Sunteți pe pagina 1din 35

ReportIndex

Input File
Input Reprint
Solution History
Node Summary
Link Summary
Device Summary
Structure Summary
Velocity Summary
Results Summary
Flash Summary
Pump Summary
L002
Index

Input File: C:\USERS\USER\DESKTOP\ROMMEL\RUN2

$ SIMSCI PIPEPHASE Version 9.1 keyword file...


$
$General Data Section
$
TITLE PROBLEM=RUM1, DATE=11/16/17
$
$
DIMENSION Metric
$
CALCULATION NETWORK, Compositional, PRANDTL
$
DEFAULT IDPIPE=102.26035, IDTUBING=102.26035, IDRISER=102.26035, *
IDANNULUS=154.05092, HAUSEN
$
PRINT INPUT=FULL, DEVICE=FULL, PLOT=FULL, *
PROPERTY=FULL, MAP=TAITEL, MERGESUB, *
DATABASE=FULL, SIMULATOR=PART
$
SEGMENT AUTO=OFF, DLHORIZ(M)=609.59967, *
DLVERT(M)=152.39992
$
$Component Data Section
$
COMPONENT DATA
$
LIBID 1, H2O
$
PHASE VL=1,1

$
$Network Data Section
$
NETWORK DATA
$
SOLUTION PBALANCE, FLOWAL=2, STEP=1
$
TOLERANCE PRESSURE=6.895e-003
$
$Thermodynamic Data Section
$
THERMODYNAMIC DATA
$
METHOD SET=SET01, SYSTEM=SRK
$
WATER PROPERTY=Super
$
KVALUE BANK=SimSci
$
$PVT Data Section
$
PVT PROPERTY DATA
$
SET SETNO=1, SET=SET01
$
$Structure Data Section
$
STRUCTURE DATA
$
SOURCE NAME=S001, IDNAME=S001, PRIORITY=0, *
PRES=1.11, TEMP=25, RATE(ESTI,LV)=20.83, *
XCORD=-255, YCORD=117, *
COMP(M)=1, 100
$
SINK NAME=D001, IDNAME=D001, PRES(ESTI)=3.2, *
RATE=20830, XCORD=309, YCORD=63
$
$
$
LINK NAME=L002, FROM=S001, TO=D001, *
IDNAME=L002, IDFROM=S001, IDTO=D001, *
XCOR=202,76,-72, YCOR=110,136,147
PIPE NAME=P002, LENGTH=2, ECHG=2, *
ID=50, U=4.88243
BEND NAME=B001, ID=50, KMUL=30, *
ROUGH(MM)=0.0457
PIPE NAME=P003, LENGTH=1, ID=50, *
U=4.88243
PUMP NAME=P004, RPMC=3500, *
CRV1=15, 36, 61 / 20, 31, 66 / *
25, 27, 64
PIPE NAME=P005, LENGTH=25.31, ECHG=4, *
ID=40, U=4.88243
BEND NAME=B002, ID=40, KMUL=16, *
ROUGH(MM)=0.0457
PIPE NAME=P007, LENGTH=2, ECHG=2, *
ID=40, U=4.88243
BEND NAME=B003, ID=40, KMUL=30, *
ROUGH(MM)=0.0457
$
$ End of keyword file...
$
END
Index

Input Data

*** WARNING *****


PRESS: ESTIMATE AND FLOW DIRECTION INCONSISTENT
FOR FOLLOWING LINKS
LINK FROM NODE PRESSURE TO NODE PRESSURE
1 S001 16.1 D001 46.4

CALCULATION OPTIONS

RUN TYPE........ NETWORK


FLUID TYPE...... COMPOSITIONAL

DIMENSIONAL UNITS - METRIC

TEMPERATURE..... DEG C PRESSURE........ BAR


MOLAR RATE...... KG-M/HR WEIGHT RATE..... KG/HR
LIQUID RATE..... M3/HR VAPOR RATE...... MM M3/HR
COARSE LENGTH... M FINE LENGTH..... MM
DENSITY/GRAVITY. KG/M3 VISCOSITY....... CP
DUTY............ MM KCAL/HR POWER........... KW
VELOCITY........ KM/HR

DEFAULTS

FLOW EFFICIENCY............ 100.00 PERCENT


HAZEN-WILLIAMS COEFF....... 150.00
ROUGHNESS.................. 0.04572 MM
AMBIENT TEMPERATURE........ 26.67 DEG C
TEMPERATURE GRADIENT....... 1.82 DEG C/100 M
PIPE U-FACTOR.............. 4.882 KCAL/HR-M2-C
RISER U-FACTOR............. 4.882 KCAL/HR-M2-C
TUBING U-FACTOR............ 4.882 KCAL/HR-M2-C
ANNULUS U-FACTOR........... 4.882 KCAL/HR-M2-C
INSIDE DIAMETER - PIPE..... 102.260 MM
INSIDE DIAMETER - RISER.... 102.260 MM
INSIDE DIAMETER - TUBING... 102.260 MM
INSIDE DIAMETER - ANNULUS.. 154.051 MM
LAMINAR INSIDE FILM COEFF.. HAUSEN

FLOW CODES
PIPE FLOW CODE IS BEGGS-BRILL (MOODY)
REYNOLDS NUMBER(LAMINAR)..... 3000.0000
RISER FLOW CODE IS BEGGS-BRILL (MOODY)
TUBING FLOW CODE IS BEGGS-BRILL (MOODY)
ANNULUS FLOW CODE IS BEGGS-BRILL (MOODY)

BASE CONDITIONS

STANDARD TEMPERATURE....... 15.56 DEG C


STANDARD PRESSURE.......... 1.013 BAR

PRINT OPTIONS

INPUT........... GENERAL ASSAY COMPONENT


PVT FLOW TABLE METHOD
SOURCE STRUCTURE W ANALYSIS
GAS LIFT CASE STUDY
CONNECT......... PLOT
PVTGEN.......... NONE
SUMMARY......... BOTH
DEVICE.......... FULL
MAP............. TAITEL-DUKLER-BARNEA
PROPERTY........ FULL
FLASH........... SUMMARY
STREAM.......... SUMMARY
MERGED SUBNETWORKS REQUESTED

SEGMENTATION OPTIONS

LENGTH CHANGE - HORIZONTAL....... 609.6 M


VERTICAL......... 152.4 M
MAXIMUM NUMBER OF SEGMENTS....... 20

SOLUTION METHODS/TOLERANCES

NETWORK SOLUTION METHOD IS PBAL


MAXIMUM ITERATIONS..................... 20
MAXIMUM NUMBER OF INTERVAL HALVINGS.... 3
ABSOLUTE PRESSURE TOLERANCE............ 0.007 BAR
RATE PERTURBATION...................... 0.010000
METHOD OF INITIAL SOLUTION ESTIMATION.. FLOW = 2
ZERO FLOW IN CHECK VALVES.............. OFF
CHOKE CRITICAL FLOW MODEL (FORTUNATI) . EXPONENTIAL
NEW ACCELERATION OPTION IS............. OFF

SOURCE S001

(S001)
PHASE IS MIXED
THIS SOURCE IS ON
ESTIMATED RATE............ 20.8300 M3/HR
PRESSURE.................. 1.1100 BAR
TEMPERATURE............... 25.00 DEG C

LINK L002

LINK IS FROM "S001 " TO "D001 "


"L002" FROM "S001" TO "D001"

DEVICE SA001, P002, IS A PIPE


FLOW CODE IS BEGGS-BRILL (MOODY)
INSIDE DIAMETER.............. 50.0000 MM
LENGTH....................... 2.0 M
ELEVATION CHANGE............. 2.0 M
FLOW EFFICIENCY.............. 100.00 PERCENT
HEAT LOSS COEFFICIENT........ 4.88243 KCAL/HR-M2-C
ROUGHNESS.................... 0.04572 MM
AMBIENT TEMPERATURE.......... 26.67 DEG C

DEVICE WA002, B001, IS A BEND


FLOW CODE IS CHISHOLM
THIS IS A STANDARD BEND
PIPE INSIDE DIAMETER......... 50.00 MM
LAMDA (CHISHOLM PARAMETER)... 1.00000
C2 (CHISHOLM PARAMETER)...... 4.35000
RESISTANCE COEFF: MULTPLIER.. 30.0000
ROUGHNESS.................... 0.04570 MM
NUMBER OF DEVICES............ 1.

DEVICE SA003, P003, IS A PIPE


FLOW CODE IS BEGGS-BRILL (MOODY)
INSIDE DIAMETER.............. 50.0000 MM
LENGTH....................... 1.0 M
ELEVATION CHANGE............. 0.0 M
FLOW EFFICIENCY.............. 100.00 PERCENT
HEAT LOSS COEFFICIENT........ 4.88243 KCAL/HR-M2-C
ROUGHNESS.................... 0.04572 MM
AMBIENT TEMPERATURE.......... 26.67 DEG C

DEVICE SA004, P004, IS A PUMP


THIS IS A SURFACE DEVICE
NUMBER OF STAGES............. 1
PUMP HEAD CURVE
FLOWRATE, DIFFERENTIAL EFFICIENCY,
M3/HR HEAD, M HEAD PERCENT
----------- ------------- -----------
1 15.0000 36.0 61.00
2 20.0000 31.0 66.00
3 25.0000 27.0 64.00

DEVICE SA005, P005, IS A PIPE


FLOW CODE IS BEGGS-BRILL (MOODY)
INSIDE DIAMETER.............. 40.0000 MM
LENGTH....................... 25.3 M
ELEVATION CHANGE............. 4.0 M
FLOW EFFICIENCY.............. 100.00 PERCENT
HEAT LOSS COEFFICIENT........ 4.88243 KCAL/HR-M2-C
ROUGHNESS.................... 0.04572 MM
AMBIENT TEMPERATURE.......... 26.67 DEG C

LINK L002 (CONT)

DEVICE WA006, B002, IS A BEND


FLOW CODE IS CHISHOLM
THIS IS A STANDARD BEND
PIPE INSIDE DIAMETER......... 40.00 MM
LAMDA (CHISHOLM PARAMETER)... 1.00000
C2 (CHISHOLM PARAMETER)...... 4.35000
RESISTANCE COEFF: MULTPLIER.. 16.0000
ROUGHNESS.................... 0.04570 MM
NUMBER OF DEVICES............ 1.

DEVICE SA007, P007, IS A PIPE


FLOW CODE IS BEGGS-BRILL (MOODY)
INSIDE DIAMETER.............. 40.0000 MM
LENGTH....................... 2.0 M
ELEVATION CHANGE............. 2.0 M
FLOW EFFICIENCY.............. 100.00 PERCENT
HEAT LOSS COEFFICIENT........ 4.88243 KCAL/HR-M2-C
ROUGHNESS.................... 0.04572 MM
AMBIENT TEMPERATURE.......... 26.67 DEG C
DEVICE WA008, B003, IS A BEND
FLOW CODE IS CHISHOLM
THIS IS A STANDARD BEND
PIPE INSIDE DIAMETER......... 40.00 MM
LAMDA (CHISHOLM PARAMETER)... 1.00000
C2 (CHISHOLM PARAMETER)...... 4.35000
RESISTANCE COEFF: MULTPLIER.. 30.0000
ROUGHNESS.................... 0.04570 MM
NUMBER OF DEVICES............ 1.

JUNCTIONS AND SINKS

SINK D001
(D001)
RATE (MASS) ............. 20829.9843 KG/HR
ESTIMATED PRESSURE........ 3.2000 BAR

NODE CONNECTIONS

---- CONNECTIONS ----


NODE NODE NAME NODE TYPE TO NODE VIA LINK
---- --------- --------- --------- ---------
S001 S001 SOURCE D001 L002
D001 D001 SINK S001 L002

LINK CONNECTIONS

LINK LINK NAME FROM NODE TO NODE


---- --------- --------- ----------
L002 L002 S001 D001

+--------------------+
| |
| +----+ +----+ |
| |S001|----|D001| |
| |SRCE| |SINK| |
| +----+ +----+ |
| |
+--------------------+
END OF INPUT PROCESSING -- NO ERRORS
-- 1 WARNING

==============================================================================

VLE K-VALUE DATA FOR SET 'SET01'

SRK PURE COMPONENT DATA

COMP CRITICAL CRITICAL ALPHA C1 C2 C3


TEMPERATURE PRESSURE TYPE
DEG C BAR
---- ---------- ---------- ----- ---------- ---------- ----------
1 374.20 221.19 2 1.0000 0.6620 0.8000

SRK INTERACTION PARAMETERS

KIJ = A(I,J) + B(I,J)/T + C(I,J)/T**2

ALL PAIRS HAVE BEEN DEFAULTED TO IDEAL


==============================================================================

THERMODYNAMIC SETS USED FOR EACH UNIT OPERATION

DEFAULT METHOD IS SET01

THERMODYNAMIC SET UNIT OPERATIONS


----------------- ---------------
SET01
==============================================================================

THERMODYNAMIC METHODS USED FOR EACH SET

THERMODYNAMIC SET SET01 (DEFAULT)

PROPERTY METHOD
-------- ------
KVALUE(VLE) SOAVE-REDLICH-KWONG
KVALUE(LLE) UNSPECIFIED
KVALUE(SLE) UNSPECIFIED
LIQUID ENTHALPY SOAVE-REDLICH-KWONG
VAPOR ENTHALPY SOAVE-REDLICH-KWONG
LIQUID DENSITY API
VAPOR DENSITY SOAVE-REDLICH-KWONG
LIQUID ENTROPY SOAVE-REDLICH-KWONG
VAPOR ENTROPY SOAVE-REDLICH-KWONG
LIQUID VISCOSITY PETROLEUM
VAPOR VISCOSITY PETROLEUM
LIQUID CONDUCTIVITY PETROLEUM
VAPOR CONDUCTIVITY PETROLEUM
SURFACE TENSION PETROLEUM
LIQUID DIFFUSIVITY UNSPECIFIED
==============================================================================

COMPONENT COMP. TYPE PHASE MOL. WEIGHT DENSITY


KG/M3
--------------------- ----------- ----------- ----------- -----------
1 H2O LIBRARY VAP/LIQ 18.015 998.566

COMPONENT NBP CRIT. TEMP. CRIT. PRES. CRIT. VOLM.


C C BAR M3/KG-MOL
--------------------- ----------- ----------- ----------- -----------
1 H2O 100.000 374.200 221.192 0.0554

COMPONENT ACEN. FACT. HEAT FORM. G FORM.


KCAL/KG-MOL KCAL/KG-MOL
--------------------- ----------- ----------- -----------
1 H2O 0.34800 -57799.99 -54646.99
Index

Solution History

R
PIPEPHASE Version 9.1 - INPUT MODULE
==========================================

*** SCANNING
GENERAL DATA
COMPONENT DATA
METHODS DATA
THERMODYNAMIC DATA
PROPERTY DATA
STRUCTURE DATA

END OF PRE-PROCESSING -- NO ERRORS


R
PIPEPHASE Version 9.1 - CROSS CHECKING MODULE
===================================================

*** CHECKING
GENERAL DATA
STRUCTURE DATA
CASE STUDY DATA
PVTG DATA
METHODS DATA

*** INPUT REPRINT


GENERAL DATA
METHODS DATA
STRUCTURE DATA
NETWORK DATA

*** FORMATTING DATA

END OF INPUT PROCESSING -- NO ERRORS


-- 1 WARNING

END OF INPUT CROSS-CHECKING -- NO ERRORS.


R
PIPEPHASE Version 9.1 - CALCULATION MODULE
================================================
ITERATION NUMBER 0. 0

END OF NETWORK PROCESSING -- NO ERRORS


-- 8 WARNINGS

*** BASE CASE SOLVED ***

*** NETWORK SIMULATION SOLVED

CALCULATION STARTED 17:20:18 11/16/17


CALCULATION FINISHED 17:20:18 11/16/17
CALCULATION RUN TIME 0 HR 0 MIN 0 SEC

NETWORK SIMULATION SOLVED


Index

Node Summary - Base Case

Gas Weight Oil Weight Water Weight Total Weight Water LV Rate Gas Specific
Node Pressure Temperature Gas GV Rate Oil LV Rate
Rate Rate Rate Rate Gravity

BAR DEG C KG/HR KG/HR KG/HR KG/HR MM M3/HR M3/HR M3/HR

S001 1.11 25.00 .000 0.00 20,829.89 20,829.89 0.00 0.00 20.86 0.00
D001 1.72 25.08 .000 0.00 -20,829.89 -20,829.89 0.00 0.00 -20.86 0.00
Rates reported at standard conditions. Specified values are underlined.
Oil Specific Water Specific
Gravity Gravity

0.00 1.00
0.00 1.00
Index

Link Summary - Base Case

Inlet / Pressure
Link Name Node Name Gas GV Rate Oil LV Rate Water LV Rate Pressure Temperature Gas Holdup Liquid Holdup
Outlet Change
MM M3/HR M3/HR M3/HR BAR BAR DEG C MM SCM ACM

L002 In S001 0.0000 0.00 20.90 1.11 25.00


Out D001 0.0000 0.00 20.90 1.72 -0.61 25.08 0.0000 0.04
Rates reported at actual conditions. Gas holdup reported at standard conditions. Specified pressures are underlined.
Index

Device Summary - Base Case

Inside Measured Elevation Outlet Outlet Outlet In-Situ Outlet Liquid Total Mass
Link Name Device Name Device Type Diameter Length Change Pressure Temperature Quality Holdup Rate

MM M M BAR DEG C KG/HR

L002 P002 PIPE 50.00 2.00 2.00 0.88 25.00 0.00 1.00 20,830
L002 B001 BEND 50.00 0.00 0.00 0.85 25.00 20,830
L002 P003 PIPE 50.00 1.00 0.00 0.83 25.00 0.00 1.00 20,830
L002 P004 PUMP 0.00 0.00 0.00 3.97 25.04 20,830
L002 P005 PIPE 40.00 25.31 4.00 2.14 25.08 0.00 1.00 20,830
L002 B002 BEND 40.00 0.00 0.00 2.10 25.08 20,830
L002 P007 PIPE 40.00 2.00 2.00 1.79 25.08 0.00 1.00 20,830
L002 B003 BEND 40.00 0.00 0.00 1.72 25.08 20,830
Index

Structure Summary - Base Case

Inlet Inside Outlet Inside Measured Elevation


Link Name Device Name Device Type Diameter Diameter Length Change

MM MM M M

L002 P002 PIPE 50.00 50.00 2.0 2.0


L002 B001 BEND 50.00 0.0 0.0
L002 P003 PIPE 50.00 50.00 1.0 0.0
L002 P004 PUMP 0.0 0.0
L002 P005 PIPE 40.00 40.00 25.3 4.0
L002 B002 BEND 40.00 0.0 0.0
L002 P007 PIPE 40.00 40.00 2.0 2.0
L002 B003 BEND 40.00 0.0 0.0
Index

Velocity Summary - Base Case

Outlet Outlet
Inlet Mixture Critical Inlet Pressure Pressure
Link Name Device Name Device Type Mixture Pressure
Velocity Velocity Gradient Change
Velocity Gradient
M/SEC M/SEC M/SEC BAR/M BAR/M BAR

L002 P002 PIPE 2.96 2.96 0.00 -0.1159 -0.1159 -0.23


L002 B001 BEND -0.03
L002 P003 PIPE 2.96 2.96 0.00 -0.0182 -0.0182 -0.02
L002 P004 PUMP 3.14
L002 P005 PIPE 4.62 4.62 0.00 -0.0726 -0.0726 -1.84
L002 B002 BEND -0.04
L002 P007 PIPE 4.62 4.62 0.00 -0.1548 -0.1548 -0.31
L002 B003 BEND -0.07
Index

Results Summary - Base Case

Seg 1 Mixture Inlet Pressure Outlet Inlet Outlet


Link Name Device Name Device Type Inlet Quality Outlet Quality
Flow Rate Pressure Temperature Temperature

KG/HR BAR BAR DEG C DEG C Fraction Fraction

L002 P002 PIPE 20,829.89 1.11 0.88 25.00 25.00 0.0000 0.0000
L002 B001 BEND 20,829.89 0.88 0.85 25.00 25.00
L002 P003 PIPE 20,829.89 0.85 0.83 25.00 25.00 0.0000 0.0000
L002 P004 PUMP 20,829.89 0.83 3.97 25.00 25.04
L002 P005 PIPE 20,829.89 3.97 2.14 25.04 25.08 0.0000 0.0000
L002 B002 BEND 20,829.89 2.14 2.10 25.08 25.08
L002 P007 PIPE 20,829.89 2.10 1.79 25.08 25.08 0.0000 0.0000
L002 B003 BEND 20,829.89 1.79 1.72 25.08 25.08
Index

Flash Report for Node S001 - Base Case

Vapor Liquid1 Vap+Liq1 Liquid2 Total


Temp DEG C 25.00
Pressure BAR 1.11

COMPONENT Mole Fraction


H2O 0.000000 0.000000 0.000000 1.000000 1.000000

TOTAL RATES
Weight Rate KG/HR 0.00 0.00 0.00 20,829.89 20,829.89
Molar Rate KG-M/HR 0.00 0.00 0.00 1,156.25 1,156.25

PHASE PROPERTIES
Mass Fraction 0.000000 0.000000 0.000000 1.000000 1.000000
Volume Fraction 0.000000 0.000000 0.000000 1.000000 1.000000
Density KG/M3 0.00 0.00 996.80
Actual SPGR 0.0000 0.0000 0.9978
Viscosity CP 0.0000 0.0000 0.8901
Enthalpy KCAL/KG 0.000 0.000 25.074 25.074
Surface Tension NEWTON/M 0.000 0.072
Molecular Wt 0.000 0.000 0.000 18.015 18.015
Flash Report for Node D001 - Base Case

Vapor Liquid1 Vap+Liq1 Liquid2 Total


Temp DEG C 25.08
Pressure BAR 1.72

COMPONENT Mole Fraction


H2O 0.000000 0.000000 0.000000 1.000000 1.000000

TOTAL RATES
Weight Rate KG/HR 0.00 0.00 0.00 20,829.89 20,829.89
Molar Rate KG-M/HR 0.00 0.00 0.00 1,156.25 1,156.25

PHASE PROPERTIES
Mass Fraction 0.000000 0.000000 0.000000 1.000000 1.000000
Volume Fraction 0.000000 0.000000 0.000000 1.000000 1.000000
Density KG/M3 0.00 0.00 996.78
Actual SPGR 0.0000 0.0000 0.9978
Viscosity CP 0.0000 0.0000 0.8885
Enthalpy KCAL/KG 0.000 0.000 25.167 25.167
Surface Tension NEWTON/M 0.000 0.072
Molecular Wt 0.000 0.000 0.000 18.015 18.015
Index

Pump Summary - Base Case

Actual Inlet Suction Outlet Outlet


Name Head Efficiency
Rate Pressure Pressure Temperature
M3/HR BAR BAR DEG C M HEAD

P004 20.90 0.83 3.97 25.04 30.28 0.66


Power Stage

KW

2.62 1.00
Index

L002 - Base Case

Temperature Pressure Report - Base Case

Device Device MWD Or TVD Or Total Inside Ambient


Name Pressure Temperature Temperature U Factor Quality
Type Seg Total Length Elevation Diameter

M M MM BAR DEG C DEG C KCAL/HR-M-C

P002 PIPE Inlet 0.00 0.00 50.00 1.11 25.00 26.67 0.00 0.00
P002 PIPE Seg 1 1.00 1.00 50.00 0.99 25.00 26.67 4.88 0.00
P002 PIPE Outlet 2.00 2.00 50.00 0.88 25.00 26.67 4.88 0.00
B001 BEND Inlet 2.00 2.00 50.00 0.88 25.00 26.67
B001 BEND Outlet 2.00 2.00 50.00 0.85 25.00 26.67
P003 PIPE Inlet 2.00 2.00 50.00 0.85 25.00 26.67 0.00 0.00
P003 PIPE Seg 1 2.50 2.00 50.00 0.84 25.00 26.67 4.88 0.00
P003 PIPE Outlet 3.00 2.00 50.00 0.83 25.00 26.67 4.88 0.00
P004 PUMP Inlet 3.00 2.00 0.00 0.83 25.00 26.67
P004 PUMP Outlet 3.00 2.00 0.00 3.97 25.04 26.67
P005 PIPE Inlet 3.00 2.00 40.00 3.97 25.04 26.67 0.00 0.00
P005 PIPE Seg 1 15.66 4.00 40.00 3.05 25.06 26.67 4.88 0.00
P005 PIPE Outlet 28.31 6.00 40.00 2.14 25.08 26.67 4.88 0.00
B002 BEND Inlet 28.31 6.00 40.00 2.14 25.08 26.67
B002 BEND Outlet 28.31 6.00 40.00 2.10 25.08 26.67
P007 PIPE Inlet 28.31 6.00 40.00 2.10 25.08 26.67 0.00 0.00
P007 PIPE Seg 1 29.31 7.00 40.00 1.94 25.08 26.67 4.88 0.00
P007 PIPE Outlet 30.31 8.00 40.00 1.79 25.08 26.67 4.88 0.00
B003 BEND Inlet 30.31 8.00 40.00 1.79 25.08 26.67
B003 BEND Outlet 30.31 8.00 40.00 1.72 25.08 26.67
Surface Pressure Plot for Link L002 - Base Case Surface Temperature Plot for Link L002 - Base Case
5 27

4
27
4

3 26

Temperature, DEG C
3
Pressure, BAR

26
2

2 25

1
25
1

0 24
0 5 10 15 20 25 30 35 0 5 10 15 20 25 30 35

Distance from Inlet, M Distance from Inlet, M

Fluid Fluid Ambient


Equipment Report - Base Case

Device Device MWD Or TVD Or Total


Name Pressure Temperature Property Units Value
Type Seg Total Length Elevation
M M BAR DEG C

P002 PIPE Inlet 0.00 0.00 1.11 25.00


P002 PIPE Outlet 2.00 2.00 0.88 25.00
B001 BEND Inlet 2.00 2.00 0.88 25.00
B001 BEND Outlet 2.00 2.00 0.85 25.00
P003 PIPE Inlet 2.00 2.00 0.85 25.00
P003 PIPE Outlet 3.00 2.00 0.83 25.00
P004 PUMP Inlet 3.00 2.00 0.83 25.00
Avail. Power KW 0.00
Req. Power KW 2.62
Speed RPM
Efficiency 0.66
P004 PUMP Outlet 3.00 2.00 3.97 25.04
P005 PIPE Inlet 3.00 2.00 3.97 25.04
P005 PIPE Outlet 28.31 6.00 2.14 25.08
B002 BEND Inlet 28.31 6.00 2.14 25.08
B002 BEND Outlet 28.31 6.00 2.10 25.08
P007 PIPE Inlet 28.31 6.00 2.10 25.08
P007 PIPE Outlet 30.31 8.00 1.79 25.08
B003 BEND Inlet 30.31 8.00 1.79 25.08
B003 BEND Outlet 30.31 8.00 1.72 25.08
Holdup and Velocity Report - Base Case

Liquid Gas
Device Device No Slip Liquid Slip Liquid Total Liquid Mixture Sonic Velocity Flow Regime
Name Superficial Superficial
Type Seg Holdup Holdup Holdup Velocity Corr / T-D
Velocity Velocity
ACM M/SEC M/SEC M/SEC M/SEC

P002 PIPE Inlet 0.000 0.000 0.000 0.000 0.000 ---- ----
P002 PIPE Seg 1 1.000 1.000 0.002 2.956 0.000 2.956 0.000 1-PH 1-PH
P002 PIPE Outlet 1.000 1.000 0.004 2.956 0.000 2.956 0.000 1-PH 1-PH
B001 BEND Inlet 0.004 0.062 0.000 ---- ----
B001 BEND Outlet 0.004 0.062 0.000 DIST 1-PH
P003 PIPE Inlet 0.004 0.062 0.000 DIST 1-PH
P003 PIPE Seg 1 1.000 1.000 0.005 2.956 0.000 2.956 0.000 1-PH 1-PH
P003 PIPE Outlet 1.000 1.000 0.006 2.956 0.000 2.956 0.000 1-PH 1-PH
P004 PUMP Inlet 0.006 0.062 0.000 ---- ----
P004 PUMP Outlet 0.006 0.062 0.000 ---- ----
P005 PIPE Inlet 0.006 0.062 0.000 ---- ----
P005 PIPE Seg 1 1.000 1.000 0.022 4.619 0.000 4.619 0.000 1-PH 1-PH
P005 PIPE Outlet 1.000 1.000 0.038 4.619 0.000 4.619 0.000 1-PH 1-PH
B002 BEND Inlet 0.038 0.062 0.000 ---- ----
B002 BEND Outlet 0.038 0.062 0.000 DIST 1-PH
P007 PIPE Inlet 0.038 0.062 0.000 DIST 1-PH
P007 PIPE Seg 1 1.000 1.000 0.039 4.619 0.000 4.619 0.000 1-PH 1-PH
P007 PIPE Outlet 1.000 1.000 0.040 4.619 0.000 4.619 0.000 1-PH 1-PH
B003 BEND Inlet 0.040 0.062 0.000 ---- ----
B003 BEND Outlet 0.040 0.062 0.000 DIST 1-PH
Pressure Gradient Report - L002 Base Case

Friction Elevation Friction Elevation


Device Device Total Pressure
Name Pressure Pressure Pressure Pressure
Type Seg Gradient
Gradient Gradient Change Change
BAR/M BAR/M BAR/M BAR BAR

P002 PIPE Inlet


P002 PIPE Seg 1 -0.018 -0.098 -0.116 -0.018 -0.098
P002 PIPE Outlet -0.018 -0.098 -0.116 -0.018 -0.098
B001 BEND Inlet
B001 BEND Outlet
P003 PIPE Inlet
P003 PIPE Seg 1 -0.018 0.000 -0.018 -0.009 0.000
P003 PIPE Outlet -0.018 0.000 -0.018 -0.009 0.000
P004 PUMP Inlet
P004 PUMP Outlet
P005 PIPE Inlet
P005 PIPE Seg 1 -0.057 -0.015 -0.073 -0.723 -0.195
P005 PIPE Outlet -0.057 -0.015 -0.073 -0.723 -0.195
B002 BEND Inlet
B002 BEND Outlet
P007 PIPE Inlet
P007 PIPE Seg 1 -0.057 -0.098 -0.155 -0.057 -0.098
P007 PIPE Outlet -0.057 -0.098 -0.155 -0.057 -0.098
B003 BEND Inlet
B003 BEND Outlet
Viscosity Density Report - Base Case

Device Device Liquid Vapor Liquid No Slip


Name Oil Viscosity Vapor Density Slip Density
Type Seg Viscosity Viscosity Density Density
CP CP CP KG/M3 KG/M3 KG/M3 KG/M3

P002 PIPE Inlet


P002 PIPE Seg 1 0.000 0.890 0.000 996.797 0.000 996.797 996.797
P002 PIPE Outlet 0.000 0.890 0.000 996.798 0.000 996.798 996.798
B001 BEND Inlet 0.000 0.890 0.000 996.797 0.000
B001 BEND Outlet 0.000 0.890 0.000 996.797 0.000
P003 PIPE Inlet 0.000 0.890 0.000 996.797 0.000
P003 PIPE Seg 1 0.000 0.890 0.000 996.797 0.000 996.797 996.797
P003 PIPE Outlet 0.000 0.890 0.000 996.797 0.000 996.797 996.797
P004 PUMP Inlet 0.000 0.890 0.000 996.797 0.000
P004 PUMP Outlet 0.000 0.890 0.000 996.797 0.000
P005 PIPE Inlet 0.000 0.890 0.000 996.797 0.000
P005 PIPE Seg 1 0.000 0.889 0.000 996.784 0.000 996.784 996.784
P005 PIPE Outlet 0.000 0.889 0.000 996.781 0.000 996.781 996.781
B002 BEND Inlet 0.000 0.889 0.000 996.778 0.000
B002 BEND Outlet 0.000 0.889 0.000 996.778 0.000
P007 PIPE Inlet 0.000 0.889 0.000 996.778 0.000
P007 PIPE Seg 1 0.000 0.889 0.000 996.778 0.000 996.778 996.778
P007 PIPE Outlet 0.000 0.889 0.000 996.778 0.000 996.778 996.778
B003 BEND Inlet 0.000 0.889 0.000 996.778 0.000
B003 BEND Outlet 0.000 0.889 0.000 996.778 0.000
Friction Report - Base Case

Liquid
Device Device Friction Friction Friction Friction Friction Reynolds
Name Surface
Type Seg Density Velocity Diameter Viscosity Factor Number Tension
KG/M3 M/SEC MM CP NEWTON/M

P002 PIPE Inlet 0.000


P002 PIPE Seg 1 996.797 2.956 50.000 0.890 0.021 1.655E+05 0.072
P002 PIPE Outlet 996.798 2.956 50.000 0.890 0.021 1.655E+05 0.072
B001 BEND Inlet 0.072
B001 BEND Outlet 0.072
P003 PIPE Inlet 0.000 0.072
P003 PIPE Seg 1 996.797 2.956 50.000 0.890 0.021 1.655E+05 0.072
P003 PIPE Outlet 996.797 2.956 50.000 0.890 0.021 1.655E+05 0.072
P004 PUMP Inlet 0.000 0.000 0.072
P004 PUMP Outlet 0.000 0.000 0.072
P005 PIPE Inlet 1,591.470 0.000 0.072
P005 PIPE Seg 1 996.784 4.619 40.000 0.889 0.022 2.071E+05 0.072
P005 PIPE Outlet 996.781 4.619 40.000 0.889 0.022 2.072E+05 0.072
B002 BEND Inlet 0.072
B002 BEND Outlet 0.072
P007 PIPE Inlet 0.000 0.072
P007 PIPE Seg 1 996.778 4.619 40.000 0.889 0.022 2.073E+05 0.072
P007 PIPE Outlet 996.778 4.619 40.000 0.889 0.022 2.073E+05 0.072
B003 BEND Inlet 0.072
B003 BEND Outlet 0.072
Heat Transfer Report - Base Case

Device Fluid Thermal Inside Film Insulation Surrounding


Device Pipe Thermal Liquid Vapor Hydrate
Name Thermal Thermal Thermal
Type Seg Conduct. Resistance Enthalpy Enthalpy Formation
Resistance Resistance Resistance
HR-M2- HR-M2- HR-M2- HR-M2-
KCAL/HR-M-C C/KCAL C/KCAL C/KCAL C/KCAL KCAL/KG KCAL/KG

P002 PIPE Inlet 0.0000 0.0000 0.0000 0.0000 25.074 0.000


P002 PIPE Seg 1 0.0000 0.0000 0.0000 0.0000 25.072 0.000
P002 PIPE Outlet 0.0000 0.0000 0.0000 0.0000 25.072 0.000
B001 BEND Inlet 25.072 0.000
B001 BEND Outlet 25.072 0.000
P003 PIPE Inlet 0.0000 0.0000 0.0000 0.0000 25.072 0.000
P003 PIPE Seg 1 0.0000 0.0000 0.0000 0.0000 25.072 0.000
P003 PIPE Outlet 0.0000 0.0000 0.0000 0.0000 25.072 0.000
P004 PUMP Inlet 25.072 0.000
P004 PUMP Outlet 25.072 0.000
P005 PIPE Inlet 0.0000 0.0000 0.0000 0.0000 25.180 0.000
P005 PIPE Seg 1 0.0000 0.0000 0.0000 0.0000 25.176 0.000
P005 PIPE Outlet 0.0000 0.0000 0.0000 0.0000 25.172 0.000
B002 BEND Inlet 25.172 0.000
B002 BEND Outlet 25.172 0.000
P007 PIPE Inlet 0.0000 0.0000 0.0000 0.0000 25.172 0.000
P007 PIPE Seg 1 0.0000 0.0000 0.0000 0.0000 25.170 0.000
P007 PIPE Outlet 0.0000 0.0000 0.0000 0.0000 25.168 0.000
B003 BEND Inlet 25.168 0.000
B003 BEND Outlet 25.168 0.000
Device