Sunteți pe pagina 1din 8

OMICRON Monitoring Solutions

Partial discharge monitoring of high voltage assets

M/G
Extending the service life of high-voltage assets

Why monitoring? OMICRON monitoring technology across the


complete asset life cycle
Insulation degradation in critical high-voltage (HV)
equipment can lead to failure. Monitoring helps to predict
severe failure and to extend the service life of equipment.

In asset management there is a clear trend away from


expensive time-based maintenance toward cost-effective,
condition-based maintenance: Manufacturing Commissioning
> Continuous or periodic monitoring of HV equipment
is an essential tool for effective maintenance
management Manufacturing Commissioning
> Monitoring answers questions about the present Test Test
condition of the equipment and its future performance
> The large amount of real-time data gathered by Temporary / Periodic
Monitoring Solutions T
monitoring systems can be used for precise insulation
condition assessment
> Effective comparison of historical data is enabled via an Continuous
easy-to-use and extendable database solution Monitoring Solutions
> Exact knowledge of insulation state at any time saves
money, as maintenance schedules can be specifically
optimized and the service life of assets can be extended

Why partial discharge monitoring?


Partial discharge (PD) phenomena are a consequence of
local electrical stress concentration in electrical insulation.
PD activity can lead to failure and serious consequent
damage as well as to faults in critical elements of the
power network.
Therefore it is mandatory to identify the presence of PD
activities and to monitor PD tendencies.
PD is a widely-accepted measuring parameter for insulation
diagnosis. PD measurements are specified for type, routine
and on-site tests for most HV assets.
The large variety of PD signals makes PD measurement and
Monitoring can prevent serious damage detection a challenging task. OMICRON monitoring systems
to critical high-voltage assets employ advanced noise supression techniques for reliable
PD source recognition.

2
Preventing Early Failure Ensuring Reliable Operation Extending Lifetime

Temporary Monitoring Periodic Condition-Based Monitoring

Continuous Monitoring

Why OMICRON monitoring technololgy?


For more than 10 years, OMICRON has delivered PD measurement solutions for manufacturing and commissioning purposes.
Now this leading-edge digital technology is also available for in-service monitoring applications.
OMICRON solutions cover all requirements from periodic to continuous monitoring of HV apparatus. Their flexible, modular
system design allows these solutions to be easily adapted to specific customer requirements for monitoring data analysis.

Your benets
> Proven PD diagnostic technology now also available
for periodic and continuous monitoring
> Reliable and accurate PD monitoring results provide
current state of insulation condition
> Knowing insulation condition helps optimize asset
management and investment planning
> Optimized asset management saves money and
extends reliable service life

3
OMICRON monitoring system components

Asset Sensor Acquisition Unit

Data Pre-Processing

Signal Synchronization

Trend Analysis

HV assets OMICRON sensors are especially PD acquisition unit characteristics


monitored designed for the decoupling of > Clear discrimination between PD and external
> HV Cables PD signals on different HV assets. interference and efficient separation of multiple
OMICRON offers a broad range of PD sources using 3PARD and 3CFRD
> Generators &
PD sensors.
Motors > Reliable fault localization and fault-type recognition
> Power Inductive, high frequency current > Wide bandwidth of PD measurements
Transformers transformers (HFCT) are designed for
> Fully digital PD monitoring in one compact enclosure
PD detection on HV cable accessories
> HV GIS/GIL > Synchronous processing of PD signals
like cross-bonding joints and
terminations. > Designed for rough environments (IP67 enclosure)

Capacitive couplers of different > Extremely reliable, maintenance free, no moving parts
rated voltages are available for PD > Reliable power protection for long-term field
monitoring on rotating machines. application in substation and cable tunnel
environments
For power transformers, OMICRON
offers robust tap adapters for different
types of bushings.

4
Central Computer & Monitoring Software

Fibre optic connection

Backup

Reporting Tool
Data Analysis
Alerting

PD Source Determination
Expert Analysis

Interface Management
@ Notification

Web-client

Central computer & monitoring


software The monitoring software
runs on a central computer. It can
be directly accessed from the central
computer or an other computer in the
trusted network via the convenient
web-based interace. The monitoring
software is a management tool for
system configuration, continuous
data acquisition and archival, as well
Separation of PD sources by 3CFRD
as for visualizing both real-time and
archived measurement data.
Analyzed data provided by OMICRON monitoring systems helps utility maintenance
teams and asset managers to make accurate decisions about asset life management
based on comparable and reliable data. PD data is visualized and evaluated using
highly sophisticated and unique OMICRON PD source separation techniques.

5
Dedicated support for your monitoring needs

Why OMICRON monitoring solutions High-quality support at every stage


are different of your project
Our monitoring systems are not only a set of excellent We start the implementation of your monitoring system by
system components and technology. Our knowledged understanding your needs and challenges. With this input,
experts are working for you to support you in all stages the system can be designed according to your needs. Our
of your monitoring project. team of specialists then installs the system for you on-site.
In simple words: We provide you with peace of mind while During the commissioning of the system, its performance
matching the actual needs of your HV equipment over its and measurement sensitivity are verified. You are then
operational lifetime. trained on how to use the system and take maximum
advantage of its features.
The measured data is stored, processed and visualized by
the monitoring software. Our high-voltage experts are
available to help you interpret and analyze the data. We
can also provide you regular asset condition reports and
recommendations for further action.

Flexibility Competence Knowledge


Project-specific monitoring system design On-site monitoring system installation, Customer training in system
to match your requirements calibration & commissioning operation and data analysis

6
Monitoring project knowledge and expertise
you can rely on
> Evaluation of monitoring requirements
> Project-specific monitoring system design
> Integration of monitoring system into existing infrastructure
> Installation, commissioning and calibration of the monitoring system
> Monitoring system and data evaluation training
> Dielectric failure analysis and follow-up based on monitoring data
> High-voltage expert assistance
> Worldwide customer service & hotline

Availability Expertise
Worldwide customer support, system Support in condition assessment and
upgrades & HW/SW maintenance data evaluation

7
OMICRON is an international company serving the electrical power industry with
innovative testing and diagnostic solutions. The application of OMICRON products
allows users to assess the condition of the primary and secondary equipment on
their systems with complete confidence. Services offered in the area of consulting,
commissioning, testing, diagnosis and training make the product range complete.

Customers in more than 140 countries rely on the companys ability to supply leading-
edge technology of excellent quality. Service centers on all continents provide a broad
base of knowledge and extraordinary customer support. All of this together with our
strong network of sales partners is what has made our company a market leader in the
electrical power industry.

The following publications provide further information on the solutions described in this brochure:

OMS 605 Portable PD Monitoring of PD Monitoring of MONTRANO Continuous


PD Monitoring System Rotating Machines HV Cable Systems Monitoring System for
Power Transformers

For more information, additional literature, and detailed contact information of our worldwide
offices, please visit our website.

OMICRON L2290, January 2014


www.omicron.at | www.omicronusa.com Subject to change without notice.

S-ar putea să vă placă și