FOR
BASIS (ASSUMED)
.
Item / Parameter AFBC CFBC Difference Remarks
Fuel feeding system Either underbed or Overbed Overbed feeding is recommended
overbed or both in heavy rain fall area for AFBC.
Boiler height Appx. 22 to 25 meters. Apr. 42 to 44
meters
Inbed evaporator coils Provided to keep the There are no inbed
bed temp. below coils. Temp. is
desired level controlled by
higher heat `X`
coefficient, which
is achieved by
increasing the
solids density in
the furnace shaft.
Space requirement Space
requirement is
not very
different for
AFBC or
CFBC.
Control & instrumentation Simple Simple CFBC requires
Few additional
controls loops
than AFBC
Boiler capacity on Indian high ash coal. Can be offered upto Can be offered
140 to 150 TPH from 50 or 60
maximum. TPH to any high
capacity say 300
TPH or more.
Installation cost of boiler Lower Higher CFBC
installation cost
of only boiler is
Apr. 50 to 60 %
higher than
CFBC
Delivery & commissioning schedule < 18 months < 22 months