All steel framing to comply with

Aust Standards AS 3623


Roof Pitch subject to +/- 1 degree tolerance
Refer to engineers report for all structural elements
Control joints as specified by
engineer defined by: CJ

aprox. location of
community m/box
Boundary: 36.58 m by builder

90 (19.55 m) 4618 (17.03 m) 90


6840

in e
NOTE: free standing garden

ivis osed
1105

nl
tap to be located above

i io
P.O.S.= 81.07 m

su prop
m)
sewer flood gully

LONGVIEW CRESCENT
bd
11
7510

(9.
NOTE:
NO BRUSH FENCE WILL
BE ERECTED WITHIN 3m
OF THE DWELLING 3088 ceiling
steps by owner
3088 ceiling

Boundary: 16.76 m
LOWER LOWER

688mm 688mm SPLIT


NOTE: SPLIT
2400 ceiling
2400 ceiling
SITE BOUNDARIES TO HIGHER
HIGHER
Site Plan

on boundary
(12.00 m) garage built
BE CONFIRMED BY FINAL
Boundary: 19.81 m

SURVEYORS PLAN PROPOSED


NEW GAR LOT 275 Weeks Macklin Homes
RESIDENCE
Plot Date 21/11/2012 1:19 PM P:\05 Weeks Macklin\42046\wd_42046_v6.0_B.cad

David & Susan Rowett


1080
Lot 275, No.4
Briardale Road,
135 OHalloran Hill

5035
m
3960
3480

32
3000

. Job No. Drawing No. Rev


:4
ry
90 (14.87 m) (18.66 m) 135 n da 42046 WD01 B
u
Boundary: 33.53 m Bo Areas - M2 Scale 1:200
Date 19-Oct-2012
Drawn JL
BRIARDALE ROAD Total Sheet 06
Checked KF

Sales Rep: Jonathan Borrelli


Amendments
A - 6/11/12 OM Framing changes req'd. Amendment as per
variation requested 05/11/12
B - 21/11/12 KF no framing changes req'd, site plan updated

Version No. 6.00.036 - 13


Do not scale drawings, dimensions take preference over
scale. Contractors to verify dimensions prior to
commencement of building work. These drawings are
the exclusive property of the Week Group of Companies.
Any reproduction without written authority is prohibited.
Copyright C
13790
GENERAL NOTES 5760 7430 600
X - external wall mounted taps to be
tap fixed 600mm above brick rebate 240 3400 75 1200 75 2200 240
- man hole to be trimmed on site 240 6950 240
mh (position is nominal only)
- hard wired smoke detector with 240 3590 75 2950 75 3500 75 3045 240
s battery back up
- laundry troughs adjacent sliding 240 3590 75 1000 75 800 75 1000 75 3500 75 3045 240
doors to have min. 150mm gap. 240 3590 75 6525 75 3045 240
tiled hobs to all showers
weather seals to external doors 5150 610 5150 1450 830 All steel framing to comply with
by builder Aust Standards AS 3623
2100hi o/h c/b canopy 2100hi Roof Pitch subject to +/- 1 degree tolerance
- denotes control joint as per w/ 300 deep r/hd with gyprock Refer to engineers report for all structural elements
engineering tap Control joints as specified by
b/head above lintel wall engineer defined by: CJ
X 2125x1450-SD15-2

240

240
240
240
dp PVC dp
(600) NOTES:

(600)
NOTE: 1000 LITRE MIN RAINWATER tr

1430
HOUSE DESIGN - OWNER DESIGN

150
TANK AS PER COUNCIL REQUIREMENTS f
OR AS OTHERWISE NOTED WITH PUMP extend bench top hp SPECIFICATION - VALUE PLUS
wo with joiners 1200

2150
kit900 LAND TITLE: COMMUNITY TITLE

900
& BALL FLOAT DEVICE, CONNECTED into window (no X r/water tank
dual oven pantry l'dry wm

2700
1205x850asw
TO ONE WC BY OWNER STANDARD BRICK - 230 x 110 x 76
bottom reveal) outlet prov.

3710
850
CEILING INSULATION - R4.0

250 650
BUILDER TO ALLOW FOR FIRST FIX (INCL. GARAGE)
PLUMBING PROVISION FOR A SEPERATE dwp

820
(2275) EXTERNAL INSULATION -

660
RAINWATER RUN PLUMBED TO ONE
R2.0 SOUNDSCREEN

e
WC & A MAINS WATER POINT FOR

in

75
6240

6240
900 TILES TO ENTRY, KIT &

ry l
BALL FLOAT DEVICE

6035
flat b/bar LIVING AREAS BY OWNER

nda
by joiner CARPET TO BEDROOMS & ROBES

2125x3060-SD31-3
DOWNPIPE NOTES:

bou
downpipes shown on plan are family BY OWNER

1800x1810asw
nominal in location and may be 3060 GARAGE BUILT ON BOUNDARY
moved in accordance with 3088 CL

1810

3260
engineering plan or by the Cladding Type Colorbond

9280
roofing contractor.
steps by owner internal steps
3088 ceiling as per 3088 ceiling Roof Pitch 25
KEY:
(denotes downpipe as selected) LOWER 1200x 1 engineering balustrades LOWER Eave Width 450

720
7130
610 PVC
dp standard downpipe dp 2 by owner
950 240

(obsc)
PVC dp PVC downpipe up 3 dp Ceiling Height 2400/3088
240
240

240

240
75

75
688mm s 688mm SPLIT

(130)
(900)
SPLIT Window Head Height 2115/2125

(900)
NOTES:
x
p 2400 ceiling
1630

2400 ceiling x

robe
1800

1800

- Laundry, bath and ensuite to be fitted HIGHER Floor Plan - Ground


bath
1457x1450asw

with sanitary ware with overflows. HIGHER dining


15710

15710
1450
3020

- No floor trap required bed 3


75 75

(600) 720 v 2400 CL


425

linen
75 1145 75

75

- Note that the floor waste gully is to be


Weeks Macklin Homes

(200)

garage built on boundary


provided to shower alcove

820
720
s
1070
Plot Date 21/11/2012 1:19 PM P:\05 Weeks Macklin\42046\wd_42046_v6.0_B.cad

STAIR NOTES: garage


75

75
75
x
David & Susan Rowett

6970
6840
FFL-FFL = 688mm (1000)

7430
p
(1000)

820 mh
1457x1210asw

3 goings @ 250mm per going wir study 2400 CL


1210

Lot 275, No.4


1920
1920

4 risers @ 172mm per riser

2150
2150
350mm Briardale Road,
ens
9470

provide non-slip grooves or approved vented


v 720 720 OHalloran Hill

820
equiv. to treads concrete step as per solartube
5955
75
75

6635

engineers report by owner

75
75
living Job No. Drawing No. Rev
stairs as per engineering 2100hi x 2410w 42046 WD02 B

robe

1600
NOTE: free standing garden s roller door
instant bed 1 (remote)
Areas - M2 Scale 1:100
4790

tap to be located above gas hws Living


entry (600) 144.46
3900
3900

350
Date 19-Oct-2012
bed 2

75
3650
sewer flood gully 2400 CL

350
Garage 24.11
gas elec dp Total 168.57 Drawn JL

820
820
m/box brick piers to

1975
Total Sheet 06
820

2040
240

(m/box type 1) roller door


Checked KF
480
480
240

boundary line
960
830
480

480

dp
240
240

240
240
dp (2) 1800x610asw
Sales Rep: Jonathan Borrelli
1800x610asw 1800x610asw 1800x610asw 1800x610asw
Amendments
A - 6/11/12 OM Framing changes req'd. Amendment as per
1070 610 710 610 1070 240 610 230 610 350100 890 100 830 610 590 610 830 240 2410 470 variation requested 05/11/12
B - 21/11/12 KF no framing changes req'd, site plan updated
240 1815 75 1700 75 3460 75 2990 75 3045 240
240 3590 75 3460 75 2990 75 3045 240
240 3590 75 3460 75 2990 240
240 3590 75 1965 240 1090 240 2990 240
240 3590 240 3130 240 2990 240
Version No. 6.00.036 - 13
4070 2040 1090 3470 3120
13790 Do not scale drawings, dimensions take preference over
scale. Contractors to verify dimensions prior to
commencement of building work. These drawings are
the exclusive property of the Week Group of Companies.
Any reproduction without written authority is prohibited.
Copyright C
boundary line
colorbond roof @25 pitch

450 nom eaves

Ceiling

window head height

roof pitching height


2445
2400
2115
All steel framing to comply with
Aust Standards AS 3623
Roof Pitch subject to +/- 1 degree tolerance
Floor Refer to engineers report for all structural elements
Control joints as specified by
CJ
Front elevation aluminium sliding windows 2100hi x 2410w
roller door
brick piers to roller door engineer defined by:

boundary line
colorbond roof @25 pitch
nil eaves
to this side 450 nom eaves

Ceiling

window head height

roof pitching height


roof pitching height

2445
2400
2115
3133

3088

Floor aluminium sliding window steps by owner

3088 ceiling 2400 ceiling


Rear elevation aluminium sliding door
688mm SPLIT
Elevations
colorbond roof @25 pitch

450 nom eaves


Weeks Macklin Homes
Plot Date 21/11/2012 1:19 PM P:\05 Weeks Macklin\42046\wd_42046_v6.0_B.cad

Ceiling David & Susan Rowett

window head height

roof pitching height


roof pitching height

instant Lot 275, No.4


window head height

2445
2400
gas hws Briardale Road,

2115
1800
3133

3088

extend bench top OHalloran Hill


into window (no
2125

bottom reveal)
Job No. Drawing No. Rev
Floor steps by owner aluminium sliding windows gas elec 42046 WD03 B
m/box
3088 ceiling 2400 ceiling Areas - M2 Scale 1:100
Left elevation aluminium
sliding door 688mm SPLIT
(m/box type 1)
Date 19-Oct-2012
Drawn JL
colorbond roof @25 pitch Total Sheet 06
nil eaves
450 nom eaves Checked KF
to this side
Sales Rep: Jonathan Borrelli

Ceiling Amendments
roof pitching height

garage built on boundary A - 6/11/12 OM Framing changes req'd. Amendment as per


variation requested 05/11/12

roof pitching height


B - 21/11/12 KF no framing changes req'd, site plan updated

window head height


2445

2400

3133
3088
2125
Floor

Version No. 6.00.036 - 13


Right elevation 2400 ceiling 3088 ceiling
Do not scale drawings, dimensions take preference over
scale. Contractors to verify dimensions prior to
aluminium sliding window commencement of building work. These drawings are
688mm SPLIT the exclusive property of the Week Group of Companies.
Any reproduction without written authority is prohibited.
Copyright C
Steel framed trussed roof construction
40mm zincalume 'top hat' roof purlins for in accordance with manufacturers
40mm zincalume 'top hat' roof purlins for
Steel framed trussed roof construction colorbond roofs with 900mm end spans "Supaloc's" specifications.
in accordance with manufacturers and 1200mm mid span
colorbond roofs with 900mm end spans
and 1200mm mid span "Supaloc's" specifications. All steel framing to comply with
trusses fixed to studs with Aust Standards AS 3623
selected roof covering at nom. roof pitch tie down tags Roof Pitch subject to +/- 1 degree tolerance
trusses fixed to studs with
selected roof covering at nom. roof pitch tie down tags Refer to engineers report for all structural elements
guttering and fascia as specified truss pitching point Control joints as specified by
CJ
truss pitching point engineer defined by:
guttering and fascia as specified
ceiling line
ceiling line

10mm thick fibre reinforced nil eaves 10mm thick fibre reinforced
plasterboard ceiling lining
plasterboard ceiling lining
boxed eaves lined with 4.5mm
thk frct eaves lining 22mm zincalume ceiling battens 22mm zincalume ceiling battens
timber eave trimmers at 600mm max. ctrs at 600mm max. ctrs
timber moulding

eaves width
(nominal)

pitching height

pitching height
ceiling height

ceiling height
10mm thick plasterboard 10mm thick plasterboard
wall lining
wall lining
brick veneer wall construction
brick type as per specification brick veneer wall construction
and selection document nogging brick type as per specification
and selection document nogging
Brick veneer wall ties in accordance
with B.C.A. requirements Brick veneer wall ties in accordance Section Detail - Sheet 1
with B.C.A. requirements
steel stud framed wall construction
(refer to wall framing layout and
specification for details) HEIGHT NOTES steel stud framed wall construction Weeks Macklin Homes
(refer to wall framing layout and
Plot Date 21/11/2012 1:19 PM P:\05 Weeks Macklin\42046\wd_42046_v6.0_B.cad

0.5mm thick black embossed CEILING PITCHING specification for details) HEIGHT NOTES
polythene dpc to project 2400 2445 David & Susan Rowett
0.5mm thick black embossed
10mm beyond brickwork face
2700 2745 polythene dpc to project
CEILING PITCHING Lot 275, No.4
165mm wide x 25mm hi rebate 10mm beyond brickwork face 2400 2445 Briardale Road,
to slab perimeter 2700 2745 OHalloran Hill
165mm wide x 25mm hi rebate
min. distance to adjoining to slab perimeter
75

paving / path level floor level Job No. Drawing No. Rev
min. distance to adjoining
B

75
paving / path if specified
paving / path level 42046 WD04
(refer to plan for details) floor level
Areas - M2 Scale N/A
rubble under paving / path level paving / path if specified
0.2mm thick polythene damp proof (refer to plan for details) Date 19-Oct-2012
membrane under slab
Concrete footing as specified Drawn JL
by engineer rubble under paving / path level
0.2mm thick polythene damp proof
Total Sheet 06
membrane under slab
Concrete footing as specified
Checked KF
by engineer
TYPICAL WALL SECTION with EAVES Sales Rep: Jonathan Borrelli
(STANDARD BRICK - COLORBOND ROOF) Amendments
TYPICAL WALL SECTION - NIL EAVES A - 6/11/12 OM Framing changes req'd. Amendment as per
variation requested 05/11/12
B - 21/11/12 KF no framing changes req'd, site plan updated

(STANDARD BRICK - COLORBOND ROOF)

Version No. 6.00.036 - 13


Do not scale drawings, dimensions take preference over
scale. Contractors to verify dimensions prior to
commencement of building work. These drawings are
the exclusive property of the Week Group of Companies.
Any reproduction without written authority is prohibited.
Copyright C
All steel framing to comply with
water resistant substrate
Aust Standards AS 3623
Roof Pitch subject to +/- 1 degree tolerance
water resistant lining (tiles)
Refer to engineers report for all structural elements
Control joints as specified by
engineer defined by: CJ

steel wall frame

boundary line
(refer to steel framing layout)
flashing to lap over purlin
BRICK COURSE TABLES
27 courses 2322mm b/height selected roof covering at nom. roof pitch vertical corner flashing to extend
to a minimum of 1800mm high
31 courses 2666mm b/height on steel framed truss roof construction
water proof membrane to comply
with AS4858 up to 1800mm above
floor level
pitching heights
nominal 150w X 75mm deep
2445 Strip Grate 750 installed as per
(min) formed colorbond gutter
2745 manufacturers specifications
by roofing contractor
stainless steel or brass end strips
RL
BRICK RL
truss pitching point floor tiles with fall to grate to
50mm min.
height of coursing (nominal) prevent ponding

above rebate ceiling line (1:80 fall) (1:80 fall)

formed colorbond boundary 10mm thick fibre reinforced


flashing by roofing contractor plasterboard ceiling lining flexible sealant 3-5mm wide

service provisions (gas, water, 50mm wide tile with 1:80 fall
back to grate to prevent ponding
elec etc.) to pass through top plate
NOTE: height of brickwork to
boundary gutter wall to be steel framed wall construction Section Detail - Sheet 2
foam backing rod or flexible
stopped as per table above (refer to wall framing layout & sealant, 5-15mm high
seperate details for information)
Weeks Macklin Homes
BOUNDARY GUTTER for 50mm wide tile with cement sand mortar bed
Strip Grate 750 installed as per
Plot Date 21/11/2012 1:19 PM P:\05 Weeks Macklin\42046\wd_42046_v6.0_B.cad

1:80 fall back to grate manufacturers specifications


concrete recess cast

wall
David & Susan Rowett
BRICK VENEER CONSTRUCTION integrally with slab

50mm
(min)
leak/control puddle flange
Lot 275, No.4
(STANDARD BRICK - COLORBOND CLAD ROOF) Briardale Road,

50mm min. distance from


OHalloran Hill
(1:80 fall)

walls to grate edge

hob
wall
SECTION THROUGH GRATE Job No. Drawing No. Rev
42046 WD05 B
floor tiles with fall to grate Areas - M2 Scale N/A
to prevent ponding
Date 19-Oct-2012
50mm
(min) wall
Drawn JL
50mm
(min) FLOOR PLAN (Typical) Total Sheet 06
Checked KF
SHOWER DETAIL - STRIP GRATE 750
Sales Rep: Jonathan Borrelli
Amendments
A - 6/11/12 OM Framing changes req'd. Amendment as per
variation requested 05/11/12
B - 21/11/12 KF no framing changes req'd, site plan updated

Version No. 6.00.036 - 13


Do not scale drawings, dimensions take preference over
scale. Contractors to verify dimensions prior to
commencement of building work. These drawings are
the exclusive property of the Week Group of Companies.
Any reproduction without written authority is prohibited.
Copyright C
water resistant lining
water resistant substrate
impervious surface not less impervious wall surface to
than 150mm above fixture 150mm min above bench top
and extending over flange
bond breaking tape
flexible sealant 5-15mm wide steel stud
flexible sealant 3-5mm wide

flexible sealant 3-5mm wide impervious finish

sink or basin sealed to


wall notched to take flange bench top with gasket or
bath flexible sealant All steel framing to comply with
tiles on framed or block support Aust Standards AS 3623
steel studwork with bath chase wall to clear bath profile if required Roof Pitch subject to +/- 1 degree tolerance
lintel fixed across back of studs
Refer to engineers report for all structural elements
Control joints as specified by
bath chase detail wall and bench top junction engineer defined by: CJ

with inset fixture bath


Wet Area Notations
to compy with AS 3740-2003 and
additional requirements of Minister's
water-resistant substrate floor tiles to extend under wall tiles with Specification SA F1.7 2004
water resistant substrate 1:80 graded fall to floor waste SHOWER AREA (Cat. 1)
impervious surface
impervious surface not less Floor-impervious with shower tray or wet
than 150mm above fixture area membrane to comply with AS 4858
Drainage - 1:60 min grade to shower
and extending over flange
trap. Shower trays drained to flange in
flange (12mm min) shower trap
impervious floor with 1:60 graded fall waste outlet 50mm setdown
BATH and LAUNDRY
to floor
tap assembly flexible sealant 3-5mm wide floor grades to waste oulets Floor - impervious
Drainage - BATH - 1:80 min to floor
sanitary fixture trap. May be drained to shower trap
flexible sealant 3-5mm wide
where hob not used.
(May not be required if propietry flange
Drainage - LDRY - 1:80 min to trap
seals the surface between tile and substrate)
SINGLE ROOM CONTAINING WC
flexible sealant 5-10mm wide or Floor - impervious
tap penetration flange shower screen fixed Drainage - no requirement
penetrations through walls sanitary fixtures abutting walls flush with inside face
wall to be impervious NOTE: flooring to be of impervious floor
of set down or sheeting or similar approved flooring as
in shower areas inside face of hob
to a height 1800mm specified
above floor level
top of tray side 1:80 fall to waste Wet Area Detail
40x40mm flashing angle outlet waterproof membrane
glazed & grouted (PVC or metal)
shower screen tiles 50mm min screed where required 1:60 fall to
shower outlet Weeks Macklin Homes
flexible sealant
Plot Date 21/11/2012 1:19 PM P:\05 Weeks Macklin\42046\wd_42046_v6.0_B.cad

flexible sealant between between tiles


hob and wall and between shower tray or waterproof in-situ vertical corner flashing
timber must David & Susan Rowett
hob and shower screen NOT be used for membrane to comply with AS4858 (where a shower tray is used) water stop drainage outlet
hob
flexible sealant 3-5mm wide
Lot 275, No.4
waste outlet min. setdown 25mm side of shower tray 100mm Briardale Road,
mortar bed above finished shower floor
impervious wall surface
shower base with set down level (highest point)
OHalloran Hill
water resistant substrate
structural flooring Job No. Drawing No. Rev

hob at shower tray steel/steel wall junction 42046 WD06 B


Areas - M2 Scale N/A
Date 19-Oct-2012
impervious surface
water resistant substrate Drawn JL
water resistant substrate
water resistant lining Total Sheet 06
water resistant substrate
vertical corner flashing angle wall frame 100mm shorter Checked KF
shower tray or waterproof water resistant lining than standard frames
nogging to fix bottom
membrane to comply with AS4858 of wall lining vertical corner flashing angle
10x16mm hex head screws at Sales Rep: Jonathan Borrelli
flexible sealant (3 - 5mm wide) shower tray or waterproof
300mm ctrs fixing frame to RHS
membrane to comply with AS4858 Amendments
foam backing rod or flexible
flexible sealant (3 - 5mm wide) A - 6/11/12 OM Framing changes req'd. Amendment as per
sealant, 5-15mm high variation requested 05/11/12
glazed & grouted floor tiles B - 21/11/12 KF no framing changes req'd, site plan updated
fall to floor waste 100x50mm RHS trimmer flexible sealant, 3-5mm high
perimeter flashing sealed glazed & grouted floor tiles provide M12 anchor bolt
to tray or continued as 15mm min. fall to floor waste
cement sand mortar bed to centre of RHS section
shown here
fixed into concrete slab
concrete recess or hob
cast integrally with slab cement sand mortar bed
structural flooring shower tray or waterproof membrane Version No. 6.00.036 - 13
adhered to floor only foam backing rod or flexible
shower tray or waterproof membrane pre-formed shower base
sealant, 5-15mm high adhered to floor only waterproof membrane Do not scale drawings, dimensions take preference over
scale. Contractors to verify dimensions prior to
shower tray on sheet floor waterproofing of shower flexible sealant (3 - 5mm wide) waterproofing of shower commencement of building work. These drawings are
the exclusive property of the Week Group of Companies.
Any reproduction without written authority is prohibited.
wall and floor junctions floor using shower base Copyright C
All steel framing to comply with
Aust Standards AS 3623
Roof Pitch subject to +/- 1 degree tolerance
Refer to engineers report for all structural elements
Control joints as specified by
engineer defined by: CJ

s
x
x

x
mh Electrical Plan - Ground

Weeks Macklin Homes


Plot Date 21/11/2012 1:19 PM P:\05 Weeks Macklin\42046\wd_42046_v6.0_B.cad

David & Susan Rowett


s Lot 275, No.4
Briardale Road,
OHalloran Hill

Job No. Drawing No. Rev


42046 WD07 B
Areas - M2 Scale 1:100
Date 19-Oct-2012
Drawn JL
Total Sheet 06
Checked KF

Sales Rep: Jonathan Borrelli


Amendments
A - 6/11/12 OM Framing changes req'd. Amendment as per
variation requested 05/11/12
B - 21/11/12 KF no framing changes req'd, site plan updated

light point S smoke alarm t phone point ceiling fan dishwasher


DW
ELECTRICAL LEGEND & NOTATION
2-way exhaust fan single GPO ceiling fan with RH rangehood
3 20 1x20W flouro light microwave oven SMOKE DETECTORS (IN ACCORDANCE
3-way double GPO MW
diffused WITH SAE 1.7) TO BE OF THE
DIM
dimmer s/GPO 1100AFL 3 IXL fan 3 switch STV upright cooker IONISATION TYPE AND HAVE HARD Version No. 6.00.036 - 13
1x40w flouro 11
downlight diffused spa WIRED CONNECTION TO 240V AC
d/GPO 1100AFL 5 IXL fan 5 switch SPA Do not scale drawings, dimensions take preference over
11 ELECTRICAL SUPPLY AND HAVE 9V DC scale. Contractors to verify dimensions prior to
wall mounted 2x40W flouro external GPO TV point A/C air conditioning BACKUP commencement of building work. These drawings are
EXT the exclusive property of the Week Group of Companies.
light diffused TV
Any reproduction without written authority is prohibited.
Copyright C