DISTRIBUTION 8146/5-6 Series DISCONNECTS 8146/5 Series Breaker Panelboards DISTRIBUTION

DIMENSIONS BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS

.28" Breaker Panels


.36" .64" 7mm
9mm 16mm Features:

175 mm
170mm
118 mm
Wide variety of Flameproof

9 mm

227 mm

241mm
.36"

7.0"
184mm
6.7"
4.7"

9.0"

9.5"
7.3"
branch circuit breakers for
Zone 1 & Division 2 to UL
6.0"
.28" 489 & CSA C22.2 No. 5
7mm 5.2"
152 mm 131mm 6.0" .28" Thermal-magnetic
(552) 152 mm 7mm
6.7" 6.7" branch circuit breaker
170mm 170mm protection, 40A max.
5.2"
7.3" 131mm Mounted under hinged
184mm (562)
window flaps for easy
actuation.
16A DISCONNECT SWITCH 32A DISCONNECT SWITCH
Shunt trips (optional).
8146/5-602 Series 8146/5-604 Series
Lockout on breaker and
window flap.
Line and load side
factory wired to
increased safety
.28" .64" terminals, ready for
7mm 16mm
field connections
.36"
Flameproof main discon-
288.5mm

.64"
9 mm

9mm nect switches 125A max.


.36"
11.4"

16mm
with lockout provision
340.5 mm

(optional).
13.4"

695.5mm
629.5 mm

681.5 mm
288.5mm

27.4"
34.8"

26.8"
354.5mm
11.4"

FRP increased safety


14.0"

enclosures
288.5 mm
11.4"

Suitable for wet and


corrosive locations
12.7" .28" Impact resistant
322.5 mm 7mm 5.9"
13.4" 150mm Light weight
340.5mm (583)
.28" Wall mounting frames
14.0" 12.7"
354.5 mm 322.5mm
7mm
7.5" available
13.4" 190mm Flange Plates can be
340.0mm (595)
63A DISCONNECT SWITCH fitted with Increased
14.0"
8146/5-606 Series 354.5mm Safety certified conduit
hubs or cable glands
125A DISCONNECT SWITCH (see section J).
8146/5-609 Series No seals required for
Division 2 application.

H4
INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357 EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
H3
DISTRIBUTION 8146/5 Series Breaker Panelboards 8146/5 Series Breaker Panelboards DISTRIBUTION

BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS

Quick and Easy Access to Breaker

Modular increased safety enclosures made


of FRP for indoors and outdoors, damp, wet
CLASSIFICATIONS corrosive and hazardous locations Spring Loaded-Hinged Window
NEC- Class I, Zone 1 AEx de IIC T5 or T6 Flaps with Lockout Provision
Class I, Division 2, Groups A,B,C&D

File No. 3031420 Class 1, Zone 1


Class 1, Division 2
Breakers Now Available
CEC- Class I, Zone 1 Ex de IIC T5 or T6
up to 40 amps
Class I, Division 2, Groups A,B,C&D
Environmental Protection
Type 3, 4, 4X; IP66
Cover Removable
Ambient Temperature Range Only in the OFF Conduit hubs or cable glands can be installed with back-up Springloaded - hinged window flaps allow easy
+40C (+104F) Max. Position Flameproof Main bonding plates, as shown above or with increased safety viewing and quick access to breakers without
20C (4F) Min. Disconnect Switch grounding locknuts which are interconnected with green opening the enclosure.
jumper wire and also connected to the ground system.
Applications Individual breakers and the window flaps can
The series 8146/5 Breaker For details see page C3, and for spacing see page C4. be padlocked.
Panelboards provide a switching sys-
tem and short circuit protection for Max. Number of Ex MCBs Ex MCBs
feeder and branch circuits to control
Under One Window Flap
either resistive or inductive loads.
Applications would be heating, 6 1 pole
lighting, heat tracing and motor
circuits in refineries, chemical and 4 2 pole
petrochemical plants and other 3 3 pole
process industries. They are avail-
able with or without Main
Disconnect. To provide adequate
short circuit protection, properly
sized Class J fuses must be installed
in the circuit upstream for protection
of the Main Disconnect Switch.

Disconnect
Handle with Technical Data of Main Disconnect Switches
Lockout Type Voltage ac Amperage Back-Up Fuse J
Provision Increased
Safety 8543/1 600 40 60 A max.
Line-up 8543/2 600 63 100 A max.
Terminals
8548/1 600 125 200 A max.
to Connect
Field Wiring
The Disconnect Switches are made of FRP to safely con-
tain the pressure generated by an internal explosion.
Ample
Space for
Field Wiring
Optional auxiliary contacts are available.

Flange Plates and Sealing Frames


allow for Coupling of Individual
Enclosures to expand the Units Increased Safety Conduit Hubs

H5 H6
EXPLOSION PROTECTION by R. STAHL 1-800-782-4357 EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
DISTRIBUTION 8146/5 Series Breaker Panelboards 8146/5 Series Breaker Panelboards DISTRIBUTION

BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS

Quick and Easy Access to Breaker

Modular increased safety enclosures made


of FRP for indoors and outdoors, damp, wet
CLASSIFICATIONS corrosive and hazardous locations Spring Loaded-Hinged Window
NEC- Class I, Zone 1 AEx de IIC T5 or T6 Flaps with Lockout Provision
Class I, Division 2, Groups A,B,C&D

File No. 3031420 Class 1, Zone 1


Class 1, Division 2
Breakers Now Available
CEC- Class I, Zone 1 Ex de IIC T5 or T6
up to 40 amps
Class I, Division 2, Groups A,B,C&D
Environmental Protection
Type 3, 4, 4X; IP66
Cover Removable
Ambient Temperature Range Only in the OFF Conduit hubs or cable glands can be installed with back-up Springloaded - hinged window flaps allow easy
+40C (+104F) Max. Position Flameproof Main bonding plates, as shown above or with increased safety viewing and quick access to breakers without
20C (4F) Min. Disconnect Switch grounding locknuts which are interconnected with green opening the enclosure.
jumper wire and also connected to the ground system.
Applications Individual breakers and the window flaps can
The series 8146/5 Breaker For details see page C3, and for spacing see page C4. be padlocked.
Panelboards provide a switching sys-
tem and short circuit protection for Max. Number of Ex MCBs Ex MCBs
feeder and branch circuits to control
Under One Window Flap
either resistive or inductive loads.
Applications would be heating, 6 1 pole
lighting, heat tracing and motor
circuits in refineries, chemical and 4 2 pole
petrochemical plants and other 3 3 pole
process industries. They are avail-
able with or without Main
Disconnect. To provide adequate
short circuit protection, properly
sized Class J fuses must be installed
in the circuit upstream for protection
of the Main Disconnect Switch.

Disconnect
Handle with Technical Data of Main Disconnect Switches
Lockout Type Voltage ac Amperage Back-Up Fuse J
Provision Increased
Safety 8543/1 600 40 60 A max.
Line-up 8543/2 600 63 100 A max.
Terminals
8548/1 600 125 200 A max.
to Connect
Field Wiring
The Disconnect Switches are made of FRP to safely con-
tain the pressure generated by an internal explosion.
Ample
Space for
Field Wiring
Optional auxiliary contacts are available.

Flange Plates and Sealing Frames


allow for Coupling of Individual
Enclosures to expand the Units Increased Safety Conduit Hubs

H5 H6
EXPLOSION PROTECTION by R. STAHL 1-800-782-4357 EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
DISTRIBUTION 8146/5 Series Breaker Panelboards 8298 Series Support Frame System DISTRIBUTION

THERMAL-MAGNETIC Ex MCBs TO UL 489 & CSA C22.2 No.5 FOR BREAKER PANELS SERIES 8146/5

1 Pole Ex MCB, 8562/51 Series


Amp Catalog Number
Rating at
Ta = 25C 120/240 Vac, 10 kAIC 277 Vac, 10 kAIC 60 V, 0-60 Hz, 5kAIC
0.2 8562/51-1420-002 8562/51-1430-002 N/A
CLASSIFICATIONS of Breaker 0.3 8562/51-1420-003 8562/51-1430-003 N/A 1. Vertical Supports
NEC
0.5 8562/51-1420-005 8562/51-1430-005 N/A
Class I, Zone 1, AEx de IIC T5 or T6 2. Horizontal Supports
Class I, Div. 2, Groups A, B, C & D 0.75 8562/51-1420-008 8562/51-1430-008 N/A
CEC 1.0 8562/51-1420-010 8562/51-1430-010 8562/51-1410-010 3. Bracket for Roof Attachment
Ex de IIC T5 or T6
1.6 8562/51-1420-016 8562/51-1430-016 8562/51-1410-016 - To secure roof
Class I, Div. 2, per: CEC J18-150 (C) - Can be used to mount a
2 8562/51-1420-020 8562/51-1430-020 8562/51-1410-020
Certified File No. 1850696
luminaire.
3 8562/51-1420-030 8562/51-1430-030 8562/51-1410-030
See Catalog Section B.
File No. 3033692
4 8562/51-1420-040 8562/51-1430-040 8562/51-1410-040
5 8562/51-1420-050 8562/51-1430-050 N/A 4. Roof
FEATURES 6 8562/51-1420-060 8562/51-1430-060 8562/51-1410-060 - For additional protection
Method of Protection: Flameproof 8 8562/51-1420-080 8562/51-1430-080 8562/51-1410-080 of the breaker panel from
1, 2 and 3 Pole with Thermal - the elements.
10 8562/51-1420-100 8562/51-1430-100 8562/51-1410-100
Magnetic Branch Circuit Protection
13 N/A N/A 8562/51-1410-130 5. Brackets
Design to UL 489 and - End piece for transportation
15 8562/51-1420-150 8562/51-1430-150 N/A
CSA-C22.2 No. 5-02
16 8562/51-1420-160 8562/51-1430-160 8562/51-1410-160 and wall mounting. Possible
Options: Shunt Trip
20 8562/51-1420-200 8562/51-1430-200 8562/51-1410-200 on top and bottom.
Breakers are not temperature 25 8562/51-1420-250 8562/51-1430-250 8562/51-1410-250 6. Fixing Angle Brackets
compensated
30 8562/51-1420-300 8562/51-1610-300 N/A - For wall mounting (on left
32 8562/51-1420-320 8562/51-1610-320 N/A and right side)
40 8562/51-1420-400 8562/51-1610-400 N/A
7. Bonding terminal
8. Triangle Support
- Free standing
2 Pole Ex MCB, 8562/52 Series 3 Pole Ex MCB, 8562/53 Series
- Can be fixed to the floor
Amp Catalog Number Amp Catalog Number
Rating at Rating at
Ta = 25C 120/240 Vac, 10 kAIC 480Y/ 277 Vac, 10 kAIC Ta = 25C 240 Vac, 10 kAIC 480Y/ 277 Vac, 10 kAIC
0.2 8562/52-2420-002 8562/52-2430-002 0.2 8562/53-3420-002 8562/53-3430-002
0.3 8562/52-2420-003 8562/52-2430-003 0.3 8562/53-3420-003 8562/53-3430-003
0.5 8562/52-2420-005 8562/52-2430-005 0.5 8562/53-3420-005 8562/53-3430-005
0.75 8562/52-2420-008 8562/52-2430-008 0.75 8562/53-3420-008 8562/53-3430-008 Wall Mounting Frame for Breaker Panel
1.0 8562/52-2420-010 8562/52-2430-010 1.0 8562/53-3420-010 8562/53-3430-010 shown on page H5.
1.6 8562/52-2420-016 8562/52-2430-016 1.6 8562/53-3420-016 8562/53-3430-016
2 8562/52-2420-020 8562/52-2430-020 2 8562/53-3420-020 8562/53-3430-020
3 8562/52-2420-030 8562/52-2430-030 3 8562/53-3420-030 8562/53-3430-030
4 8562/52-2420-040 8562/52-2430-040 4 8562/53-3420-040 8562/53-3430-040
5 8562/52-2420-050 8562/52-2430-050 5 8562/53-3420-050 8562/53-3430-050
6 8562/52-2420-060 8562/52-2430-060 6 8562/53-3420-060 8562/53-3430-060
8 8562/52-2420-080 8562/52-2430-080 8 8562/53-3420-080 8562/53-3430-080 R. STAHL INC. would welcome the
10 8562/52-2420-100 8562/52-2430-100 10 8562/53-3420-100 8562/53-3430-100 opportunity to quote custom
15 8562/52-2420-150 8562/52-2430-150 15 8562/53-3420-150 8562/53-3430-150 designed breaker panels. Contact
16 8562/52-2420-160 8562/52-2430-160 16 8562/53-3420-160 8562/53-3430-160
our engineering department with
your specific requirements
20 8562/52-2420-200 8562/52-2430-200 20 8562/53-3420-200 8562/53-3430-200
25 8562/52-2420-250 8562/52-2430-250 25 8562/53-3420-250 8562/53-3430-250
30 8562/52-2420-300 8562/52-2610-300 30 8562/53-3420-300 8562/53-3610-300
32 8562/52-2420-320 8562/52-2610-320 32 8562/53-3420-320 8562/53-3610-320
40 8562/52-2420-400 8562/52-2610-400 40 8562/53-3420-400 8562/53-3610-400

H7 H8
EXPLOSION PROTECTION by R. STAHL 1-800-782-4357 EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
DISTRIBUTION 8146/5 Series Breaker Panelboards 8298 Series Support Frame System DISTRIBUTION

THERMAL-MAGNETIC Ex MCBs TO UL 489 & CSA C22.2 No.5 FOR BREAKER PANELS SERIES 8146/5

1 Pole Ex MCB, 8562/51 Series


Amp Catalog Number
Rating at
Ta = 25C 120/240 Vac, 10 kAIC 277 Vac, 10 kAIC 60 V, 0-60 Hz, 5kAIC
0.2 8562/51-1420-002 8562/51-1430-002 N/A
CLASSIFICATIONS of Breaker 0.3 8562/51-1420-003 8562/51-1430-003 N/A 1. Vertical Supports
NEC
0.5 8562/51-1420-005 8562/51-1430-005 N/A
Class I, Zone 1, AEx de IIC T5 or T6 2. Horizontal Supports
Class I, Div. 2, Groups A, B, C & D 0.75 8562/51-1420-008 8562/51-1430-008 N/A
CEC 1.0 8562/51-1420-010 8562/51-1430-010 8562/51-1410-010 3. Bracket for Roof Attachment
Ex de IIC T5 or T6
1.6 8562/51-1420-016 8562/51-1430-016 8562/51-1410-016 - To secure roof
Class I, Div. 2, per: CEC J18-150 (C) - Can be used to mount a
2 8562/51-1420-020 8562/51-1430-020 8562/51-1410-020
Certified File No. 1850696
luminaire.
3 8562/51-1420-030 8562/51-1430-030 8562/51-1410-030
See Catalog Section B.
File No. 3033692
4 8562/51-1420-040 8562/51-1430-040 8562/51-1410-040
5 8562/51-1420-050 8562/51-1430-050 N/A 4. Roof
FEATURES 6 8562/51-1420-060 8562/51-1430-060 8562/51-1410-060 - For additional protection
Method of Protection: Flameproof 8 8562/51-1420-080 8562/51-1430-080 8562/51-1410-080 of the breaker panel from
1, 2 and 3 Pole with Thermal - the elements.
10 8562/51-1420-100 8562/51-1430-100 8562/51-1410-100
Magnetic Branch Circuit Protection
13 N/A N/A 8562/51-1410-130 5. Brackets
Design to UL 489 and - End piece for transportation
15 8562/51-1420-150 8562/51-1430-150 N/A
CSA-C22.2 No. 5-02
16 8562/51-1420-160 8562/51-1430-160 8562/51-1410-160 and wall mounting. Possible
Options: Shunt Trip
20 8562/51-1420-200 8562/51-1430-200 8562/51-1410-200 on top and bottom.
Breakers are not temperature 25 8562/51-1420-250 8562/51-1430-250 8562/51-1410-250 6. Fixing Angle Brackets
compensated
30 8562/51-1420-300 8562/51-1610-300 N/A - For wall mounting (on left
32 8562/51-1420-320 8562/51-1610-320 N/A and right side)
40 8562/51-1420-400 8562/51-1610-400 N/A
7. Bonding terminal
8. Triangle Support
- Free standing
2 Pole Ex MCB, 8562/52 Series 3 Pole Ex MCB, 8562/53 Series
- Can be fixed to the floor
Amp Catalog Number Amp Catalog Number
Rating at Rating at
Ta = 25C 120/240 Vac, 10 kAIC 480Y/ 277 Vac, 10 kAIC Ta = 25C 240 Vac, 10 kAIC 480Y/ 277 Vac, 10 kAIC
0.2 8562/52-2420-002 8562/52-2430-002 0.2 8562/53-3420-002 8562/53-3430-002
0.3 8562/52-2420-003 8562/52-2430-003 0.3 8562/53-3420-003 8562/53-3430-003
0.5 8562/52-2420-005 8562/52-2430-005 0.5 8562/53-3420-005 8562/53-3430-005
0.75 8562/52-2420-008 8562/52-2430-008 0.75 8562/53-3420-008 8562/53-3430-008 Wall Mounting Frame for Breaker Panel
1.0 8562/52-2420-010 8562/52-2430-010 1.0 8562/53-3420-010 8562/53-3430-010 shown on page H5.
1.6 8562/52-2420-016 8562/52-2430-016 1.6 8562/53-3420-016 8562/53-3430-016
2 8562/52-2420-020 8562/52-2430-020 2 8562/53-3420-020 8562/53-3430-020
3 8562/52-2420-030 8562/52-2430-030 3 8562/53-3420-030 8562/53-3430-030
4 8562/52-2420-040 8562/52-2430-040 4 8562/53-3420-040 8562/53-3430-040
5 8562/52-2420-050 8562/52-2430-050 5 8562/53-3420-050 8562/53-3430-050
6 8562/52-2420-060 8562/52-2430-060 6 8562/53-3420-060 8562/53-3430-060
8 8562/52-2420-080 8562/52-2430-080 8 8562/53-3420-080 8562/53-3430-080 R. STAHL INC. would welcome the
10 8562/52-2420-100 8562/52-2430-100 10 8562/53-3420-100 8562/53-3430-100 opportunity to quote custom
15 8562/52-2420-150 8562/52-2430-150 15 8562/53-3420-150 8562/53-3430-150 designed breaker panels. Contact
16 8562/52-2420-160 8562/52-2430-160 16 8562/53-3420-160 8562/53-3430-160
our engineering department with
your specific requirements
20 8562/52-2420-200 8562/52-2430-200 20 8562/53-3420-200 8562/53-3430-200
25 8562/52-2420-250 8562/52-2430-250 25 8562/53-3420-250 8562/53-3430-250
30 8562/52-2420-300 8562/52-2610-300 30 8562/53-3420-300 8562/53-3610-300
32 8562/52-2420-320 8562/52-2610-320 32 8562/53-3420-320 8562/53-3610-320
40 8562/52-2420-400 8562/52-2610-400 40 8562/53-3420-400 8562/53-3610-400

H7 H8
EXPLOSION PROTECTION by R. STAHL 1-800-782-4357 EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
DISTRIBUTION 8146/5 Series Breaker Panelboards Broz Hazardous Classified Panelboards XXXXX
DISTRIBUTION
DIMENSIONS

Applications:

For hazardous classified locations


due to explosive gas atmospheres
CLASSIFICATIONS of Breaker
Petroleum refineries, oilsands, NEC
Class I, Zone 2 Group IIC, T4
chemical and petrochemical facilities
Class I, Div. 2, Groups B, C & D, T4
Terminals with indoor or outdoor processes CEC
Class I, Zone 2 Group IIC, T4
Applications requiring overcurrent Class I, Div. 2 Groups B, C & D, T4
and short circuit protection for
Environmental Protection
power, lighting, and heat tracing. Type 3, 4, 4X; IP66

SAVE INSTALATION TIM


Layout without Avoid removing dozens of bolts as with
Disconnect Switch traditional explosion proof ferrous systems.
Features: No expensive seals
No drill and tapping enclosures
Extremely easy to maintain. Simply Light weight design (No need for
enter the enclosure by turning the 316L stainless steel hardware provid expensive lift equipment)

door handle and gaining access to ed for all external components to


Terminals the breaker compartment. There is prevent corrosion. SAVE ON MAINTENANCE
no need to remove dozens of bolts NEMA 4X padlocking 316L SS han Window doors allow easy viewing.

to change a breaker. dle and internal heavy duty 3 point


Lightweight and easy to install com latching system combine security LAST LONGER
Layout without
and a watertight seal with ease of Stainless Steel, and fiberglass options
Disconnect Switch pared to traditional explosion proof
outlast traditional cast aluminum in
construction. Expensive lift equip access
corrosive environments
ment often not needed. No cable or conduit seals are
Window doors allow easy viewing of required, allowing for fast installation WORK SAFER
breaker positions without opening and lowering overall installed cost. Finger safe construction prevents
Standard bottom entry reduces risk accidental contact with live parts.
the enclosure.
Padlockable breakers
R. STAHL 8562 series circuit break of moisture ingress. (Top entry is
ers with 10KA interrupt ratings meet available)
all necessary North American Finger safe construction & UL508A
approvals. approved bus system prevents acci
8562 series breakers are padlock dental contact with live parts.
able in the off position. Enclosures are easily punched in
Seamless foam in place gaskets the field. No drill and tapping
exclude contaminants and liquids required.
8146/5 Panelboard Dimensions
ensuring long life of interior compo
Callouts mm / inches nents.
A 340.50 / 13.41 Available in brushed stainless steel,
B 681.50 / 26.83
epoxy powder coated, and fiberglass
C 682.00 / 26.85
D 1236.00 / 48.66 for maximum corrosion resistance.
E 684.00 / 26.93
F 1023.00 / 40.28
G 1578.00 / 62.13

H9 H10
EXPLOSION PROTECTION by R. STAHL 1-800-782-4357 EXPLOSION PROTECTION by R. STAHL 1-800-782-4357