:
PS_F2D_OVERLAP_CELLUPT_SWITCH:
0,AMR_HHO_FAIL_ROLLBACK_SWITCH:
0,PHY_RECFG_REEST_SWITCH:
0,IUR_RL_REEST_SWITCH:
0,RB_SETUP_RL_REEST_SWITCH:
0,RRC_CONN_SETUP_OPT_SWITCH:
0,TCP_ACK_ACCELERATOR_SWITCH:
0,RRC_CELLFACH_TRB_RESET_TO_F2D_SWIT
CH:0,SEND_MSG_NULL_SWITCH:
0,FD_PCH_IUR_CS_OPT_SWITCH:
0,CELLUPT_T314_T315_TIMEOUT_OPT_SWITC
H:0,CS_HHO_ASYNC_CTRL_SWITCH:
0,PS_HHO_ASYNC_CTRL_SWITCH:
0,IUR_HHO_ASYNC_CTRL_SWITCH:
0,R8_UE_SEL_DPUE_SWITCH:
0,F2P_DATATRANS_OPTIMIZE_SWITCH:
0,IRATHO_HOCANCEL_RL_REEST_SWITCH:
0,TRB_RESET_RL_REEST_SWITCH:
0,RB_REL_RL_REEST_SWITCH:
0,RB_SETUP_ENHANCE_RL_REEST_SWITCH:
0,RAB_SETUPMOD_CNT_FIX_SWITCH:
0,PCH_UE_RLC_UNRECOVERABLEER-
ROR_SWITCH:
0,FAST_RETURN_LTE_BY_CELL_SELECT_SWIT
CH:
CS_HHO_ASYNC_CTRL_SWITCH,
PS_HHO_ASYNC_CTRL_SWITCH,
IUR_HHO_ASYNC_CTRL_SWITCH,
F2P_DATATRANS_OPTIMIZE_SWITCH,
IRATHO_HOCANCEL_RL_REEST_SWITCH,
TRB_RESET_RL_REEST_SWITCH,
RB_REL_RL_REEST_SWITCH,
RB_SETUP_ENHANCE_RL_REEST_SWITCH,
RAB_SETUPMOD_CNT_FIX_SWITCH,
PCH_UE_RLC_UNRECOVERABLEER-
ROR_SWITCH,
FAST_RETURN_LTE_BY_CELL_SELECT_SWITC
H, UL_DUAL_MODE_UE_D2P_OR_D2I_SWITCH,
PHYCHRECFG_ENH_RL_REEST_SWITCH,
RBRECFG_ENH_RL_REEST_SWITCH,
SMC_STOP_RLC_SWITCH,
GTP_SN_IN_RAB_REL_INIT_BY_UTRAN_SWIT
CH, CMP_IU_QOS_GTP_PDU_SN_SWITCH,
DL_TRB_RESET_BUFF_SWITCH,
RRC_CELLFACH_DL_TRB_RESET_TO_F2D_SWI
TCH,
RAB_ASS_MOD_TNL_ADDR_SUP_SWITCH
Unit: None
Actual Value Range:
PS_F2D_OVERLAP_CELLUPT_SWITCH,
AMR_HHO_FAIL_ROLLBACK_SWITCH,
PHY_RECFG_REEST_SWITCH,
IUR_RL_REEST_SWITCH,
RB_SETUP_RL_REEST_SWITCH,
RRC_CONN_SETUP_OPT_SWITCH,
TCP_ACK_ACCELERATOR_SWITCH,
RRC_CELLFACH_TRB_RESET_TO_F2D_SWITC
H, SEND_MSG_NULL_SWITCH,
FD_PCH_IUR_CS_OPT_SWITCH,
CELLUPT_T314_T315_TIMEOUT_OPT_SWITCH,
CS_HHO_ASYNC_CTRL_SWITCH,
PS_HHO_ASYNC_CTRL_SWITCH,
IUR_HHO_ASYNC_CTRL_SWITCH,
F2P_DATATRANS_OPTIMIZE_SWITCH,
IRATHO_HOCANCEL_RL_REEST_SWITCH,
TRB_RESET_RL_REEST_SWITCH,
RB_REL_RL_REEST_SWITCH,
RB_SETUP_ENHANCE_RL_REEST_SWITCH,
RAB_SETUPMOD_CNT_FIX_SWITCH,
PCH_UE_RLC_UNRECOVERABLEER-
ROR_SWITCH,
FAST_RETURN_LTE_BY_CELL_SELECT_SWITC
H, UL_DUAL_MODE_UE_D2P_OR_D2I_SWITCH,
PHYCHRECFG_ENH_RL_REEST_SWITCH,
RBRECFG_ENH_RL_REEST_SWITCH,
SMC_STOP_RLC_SWITCH,
GTP_SN_IN_RAB_REL_INIT_BY_UTRAN_SWIT
CH,
CMP_IU_QOS_GTP_PDU_SN_SWITCH,
DL_TRB_RESET_BUFF_SWITCH,
RRC_CELLFACH_DL_TRB_RESET_TO_F2D_SWI
TCH,
RAB_ASS_MOD_TNL_ADDR_SUP_SWITCH
Default Value:
PS_F2D_OVERLAP_CELLUPT_SWITCH:
0,AMR_HHO_FAIL_ROLLBACK_SWITCH:
0,PHY_RECFG_REEST_SWITCH:
0,IUR_RL_REEST_SWITCH:
0,RB_SETUP_RL_REEST_SWITCH:
0,RRC_CONN_SETUP_OPT_SWITCH:
0,TCP_ACK_ACCELERATOR_SWITCH:
0,RRC_CELLFACH_TRB_RESET_TO_F2D_SWIT
CH:0,SEND_MSG_NULL_SWITCH:
0,FD_PCH_IUR_CS_OPT_SWITCH:
0,CELLUPT_T314_T315_TIMEOUT_OPT_SWITC
H:0,CS_HHO_ASYNC_CTRL_SWITCH:
0,PS_HHO_ASYNC_CTRL_SWITCH:
0,IUR_HHO_ASYNC_CTRL_SWITCH:
0,F2P_DATATRANS_OPTIMIZE_SWITCH:
0,IRATHO_HOCANCEL_RL_REEST_SWITCH:
0,TRB_RESET_RL_REEST_SWITCH:
0,RB_REL_RL_REEST_SWITCH:
0,RB_SETUP_ENHANCE_RL_REEST_SWITCH:
0,RAB_SETUPMOD_CNT_FIX_SWITCH:
0,PCH_UE_RLC_UNRECOVERABLEER-
ROR_SWITCH:
0,FAST_RETURN_LTE_BY_CELL_SELECT_SWIT
CH:
0,UL_DUAL_MODE_UE_D2P_OR_D2I_SWITCH:
0,PHYCHRECFG_ENH_RL_REEST_SWITCH:
0,RBRECFG_ENH_RL_REEST_SWITCH:
0,SMC_STOP_RLC_SWITCH:
1,GTP_SN_IN_RAB_REL_INIT_BY_UTRAN_SWI
TCH:1,CMP_IU_QOS_GTP_PDU_SN_SWITCH:
0,DL_TRB_RESET_BUFF_SWITCH:
0,RRC_CELLFACH_DL_TRB_RESET_TO_F2D_S
WITCH:
0,RAB_ASS_MOD_TNL_ADDR_SUP_SWITCH:1
Penalty BSC690 ADD WRFD- Inter- Meaning: Duration after which the coverage-based
TimerFo 0 UCELLI 020309 RAT inter-frequency handover, inter-frequency blind
rIFHoFa NTERF WRFD- Handov handover triggered by event 1F, or QoS-based inter-
il REQHO 020302 er Based frequency handover to a cell can be re-initiated after a
COV on DL failure of such handover to this cell due to the air
MOD QoS interface faults.
UCELLI Inter GUI Value Range: 0~65535
NTERF Frequen Unit: s
REQHO cy Hard
COV Handov Actual Value Range: 0~65535
er Based Default Value: 0
on
Coverag
e
Penalty BSC691 ADD WRFD- Inter- Meaning: Duration after which the coverage-based
TimerFo 0 UCELLI 020309 RAT inter-frequency handover, inter-frequency blind
rIFHoFa NTERF WRFD- Handov handover triggered by event 1F, or QoS-based inter-
il REQHO 020302 er Based frequency handover to a cell can be re-initiated after a
COV on DL failure of such handover to this cell due to the air
MOD QoS interface faults.
UCELLI Inter GUI Value Range: 0~65535
NTERF Frequen Unit: s
REQHO cy Hard
COV Handov Actual Value Range: 0~65535
er Based Default Value: 0
on
Coverag
e
IFHoFai BSC690 ADD WRFD- Inter- Meaning: Maximum number of consecutive handover
lNum 0 UCELLI 020309 RAT failures after a coverage-based inter-frequency
NTERF WRFD- Handov handover, inter-frequency blind handover triggered by
REQHO 020302 er Based event 1F, or QoS-based inter-frequency handover to a
COV on DL cell fails due to the air interface faults. When the
MOD QoS number of consecutive handover failures of a UE in a
UCELLI Inter call is greater than the value of this parameter, the
NTERF Frequen RNC penalizes the UE and the UE cannot initiate such
REQHO cy Hard inter-frequency handovers within the penalty period.
COV Handov GUI Value Range: 0~63
er Based Unit: None
on
Coverag Actual Value Range: 0~63
e Default Value: 3
IFHoFai BSC691 ADD WRFD- Inter- Meaning: Maximum number of consecutive handover
lNum 0 UCELLI 020309 RAT failures after a coverage-based inter-frequency
NTERF WRFD- Handov handover, inter-frequency blind handover triggered by
REQHO 020302 er Based event 1F, or QoS-based inter-frequency handover to a
COV on DL cell fails due to the air interface faults. When the
MOD QoS number of consecutive handover failures of a UE in a
UCELLI Inter call is greater than the value of this parameter, the
NTERF Frequen RNC penalizes the UE and the UE cannot initiate such
REQHO cy Hard inter-frequency handovers within the penalty period.
COV Handov GUI Value Range: 0~63
er Based Unit: None
on
Coverag Actual Value Range: 0~63
e Default Value: 3
UEPenal BSC690 ADD WRFD- Inter- Meaning: Duration after which the coverage-based
tyTimer 0 UCELLI 020309 RAT inter-frequency handover, inter-frequency blind
ForIFHo NTERF WRFD- Handov handover triggered by event 1F, or QoS-based inter-
Fail REQHO 020302 er Based frequency handover to a cell can be re-initiated after a
COV on DL failure of such handover to this cell due to the air
MOD QoS interface faults.
UCELLI Inter GUI Value Range: 0~65535
NTERF Frequen Unit: s
REQHO cy Hard
COV Handov Actual Value Range: 0~65535
er Based Default Value: 0
on
Coverag
e
UEPenal BSC691 ADD WRFD- Inter- Meaning: Duration after which the coverage-based
tyTimer 0 UCELLI 020309 RAT inter-frequency handover, inter-frequency blind
ForIFHo NTERF WRFD- Handov handover triggered by event 1F, or QoS-based inter-
Fail REQHO 020302 er Based frequency handover to a cell can be re-initiated after a
COV on DL failure of such handover to this cell due to the air
MOD QoS interface faults.
UCELLI Inter GUI Value Range: 0~65535
NTERF Frequen Unit: s
REQHO cy Hard
COV Handov Actual Value Range: 0~65535
er Based Default Value: 0
on
Coverag
e
20. PERFENH_OLPC_BLER_COEF_ADJUST:
Switch for adjusting the BLER coefficient specific to
CS services based on the best cell's uplink load status.
When this switch is turned on, the outer loop power
control algorithm uses the target BLER set by the
OMU board if the best cell's uplink load status is LDR
or OLC. If the status is neither LDR nor OLC, this
algorithm uses this target BLER after being divided by
five.
21.
PERFENH_EMG_AGPS_MC_DELAY_SWITCH:
Whether to enable the function of delaying the
sending of an RRC_MEAS_CTRL message
containing AGPS information when an emergency call
is made. When this switch is turned on, the RNC
delays the sending of this message until the
emergency call is successfully set up. When this
switch is turned off, the RNC sends this message upon
receiving a LOCATION_REPORTING_CONTROL
message from the CN.
22.
PERFENH_MULTI_RLS_CQI_PARA_OPT_SWITC
H: Whether to enable a UE having multiple RLSs to
use the value of "CQIReF" and the value of
"CQIFbCk" that are for UEs having only one RLS.
The two parameters can be set by running the "SET
UHSDPCCH" and "ADD UCELLHSDPCCH"
commands. When this switch is turned off, the UE
does not use the values of the two parameters that are
for UEs having only one RLS. When this switch is
turned on, the UE uses the values of the two
parameters that are for UEs having only one RLS.
23.
PERFENH_RELOC_IE_CALCTIMEFORCIP_SWIT
CH: Whether to enable a RELOCATION REQUIRED
message to contain the IE calculationTimeForCipher-
ing.
When this switch is turned on, static relocation request
messages contain the IE calculationTimeForCipher-
ing.
24.
PERFENH_IS_TIMEOUT_TRIG_DRD_SWITCH:
Whether to trigger the DRD procedure and channel
switchover from E-DCH or HS-DSCH to DCH when
messages transmitted over the Uu and Iub interfaces
do not arrive in time. When this switch is turned off,
the DRD procedure and channel switchover from E-
29.
PERFENH_L2U_CSFB_COMMCALL_SWITCH:
Whether to preferentially admit PS services of UEs
involved in LTE-to-UMTS CS fallback. When this
switch is turned on: If a UE involved in a LTE-to-
UMTS CS fallback is processing a non-real-time PS
service, the channel type and initial data rate for the
PS service are determined by the
"NRTInitRateforL2U" parameter in the "SET UFRC"
command during service admission. If the UE is
processing a real-time PS service, the UE follows the
standard access procedure. If the access attempt fails
and the "PreemptAlgoSwitch" in the "SET
UQUEUEPREEMPT" command is turned on, the UE
can preempt radio resources of existing UEs in the
UMTS cell. When this switch is turned off, the UE
follows the standard access procedure for the PS
service.
30.
PERFENH_DLBLINDDETECT_WHEN_ONLYSRB
ONDCH: This parameter controls whether to enable
blind detection for the HSDPA user-associated single-
signaling R99 channel. When the switch specified by
this parameter is turned on, blind detection is enabled.
31.
PERFENH_DLBLINDDETECT_WHEN_SRBAMR
ONDCH: This parameter controls whether to enable
blind detection for the HSDPA user-associated AMR
R99 channel. When the switch specified by this
parameter is turned on, blind detection is enabled if
the HSDPA service has been set up and there are
signaling and AMR traffic carried on the R99 channel.
32.
PERFENH_R6_HSUPA_TTI_10MSTO2MS_LIMIT:
Whether to allow R6 UEs to switch from HSUPA 10
ms to 2 ms TTI. When the switch is turned on, this
switching is not allowed for R6 UEs. When the switch
is turned off, this limit does not work.
This parameter is an advanced parameter. To modify
this parameter, contact Huawei Customer Service
Center for technical support.
GUI Value Range:
PERFENH_AMR_SPEC_BR_SWITCH,
PERFENH_AMR_TMPLT_SWITCH,
PERFENH_SRB_TMPLT_SWITCH,
PERFENH_OLPC_TMPLT_SWITCH,
PERFENH_AMR_SP_TMPLT_SWITCH,
PERFENH_INTRAFREQ_MC_TMPLT_SWITCH,
PERFENH_INTERRAT_PENALTY_50_SWITCH,
PERFENH_SRB_OVER_HSUPA_TTI10_SWITCH,
PERFENH_HSUPA_TTI2_ENHANCE_SWITCH,
PERFENH_UU_P2D_CUC_OPT_SWITCH,
PERFENH_RL_RECFG_SIR_CONSIDER_SWITCH
, PERFENH_RRC_REDIR_PROTECT_SWITCH,
PERFENH_H2F_OPT_SWITCH,
PERFENH_PSTRAFFIC_P2H_SWITCH,
PERFENH_VIP_USER_PCHR_MR_SWITCH,
PERFENH_TX_INTERRUPT_AFT_TRIG_SWITCH
,
PERFENH_CELL_HSUPA_CAP_CHANGE_OPT_S
WITCH,
PERFENH_HSUPA_TTI_RECFG_PROC_OPT_SWI
TCH,
PERFENH_DOWNLOAD_ENHANCE_SWITCH,
PERFENH_OLPC_BLER_COEF_ADJUST,
PERFENH_EMG_AGPS_MC_DELAY_SWITCH,
PERFENH_MULTI_RLS_CQI_PARA_OPT_SWITC
H,
PERFENH_RELOC_IE_CALCTIMEFORCIP_SWIT
CH,
PERFENH_IS_TIMEOUT_TRIG_DRD_SWITCH,
PERFENH_CELL_CACLOAD_BROADCAST_AM
END,
PERFENH_MBDR_TARCELLSEL_OPT_SWITCH,
PERFENH_RRC_DRD_PREADMISSION_SWITCH
, PERFENH_RRC_WEAK_REDIR_SWITCH,
PERFENH_L2U_CSFB_COMMCALL_SWITCH,
PERFENH_DLBLINDDETECT_WHEN_ONLYSRB
ONDCH,
PERFENH_DLBLINDDETECT_WHEN_SRBAMR
ONDCH,
PERFENH_R6_HSUPA_TTI_10MSTO2MS_LIMIT
Unit: None
Actual Value Range:
PERFENH_AMR_SPEC_BR_SWITCH,
PERFENH_AMR_TMPLT_SWITCH,
PERFENH_SRB_TMPLT_SWITCH,
PERFENH_OLPC_TMPLT_SWITCH,
PERFENH_AMR_SP_TMPLT_SWITCH,
PERFENH_INTRAFREQ_MC_TMPLT_SWITCH,
PERFENH_INTERRAT_PENALTY_50_SWITCH,
PERFENH_SRB_OVER_HSUPA_TTI10_SWITCH,
PERFENH_HSUPA_TTI2_ENHANCE_SWITCH,
PERFENH_UU_P2D_CUC_OPT_SWITCH,
PERFENH_RL_RECFG_SIR_CONSIDER_SWITCH
, PERFENH_RRC_REDIR_PROTECT_SWITCH,
PERFENH_H2F_OPT_SWITCH,
PERFENH_PSTRAFFIC_P2H_SWITCH,
PERFENH_VIP_USER_PCHR_MR_SWITCH,
PERFENH_TX_INTERRUPT_AFT_TRIG_SWITCH
,
PERFENH_CELL_HSUPA_CAP_CHANGE_OPT_S
WITCH,
PERFENH_HSUPA_TTI_RECFG_PROC_OPT_SWI
TCH,
PERFENH_DOWNLOAD_ENHANCE_SWITCH,
PERFENH_OLPC_BLER_COEF_ADJUST,
PERFENH_EMG_AGPS_MC_DELAY_SWITCH,
PERFENH_MULTI_RLS_CQI_PARA_OPT_SWITC
H,
PERFENH_RELOC_IE_CALCTIMEFORCIP_SWIT
CH,
PERFENH_IS_TIMEOUT_TRIG_DRD_SWITCH,
PERFENH_CELL_CACLOAD_BROADCAST_AM
END,
PERFENH_MBDR_TARCELLSEL_OPT_SWITCH,
PERFENH_RRC_DRD_PREADMISSION_SWITCH
,
PERFENH_RRC_WEAK_REDIR_SWITCH,
PERFENH_L2U_CSFB_COMMCALL_SWITCH,
PERFENH_DLBLINDDETECT_WHEN_ONLYSRB
ONDCH,
PERFENH_DLBLINDDETECT_WHEN_SRBAMR
ONDCH,
PERFENH_R6_HSUPA_TTI_10MSTO2MS_LIMIT
Default Value:
PERFENH_AMR_SPEC_BR_SWITCH:
1,PERFENH_AMR_TMPLT_SWITCH:
1,PERFENH_SRB_TMPLT_SWITCH:
1,PERFENH_OLPC_TMPLT_SWITCH:
1,PERFENH_AMR_SP_TMPLT_SWITCH:
1,PERFENH_INTRAFREQ_MC_TMPLT_SWITCH:
1,PERFENH_INTERRAT_PENALTY_50_SWITCH:
1,PERFENH_SRB_OVER_HSUPA_TTI10_SWITCH
:0,PERFENH_HSUPA_TTI2_ENHANCE_SWITCH:
0,PERFENH_UU_P2D_CUC_OPT_SWITCH:
0,PERFENH_RL_RECFG_SIR_CONSIDER_SWITC
H:1,PERFENH_RRC_REDIR_PROTECT_SWITCH:
0,PERFENH_H2F_OPT_SWITCH:
20. PERFENH_OLPC_BLER_COEF_ADJUST:
Switch for adjusting the BLER coefficient specific to
CS services based on the best cell's uplink load status.
When this switch is turned on, the outer loop power
control algorithm uses the target BLER set by the
OMU board if the best cell's uplink load status is LDR
or OLC. If the status is neither LDR nor OLC, this
algorithm uses this target BLER after being divided by
five.
21.
PERFENH_EMG_AGPS_MC_DELAY_SWITCH:
Whether to enable the function of delaying the
sending of an RRC_MEAS_CTRL message
containing AGPS information when an emergency call
is made. When this switch is turned on, the RNC
delays the sending of this message until the
emergency call is successfully set up. When this
switch is turned off, the RNC sends this message upon
receiving a LOCATION_REPORTING_CONTROL
message from the CN.
22.
PERFENH_MULTI_RLS_CQI_PARA_OPT_SWITC
H: Whether to enable a UE having multiple RLSs to
use the value of "CQIReF" and the value of
"CQIFbCk" that are for UEs having only one RLS.
The two parameters can be set by running the "SET
UHSDPCCH" and "ADD UCELLHSDPCCH"
commands. When this switch is turned off, the UE
does not use the values of the two parameters that are
for UEs having only one RLS. When this switch is
turned on, the UE uses the values of the two
parameters that are for UEs having only one RLS.
23.
PERFENH_RELOC_IE_CALCTIMEFORCIP_SWIT
CH: Whether to enable a RELOCATION REQUIRED
message to contain the IE calculationTimeForCipher-
ing.
When this switch is turned on, static relocation request
messages contain the IE calculationTimeForCipher-
ing.
24.
PERFENH_IS_TIMEOUT_TRIG_DRD_SWITCH:
Whether to trigger the DRD procedure and channel
switchover from E-DCH or HS-DSCH to DCH when
messages transmitted over the Uu and Iub interfaces
do not arrive in time. When this switch is turned off,
the DRD procedure and channel switchover from E-
29.
PERFENH_L2U_CSFB_COMMCALL_SWITCH:
Whether to preferentially admit PS services of UEs
involved in LTE-to-UMTS CS fallback. When this
switch is turned on: If a UE involved in a LTE-to-
UMTS CS fallback is processing a non-real-time PS
service, the channel type and initial data rate for the
PS service are determined by the
"NRTInitRateforL2U" parameter in the "SET UFRC"
command during service admission. If the UE is
processing a real-time PS service, the UE follows the
standard access procedure. If the access attempt fails
and the "PreemptAlgoSwitch" in the "SET
UQUEUEPREEMPT" command is turned on, the UE
can preempt radio resources of existing UEs in the
UMTS cell. When this switch is turned off, the UE
follows the standard access procedure for the PS
service.
30.
PERFENH_DLBLINDDETECT_WHEN_ONLYSRB
ONDCH: This parameter controls whether to enable
blind detection for the HSDPA user-associated single-
signaling R99 channel. When the switch specified by
this parameter is turned on, blind detection is enabled.
31.
PERFENH_DLBLINDDETECT_WHEN_SRBAMR
ONDCH: This parameter controls whether to enable
blind detection for the HSDPA user-associated AMR
R99 channel. When the switch specified by this
parameter is turned on, blind detection is enabled if
the HSDPA service has been set up and there are
signaling and AMR traffic carried on the R99 channel.
32.
PERFENH_R6_HSUPA_TTI_10MSTO2MS_LIMIT:
Whether to allow R6 UEs to switch from HSUPA 10
ms to 2 ms TTI. When the switch is turned on, this
switching is not allowed for R6 UEs. When the switch
is turned off, this limit does not work.
This parameter is an advanced parameter. To modify
this parameter, contact Huawei Customer Service
Center for technical support.
GUI Value Range:
PERFENH_AMR_SPEC_BR_SWITCH,
PERFENH_AMR_TMPLT_SWITCH,
PERFENH_SRB_TMPLT_SWITCH,
PERFENH_OLPC_TMPLT_SWITCH,
PERFENH_AMR_SP_TMPLT_SWITCH,
PERFENH_INTRAFREQ_MC_TMPLT_SWITCH,
PERFENH_INTERRAT_PENALTY_50_SWITCH,
PERFENH_SRB_OVER_HSUPA_TTI10_SWITCH,
PERFENH_HSUPA_TTI2_ENHANCE_SWITCH,
PERFENH_UU_P2D_CUC_OPT_SWITCH,
PERFENH_RL_RECFG_SIR_CONSIDER_SWITCH
, PERFENH_RRC_REDIR_PROTECT_SWITCH,
PERFENH_H2F_OPT_SWITCH,
PERFENH_PSTRAFFIC_P2H_SWITCH,
PERFENH_VIP_USER_PCHR_MR_SWITCH,
PERFENH_TX_INTERRUPT_AFT_TRIG_SWITCH
,
PERFENH_CELL_HSUPA_CAP_CHANGE_OPT_S
WITCH,
PERFENH_HSUPA_TTI_RECFG_PROC_OPT_SWI
TCH,
PERFENH_DOWNLOAD_ENHANCE_SWITCH,
PERFENH_OLPC_BLER_COEF_ADJUST,
PERFENH_EMG_AGPS_MC_DELAY_SWITCH,
PERFENH_MULTI_RLS_CQI_PARA_OPT_SWITC
H,
PERFENH_RELOC_IE_CALCTIMEFORCIP_SWIT
CH,
PERFENH_IS_TIMEOUT_TRIG_DRD_SWITCH,
PERFENH_CELL_CACLOAD_BROADCAST_AM
END,
PERFENH_MBDR_TARCELLSEL_OPT_SWITCH,
PERFENH_RRC_DRD_PREADMISSION_SWITCH
, PERFENH_RRC_WEAK_REDIR_SWITCH,
PERFENH_L2U_CSFB_COMMCALL_SWITCH,
PERFENH_DLBLINDDETECT_WHEN_ONLYSRB
ONDCH,
PERFENH_DLBLINDDETECT_WHEN_SRBAMR
ONDCH,
PERFENH_R6_HSUPA_TTI_10MSTO2MS_LIMIT
Unit: None
Actual Value Range:
PERFENH_AMR_SPEC_BR_SWITCH,
PERFENH_AMR_TMPLT_SWITCH,
PERFENH_SRB_TMPLT_SWITCH,
PERFENH_OLPC_TMPLT_SWITCH,
PERFENH_AMR_SP_TMPLT_SWITCH,
PERFENH_INTRAFREQ_MC_TMPLT_SWITCH,
PERFENH_INTERRAT_PENALTY_50_SWITCH,
PERFENH_SRB_OVER_HSUPA_TTI10_SWITCH,
PERFENH_HSUPA_TTI2_ENHANCE_SWITCH,
PERFENH_UU_P2D_CUC_OPT_SWITCH,
PERFENH_RL_RECFG_SIR_CONSIDER_SWITCH
, PERFENH_RRC_REDIR_PROTECT_SWITCH,
PERFENH_H2F_OPT_SWITCH,
PERFENH_PSTRAFFIC_P2H_SWITCH,
PERFENH_VIP_USER_PCHR_MR_SWITCH,
PERFENH_TX_INTERRUPT_AFT_TRIG_SWITCH
,
PERFENH_CELL_HSUPA_CAP_CHANGE_OPT_S
WITCH,
PERFENH_HSUPA_TTI_RECFG_PROC_OPT_SWI
TCH,
PERFENH_DOWNLOAD_ENHANCE_SWITCH,
PERFENH_OLPC_BLER_COEF_ADJUST,
PERFENH_EMG_AGPS_MC_DELAY_SWITCH,
PERFENH_MULTI_RLS_CQI_PARA_OPT_SWITC
H,
PERFENH_RELOC_IE_CALCTIMEFORCIP_SWIT
CH,
PERFENH_IS_TIMEOUT_TRIG_DRD_SWITCH,
PERFENH_CELL_CACLOAD_BROADCAST_AM
END,
PERFENH_MBDR_TARCELLSEL_OPT_SWITCH,
PERFENH_RRC_DRD_PREADMISSION_SWITCH
,
PERFENH_RRC_WEAK_REDIR_SWITCH,
PERFENH_L2U_CSFB_COMMCALL_SWITCH,
PERFENH_DLBLINDDETECT_WHEN_ONLYSRB
ONDCH,
PERFENH_DLBLINDDETECT_WHEN_SRBAMR
ONDCH,
PERFENH_R6_HSUPA_TTI_10MSTO2MS_LIMIT
Default Value:
PERFENH_AMR_SPEC_BR_SWITCH:
1,PERFENH_AMR_TMPLT_SWITCH:
1,PERFENH_SRB_TMPLT_SWITCH:
1,PERFENH_OLPC_TMPLT_SWITCH:
1,PERFENH_AMR_SP_TMPLT_SWITCH:
1,PERFENH_INTRAFREQ_MC_TMPLT_SWITCH:
1,PERFENH_INTERRAT_PENALTY_50_SWITCH:
1,PERFENH_SRB_OVER_HSUPA_TTI10_SWITCH
:0,PERFENH_HSUPA_TTI2_ENHANCE_SWITCH:
0,PERFENH_UU_P2D_CUC_OPT_SWITCH:
0,PERFENH_RL_RECFG_SIR_CONSIDER_SWITC
H:1,PERFENH_RRC_REDIR_PROTECT_SWITCH:
0,PERFENH_H2F_OPT_SWITCH:
BlindH BSC690 SET WRFD- Inter Meaning: The number of required measurement
OIntrafr 0 UINTR 020103 Frequen reports for triggering an inter-frequency blind
eqMRA AFREQ cy Load handover. If the number of intra-frequency
mount HO Balance measurement reports continuously reported by the UE
reaches or exceeds the number of intra-frequency
measurement reports for triggering a blind handover
("BlindHOIntrafreqMRAmount"), the RNC initiates a
blind handover. Measurements are terminated if the
UE reports a measurement report indicating that the
handover criteria are not met. In this case, the RNC
does not initiate a blind handover to the target cell.
GUI Value Range: D1, D2, D4, D8
Unit: None
Actual Value Range: 1, 2, 4, 8
Default Value: D2
BlindH BSC691 SET WRFD- Inter Meaning: The number of required measurement
OIntrafr 0 UINTR 020103 Frequen reports for triggering an inter-frequency blind
eqMRA AFREQ cy Load handover. If the number of intra-frequency
mount HO Balance measurement reports continuously reported by the UE
reaches or exceeds the number of intra-frequency
measurement reports for triggering a blind handover
("BlindHOIntrafreqMRAmount"), the RNC initiates a
blind handover. Measurements are terminated if the
UE reports a measurement report indicating that the
handover criteria are not met. In this case, the RNC
does not initiate a blind handover to the target cell.
GUI Value Range: D1, D2, D4, D8
Unit: None
Actual Value Range: 1, 2, 4, 8
Default Value: D2
BlindH BSC690 ADD WRFD- Macro Meaning: RSCP threshold for triggering blind
OQualit 0 UINTE 150201 & Micro handovers. If the RSCP value of the current cell
yConditi RFREQ WRFD- Co- exceeds the value of this parameter, the RNC initiates
on NCELL 150232 carrier a blind handover to switch the UE to the inter-
MOD Uplink frequency neighboring cell. This threshold applies to
UINTE Interfere load-balancing-based blind handovers, and directed
RFREQ nce retries from low-frequency-band cells to high-
NCELL Control frequency-band cells.
Multiba GUI Value Range: -115~-25
nd Unit: dBm
Direct
Retry Actual Value Range: -115~-25
Based Default Value: -92
on UE
Location
BlindH BSC691 ADD WRFD- Macro Meaning: RSCP threshold for triggering blind
OQualit 0 UINTE 150201 & Micro handovers. If the RSCP value of the current cell
yConditi RFREQ WRFD- Co- exceeds the value of this parameter, the RNC initiates
on NCELL 150232 carrier a blind handover to switch the UE to the inter-
MOD Uplink frequency neighboring cell. This threshold applies to
UINTE Interfere load-balancing-based blind handovers, and directed
RFREQ nce retries from low-frequency-band cells to high-
NCELL Control frequency-band cells.
Multiba GUI Value Range: -115~-25
nd Unit: dBm
Direct
Retry Actual Value Range: -115~-25
Based Default Value: -92
on UE
Location
TrigTim BSC690 ADD WRFD- Inter- Meaning: Time delay to trigger event 3C.
e3C 0 UCELLI 020305 RAT GUI Value Range: D0, D10, D20, D40, D60, D80,
NTERR WRFD- Handov D100, D120, D160, D200, D240, D320, D640,
ATHON 020306 er Based D1280, D2560, D5000
COV on
WRFD- Service Unit: ms
MOD 020402
UCELLI Inter- Actual Value Range: 0, 10, 20, 40, 60, 80, 100, 120,
NTERR RAT 160, 200, 240, 320, 640, 1280, 2560, 5000
ATHON Handov Default Value: D640
COV er Based
on Load
Measure
ment
Based
Direct
Retry
TrigTim BSC691 ADD WRFD- Inter- Meaning: Time delay to trigger event 3C.
e3C 0 UCELLI 020305 RAT GUI Value Range: D0, D10, D20, D40, D60, D80,
NTERR WRFD- Handov D100, D120, D160, D200, D240, D320, D640,
ATHON 020306 er Based D1280, D2560, D5000
COV on
WRFD- Service Unit: ms
MOD 020402
UCELLI Inter- Actual Value Range: 0, 10, 20, 40, 60, 80, 100, 120,
NTERR RAT 160, 200, 240, 320, 640, 1280, 2560, 5000
ATHON Handov Default Value: D640
COV er Based
on Load
Measure
ment
Based
Direct
Retry
InterRA BSC690 ADD WRFD- Inter- Meaning: Quality requirement for the cell of another
TNCov 0 UCELLI 020305 RAT RAT during inter-RAT CS handovers. If the quality of
HOCST NTERR WRFD- Handov the target frequency is higher than this threshold,
hd ATHON 020306 er Based event 3C is triggered. Value 0 indicates the value of
COV on this parameter is smaller than -110 dBm.
MOD Service GUI Value Range: 0~63
UCELLI Inter- Unit: dBm
NTERR RAT
ATHON Handov Actual Value Range: -110~-48(Actual value meets the
COV er Based condition: Actual Value = GUI Value - 111)
on Load Default Value: 21
InterRA BSC691 ADD WRFD- Inter- Meaning: Quality requirement for the cell of another
TNCov 0 UCELLI 020305 RAT RAT during inter-RAT CS handovers. If the quality of
HOCST NTERR WRFD- Handov the target frequency is higher than this threshold,
hd ATHON 020306 er Based event 3C is triggered. Value 0 indicates the value of
COV on this parameter is smaller than -110 dBm.
MOD Service GUI Value Range: 0~63
UCELLI Inter- Unit: dBm
NTERR RAT
ATHON Handov Actual Value Range: -110~-48(Actual value meets the
COV er Based condition: Actual Value = GUI Value - 111)
on Load Default Value: 21
Hystfor3 BSC690 ADD WRFD- Inter- Meaning: Hysteresis for event 3C.
C 0 UCELLI 020305 RAT GUI Value Range: 0~15
NTERR WRFD- Handov
ATHON er Based Unit: 0.5dB
020306
COV on Actual Value Range: 0~7.5
WRFD- Service
MOD 020402 Default Value: 0
UCELLI Inter-
NTERR RAT
ATHON Handov
COV er Based
on Load
Measure
ment
Based
Direct
Retry
Hystfor3 BSC691 ADD WRFD- Inter- Meaning: Hysteresis for event 3C.
C 0 UCELLI 020305 RAT GUI Value Range: 0~15
NTERR WRFD- Handov
ATHON er Based Unit: 0.5dB
020306
COV on Actual Value Range: 0~7.5
WRFD- Service
MOD 020402 Default Value: 0
UCELLI Inter-
NTERR RAT
ATHON Handov
COV er Based
on Load
Measure
ment
Based
Direct
Retry
CSHOO BSC690 ADD WRFD- Load Meaning: Threshold for 2G load for outgoing inter-
ut2Gloa 0 UCELLI 070004 Based RAT CS handovers. If the GSM load policy is used,
dThd NTERR WRFD- GSM that is, "NcovHoOn2GldInd" in the "SET
ATHON 020310 and UINTERRATHONCOV" command is set to ON, a
COV UMTS non-coverage-based handover from the 3G cell to the
WRFD- Handov 2G cell is stopped if the uplink or downlink
MOD 020305
UCELLI er normalized load carried in the relocation response
NTERR WRFD- Enhance message from the 2G network exceeds the value of
ATHON 020306 ment this parameter.
COV Based GUI Value Range: 0~100
on Iur-g
Unit: %
3G/2G
Commo Actual Value Range: 0~100
n Load Default Value: 80
Manage
ment
Inter-
RAT
Handov
er Based
on
Service
Inter-
RAT
Handov
er Based
on Load
CSHOO BSC691 ADD WRFD- Load Meaning: Threshold for 2G load for outgoing inter-
ut2Gloa 0 UCELLI 070004 Based RAT CS handovers. If the GSM load policy is used,
dThd NTERR WRFD- GSM that is, "NcovHoOn2GldInd" in the "SET
ATHON 020310 and UINTERRATHONCOV" command is set to ON, a
COV UMTS non-coverage-based handover from the 3G cell to the
WRFD- Handov 2G cell is stopped if the uplink or downlink
MOD 020305
UCELLI er normalized load carried in the relocation response
NTERR WRFD- Enhance message from the 2G network exceeds the value of
ATHON 020306 ment this parameter.
COV Based GUI Value Range: 0~100
on Iur-g
Unit: %
3G/2G
Commo Actual Value Range: 0~100
n Load Default Value: 80
Manage
ment
Inter-
RAT
Handov
er Based
on
Service
Inter-
RAT
Handov
er Based
on Load
PERFENH_DIFF_SERVICE_BASED_ON_SPI_WEI
GHT,
PERFENH_CS_RATE_CONTROL_WHEN_RETRIE
VE,
PERFENH_FORBID_FACH_MULRAB_INITRATE
_OPT,
PERFENH_DRNC_DF2U_FORBID_OPT_SWITCH
Unit: None
Actual Value Range:
PERFENH_CS_ONLY_MEAS_FAST_RETURN_S
WITCH,
PERFENH_CSPS_IRAT_HO_FAIL_RETRY_SWIT
CH,
PERFENH_SATELLITE_TRANS_CELL_SHO_OPT
,
PERFENH_2G_LOAD_JUDGE_OPT_SWITCH,
PERFENH_U2L_HO_REQ_WITH_UE_HIST_INFO
_SW,
PERFENH_FAST_RETURN_OPT_SWITCH,
PERFENH_BE_SYSHOIN_BITRATE_OPT_SWITC
H,
PERFENH_CPC_SINGHARQ_COEXIST_SWITCH,
PERFENH_P2D_UE_LOC_BASED_DRD_OPT_SW
ITCH,
PERFENH_4CHSDPA_MOBILITY_OPT_SWITCH,
PERFENH_CPC_AND_4CHSDPA_COEXIST_SWI
TCH,
PERFENH_FORBID_HIGHSPEED_PF2D_OPT_SW
ITCH,
PERFENH_DIFF_SERVICE_BASED_ON_SPI_WEI
GHT,
PERFENH_CS_RATE_CONTROL_WHEN_RETRIE
VE,
PERFENH_FORBID_FACH_MULRAB_INITRATE
_OPT,
PERFENH_DRNC_DF2U_FORBID_OPT_SWITCH
Default Value:
PERFENH_CS_ONLY_MEAS_FAST_RETURN_S
WITCH:0,
PERFENH_CSPS_IRAT_HO_FAIL_RETRY_SWIT
CH:0,
PERFENH_SATELLITE_TRANS_CELL_SHO_OPT
:0, PERFENH_2G_LOAD_JUDGE_OPT_SWITCH:
0,
PERFENH_U2L_HO_REQ_WITH_UE_HIST_INFO
_SW:0,
PERFENH_FAST_RETURN_OPT_SWITCH:0,
PERFENH_BE_SYSHOIN_BITRATE_OPT_SWITC
H:0,
PERFENH_CPC_SINGHARQ_COEXIST_SWITCH:
0,
PERFENH_P2D_UE_LOC_BASED_DRD_OPT_SW
ITCH:0,
PERFENH_4CHSDPA_MOBILITY_OPT_SWITCH:
0,
PERFENH_CPC_AND_4CHSDPA_COEXIST_SWI
TCH:0,
PERFENH_FORBID_HIGHSPEED_PF2D_OPT_SW
ITCH:0,
PERFENH_DIFF_SERVICE_BASED_ON_SPI_WEI
GHT:1,
PERFENH_CS_RATE_CONTROL_WHEN_RETRIE
VE:0,
PERFENH_FORBID_FACH_MULRAB_INITRATE
_OPT:0,
PERFENH_DRNC_DF2U_FORBID_OPT_SWITCH:
0
PERFENH_DIFF_SERVICE_BASED_ON_SPI_WEI
GHT,
PERFENH_CS_RATE_CONTROL_WHEN_RETRIE
VE,
PERFENH_FORBID_FACH_MULRAB_INITRATE
_OPT,
PERFENH_DRNC_DF2U_FORBID_OPT_SWITCH
Unit: None
Actual Value Range:
PERFENH_CS_ONLY_MEAS_FAST_RETURN_S
WITCH,
PERFENH_CSPS_IRAT_HO_FAIL_RETRY_SWIT
CH,
PERFENH_SATELLITE_TRANS_CELL_SHO_OPT
,
PERFENH_2G_LOAD_JUDGE_OPT_SWITCH,
PERFENH_U2L_HO_REQ_WITH_UE_HIST_INFO
_SW,
PERFENH_FAST_RETURN_OPT_SWITCH,
PERFENH_BE_SYSHOIN_BITRATE_OPT_SWITC
H,
PERFENH_CPC_SINGHARQ_COEXIST_SWITCH,
PERFENH_P2D_UE_LOC_BASED_DRD_OPT_SW
ITCH,
PERFENH_4CHSDPA_MOBILITY_OPT_SWITCH,
PERFENH_CPC_AND_4CHSDPA_COEXIST_SWI
TCH,
PERFENH_FORBID_HIGHSPEED_PF2D_OPT_SW
ITCH,
PERFENH_DIFF_SERVICE_BASED_ON_SPI_WEI
GHT,
PERFENH_CS_RATE_CONTROL_WHEN_RETRIE
VE,
PERFENH_FORBID_FACH_MULRAB_INITRATE
_OPT,
PERFENH_DRNC_DF2U_FORBID_OPT_SWITCH
Default Value:
PERFENH_CS_ONLY_MEAS_FAST_RETURN_S
WITCH:0,
PERFENH_CSPS_IRAT_HO_FAIL_RETRY_SWIT
CH:0,
PERFENH_SATELLITE_TRANS_CELL_SHO_OPT
:0, PERFENH_2G_LOAD_JUDGE_OPT_SWITCH:
0,
PERFENH_U2L_HO_REQ_WITH_UE_HIST_INFO
_SW:0,
PERFENH_FAST_RETURN_OPT_SWITCH:0,
PERFENH_BE_SYSHOIN_BITRATE_OPT_SWITC
H:0,
PERFENH_CPC_SINGHARQ_COEXIST_SWITCH:
0,
PERFENH_P2D_UE_LOC_BASED_DRD_OPT_SW
ITCH:0,
PERFENH_4CHSDPA_MOBILITY_OPT_SWITCH:
0,
PERFENH_CPC_AND_4CHSDPA_COEXIST_SWI
TCH:0,
PERFENH_FORBID_HIGHSPEED_PF2D_OPT_SW
ITCH:0,
PERFENH_DIFF_SERVICE_BASED_ON_SPI_WEI
GHT:1,
PERFENH_CS_RATE_CONTROL_WHEN_RETRIE
VE:0,
PERFENH_FORBID_FACH_MULRAB_INITRATE
_OPT:0,
PERFENH_DRNC_DF2U_FORBID_OPT_SWITCH:
0
RESERVED_SWITCH_13_BIT4,
RESERVED_SWITCH_13_BIT5,
RESERVED_SWITCH_13_BIT6,
RESERVED_SWITCH_13_BIT7,
RESERVED_SWITCH_13_BIT8,
RESERVED_SWITCH_13_BIT9,
RESERVED_SWITCH_13_BIT10,
RESERVED_SWITCH_13_BIT11,
RESERVED_SWITCH_13_BIT12,
RESERVED_SWITCH_13_BIT13,
RESERVED_SWITCH_13_BIT14,
RESERVED_SWITCH_13_BIT15,
RESERVED_SWITCH_13_BIT16,
RESERVED_SWITCH_13_BIT17,
RESERVED_SWITCH_13_BIT18,
RESERVED_SWITCH_13_BIT19,
RESERVED_SWITCH_13_BIT20,
RESERVED_SWITCH_13_BIT21,
RESERVED_SWITCH_13_BIT22,
RESERVED_SWITCH_13_BIT23,
RESERVED_SWITCH_13_BIT24,
RESERVED_SWITCH_13_BIT25,
RESERVED_SWITCH_13_BIT26,
RESERVED_SWITCH_13_BIT27,
RESERVED_SWITCH_13_BIT28,
RESERVED_SWITCH_13_BIT29,
RESERVED_SWITCH_13_BIT30,
RESERVED_SWITCH_13_BIT31,
RESERVED_SWITCH_13_BIT32
Default Value: RESERVED_SWITCH_13_BIT1:0,
RESERVED_SWITCH_13_BIT2:0,
RESERVED_SWITCH_13_BIT3:0,
RESERVED_SWITCH_13_BIT4:0,
RESERVED_SWITCH_13_BIT5:0,
RESERVED_SWITCH_13_BIT6:0,
RESERVED_SWITCH_13_BIT7:0,
RESERVED_SWITCH_13_BIT8:0,
RESERVED_SWITCH_13_BIT9:0,
RESERVED_SWITCH_13_BIT10:0,
RESERVED_SWITCH_13_BIT11:0,
RESERVED_SWITCH_13_BIT12:0,
RESERVED_SWITCH_13_BIT13:0,
RESERVED_SWITCH_13_BIT14:0,
RESERVED_SWITCH_13_BIT15:0,
RESERVED_SWITCH_13_BIT16:0,
RESERVED_SWITCH_13_BIT17:0,
RESERVED_SWITCH_13_BIT18:0,
RESERVED_SWITCH_13_BIT19:0,
RESERVED_SWITCH_13_BIT20:0,
RESERVED_SWITCH_13_BIT21:0,
RESERVED_SWITCH_13_BIT22:0,
RESERVED_SWITCH_13_BIT23:0,
RESERVED_SWITCH_13_BIT24:0,
RESERVED_SWITCH_13_BIT25:0,
RESERVED_SWITCH_13_BIT26:0,
RESERVED_SWITCH_13_BIT27:0,
RESERVED_SWITCH_13_BIT28:0,
RESERVED_SWITCH_13_BIT29:0,
RESERVED_SWITCH_13_BIT30:0,
RESERVED_SWITCH_13_BIT31:0,
RESERVED_SWITCH_13_BIT32:0
RESERVED_SWITCH_13_BIT4,
RESERVED_SWITCH_13_BIT5,
RESERVED_SWITCH_13_BIT6,
RESERVED_SWITCH_13_BIT7,
RESERVED_SWITCH_13_BIT8,
RESERVED_SWITCH_13_BIT9,
RESERVED_SWITCH_13_BIT10,
RESERVED_SWITCH_13_BIT11,
RESERVED_SWITCH_13_BIT12,
RESERVED_SWITCH_13_BIT13,
RESERVED_SWITCH_13_BIT14,
RESERVED_SWITCH_13_BIT15,
RESERVED_SWITCH_13_BIT16,
RESERVED_SWITCH_13_BIT17,
RESERVED_SWITCH_13_BIT18,
RESERVED_SWITCH_13_BIT19,
RESERVED_SWITCH_13_BIT20,
RESERVED_SWITCH_13_BIT21,
RESERVED_SWITCH_13_BIT22,
RESERVED_SWITCH_13_BIT23,
RESERVED_SWITCH_13_BIT24,
RESERVED_SWITCH_13_BIT25,
RESERVED_SWITCH_13_BIT26,
RESERVED_SWITCH_13_BIT27,
RESERVED_SWITCH_13_BIT28,
RESERVED_SWITCH_13_BIT29,
RESERVED_SWITCH_13_BIT30,
RESERVED_SWITCH_13_BIT31,
RESERVED_SWITCH_13_BIT32
Default Value: RESERVED_SWITCH_13_BIT1:0,
RESERVED_SWITCH_13_BIT2:0,
RESERVED_SWITCH_13_BIT3:0,
RESERVED_SWITCH_13_BIT4:0,
RESERVED_SWITCH_13_BIT5:0,
RESERVED_SWITCH_13_BIT6:0,
RESERVED_SWITCH_13_BIT7:0,
RESERVED_SWITCH_13_BIT8:0,
RESERVED_SWITCH_13_BIT9:0,
RESERVED_SWITCH_13_BIT10:0,
RESERVED_SWITCH_13_BIT11:0,
RESERVED_SWITCH_13_BIT12:0,
RESERVED_SWITCH_13_BIT13:0,
RESERVED_SWITCH_13_BIT14:0,
RESERVED_SWITCH_13_BIT15:0,
RESERVED_SWITCH_13_BIT16:0,
RESERVED_SWITCH_13_BIT17:0,
RESERVED_SWITCH_13_BIT18:0,
RESERVED_SWITCH_13_BIT19:0,
RESERVED_SWITCH_13_BIT20:0,
RESERVED_SWITCH_13_BIT21:0,
RESERVED_SWITCH_13_BIT22:0,
RESERVED_SWITCH_13_BIT23:0,
RESERVED_SWITCH_13_BIT24:0,
RESERVED_SWITCH_13_BIT25:0,
RESERVED_SWITCH_13_BIT26:0,
RESERVED_SWITCH_13_BIT27:0,
RESERVED_SWITCH_13_BIT28:0,
RESERVED_SWITCH_13_BIT29:0,
RESERVED_SWITCH_13_BIT30:0,
RESERVED_SWITCH_13_BIT31:0,
RESERVED_SWITCH_13_BIT32:0
HspaTi BSC690 ADD WRFD- HSDPA Meaning: Length of the HSPA serving cell change
merLen 0 UCELL 010610 Introduc penalty timer. This timer shall be started after the
HOCO WRFD- tion HSPA serving cell is changed. No more serving cell
MM 010612 Package change shall be performed until the timer expires. The
MOD HSUPA value 0 means this timer shall not be started and
WRFD- serving cell change be initiated immediately.
UCELL 0106120 Introduc
HOCO 4 tion GUI Value Range: 0~1024
MM Package Unit: s
WRFD-
0106100 HSUPA Actual Value Range: 0~1024
6 Mobility
Manage Default Value: 0
ment
HSDPA
Mobility
Manage
ment
HspaTi BSC691 ADD WRFD- HSDPA Meaning: Length of the HSPA serving cell change
merLen 0 UCELL 010610 Introduc penalty timer. This timer shall be started after the
HOCO WRFD- tion HSPA serving cell is changed. No more serving cell
MM 010612 Package change shall be performed until the timer expires. The
MOD HSUPA value 0 means this timer shall not be started and
WRFD- serving cell change be initiated immediately.
UCELL 0106120 Introduc
HOCO 4 tion GUI Value Range: 0~1024
MM Package Unit: s
WRFD-
0106100 HSUPA Actual Value Range: 0~1024
6 Mobility
Manage Default Value: 0
ment
HSDPA
Mobility
Manage
ment
RlRstrT BSC690 SET WRFD- 3GPP Meaning: A timer to RNC wait for radio link
mr 0 USTAT 010101 R9 restoration indication in the radio link procedure.
ETIME WRFD- Specific GUI Value Range: 100~300000
R 140103 ations
Unit: ms
Call
Reestabl Actual Value Range: 100~300000
ishment Default Value: 11000
RlRstrT BSC691 SET WRFD- 3GPP Meaning: A timer to RNC wait for radio link
mr 0 USTAT 010101 R9 restoration indication in the radio link procedure.
ETIME WRFD- Specific GUI Value Range: 100~300000
R 140103 ations
Unit: ms
Call
Reestabl Actual Value Range: 100~300000
ishment Default Value: 11000
MaxEdc BSC690 SET WRFD- HSUPA Meaning: This parameter determines the maximum
hCellIn 0 UHOCO 0106120 Mobility number of links in the EDCH active set. When the
ActiveS MM 4 Manage RNC acts as the SRNC, the number of links in the
et ment EDCH active set for all the UEs under the RNC
cannot exceed the parameter value. If the parameter
value is too large, a lot of resources on the RAN side
will be occupied as the same data is transferred over
multiple EDCH links in macro diversity, thus affecting
the system performance. If this parameter value is too
small, insufficient combination gain can be achieved
in macro diversity by the EDCH, which causes
excessive retransmissions and affects the UE speed.
GUI Value Range: 1~4
Unit: None
Actual Value Range: 1~4
Default Value: 3
MaxEdc BSC691 SET WRFD- HSUPA Meaning: This parameter determines the maximum
hCellIn 0 UHOCO 0106120 Mobility number of links in the EDCH active set. When the
ActiveS MM 4 Manage RNC acts as the SRNC, the number of links in the
et ment EDCH active set for all the UEs under the RNC
cannot exceed the parameter value. If the parameter
value is too large, a lot of resources on the RAN side
will be occupied as the same data is transferred over
multiple EDCH links in macro diversity, thus affecting
the system performance. If this parameter value is too
small, insufficient combination gain can be achieved
in macro diversity by the EDCH, which causes
excessive retransmissions and affects the UE speed.
GUI Value Range: 1~4
Unit: None
Actual Value Range: 1~4
Default Value: 3
CSVoice BSC690 ADD WRFD- HSDPA Meaning: Indicates whether degrade HSPA to DCH
OverHs 0 UNRNC 0106101 Dynami procedure is performed before the relocation
paSuppI MOD 9 c Power procedure when the CS services are carried on the
nd UNRNC Allocati HSPA. If this parameter is set to OFF, the HSPA needs
on to be degraded to the DCH before the relocation
procedure. If this parameter is set to ON, the HSPA
need not be degraded to the DCH before the relocation
procedure.
GUI Value Range: OFF, ON
Unit: None
Actual Value Range: OFF, ON
Default Value: OFF
CSVoice BSC691 ADD WRFD- HSDPA Meaning: Indicates whether degrade HSPA to DCH
OverHs 0 UNRNC 0106101 Dynami procedure is performed before the relocation
paSuppI MOD 9 c Power procedure when the CS services are carried on the
nd UNRNC Allocati HSPA. If this parameter is set to OFF, the HSPA needs
on to be degraded to the DCH before the relocation
procedure. If this parameter is set to ON, the HSPA
need not be degraded to the DCH before the relocation
procedure.
GUI Value Range: OFF, ON
Unit: None
Actual Value Range: OFF, ON
Default Value: OFF
HystFor BSC690 ADD WRFD- Inter Meaning: This parameter specifies the hysteretic value
1J 0 UCELLI 020203 RNC for event 1J. The value of this parameter is associated
NTRAF WRFD- Soft with the slow fading, and it can be used to reduce
REQHO 020202 Handov ping-pong handovers and incorrect handovers. For
MOD er details on the definition of this parameter, see 3GPP
UCELLI Intra TS 25.331.In addition, filter coefficient and interval
NTRAF RNC time must be considered in setting this parameter.
REQHO Soft GUI Value Range: 0~15
Handov Unit: 0.5dB
er
Actual Value Range: 0~7.5
Default Value: 8
HystFor BSC691 ADD WRFD- Inter Meaning: This parameter specifies the hysteretic value
1J 0 UCELLI 020203 RNC for event 1J. The value of this parameter is associated
NTRAF WRFD- Soft with the slow fading, and it can be used to reduce
REQHO 020202 Handov ping-pong handovers and incorrect handovers. For
MOD er details on the definition of this parameter, see 3GPP
UCELLI Intra TS 25.331.In addition, filter coefficient and interval
NTRAF RNC time must be considered in setting this parameter.
REQHO Soft GUI Value Range: 0~15
Handov Unit: 0.5dB
er
Actual Value Range: 0~7.5
Default Value: 8
PeriodM BSC690 ADD WRFD- Inter Meaning: Number of times event 1J is reported after
RReport 0 UCELLI 020203 RNC the reporting mode is changed to periodic reporting.
Numfor NTRAF WRFD- Soft When the number of times event 1J is reported
1J REQHO 020202 Handov exceeds this parameter value, periodic reporting of
MOD er event 1J is disabled.
UCELLI Intra GUI Value Range: D1, D2, D4, D8, D16, D32, D64,
NTRAF RNC INFINITY
REQHO Soft Unit: None
Handov
er Actual Value Range: 1, 2, 4, 8, 16, 32, 64, INFINITY
Default Value: D64
PeriodM BSC691 ADD WRFD- Inter Meaning: Number of times event 1J is reported after
RReport 0 UCELLI 020203 RNC the reporting mode is changed to periodic reporting.
Numfor NTRAF WRFD- Soft When the number of times event 1J is reported
1J REQHO 020202 Handov exceeds this parameter value, periodic reporting of
MOD er event 1J is disabled.
UCELLI Intra GUI Value Range: D1, D2, D4, D8, D16, D32, D64,
NTRAF RNC INFINITY
REQHO Soft Unit: None
Handov
er Actual Value Range: 1, 2, 4, 8, 16, 32, 64, INFINITY
Default Value: D64
ReportIn BSC690 ADD WRFD- Inter Meaning: Interval at which event 1J is reported after
tervalfor 0 UCELLI 020203 RNC the reporting mode is changed to periodical reporting.
1J NTRAF WRFD- Soft Generally, event 1J is reported only once. To avoid the
REQHO 020202 Handov loss of measurement reports, the UE set the mode of
MOD er reporting event 1J to periodical if the cell reporting
UCELLI Intra event 1J is not added to the DCH active set in a
NTRAF RNC specified period of time. Event 1J is reported for
REQHO Soft "PeriodMRReportNumfor1J" times at the interval
Handov specified by this parameter.If the mode of reporting
er event 1J is set to "NON_PERIODIC_REPORT", the
UE cannot change the event 1J reporting mode to
periodical.
GUI Value Range: NON_PERIODIC_REPORT,
D250, D500, D1000, D2000, D4000, D8000, D16000
Unit: ms
Actual Value Range: NON_PERIODIC_REPORT,
250, 500, 1000, 2000, 4000, 8000, 16000
Default Value: D1000
ReportIn BSC691 ADD WRFD- Inter Meaning: Interval at which event 1J is reported after
tervalfor 0 UCELLI 020203 RNC the reporting mode is changed to periodical reporting.
1J NTRAF WRFD- Soft Generally, event 1J is reported only once. To avoid the
REQHO 020202 Handov loss of measurement reports, the UE set the mode of
MOD er reporting event 1J to periodical if the cell reporting
UCELLI Intra event 1J is not added to the DCH active set in a
NTRAF RNC specified period of time. Event 1J is reported for
REQHO Soft "PeriodMRReportNumfor1J" times at the interval
Handov specified by this parameter.If the mode of reporting
er event 1J is set to "NON_PERIODIC_REPORT", the
UE cannot change the event 1J reporting mode to
periodical.
GUI Value Range: NON_PERIODIC_REPORT,
D250, D500, D1000, D2000, D4000, D8000, D16000
Unit: ms
Actual Value Range: NON_PERIODIC_REPORT,
250, 500, 1000, 2000, 4000, 8000, 16000
Default Value: D1000
CPC_DTX_DRX_SUPPORT(CPC DTX-DRX
support indicator),
CPC_HS_SCCH_LESS_OPER_SUPPORT(CPC HS-
SCCH less operation support indicator),
HSPAPLUS_MIMO_SUPPORT(MIMO support
indicator),
FLEX_MACD_PDU_SIZE_SUPPORT(flexible
MAC-d PDU Size support indicator),
FDPCH_SLOT_FORMAT_SUPPORT(F-DPCH slot
format support indicator),
HSPAPLUS_DL_64QAM_SUPPORT(downlink
64QAM support indicator)
Unit: None
Actual Value Range:
DELAY_ACTIVATION_SUPPORT,
HSDSCH_SUPPORT, FDPCH_SUPPORT,
EDCH_SUPPORT, EDCH_2MS_TTI_SUPPORT,
EDCH_2SF2_AND_2SF4_SUPPORT,
EDCH_2SF2_SUPPORT, EDCH_2SF4_SUPPORT,
EDCH_SF4_SUPPORT, EDCH_SF8_SUPPORT,
EDCH_HARQ_IR_COMBIN_SUPPORT,
EDCH_HARQ_CHASE_COMBIN_SUPPORT,
CPC_DTX_DRX_SUPPORT,
CPC_HS_SCCH_LESS_OPER_SUPPORT,
HSPAPLUS_MIMO_SUPPORT,
FLEX_MACD_PDU_SIZE_SUPPORT,
FDPCH_SLOT_FORMAT_SUPPORT,
HSPAPLUS_DL_64QAM_SUPPORT
Default Value: None
CPC_DTX_DRX_SUPPORT(CPC DTX-DRX
support indicator),
CPC_HS_SCCH_LESS_OPER_SUPPORT(CPC HS-
SCCH less operation support indicator),
HSPAPLUS_MIMO_SUPPORT(MIMO support
indicator),
FLEX_MACD_PDU_SIZE_SUPPORT(flexible
MAC-d PDU Size support indicator),
FDPCH_SLOT_FORMAT_SUPPORT(F-DPCH slot
format support indicator),
HSPAPLUS_DL_64QAM_SUPPORT(downlink
64QAM support indicator)
Unit: None
Actual Value Range:
DELAY_ACTIVATION_SUPPORT,
HSDSCH_SUPPORT, FDPCH_SUPPORT,
EDCH_SUPPORT, EDCH_2MS_TTI_SUPPORT,
EDCH_2SF2_AND_2SF4_SUPPORT,
EDCH_2SF2_SUPPORT, EDCH_2SF4_SUPPORT,
EDCH_SF4_SUPPORT, EDCH_SF8_SUPPORT,
EDCH_HARQ_IR_COMBIN_SUPPORT,
EDCH_HARQ_CHASE_COMBIN_SUPPORT,
CPC_DTX_DRX_SUPPORT,
CPC_HS_SCCH_LESS_OPER_SUPPORT,
HSPAPLUS_MIMO_SUPPORT,
FLEX_MACD_PDU_SIZE_SUPPORT,
FDPCH_SLOT_FORMAT_SUPPORT,
HSPAPLUS_DL_64QAM_SUPPORT
Default Value: None
WRFD- 2x2
021200 MIMO
HSUPA
2ms/
10ms
TTI
Handov
er
Downlin
k
64QAM
DB-
HSDPA
SRB
over
HSUPA
HCS
(Hierarc
hical
Cell
Structur
e)
Cell
Structur
e)
Channel BSC690 SET WRFD- HSUPA Meaning: This parameter specifies the value of the
RetryTi 0 UCOIF 0106140 2ms TTI channel retry timer. The timer will start when traffic is
merLen TIMER 3 Dynami set up or reconfigured and some higher technique is
WRFD- c not configured by some reason except for the
021101 Channel capability of UE or cell. Channel retry will be
Configu performed after this timer expires.
WRFD-
ration GUI Value Range: 0~180
010694
Control Unit: s
WRFD- (DCCC)
010693 Actual Value Range: 0~180
UL
WRFD- 16QAM Default Value: 5
150207 DL
WRFD- 64QAM
010652 +MIMO
WRFD- 4C-
010686 HSDPA
SRB
WRFD-
over
010687
HSDPA
WRFD- CPC -
010684 DTX /
WRFD- DRX
010685 CPC -
WRFD- HS-
010683 SCCH
less
WRFD- operatio
0106100 n
8
2x2
WRFD- MIMO
150209
Downlin
WRFD- k
0106120 Enhance
6 d L2
WRFD- Downlin
140204 k
64QAM
WRFD-
010696 Interacti
ve and
WRFD- Backgro
150250 und
WRFD- Traffic
010636 Class on
HSDPA
WRFD-
010630 DB-
HSDPA
WRFD- Interacti
010632 ve and
WRFD- Backgro
0106111 und
2 Traffic
Class on
HSUPA
DC-
HSUPA
DC-
HSDPA
3C-
HSDPA
SRB
over
HSUPA
Streami
ng
Traffic
Class on
HSDPA
Streami
ng
Traffic
Class on
HSUPA
HSDPA
DRD
Channel BSC691 SET WRFD- HSUPA Meaning: This parameter specifies the value of the
RetryTi 0 UCOIF 0106140 2ms TTI channel retry timer. The timer will start when traffic is
merLen TIMER 3 Dynami set up or reconfigured and some higher technique is
WRFD- c not configured by some reason except for the
021101 Channel capability of UE or cell. Channel retry will be
Configu performed after this timer expires.
WRFD-
ration GUI Value Range: 0~180
010694
Control Unit: s
WRFD- (DCCC)
010693 Actual Value Range: 0~180
UL
WRFD- 16QAM Default Value: 5
150207 DL
WRFD- 64QAM
010652 +MIMO
WRFD- 4C-
010686 HSDPA
SRB
WRFD-
over
010687
HSDPA
WRFD- CPC -
010684 DTX /
WRFD- DRX
010685 CPC -
WRFD- HS-
010683 SCCH
less
WRFD- operatio
0106100 n
8
2x2
WRFD- MIMO
150209
Downlin
WRFD- k
0106120 Enhance
6 d L2
WRFD- Downlin
140204 k
64QAM
WRFD-
010696 Interacti
ve and
WRFD- Backgro
150250 und
WRFD- Traffic
010636 Class on
HSDPA
WRFD-
010630 DB-
HSDPA
WRFD- Interacti
010632 ve and
WRFD- Backgro
0106111 und
2 Traffic
Class on
HSUPA
DC-
HSUPA
DC-
HSDPA
3C-
HSDPA
SRB
over
HSUPA
Streami
ng
Traffic
Class on
HSDPA
Streami
ng
Traffic
Class on
HSUPA
HSDPA
DRD
RetryCa BSC690 SET WRFD- HSUPA Meaning: This parameter specifies which HSPA
pability 0 UFRC 0106140 2ms TTI technologies can be retried by UEs. When the HSPA
3 DC- technologies are selected and currently UE is not
WRFD- HSDPA using them, "RNC" will initiate these HSPA
010699 +MIMO technologies retry for UE. This parameter takes effect
only when services running on the UE are carried over
WRFD- Macro- the HSPA channel. The HSDPA_SFDC and
151209 Micro HSDPA_DF3C switch are reserved for the MF-
DC- HSDPA(multiflow HSDPA) function and cannot be
WRFD- HSDPA
150207 used in the current version.
4C- GUI Value Range: SRB_OVER_HSDPA,
WRFD- HSDPA
010652 SRB_OVER_HSUPA, TTI_2MS, MIMO, 64QAM,
SRB DL_L2_ENHANCE, DTX_DRX,
WRFD- over HSSCCH_LESS_OPERATION, MIMO_64QAM,
010686 HSDPA DC_HSDPA, UL_L2_ENHANCE, UL_16QAM,
WRFD- CPC - EDPCCH_BOOSTING, DCMIMO_HSDPA,
010687 DTX / DC_HSUPA, HSDPA_4C_MIMO, HSDPA_4C,
DRX DBMIMO_HSDPA, DB_HSDPA, HSDPA_SFDC,
WRFD-
HSDPA_DF3C
010684 CPC -
HS- Unit: None
WRFD-
010685 SCCH Actual Value Range: SRB_OVER_HSDPA,
less SRB_OVER_HSUPA, TTI_2MS, MIMO, 64QAM,
WRFD- operatio DL_L2_ENHANCE, DTX_DRX,
010695 n HSSCCH_LESS_OPERATION, MIMO_64QAM,
WRFD- 2x2 DC_HSDPA, UL_L2_ENHANCE, UL_16QAM,
010683 MIMO EDPCCH_BOOSTING, DCMIMO_HSDPA,
WRFD- DC_HSUPA, HSDPA_4C_MIMO, HSDPA_4C,
Downlin
010697 DBMIMO_HSDPA, DB_HSDPA, HSDPA_SFDC,
k
HSDPA_DF3C
WRFD- Enhance
d L2 Default Value: SRB_OVER_HSDPA:
010694
0,SRB_OVER_HSUPA:0,TTI_2MS:0,MIMO:
UL
WRFD- 1,64QAM:1,DL_L2_ENHANCE:1,DTX_DRX:
Layer 2
150227 1,HSSCCH_LESS_OPERATION:1,MIMO_64QAM:
Improve
WRFD- 0,DC_HSDPA:0,UL_L2_ENHANCE:0,UL_16QAM:
ment
150209 0,EDPCCH_BOOSTING:0,DCMIMO_HSDPA:
Downlin 0,DC_HSUPA:0,HSDPA_4C_MIMO:0,HSDPA_4C:
WRFD- k 0,DBMIMO_HSDPA:0,DB_HSDPA:
150250 64QAM 0,HSDPA_SFDC:0, HSDPA_DF3C:0
WRFD- E-
170203 DPCCH
Boostin
WRFD-
g
010636
UL
WRFD-
16QAM
010696
DB-
WRFD- HSDPA
150223 +MIMO
WRFD- DB-
010693 HSDPA
3C-
HSDPA
Uplink
Control
Channel
OLPC
SRB
over
HSUPA
DC-
HSDPA
MC-
HSDPA
+MIMO
DL
64QAM
+MIMO
RetryCa BSC691 SET WRFD- HSUPA Meaning: This parameter specifies which HSPA
pability 0 UFRC 0106140 2ms TTI technologies can be retried by UEs. When the HSPA
3 DC- technologies are selected and currently UE is not
WRFD- HSDPA using them, "RNC" will initiate these HSPA
010699 +MIMO technologies retry for UE. This parameter takes effect
only when services running on the UE are carried over
WRFD- Macro- the HSPA channel. The HSDPA_SFDC and
151209 Micro HSDPA_DF3C switch are reserved for the MF-
DC- HSDPA(multiflow HSDPA) function and cannot be
WRFD- HSDPA
150207 used in the current version.
4C- GUI Value Range: SRB_OVER_HSDPA,
WRFD- HSDPA
010652 SRB_OVER_HSUPA, TTI_2MS, MIMO, 64QAM,
SRB DL_L2_ENHANCE, DTX_DRX,
WRFD- over HSSCCH_LESS_OPERATION, MIMO_64QAM,
010686 HSDPA DC_HSDPA, UL_L2_ENHANCE, UL_16QAM,
WRFD- CPC - EDPCCH_BOOSTING, DCMIMO_HSDPA,
010687 DTX / DC_HSUPA, HSDPA_4C_MIMO, HSDPA_4C,
DRX DBMIMO_HSDPA, DB_HSDPA, HSDPA_SFDC,
WRFD-
HSDPA_DF3C
010684 CPC -
HS- Unit: None
WRFD-
010685 SCCH Actual Value Range: SRB_OVER_HSDPA,
less SRB_OVER_HSUPA, TTI_2MS, MIMO, 64QAM,
WRFD- operatio DL_L2_ENHANCE, DTX_DRX,
010695 n HSSCCH_LESS_OPERATION, MIMO_64QAM,
WRFD- 2x2 DC_HSDPA, UL_L2_ENHANCE, UL_16QAM,
010683 MIMO EDPCCH_BOOSTING, DCMIMO_HSDPA,
WRFD- DC_HSUPA, HSDPA_4C_MIMO, HSDPA_4C,
Downlin
010697 DBMIMO_HSDPA, DB_HSDPA, HSDPA_SFDC,
k
HSDPA_DF3C
WRFD- Enhance
d L2 Default Value: SRB_OVER_HSDPA:
010694
0,SRB_OVER_HSUPA:0,TTI_2MS:0,MIMO:
UL
WRFD- 1,64QAM:1,DL_L2_ENHANCE:1,DTX_DRX:
Layer 2
150227 1,HSSCCH_LESS_OPERATION:1,MIMO_64QAM:
Improve
WRFD- 0,DC_HSDPA:0,UL_L2_ENHANCE:0,UL_16QAM:
ment
150209 0,EDPCCH_BOOSTING:0,DCMIMO_HSDPA:
Downlin 0,DC_HSUPA:0,HSDPA_4C_MIMO:0,HSDPA_4C:
WRFD- k 0,DBMIMO_HSDPA:0,DB_HSDPA:
150250 64QAM 0,HSDPA_SFDC:0, HSDPA_DF3C:0
WRFD- E-
170203 DPCCH
Boostin
WRFD-
g
010636
UL
WRFD-
16QAM
010696
DB-
WRFD- HSDPA
150223 +MIMO
WRFD- DB-
010693 HSDPA
3C-
HSDPA
Uplink
Control
Channel
OLPC
SRB
over
HSUPA
DC-
HSDPA
MC-
HSDPA
+MIMO
DL
64QAM
+MIMO
HspaTi BSC690 SET WRFD- HSDPA Meaning: Length of the HSPA serving cell change
merLen 0 UHOCO 0106100 Mobility penalty timer. This timer shall be started after the
MM 6 Manage HSPA serving cell is changed. No more serving cell
WRFD- ment change shall be performed until the timer expires. The
0106120 HSUPA value 0 means this timer shall not be started and
4 Mobility serving cell change be initiated immediately.
Manage GUI Value Range: 0~1024
ment Unit: s
Actual Value Range: 0~1024
Default Value: 0
HspaTi BSC691 SET WRFD- HSDPA Meaning: Length of the HSPA serving cell change
merLen 0 UHOCO 0106100 Mobility penalty timer. This timer shall be started after the
MM 6 Manage HSPA serving cell is changed. No more serving cell
WRFD- ment change shall be performed until the timer expires. The
0106120 HSUPA value 0 means this timer shall not be started and
4 Mobility serving cell change be initiated immediately.
Manage GUI Value Range: 0~1024
ment Unit: s
Actual Value Range: 0~1024
Default Value: 0
HCSPri BSC690 ADD WRFD- Intra Meaning: HCS priority of a cell in an HCS network.
o 0 UCELL 010801 RNC The value of this parameter depends on HCS rules. A
HCS WRFD- Cell small value indicates a low HCS priority. The value 0
MOD 021200 Update indicates the highest-hierarchy cell and the value 7
UCELL HCS indicates the lowest-hierarchy cell. High-hierarchy
WRFD- cells are macro cells having large coverage areas
HCS 010802 (Hierarc
hical where UEs move at high speeds. Low-hierarchy cells
Cell are micro cells having small coverage areas where
Structur UEs move at low speeds. For details, see 3GPP TS
e) 25.304.
Inter GUI Value Range: 0~7
RNC Unit: None
Cell Actual Value Range: 0~7
Update
Default Value: 0
HCSPri BSC691 ADD WRFD- Intra Meaning: HCS priority of a cell in an HCS network.
o 0 UCELL 010801 RNC The value of this parameter depends on HCS rules. A
HCS WRFD- Cell small value indicates a low HCS priority. The value 0
MOD 021200 Update indicates the highest-hierarchy cell and the value 7
UCELL HCS indicates the lowest-hierarchy cell. High-hierarchy
WRFD- cells are macro cells having large coverage areas
HCS 010802 (Hierarc
hical where UEs move at high speeds. Low-hierarchy cells
Cell are micro cells having small coverage areas where
Structur UEs move at low speeds. For details, see 3GPP TS
e) 25.304.
Inter GUI Value Range: 0~7
RNC Unit: None
Cell Actual Value Range: 0~7
Update
Default Value: 0
TrigTim BSC690 ADD WRFD- Inter Meaning: Interval between detection of event 2C and
e2C 0 UCELLI 020103 Frequen sending of the measurement report.
NTERF WRFD- cy Load GUI Value Range: D0, D10, D20, D40, D60, D80,
REQHO 020304 Balance D100, D120, D160, D200, D240, D320, D640,
NCOV Inter D1280, D2560, D5000
MOD Frequen Unit: ms
UCELLI cy Hard
NTERF Handov Actual Value Range: 0, 10, 20, 40, 60, 80, 100, 120,
REQHO er Based 160, 200, 240, 320, 640, 1280, 2560, 5000
NCOV on DL Default Value: D640
QoS
TrigTim BSC691 ADD WRFD- Inter Meaning: Interval between detection of event 2C and
e2C 0 UCELLI 020103 Frequen sending of the measurement report.
NTERF WRFD- cy Load GUI Value Range: D0, D10, D20, D40, D60, D80,
REQHO 020304 Balance D100, D120, D160, D200, D240, D320, D640,
NCOV Inter D1280, D2560, D5000
MOD Frequen Unit: ms
UCELLI cy Hard
NTERF Handov Actual Value Range: 0, 10, 20, 40, 60, 80, 100, 120,
REQHO er Based 160, 200, 240, 320, 640, 1280, 2560, 5000
NCOV on DL Default Value: D640
QoS
Hystfor2 BSC690 ADD WRFD- Inter Meaning: Event 2C hysteresis. The hysteresis can be
C 0 UCELLI 020103 Frequen the Ec/No or RSCP. For details, see 3GPP TS 25.331.
NTERF cy Load GUI Value Range: 0~29
REQHO Balance
NCOV Unit: 0.5dB
Hystfor2 BSC691 ADD WRFD- Inter Meaning: Event 2C hysteresis. The hysteresis can be
C 0 UCELLI 020103 Frequen the Ec/No or RSCP. For details, see 3GPP TS 25.331.
NTERF cy Load GUI Value Range: 0~29
REQHO Balance
NCOV Unit: 0.5dB
IFAntiPi BSC690 SET WRFD- Inter- Meaning: Length of a timer for preventing non-
ngpangT 0 UHOCO 020309 RAT coverage-based inter-frequency handovers. After
imerLen MM WRFD- Handov coverage-based handovers, UE location-based multi-
gth 020304 er Based band DRDs, and macro and micro correlative inter-
on DL frequency handovers are successful, the RNC starts
WRFD- QoS this timer to prevent frequent handovers or
020305 measurements in the new serving cell caused the non-
Inter
WRFD- Frequen coverage factors such as by load, rate estimation,
020306 cy Hard MBMS channel reselection, and QoS.
Handov GUI Value Range: 0~120
er Based Unit: s
on DL
QoS Actual Value Range: 0~120
IFAntiPi BSC691 SET WRFD- Inter- Meaning: Length of a timer for preventing non-
ngpangT 0 UHOCO 020309 RAT coverage-based inter-frequency handovers. After
imerLen MM WRFD- Handov coverage-based handovers, UE location-based multi-
gth 020304 er Based band DRDs, and macro and micro correlative inter-
on DL frequency handovers are successful, the RNC starts
WRFD- QoS this timer to prevent frequent handovers or
020305 measurements in the new serving cell caused the non-
Inter
WRFD- Frequen coverage factors such as by load, rate estimation,
020306 cy Hard MBMS channel reselection, and QoS.
Handov GUI Value Range: 0~120
er Based Unit: s
on DL
QoS Actual Value Range: 0~120
HystFor BSC690 ADD WRFD- Inter Meaning: This parameter specifies the hysteretic value
1F 0 UCELLI 020203 RNC for event 1F. The value of this parameter is associated
NTRAF WRFD- Soft with the slow fading, and it can be used to reduce
REQHO 020202 Handov ping-pong handovers and incorrect handovers. For
MOD er details on the definition of this parameter, see 3GPP
WRFD- TS 25.331. In addition, filter coefficient and interval
UCELLI 020302 Intra
NTRAF RNC time must be considered in setting this parameter.
REQHO Soft GUI Value Range: 0~15
Handov Unit: 0.5dB
er
Actual Value Range: 0~7.5
Inter
Frequen Default Value: 8
cy Hard
Handov
er Based
on
Coverag
e
HystFor BSC691 ADD WRFD- Inter Meaning: This parameter specifies the hysteretic value
1F 0 UCELLI 020203 RNC for event 1F. The value of this parameter is associated
NTRAF WRFD- Soft with the slow fading, and it can be used to reduce
REQHO 020202 Handov ping-pong handovers and incorrect handovers. For
MOD er details on the definition of this parameter, see 3GPP
WRFD- TS 25.331. In addition, filter coefficient and interval
UCELLI 020302 Intra
NTRAF RNC time must be considered in setting this parameter.
REQHO Soft GUI Value Range: 0~15
Handov Unit: 0.5dB
er
Actual Value Range: 0~7.5
Inter
Frequen Default Value: 8
cy Hard
Handov
er Based
on
Coverag
e
IFHoPin BSC690 ADD WRFD- Inter- Meaning: Duration after which the coverage-based
gPongTi 0 UCELLI 020309 RAT inter-frequency handover, inter-frequency blind
mer NTERF WRFD- Handov handover triggered by event 1F, or QoS-based inter-
REQHO 020302 er Based frequency handover can be re-initiated after the
COV on DL success of such handover.
MOD QoS GUI Value Range: 0~65535
UCELLI Inter Unit: s
NTERF Frequen
REQHO cy Hard Actual Value Range: 0~65535
COV Handov Default Value: 0
er Based
on
Coverag
e
IFHoPin BSC691 ADD WRFD- Inter- Meaning: Duration after which the coverage-based
gPongTi 0 UCELLI 020309 RAT inter-frequency handover, inter-frequency blind
mer NTERF WRFD- Handov handover triggered by event 1F, or QoS-based inter-
REQHO 020302 er Based frequency handover can be re-initiated after the
COV on DL success of such handover.
MOD QoS GUI Value Range: 0~65535
UCELLI Inter Unit: s
NTERF Frequen
REQHO cy Hard Actual Value Range: 0~65535
COV Handov Default Value: 0
er Based
on
Coverag
e
PeriodF BSC690 ADD WRFD- Inter Meaning: Sets the interval between the failure in the
or2B 0 UCELLI 020302 Frequen inter-frequency handover triggered by the event 2B
NTERF WRFD- cy Hard and the inter-frequency handover retry.
REQHO 020304 Handov GUI Value Range: 1~64
COV er Based
on Unit: 500ms
MOD
UCELLI Coverag Actual Value Range: 500~32000
NTERF e Default Value: 1
REQHO Inter
COV Frequen
cy Hard
Handov
er Based
on DL
QoS
PeriodF BSC691 ADD WRFD- Inter Meaning: Sets the interval between the failure in the
or2B 0 UCELLI 020302 Frequen inter-frequency handover triggered by the event 2B
NTERF WRFD- cy Hard and the inter-frequency handover retry.
REQHO 020304 Handov GUI Value Range: 1~64
COV er Based
on Unit: 500ms
MOD
UCELLI Coverag Actual Value Range: 500~32000
NTERF e Default Value: 1
REQHO Inter
COV Frequen
cy Hard
Handov
er Based
on DL
QoS
PeriodF BSC690 ADD WRFD- Inter Meaning: Interval between inter-frequency handover
or2C 0 UCELLI 020103 Frequen re-attempts made by RNC after an inter-frequency
NTERF WRFD- cy Load handover triggered by event 2C fails.
REQHO 020304 Balance GUI Value Range: 1~64
NCOV Inter Unit: 500ms
MOD Frequen
UCELLI cy Hard Actual Value Range: 500~32000
NTERF Handov Default Value: 4
REQHO er Based
NCOV on DL
QoS
PeriodF BSC691 ADD WRFD- Inter Meaning: Interval between inter-frequency handover
or2C 0 UCELLI 020103 Frequen re-attempts made by RNC after an inter-frequency
NTERF WRFD- cy Load handover triggered by event 2C fails.
REQHO 020304 Balance GUI Value Range: 1~64
NCOV Inter Unit: 500ms
MOD Frequen
UCELLI cy Hard Actual Value Range: 500~32000
NTERF Handov Default Value: 4
REQHO er Based
NCOV on DL
QoS
PeriodF BSC690 ADD WRFD- Inter- Meaning: Interval between handover attempts for
or3A 0 UCELLI 020303 RAT event 3A.
NTERR Handov GUI Value Range: 1~64
ATHOC er Based
OV on Unit: 500ms
PeriodF BSC691 ADD WRFD- Inter- Meaning: Interval between handover attempts for
or3A 0 UCELLI 020303 RAT event 3A.
NTERR Handov GUI Value Range: 1~64
ATHOC er Based
OV on Unit: 500ms
AmntOf BSC690 ADD WRFD- Inter- Meaning: Number of handover attempts after the UE
Rpt3A 0 UCELLI 020303 RAT sends to the CN a message indicating that inter-RAT
NTERR Handov handovers triggered by event 3A fail.
ATHOC er Based GUI Value Range: 0~63
OV on
Coverag Unit: None
MOD
UCELLI e Actual Value Range: 0~62, 63(Infinity)
NTERR Default Value: 4
ATHOC
OV
AmntOf BSC691 ADD WRFD- Inter- Meaning: Number of handover attempts after the UE
Rpt3A 0 UCELLI 020303 RAT sends to the CN a message indicating that inter-RAT
NTERR Handov handovers triggered by event 3A fail.
ATHOC er Based GUI Value Range: 0~63
OV on
Coverag Unit: None
MOD
UCELLI e Actual Value Range: 0~62, 63(Infinity)
NTERR Default Value: 4
ATHOC
OV
PeriodF BSC690 ADD WRFD- Inter- Meaning: Interval between handover attempts for
or3C 0 UCELLI 020305 RAT event 3C.
NTERR WRFD- Handov GUI Value Range: 1~64
ATHON 020306 er Based
COV on Unit: 500ms
PeriodF BSC691 ADD WRFD- Inter- Meaning: Interval between handover attempts for
or3C 0 UCELLI 020305 RAT event 3C.
NTERR WRFD- Handov GUI Value Range: 1~64
ATHON 020306 er Based
COV on Unit: 500ms
AmntOf BSC690 ADD WRFD- Inter- Meaning: Number of handover attempts after the UE
Rpt3C 0 UCELLI 020305 RAT sends to the CN a message indicating that inter-RAT
NTERR WRFD- Handov handovers triggered by event 3C fail.
ATHON 020306 er Based GUI Value Range: 0~63
COV on
Service Unit: None
MOD
UCELLI Inter- Actual Value Range: 0~62, 63(Infinity)
NTERR RAT Default Value: 1
ATHON Handov
COV er Based
on Load
AmntOf BSC691 ADD WRFD- Inter- Meaning: Number of handover attempts after the UE
Rpt3C 0 UCELLI 020305 RAT sends to the CN a message indicating that inter-RAT
NTERR WRFD- Handov handovers triggered by event 3C fail.
ATHON 020306 er Based GUI Value Range: 0~63
COV on
Service Unit: None
MOD
UCELLI Inter- Actual Value Range: 0~62, 63(Infinity)
NTERR RAT Default Value: 1
ATHON Handov
COV er Based
on Load
ReportIn BSC690 ADD WRFD- Inter Meaning: Interval at which event 1A is reported after
tervalfor 0 UCELLI 020203 RNC the reporting mode is changed to periodical reporting.
1A NTRAF WRFD- Soft Generally, event 1A is reported only once. To avoid
REQHO 020202 Handov the loss of measurement reports, the UE sets the mode
MOD er of reporting event 1A to periodical if the cell reporting
UCELLI Intra event 1A is not added to the active set in a specified
NTRAF RNC period of time. Event 1A is reported for
REQHO Soft "PeriodMRReportNumfor1A" times at the interval
Handov specified by this parameter. If the mode of reporting
er event 1A is set to "NON_PERIODIC_REPORT", the
UE cannot change the event 1A reporting mode to
periodical.
GUI Value Range: NON_PERIODIC_REPORT,
D250, D500, D1000, D2000, D4000, D8000, D16000
Unit: ms
Actual Value Range: NON_PERIODIC_REPORT,
250, 500, 1000, 2000, 4000, 8000, 16000
Default Value: D4000
ReportIn BSC691 ADD WRFD- Inter Meaning: Interval at which event 1A is reported after
tervalfor 0 UCELLI 020203 RNC the reporting mode is changed to periodical reporting.
1A NTRAF WRFD- Soft Generally, event 1A is reported only once. To avoid
REQHO 020202 Handov the loss of measurement reports, the UE sets the mode
MOD er of reporting event 1A to periodical if the cell reporting
UCELLI Intra event 1A is not added to the active set in a specified
NTRAF RNC period of time. Event 1A is reported for
REQHO Soft "PeriodMRReportNumfor1A" times at the interval
Handov specified by this parameter. If the mode of reporting
er event 1A is set to "NON_PERIODIC_REPORT", the
UE cannot change the event 1A reporting mode to
periodical.
GUI Value Range: NON_PERIODIC_REPORT,
D250, D500, D1000, D2000, D4000, D8000, D16000
Unit: ms
Actual Value Range: NON_PERIODIC_REPORT,
250, 500, 1000, 2000, 4000, 8000, 16000
Default Value: D4000
ReportIn BSC690 ADD WRFD- Inter Meaning: Interval at which event 1A is reported after
tervalfor 0 UCELLI 020203 RNC the reporting mode is changed to periodical reporting.
1C NTRAF WRFD- Soft Generally, event 1C is reported only once. To avoid
REQHO 020202 Handov the loss of measurement reports, the UE set the mode
MOD er of reporting event 1C to periodical if the cell reporting
UCELLI Intra event 1C is not added to the active set in a specified
NTRAF RNC period of time. Event 1C is reported for
REQHO Soft "PeriodMRReportNumfor1C" times at the interval
Handov specified by this parameter.If the mode of reporting
er event 1C is set to "NON_PERIODIC_REPORT", the
UE cannot change the event 1C reporting mode to
periodical.
GUI Value Range: NON_PERIODIC_REPORT,
D250, D500, D1000, D2000, D4000, D8000, D16000
Unit: ms
Actual Value Range: NON_PERIODIC_REPORT,
250, 500, 1000, 2000, 4000, 8000, 16000
Default Value: D4000
ReportIn BSC691 ADD WRFD- Inter Meaning: Interval at which event 1A is reported after
tervalfor 0 UCELLI 020203 RNC the reporting mode is changed to periodical reporting.
1C NTRAF WRFD- Soft Generally, event 1C is reported only once. To avoid
REQHO 020202 Handov the loss of measurement reports, the UE set the mode
MOD er of reporting event 1C to periodical if the cell reporting
UCELLI Intra event 1C is not added to the active set in a specified
NTRAF RNC period of time. Event 1C is reported for
REQHO Soft "PeriodMRReportNumfor1C" times at the interval
Handov specified by this parameter.If the mode of reporting
er event 1C is set to "NON_PERIODIC_REPORT", the
UE cannot change the event 1C reporting mode to
periodical.
GUI Value Range: NON_PERIODIC_REPORT,
D250, D500, D1000, D2000, D4000, D8000, D16000
Unit: ms
Actual Value Range: NON_PERIODIC_REPORT,
250, 500, 1000, 2000, 4000, 8000, 16000
Default Value: D4000
PeriodM BSC690 ADD WRFD- Inter Meaning: Number of times event 1A is reported after
RReport 0 UCELLI 020203 RNC the reporting mode is changed to periodic reporting.
Numfor NTRAF WRFD- Soft When the number of times event 1A is reported
1A REQHO 020202 Handov exceeds this parameter value, periodic reporting of
MOD er event 1A is disabled.
UCELLI Intra GUI Value Range: D1, D2, D4, D8, D16, D32, D64,
NTRAF RNC INFINITY
REQHO Soft Unit: None
Handov
er Actual Value Range: 1, 2, 4, 8, 16, 32, 64, INFINITY
Default Value: D16
PeriodM BSC691 ADD WRFD- Inter Meaning: Number of times event 1A is reported after
RReport 0 UCELLI 020203 RNC the reporting mode is changed to periodic reporting.
Numfor NTRAF WRFD- Soft When the number of times event 1A is reported
1A REQHO 020202 Handov exceeds this parameter value, periodic reporting of
MOD er event 1A is disabled.
UCELLI Intra GUI Value Range: D1, D2, D4, D8, D16, D32, D64,
NTRAF RNC INFINITY
REQHO Soft Unit: None
Handov
er Actual Value Range: 1, 2, 4, 8, 16, 32, 64, INFINITY
Default Value: D16
PeriodM BSC690 ADD WRFD- Inter Meaning: Number of times event 1C is reported after
RReport 0 UCELLI 020203 RNC the reporting mode is changed to periodic reporting.
Numfor NTRAF WRFD- Soft When the number of times event 1C is reported
1C REQHO 020202 Handov exceeds this parameter value, periodic reporting of
MOD er event 1C is disabled.
UCELLI Intra GUI Value Range: D1, D2, D4, D8, D16, D32, D64,
NTRAF RNC INFINITY
REQHO Soft Unit: None
Handov
er Actual Value Range: 1, 2, 4, 8, 16, 32, 64, INFINITY
Default Value: D16
PeriodM BSC691 ADD WRFD- Inter Meaning: Number of times event 1C is reported after
RReport 0 UCELLI 020203 RNC the reporting mode is changed to periodic reporting.
Numfor NTRAF WRFD- Soft When the number of times event 1C is reported
1C REQHO 020202 Handov exceeds this parameter value, periodic reporting of
MOD er event 1C is disabled.
UCELLI Intra GUI Value Range: D1, D2, D4, D8, D16, D32, D64,
NTRAF RNC INFINITY
REQHO Soft Unit: None
Handov
er Actual Value Range: 1, 2, 4, 8, 16, 32, 64, INFINITY
Default Value: D16
IntraFre BSC690 SET None None Meaning: Whether the detection function of missing
qNCell 0 UNCEL intra-frequency neighboring cells is enabled. This
DetectS LDETE switch is turned on. The function of detecting missing
witch CTSWI intra-frequency neighboring cells is enabled. That is,
TCH the UE reports the intra-frequency measurement
results in the detection set to the RNC and the RNC
then reports the detected missing intra-frequency
neighboring cells to the Nastar or LMT. This switch is
turned off. The function of detecting missing intra-
frequency neighboring cells is not enabled.
GUI Value Range: OFF, ON
Unit: None
Actual Value Range: OFF, ON
Default Value: OFF
IntraFre BSC691 SET None None Meaning: Whether the detection function of missing
qNCell 0 UNCEL intra-frequency neighboring cells is enabled. This
DetectS LDETE switch is turned on. The function of detecting missing
witch CTSWI intra-frequency neighboring cells is enabled. That is,
TCH the UE reports the intra-frequency measurement
results in the detection set to the RNC and the RNC
then reports the detected missing intra-frequency
neighboring cells to the Nastar or LMT. This switch is
turned off. The function of detecting missing intra-
frequency neighboring cells is not enabled.
GUI Value Range: OFF, ON
Unit: None
Actual Value Range: OFF, ON
Default Value: OFF
InterFre BSC690 SET None None Meaning: Whether the function of detecting missing
qNCell 0 UNCEL inter-frequency neighboring cells is enabled. This
DetectS LDETE switch is turned on. The function of detecting missing
witch CTSWI inter-frequency neighboring cells is enabled. That is,
TCH the UE reports the inter-frequency measurement
results to the RNC and the RNC then reports the
detected missing inter-frequency neighboring cells to
the Nastar or LMT. This switch is turned off. The
function of detecting missing inter-frequency
neighboring cells is not enabled.
GUI Value Range: OFF, ON
Unit: None
Actual Value Range: OFF, ON
Default Value: OFF
InterFre BSC691 SET None None Meaning: Whether the function of detecting missing
qNCell 0 UNCEL inter-frequency neighboring cells is enabled. This
DetectS LDETE switch is turned on. The function of detecting missing
witch CTSWI inter-frequency neighboring cells is enabled. That is,
TCH the UE reports the inter-frequency measurement
results to the RNC and the RNC then reports the
detected missing inter-frequency neighboring cells to
the Nastar or LMT. This switch is turned off. The
function of detecting missing inter-frequency
neighboring cells is not enabled.
GUI Value Range: OFF, ON
Unit: None
Actual Value Range: OFF, ON
Default Value: OFF
DlSFLi BSC690 SET WRFD- Inter Meaning: Whether the CM is limited by the downlink
mitCMI 0 UCMCF 020302 Frequen spreading factor (SF). Starting the compressed mode
nd WRFD- cy Hard is resource consuming for the fast-moving UEs, so
020303 Handov this parameter is set to control whether the downlink
er Based SF of the current DCH channel should be considered.
on When this parameter is set to FALSE, the enabling of
Coverag CM does not consider the SF of the downlink DCH
e channel; when this parameter is set to TRUE, the
Inter- enabling of CM considers the SF of the downlink
RAT DCH channel.
Handov GUI Value Range: FALSE(Not Limited),
er Based TRUE(Limited)
on Unit: None
Coverag
e Actual Value Range: FALSE, TRUE
Default Value: FALSE(Not Limited)
DlSFLi BSC691 SET WRFD- Inter Meaning: Whether the CM is limited by the downlink
mitCMI 0 UCMCF 020302 Frequen spreading factor (SF). Starting the compressed mode
nd WRFD- cy Hard is resource consuming for the fast-moving UEs, so
020303 Handov this parameter is set to control whether the downlink
er Based SF of the current DCH channel should be considered.
on When this parameter is set to FALSE, the enabling of
Coverag CM does not consider the SF of the downlink DCH
e channel; when this parameter is set to TRUE, the
Inter- enabling of CM considers the SF of the downlink
RAT DCH channel.
Handov GUI Value Range: FALSE(Not Limited),
er Based TRUE(Limited)
on Unit: None
Coverag
e Actual Value Range: FALSE, TRUE
Default Value: FALSE(Not Limited)
6)SPECUSER_NO_RBSETUP_MSG_OPT_SWITC
H(RB SETUP Message Size Reduction Disable
Switch)
Whether to disable the RB SETUP message size
reduction function for special UEs.
1: This switch is turned on and special UEs cannot use
the RB SETUP message size reduction function.
0: This switch is turned off and special UEs can use
the RB SETUP message size reduction function.
7)SPECUSER_REEST_TO_FACH_LIMITATION(R
L Reestablishment on FACH Forbidden for Special
UEs)
Whether to forbid special UEs to reestablish their
radio links (RLs) on the FACH.
1: This switch is turned on, and special UEs cannot
reestablish their RLs on the FACH.
0: This switch is turned off, and special UEs can
reestablish their RLs on the FACH.
8)SPECUSER_WBAMR_RB_RECFG_LIMIT_SWI
TCH(WB-AMR RB RECFG Disable Switch)
Whether to perform the RB RECFG procedure for
special UEs processing AMR-WB or AMR-NB
services.
1: This switch is turned on and the RNC does not
perform the RB RECFG procedure on UEs processing
AMR-WB or AMR-NB services.
0: This switch is turned off and the RNC performs the
RB RECFG procedure on UEs processing AMR-WB
or AMR-NB services.
9)SPECUSER_NO_FAST_RECFG_HHO_SWITCH(
Fast Recfg Prohibit Switch for Special UE in HHO)
Whether to use the asynchronous configuration mode
for a special UE in hard handover scenarios.
1: This switch is turned on and the asynchronous
configuration mode is not used for a specified UE in
hard handover scenarios.
0: This switch is turned off and the asynchronous
configuration mode can be used for a specified UE in
hard handover scenarios.
10)SPECUSER_NO_AMR_NOISE_DETECT_SWIT
CH(UL Garbled Noise Detection and Correction
Inhibition Switch for Special UEs)
SPECUSER_DLRLMAXPWR_RECTIFY_SWITCH,
SPECUSER_SRB_TF_OPT_LIMIT_SWITCH
Unit: None
Actual Value Range:
SPECUSER_4C_HSDPA_LIMIT_SWITCH,
SPECUSER_3C_HSDPA_LIMIT_SWITCH,
SPECUSER_DC_HSDPA_LIMIT_SWITCH,
SPECUSER_DB_HSDPA_LIMIT_SWITCH,
SPECUSER_DC_HSUPA_LIMIT_SWITCH,
SPECUSER_NO_RBSETUP_MSG_OPT_SWITCH,
SPECUSER_REEST_TO_FACH_LIMITATION,
SPECUSER_WBAMR_RB_RECFG_LIMIT_SWITC
H,
SPECUSER_NO_FAST_RECFG_HHO_SWITCH,
SPECUSER_NO_AMR_NOISE_DETECT_SWITCH
,
SPECUSER_NO_HSDPACM_SWITCH,
SPECUSER_NO_HSUPACM_SWITCH,
SPECUSER_NO_EHSPACM_SWITCH,
SPECUSER_GUL_CM_LIMIT_SWITCH,
SPECUSER_SECMOD_CU_OVERLAP_OPT_SWI
TCH,
SPECUSER_SECMOD_CU_OVERLAP_CMP_SWI
TCH,
SPECUSER_DLRLMAXPWR_RECTIFY_SWITCH,
SPECUSER_SRB_TF_OPT_LIMIT_SWITCH
Default Value:
SPECUSER_4C_HSDPA_LIMIT_SWITCH:
0,SPECUSER_3C_HSDPA_LIMIT_SWITCH:
0,SPECUSER_DC_HSDPA_LIMIT_SWITCH:
0,SPECUSER_DB_HSDPA_LIMIT_SWITCH:
0,SPECUSER_DC_HSUPA_LIMIT_SWITCH:
0,SPECUSER_NO_RBSETUP_MSG_OPT_SWITCH
:0,SPECUSER_REEST_TO_FACH_LIMITATION:
0,SPECUSER_WBAMR_RB_RECFG_LIMIT_SWIT
CH:
0,SPECUSER_NO_FAST_RECFG_HHO_SWITCH:
0,SPECUSER_NO_AMR_NOISE_DETECT_SWITC
H:0,SPECUSER_NO_HSDPACM_SWITCH:
0,SPECUSER_NO_HSUPACM_SWITCH:
0,SPECUSER_NO_EHSPACM_SWITCH:
0,SPECUSER_GUL_CM_LIMIT_SWITCH:
0,SPECUSER_SECMOD_CU_OVERLAP_OPT_SW
ITCH:
0,SPECUSER_SECMOD_CU_OVERLAP_CMP_S
WITCH:
0,SPECUSER_DLRLMAXPWR_RECTIFY_SWITC
H:0,SPECUSER_SRB_TF_OPT_LIMIT_SWITCH:0
6)SPECUSER_NO_RBSETUP_MSG_OPT_SWITC
H(RB SETUP Message Size Reduction Disable
Switch)
Whether to disable the RB SETUP message size
reduction function for special UEs.
1: This switch is turned on and special UEs cannot use
the RB SETUP message size reduction function.
0: This switch is turned off and special UEs can use
the RB SETUP message size reduction function.
7)SPECUSER_REEST_TO_FACH_LIMITATION(R
L Reestablishment on FACH Forbidden for Special
UEs)
Whether to forbid special UEs to reestablish their
radio links (RLs) on the FACH.
1: This switch is turned on, and special UEs cannot
reestablish their RLs on the FACH.
0: This switch is turned off, and special UEs can
reestablish their RLs on the FACH.
8)SPECUSER_WBAMR_RB_RECFG_LIMIT_SWI
TCH(WB-AMR RB RECFG Disable Switch)
Whether to perform the RB RECFG procedure for
special UEs processing AMR-WB or AMR-NB
services.
1: This switch is turned on and the RNC does not
perform the RB RECFG procedure on UEs processing
AMR-WB or AMR-NB services.
0: This switch is turned off and the RNC performs the
RB RECFG procedure on UEs processing AMR-WB
or AMR-NB services.
9)SPECUSER_NO_FAST_RECFG_HHO_SWITCH(
Fast Recfg Prohibit Switch for Special UE in HHO)
Whether to use the asynchronous configuration mode
for a special UE in hard handover scenarios.
1: This switch is turned on and the asynchronous
configuration mode is not used for a specified UE in
hard handover scenarios.
0: This switch is turned off and the asynchronous
configuration mode can be used for a specified UE in
hard handover scenarios.
10)SPECUSER_NO_AMR_NOISE_DETECT_SWIT
CH(UL Garbled Noise Detection and Correction
Inhibition Switch for Special UEs)
SPECUSER_DLRLMAXPWR_RECTIFY_SWITCH,
SPECUSER_SRB_TF_OPT_LIMIT_SWITCH
Unit: None
Actual Value Range:
SPECUSER_4C_HSDPA_LIMIT_SWITCH,
SPECUSER_3C_HSDPA_LIMIT_SWITCH,
SPECUSER_DC_HSDPA_LIMIT_SWITCH,
SPECUSER_DB_HSDPA_LIMIT_SWITCH,
SPECUSER_DC_HSUPA_LIMIT_SWITCH,
SPECUSER_NO_RBSETUP_MSG_OPT_SWITCH,
SPECUSER_REEST_TO_FACH_LIMITATION,
SPECUSER_WBAMR_RB_RECFG_LIMIT_SWITC
H,
SPECUSER_NO_FAST_RECFG_HHO_SWITCH,
SPECUSER_NO_AMR_NOISE_DETECT_SWITCH
,
SPECUSER_NO_HSDPACM_SWITCH,
SPECUSER_NO_HSUPACM_SWITCH,
SPECUSER_NO_EHSPACM_SWITCH,
SPECUSER_GUL_CM_LIMIT_SWITCH,
SPECUSER_SECMOD_CU_OVERLAP_OPT_SWI
TCH,
SPECUSER_SECMOD_CU_OVERLAP_CMP_SWI
TCH,
SPECUSER_DLRLMAXPWR_RECTIFY_SWITCH,
SPECUSER_SRB_TF_OPT_LIMIT_SWITCH
Default Value:
SPECUSER_4C_HSDPA_LIMIT_SWITCH:
0,SPECUSER_3C_HSDPA_LIMIT_SWITCH:
0,SPECUSER_DC_HSDPA_LIMIT_SWITCH:
0,SPECUSER_DB_HSDPA_LIMIT_SWITCH:
0,SPECUSER_DC_HSUPA_LIMIT_SWITCH:
0,SPECUSER_NO_RBSETUP_MSG_OPT_SWITCH
:0,SPECUSER_REEST_TO_FACH_LIMITATION:
0,SPECUSER_WBAMR_RB_RECFG_LIMIT_SWIT
CH:
0,SPECUSER_NO_FAST_RECFG_HHO_SWITCH:
0,SPECUSER_NO_AMR_NOISE_DETECT_SWITC
H:0,SPECUSER_NO_HSDPACM_SWITCH:
0,SPECUSER_NO_HSUPACM_SWITCH:
0,SPECUSER_NO_EHSPACM_SWITCH:
0,SPECUSER_GUL_CM_LIMIT_SWITCH:
0,SPECUSER_SECMOD_CU_OVERLAP_OPT_SW
ITCH:
0,SPECUSER_SECMOD_CU_OVERLAP_CMP_S
WITCH:
0,SPECUSER_DLRLMAXPWR_RECTIFY_SWITC
H:0,SPECUSER_SRB_TF_OPT_LIMIT_SWITCH:0
DlCMA BSC690 ADD None None Meaning: Whether the RNC can allocate other SF/2
voidChg 0 UCELL codes instead of the alternative scrambling codes to a
ScCode ALGOS UE if the UE needs to start the compressed mode
Switch WITCH through SF/2 but the adjacent downlink channel codes
MOD cannot be used. When this switch is set to on in the
UCELL preceding scenario, the RNC allocates other available
ALGOS SF/2 codes for the UE to start the compressed mode in
WITCH the downlink. When this switch is set to off, the UE
uses alternative scrambling codes to start the
compressed mode in the downlink.
GUI Value Range: OFF, ON
Unit: None
Actual Value Range: ON, OFF
Default Value: OFF
DlCMA BSC691 ADD None None Meaning: Whether the RNC can allocate other SF/2
voidChg 0 UCELL codes instead of the alternative scrambling codes to a
ScCode ALGOS UE if the UE needs to start the compressed mode
Switch WITCH through SF/2 but the adjacent downlink channel codes
MOD cannot be used. When this switch is set to on in the
UCELL preceding scenario, the RNC allocates other available
ALGOS SF/2 codes for the UE to start the compressed mode in
WITCH the downlink. When this switch is set to off, the UE
uses alternative scrambling codes to start the
compressed mode in the downlink.
GUI Value Range: OFF, ON
Unit: None
Actual Value Range: ON, OFF
Default Value: OFF
DlSFdiv BSC690 ADD WRFD- Code Meaning: Maximum number of downlink channel
2CmVali 0 UCELL 020108 Resourc codes that can be reconfigured to avoid using
dCodeT LDM e alternative scrambling codes for UEs that need to start
hd MOD Manage the compressed mode using SF/2. The unit of this
UCELL ment parameter is SF16 code tree. Alternative scrambling
LDM codes do not need to be used if the reconfigured
downlink channel code C (SF/2, floor(n/2, 1)) is in the
code tree between (SF16, 0) and (SF16, value of this
parameter). Otherwise, alternative scrambling codes
are used for UEs to start the compressed mode.
GUI Value Range: 0~15
Unit: None
Actual Value Range: 0~15
Default Value: 10
DlSFdiv BSC691 ADD WRFD- Code Meaning: Maximum number of downlink channel
2CmVali 0 UCELL 020108 Resourc codes that can be reconfigured to avoid using
dCodeT LDM e alternative scrambling codes for UEs that need to start
hd MOD Manage the compressed mode using SF/2. The unit of this
UCELL ment parameter is SF16 code tree. Alternative scrambling
LDM codes do not need to be used if the reconfigured
downlink channel code C (SF/2, floor(n/2, 1)) is in the
code tree between (SF16, 0) and (SF16, value of this
parameter). Otherwise, alternative scrambling codes
are used for UEs to start the compressed mode.
GUI Value Range: 0~15
Unit: None
Actual Value Range: 0~15
Default Value: 10
13)EFACH_RRC_REG_CMP_SWITCH(E-FACH
RRC Registration Compatibility Switch)
Whether special UEs use the E-FACH to carry their
RRC CONNECTION SETUP messages when the cell
is enabled with E-FACH.
1: This switch is set to on. the RNC retransmits the
last RRC CONNECTION SETUP message on the E-
FACH if special users do not respond to the RRC
CONNECTION SETUP message on the FACH. If the
UE returns an RRC CONNECTION SETUP CMP
message, the UE stays in the CELL_DCH state during
data transmission.
0: This switch is set to off. no special processing is
performed on special users.
14)
P2D_TSID_ERR_UE_RSP_MSG_DISCD_SWITCH
(Discard Responses with Incorrect TRANSCIDs from
UEs During P2D)
Whether the RNC discards a RADIO BEARER
RECONFIGURATION COMPLETE message
received from a UE during P2D state transitions when
the value of the "RRC transaction identifier" IE in the
message is incorrect.
1: This switch is set to on. The RNC discards the
message and waits for the UE's response.
0: This switch is set to off. The RNC rolls back the
P2D state transition procedure.
15)
AMRC_ON_122_AMR_HHO_ROLL_BACK_SWIT
CH (HHO Rollback Switch for 12.2K AMR Services
with AMRC Enabled)
Whether the RNC performs rollback after 12.2 kbit/s
AMR-NB services experience hard handover failures
in the scenario where the narrowband AMRC function
takes effect.
0: This switch is set to off. The RNC does not perform
rollback after 12.2 kbit/s AMR-NB services
experience hard handover failures in the preceding
scenario.
1: This switch is set to on. The RNC performs
rollback after 12.2 kbit/s AMR-NB services
experience hard handover failures in the preceding
scenario.
16)RELOC_IN_RG_COMB_INDEX_ALLOC_SWIT
CH
29)INTERRAT2U_INTEG_PROTECT_OPT_SWITC
H(Integrity Protection Optimization Switch for
Incoming Inter-RAT Handovers)
Whether the optimized integrity protection function is
enabled for incoming L2U or G2U inter-RAT
handovers.
1: This switch is set to on. The integrity protection
function is immediately activated for SRB0 to SRB4
after the incoming L2U or G2U inter-RAT handover is
complete.
0: This switch is set to off. The integrity protection
function is activated only for SRB2 after the incoming
L2U or G2U inter-RAT handover is complete. The
integrity protection for other SRBs (SRB0, SRB1,
SRB3, and SRB4) is activated only after the UE sends
a message.
30)CS_PAGING_OVERLAP_RRC_OPT_SWITCH(
Optimize CS Paging During RRC Procedures)
Whether the RNC performs optimized processing
when a UE is paged in the CS domain during an RRC
connection setup procedure.
1: Indicates that this switch is set to ON. The RNC
performs optimized processing when a UE is paged in
the CS domain during an RRC connection setup
procedure.
0: Indicates that this switch is set to OFF. The access
delay of the CS paging procedure increases.
31)INTRA_NODEB_RLCC_INIT_CAP_OPT_SWIT
CH(Optimize the Rate upon NodeB RL Change for H
Services)
Whether the rate optimization policy is applied in the
scenario where the radio link (RL) for HSPA services
changes inside the NodeB.
1: This switch is set to on. The rate optimization
policy is applied in the scenario where the RL for
HSPA services changes inside the NodeB.
0: This switch is set to off. The rate optimization
policy is not applied in the scenario where the RL for
HSPA services changes inside the NodeB.
32)DRNC_RL_PARA_UPT_OPT_SWITCH(RL
Parameter Update Optimization Switch on RNC)
Whether the RL PARA UPT IND message over the
Iur interface can be correctly processed.
DRNC_RL_REEST_OPT_SWITCH,
URA2FACH_OVERLAP_CELLUPT_PROC_SWIT
CH,
RB_SETUP_F2D_USE_AM_RLC_SWITCH,
RB_RECFG_D2F_USE_AM_RLC_SWITCH,
RB_RECFG_F2D_USE_AM_RLC_SWITCH,
RRC_UE_USER_SMOOTH_OPT_SWITCH,
TRNC_LOAD_CTRL_SWITCH,
IU_SIG_REL_PCH_PAGING_SWITCH,
CPC_OPT_FOR_RLSETUP_SWITCH,
D2P_L2DEACT_FAIL_OPT_SWITCH,
EFACH_RRC_REG_CMP_SWITCH,
P2D_TSID_ERR_UE_RSP_MSG_DISCD_SWITCH,
AMRC_ON_122_AMR_HHO_ROLL_BACK_SWIT
CH,
RELOC_IN_RG_COMB_INDEX_ALLOC_SWITC
H,
SCM_CU_CROSS_SWITCH,
DRNC_HSPA_CM_OPT_SWITCH,
IUB_TRANSID_OPT_SWITCH,
L2_ENHENCE_RECFG_OPT_SWITCH,
ASYN_RL_REEST_OPT_SWITCH,
RNC_IMSI_HO_OPT_SWITCH,
IUR_PRIQUEUE_INFO_TO_MODIFY_OPT_SWIT
CH,
URA_PCH_LAC_RAC_CHG_NO_PAGING_SWIT
CH,
PAGING_OVERLAP_CU_OPT_SWITCH,
SRVCC_RELOC_IN_USE_CS_KEY_SWITCH,
SOCKET_RECEIVE_DATA_CORRECT_SWITCH,
CU_PRI_OVERLAP_OTHER_PROC_SWITCH,
INTERRAT2U_INTEG_PROTECT_OPT_SWITCH,
CS_PAGING_OVERLAP_RRC_OPT_SWITCH,
INTRA_NODEB_RLCC_INIT_CAP_OPT_SWITCH
,
DRNC_RL_PARA_UPT_OPT_SWITCH
Default Value:
RB_RLREEST_AM_TRB_RLC_REEST_SWITCH:
0,RB_SETUP_UM_TRB_RLREEST_ADJUD_OPT_
SWITCH:0,DRNC_RL_REEST_OPT_SWITCH:
1,URA2FACH_OVERLAP_CELLUPT_PROC_SWI
TCH:0,RB_SETUP_F2D_USE_AM_RLC_SWITCH:
0,RB_RECFG_D2F_USE_AM_RLC_SWITCH:
0,RB_RECFG_F2D_USE_AM_RLC_SWITCH:
0,RRC_UE_USER_SMOOTH_OPT_SWITCH:
1,TRNC_LOAD_CTRL_SWITCH:
0,IU_SIG_REL_PCH_PAGING_SWITCH:
0,CPC_OPT_FOR_RLSETUP_SWITCH:
1,D2P_L2DEACT_FAIL_OPT_SWITCH:
0,EFACH_RRC_REG_CMP_SWITCH:
0,P2D_TSID_ERR_UE_RSP_MSG_DISCD_SWITC
H:
0,AMRC_ON_122_AMR_HHO_ROLL_BACK_SWI
TCH:
0,RELOC_IN_RG_COMB_INDEX_ALLOC_SWIT
CH:0,SCM_CU_CROSS_SWITCH:
0,DRNC_HSPA_CM_OPT_SWITCH:
0,IUB_TRANSID_OPT_SWITCH:
0,L2_ENHENCE_RECFG_OPT_SWITCH:
0,ASYN_RL_REEST_OPT_SWITCH:
0,RNC_IMSI_HO_OPT_SWITCH:
0,IUR_PRIQUEUE_INFO_TO_MODIFY_OPT_SWI
TCH:
0,URA_PCH_LAC_RAC_CHG_NO_PAGING_SWI
TCH:0,PAGING_OVERLAP_CU_OPT_SWITCH:
0,SRVCC_RELOC_IN_USE_CS_KEY_SWITCH:
1,SOCKET_RECEIVE_DATA_CORRECT_SWITCH
:1,CU_PRI_OVERLAP_OTHER_PROC_SWITCH:
0,INTERRAT2U_INTEG_PROTECT_OPT_SWITC
H:0,CS_PAGING_OVERLAP_RRC_OPT_SWITCH:
0,INTRA_NODEB_RLCC_INIT_CAP_OPT_SWITC
H:0,DRNC_RL_PARA_UPT_OPT_SWITCH:1
13)EFACH_RRC_REG_CMP_SWITCH(E-FACH
RRC Registration Compatibility Switch)
Whether special UEs use the E-FACH to carry their
RRC CONNECTION SETUP messages when the cell
is enabled with E-FACH.
1: This switch is set to on. the RNC retransmits the
last RRC CONNECTION SETUP message on the E-
FACH if special users do not respond to the RRC
CONNECTION SETUP message on the FACH. If the
UE returns an RRC CONNECTION SETUP CMP
message, the UE stays in the CELL_DCH state during
data transmission.
0: This switch is set to off. no special processing is
performed on special users.
14)
P2D_TSID_ERR_UE_RSP_MSG_DISCD_SWITCH
(Discard Responses with Incorrect TRANSCIDs from
UEs During P2D)
Whether the RNC discards a RADIO BEARER
RECONFIGURATION COMPLETE message
received from a UE during P2D state transitions when
the value of the "RRC transaction identifier" IE in the
message is incorrect.
1: This switch is set to on. The RNC discards the
message and waits for the UE's response.
0: This switch is set to off. The RNC rolls back the
P2D state transition procedure.
15)
AMRC_ON_122_AMR_HHO_ROLL_BACK_SWIT
CH (HHO Rollback Switch for 12.2K AMR Services
with AMRC Enabled)
Whether the RNC performs rollback after 12.2 kbit/s
AMR-NB services experience hard handover failures
in the scenario where the narrowband AMRC function
takes effect.
0: This switch is set to off. The RNC does not perform
rollback after 12.2 kbit/s AMR-NB services
experience hard handover failures in the preceding
scenario.
1: This switch is set to on. The RNC performs
rollback after 12.2 kbit/s AMR-NB services
experience hard handover failures in the preceding
scenario.
16)RELOC_IN_RG_COMB_INDEX_ALLOC_SWIT
CH
29)INTERRAT2U_INTEG_PROTECT_OPT_SWITC
H(Integrity Protection Optimization Switch for
Incoming Inter-RAT Handovers)
Whether the optimized integrity protection function is
enabled for incoming L2U or G2U inter-RAT
handovers.
1: This switch is set to on. The integrity protection
function is immediately activated for SRB0 to SRB4
after the incoming L2U or G2U inter-RAT handover is
complete.
0: This switch is set to off. The integrity protection
function is activated only for SRB2 after the incoming
L2U or G2U inter-RAT handover is complete. The
integrity protection for other SRBs (SRB0, SRB1,
SRB3, and SRB4) is activated only after the UE sends
a message.
30)CS_PAGING_OVERLAP_RRC_OPT_SWITCH(
Optimize CS Paging During RRC Procedures)
Whether the RNC performs optimized processing
when a UE is paged in the CS domain during an RRC
connection setup procedure.
1: Indicates that this switch is set to ON. The RNC
performs optimized processing when a UE is paged in
the CS domain during an RRC connection setup
procedure.
0: Indicates that this switch is set to OFF. The access
delay of the CS paging procedure increases.
31)INTRA_NODEB_RLCC_INIT_CAP_OPT_SWIT
CH(Optimize the Rate upon NodeB RL Change for H
Services)
Whether the rate optimization policy is applied in the
scenario where the radio link (RL) for HSPA services
changes inside the NodeB.
1: This switch is set to on. The rate optimization
policy is applied in the scenario where the RL for
HSPA services changes inside the NodeB.
0: This switch is set to off. The rate optimization
policy is not applied in the scenario where the RL for
HSPA services changes inside the NodeB.
32)DRNC_RL_PARA_UPT_OPT_SWITCH(RL
Parameter Update Optimization Switch on RNC)
Whether the RL PARA UPT IND message over the
Iur interface can be correctly processed.
DRNC_RL_REEST_OPT_SWITCH,
URA2FACH_OVERLAP_CELLUPT_PROC_SWIT
CH,
RB_SETUP_F2D_USE_AM_RLC_SWITCH,
RB_RECFG_D2F_USE_AM_RLC_SWITCH,
RB_RECFG_F2D_USE_AM_RLC_SWITCH,
RRC_UE_USER_SMOOTH_OPT_SWITCH,
TRNC_LOAD_CTRL_SWITCH,
IU_SIG_REL_PCH_PAGING_SWITCH,
CPC_OPT_FOR_RLSETUP_SWITCH,
D2P_L2DEACT_FAIL_OPT_SWITCH,
EFACH_RRC_REG_CMP_SWITCH,
P2D_TSID_ERR_UE_RSP_MSG_DISCD_SWITCH,
AMRC_ON_122_AMR_HHO_ROLL_BACK_SWIT
CH,
RELOC_IN_RG_COMB_INDEX_ALLOC_SWITC
H,
SCM_CU_CROSS_SWITCH,
DRNC_HSPA_CM_OPT_SWITCH,
IUB_TRANSID_OPT_SWITCH,
L2_ENHENCE_RECFG_OPT_SWITCH,
ASYN_RL_REEST_OPT_SWITCH,
RNC_IMSI_HO_OPT_SWITCH,
IUR_PRIQUEUE_INFO_TO_MODIFY_OPT_SWIT
CH,
URA_PCH_LAC_RAC_CHG_NO_PAGING_SWIT
CH,
PAGING_OVERLAP_CU_OPT_SWITCH,
SRVCC_RELOC_IN_USE_CS_KEY_SWITCH,
SOCKET_RECEIVE_DATA_CORRECT_SWITCH,
CU_PRI_OVERLAP_OTHER_PROC_SWITCH,
INTERRAT2U_INTEG_PROTECT_OPT_SWITCH,
CS_PAGING_OVERLAP_RRC_OPT_SWITCH,
INTRA_NODEB_RLCC_INIT_CAP_OPT_SWITCH
,
DRNC_RL_PARA_UPT_OPT_SWITCH
Default Value:
RB_RLREEST_AM_TRB_RLC_REEST_SWITCH:
0,RB_SETUP_UM_TRB_RLREEST_ADJUD_OPT_
SWITCH:0,DRNC_RL_REEST_OPT_SWITCH:
1,URA2FACH_OVERLAP_CELLUPT_PROC_SWI
TCH:0,RB_SETUP_F2D_USE_AM_RLC_SWITCH:
0,RB_RECFG_D2F_USE_AM_RLC_SWITCH:
0,RB_RECFG_F2D_USE_AM_RLC_SWITCH:
0,RRC_UE_USER_SMOOTH_OPT_SWITCH:
1,TRNC_LOAD_CTRL_SWITCH:
0,IU_SIG_REL_PCH_PAGING_SWITCH:
0,CPC_OPT_FOR_RLSETUP_SWITCH:
1,D2P_L2DEACT_FAIL_OPT_SWITCH:
0,EFACH_RRC_REG_CMP_SWITCH:
0,P2D_TSID_ERR_UE_RSP_MSG_DISCD_SWITC
H:
0,AMRC_ON_122_AMR_HHO_ROLL_BACK_SWI
TCH:
0,RELOC_IN_RG_COMB_INDEX_ALLOC_SWIT
CH:0,SCM_CU_CROSS_SWITCH:
0,DRNC_HSPA_CM_OPT_SWITCH:
0,IUB_TRANSID_OPT_SWITCH:
0,L2_ENHENCE_RECFG_OPT_SWITCH:
0,ASYN_RL_REEST_OPT_SWITCH:
0,RNC_IMSI_HO_OPT_SWITCH:
0,IUR_PRIQUEUE_INFO_TO_MODIFY_OPT_SWI
TCH:
0,URA_PCH_LAC_RAC_CHG_NO_PAGING_SWI
TCH:0,PAGING_OVERLAP_CU_OPT_SWITCH:
0,SRVCC_RELOC_IN_USE_CS_KEY_SWITCH:
1,SOCKET_RECEIVE_DATA_CORRECT_SWITCH
:1,CU_PRI_OVERLAP_OTHER_PROC_SWITCH:
0,INTERRAT2U_INTEG_PROTECT_OPT_SWITC
H:0,CS_PAGING_OVERLAP_RRC_OPT_SWITCH:
0,INTRA_NODEB_RLCC_INIT_CAP_OPT_SWITC
H:0,DRNC_RL_PARA_UPT_OPT_SWITCH:1
McHsdp BSC690 SET None None Meaning: Whether the RNC reconfigures MC-HSDPA
aLteCM 0 UCMCF services as HSDPA services for UEs during the LTE
Permissi cell measurement in CM. If this parameter is set to
onInd FALSE, The RNC reconfigures MC-HSDPA services
as HSDPA services. If this parameter is set to TRUE,
The original algorithm applies.
GUI Value Range: FALSE(Forbidden), TRUE(Permit)
Unit: None
Actual Value Range:
FALSE,
TRUE
Default Value: TRUE(Permit)
McHsdp BSC691 SET None None Meaning: Whether the RNC reconfigures MC-HSDPA
aLteCM 0 UCMCF services as HSDPA services for UEs during the LTE
Permissi cell measurement in CM. If this parameter is set to
onInd FALSE, The RNC reconfigures MC-HSDPA services
as HSDPA services. If this parameter is set to TRUE,
The original algorithm applies.
GUI Value Range: FALSE(Forbidden), TRUE(Permit)
Unit: None
Actual Value Range:
FALSE,
TRUE
Default Value: TRUE(Permit)
PS_CM_COV_H2D_0K_SWITCH,
PS_CMACTIVE_PROCESS_OPT_SWITCH,
PS_CMTIMEOUT_UP_LIMIT_SWITCH,
PS_STREAM_IU_QOS_NEG_ENHANCE_SWITCH
, PS_STREAM_IU_QOS_RENEG_SWITCH,
PS_AMBR_ENABLE_SWITCH
Default Value:
PS_BE_EXTRA_LOW_RATE_ACCESS_SWITCH:
0,PS_BE_INIT_RATE_DYNAMIC_CFG_SWITCH:
0,PS_BE_IU_QOS_NEG_SWITCH:
0,PS_RAB_DOWNSIZING_SWITCH:
1,PS_STREAM_IU_QOS_NEG_SWITCH:
0,PS_BE_STRICT_IU_QOS_NEG_SWITCH:
0,HSPA_ADPTIVE_RATE_ALGO_SWITCH:
0,PS_CM_COV_H2D_0K_SWITCH:
0,PS_CMACTIVE_PROCESS_OPT_SWITCH:
0,PS_CMTIMEOUT_UP_LIMIT_SWITCH:
0,PS_STREAM_IU_QOS_NEG_ENHANCE_SWITC
H:0, PS_STREAM_IU_QOS_RENEG_SWITCH:1,
PS_AMBR_ENABLE_SWITCH:0
PS_CM_COV_H2D_0K_SWITCH,
PS_CMACTIVE_PROCESS_OPT_SWITCH,
PS_CMTIMEOUT_UP_LIMIT_SWITCH,
PS_STREAM_IU_QOS_NEG_ENHANCE_SWITCH
, PS_STREAM_IU_QOS_RENEG_SWITCH,
PS_AMBR_ENABLE_SWITCH
Default Value:
PS_BE_EXTRA_LOW_RATE_ACCESS_SWITCH:
0,PS_BE_INIT_RATE_DYNAMIC_CFG_SWITCH:
0,PS_BE_IU_QOS_NEG_SWITCH:
0,PS_RAB_DOWNSIZING_SWITCH:
1,PS_STREAM_IU_QOS_NEG_SWITCH:
0,PS_BE_STRICT_IU_QOS_NEG_SWITCH:
0,HSPA_ADPTIVE_RATE_ALGO_SWITCH:
0,PS_CM_COV_H2D_0K_SWITCH:
0,PS_CMACTIVE_PROCESS_OPT_SWITCH:
0,PS_CMTIMEOUT_UP_LIMIT_SWITCH:
0,PS_STREAM_IU_QOS_NEG_ENHANCE_SWITC
H:0, PS_STREAM_IU_QOS_RENEG_SWITCH:1,
PS_AMBR_ENABLE_SWITCH:0
UlLdrTr BSC690 ADD WRFD- Load Meaning: Threshold for triggering uplink LDR. If the
igThd 0 UCELL 020102 Measure ratio of the uplink load to the uplink capacity is higher
LDM WRFD- ment than or equal to this threshold for a duration longer
MOD 020103 Inter than that specified by the "UlLdTrnsHysTime"
UCELL Frequen parameter, uplink LDR (preliminary congestion state)
WRFD- is triggered and LDR actions are performed to reduce
LDM 020106 cy Load
Balance the cell load. The recommended value difference
between "UlLdrRelThd" and "UlLdrTrigThd" is
Load higher than 10% because the load fluctuates.
Reshuffl Otherwise, a cell frequently enters and leaves the
ing preliminary congestion state.
GUI Value Range: 0~100
Unit: %
Actual Value Range: 0~100
Default Value: 55
UlLdrTr BSC691 ADD WRFD- Load Meaning: Threshold for triggering uplink LDR. If the
igThd 0 UCELL 020102 Measure ratio of the uplink load to the uplink capacity is higher
LDM WRFD- ment than or equal to this threshold for a duration longer
MOD 020103 Inter than that specified by the "UlLdTrnsHysTime"
UCELL Frequen parameter, uplink LDR (preliminary congestion state)
WRFD- is triggered and LDR actions are performed to reduce
LDM 020106 cy Load
Balance the cell load. The recommended value difference
between "UlLdrRelThd" and "UlLdrTrigThd" is
Load higher than 10% because the load fluctuates.
Reshuffl Otherwise, a cell frequently enters and leaves the
ing preliminary congestion state.
GUI Value Range: 0~100
Unit: %
Actual Value Range: 0~100
Default Value: 55
DlLdrTr BSC690 ADD WRFD- Load Meaning: Threshold for triggering downlink LDR. If
igThd 0 UCELL 020102 Measure the ratio of the downlink load to the downlink
LDM WRFD- ment capacity is higher than or equal to this threshold for a
MOD 020103 Inter duration longer than that specified by the
UCELL Frequen "DlLdTrnsHysTime" parameter, downlink LDR
WRFD- (preliminary congestion state) is triggered and LDR
LDM 020117 cy Load
Balance actions are performed to reduce the cell load. The
WRFD- recommended value difference between
020106 Multi- "DlLdrRelThd" and "DlLdrTrigThd" is higher than
Carrier 10% because the load fluctuates. Otherwise, a cell
WRFD- Switch
020122 frequently enters and leaves the preliminary
off congestion state.
Based
on GUI Value Range: 0~100
Traffic Unit: %
Load Actual Value Range: 0~100
Load Default Value: 70
Reshuffl
ing
Multi-
Carrier
Switch
off
Based
on QoS
DlLdrTr BSC691 ADD WRFD- Load Meaning: Threshold for triggering downlink LDR. If
igThd 0 UCELL 020102 Measure the ratio of the downlink load to the downlink
LDM WRFD- ment capacity is higher than or equal to this threshold for a
MOD 020103 Inter duration longer than that specified by the
UCELL Frequen "DlLdTrnsHysTime" parameter, downlink LDR
WRFD- (preliminary congestion state) is triggered and LDR
LDM 020117 cy Load
Balance actions are performed to reduce the cell load. The
WRFD- recommended value difference between
020106 Multi- "DlLdrRelThd" and "DlLdrTrigThd" is higher than
Carrier 10% because the load fluctuates. Otherwise, a cell
WRFD- Switch
020122 frequently enters and leaves the preliminary
off congestion state.
Based
on GUI Value Range: 0~100
Traffic Unit: %
Load Actual Value Range: 0~100
Load Default Value: 70
Reshuffl
ing
Multi-
Carrier
Switch
off
Based
on QoS
18 Counters
19 Glossary
20 Reference Documents