Sunteți pe pagina 1din 25

C-02 Gauge Valves and Instrumentation Manifolds

Gauge Valves and


Instrumentation Manifolds
GV, GVH, GR Series
2-valve, 3-valve and 5-valve Manifold Series
Manifolds
Gauge Valves and Instrumentation Manifolds C-03

Contents

Gauge Valves
GV Series, GVH Series and GR Series

C-04

Instrumentation Manifolds
2-valve Manifolds

C-09

3-valve Manifolds

C-13
5-valve Manifolds

C-15

C Integral Manifolds

C-19

Accessories

Manifolds
Kidney Flange / Eccentric Flange
C-23

Bleed Valves C-24

Calibration Fittings C-24

The Auxiliary Installation for Manifolds and Transmitters of Different Brands


Rosemount, EJA, Honeywell and SIEMENS Transmitters C-25
C-04 Gauge Valves and Instrumentation Manifolds

Gauge Valves
GV Series, GVH Series and GR Series
Features
Working pressure up to:
Stainless steel: GV, GR up to 6000 psig (414 bar)
GVH up to 10000 psig (690 bar)
GV Series and GVH Series working temperature:
PTFE packing: -65 F to 450 F (-54 C to 232 C)
Graphite packing: -65 F to 1200 F (-54 C to 649 C)
GR Series working temperature:
Acetal seat: -20 F to 250 F (-28 C to 121 C)
PEEK seat: -20 F to 400 F (-28 C to 204 C)
Non-rotating lower stem, ball tip and plug tip designs
Variety of materials for seat and packing
Safety back seating seals in fully open position
Rolled spindle operating threads
Lubricant for stem thread isolated from the media
Externally adjustable gland
Bonnet locking pin fitted as standard
Low torque operating T bar handle
Option for different colored handles
Steady and durable fastening of the handle by double lock-pins
Each GV/GR Series gauge valve leak tested with nitrogen/air at the maximum working pressure, each
GVH Series gauge valve leak tested with water at 1.1 times the maximum working pressure

Standard Materials of Construction


Ball Tip Design Valves (GV, GVH)
Valve Body Material 1
Item Component 316 SS 2
Material Grade/ASTM Specification 3
4
1 Handle 6061/B211
5
Stainless steel 6
2 Set Screw
Manifolds

7
3 Packing Bolt 304 SS/A479 8
9
4 Upper Stem 316 SS/A479 10
11
5 Lock Nut Stainless steel

6 Bonnet 316 SS/A479

7 Gland 316 SS/A479


Plug Tip Design Valves (GR)
8 Packing PTFE or graphite
1
9 Lock Pin Stainless steel 2

3
Hardened
10 Lower Stem 4
316 SS/A479
5
316 SS/A479 6
11 Body
316 SS/A182 7
8
12 Seat Acetal or PEEK 9
10
Lubricant Molybdenum disulfide-based 11
12
Process interface valves for sour gas service are available. Materials are selected in accordance with
NACE MR0175/ISO 15156. Contact FITOK Group or our authorized distributors if you have any request.
Gauge Valves and Instrumentation Manifolds C-05

Pressure vs. Temperature


GV Series Ball Tip Design Gauge Valves GVH Series Ball Tip Design Gauge Valves

Temperature (C) Temperature (C)

-54 38 149 260 371 482 593 704 -54 38 148 260 371 482 593 704
6500 448 11000 758
316 SS
6000 414 10000 690
5500 379 9000 620
5000 345 8000 552
4500 310 316
7000 483

Pressure (psig)

Pressure (bar)
SS
Pressure (psig)

4000 276

Pressure (bar)
6000 414
3500 241
5000 345
3000 207
4000 276
2500 172
3000 207
2000 138
2000 137
1500 103
1000 69 1000 69

500 35 0 0
-65 100 300 500 700 900 1100 1300
0 0
-65 100 300 500 700 900 1100 1300 Temperature (F)

Temperature (F)

Based on graphite packing.

GR Series Plug Tip Design Gauge Valves

Temperature (C)

-54 -18 38 93 149 204 260 316 371


6500 448
316 SS
6000 414

5500 379

5000 345

4500 310

4000 276
Pressure (psig)

Manifolds
Pressure (bar)

3500 241

3000 207

2500 172

2000 138

1500 103

1000 69

500 35
0 0
-65 0 100 200 300 400 500 600 700

Temperature ( F)

1. For manifolds of Acetal seat, the maximum medium temperature is 250F ( 121C), not recommended for temperature higher than
200F (93C) for water and steam application.
2. Based on PEEK seat and PTFE packing.
C-06 Gauge Valves and Instrumentation Manifolds

Types and Dimensions


Standard Type

Basic Ordering Number Design Inlet/Process Outlet/Instrument Test/Vent/Plug


GV -NS8-FNS8 Plug
Ball Tip Isolate
GVH-NS8-FNS8 1/2 Male NPT 1/2 Female NPT 1/2 Female NPT
Process Instrument
GR -NS8-FNS8 Plug Tip
GV -NS12-FNS8 Test/Vent
Ball Tip
GVH-NS12-FNS8 3/4 Male NPT 1/2 Female NPT 1/2 Female NPT
GR -NS12-FNS8 Plug Tip

(31.75)
1.25"
2.97" 1.50"
(75.4) (38.1)
5.38" 1.25"
(137.0) (31.75)

Lagging Extension Body Type

Plug
Basic Ordering Number Inlet/Process Outlet/Instrument Test/Vent/Plug Isolate
GV-NS8-FNS8-E Process Instrument
GVH-NS8-FNS8-E 1/2 Male NPT 1/2 Female NPT 1/2 Female NPT
Test/Vent
GR -NS8-FNS8-E
(31.75)
1.25"

4.84" 1.50"
(123.0) (38.1) 1.25"
7.25" (31.75)
(184.0)
Manifolds

Lagging extension body is inserted through pipe insulation.

Miniature Type

Basic Ordering Number Inlet/Process Outlet/Instrument Vent Isolate


Process Instrument
GV-NS8-FNS8-C
GVH-NS8-FNS8-C 1/2 Male NPT 1/2 Female NPT Vent stem
Vent
GR -NS8-FNS8-C
3.22"
(81.9)

(28.6)
1.13"

3.69" 1.13"
(93.7) (28.6)
Ordering Number Description

GRSS - NS8 - FNS8 - CPW - GR - SF2

Body Outlet Outlet Special Cleaning and


Series Inlet Type Inlet Size Body Style Seat Material Tip Material Packing Material Handle
Material Type Size Application Packaging

SS 316 SS FNS Female NPT 8 1/2" Same as Standard Same GV Same as PTFE Black
GV Type Body GV Aluminum NO FC-01
Ball Tip
6L 316L SS NS Male NPT 12 3/4" Inlet as Body Series
Design Series Bar
S4 304 SS FRT Female BSPT 20 M20 x 1.5 Acetal W Stellite G Graphite
GVH Specify in the C Miniature GR Red S NACE F2 FC-02
4L 304L SS RT Male BSPT same way as Type Series D5 Duplex 2205 MR0175
P PEEK PTFE GR R Aluminum
321 SS Female inlet type and Extended TI Titanium Gr.4 Series Bar
GR Plug Tip S1 E Type
Design Duplex Metric size A20 Alloy 20
D5 2205
FMS Thread
Alloy 600 M 321
(for RP) INC Stainless
Titanium HC Alloy C-276 Steel Bar
TI Gr.4 Male Metric
MS Thread
A20 Alloy 20 (for RG)
M Alloy Female BSPP
400 FRP (for RP)
INC Alloy
600
HC Alloy
C-276
B Brass
CS Carbon
Steel
904L 904L SS
Note: "Ordering Number Description" is a reference to understand the combination rules of FITOK product
part number. Not all combinations are available.

Cleaning and Packaging:


FC-01: Standard cleaning and packaging for general industrial procedures.
FC-02: Special cleaning and packaging for wetted system components to ensure compliance with
product cleanliness requirement as stated in ASTM G93 Level C.
Gauge Valves and Instrumentation Manifolds C-07

Manifolds
C-08 Gauge Valves and Instrumentation Manifolds

Instrumentation Manifolds
Features
Working pressure up to:
Stainless steel: 2D, 2R, 3D, 3R, 5D, 5R up to 6000 psig (414 bar)
2DH, 2RH, 3DH, 3RH, 5DH, 5RH up to 10000 psig (690 bar)
Alloy C-276: 2D, 2R, 3D, 3R, 5D, 5R up to 6000 psig (414 bar)
Working temperature:
PTFE packing: -65 F to 450 F (-54 C to 232 C)
Graphite packing: -65 F to 1200 F (-54 C to 649 C)
Orifice: 0.157" (4.0 mm)
Two-piece stem design: Upper stem threads cold rolled and
hardened lower stem for high strength and smooth operation
Upper stem thread lubricant isolated from system media
Linear instead of rotary motion of the rising, non-rotating stem
minimizes packing abrasion and reduces the friction between
the seat and the tip
Safety back seating seals in fully open position
Steady and durable fastening of the handle by double lock-pins
Each 2D/2R/3D/3R/5D/5R Series manifold leak tested with nitrogen/air at the
maximum working pressure, each 2DH/2RH/3DH/3RH/5DH/5RH Series
manifold leak tested with water at 1.1 times the maximum working pressure

Pressure vs. Temperature


2D, 2R, 3D, 3R, 5D, 5R Series 2DH, 2RH, 3DH, 3RH, 5DH, 5RH Series

Temperature (C)
Temperature ( C)
Manifolds

-54 38 149 260 371 482 593 704 -54 38 148 260 371 482 593 704
6500 448 11000 758
6000 414 10000 690
5500 Al 379 9000 620
lo
5000 y 345
C- 8000 552
31 27
4500 6S 6 310
Pressure (bar)

S 7000 316 483


Pressure (psig)

Pressure (bar)

SS
Pressure (psig)

4000 276
6000 414
3500 241
5000 345
3000 207
4000 276
2500 172
3000 207
2000 138
1500 103 2000 137

1000 69 1000 69
500 35 0 0
0 -65 100 300 500 700 900 1100 1300
0
-65 100 300 500 700 900 1100 1300 Temperature (F)
Temperature (F)

1. Based on graphite packing.


2. Contact FITOK Group or our authorized distributors for curve graph of other materials.
Gauge Valves and Instrumentation Manifolds C-09

Standard Materials of Construction

Valve Body Material


1
Item Component 316 SS Alloy C-276 2
Material Grade/ASTM Specification 3
1 Handle 6061/B211 4
5
2 Set Screw Stainless steel 6
304 SS/A479 7
3 Packing Bolt
8
4 Upper Stem 316 SS/A479 9
5 Lock Nut Stainless steel 10
11
6 Bonnet 316 SS/A479 Alloy C-276/B574
7 Gland 316 SS/A479
8 Packing PTFE or Graphite
9 Lock Pin Stainless steel Handle colors indicate function:
Hardened BLACK=Isolate/block
10 Lower Stem Alloy C-276/B574
316 SS/A479 RED=Test/vent
316 SS/A479 GREEN=Equalize
11 Body Alloy C-276/B564
316 SS/A182
Lubricant Molybdenum disulfide-based

Process interface valves for sour gas service are available. Materials are selected in accordance with
NACE MR0175/ISO 15156. Contact FITOK Group or our authorized distributors if you have any request.

Design Standards
Instrumentation manifolds are designed and manufactured in accordance with ANSI B31.1 and B31.3,
as well as MSS-SP-105. Flange design meets the requirements of MSS SP-99.
2-valve manifold is used with pressure gauges or pressure transmitters.
3-valve and 5-valve manifolds are used with differential pressure transmitters.

Types and Dimensions


2-valve Manifolds
Consist of one block valve and one bleed valve

Manifolds
Basic Ordering Number Inlet/Process Outlet/Instrument Test/Vent
2D -FNS8-A
1/2 Female NPT Flange 1/4 Female NPT
2DH -FNS8-A

2.13"
(54.0)
Instrument
P
T
(76.0)
3.00"

1.62"
(41.2)

Isolate Test/Vent
0.47"
4x
( 12.0)
0.83"
(21.0)

1.73" 1.18" Process


1.25"
(32.0) (44.0) (30.0)
4.37"
(111.0)

Notes: 1. Every manifold is supplied with one PTFE sealing ring for manifold-to-instrument and four 7/16" UNF x 1.75" high tensile
bolts
2. Dimensions shown are for 2D Series manifolds. For dimensions of 2DH Series manifolds, please contact FITOK Group or our
authorized distributors
C-10 Gauge Valves and Instrumentation Manifolds

Basic Ordering Number Inlet/Process Outlet/Instrument Test/Vent


2D -FNS8-L 1/2 Female NPT Flange 1/4 Female NPT

2x 0.47" 1.30"

1.62"
(41.2)
( 12.0) (33.0)
Instrument
P
T
(63.5)
2.50"

Isolate Test/Vent

1.25" 2.13"
(54.0) Process
(32.0)
2.68"
(68.0)

Every manifold is supplied with one PTFE sealing ring for manifold-to-instrument and two 7/16" UNF x 1.75" high tensile bolts.

Basic Ordering Number Inlet/Process Outlet/Instrument Test/Vent


2D-FNS8-V 1/2 Female NPT Flange 1/4 Female NPT

1.25"
(32.0)
(47.8)
1.88"

Test/Vent
3.81"
(96.8)

Instrument
0.28"

P Process
T
( 7)

Isolate
2x

1.62" 1.63"
(41.2)
(41.4)
2.44"
(62.0)

Every manifold is supplied with one PTFE sealing ring for manifold-to-instrument and two 7/16" UNF x 24 mm high tensile bolts.
Manifolds

Basic Ordering Number Inlet/Process Outlet/Instrument Test/Vent


2D -FNS8-H 1/2 Female NPT Flange 1/4 Female NPT
1.25"
(32.0)

2x 0.47"
( 12.0)
Instrument
P
T
(63.5)
2.50"
1.62"
(41.2)

Isolate Test/Vent

1.18"
(30.0) Process
3.50"
(88.9)
7.83"
(198.7)

Every manifold is supplied with one PTFE sealing ring for manifold-to-instrument and two 7/16" UNF x 1.75" high tensile bolts.
Gauge Valves and Instrumentation Manifolds C-11

Basic Ordering Number Inlet/Process Outlet/Instrument Test/Vent


2D-F-H Flange Flange 1/4 Female NPT

(31.75)
1.25"
2x 0.47" 1.00"
( 12.0) (25.4)
Instrument
P
T

(41.2)
1.62"
Isolate Test/Vent

1.18"
(30.0) Process
3.50"
(88.9)
7.83"
(198.7)

Every manifold is supplied with one PTFE sealing ring for manifold-to-instrument and two 7/16" UNF x 1.75" high tensile bolts.

Basic Ordering Number Inlet/Process Outlet/Instrument Test/Vent


2R -FNS4-A
1/4 Female NPT 1/4 Female NPT 1/4 Female NPT
2RH -FNS4-A

2x 0.28"
( 7.0)
Test/Vent
2.05"
(52.5)

Instrument
P
(29.3)
1.15"

T Process
Isolate

1.08" 1.38" 0.53"


(27.5) (35.0) (13.5)
2.44"

Manifolds
(62.0)

Dimensions shown are for 2R Series manifolds. For dimensions of 2RH Series manifolds, please contact FITOK Group or our
authorized distributors.

Basic Ordering Number Inlet/Process Outlet/Instrument Test/Vent


2R -FNS4-C 1/4 Female NPT 1/4 Female NPT 1/4 Female NPT

0.87"
(22.0)
Instrument
P
T
2.32"
(58.9)

0.28" Isolate Test/Vent


( 7.0)

1.12" 1.06 " Process


(28.4) (26.9)
2.00"
(50.8)
C-12 Gauge Valves and Instrumentation Manifolds

Basic Ordering Number Inlet/Process Outlet/Instrument Test/Vent


2R -FNS8-L 1/2 Female NPT 1/2 Female NPT 1/4 Female NPT

1.38"
0.34"

(49.0)
1.93"
2x (35.0)
( 8.5)
Instrument
P

2.32"
(58.9)
T

Test/Vent Isolate

2.00" 1.12" Process


(50.8) (28.4)

Basic Ordering Number Inlet/Process Outlet/Instrument Test/Vent


2R -FNS8-NS8-H
1/2 Female NPT 1/2 Male NPT 1/4 Female NPT
2RH -FNS8-NS8-H

2R -NS8-H
1/2 Male NPT 1/2 Male NPT 1/4 Female NPT
2RH -NS8-H
(117.6)
4.63"

Instrument
P Test/Vent
T

Isolate

Process
1.25" 1.25"
(31.75) (31.75)

Dimensions shown are for 2R Series manifolds. For dimensions of 2RH Series manifolds, please contact FITOK Group or our
authorized distributors.
Manifolds

Basic Ordering Number Inlet/Process Outlet/Instrument Test/Vent


2R -FNS8-V 1/2 Female NPT 1/2 Female NPT 1/4 Female NPT

2x 0.24"
( 6.0)

Instrument
P
T
(50.0)
1.97"
2.44"
(62.0)

Test/Vent Isolate

Process
1.08" 2.07"
(27.5) (52.5)
Gauge Valves and Instrumentation Manifolds C-13

3-valve Manifolds
Consist of two block valves and one equalizer valve

Basic Ordering Number Inlet/Process Outlet/Instrument


3D -FNS8-A
1/2 Female NPT Flange
3DH-FNS8-A

3D -FL8-A 1/2'' FITOK Flange

0.47" Instrument
4x

(41.2)
1.62"
( 12.0) D
P
1.38"
(35.0) Equalize
(64.0)
2.52"

Isolate Isolate

1.18" Process
1.25"
(32.0) (30.0)
2.13"
(54.0)
3.74"
(95.0)

Notes: 1. Every manifold is supplied with two PTFE sealing rings manifold-to-instrument and four 7/16" UNF x 1.75" high tensile bolts.
2. FL8 connections are obtained by adding an extra CM tube fitting to the FNS8 connections.
3. Dimensions shown are for 3D Series manifolds. For dimensions of 3DH Series manifolds, please contact FITOK Group or our
authorized distributors.

Basic Ordering Number Inlet/Process Outlet/Instrument Test/Vent

3D -FNS8-L 1/2 Female NPT Flange Optional

3D -FL8-L 1/2'' FITOK Flange Optional

Instrument Manifolds
4x 0.47" D
( 12.0) P
Plug Plug
(76.0)
3.00"

Equalize
1.62"
(41.2)

Isolate Isolate
0.83"
(21.0)

1.18" Process
(30.0)
1.25"
2.13"
(32.0) (54.0)
4.33"
(110.0)
5.60"
(142.0)

Notes: 1. Every manifold is supplied with two PTFE sealing rings for manifold-to-instrument and four 7/16" UNF x 1.75" high tensile bolts.
2. FL8 connections are obtained by adding an extra CM tube fitting to the FNS8 connections.
C-14 Gauge Valves and Instrumentation Manifolds

Basic Ordering Number Inlet/Process Outlet/Instrument Test


3D-FNS8-V 1/2 Female NPT Flange Optional

2x 0.28" Isolate Plug


( 7)

2.13"

3.38"
1.14"

(54)

(86)
(29)

Process Equalize D
P Instrument

Isolate Plug

1.25"
3.74" (32.0)
(95.0) 1.62"
(41.2)
2.40
(61)

Every manifold is supplied with two PTFE sealing ring for manifold-to-instrument and four 7/16" UNF x 24 mm high tensile bolts.

Basic Ordering Number Inlet/Process Outlet/Instrument Test


3D-F-V Flange Flange Optional

2.13"
(54)
1.14"
21/4 NPT

(29)
Manifolds

Instrument
D
P

Equalize
3.74"
(95)

Isolate Isolate

Process
0.28"
2 x ( 7)
47/16-20 UNF

2.13"
1.62" (54)
(41.2) 3.38"
2.44" (86)
(62.0)

Every manifold is supplied with two PTFE sealing ring for manifold-to-instrument and four 7/16" UNF x 24 mm high tensile bolts.
Gauge Valves and Instrumentation Manifolds C-15

Basic Ordering Number Inlet/Process Outlet/Instrument Test


3R -FNS8-V
1/2 Female NPT 1/2 Female NPT Optional
3RH -FNS8-V

3R -FL8-V 1/2'' FITOK 1/2'' FITOK Optional

(16.0)
0.63" 0.69" 0.28"
2x
(17.5) ( 7.0)

Instrument
D
(63.5)
2.50"

P
Plug Plug
Equalize

2.13" Isolate Isolate


1.20"
(30.5) (54.0)
3.50" Process
(88.9)

Notes: 1. FL8 connections are obtained by adding an extra CM tube fitting to the FNS8 connections.
2. Dimensions shown are for 3D Series manifolds. For dimensions of 3DH Series manifolds, please contact FITOK Group or our
authorized distributors.

5-valve Manifolds
1. 5-valve Manifold of Double-bleed Function:
consist of two block valves, two bleed valves and one equalizer valve

Basic Ordering Number Inlet/Process Outlet/Instrument Test


5D -FNS8-A
1/2 Female NPT Flange 1/4 Female NPT
5DH-FNS8-A

5D -FL8-A 1/2'' FITOK Flange 1/4 Female NPT

Manifolds
Instrument
D
P
(41.2)
1.62"
(76.0)
3.00"

Equalize
Test/ Isolate Test/
0.75"

Vent
(19.0)

Vent
4 x 0.47"
( 12.0) Process
1.25" 1.18"
(32.0) (30.0)
2.13"
(54.0)
2.95"
(75.0)
4.33"
(110.0)
5.60"
(142.0)

Notes: 1. Every manifold is supplied with two PTFE sealing rings for manifold-to-instrument and four 7/16" UNF x 1.75" high tensile bolts.
2. FL8 connections are obtained by adding an extra CM tube fitting to the FNS8 connections.
3. Dimensions shown are for 5D Series manifolds. For dimensions of 5DH Series manifolds, please contact FITOK Group or our
authorized distributors.
C-16 Gauge Valves and Instrumentation Manifolds

Basic Ordering Number Inlet/Process Outlet/Instrument Test/Vent


5D-FNS8-V 1/2 Female NPT Flange 1/4 Female NPT
2.44"
(62.0)

(41.2)

(32.0)
1.62"

1.25"
Isolate
Process

Test/Vent

Instrument DP Equalize Vent

Test/Vent
3.38"
(85.9)
2.13"

2.13"
1.14"

Process
(54)

(29)

(54)

Isolate

2x 0.28"
( 7)

4.48"
(114)

Every manifold is supplied with two PTFE sealing ring for manifold-to-instrument and four 7/16" UNF x 24 mm high tensile bolts.

Basic Ordering Number Inlet/Process Outlet/Instrument Test/Vent


5R -FNS8-L
1/2 Female NPT 1/2 Female NPT 1/4 Female NPT
5RH -FNS8-L

5R -FL8-FNS8-L 1/2'' FITOK 1/2 Female NPT 1/4 Female NPT


Manifolds

Instrument
D
P

Equalize
3.00"
(76.0)

Test/ Isolate Test/


Vent Vent
Process
1.18" 1.25"
(30.0) (32.0)
2.13"
(54.0)
2.95"
(75.0)
4.33"
(110.0)
5.60"
(142.0)

Notes: 1. FL8 connections are obtained by adding an extra CM tube fitting to the FNS8 connections.
2. Dimensions shown are for 5R Series manifolds. For dimensions of 5RH Series manifolds, please contact FITOK Group or our
authorized distributor.
Gauge Valves and Instrumentation Manifolds C-17

Basic Ordering Number Inlet/Process Outlet/Instrument Test/Vent


5R -FNS8-V 1/2 Female NPT 1/2 Female NPT 1/4 Female NPT

Instrument
2x 0.34"
( 8.6)
(28.7)
1.13"

Test/Vent Test/Vent

(91.9)
3.62"
Equalize
Isolate Isolate

2.13"
(54) Process
3.38"
(85.9)

2. 5-valve Custody Transfer/Fiscal Metering Manifold (double-equalizer):


consist of two block valves, one bleed valve and two equalizer valves

Basic Ordering Number Inlet/Process Outlet/Instrument Vent Test

5D-FNS8-AB 1/2 Female NPT Flange 1/4 Female NPT Optional

5D-FL8-AB 1/2'' FITOK Flange 1/4 Female NPT Optional

Instrument
D
1.62"
(41.2)

P
Plug Plug
Equalize Equalize
3.00"
(76.0)

Isolate Test/ Isolate


Vent
4 x 0.47"
( 12.0)
0.75"

2.13" Process Vent Process


(19.0)

1.25" (54.0)
(32.0)
4.33"
(110.0)
5.60"
(142.0)

Notes: 1. Every manifold is supplied with two PTFE sealing rings for manifold-to-instrument and four 7/16" UNF x 1.75" high tensile bolts.
2. FL8 connections are obtained by adding an extra CM tube fitting to the FNS8 connections.

Manifolds
Basic Ordering Number Inlet/Process Outlet/Instrument Vent Test
5D-FNS8-VB 1/2 Female NPT Flange 1/4 Female NPT Optional
(62.0)

(41.2)
1.62"
2.44"

Plug
Isolate
Process

2x 0.28" Equalize
( 7)
1/4 NPT Test/Vent
Instrument D P Vent
(85.9)

1.14"
3.38"

2.13"

2.13"
(54)

(54)
(29)

Equalize
Isolate
Process

Plug

4.48"
(114)

Every manifold is supplied with two PTFE sealing ring for manifold-to-instrument and four 7/16" UNF x 24 mm high tensile bolts.
C-18 Gauge Valves and Instrumentation Manifolds

Basic Ordering Number Inlet/Process Outlet/Instrument Vent Test


5D-F-VB Flange Flange 1/4 Female NPT Optional

47/16-20 UNF

(41.2)
1.62"

2.44"
(62.0)
1/4 NPT Vent Plug
Isolate
Process

Equalize
2x 0.28" Test/Vent
( 7)
Instrument DP Vent

Equalize

Process
2.13"

1.14"

2.13"

3.38"
(29)

(54)

(86)
(54)

Isolate
Plug

21/4 NPT

3.74"
(95)

Every manifold is supplied with two PTFE sealing ring for manifold-to-instrument and four 7/16" UNF x 24 mm high tensile bolts.

Basic Ordering Number Inlet/Process Outlet/Instrument Test/Vent


5R -FNS8-VB 1/2 Female NPT 1/2 Female NPT 1/4 Female NPT

Instrument
Manifolds

1.13" D
P
(28.7)

Equalize Equalize
(91.9)
3.62"

Isolate Test/Vent Isolate


2 x 0.34"
( 8.6)

1.31" Process Vent Process


2.13"
(33.3)
(54)
3.38"
(85.9)
Gauge Valves and Instrumentation Manifolds C-19

Basic Ordering Number Inlet/Process Outlet/Instrument Vent Test


5R-FNS8-AB 1/2 Female NPT 1/2 Female NPT 1/4 Female NPT Optional

5R-FL8-FNS8-AB 1/2'' FITOK 1/2 Female NPT 1/4 Female NPT Optional

Instrument
D
P
Plug Plug
3.00"
(76.0)

Equalize Equalize

Isolate Test/ Isolate


Vent
2.13"
1.25" (54.0) Process Vent Process
(32.0) 4.33"
(110.0)
5.60"
(142.0)

FL 8 connections are obtained by adding an extra CM tube fitting to the FNS8 connections.

C Integral Manifolds

C Integral Manifold is specifically designed for the pressure transmitters of Rosemountcoplanar, including Model 3051C,
3051S, 2024 and 3095. It can be assembled directly to transmitters, eliminating the need for flanges.
Each of the following manifolds contains four 7/16" UNF x 2" high tensile bolts.

Basic Ordering Number Inlet/Process Outlet/Instrument Test/Vent


2D -FNS8-C
1/2 Female NPT Flange 1/4 Female NPT
2DH -FNS8-C

Instrument
2.13" 4x 0.47" P
( 12.0) T
(54.0)

Manifolds
Isolate Test/Vent
(76.0)
3.00"

(41.2)
1.62"

Process

1.18"
(30.0)
3.35"
(85.1)
4.37"
(110.0)
C-20 Gauge Valves and Instrumentation Manifolds

Basic Ordering Number Inlet/Process Outlet/Instrument Test/Vent


3D -FNS8-C
1/2 Female NPT Flange Optional
3DH -FNS8-C
3D -FL8-C 1/2'' FITOK Flange Optional

Instrument
D
P
Plug plug
Equalize
1.30"
(33.0) Isolate Isolate
3.00"
(76.0)

1.62"
(41.2)
4x 0.47" Process
( 12.0) 1.18"
(30.0)

2.13"
1.25" (54.0)
(32.0) 3.35"
(85.0)
5.60"
(142.0)

Basic Ordering Number Inlet/Process Outlet/Instrument Test/Vent


5D -FNS8-C
1/2 Female NPT Flange 1/4 Female NPT
5DH -FNS8-C
5D -FL8-C 1/2'' FITOK Flange 1/4 Female NPT

4x 0.47"
( 12.0) Instrument
D
1.30" P
(33.0)
1.62"
(41.2)
(76.0)
3.00"

Equalize
1.18"
(30.0)
Test/ Isolate Test/
Vent Vent
2.13"
(54.0)
Manifolds

1.25"
(32.0) 3.35" Process
(85.0)
4.02"
102.0
5.60"
(142.0)

Dimensions shown are for 2D/3D/5D Series manifolds. For dimensions of 2DH/3DH/5DH Series manifolds, please contact FITOK Group
or our authorized distributors.
FL8 connections are obtained by adding an extra CM tube fitting to the FNS8 connections.
Gauge Valves and Instrumentation Manifolds C-21

Manifold Bracket Supports


SS-M2P-2BK SS-M2P-4BK
1. The integral assembly includes: bracket, U-bolts, bolts, 1. The bracket support is available for horizontal or vertical installation
gaskets, nuts 2. The integral assembly includes: bracket, U-bolts, bolts, gaskets, nuts
2. Fits with 2R-XX-A, 2R-XX-C, 3. Fits with 2D-XX-A, 2D-XX-L, 2D-XX-H,
2R-XX-L, 2RH-XX-A 3D-XX-A, 3D-XX-L, 5D-XX-A, 5D-XX-AB,
5R-XX-L, 5R-XX-AB, 2DH-XX-A, 3DH-XX-A,
3.54'' 5DH-XX-A, 5RH-XX-A
(90.0) 2.13''
2.80'' (54)
(71.0)

1.54''
(39.0)
(47.0)
1.85''

1.38''
(35)

1.18''
(30)
(30.0)
1.18"

(71.0)
2.80''

(155.0)
6.10''
2.80''
(71.0)
3. SS-M2P-2BK-50 fits with
2R-XX-V
4. SS-M2P-2BK-17.5 fits with
3R-XX-V
5. SS-M2P-2BK-28.7 fits with
3.54'' 0.39''
5R-XX-VB (90.0) (10.0)

SS-M2P-6BK SS-M2P-8BK
1. The integral assembly includes: bracket, U-bolts, 1. The bracket support is available for horizontal or vertical installation
bolts, gaskets, nuts 2. The integral assembly includes: bracket, U-bolts, bolts, gaskets, nuts
2. Fits with 2D-XX-C, 3D-XX-C, 3. Fits with 2D-XX-A, 2D-XX-L, 2D-XX-H,
5D-XX-C, 2DH-XX-C, 3DH-XX-C, 2D-XX-V, 3D-XX-A, 3D-XX-L, 5D-XX-A, 5D-XX-AB
5DH-XX-C

3.35''
(85)

Manifolds
1.18''
1.18''

1.18''
(30)

(30)

(30) 1''
(113.0)
4.45''

(25.4)
0.79''
(20.0)
(106.0)
4.17''

2.80'' 0.79''
(70.0)
2.76''

(71.0)
(20.0)
6.5''
(165.0)

2.80''
(71.0)
2.80''
(71.0)

4.13''
(105.0)

For more installation information regarding other manifolds, please contact FITOK Group or our authorized distributors.
Manifolds

Ordering Number Description

3DSS - FNS8 - LG - ETY - 1M - SF2

Packing For direct mount only Cleaning


Manifold Mount Body Outlet Outlet Test Test Mounting Special
Inlet Type Inlet Size Body Style Sealing Flange Bolt Flange Outlet and
Series Type Material Type Size & Vent & Plug Bracket Application Packaging
Material Fasteners Material Centerline

SS 316 SS FNS Female NPT 4 1/4" D type: Angle Test and No 7/16 - 20 2.13" NO
2 2-valve D A No FC-01
Flange Pattern vent UNF x 1.75" (54 mm)
3 3-valve Direct 6L 316L SS FRT Female BSPT 8 1/ 2" 1/4 Female
Mount Compact sharing one S NACE
R type: port T NPT with Y Yes 7/16 - 20 2.19" MR0175 F2 FC-02
5 5-valve DH S4 304 SS Female 12 3/4"
C Pattern 1 UNF x 3" 56 (55.6 mm)
Metric Same as Relief Valve
4L 304L SS FMS Thread 20 M20 x 1.5 Inlet Valves In-Line Test and 1/4 Female 2 M10 x 40 mm
R L vent 57 2.25"
(for RP) Mounted (57.2 mm)
Remote S1 321 SS Specified in E separated P NPT with 3 M12 x 40 mm
Mount Duplex Flange the same way Valves Plug
RH D5 F
2205 as the inlet H Horizontally
C-22 Gauge Valves and Instrumentation Manifolds

type and size Mounted


Titanium Zinc Plated
TI
Gr.4 Valves PTFE Carbon Steel
A20 Alloy 20 V Vertically
Mounted G Graphite M Stainless steel
M Alloy 400
INC Alloy 600
HC Alloy
C-276
Notes:
B Brass
1.To order 5-valve manifolds with double-equalize function, add B to the Body Style of the manifold ordering number. Example: 5DSS-FNS8-AB
CS Carbon
Steel 2.Plug options are as follow:
904L 904L SS 1) if option of test and vent sharing one port with plug is needed, add -P to the ordering number. Example: 5DSS - FNS8 - AB - P;
2) If option of test and vent separating with a plug to the test port is needed, add -EP to the ordering number. Example: 5DSS - FNS8 - AB - EP;
3) If option of test and vent separating with plug for each port is needed, add -E2P to the ordering number. Example: 5DSS - FNS8 - AB - E2P.
3. The standard center line distance of direct mounting flange outlet of 3-valve manifold and 5-valve manifold is 2.13" (54 mm).
Center line distance of 2.188" (55.6 mm) is suitable for range 6 and 7, 1151 series transmitter.
Center line distance of 2.250" (57.2 mm) is suitable for range 8, 1151 series transmitter.
4. The standard configuration of direct mounting manifold contains PTFE flange seal ring and 7/16-20 UNF X 1.75" high tensile bolts, can be connected
with transmitters under main brands, such as EJA, Honeywell, Foxboro 843 d/p, and Rosemount151, 2024, 3051H series.
5. 7/16-20 UNF x 3" high tensile bolts can be supplied, can be used for coplanar mounting of the Rosemount3051C transmitter with process flange
and the manifold.
6. Cleaning and Packaging:
FC-01: Standard cleaning and packaging for general industrial procedures.
FC-02: Special cleaning and packaging for wetted system components to ensure compliance with product cleanliness requirement
as stated in ASTM G93 Level C.
7. "Ordering Number Description" is a reference to understand the combination rules of FITOK product part number. Not all combinations are available.
Gauge Valves and Instrumentation Manifolds C-23

Accessories
Kidney Flanges and Eccentric Flanges
Features
Working temperature:
PTFE: -65 F to 450 F (-54 C to 232 C)
Graphite: -65 F to 1200 F (-54 C to 649 C)
Integral forged body
Standard material: A182 F316

Types and Dimensions


Kidney Flanges Eccentric Flanges
1.31" 1.10"
1.31" 1.10" (33.3) (28)
(33.3) (28)

(62.2)
2.45"
(62.2)
2.45"

0.06" A
A
(1.6)

The process connection type of transmitter can be transformed to other connection types.

Ordering Information Ordering Information

Dimension Dimension
Basic Ordering Connection Type in. (mm) Basic Ordering Connection Type in. (mm)
Number and Size Number and Size

Manifolds
A A
SS-KF-FNS4 1/4 Female NPT 1.10 (28) SS-EF-FNS4 1/4 Female NPT 1.10 (28)
SS-KF-FNS8 1/2 Female NPT 1.10 (28) SS-EF-FNS8 1/2 Female NPT 1.10 (28)
SS-KF-FL8 1/2'' FITOK 2.48 (63) SS-EF-FL8 1/2'' FITOK 2.48 (63)
SS-KF-PB8 1/2 PB 2.10 (53.3) SS-EF-PB8 1/2 PB 2.10 (53.3)

A kidney flange set contains a PTFE flange seal ring and two 1. Eccentric flange needs to be ordered in whole set.
7/16 - 20 UNF high tensile bolts. 2. A whole eccentric flange set contains two eccentric
flanges, two PTFE flange seal rings and four 7/16 - 20
UNF high tensile bolts.

The Selection of Flange Seal Materials

The standard flange seal material is PTFE, graphite is an option. To order graphite flange seal material, add ''- G'' as a suffix.
C-24 Gauge Valves and Instrumentation Manifolds

Various Combinations of Eccentric Flange Set

2.13" 2.13" 2.13"


(54) (54) (54.0)

2.00" 2.13" 2.25"


(50.8) (54) (57.2)

Combinations of eccentric flange set can give different center line distances of 2.0" (50.8 mm), 2.13" (54 mm) and 2.25" (57 mm).

Bleed Valves Calibration Fittings


RB Series RBSS-NS4 Bleed Valve is used as The calibration fittings can be connected directly with the bleed
standard test/vent valve. port of transmitter so that the calibration process can be simplified.
For more information, refer to FITOK Bleed For more information, refer to FITOK Calibration Fittings.
Valve RB Series.

Chrome-plated Stem
and Tip Extend Cycle Life.
Manifolds
Gauge Valves and Instrumentation Manifolds C-25

Auxiliary Installation for FITOK Manifolds


and Transmitters of Different Brands
Model of FITOK Manifolds
3(5)DXX-XX-X 3(5)RXX-FXXX-X 2DXX-XXX-X 2RXX-FXXX-X
Model of Transmitters

Rosemount Transmitters

3051 CD X X 2 (3, 4, 5, 7, 8) X X X X A4
3051 CD X X 0 X X X X H2 (H3, H4, H7, HJ) A1
3051 CD X X 0 X X X X HK A2
3051 CD X X 0 X X X X HL A3
3051 CD X X 0 X X X X DF A5 A
3051 CG (CA) X X 2 (3, 4, 5, 7, 8) X X X X A4
3051 CG (CA) X X 0 X X X X H2 (H3, H4, H7, HJ) A1
3051 CG (CA) X X 0 X X X X HK A2
3051 CG (CA) X X 0 X X X X HL A3
3051 CG (CA) X X 0 X X X X DF A5 A
1151 D (H) P 3 (4, 5) X XX XX A1
1151 A (G) P 3 (4, 5) X XX XX A1
1151 D (H) P X X XX XX DF A5 A

EJA Transmitters
EJA1X0A-XXX0 (5) X-XXXX A1
EJA1X0A-XXX1 (2, 3, 4) X-XXXX A5 A
EJA3 (4, 5) X0A-XXX0 (5)X-XXXX A1
EJA3 (4, 5) X0A-XXX1 (2,3,4)X-XXXX A5 A

Honeywell Transmitters

STDXXX-XXA-XXX A1

STDXXX-XXH-XXX A5 A A5

Manifolds
STXXXX-XXG-XXX A1 A

STGXXX-XXA-XXX
SMXXXX-XXA-XXX A1

SMXXXX-XXH-XXX A5 A

SIEMENS Transmitters

7MF433X-XXX0 (4) X-XXXX A2 A


7MF433X-XXX2 (6) X-XXXX A1 A
7MF44 (5) 3X-XXX0 (4) X-XXXX A2
7MF44 (5) 3X-XXX2 (3, 6, 7) X-XXXX A1
7MF44 (5) 3X-XXX1 (5) X-XXXX A3

A: Connecting with fittings


A1: Connecting with flange and sealing rings, using 7/16 - 20 UNF x 1.75" bolts
A2: Connecting with flange and sealing rings, using M10 x 40 mm bolts
A3: Connecting with flange and sealing rings, using M12 x 40 mm bolts
A4: Connecting with flange and sealing rings, using 7/16 - 20 UNF x 3" bolts
A5: Remove the kidney flanges and then connect with flange and sealing rings
X: To be any designators
FITOK Group
FITOK GmbH (Headquarter)
Sprendlinger Landstr. 115, 63069 Offenbach am Main, Germany
Tel.: +49 69 8900 4498 Fax: +49 69 8900 4495

FITOK, Inc.
13843 North Promenade Blvd., Suite 750, Stafford, Texas 77477, USA
Tel.: +1 281 888 0077 Fax: +1 281 582 4051

FITOK Incorporated
Block C, Zone E, Yingtai lndustrial Park, Dalang Street,
Longhua New District, Shenzhen, 518109, China
Tel.: +86 755 2803 2500 Fax: +86 755 2803 2619

FITOK Middle East Oil Equipment Trading LLC


208-209, Makateb Building, Airport Road, P.O.Box 185412, Deira, Dubai, UAE
Tel.: +971 4 2959 853 Fax: +971 4 2959 854

info@fitokgroup.com
www.fitokgroup.com

FK-IC-GV-12-EN-170

S-ar putea să vă placă și