Easun Reyrolle-2007 - Easun Reyrolle, the Easun Reyrolle logo and any alternative version thereof are registered trade marks and service marks of Easun Reyrolle
Cutout Details PART CASE CUT OUT BEZEL Description
SIZE A B C D
01 1V 221 148 243 170 The single-phase overvoltage relay basically comprises a tapped
02 1V 346.5 148 369 170 input transformer fitted with a plug-bridge, a potentiometer, a
03 2/3V 149.5 148 170 170 level-detector and a dry-reed repeat element. When the relay
setting is exceeded, the level detector triggers and so energizes
Note:
the repeat element.
1. All dimensions are in mm
2. All dimensions are measured equidistant from centre line The single-phase undervoltage relay is similar to the above but
3. Maximum depth of equipment inside panel : 200mm is maintained operated and drops off when the monitored
voltage falls below the relay setting.
Cases Ordering Information The three-phase relays comprise of three of the above elements.
Type Case size Relay type reference
Over or Undervoltage
TEB1 with reed element only 1V
Setting range Applications
TEB1 with B element only or 1 V Case reference number
with MDDA Timer The type TEB1 relay provides either overvoltage or undervoltage
protection for 3-phase systems. The type TEB2 relay provides
TEB2 with reed element only 2/3 V Qualification
either overvoltage or undervoltage protection for single-phase
TEB2 with B element or 1V ISO 9001-2000 systems.
with MDDA Timer
The policy of Easun Reyrolle is one of continuous improvement and development. The company therefore reserves the right to supply equipment,
which may differ slightly from that described and illustrated in this publication.
Easun Reyrolle-2007 - Easun Reyrolle, the Easun Reyrolle logo and any alternative version thereof are registered trade marks and service marks of Easun Reyrolle
Cutout Details PART CASE CUT OUT BEZEL Description
SIZE A B C D
01 1V 221 148 243 170 The single-phase overvoltage relay basically comprises a tapped
02 1V 346.5 148 369 170 input transformer fitted with a plug-bridge, a potentiometer, a
03 2/3V 149.5 148 170 170 level-detector and a dry-reed repeat element. When the relay
setting is exceeded, the level detector triggers and so energizes
Note:
the repeat element.
1. All dimensions are in mm
2. All dimensions are measured equidistant from centre line The single-phase undervoltage relay is similar to the above but
3. Maximum depth of equipment inside panel : 200mm is maintained operated and drops off when the monitored
voltage falls below the relay setting.
Cases Ordering Information The three-phase relays comprise of three of the above elements.
Type Case size Relay type reference
Over or Undervoltage
TEB1 with reed element only 1V
Setting range Applications
TEB1 with B element only or 1 V Case reference number
with MDDA Timer The type TEB1 relay provides either overvoltage or undervoltage
protection for 3-phase systems. The type TEB2 relay provides
TEB2 with reed element only 2/3 V Qualification
either overvoltage or undervoltage protection for single-phase
TEB2 with B element or 1V ISO 9001-2000 systems.
with MDDA Timer
The policy of Easun Reyrolle is one of continuous improvement and development. The company therefore reserves the right to supply equipment,
which may differ slightly from that described and illustrated in this publication.