Sunteți pe pagina 1din 4

CORUS

Gas Volume Converter


KEY BENEFITS
T, PT, PTZ Gas Volume Converter
Conforms to European Standard
EN 12405-1 and EN 12405-1/A1
MID approval
CORUS is an electronic volume converter dedicated to commercial
ATEX approval for installation in
and industrial applications. It converts the actual volume measured hazardous area (zone 0)
by the gas meter to reference conditions. Thus, CORUS is a key Large integrated database
element in the whole Itron chain, from the meter to billing data. Compressibility according to AGANX19,
S-GERG, AGA 8 (gross or detailed
methods) or Table of Z
CORUS uses the measured working values CORUS is built in an IP65 enclosure, for RS 232 and optical port for
of volume, pressure and temperature to wall or meter mounting. Thanks to its local / distant communication
provide: accurate piezo-resistive pressure sensor
High accuracy on the whole
the converted volume and its 4 wires PT1000 temperature
temperature / pressure range
probe, CORUS provides an accurate
the conversion factor Autonomous or external power supply
conversion on the whole temperature
the compressibility factor range. Large graphic display
(several formulas available) Possibility to download new firmware
CORUS non-metrological firmware can
a large database in the field
be updated in the field without stopping
pulse retransmission Internal optional slot for Ex:
operations and without breaking the
metrological seals (MID). Its large PSTN modem
DESCRIPTION RS-485 ports (x2)
integrated database can be customised
The volume registered by the meter is to fit the customers needs. Recorded 2nd pressure sensor input
converted to reference conditions using data and number records can be freely
the formula : set.
Pm Tb Zb
Vb = Vm CORUS is the base element of a
Pb Tm Zm complete and extremely flexible system,
Terminology perfectly adaptable to the customers
requirements:
Vm unconverted volume registered
by the meter Consumption, pressure, temperature
monitoring through its large database
Vb converted volume in reference
for billing purposes
(base) conditions
RS 232
Monitoring functions for gas stations
Tm gas temperature in operating conditions External Power Supply
Remote reading solutions through (Option)
Tb reference (base) temperature Digital Input 2
PSTN, GSM, GPRS or TCP/IP with or Digital Output 2
Pm gas pressure in operating conditions several integrated communication Digital Input 1
Pb reference (base) pressure protocols: or Digital Output 1
Meter Cable (LF1 / LF2 / Tamper)
Zm compressibility factor in operating IEC-62056-21 (IEC-61107) T Probe
conditions MODBUS RTU P Sensor
Zb compressibility factor in reference Connection slot (option)
IDOM
(base) conditions Inputs / Outputs

SPECIFICATIONS knowledge to shape your future


TECHNICAL FEATURES Accuracy
According to EN12405, overall accuracy
Approvals
on conversion factor is better than 0.5 %
MID: at reference conditions and better than
Module B T10323 1 % at rated operating conditions.
Module D PTB approval Typical accuracy better than 0.2 %
Metrology: approval according
Display and Keyboard
to EN12405-1 and EN12405-1/A1
(European Standard) Graphic display
ATEX: device of category 1 approved All metrologic data and alarm status
to be used in hazardous area zone 0, available
ia IIC T4 classification (zone1, ia e mb Translatable messages to any language
DELTA meter with CORUS IIC T4 classification with internal PSTN Specifics icons for application
modem) (see page 3)
CE Marking: compliant with 89/336/ Possibility to show graphs for P, T, Z, C,
EEC (EMC), 94/9/EC (ATEX) and Qm, Qb, P2
2004/22/EC (MID Directive)
5-Button keyboard
Temperature Sensor Possibility to program main parameters
Platinum PT 1000 (1000 at 0 C) probe by keyboard

Class A accuracy according to EN60751 Possibility to display the whole database

Casing: stainless steel tube for insertion Digital Inputs (On/Off1, On/Off2,
into a thermowell ( 6 mm) Tamper)
Cable length: 2.5m or 0.8 m Station monitoring
Normally open or normally closed
Pressure Sensor
programmable status
Absolute pressure sensor designed for
Connection to any On/Off signal type
CORUS application (gauge pressure
(Station door contact, safety valve
sensors available on request)
position, pressure switch,..) in hazardous
Silicon piezo-resistive sensor areas.
FLUXI 2000 meter with CORUS Overpressure up to 150 % of Pmax
Available in 3 ranges: Digital Outputs

0.9 to 10 bar absolute 2 Digital, isolated ouputs fully


programmable as:
3 to 30 bar absolute
Unconverted volume pulse retransmission
7.2 to 80 bar absolute
Converted volume pulse retransmission
Connection adapter: 1/4 BSP (Gas) male
Alarm retransmission
Typical Accuracy: <0.15 %rd over the
whole pressure range 4/20 mA output (through an external F/I
Ex module)
Volume Input
Alarms
Dry contact, passive LF Reed type switch
The following alarms are managed by the
Maximum frequency 2Hz
CORUS:
Accessories Programmable input pulse weight
Temperature (Min, Max, Sensor failure)
Configuration software (Wincor) (0.001, 0.01, 0.1, 1, 10, 100)
Pressure (Min, Max, Sensor failure)
Thermowell Second LF input for coherence function
Conversion factor (Min, Max)
3-Way pressure connection kit Associated tampering detection input
Unconverted and converted flow-rate
Optical head Cyble sensor ATEX module
(Min, Max)
ISB+ Compressibility Coherence
External supply Ex module Main formulas available: Interval consumption
F/I Converter for 4/20 mA output S-GERG Tamper
Additional boards: AGA8 Gross method 2 On/Off 1 and On/Off 2
PSTN modem AGA8 Detailed method External power supply outage
RS-485 ports (x2) AGANX19 Warning thresholds (T, P, P2)
2nd pressure sensor input AGANX19 modified
Cyble sensor ATEX module Table of Z (16 coefficients formula)
Fixed Z (PT conversion)
SYSTEM OVERVIEW

Distant communication (Connection to CORUS RS 232 or RS 485 port)

GSM/GPRS data collection through FOCUS+ GSM/GPRS Modem


HAZARDOUS AREA SAFE AREA

CORUS FOCUS+ Supervisor+

Direct connection to standard devices (RTU, TCP/IP interface, standard modem, PC...)

Supply
+9/24 VDC

RS-232 RS-232
RTU or RS-485 ISB+ CORUS
SAFE AREA HAZARDOUS AREA

Distant communication through internal RS-485 board (up to 4 CORUS on the same bus)
SAFE AREA HAZARDOUS AREA
RTU or modem with RS-485 port CORUS CORUS
ISB+
Graphic Display
CORUS CORUS
Possibility to translate messages

INDEX VALUE ALARM DATA CONFIG


RS-485 RS-485

Unconverted volume :
19348725.000 m3
Distant communication through internal Ex PSTNModem
Converted volume :
24284651.283 Nm3
Graphic display function

INDEX VALUE ALARM DATA CONFIG


4.2

1 2

Upstream pressure monitoring with P2 internal board Local communication


4.0
through optical port P (bar) 4.025
Gas regulator CORUS
Specific icons for CORUS applications

Battery supply mode and status


P2 External supply mode and status
Volume
Alarm presence (active, memorized)
Optical Head
Upstream Incoming pulse from meter
pressure
PC Pressure alarm (active, memorized)
Temperature alarm (active, memorized)
Meter (Delta/Fluxi) Note book Communication in progress
Technical Specifications Dimensions
Overall Accuracy of the Maximum Error < 0.5 % - Typical Error < 0.2% 222
C Factor 206
Conversion Range Pressure: 0.9 bar to 80 bar - Temperature: according Z formula
Power Supply Battery or external (through Ex module)
Autonomy 5 years (battery version) in typical conditions

42
145
Ambient Temperature -25 C to +55 C
Range

59
Enclosure IP65 polycarbonate box
4 holes 28 20
Volume Input LF input (2Hz max); Reed switch type or Cyble sensor ATEX module 5.2
Second input for coherence function 86
Temperature Sensor PT1000 class A; 4 wires 49

Pressure Sensor [0.9 /10] bara, [3 /30] bara and [7.2 /80] bara
Ranges (gauge pressure sensors available on request)
Pressure Sensor Type Piezo-resistive sensor
Outputs 2 Channels fully configurable as pulse, alarm or 4/20 mA*
User Interface Graphic display +5 button keyboard
Communication Optical serial port and RS232 serial port 25
Metrol. Cables Length 2.5 m
(P, T, LF)
Option Internal Ex PSTN modem (V32bis)
RS-485 dual port board
P2 second pressure input board
* through external F/I converter
HAZARDOUS AREA SAFE AREA
DATABASE External power:
CORUS provides 6 different logs: External Ex specific supply module
Hourly log: last 1440 hours (2 months) required providing 6 to 12 V DC to the
Daily log: last 124 days (4 months) CORUS
CORUS

Monthly log: last 24 months Main battery (16.5 A.h) remains in the
Interval log: product, acting as backup battery in L 20 m
Ex isolator Volume pulse
or alarm

from 3100 to 5900 records according case of mains cuts. 220 V AC


or 24 V DC
Volume pulse
selected data L 20 m
BSI
Ex isolator
BSI
or alarm
220 V AC
interval programmable from 1 to 60 mn or 24 V DC

Events log: last 800 events Configuration with pulse outputs


Parameters log: last 200 records Information to be specified
when ordering:
POWER SUPPLY Pressure range
HAZARDOUS AREA SAFE AREA

Battery operating or external supply Formula for Z calculation


mode (mains or solar)
LF input cable type OK

Battery:
Specific 16.5 A.h lithium battery pack Battery or external supply CORUS 9 V DC Ex 220 V AC
Power Module or 24 V DC
including all required protections for Metrologic cables length F/I 4/20 mA
intrinsic safety Language for display L 10 m Converter
220 V AC
Data 1*

Pack can be changed in hazardous or 24 V DC

Accessories F/I 4/20 mA


area without interrupting the normal L 10 m Converter Data 2*

MID sealing
220 V AC
operation of the device or 24 V DC
* P, T, Qu or Qc
5 years autonomy in typical conditions
Configuration with 4 / 20 mA outputs

Our company is the worlds leading provider of smart metering, data collection and utility software systems, with over
8,000 utilities worldwide relying on our technology to optimize the delivery and use of energy and water.
To realize your smarter energy and water future, start here: www.itron.com

ITRON FRANCE
For more information, contact your local sales representative or agency:
Rue des Temps Modernes - BP 23
86361 Chasseneuil-du-Poitou Cedex
France
Phone: +33 (0)5 49 62 70 00
Fax: +33 (0)5 49 62 70 89

While Itron strives to make the content of its marketing materials as timely and accurate as possible, Itron makes no claims, promises, or guarantees about the accuracy, completeness,
or adequacy of, and expressly disclaims liability for errors and omissions in, such materials. No warranty of any kind, implied, expressed, or statutory, including but not limited to
the warranties of non-infringement of third party rights, title, merchantability, and fitness for a particular purpose, is given with respect to the content of these marketing materials.
Copyright 2012, Itron. All rights reserved. GA-CORUS-EN-V2.1-2012.11

S-ar putea să vă placă și