CENTRIFUGAL PUMP

SPECIFICATION SHEETS
PCLAG-4-0-P-01A/B

PAGE 4 OF 8
Doc. N: AC0041402-PB1I3-MD17006 Project No. AC0041402 PURCH ORDER NO.

1 Applicable to: Proposal Purchase As Built


2 Client: PDVSA
3 Site: "PLANTA COMPRESORA PARA LEVANTAMIENTO ARTIFICIAL POR GASService: Bombas de Transferencia de Condensado KOD
4 No. Required: 02 Size / Type: / Centrifuga No. Stages: 1
5 Pump Mfr.: Goulds o Similar Model No. / Serial No.: POR EL FABRICANTE
6 Note: Indicates Information To Be Completed by Purchaser By Manufacturer By Manufacturer or Purchaser
7 GENERAL
8 Pumps To Operate In No. Motor Driven 2 No. Turbine Driven N/A
9 Series / Parallel: Parallel Pump Item No. PCLAG-4-0-P-01A/B Pump Item No. N/A
10 Gear Item No. N/A Motor Item No. PMPCLAG-4-0-P-01A/B Turbine Item No. N/A
11 Gear Provided By N/A Motor Provided By Pump's Manufacturer Turbine Provided by N/A
12 Gear Mounted By N/A Motor Mounted By Pump's Manufacturer Turbine Mounted by N/A
13 Gear Data Sht No's N/A Motor Data Sheet No.'s N/A Turbine Data Sheet No.'s N/A
14 OPERATING CONDITIONS (5.1.3) SITE AND UTILITY DATA (CONT.)
15 Capacity, Normal 10 GPM Rated GPM Water Source
16 Other GPM Chloride Concentration (PPM)
17 Suction Pressure Max/Rated 27.63 / PSIA Instrument Air: Max/Min Pressure / PSIA
18 Discharge Pressure 88.7 PSIA
19 Differential Pressure 62.98 PSI LIQUID (5.1.3)
20 Differential Head 153.43 FT Type Or Name Of Liquid Condensados
21 Hydraulic Power 0.1 BHP NPSHD 3 FT Pumping Temperature
22 Process Variations (5.1.4) Normal 93.3 F Max F Min 93.3 F
23 Starting Conditions (5.1.4) Vapor Pressure 24.700 PSIA @ 93.3 F
24 Service: Continuous Interm. (Starts/Day) Relative Density (Specific Gravity):
25 Parallel Operation Required Normal 1 Max Min
26 SITE AND UTILITY DATA (5.1.3) Specific Heat, Cp 1 BTU/LBF
27 Location: (5.1.30) Viscosity 0.6 cP @ 93.3 F
28 Indoor Heated Under Roof Max. Viscosity cP
29 Outdoor Unheated Partial Sides Corrosive/Erosive Agent (5.12.1.9)
30 Grade Mezzanine Chloride Concentration (PPM) (6.5.2.4)
|
31 Elect. Area Class. CL 1 Gr D Div 2 H2S Concentration (PPM) (5.12.1.12c)
32 Winterization Req'd. Tropicalization Req'd. Liquids: Toxic Flammable
33 Site data: (5.1.30) Other
34 Altitude - FT Barometer 14.5 PSI
35 Range Of Ambient Temps: Min/Max 60 / 100 F PERFORMANCE
36 Relative Humidity: Min/Max 53 / 82 % Proposal Curve No. RPM
37 Unusual Conditions: (5.1.30) Dust Fumes Impeller Dia. Rated Max. Min. INCH
38 Other salt and tropical ambient with high temperature Rated Power HP Eff. %
39 Utility Conditions: (5.1.3) Minimum Continuous Flow:
40 Steam: Drivers Heating Thermal GPM Stable GPM
41 Min: PSIA F PSIA F Preferred Operating Region to GPM
42 Max: PSIA F PSIA F Allowable Operating Region to GPM
43 PSIA F PSIA F Max Head @ Rated Impeller FT
44 Electricity: Drivers Heating Control Shutdown Max Power @ Rated Impeller HP
45 Voltage 480 V NPSHR At Rated Capacity FT (5.1.10)
46 Phase 3 PH Suction Specific Speed less than 11000 (5.1.11)
47 Hertz 60 HZ Max Sound Press. Level Req'd 85 dBA @ 3 ft (5.1.16)
48 Cooling Water: (5.1.19) Est. Max Sound Pressure Level dBA (5.1.16)
49 Temp. Inlet F Max. Return F Remarks:
50 Press. Norm. PSIA Design PSIA
51 Min. Return PSIA Max. Allow DP PSIA

52 REVISION LOG
53 REVISION ISSUE STATUS DATE BY CHK'D APP'D
54 A Emisin Original 23/07/15 Y.CH. G.F. E.R.
55 B Incorporacin de Comentarios 10/08/15 Y.CH. G.F. E.R.
56 0 Emisin Final 14/08/15 Y.CH. G.F. E.R.
57
58
CENTRIFUGAL PUMP
SPECIFICATION SHEETS
PCLAG-4-0-P-01A/B
(Continued)
PAGE 5 OF 8
Doc. N: AC0041402-PB1I3-MD17006 Project No. AC0041402 PURCH ORDER NO.

1 CONSTRUCTION CONSTRUCTION (CONT.)


2 APPLICABLE STANDARD:
3 API 610 10th Edition COUPLINGS: (6.2.2)
4 Other Make Thomas, Metastream or similar
5 PUMP TYPE: (4.1) Model
6 OH2 BB1 VS1 VS6 Rating, (HP/100RPM)
7 OH3 BB2 VS2 VS7 Lubrication
8 OH6 BB3 VS3 Other Limited End Float Required
9 BB4 VS4 Spacer Length
10 BB5 VS5 Service Factor
11 Nozzle Connections: (5.4.2) (Information to be verified by Manufacturer) Driver Half Coupling Mounted By:
12 Size Rating Facing Position Pump Mfr. Driver Mfr. Purchaser
13 in Coupling Per API 671 (6.2.4)
14 Suction 2 300# RF END BASEPLATES:
15 Discharge 1-1/2 300# RF END API Baseplate Number (Annex D)
16 Bal. Drum Non-Grout Construction: (6.3.13)
17 Pressure Casing Connections: (5.4.3) Remarks:
18 No. Size (NPS) Type Dimensions: (20,76x63,78x22 ) pulg
19 in

20 Drain Flanged with valve MATERIALS (5.12.1.1)


21 Vent Self-venting
22 Pressure Gauge Annex H Class S-6 (5.12.1.1)
23 Temp Gauge Min Design Metal Temp. (5.12.4.1) 57.6 F
24 Warm-Up Barrel/Case CARBON STEEL
25 Balance/Leak-off Impeller 12% CHR
26 Cylindrical Threads required Case/Impeller Wear Rings 12% CHR HARDENED
27 CASING MOUNTING: Shaft AISI 4140
28 Centerline Near Centerline Diffusers
29 Foot Separate Mounting Plate Coupling Spacer/Hubs
30 In-Line Coupling Diaphragms (Disks)
31 CASING SPLIT: Materials per NACE MR0175
32 Axial Radial Remarks: Manufacturer shall review the materials proposed.
33 CASING TYPE:
34 Single Volute Multiple Volute Diffuser
35 Overhung Between Bearings Barrel
36 CASE PRESSURE RATING: BEARINGS AND LUBRICATION
37 Max. Allowable Working Pressure PSIA BEARING: (TYPE / NUMBER)
38 @ F
39 Hydrotest Pressure PSIA Radial
40 Suction Press. Regions Must Be Designed For MAWP Thrust
41 ROTATION: (Viewed From Coupling End) Review And Approve Thrust Bearing Size
42 CW CCW LUBRICATION: (5.11.3, 5.11.4)
43 Impellers Individually Secured Grease Flood Ring Oil
44 Remarks: Flinger Purge Oil Mist Pure Oil Mist
45 Constant Level Oiler Preference (5.10.2.2)
46 Bolt OH3 Pump To Pad/Foundation Pressure Lube Sys. API-610 API-614
47 SHAFT: Oil Visc. ISO Grade
48 Shaft Diameter At Coupling INCH Oil Heater Req'd Electric Steam
49 Shaft Diameter Between Brgs. INCH Oil Pressure To Be Greater Than Coolant Pressure
50 Span Between Bearings Ctr Line INCH Remarks:
51 Span Between Bearing & Impeller INCH 1.- DE ACUERDO A LAS ESPECIFICACION BOMBAS DE CONDENSADOS KOD,
52 Remarks: DOCUMENTO N AC0041402-PB1I3-MD16009.
53
54
55
CENTRIFUGAL PUMP
SPECIFICATION SHEETS
PCLAG-4-0-P-01A/B
(Continued)
PAGE 6 OF 8
Doc. N: AC0041402-PB1I3-MD17006 Project No. AC0041402 PURCH ORDER NO.

1 MECHANICAL SEAL OR PACKING MECHANICAL SEAL OR PACKING (CONT.)


2 SEAL DATA: SEAL FLUSH PIPING (Cont.)
3 See Attached API-682 Data Sheet Piping Assembly:
4 Non-API-682 Seal Threaded Unions Socket Welded
5 Seal Code BSTFN Flanged Tube Type Fittings
6 Seal Manufacturer John Crane, Burgmann or Flowserve Pressure Transmitter (Plan 52/53) Type
7 Size And Type Pressure Gauge (Plan 52/53)
8 Manufacturer Code Level Transmitter (Plan 52/53 Type
9 SEAL CHAMBER DATA: Level Gauge (Plan 52/53)
10 Temperature F Temperature Indicator (Plans 21, 22, 23, 32, 41, 52)
11 Pressure PSIA Heat Exchanger (Plans 52/53)
12 Flow GPM Remarks
13 Seal Chamber Size Mechanical Seals and API Plan shall be according with Standard
14 Total Length INCH Clear Length INCH API 682, Third Edition.
15 SEAL CONSTRUCTION: PACKING DATA:
16 Sleeve Material Manufacturer
17 Gland Material Type
18 Aux. Seal Device non sparking floating throttle bushing Size No. of Rings
19 Jacket Required Packing Injection Required
20 GLAND TAPS: Flow GPM @ F
21 Flush (F) Drain(D) Barrier/Buff. (B) Lantern Ring

22 Quench (Q) Cooling (C) Lubrication (G) STEAM AND COOLING WATER PIPING
23 Heating (H) Leakage Pumped Fluid (P) Cooling Water Piping Plan (6.5.3.1)
24 Balance Fluid (E) External Fluid Injection (X) Cooling Water Requirements
25 SEAL FLUIDS REQUIREMENT AND AVAILABLE FLUSH LIQUID: Seal Jacket/Brg. Hsg. GPM @ PSIA
26 Note: If Flush Liquid Is Pumpage Liquid (As In Flush Piping Plans 11 to 41), Plan 23 Seal Heat Exchanger GPM @ PSIA
27 Following Flush Liquid Data Is Not Required. Plan 52 Seal Heat Exchanger GPM @ PSIA
28 Supply Temperature Min/Max / F Total Cooling Water GPM
29 Relative Density (Specific Gravity) @ F Steam Piping: Tubing Pipe
30 Name of Fluid Remarks:
31 Specific Heat BTU/LBF
32 Vapor Pressure PSIA @ C

33 Hazardous Flammable Other INSTRUMENTATION


34 Flow Rate Min/Max / GPM VIBRATION:
35 Pressure Required Min/Max / PSIA Noncontacting (API 670) Transducer
36 Temperature Required Min/Max / F Provision For Mounting only (5.10.2.11)
37 BARRIER/BUFFER FLUID: Flat Surface Req'd (5.10.2.12)
38 Supply Temperature Min / Max / F See Attached API-670 Data Sheet
39 Relative Density (Specific Gravity) @ F Monitors and Cables
40 Name of Fluid Remarks:
41 Vapor Pressure PSIA @ F
42 Hazardous Flammable Other
43 Flow Rate Min/Max / GPM TEMPERATURE AND PRESSURE:
44 Pressure Required Min/Max / PSIA Radial Brg. Metal Temp Thrust Brg. Metal Temp.
45 Temperature Required Min/Max / F Provision For Instruments Only
46 QUENCH FLUID: See Attached API-670 Data Sheet
47 Name of Fluid Temperature Gauges (with Thermowells)
48 Flow Rate GPM Other:
49 SEAL FLUSH PIPING: Pressure Gauge Type
50 Seal Flush Piping Plan 11 Location
51 Tubing Carbon Steel Remarks:
52 Pipe Stainless Steel
53 Auxiliary Flush Plan 61
54 Tubing Carbon Steel
55 Pipe Stainless Steel
CENTRIFUGAL PUMP
SPECIFICATION SHEETS
PCLAG-4-0-P-01A/B
(Continued)
PAGE 7 OF 8
Doc. N: AC0041402-PB1I3-MD17006 Project No. AC0041402 PURCH ORDER NO.

1 SPARE PARTS (TABLE 18) OTHER PURCHASER REQUIREMENTS


2 Start-Up Normal Maintenance Coordination Meeting Required
3 Specify Vendor shall supply a list of recommended spare pa Review Foundation Drawings
4 for Two (2) years of Normal Operation. Review Piping Drawings
5 Observe Piping Checks
6 Observe Initial Alignment Check
7 MOTOR DRIVER (6.1.1/6.1.4) Check Alignment At Operating Temp.
8 Manufacturer Loher, ABB, Siemens, Reliance or Similar Check Design Approval
9 0.4 HP RPM Rigging Device Req'd For Type OH3 Pump
10 Horizontal Vertical Hydrodynamic Thrust Brg Size Review Req'd
11 Frame Lateral Analysis Req'd
12 Service Factor 1.0 Rotor Dynamic Balance
13 Volts/Phase/Hertz 480 V / 3 PH / 60 HZ Mount Seal Reservoir Off Baseplate
14 Type Induction Installation List In Proposal
15 Enclosure TEFC Spare Rotor Vertical Storage
16 Minimum Starting Voltage Torsional Analysis/Report
17 Temperature Rise Class "B" - 80 C Progress Reports Required
18 Full Load Amps Remarks:
19 Locked Rotor Amps
20 Insulation Class "F"
21 Starting Method
22 Lube Grease QA INSPECTION AND TEST
23 Vertical Thrust Capacity Review Vendors QA Program
24 Up LBF Down LBF Performance Curve Approval
25 Bearings (Type/number): Shop inspection (7.1.4)
26 Radial Test with Substitute Seal (7.3.3.2b)
27 Thrust Test Non-Wit Wit Observe
28 Remarks: Electric Motor Power to be verified by Manufacturer. Hydrostatic (7.3.2)
29 1.-Electric Motors shall be designed according with Standard Performance (7.3.3) (1 Each)
30 PDVSA N-251 "Technical Specification for TEFC Squirrel Cage NPSH (7.3.4.2)
31 Induction Motors 370 KW (500 HP) and below". Complete Unit Test (7.3.4.3)
32 Sound Level Survey (7.3.4.4)
33 SURFACE PREPARATION AND PAINT Cleanliness Prior To
34 Manufacturer's Standard Final Assembly (7.2.2.2)
35 Other AC0041402-PB1I3-MD16002 nozzle Load Test (6.3.6)
"ESPECIFICACIONES DE PINTURA Y REVESTIMIENTOS"
36 PUMP: Brg. Hsg. Resonance
37 Pump Surface Preparation Test (7.3.4.6) (One pump)
38 Primer Remove/Inspect
39 Finish Coat / Color Hydrodynamic Bearings
40 BASEPLATE: (6.3.17) Amer Test
41 Baseplate Surface Preparation Auxiliary Equipment
42 Primer Test (7.3.4.5)
43 Finish Coat / Color Routine Test for motor
44 SHIPMENT: (7.4.1)
45 Domestic Export Export Boxing Reqd. Material Certification Required (5.12.1.8)
46 Outdoor Storage More Than 6 Months Casing Impeller Shaft
47 SPARE ROTOR ASSEMBLY PACKAGED FOR: Other
48 Horizontal Storage Vertical Storage Casing Repair Procedure Approval Required (5.12.2.5)
49 Type Of Shipping Preparation
50 Remarks: Inspection Required For Connection Welds (5.12.3.4e)
51 Pumps shall be grey color Mag. Particle Liq. Penetrant
52 Electric Motors shall be blue c(RAL-6017) Radiographic Ultrasonic
53 Inspection Required For Castings (7.2.1.3/5.12.1.5)
54 WEIGHTS (ESTIMADOS) Mag. Particle Liq. Penetrant
55 Motor Driven: Radiographic Ultrasonic
56 Weight Of Pump 750 LBS Additional Inspection Required for:
57 Weight Of Baseplate 150 LBS seal auxiliary piping of API Plan 11/61
58 Weight Of Motor 500 LBS Mag. Particle Liq. Penetrant
59 Total Weight 1400 LBS Radiographic Ultrasonic
CENTRIFUGAL PUMP
SPECIFICATION SHEETS
PCLAG-4-0-P-01A/B
(Continued)
PAGE 8 OF 8
Doc. N: AC0041402-PB1I3-MD17006 Project No. AC0041402 PURCH ORDER NO.

1 QA INSPECTION AND TEST (CONT.) GENERAL REMARKS (CONT.)


2 Alternate Acceptance Criteria (see Remarks)
3 Hardness Test Required for:
4 (7.2.2.3)
5 Wetting Agent Hydrotest
6 Vendor Submit Test Procedures (7.3.1.2/9.2.5)
7 Record Final Assembly Running Clearances
8 Inspection Check-List (7.1.6)
9 Remarks:
10
11
11
12 GENERAL REMARKS
1.-) If diference between NPSHA and NPSHR is less than 1 meter,
13 Manufacturer shall.
14 include NPSH Test, Non Witness.