The present work describes the performance of a packed tower with Raschig rings ,
which is fed with an airflow which is increased gradually countercurrent with a constant
liquid flow, for each interval the pressure difference is measured in the tower. The
experience is initially made with no water flow and then is repeated at very high and low
flows up to the point of flooding. The results indicate that the correlation developed by
Leva doesnt give a good representation of the operation data of the packed tower; this is
because it was developed for a tower of gas-liquid contact. By Reynold's number is
verified that the airflow was not in turbulent. The higher range of pressure drop belongs to
the 25% flow and the lower range belongs to the 80% flow.
Key words: packed tower, airflow, water flow, high flow, low flow, Leva.
Resumen
El presente trabajo describe el comportamiento de una torre empacada con anillos Raschig
de , la cual se alimenta con un flujo de aire que se va aumentando poco a poco en
contracorriente con un flujo de lquido constante, para cada intervalo se mide la diferencia
de presin en la torre. La experiencia es realizada inicialmente sin paso de agua y luego es
repetida a caudales altos y bajos hasta el punto de inundacin. Los resultados indicaron que
la correlacin desarrollada por Leva no da una buena representacin de los datos de
operacin de la torre empacada del laboratorio, ya que Leva fue desarrollada para una torre
de contacto gas-lquido. Mediante el nmero de Reynold se verific que el flujo de aire no
se encontraba en rgimen turbulento. El rango mayor de cada de presin lo posee el flujo
menor de 25% y el rango menor lo posee el de 80%
Palabras claves: torre empacada, flujo de aire, flujo de agua, flujo alto, flujo bajo, Leva.
Introduccin rotmetros marca Fisher para medir el
flujo de aire y agua, tambin cuenta con
1.1.- Se verific que la vlvula de drenaje 2.1.- Se cheque que el manmetro PG-
de la torre este completamente 501 tenga 110 psig de presin y se
cerrada. abri con mucho cuidado la vlvula
HV-501 de admisin de aire al
1.2.- Se verific que las vlvulas HV-
rotmetro FG-502.
507, HV-506, HV-505 de admisin
de agua de hidrolago a la torre estn 2.2.- Se Aument el flujo de aire a travs
completamente cerradas. del rotmetro FG-502, en intervalos
de 5% comenzando desde 10% hasta
1.3.- Se verific que las vlvulas HV-503,
60%, con un flujo de lquido igual
HV-502, de admisin de aire del
cero.
pulmn hacia el laboratorio estn
abiertas. 2.3.- Por cada flujo de aire establecido, se
midi la cada de presin de la torre a
1.4.- Se verific que la vlvula HV-504
travs del manmetro diferencial
de salida del pulmn de aire
PDG-501. Los resultados se
estuviera abierta.
muestran a continuacin en la
Tabla#1
3.5.- Se aument el flujo de aire a travs
del rotmetro FG-502, en intervalos
de 2% comenzando desde 10% hasta
observar la inundacin.
2
tericas). Esta cada de presin es un factor
1 importante en el diseo de columnas
y = 0,5304x3 + 3,3047x2 + 7,4507x + 4,2239
R = 0,9957
empacadas. Cada tipo de material de empaque
Log (P/Z)
0 log
(P/Z) tiene un volumen vaco fijo para el paso del
teo
-1 lquido, el factor de empaque tambin vara
log segn la colocacin de los mismos, es decir,
(P/Z)
-2
exp no es lo mismo colocar un empaque seco, que
y = 2,0278x + 0,4686
R = 0,9949
-3 cuando la columna esta llena de lquido;
-1,8 -1,6 -1,4 -1,2 -1 -0,8 -0,6
Log (Ut) generalmente los tamaos mas pequeos de
empaques al azar ofrecen superficies
Fig N1: Perdidas de energa para distintos caudales de gas
especficas mayores y por lo tanto mayores
y caudal de lquido igual a cero.
cadas de presin. Realmente lo que sucede en
este caso es que a lo mejor los empaques no
Se puede notar claramente que la
estaban completamente secos, por lo que no
prediccin de la ecuacin de Leva para Empaque
hubo una completa transferencia de gas a
seco es muy pobre o diferente a la obtenida
travs de los empaques ya que si estaban
experimentalmente, ya que la curva terica se
mojados ocurrira una pequea absorcin entre
encuentra muy por debajo de la experimental.
el poco lquido y el flujo de gas.
Se observa que a medida que la
velocidad del gas aumenta, de igual manera
aumenta la cada de presin en la torre,
adicionalmente, se visualiza poco ajuste de los
datos de cadas de presin experimentales en
comparacin con los calculados por la
ecuacin de Leva (o cadas de presin
La representacin grfica de los resultados
experimentales exhibe un comportamiento
particular, primero muestra un comportamiento
lineal, y luego, a medida que se incrementa la
velocidad superficial del aire, la recta empieza a
torcerse hacia arriba, tal que para una velocidad
ms alta la cada de presin aumenta rpidamente
para un pequeo incremento de la velocidad del
aire. Justo donde se encuentra el punto de
inflexin de la curva se define el punto de carga y
al final de la curva, conforme aumenta la
velocidad del aire, se define el punto de
De la tabla N4 de manera general, inundacin la inversin de las fases, siendo el aire
puede decirse que el porcentaje de error oscila la fase discontinua y el agua la fase continua. En
este punto el agua queda retenida en el tope de la
entre 89% y 92% sin embargo no presenta un
torre, creando un tapn de lquido observndose
comportamiento regular de aumento o burbujeo de aire a travs del agua. En
disminucin a medida que aumenta el flujo de comparacin con la correlacin de Leva, se
observan grandes desviaciones respecto a las
gas.
prdidas de energa experimentales. Se destacan
dos variables importantes en el punto de
Para regmenes de flujo de agua bajo se
inundacin el caudal o velocidad de aire y la
obtuvieron los siguientes comportamientos:
cada de presin a la que ocurre la inundacin.
Para un flujo de lquido constante, a medida que
log
(P/Z)
aumenta la velocidad del flujo de aire, aumentan
1
teo las prdidas por friccin, reflejndose en las
25%
prdidas de presin en la torre y por lo tanto se
0 incrementan las prdidas de energa. A medida
log
(P/Z) que transcurre el tiempo los espacios vacos en el
Log (P/Z)
exp
-1 25% empaque empiezan a cubrirse con agua,
provocando un aumento en la cada de presin
log mayor. En este momento se alcanza el punto de
-2 (P/Z)
teo carga, y a partir de este punto el aumento en la
35% cada de presin es grande para pequeos
-3 cambios en la velocidad superficial del gas. Si el
-1,2 -1 -0,8 -0,6 -0,4 -0,2 log (Ut) flujo de gas sigue en aumento, la presin del gas
hacia el lquido es tan grande que el gas ejerce
una fuerza hacia el lquido retenindolo,
Fig N2: Log(P/z) vs. Log(Ut) para Flujo de
formando un tapn de lquido en la torre, en
Agua bajo
donde la fase gaseosa ser la fase discontinua y la
fase lquida la fase continua. En este punto se
produce la inundacin de la torre, y son las
condiciones extremas de operacin en una torre
empacada.
(P/Z)exp
de Leva cuando existe la presencia de 0 65%
lquido, adems cabe destacar que dicha -1 log
ecuacin se desarroll a partir de datos del -2
(P/Z)teo
80%
sistema aire-agua funcionando por debajo
-3 log
del punto de inundacin mientras que en la (P/Z)exp
-4
prctica se elev el caudal de aire hasta -1,4 Log (Ut) -0,9 -0,4
80%
Log (P/Z)
figura N4. Flujo de
Agua
-0,5 65%
Flujo de
-1 Agua
80&
Punto
-1,5 de Carga
-2 Limite
-1,3 -1,1 -0,9 -0,7 -0,5 -0,3 -0,1 de
Operaci
Log (Ut) n
BIBLIOGRAFA
I. Perdidas de energa de la C-501 en funcin del flujo de gas, sin flujo de lquido
= 2 10(3 ) 2 (ec.1)
Donde:
P: Cada de presin en la torre por longitud de empaque (in H2O/Ft)
g : Densidad del gas (Lb/Ft)
Ut: Velocidad superficial del gas (Ft/s)
ut: Velocidad superficial del lquido (Ft/s)
C2 y C3: Constantes del empaque
Z: Altura de la torre empacada (Ft)
Conociendo el tamao nominal (1/2 in) y el espesor de la pared del empaque (3/32 in) se
entra a la Tabla 18.7 del Manual del Ingeniero Qumico. Perry, Tomo V (Anexo) se conoce
los coeficientes para la ecuacin de Leva; mostrados en la siguiente tabla:
2
ft
A= (15,5cm ) = 2,031 101 ft 2
4 30,48 cm
1 m
A = 2,031E 1 ft = 1,887E 2 m
(3,28 ft)
Entonces . =
El flujo molar (n) es constante
Q1 P1 Q0 P0
= (ec.4)
T1 T0
8,1 ft 3
0 = = 3,823 103 m/s
min
m3
Q0 P0 T1 3,823 103 s 760 mmHg (22 C + 273,15)
1 = = = 3,835E 3 m/s
T0 P1 (21,11 C + 273,15) 760 mmHg
Qaire
Ut
A
Donde:
A D2 0,155m 0,0189m 2
2
4 4
3 %
10 = 3,835 3
100
3 10 3
10 = 3,835 3 = 3.835 4
100
3,835 4/
= = 2,04 2 /
1,889 2
(/) = 2,04 2 3,28084 = , /
1
La densidad del aire puede calcularse a partir de la ecuacin de gas ideal: PV = nRT
w w PM
PV RT
M V RT
Para el aire:
M = 29lb/lbmol
lb
1atm 14,7 f in2 144in 2
P 758mmHg 2
2110,65 lb f ft 2
760mmHg 1atm 1 ft
R = 1545ftlbf/Rlbmol
T = 23C = 533,07R
2110,65 lb f
ft 2
29
lb
lbmol
Aire
1545 533,07 R 0,0743
lb
ft .lb f ft 3
R.lbmol
log = log(2 ) + log() + 2 log()
Sustituyendo:
log = log(3,5) + log(7,431 2) + 2 log(6,707 2)
log = 2,9318
= , /
De la misma manera se obtienen las cadas de presin tericas por longitud de empaque para
los dems caudales de aire.
1 2
0,4 2
2,54 2
= = , /
1
149 30,48
log = 1,4919
De la misma manera se obtienen las cadas de presin experimentales por longitud de empaque
para los dems caudales de aire.
II. Perdidas de energa de la C-501 en funcin del flujo de gas, a dos regmenes de
flujo de liquido bajo y flujo de lquido alto.
. Clculo de las prdidas de energa tericas y experimentales para distintos caudales de gas a
un caudal de lquido bajo.
100% rotmetro de agua equivale a 2,7gpm para un lquido con gravedad especifica de 1
Qagua
ut
A
1,504 3 /
= = 7,406 3 /
2,031 1 2
Para 10% de Rotmetro de aire
= 3,857 4 /
= 6,707 2 /
Cada de Presin por longitud de empaque Terica
log = log(3,5) + (0,0577 log 10) + log(7,431 2) + 2 log()
Sustituyendo las velocidades lineales del aire y del agua; en este caso para 10% de Rotmetro
de Aire y 25% de Rotmetro de Agua queda:
log = log(3,5) + (0,0577 7,406 3 /) + log(7,431 2)
+ 2 log(6,707 2 /)
log = 2.9314
= 1.17 3 inH2O ft
De igual manera se calculan las cadas de presin tericas por longitud de empaque para los
diferentes caudales de gas.
1 2
1 2
2,54 2
= = . /
1
149 30,48
log = 1,0942
De igual manera se calculan las cadas de presin experimentales por longitud de empaque para
los diferentes caudales de aire.
Se realiza de la misma manera para los dems porcentajes de rotmetro de agua 35%
Clculo de las prdidas de energas tericas y experimentales para distintos caudales de gas a
un caudal de lquido alto
3.91 3 /
= = 1.926 2 /
2,031 1 2
= 6,707 2 /
Cada de Presin por longitud de empaque Terica
log = log(3,5) + (0,0577 1.926 2 /) + log(7,431 2)
+ 2 log(6,707 2 /)
log = 2.9307
= 1.173 3 inH2O ft
De igual manera se calculan las cadas de presin tericas por longitud de empaque para los
diferentes caudales de gas.
1 2
0.3 2
2,54 2
= = . /
1
149
30,48
log = 1,6170
De igual manera se calculan las cadas de presin experimentales por longitud de empaque para
los diferentes caudales de aire.
Se realiza de la misma manera para los dems porcentajes de rotmetro de agua 80%
Cada de Presin en el punto de inundacin
Se realiza este mismo procedimiento para los dems porcentajes de rotmetro de agua
0,1
= :
( )
@ 23C y 758mmHg
= 997,255 / = 940,2375 6
= 9,4 4 /( )
= 1,190 /
= (%)
La velocidad lineal del agua obtenida se debe llevar a unidades del sistema internacional (m/s)
( ) = 7,406 3 = 2,26 3 /
= 2,26 3 997,255 3
= , /( )
m
Se utiliza el Ut de inundacin experimental Ut= 1,554E 01 (ver tabla #)
s
= (ec.13)
m
= 1,554E 01 1,190 3
s
= , /( )
Para entrar en la grfica de Eckert se debe calcular X y Y
2,2510 1,190
=
1,85 1 997,255 1,190
= ,
0,1
=
( )
= ,
Asumiendo = 0,90m/s
m
= 0,90 1,190 3 = 1,071
s
2,2510 1,190
= = 0,0726
1,071 997,255 1,190
(1,071)580(9,44)0,1
= =0.2796
1,190(997,2551,190)
3
, = , = 0,90 1,887 2 = 0,0168
3
, = , = 0,0168 997,255 3 = 0,02
De igual forma se procede para el clculo de los restantes QA inund,teo para los diferentes flujos
de agua.
, = , , = 1,554E 01 m 1,887 2
3
, = 2,92 3
Se calcula el % de error para cada uno de los % de rotmetro de agua
0,0168 / 2,92 3 /
%25% = | | 100%
2,92 3 /
%25% = 474,194%
Anlogamente se determinan los dems porcentajes de error para los distintos flujos de agua
0,71379378(0,91791376)
= |0,75849873( 0,79326083)| =5,87191067
Se comparan las ecuaciones empricas obtenidas en cada una de las curvas de porcentaje
de rotmetro de agua tanto flujo bajo, como flujo alto y tambin para los empaques secos hasta
el punto de carga.
% 3 2
( ) = (()) + (()) + () +
Donde:
Se realiza un clculo del nmero de Reynolds para verificar si uno de los fluidos de trabajo
(aire) se encuentra en una condicin turbulenta, adaptndose a la ecuacin de leva.
4
=
Donde:
Q: Caudal (m/s)
: Viscosidad=0,018 = 1,8 5
(/) ,% (/),%
%(/)% = | | 100%
(/),%
2 0,08052
1,171 3
%(/)25% =| | 100% = 98,55%
2
0,0805
Se realiza este clculo para los distintos porcentajes de rotmetro de aire y agua.
ANEXOS
Coeficiente de inundacin Cf
Coeficientes para la ecuacin de Leva
Coordenadas de Eckert