Documente Academic
Documente Profesional
Documente Cultură
Analysis Report
Method C:\CAMAG\winCATS\Data\ayu-tlc\aflatoksin yanita utama.cme
Created by universitas indonesia 30 Juli 2007 13:53:27
Last modified by universitas indonesia 30 Juli 2007 14:09:59
SOP document
Validated Design
Description :
Stationary phase
Executed by universitas indonesia 15 Juni 2014 10:41:11
Plate size (X x Y) 20,0 x 10,0 cm
Material TLC plates silica gel 60 F 254
Manufacturer E. MERCK KGaA
Batch
GLP code
Pre-washing Yes
Mode
Solvent name sikloheksan-toluen-dietilamin (65:25:10)
Manufacturer E. MERCK KgaA
Batch
Drying device Oven
Temperature 120 C
Time 20 Minutes
Modification No
Definitions - Quantification
Executed by universitas indonesia 30 Juli 2007 14:09:59
Calibration parameters
Calibration mode Multi level
Statistics mode CV
Evaluation mode Peak Height & Area
Samples
Sample ID: 20
Sample ID: 40
Sample ID: 60
Sample ID: 80
Sample ID: 100
Sample ID: 120
Sample ID: 140
Sample ID: 160
Sample ID: 2
Sample ID: 4
Sample ID: 6
Sample ID: 8
Sample ID: 10
Sample ID: 12
Sample ID: 14
Sample ID: 16
Window Batch Product
Substance name Rf size Regression Deviation Purity Manufacturer number Expiry date number
Standards absolute
Standard level1
Standard level2
Substance Amount/fraction
aflatoksin b1 0,040 ng
aflatoksin B1 0,040 ng
Standard level3
Substance Amount/fraction
aflatoksin b1 0,060 ng
aflatoksin B1 0,060 ng
Standard level4
Substance Amount/fraction
aflatoksin b1 0,080 ng
aflatoksin B1 0,080 ng
Standard level5
Substance Amount/fraction
aflatoksin b1 0,100 ng
aflatoksin B1 0,100 ng
Standard level6
Substance Amount/fraction
aflatoksin b1 0,120 ng
aflatoksin B1 0,120 ng
Standard level7
Substance Amount/fraction
aflatoksin b1 0,140 ng
aflatoksin B1 0,140 ng
Standard level8
Substance Amount/fraction
aflatoksin b1 0,160 ng
aflatoksin B1 0,160 ng
Measurement Table
Wavelength 354
Lamp Hg
Measurement Type Remission
Measurement Mode Fluorescence
Optical filter K400
Detector mode Automatic
PM high voltage 194 V
Detector properties
Y-position for 0 adjust 5,0 mm
Track # for 0 adjust 0
Analog Offset 10%
Sensitivity Automatic (219)
Integration
Properties
Data filtering Savitsky-Golay 7
Baseline correction Lowest Slope
Peak threshold min. slope 5
Peak threshold min. height 10 AU
Peak threshold min. area 50
Peak threshold max. height 990 AU
Track start position 38,6 mm
Track end position 43,7 mm
Display scaling Automatic
All tracks at Wavelength
500
[ AU ]
400
350
300
250
200
150
100 200
50
0 [ mm ]
0,45
0,46 100
0,47
0,48 50
0,49
[ Rf ]
0,51 0
50 250
00 200
50 150
00 100
50 50
0 0
-0,07 0,14 0,34 0,54 0,73 0,94 -0,07 0,14 0,34 0,54 0,73 0,94