Documente Academic
Documente Profesional
Documente Cultură
ENGINEERING
CATALOG No. 16
www.zsi-foster.com
WESTRUT
F raming C hannel S ystem
The WESTRUT Metal Framing System consists of roll formed
channel, and hundreds of channel nuts and fittings, including
pipe clamps, beam clamps, angular fittings and brackets. This
pre-engineered system enables the user/ designer to create
an astounding variety of support elements and structural
configurations.
WESTRUT systems are economical, strong, continually
adjustable and reusable, no drilling or welding is required for
normal assembly situations. Connections can be made anywhere along
the continuous slot of the channel, and all component fittings can be demounted and used again and again. All
WESTRUT products are completely compatible with other 1-58" metal framing channel systems; saving time, labor
and money.
WESTRUT basic channels consist of the eleven sizes illustrated initially on pages 6 - 7. Engineering data and actual-
size dimensional drawings are given for each section on pages 12 - 33. Basic channels are also produced with holes,
slots, and knock-outs.
WESTRUT channel configurations produce a remarkably efficient weight/strength ratio. Combination channels
provide maximum versatility, as well as strength for those demanding framing applications. Additionally, channel
is available by special order, in most any combination with two or more single sections, or with compatible
miscellaneous steel sections welded together.
Special Metals, Engineering Data, and Material Specifications are outlined starting on pages 117 - 124.
WESANCO Inc. Manufactures WESTRUT Channels and Fittings, in accordance with the guidelines and agreements
of the Metal Framing Manufacturers Association. WESANCO Inc. is a founding member of the MFMA.
WESANCO Inc. Manufactures and distributes a wide variety of quality and performance recognized Concrete Inserts
and related materials uitilized in the concrete, pre-casting industry. WESANCO Inc. Concrete inserts, have received
the accreditation of the, National Pre-Cast Concrete Association, Inc.
www.ZSi-Foster.com
2 www.wesanco.com
T able of C ontents
When entire fitting (in at least one plane) is fitted with Channel
Nuts and bolts, align Channel Nut direction (s) to correspond 2
with channel arrangement; place fitting into position.
Channel Nuts without springs should hang below, clear of
channel's in-turned edges prior to tightening the bolts.
4 www.wesanco.com
WESTRUT I nstallation
C hannel N ut W ith S pring
Insert the appropriate WESTRUT Channel Nut with
1 spring, parallel to the slot edges, anywhere along
the continuous open slot of the channel.
Properly torquing the bolt draws the Channel Nut with spring
4 up against the in-turned channel lips, forming a strong,
secure clamping connection
Use caution not to bottom the bolt (select one of sufficient
length, but not so long as to contact the inside back). Do
not over torque the bolt
3
Fitting, bracket, or accessory, is located on the channel
face over the Channel Nut with spring.
An appropriate diameter and length of bolt is inserted,
and the fitting is adjusted for location at this time
1 5 8"
3
8" 7
8" W-200
191#/CFT
9
32 " 1 5 8"
3 7
W-800
8" 8" 146#/CFT
9 1 5 8"
32 "
3 7
2 7 16 " 8" 8"
9
32 "
1 5 8"
9
32 " 9
32 " 9
32 "
7
W-900 8"
1 3 8" 12 ga, 1 5 8 " x 7 8 "
W-300
12 ga, 1 5 8 " x 1 3 8 "
MATERIAL THICKNESS
1 Product thickness conforms to tolerance
3 4 "
specified by ASTM A568
Engineering properties may vary slightly due to
permissible thickness tolerances.
Material Specification
Light gauge steel shall conform to ASTM specifications as follows:
Gauge Steel Material Current ASTM
Hot Rolled Pickled & Oiled A 1011 SS GR33
W-150 12
Galvanized A 653 SS GR33
12 ga, 1 5 8 " x 3 1 4 "
Hot Rolled Pickled & Oiled A 1011 SS GR33
14
Galvanized A 653 SS GR33
Cold Rolled Sheet A 1008 SS GR33
16
Galvanized A 653 SS GR33
19 Cold Rolled Sheet A 1008 SS GR33
6 www.wesanco.com
WESTRUT
C hannel P rofiles
14 G auge - C hannel P rofiles
Channel
W-210 W-500
Channel Nuts
& Hardware
142#/CFT 100#/CFT
1 5 8" 1 5 8"
3 7 3 3 7 3
8" 8" 8" 8" 8" 8"
Fittings
9 9
32 " 32 "
Brackets
13
W-500 16 "
14 ga, 1 5 8 " x 13
16 "
1 5 8"
Clamps
Beam
W-210
14 ga, 1 5 8 " x 1 5 8 "
Bases
Post
Caps
End
16 G auge - C hannel P rofiles
Clamps
W-400
83#/CFT
Accessories
Electrical
1 5 8"
3 7 3
8" 8" 8"
Concrete
Inserts
9
32 "
13
16 "
Cushioned
W-400
Clamping
16 ga,1 5 8 " x 13
16 "
Supports
19 G auge - C hannel P rofiles
Rooftop
W-600 W-700
Specifications
Material
36#/CFT 25#/CFT
13 13
16 " 16 "
7
7 16 "
Information
3 3
3
16 " 16 " 16 "
Design
16 " 3
16 " 3
32 "
13
32 "
Installation
3 13
32 " 16 "
W-700
13 13
19 ga, 16 " x 32 "
W-600
Index
13 13
19 ga, 16 " x 16 "
Wesanco Engineering Catalog 7
WESTRUT
C hannel C ombinations
8 www.wesanco.com
others available upon request.
9
Index Installation Design Material Rooftop Cushioned Concrete Electrical Clamps End Post Beam Brackets Fittings Channel Nuts Channel
Information Specifications Supports Clamping Inserts Accessories Caps Bases Clamps & Hardware
WESTRUT
C hannel C ombinations
Perforated Selections
Ref: Page 11 for Specific Perforation Information
Radiused Combinations
Channel
Add "SS" to channel number. Example: W-200SS
Available from stock in W-200 and W-500.
Channel Nuts
9
16" x 1-18" slots are punched on 2" centers.
& Hardware
Channel With Long Slots
Add "SL" to channel number. Example: W-200SL
Fittings
Available in W-200, W-210 and W-500.
13
32" x 3" slots are punched on 4" centers.
Brackets
Channel With Holes
Add "H" to channel number. Example: W-200H
Clamps
Beam
Available in W-200, W-210 and W-500.
9
16" holes are punched on 1-78" centers.
Bases
Post
Channel With Knock-Outs
Caps
Add "KO" to channel number. Example: W-200KO
End
Available in W-200 and W-210.
7
8" Knock-outs are punched on 6" centers.
Clamps
Channel With Specialty Perforations
Accessories
Electrical
Designation is indicated by adding type of perforation from standard
selection and pertinent dimensional information. Example: W-200H 1" from
each end. If used as a trapeze reference page 126.
Concrete
Inserts
Beam Loading Of Punched Channels
To obtain the allowable load of punched channel as a beam, multiply the
allowable load by the following:
Cushioned
Clamping
Slotted Channel (SL, SS) 0.90
Channel With Holes (H) 0.95
X
Knock-Out Channel (KO) 0.95
Supports
Rooftop
Load and Deflection Development
(typical to each channel section)
Specifications
Material
Loads calculated in accordance with the AISI Cold-Formed Steel Design Manual, 2013 Edition.
Utilizing the PROPERTIES OF SECTION, ALLOWABLE COLUMN LOADS 4. To obtain allowable concentrated load based on 25,000 PSI stresses,
and ALLOWABLE BEAM LOAD charts shown for each individual Channel divide figures shown in upper lines by 2.
Section, additional load and deflection data may be developed with the 5. Column loads are the allowable total axial load applied at the centroid of
Information
following information:
Design
the section. Loads applied at the face of the column must be reduced for
1. All figures show TOTAL LOAD in Lbs. the resulting eccentricity as required by standard engineering practice.
2. Figures shown in upper lines give the total uniform load carrying capacity 6. Allowable column loads shown are based upon an effective length factor
of a channel about its X-axis, based on 25,000 PSI stresses, unless noted K = 0.80. For other effective length conditions, the allowable axial load must
Installation
otherwise. This is maximum allowable load. be modified as required by standard engineering practice.
3. Figures shown in lower lines give the total uniform load which will 7. Nominal thickness of 12 gage steel is .105 Inches, 14 gage steel is .075
produce deflection of 1/240 of the span. Inches, 16 gage steel is .060 Inches, and 19 gage steel is .040 Inches,
1 5 8" 1 5 8"
3 7
3
8" 7
8" 8" 8"
Y Y
2 7 16 "
X X
1 .12"
X 4 7 8"
X
Y
Properties of Section
Area of
Channel Wt./Ft. X-X Axis Y-Y Axis
Section
Part No. Lbs.
Sq. in. lx in.4 Sx in.3 rx. in. ly in.4 Sy in.3 ry in.
W-100 2.49 0.732" 0.530" 0.400" 0.851" 0.337" 0.415" 0.679"
W-101 4.98 1.463" 2.867" 1.176" 1.400" 0.674" 0.829" 0.679"
12 www.wesanco.com
W-100 & W-101 S trut
12 G auge - 1 5 8 " x 2 7 16 "
Channel
Channel Nuts
& Hardware
Allowable Beam Loads
W-100 W-101
Fittings
Max. Deflection Uniform Load at Deflection Max. Deflection Uniform Load at Deflection
Span Uniform at Load Span Uniform at Load
Span/180 Span/240 Span/360 Span/180 Span/240 Span/360
Load (W) (W) Load (W) (W)
Brackets
In Lbs In Lbs Lbs Lbs In Lbs In Lbs Lbs Lbs
12 6,700 0.01 6,700 6,700 6,700 12 3,710 * 0.00 3,710 * 3,710 * 3,710 *
18 4,470 0.02 4,470 4,470 4,470 18 3,710 * 0.00 3,710 * 3,710 * 3,710 *
24 3,350 0.04 3,350 3,350 3,350 24 3,710 * 0.01 3,710 * 3,710 * 3,710 *
Clamps
Beam
30 2,680 0.06 2,680 2,680 2,680 30 3,710 * 0.02 3,710 * 3,710 * 3,710 *
36 2,230 0.09 2,230 2,230 2,230 36 3,710 * 0.03 3,710 * 3,710 * 3,710 *
Bases
42 1,910 0.12 1,910 1,910 1,890 42 3,710 * 0.04 3,710 * 3,710 * 3,710 *
Post
48 1,670 0.15 1,670 1,670 1,450 48 3,710 * 0.06 3,710 * 3,710 * 3,710 *
60 1,340 0.24 1,340 1,340 930 60 3,710 * 0.12 3,710 * 3,710 * 3,710 *
Caps
End
72 1,120 0.35 1,120 960 640 72 3,290 0.19 3,290 3,290 3,290
84 960 0.47 940 710 470 84 2,820 0.26 2,820 2,820 2,560
Clamps
96 840 0.62 720 540 360 96 2,470 0.34 2,470 2,470 1,960
108 740 0.78 570 430 290 108 2,190 0.42 2,190 2,190 1,550
120 670 0.96 460 350 230 120 1,970 0.52 1,970 1,880 1,250
Accessories
Electrical
* = Load Limited by Weld Shear
Concrete
Inserts
Allowable Column Loads
W-100 W-101
Cushioned
Clamping
Unbraced Max. Slot Max. Column Load Applied at C.G. Unbraced Max. Slot Max. Column Load Applied at C.G.
Height Face Load K = 0.65 K = 0.80 K = 1.0 K = 1.2 Height Face Load K = 0.65 K = 0.80 K = 1.0 K = 1.2
In Lbs Lbs Lbs Lbs Lbs
Supports
In Lbs Lbs Lbs Lbs Lbs
Rooftop
12 5,090 16,190 15,760 15,090 14,330 12 8,890 33,570 33,290 32,840 32,320
18 4,930 15,180 14,330 13,080 11,770 18 8,820 32,910 32,320 31,420 30,420
24 4,720 13,920 12,640 10,890 9,220 24 8,730 32,030 31,100 29,720 28,280
Specifications
30 8,620 31,010 29,720 27,920 26,150 Material
30 4,430 12,530 10,890 8,830 7,040
36 4,020 11,110 9,220 7,040 5,370 36 8,490 29,900 28,280 26,150 24,190
42 3,610 9,730 7,720 5,600 4,330 42 8,360 28,730 26,840 24,500 22,480
48 3,210 8,440 6,400 4,630 3,640 48 8,220 27,560 25,470 23,020 21,020
Information
60 2,570 6,250 4,630 3,460 2,780 60 7,840 25,310 23,020 20,590 17,300
Design
72 2,130 4,790 3,640 2,780 2,270 72 7,370 23,300 21,020 17,300 12,800
84 1,810 3,900 3,010 2,340 1,920 84 6,870 21,600 18,880 13,530 9,410
96 1,580 3,290 2,590 2,020 1,660 96 6,210 20,180 15,750 10,370 7,200
Installation
108 1,400 2,860 2,270 1,780 1,450 108 5,510 17,890 12,800 8,190 5,690
120 1,270 2,540 2,020 1,580 ** 120 4,850 15,370 10,370 6,640 **
** = KL/r >200 ** = KL/r >200
Index
Y Y
3 1 4"
X X
1 .51"
X X 6 1 2"
Y
Properties of Section
Area of
Channel Wt./Ft. X-X Axis Y-Y Axis
Section
Part No. Lbs.
Sq. in. lx in.4 Sx in.3 rx. in. ly in.4 Sy in.3 ry in.
W-150 3.07 0.902 1.113 0.639 1.111 0.435 0.536 0.695
W-151 6.14 1.804 6.339 1.951 1.874 0.871 1.072 0.695
14 www.wesanco.com
W-150 & W-151 S trut
12 G auge - 1 5 8 " x 3 1 4 "
Channel
Channel Nuts
& Hardware
Allowable Beam Loads
W-150 W-151
Fittings
Max. Deflection Uniform Load at Deflection Max. Deflection Uniform Load at Deflection
Span Uniform at Load Span Uniform at Load
Span/180 Span/240 Span/360 Span/180 Span/240 Span/360
Load (W) (W) Load (W) (W)
Brackets
In Lbs In Lbs Lbs Lbs In Lbs In Lbs Lbs Lbs
12 10,720 0.01 10,720 10,720 10,720 12 4,890 * 0.00 4,890 * 4,890 * 4,890 *
18 7,150 0.02 7,150 7,150 7,150 18 4,890 * 0.00 4,890 * 4,890 * 4,890 *
Clamps
24 5,360 0.03 5,360 5,360 5,360 24 4,890 * 0.00 4,890 * 4,890 * 4,890 *
Beam
30 4,290 0.05 4,290 4,290 4,290 30 4,890 * 0.01 4,890 * 4,890 * 4,890 *
36 3,570 0.07 3,570 3,570 3,570 36 4,890 * 0.02 4,890 * 4,890 * 4,890 *
Bases
Post
42 3,060 0.09 3,060 3,060 3,060 42 4,890 * 0.03 4,890 * 4,890 * 4,890 *
48 2,680 0.12 2,680 2,680 2,680 48 4,890 * 0.04 4,890 * 4,890 * 4,890 *
60 2,140 0.18 2,140 2,140 1,940 60 4,890 * 0.07 4,890 * 4,890 * 4,890 *
Caps
End
72 1,790 0.27 1,790 1,790 1,350 72 4,890 * 0.13 4,890 * 4,890 * 4,890 *
84 1,530 0.36 1,530 1,490 990 84 4,670 0.19 4,670 4,670 4,670
Clamps
96 1,340 0.47 1,340 1,140 760 96 4,090 0.25 4,090 4,090 4,090
108 1,190 0.59 1,190 900 600 108 3,630 0.32 3,630 3,630 3,420
120 1,070 0.73 970 730 490 120 3,270 0.39 3,270 3,270 2,770
Accessories
Electrical
* = Load Limited by Weld Shear
Concrete
Inserts
Allowable Column Loads
W-150 W-151
Cushioned
Clamping
Unbraced Max. Slot Max. Column Load Applied at C.G. Unbraced Max. Slot Max. Column Load Applied at C.G.
Height Face Load K = 0.65 K = 0.80 K = 1.0 K = 1.2 Height Face Load K = 0.65 K = 0.80 K = 1.0 K = 1.2
Supports
In Lbs Lbs Lbs Lbs Lbs In Lbs Lbs Lbs Lbs Lbs
Rooftop
12 6,230 19,910 19,360 18,480 17,490 12 11,040 41,400 41,060 40,490 39,830
18 6,020 18,600 17,490 15,830 14,070 18 10,950 40,570 39,830 38,670 37,350
24 5,730 16,950 15,250 12,890 10,630 24 10,820 39,460 38,240 36,400 34,410
Specifications
Material
30 5,310 15,100 12,890 10,090 7,650 30 10,670 38,130 36,400 33,900 31,330
36 4,740 13,190 10,630 7,650 5,660 36 10,490 36,640 34,410 31,330 28,370
42 4,150 11,320 8,580 5,920 4,450 42 10,290 35,040 32,360 28,850 25,650
48 3,590 9,570 6,870 4,800 3,660 48 10,080 33,380 30,320 26,520 23,250
Information
60 2,740 6,690 4,800 3,460 2,710 60 9,400 30,070 26,520 22,520 19,410
Design
72 2,160 4,990 3,660 2,710 2,170 72 8,650 26,970 23,250 19,410 16,540
84 1,760 3,960 2,970 2,250 1,830 84 7,930 24,210 20,560 17,050 12,160
96 1,500 3,280 2,500 1,930 1,580 96 7,280 21,830 18,390 13,400 9,310
Installation
108 1,310 2,800 2,170 1,700 1,400 108 6,660 19,820 16,540 10,590 7,350
120 1,170 2,460 1,930 1,520 ** 120 5,800 18,150 13,400 8,580 **
** = KL/r >200 ** = KL/r >200
Index
1 5 8"
X X
0 .718"
1
X X 3 4"
Y
Properties of Section
Area of
Channel Wt./Ft. X-X Axis Y-Y Axis
Section
Part No. Lbs.
Sq. in. lx in.4 Sx in.3 rx. in. ly in.4 Sy in.3 ry in.
W-200 1.91 0.561 0.188 0.207 0.579 0.238 0.293 0.652
W-201 3.82 1.122 0.954 0.587 0.922 0.477 0.587 0.652
16 www.wesanco.com
W-200 & W-201 S trut
12 G auge - 1 5 8 " x 1 5 8 "
Channel
Channel Nuts
& Hardware
Allowable Beam Loads
W-200 W-201
Fittings
Max. Deflection Uniform Load at Deflection Max. Deflection Uniform Load at Deflection
Span Uniform at Load Span Uniform at Load
Span/180 Span/240 Span/360 Span/180 Span/240 Span/360
Load (W) (W) Load (W) (W)
Brackets
In Lbs In Lbs Lbs Lbs In Lbs In Lbs Lbs Lbs
12 3,480 0.01 3,480 3,480 3,480 12 2,500 * 0.00 2,500 * 2,500 * 2,500 *
18 2,320 0.03 2,320 2,320 2,320 18 2,500 * 0.01 2,500 * 2,500 * 2,500 *
24 1,740 0.06 1,740 1,740 1,740 24 2,500 * 0.02 2,500 * 2,500 * 2,500 *
Clamps
Beam
30 1,390 0.09 1,390 1,390 1,310 30 2,500 * 0.03 2,500 * 2,500 * 2,500 *
36 1,160 0.13 1,160 1,160 910 36 2,500 * 0.05 2,500 * 2,500 * 2,500 *
Bases
42 990 0.17 990 990 670 42 2,500 * 0.09 2,500 * 2,500 * 2,500 *
Post
48 870 0.23 870 770 510 48 2,460 0.13 2,460 2,460 2,460
60 700 0.35 660 490 330 60 1,970 0.20 1,970 1,970 1,670
Caps
End
72 580 0.51 460 340 230 72 1,640 0.28 1,640 1,640 1,160
84 500 0.70 340 250 170 84 1,410 0.39 1,410 1,280 850
Clamps
96 430 0.89 260 190 130 96 1,230 0.50 1,230 980 650
108 390 1.15 200 150 100 108 1,090 0.64 1,030 770 510
120 350 1.42 160 120 80 120 980 0.78 830 630 420
Accessories
Electrical
* = Load Limited by Weld Shear
Concrete
Inserts
Allowable Column Loads
W-200 W-201
Cushioned
Clamping
Unbraced Max. Slot Max. Column Load Applied at C.G. Unbraced Max. Slot Max. Column Load Applied at C.G.
Height Face Load K = 0.65 K = 0.80 K = 1.0 K = 1.2 Height Face Load K = 0.65 K = 0.80 K = 1.0 K = 1.2
Supports
Rooftop
In Lbs Lbs Lbs Lbs Lbs In Lbs Lbs Lbs Lbs Lbs
12 3,870 12,430 12,120 11,640 11,110 12 6,700 25,700 25,480 25,120 24,720
18 3,760 11,710 11,110 10,260 9,400 18 6,650 25,170 24,720 24,060 23,360
Specifications
24 3,620 10,830 9,970 8,830 7,780 24 6,580 24,510 23,830 22,900 22,010
Material
30 3,460 9,900 8,830 7,540 6,420 30 6,510 23,770 22,900 21,790 20,810
36 3,250 8,970 7,780 6,420 5,330 36 6,430 23,020 22,010 20,810 19,820
42 3,020 8,100 6,840 5,490 4,450 42 6,360 22,280 21,180 19,970 18,230
48 2,800 7,300 6,030 4,710 3,820 48 6,290 21,580 20,450 18,860 16,320
Information
60 2,410 5,940 4,710 3,650 2,970 60 6,130 20,370 18,860 15,680 12,520
Design
72 2,110 4,850 3,820 2,970 2,410 72 5,730 19,160 16,320 12,520 9,040
84 1,870 4,060 3,210 2,490 1,990 84 5,270 17,120 13,760 9,570 6,640
96 1,680 3,490 2,760 2,120 1,670 96 4,770 15,040 11,310 7,320 5,090
Installation
108 1,530 3,060 2,410 1,830 ** 108 4,240 12,980 9,040 5,790 4,020
120 1,390 2,710 2,120 ** ** 120 3,750 11,010 7,320 4,690 **
** = KL/r >200 ** = KL/r >200
Index
1 5 8" 1 5 8"
3 3
8" 7
8" 8" 7
8"
Y Y
1 5 8"
X X
0 .729"
X X 3 1 4"
Y
Properties of Section
Area of
Channel Wt./Ft. X-X Axis Y-Y Axis
Section
Part No. Lbs.
Sq. in. lx in.4 Sx in.3 rx. in. ly in.4 Sy in.3 ry in.
W-210 1.42 0.417 0.148 0.169 0.596 0.183 0.225 0.662
W-211 2.84 0.834 0.739 0.455 0.942 0.365 0.450 0.662
18 www.wesanco.com
W-210 & W-211 S trut
14 G auge - 1 5 8 " x 1 5 8 "
Channel
Channel Nuts
& Hardware
Allowable Beam Loads
W-210 W-211
Fittings
Max. Deflection Uniform Load at Deflection Max. Deflection Uniform Load at Deflection
Span Uniform at Load Span Uniform at Load
Span/180 Span/240 Span/360 Span/180 Span/240 Span/360
Load (W) (W) Load (W) (W)
Brackets
In Lbs In Lbs Lbs Lbs In Lbs In Lbs Lbs Lbs
12 2,840 0.01 2,840 2,840 2,840 12 1,600 * 0.00 1,600 * 1,600 * 1,600 *
18 1,890 0.03 1,890 1,890 1,890 18 1,600 * 0.01 1,600 * 1,600 * 1,600 *
24 1,420 0.06 1,420 1,420 1,420
Clamps
24 1,600 * 0.01 1,600 * 1,600 * 1,600 *
Beam
30 1,130 0.09 1,130 1,130 1,030 30 1,600 * 0.03 1,600 * 1,600 * 1,600 *
36 950 0.13 950 950 720 36 1,600 * 0.04 1,600 * 1,600 * 1,600 *
Bases
42 810 0.18 810 790 530 42 1,600 * 0.07 1,600 * 1,600 * 1,600 *
Post
48 710 0.23 710 610 400 48 1,600 * 0.11 1,600 * 1,600 * 1,600 *
60 570 0.37 520 390 260 60 1,530 0.20 1,530 1,530 1,290
Caps
End
72 470 0.52 360 270 180 72 1,270 0.28 1,270 1,270 900
84 410 0.72 260 200 130 84 1,090 0.39 1,090 990 660
Clamps
96 350 0.92 200 150 100 96 950 0.50 950 760 500
108 320 1.20 160 120 80 108 850 0.64 800 600 400
120 280 1.44 130 100 60 120 760 0.78 650 480 320
Accessories
Electrical
* = Load Limited by Weld Shear
Concrete
Inserts
Allowable Column Loads
W-210 W-211
Cushioned
Clamping
Unbraced Max. Slot Max. Column Load Applied at C.G. Unbraced Max. Slot Max. Column Load Applied at C.G.
Height Face Load K = 0.65 K = 0.80 K = 1.0 K = 1.2 Height Face Load K = 0.65 K = 0.80 K = 1.0 K = 1.2
Supports
Rooftop
In Lbs Lbs Lbs Lbs Lbs In Lbs Lbs Lbs Lbs Lbs
12 3,110 9,250 9,020 8,660 8,250 12 5,140 19,130 18,970 18,700 18,390
18 3,010 8,710 8,250 7,560 6,840 18 5,090 18,740 18,390 17,860 17,280
Specifications
24 2,880 8,030 7,330 6,360 5,420 24 5,040 18,230 17,670 16,860 16,010
Material
30 2,710 7,270 6,360 5,200 4,190 30 4,970 17,630 16,860 15,800 14,760
36 2,460 6,480 5,420 4,190 3,210 36 4,890 16,970 16,010 14,760 13,610
42 2,210 5,710 4,570 3,340 2,580 42 4,810 16,280 15,170 13,790 12,600
48 1,980 4,990 3,830 2,760 2,160 48 4,720 15,590 14,360 12,920 11,740
Information
60 1,570 3,740 2,760 2,050 1,640 60 4,500 14,260 12,920 11,480 9,280
Design
72 1,300 2,860 2,160 1,640 1,320 72 4,230 13,080 11,740 9,280 6,690
84 1,100 2,310 1,780 1,370 1,110 84 3,890 12,080 10,210 7,080 4,920
96 950 1,950 1,520 1,170 950 96 3,490 11,150 8,380 5,420 3,770
Installation
108 840 1,690 1,320 1,030 ** 108 3,060 9,620 6,690 4,280 2,980
120 750 1,490 1,170 ** ** 120 2,690 8,160 5,420 3,470 **
** = KL/r >200 ** = KL/r >200
Index
1 3 8"
X X
X X 2 3 4"
0 .579"
Y
Properties of Section
Area of
Channel Wt./Ft. X-X Axis Y-Y Axis
Section
Part No. Lbs.
Sq. in. lx in.4 Sx in.3 rx. in. ly in.4 Sy in.3 ry in.
W-300 1.73 0.508 0.123 0.158 0.491 0.208 0.256 0.640
W-301 3.46 1.017 0.608 0.443 0.774 0.416 0.512 0.640
20 www.wesanco.com
W-300 & W-301 S trut
12 G auge - 1 5 8 " x 1 3 8 "
Channel
Channel Nuts
& Hardware
Allowable Beam Loads
W-300 W-301
Fittings
Max. Deflection Uniform Load at Deflection Max. Deflection Uniform Load at Deflection
Span Uniform at Load Span Uniform at Load
Span/180 Span/240 Span/360 Span/180 Span/240 Span/360
Load (W) (W) Load (W) (W)
Brackets
In Lbs In Lbs Lbs Lbs In Lbs In Lbs Lbs Lbs
12 2,650 0.02 2,650 2,650 2,650 12 2,110 * 0.00 2,110 * 2,110 * 2,110 *
18 1,770 0.04 1,770 1,770 1,770 18 2,110 * 0.01 2,110 * 2,110 * 2,110 *
24 1,320 0.07 1,320 1,320 1,320 24 2,110 * 0.02 2,110 * 2,110 * 2,110 *
Clamps
Beam
30 1,060 0.10 1,060 1,060 860 30 2,110 * 0.04 2,110 * 2,110 * 2,110 *
36 880 0.15 880 880 600 36 2,110 * 0.07 2,110 * 2,110 * 2,110 *
Bases
42 760 0.20 760 660 440 42 2,110 * 0.11 2,110 * 2,110 * 2,110 *
Post
48 660 0.26 660 500 340 48 1,860 0.15 1,860 1,860 1,660
60 530 0.41 430 320 210 60 1,490 0.23 1,490 1,490 1,060
Caps
End
72 440 0.59 300 220 150 72 1,240 0.34 1,240 1,110 740
84 380 0.81 220 160 110 84 1,060 0.46 1,060 810 540
Clamps
96 330 1.05 170 130 80 96 930 0.60 830 620 410
108 290 1.31 130 100 70 108 830 0.76 660 490 330
120 260 1.62 110 80 50 120 740 0.93 530 400 270
Accessories
Electrical
* = Load Limited by Weld Shear
Concrete
Inserts
Allowable Column Loads
W-300 W-301
Cushioned
Clamping
Unbraced Max. Slot Max. Column Load Applied at C.G. Unbraced Max. Slot Max. Column Load Applied at C.G.
Height Face Load K = 0.65 K = 0.80 K = 1.0 K = 1.2 Height Face Load K = 0.65 K = 0.80 K = 1.0 K = 1.2
Supports
Rooftop
In Lbs Lbs Lbs Lbs Lbs In Lbs Lbs Lbs Lbs Lbs
12 3,480 11,260 10,980 10,550 10,080 12 6,000 23,260 23,040 22,700 22,330
18 3,380 10,600 10,080 9,340 8,610 18 5,950 22,750 22,330 21,730 21,120
Specifications
24 3,260 9,830 9,100 8,150 7,280 24 5,890 22,130 21,520 20,730 20,000
Material
30 3,130 9,030 8,150 7,080 6,180 30 5,830 21,470 20,730 19,830 19,080
36 2,980 8,260 7,280 6,180 5,280 36 5,770 20,830 20,000 19,080 17,990
42 2,800 7,540 6,520 5,420 4,510 42 5,720 20,220 19,360 18,260 16,270
48 2,640 6,890 5,860 4,760 3,890 48 5,670 19,670 18,820 16,850 14,500
Information
60 2,340 5,780 4,760 3,720 3,010 60 5,470 18,750 16,850 13,900 10,990
Design
72 2,080 4,880 3,890 3,010 2,330 72 5,150 17,140 14,500 10,990 7,860
84 1,860 4,130 3,270 2,470 ** 84 4,740 15,240 12,140 8,320 5,770
96 1,680 3,550 2,790 1,890 ** 96 4,280 13,310 9,890 6,370 4,420
Installation
1 5 8" 1 5 8"
3 7
3
8" 7
8" 8" 8"
Y Y
13
X X 16 "
X X 1 5 8"
0 .347"
Y
Properties of Section
Area of
Channel Wt./Ft. X-X Axis Y-Y Axis
Section
Part No. Lbs.
Sq. in. lx in.4 Sx in.3 rx. in. ly in.4 Sy in.3 ry in.
W-400 0.83 0.244 0.023 0.050 0.310 0.092 0.113 0.614
W-401 1.66 0.487 0.105 0.129 0.463 0.184 0.226 0.614
22 www.wesanco.com
W-400 & W-401 S trut
16 G auge - 1 5 8 " x 13 16 "
Channel
Channel Nuts
& Hardware
Allowable Beam Loads
W-400 W-401
Fittings
Max. Deflection Uniform Load at Deflection Max. Deflection Uniform Load at Deflection
Span Uniform at Load Span Uniform at Load
Span/180 Span/240 Span/360 Span/180 Span/240 Span/360
Load (W) (W) Load (W) (W)
Brackets
In Lbs In Lbs Lbs Lbs In Lbs In Lbs Lbs Lbs
12 840 0.03 840 840 840 12 500 * 0.00 500 * 500 * 500 *
18 560 0.06 560 560 450 18 500 * 0.01 500 * 500 * 500 *
24 420 0.11 420 380 260 24 500 * 0.03 500 * 500 * 500 *
Clamps
Beam
30 330 0.17 330 250 160 30 500 * 0.06 500 * 500 * 500 *
36 280 0.25 230 170 110 36 500 * 0.10 500 * 500 * 500 *
Bases
42 240 0.34 170 130 80 42 500 * 0.16 500 * 500 * 370
Post
48 210 0.44 130 100 60 48 500 * 0.23 500 * 430 290
60 170 0.69 80 60 40 60 430 0.39 370 270 180
Caps
End
72 140 0.99 60 40 30 72 360 0.57 250 190 130
84 120 1.34 40 30 20 84 310 0.78 190 140 90
Clamps
96 100 1.67 30 20 20 96 270 1.01 140 110 70
108 90 2.14 30 20 10 108 240 1.28 110 80 60
120 80 2.61 20 20 10 120 220 1.60 90 70 50
Accessories
Electrical
* = Load Limited by Weld Shear
Concrete
Inserts
Allowable Column Loads
W-400 W-401
Cushioned
Clamping
Unbraced Max. Slot Max. Column Load Applied at C.G. Unbraced Max. Slot Max. Column Load Applied at C.G.
Height Face Load K = 0.65 K = 0.80 K = 1.0 K = 1.2 Height Face Load K = 0.65 K = 0.80 K = 1.0 K = 1.2
Supports
Rooftop
In Lbs Lbs Lbs Lbs Lbs In Lbs Lbs Lbs Lbs Lbs
12 1,780 5,390 5,250 5,040 4,800 12 2,920 11,090 10,960 10,750 10,520
18 1,720 5,070 4,800 4,420 4,030 18 2,890 10,780 10,520 10,140 9,740
Specifications
24 1,650 4,680 4,290 3,780 3,310 24 2,850 10,390 10,000 9,470 8,960
Material
30 1,570 4,260 3,780 3,210 2,520 30 2,800 9,970 9,470 8,810 7,870
36 1,470 3,840 3,310 2,520 1,780 36 2,760 9,540 8,960 7,870 6,700
42 1,340 3,460 2,800 1,880 1,310 42 2,690 9,120 8,260 6,900 5,530
48 1,180 3,080 2,250 1,440 1,000 48 2,600 8,630 7,490 5,920 4,440
Information
1 5 8" 1 5 8"
3 7 3 7
8" 8" 8" 8"
Y Y
13
X X 16 "
X X 1 5 8"
0 .342"
Y
Properties of Section
Area of
Channel Wt./Ft. X-X Axis Y-Y Axis
Section
Part No. Lbs.
Sq. in. lx in.4 Sx in.3 rx. in. ly in.4 Sy in.3 ry in.
W-500 1.00 0.295 0.026 0.056 0.297 0.109 0.135 0.609
W-501 2.01 0.590 0.122 0.150 0.454 0.219 0.269 0.609
24 www.wesanco.com
W-500 & W-501 S trut
14 G auge - 1 5 8 " x 13 16 "
Channel
Channel Nuts
& Hardware
Allowable Beam Loads
W-500 W-501
Fittings
Max. Deflection Uniform Load at Deflection Max. Deflection Uniform Load at Deflection
Span Uniform at Load Span Uniform at Load
Span/180 Span/240 Span/360 Span/180 Span/240 Span/360
Load (W) (W) Load (W) (W)
Brackets
In Lbs In Lbs Lbs Lbs In Lbs In Lbs Lbs Lbs
12 930 0.03 930 930 930 12 790 * 0.00 790 * 790 * 790 *
18 620 0.06 620 620 510 18 790 * 0.02 790 * 790 * 790 *
Clamps
24 470 0.11 470 430 290 24 790 * 0.04 790 * 790 * 790 *
Beam
30 370 0.17 370 270 180 30 790 * 0.08 790 * 790 * 790 *
36 310 0.24 250 190 130 36 790 * 0.13 790 * 790 * 590
Bases
42 270 0.34 190 140 90
Post
42 720 0.19 720 650 430
48 230 0.43 140 110 70 48 630 0.25 630 500 330
60 190 0.69 90 70 50 60 500 0.39 420 320 210
Caps
End
72 160 1.01 60 50 30 72 420 0.57 300 220 150
84 130 1.30 50 40 20 84 360 0.78 220 160 110
Clamps
96 120 1.79 40 30 20 96 310 1.00 170 120 80
108 100 2.12 30 20 10 108 280 1.28 130 100 70
120 90 2.62 20 20 10 120 250 1.57 110 80 50
Accessories
Electrical
* = Load Limited by Weld Shear
Concrete
Inserts
Allowable Column Loads
W-500 W-501
Cushioned
Clamping
Unbraced Max. Slot Max. Column Load Applied at C.G. Unbraced Max. Slot Max. Column Load Applied at C.G.
Height Face Load K = 0.65 K = 0.80 K = 1.0 K = 1.2 Height Face Load K = 0.65 K = 0.80 K = 1.0 K = 1.2
Supports
In Lbs Lbs Lbs Lbs Lbs In Lbs Lbs Lbs Lbs Lbs
Rooftop
12 2,010 6,530 6,360 6,110 5,840 12 3,430 13,420 13,250 13,000 12,720
18 1,950 6,140 5,840 5,420 5,010 18 3,390 13,030 12,720 12,300 11,880
Specifications
24 1,890 5,700 5,280 4,650 3,910 24 3,350 12,580 12,160 11,590 10,740
Material
30 1,800 5,250 4,650 3,720 2,840 30 3,310 12,120 11,590 10,520 9,340
36 1,680 4,740 3,910 2,840 1,980 36 3,230 11,680 10,740 9,340 7,870
42 1,510 4,140 3,180 2,100 1,460 42 3,150 11,010 9,820 8,110 6,430
48 1,330 3,540 2,510 1,610 1,110 48 3,040 10,290 8,850 6,900 5,080
Information
13 13
16 " 16 "
7 7
3 16 " 3 16 "
16 " 16 "
Y Y
13
X X 16 "
X X 1 5 8"
0 .352"
Y
Properties of Section
Area of
Channel Wt./Ft. X-X Axis Y-Y Axis
Section
Part No. Lbs.
Sq. in. lx in.4 Sx in.3 rx. in. ly in.4 Sy in.3 ry in.
W-600 0.36 0.107 0.009 0.020 0.295 0.012 0.029 0.333
W-601 0.73 0.214 0.045 0.056 0.459 0.024 0.058 0.333
26 www.wesanco.com
W-600 & W-601 S trut
19 G auge - 13 16 " x 13 16 "
Channel
Channel Nuts
& Hardware
Allowable Beam Loads
W-600 W-601
Fittings
Max. Deflection Uniform Load at Deflection Max. Deflection Uniform Load at Deflection
Span Uniform at Load Span Uniform at Load
Span/180 Span/240 Span/360 Span/180 Span/240 Span/360
Load (W) (W) Load (W) (W)
Brackets
In Lbs In Lbs Lbs Lbs In Lbs In Lbs Lbs Lbs
12 340 0.03 340 340 340 12 280 * 0.00 280 * 280 * 280 *
18 230 0.06 230 230 180 18 280 * 0.02 280 * 280 * 280 *
24 170 0.11 170 150 100
Clamps
24 280 * 0.04 280 * 280 * 280 *
Beam
30 140 0.18 130 100 70 30 280 * 0.07 280 * 280 * 280 *
36 110 0.24 90 70 50 36 280 * 0.13 280 * 280 * 220
Bases
42 100 0.35 70 50 30 42 270 0.20 270 240 160
Post
48 80 0.42 50 40 30 48 230 0.25 230 180 120
60 70 0.72 30 20 20 60 190 0.40 160 120 80
Caps
End
72 60 1.06 20 20 10 72 160 0.58 110 80 50
84 50 1.41 20 10 10 84 130 0.75 80 60 40
Clamps
96 40 1.68 10 10 10 96 120 1.04 60 50 30
108 40 2.39 10 10 10 108 100 1.23 50 40 20
120 30 2.46 10 10 NR 120 90 1.52 40 30 20
Accessories
Electrical
* = Load Limited by Weld Shear
Concrete
Inserts
Allowable Column Loads
W-600 W-601
Cushioned
Clamping
Unbraced Max. Slot Max. Column Load Applied at C.G. Unbraced Max. Slot Max. Column Load Applied at C.G.
Height Face Load K = 0.65 K = 0.80 K = 1.0 K = 1.2 Height Face Load K = 0.65 K = 0.80 K = 1.0 K = 1.2
Supports
In Lbs Lbs Lbs Lbs Lbs In Lbs Lbs Lbs Lbs Lbs
Rooftop
12 700 2,050 1,880 1,630 1,400 12 1,240 4,650 4,510 4,300 4,090
18 600 1,660 1,400 1,100 860 18 1,210 4,330 4,090 3,780 3,500
Specifications
24 490 1,300 1,010 740 590 24 1,170 3,980 3,680 3,340 3,060
Material
30 400 990 740 560 450 30 1,130 3,660 3,340 3,010 2,460
36 340 770 590 450 370 36 1,070 3,380 3,060 2,460 1,800
42 290 630 490 380 310 42 990 3,140 2,690 1,900 1,320
48 260 540 420 330 270 48 900 2,930 2,230 1,460 1,010
Information
108 ** ** ** ** ** 108 ** ** ** ** **
120 ** ** ** ** ** 120 ** ** ** ** **
** = KL/r >200 ** = KL/r >200
Index
13 13
16 " 16 "
7 7
3 16 " 3 16 "
16 " 16 "
Y
Y
13
X X 32 "
X 13
X 16 "
Y 0 .165" Y
Properties of Section
Area of
Channel Wt./Ft. X-X Axis Y-Y Axis
Section
Part No. Lbs.
Sq. in. lx in.4 Sx in.3 rx. in. ly in.4 Sy in.3 ry in.
W-700 0.25 0.074 0.002 0.007 0.149 0.007 0.017 0.307
W-701 0.51 0.149 0.007 0.018 0.222 0.014 0.034 0.307
28 www.wesanco.com
W-700 & W-701 S trut
19 G auge - 13 16 " x 13 32 "
Channel
Channel Nuts
& Hardware
Allowable Beam Loads
W-700 W-701
Fittings
Max. Deflection Uniform Load at Deflection Max. Deflection Uniform Load at Deflection
Span Uniform at Load Span Uniform at Load
Span/180 Span/240 Span/360 Span/180 Span/240 Span/360
Load (W) (W) Load (W) (W)
Brackets
In Lbs In Lbs Lbs Lbs In Lbs In Lbs Lbs Lbs
12 110 0.05 110 110 70 12 140 * 0.01 140 * 140 * 140 *
18 80 0.12 70 50 30 18 140 * 0.05 140 * 140 * 140 *
Clamps
24 60 0.22 40 30 20 24 140 * 0.12 140 * 120 80
Beam
30 50 0.35 20 20 10 30 120 0.20 100 80 50
36 40 0.48 20 10 10 36 100 0.28 70 50 40
Bases
42 30 0.58 10 10 10
Post
42 90 0.40 50 40 30
48 30 0.86 10 10 NR 48 80 0.53 40 30 20
60 20 1.12 10 NR NR 60 60 0.78 30 20 10
Caps
End
72 20 1.94 NR NR NR 72 50 1.13 20 10 10
84 20 3.08 NR NR NR 84 40 1.43 10 10 10
Clamps
96 10 2.30 NR NR NR 96 40 2.14 10 10 NR
108 10 3.27 NR NR NR 108 30 2.29 10 10 NR
120 10 4.49 NR NR NR 120 30 3.13 10 NR NR
Accessories
Electrical
* = Load Limited by Weld Shear
Concrete
Inserts
Allowable Column Loads
W-700 W-701
Cushioned
Clamping
Unbraced Max. Slot Max. Column Load Applied at C.G. Unbraced Max. Slot Max. Column Load Applied at C.G.
Height Face Load K = 0.65 K = 0.80 K = 1.0 K = 1.2 Height Face Load K = 0.65 K = 0.80 K = 1.0 K = 1.2
Supports
Rooftop
In Lbs Lbs Lbs Lbs Lbs In Lbs Lbs Lbs Lbs Lbs
12 460 1,430 1,330 1,170 990 12 820 3,150 3,040 2,910 2,690
18 410 1,190 990 720 500 18 790 2,930 2,690 2,330 1,960
Specifications
24 330 890 630 410 280 24 740 2,570 2,210 1,710 1,250
Material
30 260 620 410 ** ** 30 670 2,180 1,710 1,150 800
36 200 430 280 ** ** 36 580 1,770 1,250 800 560
42 ** 310 ** ** ** 42 490 1,390 920 590 **
48 ** ** ** ** ** 48 420 1,070 700 ** **
Information
60 ** ** ** ** ** 60 ** 680 ** ** **
Design
72 ** ** ** ** ** 72 ** ** ** ** **
84 ** ** ** ** ** 84 ** ** ** ** **
96 ** ** ** ** ** 96 ** ** ** ** **
Installation
108 ** ** ** ** ** 108 ** ** ** ** **
120 ** ** ** ** ** 120 ** ** ** ** **
** = KL/r >200 ** = KL/r >200
Index
1 5 8" 1 5 8"
3 7 3 7
8" 8" 8" 8"
Y Y
1"
X X
X X 2"
0 .422"
Y
Properties of Section
Area of
Channel Wt./Ft. X-X Axis Y-Y Axis
Section
Part No. Lbs.
Sq. in. lx in.4 Sx in.3 rx. in. ly in.4 Sy in.3 ry in.
W-800 1.46 0.430 0.054 0.093 0.354 0.163 0.200 0.615
W-801 2.92 0.859 0.261 0.261 0.551 0.325 0.400 0.615
30 www.wesanco.com
W-800 & W-801 S trut
12 G auge - 1 5 8 " x 1"
Channel
Channel Nuts
& Hardware
Allowable Beam Loads
W-800 W-801
Fittings
Max. Deflection Uniform Load at Deflection Max. Deflection Uniform Load at Deflection
Span Uniform at Load Span Uniform at Load
Span/180 Span/240 Span/360 Span/180 Span/240 Span/360
Load (W) (W) Load (W) (W)
Brackets
In Lbs In Lbs Lbs Lbs In Lbs In Lbs Lbs Lbs
12 1,560 0.02 1,560 1,560 1,560 12 1,520 * 0.00 1,520 * 1,520 * 1,520 *
18 1,040 0.05 1,040 1,040 1,040 18 1,520 * 0.02 1,520 * 1,520 * 1,520 *
24 780 0.09 780 780 590 24 1,520 * 0.04 1,520 * 1,520 * 1,520 *
Clamps
Beam
30 630 0.14 630 570 380 30 1,520 * 0.07 1,520 * 1,520 * 1,520 *
36 520 0.20 520 390 260 36 1,460 0.12 1,460 1,460 1,270
Bases
42 450 0.27 380 290 190 42 1,250 0.16 1,250 1,250 930
Post
48 390 0.35 290 220 150 48 1,090 0.20 1,090 1,070 710
60 310 0.55 190 140 90 60 870 0.32 870 680 460
Caps
End
72 260 0.79 130 100 70 72 730 0.46 630 470 320
84 220 1.07 100 70 50 84 620 0.62 470 350 230
Clamps
96 200 1.45 70 60 40 96 550 0.82 360 270 180
108 170 1.75 60 40 30 108 490 1.04 280 210 140
120 160 2.26 50 40 20 120 440 1.29 230 170 110
Accessories
Electrical
* = Load Limited by Weld Shear
Concrete
Inserts
Allowable Column Loads
W-800 W-801
Cushioned
Clamping
Unbraced Max. Slot Max. Column Load Applied at C.G. Unbraced Max. Slot Max. Column Load Applied at C.G.
Height Face Load K = 0.65 K = 0.80 K = 1.0 K = 1.2 Height Face Load K = 0.65 K = 0.80 K = 1.0 K = 1.2
Supports
In Lbs Lbs Lbs Lbs Lbs In Lbs Lbs Lbs Lbs Lbs
Rooftop
12 2,220 9,730 9,590 9,350 9,070 12 5,660 19,300 18,950 18,430 17,870
18 2,190 9,390 9,070 8,580 8,010 18 5,560 18,500 17,870 17,000 16,160
24 2,150 8,920 8,400 7,600 6,730 24 5,440 17,580 16,720 15,640 14,720
Specifications
Material
30 2,090 8,350 7,600 6,500 5,370 30 5,320 16,650 15,640 14,510 13,590
36 2,020 7,700 6,730 5,370 4,090 36 5,210 15,770 14,720 13,590 11,460
42 1,930 7,000 5,820 4,290 3,010 42 5,110 14,990 13,940 11,810 9,360
48 1,820 6,280 4,930 3,320 2,310 48 4,920 14,310 12,880 10,050 7,400
Information
Y Y
7
X X 8"
3
X X 1 4"
0 .364"
Y
Properties of Section
Area of
Channel Wt./Ft. X-X Axis Y-Y Axis
Section
Part No. Lbs.
Sq. in. lx in.4 Sx in.3 rx. in. ly in.4 Sy in.3 ry in.
W-900 1.37 0.403 0.038 0.074 0.307 0.147 0.181 0.604
W-901 2.75 0.807 0.183 0.209 0.476 0.295 0.363 0.604
32 www.wesanco.com
W-900 & W-901 S trut
12 G auge - 1 5 8 " x 7 8 "
Channel
Channel Nuts
& Hardware
Allowable Beam Loads
W-900 W-901
Fittings
Max. Deflection Uniform Load at Deflection Max. Deflection Uniform Load at Deflection
Span Uniform at Load Span Uniform at Load
Span/180 Span/240 Span/360 Span/180 Span/240 Span/360
Load (W) (W) Load (W) (W)
Brackets
In Lbs In Lbs Lbs Lbs In Lbs In Lbs Lbs Lbs
12 1,250 0.03 1,250 1,250 1,250 12 1,310 * 0.01 1,310 * 1,310 * 1,310 *
18 830 0.06 830 830 740 18 1,310 * 0.02 1,310 * 1,310 * 1,310 *
24 620 0.10 620 620 420 24 1,310 * 0.04 1,310 * 1,310 * 1,310 *
Clamps
Beam
30 500 0.16 500 400 270 30 1,310 * 0.09 1,310 * 1,310 * 1,280
36 420 0.23 370 280 180 36 1,170 0.13 1,170 1,170 890
Bases
42 360 0.31 270 200 140 42 1,000 0.18 1,000 980 650
Post
48 310 0.40 210 160 100 48 880 0.23 880 750 500
60 250 0.63 130 100 70 60 700 0.37 640 480 320
Caps
End
72 210 0.91 90 70 50 72 580 0.52 440 330 220
84 180 1.24 70 50 30 84 500 0.72 330 240 160
Clamps
96 160 1.64 50 40 30 96 440 0.94 250 190 120
108 140 2.05 40 30 20 108 390 1.19 200 150 100
120 120 2.41 30 20 20 120 350 1.46 160 120 80
Accessories
Electrical
* = Load Limited by Weld Shear
Concrete
Inserts
Allowable Column Loads
W-900 W-901
Cushioned
Clamping
Unbraced Max. Slot Max. Column Load Applied at C.G. Unbraced Max. Slot Max. Column Load Applied at C.G.
Height Face Load K = 0.65 K = 0.80 K = 1.0 K = 1.2 Height Face Load K = 0.65 K = 0.80 K = 1.0 K = 1.2
Supports
Rooftop
In Lbs Lbs Lbs Lbs Lbs In Lbs Lbs Lbs Lbs Lbs
12 2,560 8,900 8,670 8,360 8,040 12 4,510 18,310 18,090 17,780 17,470
18 2,500 8,400 8,040 7,580 6,980 18 4,470 17,820 17,470 17,040 16,590
Specifications
24 2,440 7,880 7,430 6,510 5,530 24 4,430 17,320 16,900 16,110 15,040
Material
30 2,330 7,380 6,510 5,280 4,100 30 4,380 16,870 16,110 14,760 13,260
36 2,190 6,620 5,530 4,100 2,890 36 4,290 16,230 15,040 13,260 11,360
42 2,020 5,840 4,560 3,050 2,120 42 4,190 15,390 13,870 11,680 9,470
48 1,820 5,040 3,650 2,340 1,620 48 4,070 14,460 12,630 10,090 7,670
Information
Design
34 www.wesanco.com
C hannel N uts
Standard Finish: Electro Galvanized
Channel Nut With Long Spring Channel Nut With Short Spring
Channel
Use with W-100 and W-150 Use with W-400,W-500,W-800 and W-900
Channel Nuts
& Hardware
Fittings
Brackets
Channel Wt. Channel Wt.
Size Thread Thickness Size Thread Thickness
Clamps
Beam
Part No. Lbs/C Part No. Lbs/C
1 1 1
W-1-4 4" 20 4" 7.5 W-5-0832 #8 32 4" 7.5
3 3 1
W-1-6 8" 16 8" 10.0 W-5-1032 #10 32 4" 7.5
Bases
Post
1 1 1
W-1-8 2" 13 2" 12.0 W-5-1024 #10 24 4" 7.5
5 7 1 1
W-1-10 8" 11 16" 16.0 W-5-4 4" 20 4" 7.5
Caps
End
3 7 5 3
W-1-12 4" 10 16" 15.5 W-5-5 16" 18 8" 8.7
3 3
W-5-6 8" 16 8" 9.0
Clamps
1 3
W-5-8 2" 13 8" 8.2
5 3
W-5-10 8" 11 8" 14.0
Accessories
Electrical
Channel Nut With Standard Spring Channel Nut Without Spring
Use with W-200, W-210, and W-300 Use with W-100, W-150, W-200, W-210, W-300, W-400,
W-500, W-800, and W-900
Concrete
Inserts
Cushioned
Clamping
Supports
Rooftop
Channel Wt.
Use Size Thread Thickness
Part No. Lbs/C
1
W-2-0832WS #8 32 4" 6.5
Specifications
1
Channel Wt. W-2-1032WS #10 32 4" 6.5 Material
Size Thread Thickness W-2-1024WS #10 24 1
4" 6.5
Part No. Lbs/C
1 1
W-2-0832 #8 32 1
4" 7.5 W-2-4WS 4" 20 4" 6.5
5 3
W-2-1032 #10 32 1
4" 7.5 W-2-5WS 16" 18 8" 8.7
3 3
1 W-2-6WS 8" 16 8" 9.0
Information
7 3
W-2-4 1
4" 20 1
4" 7.5 W-27WS 16" 14 8" 10.5
1 1
W-2-5 5
16" 18 3
8" 9.7 W-2-8WS cc 2" 13 2" 10.6
5 7
W-2-6 3
8" 16 3
8" 10.0 W-2-10WS cc 8" 11 16" 14.0
3 7
W-2-12WS cc 4" 10 16" 14.0
Installation
7 3
W-2-7 16" 14 8. 10.4
1 3
W-2-8 1
2" 13 1
2" 11.5 W-5-8WS c 2" 13 8' 8.5
5 3
W-2-10 5
8" 11 7
16" 15.0 W-5-10WS c 8" 11 8" 14.0
3 7
W-2-12 4" 10 16" 15.0 C = Use With W-400 and W-500
Index
7 7
W-2-14 8" 9 16" 15.0 CC = Not For Use With W-400, W-500, and W-900
Wesanco Engineering Catalog 35
C hannel N uts
Standard Finish: Electro Galvanized
Channel Nut With Top-Lock Spring Mini Nut With Short Spring
Use with W-100, W-150, W-200, W-210, W-300, W-400, Use with W-700
W-500, W-800 and W-900
Channel Wt.
Size Thread Length
Part No. Lbs/C
7
W-4-1SN 8" 8
1
W-4-2SN 4" 20 1-18" 9
Channel Wt. W-4-3SN 1-38" 9
Size Thread Thickness W-6-1SN 7
8" 13
Part No. Lbs/C
W-6-0836 36 1.0 W-6-2SN 1-18" 13
#8
W-6-0832 32 1.0 W-6-3SN 3 1-38" 14
8" 16
W-6-1032 32 0.150" 1.0 W-6-4SN 1-58" 15
#10
W-6-1024 24 1.0 W-6-5SN 1-78" 16
W-6-4 1
4" 20 1.0 W-6-6SN 2-18" 16
W-8-2SN 1-18" 15
W-8-3SN 1-38" 16
1
W-8-4SN 2" 13 1-58" 17
W-8-5SN 1-78" 18
W-8-6SN 2-18" 19
W-10-2SN 5 1-18" 22
8" 11
W-10-3SN 1-38" 23
Use with W-200, W-210, and W-300
For Applications In other Channels Consult Factory
36 www.wesanco.com
S mall H ardware
Standard Finish: Electro Galvanized
Channel
Hex Head Cap Screws Lock Washers Roundhead Machine Screws
Channel Nuts
& Hardware
Part No. Size Wt./C
1
W-7430 4" 0.3
3
Part No. Diameter Length Wt./C W-7431 8" 0.7
Fittings
1 1
Part No. Diameter Length Wt./C
W-7400 2" 1 W-7432 2" 1.5 3
1 3 5
W-7470 4" 1.2
W-7401 c 4" 4" 1.3 W-7433 8" 2.6 1
W-7471 4" 1 1.5
Brackets
W-7402 c 1" 1.7
3
W-7472 1-14" 1.8
W-7403
W-7404
4"
1"
4.0
4.5
W-7440 - W-7443 W-7473 1" 2.6
5
Flat Washers W-7474 16" 1-14" 3.0
W-7405 c 1-14" 5.3
Clamps
1-12"
Beam
3
8" W-7475 3.6
W-7406 1-12" 6.1
W-7476 1" 4.1
W-7407 2" 7.6
W-7477 3 1-14" 4.7
Bases
W-7408 2-14" 8.5 8"
Post
15 Part No. Size Wt./C W-7478 1-12" 5.3
W-7409 16" 9.1
W-7440 1
4" 0.7 W-7479 2-12" 7.7
W-7410 1-14" 10
Caps
End
3
W-7411 1-12" 11.6 W-7441 8" 1.5
1
W-7412 1
2" 1-34" 13.2 W-7442 2" 3.5
Clamps
5
W-7413 2" 14.7 W-7443 8" 7.7
W-7414 2-14" 16.0
W-7480 - W-7483
W-7415 2-12" 17.5 Square Nuts
W-7450 - W-7452
Accessories
Electrical
c = provided as slotted machine screw
Fender Washers
W-7401SH - W-7416SH
Part No. Size Wt./C
Concrete
Inserts
Slotted Indented Hex Machine Screw 1
W-7480 4" 0.9
5
W-7481 16" 1.6
Part No. Size Wt./C W-7482 3
8" 2.7
Cushioned
Clamping
1
W-7450 4" x 1-14" 2.0 W-7483 1
2" 5.8
3
W-7451 8" x 1-1 2" 3.0
1
W-7452 2" x 1-12" 4.5
Part No. Diameter Length Wt./C
Supports
Rooftop
W-7490 - W-7492
1 3
W-7401 4" 4" 1.3
3
W-7405 8" 1-14" 5.3
Kep Nuts
W-7416 5
16" 1" 4.1 W-7460 - W-7464
Specifications
Material
Hex Nuts
W-7420 - W-7424
Flathead Machine Screws
Part No. Size Wt./C
Information
1
W-7490 4" 0.9
Design
5
W-7491 16" 1.6
3
W-7492 8" 2.7
Part No. Diameter Length Wt./C Part No. Size Wt./C
Installation
1 5 1
W-7420 4" 8" 0.3 W-7460 4" 0.6
3 5
W-7421 8" 1" 0.7 W-7461 16" 1.2 Threads are Unified American Coarse,
1
W-7422 2" 2" 1.5 W-7462 3
8" 1.6 UNC. Screw, nuts and bolts conform to
W-7423 5
8" 2-14" 2.6 W-7463 1
2" 4.8 ASTM A 307, SAE J429 and ASTM A563.
Index
3
W-7424 8" 2-12" 7.7 W-7464 5
8" 7.33
Wesanco Engineering Catalog 37
T hreaded R od
Standard Finish: Electro Galvanized
W-7124 - W-7128
Threaded Rod
Standard Length 10'
W-7134 - W-7138
Rod Couplers
Hole A Wt.
Part No. Thread
Size Length Lbs/C
1 7
W-7134 4" 20 8" 2
5 7
W-7134A 16" 18 8" 2
3
W-7135 8" 16 1-34" 11
1
W-7136 2" 13 1-34" 11
5
W-7137 8" 11 2-18" 16
3
W-7138 4" 10 2-1 4" 28
38 www.wesanco.com
F lat P late F ittings
Standard Finish: Electro Galvanized
Channel
Flat - without guide Five Hole Splice Plate
94#/C
W-5002 to
Channel Nuts
(rod support
& Hardware
W-5006 situation noted)
Square Washer with
Channel Guide
Fittings
Brackets
Clamps
Beam
Part No. Bolt Hole Wt.
W-5009
Bases
Post
With Guide Without Guide Size Size Lbs/C
W-5002 W-5052 5
16" 11
32" 18 Four Hole
Caps
Splice plate
End
3 7
W-5003 W-5053 8" 16" 18
1 9 (Hardware not included)
78#/C
W-5004 W-5054 2" 16" 17
Clamps
5 11
W-5005 W-5055 8" 16" 16
W-5006 W-5056 3
4" 13
16" 16 W-5012
Three Hole
Accessories
Electrical
W-5007 Swivel Plate
75#/C
Two Hole
Splice Plate
Concrete
38#/C
Inserts
Cushioned
Clamping
W-5008
Three Hole
Supports
Rooftop
Splice Plate
58#/C
W-5011
Specifications
Two Hole Material
Swivel Plate
56#/C
W-5021
Information
Design
Parallel Splice
Installation
Plate
38#/C
Index
W-5022 W-5025
Extended Flat Angle Plate
Tee Plate
80#/C
80#/C
W-5023 W-5026
Cross Plate Four Hole Gusset Plate
95#/C 105#/C
W-5024 W-5027
Four-Hole Corner Plate Five-Hole Gusset Plate
100#/C 150#/C
40 www.wesanco.com
90 A ngle F ittings
Standard Finish: Electro Galvanized
W-5102 W-5106
Channel
Two-Hole Rack Connector Two-Hole Rack Adjustment Angle
38#/C 38#/C
Channel Nuts
& Hardware
Fittings
Brackets
W-5107
Clamps
Beam
W-5103 Two Hole
Two-Hole End Connector Adjustment Angle
Bases
65#/C
Post
38#/C
Caps
End
Clamps
Accessories
Electrical
W-5108
Two Hole
Concrete
Inserts
Adjustment Angle
85#/C
Cushioned
Clamping
W-5104 W-5109
Two-Hole Angle Four-Hole
Supports
Rooftop
(Indented) Rack Splice Connector
38#/C 105#/C
Specifications
Material
Information
Design
W-5105
Two Hole
Adjustment Angle
Installation
W-5111 W-5113
Three Hole Adjustment Angle Three Hole
(slot: 916" x 1 12") End Connector
66#/C 58#/C
W-5110
Three-Hole Rack Splice Connector W-5115
70#/C Three Hole Rack
Corner Angle
58#/C
W-5117
Five-Hole Corner Splice Connector
W-5112 150#/C
Three-Hole Rack Connector
58#/C
42 www.wesanco.com
90 A ngle F ittings
Standard Finish: Electro Galvanized
Channel
Gusset Corner Angle Universal Corner Angle
125#/C 146#/C
Channel Nuts
(W-5124W has
& Hardware
Welded Corner)
Fittings
Brackets
Clamps
Beam
Bases
Post
Caps
End
Clamps
Accessories
Electrical
W-5125
Four-Hole corner Connector
78#/C
Concrete
Inserts
(Hardware not included)
Cushioned
Clamping
(Hardware not included)
Supports
Rooftop
Corner Angle 62#/C
78#/C
Specifications
Material
Information
Design
Installation
Index
Y - Channel Wt.
Part No. Use with
Height Lbs/C
W-5209 W-101 4-78" 93
W-5211 W-100 2-716" 67
W-5213 W-300 1-38" 53
13
W-5215 W-400, W-500 16" 47
W-5218 W-800 1" 47
W-5210
Zee Supports
70#/C
W-5307 W-5308
Channel
Slotted "U" Supports Slotted "U" Supports
for W-200, W-210 for W-200, W-210
Channel Nuts
& Hardware
Fittings
Brackets
Clamps
Beam
Bases
Post
Caps
End
Clamps
Accessories
Electrical
W-5310 W-5311
Slotted "U" Supports "U" Supports
for W-200, W-210 for W-100
Concrete
110#/C
Inserts
Cushioned
Clamping
Supports
Rooftop
Specifications
Material
Information
Design
Installation
Index
W-5312
"U" Supports
for W-200, W-210
88#/C
W-5313
"U" Supports
for W-300
84#/C
W-5315
"U" Supports
for W-400, W-500
71#/C
W-5316
"U" Supports
for W-150, W-201
128#/C
46 www.wesanco.com
U S hape F ittings
Standard Finish: Electro Galvanized
Channel
"U" Support
(Double Channel)
Channel Nuts
100#/C
& Hardware
Fittings
Brackets
Clamps
Beam
Bases
Post
Caps
End
Clamps
Accessories
Electrical
Concrete
Inserts
W-5318
Cushioned
Clamping
"U" Support
(W-800 Channel)
76#/C Wt.
Part No. X
Lbs/C
Supports
Rooftop
W-5324 4" 80
W-5325 5" 89
W-5326 6" 101
Specifications
W-5327 7" 112 Material
W-5328 8" 124 Information
Design
Installation
Index
W-5342 W-5344
Two Hole Splice Two Hole Splice
78#/C 125#/C
W-500 W-200
Shallow Style Deep Style
W-5343 W-5346
Three Hole Splice Three Hole Splice
130#/C 198#/C
W-500 W-200
Shallow Style Deep Style
W-5345
Four Hole Splice
265#/C
W-200
(Hardware not included) Deep Style
48 www.wesanco.com
B racing
Standard Finish: Electro Galvanized
Channel
Wt.
Part No. A B C
Lbs/C
Channel Nuts
& Hardware
W-5413 60 4-2132" 4-58" 100
W-5415 45 4-1516" 4-1132" 100
Fittings
Brackets
Clamps
Beam
Bases
Post
Four-Hole Open Angle
Caps
End
Wt.
Part No. A
Lbs/C
Clamps
W-5443 60 78
W-5445 45 78
W-5447 30 78
Accessories
Electrical
Two-Hole Open Angle
Concrete
Inserts
Wt.
Part No. A B C
Lbs/C
W-5423 60 3-38" 1-7 8" 50
Cushioned
Clamping
W-5425 45 3" 2-516" 50
W-5427 30 3-14" 2-116" 50
Supports
Rooftop
Specifications
Material
Information
Wt.
Part No. A B
Lbs/C
Installation
W-5463 60 2-2532" 58
W-5465 45 3-116" 58
Index
W-5485
Double Adjustable Angle Brace Fitting
500#/C
Part Wt.
A B
No. Lbs/C
W-5472 12" 10-18" 170
W-5473 16-58" 13-38" 230
W-5474 18" 14-38" 238
W-5475 24" 18-58" 315
50 www.wesanco.com
W ing F ittings
Standard Finish: Electro Galvanized
W-5510 W-5512
Channel
Three-Hole Right Corner Angle Four-Hole 90 Degree Corner Angle
56#/C 81#/C
Channel Nuts
& Hardware
Fittings
Brackets
Clamps
Beam
Bases
Post
Caps
End
Clamps
Accessories
Electrical
(Hardware not included) (Hardware not included)
W-5511 W-5513
Concrete
Inserts
Three-Hole Left Corner Angle Five-Hole Two Side Angle Connector
56#/C 93#/C
Cushioned
Clamping
Supports
Rooftop
Specifications
Material
Information
Design
Installation
W-5514 W-5515
Six-Hole Three Side Corner Angle Connector Eight-Hole 90 Corner Angle Connector
110#/C 137#/C
W-5516
Eight-Hole Gusseted Corner
Angle Connector
185#/C
52 www.wesanco.com
W ing F ittings
Standard Finish: Electro Galvanized
W-5517 W-5518
Channel
Nine-Hole Three Side Angle Connector Six-Hole 90 Corner Angle Connector
175#/C 115#/C
Channel Nuts
& Hardware
Fittings
Brackets
Clamps
Beam
Bases
Post
Caps
End
Clamps
Accessories
Electrical
(Hardware not included) (Hardware not included)
Concrete
Inserts
W-5519
Eight-Hole Opposing Side Angle Connector
Cushioned
Clamping
150#/C
Supports
Rooftop
Specifications
Material
Information
Design
Installation
W-6603
Trolley Beam Joint Support
240#/C
(12"x2-34" HHCS and 12" Nut Washer
not included)
For W-200 and W-210 Series channel.
Allowable load 2,500#
W-6602
Two Wheel Trolley
59#/C
Trolley designed to fit W-200 and
W-210 series channel. Same
construction as W-6600.
Allowable load 300# max.
54 www.wesanco.com
S helf B rackets
Standard Finish: Electro Galvanized
W-5601 - W-5606
Channel
Shelf Bracket (Right Hand Illustrated)
Channel Nuts
& Hardware
Fittings
Shelf Brackets
Brackets are 12ga steel, electro-galvanized.
Brackets
Furnished with 38" x 1" slotted holes and 932' round holes,
as illustrated.
Connection to upright requires 38" channel nut and HHCS.
Clamps
Beam
Part No. (Order separately)
Wt.
Left Right A B C
Lbs/C Design Uniform Load
Hand Hand (Channel Upright Listed)
Bases
Post
W-5601 W-5602 6" 1-1516" 3" 56 W-200 Channel (12Ga) 300#
W-5603 W-5604 8" 2-7 16" 5" 82 W-210 Channel (14Ga) 250#
Caps
2-1516" Safety Factor 2-12
End
W-5605 W-5606 10" 7" 112
Clamps
W-5607 - W-5618
Accessories
Shelf Bracket (Right Hand Illustrated)
Electrical
Concrete
Inserts
Cushioned
Clamping
Supports
Rooftop
Specifications
Material
Shelf Brackets
Brackets are 12ga steel, electro-galvanized.
Part No. Furnished with 38" x 1" slotted holes and 932' round holes,
Wt.
Information
W-5611 W-5612 16" 4-7 16" 5" 198 (Channel Upright Listed)
W-5613 W-5614 18" 4-1516" 6" 218 W-200 Channel (12Ga) 300#
W-5615 W-5616 20" 5-7 16" 7" 258 W-210 Channel (14Ga) 250#
W-5617 W-5618 22" 5-1516" 8" 348 Safety Factor 2-12
Index
W-5619 W-5626
Shelf Bracket
(Right Hand Illustrated)
56 www.wesanco.com
C hannel B rackets
Standard Finish: Electro Galvanized
W-5631 - W-5634
Channel
Design Uniform Load
(when attached to listed upright column)
Channel Nuts
& Hardware
Wt.
Part No. A W-200 W-210
Lbs/C
W-5631 6" 150 1200# 800#
W-5632 12" 250 600# 400#
Fittings
W-5633 18" 350 400# 270#
W-5634 24" 450 300# 200#
When installed in inverted position use 60% of loads shown.
Brackets
Safety Factor 2-12
W-5635 - W-5638
Clamps
Beam
Design Uniform Load
(when attached to listed upright column)
Bases
Post
Wt.
Part No. A W-200 W-210
Lbs/C
Caps
End
W-5635 6" 150 1200# 800#
W-5636 12" 250 600# 400#
Clamps
W-5637 18" 350 400# 270#
W-5638 24" 450 300# 200#
When installed in inverted position use 60% of loads shown.
Accessories
Safety Factor 2-12 (Hardware not included)
Electrical
W-5641 - W-5642
Design Uniform Load
Concrete
Inserts
(when attached to listed upright column)
Wt.
Part No. A W-200 W-210
Lbs/C
Cushioned
Clamping
W-5641 6" 190 1600# 1200#
W-5642 12 290 800# 600#
Do not install in inverted position.
Supports
Rooftop
Safety Factor 2-12
Specifications
W-5645 - W-5646 Material
Lbs/C
W-5645 6" 190 1600# 1200#
W-5646 12" 290 800# 600#
Installation
Note: When brackets are used for mechanical supports, load capacities should
conform to American Standard Code for Pressure Piping.
Index
Note: Hardware shown for application definition only. Not included. (Hardware not included)
W-5647 - W-5648
Illustrated With Channel Up Bracket Arms
are W-200 Channel
Wt.
Part No. A W-200 W-210
Lbs/C
W-5647 18" 430 600# 450#
W-5648 24" 530 450# 330#
Safety Factor 2-12
W-5652 - W-5656
Bracket Arms Are W-201 Channel
Wt.
Part No. A W-200 W-210
Lbs/C
W-5652 12" 515 2000# 1400#
W-5653 18" 715 1300# 900#
W-5654 24" 915 1000# 700#
W-5655 30" 1115 800# 560#
W-5656 36" 1315 650# 450#
Safety Factor 2-12
58 www.wesanco.com
C hannel B rackets
Standard Finish: Electro Galvanized
Channel
Part No. W-200 W-200 W-210 W-210
Bracket Brace Adapter
275#/C SF * 2-12 5 2-12 5
W-5650 12,400 6,200 8,600 4,300
Channel Nuts
Design Moment (Inches/Lbs)
& Hardware
(Channel Upright Listed) W-5651 6,000 3,000 4,200 2,100
* S.F. (Safety Factor)
Applies to Bracket Brace Adapter/Listed Upright Only and not to Strength of Arm.
Fittings
Brackets
Clamps
Beam
Bases
Post
Caps
End
Clamps
W-5650 W-5651
Accessories
Electrical
For use with: W-150, For use with: W-200,
W-201, or W-211 Secure Bracket Arm To Brace Using W-2-8 and W-7409. W-210, W-401, or W-501
Do Not Use Thru Bolt In Bracket W-5650 Or W-5651
(Hardware not included) (Hardware not included)
Concrete
Inserts
W-5661 - W-5664
Cushioned
Bracket Arms Are W-200 Channel
Clamping
Supports
Design Uniform Load
Rooftop
(when attached to listed upright column)
Wt.
Specifications
Part No. A W-200
Lbs/C Material
W-5661 6" 153 1600#
W-5662 12" 248 800#
W-5663 18" 342 550#
Information
When brackets are used for mechanical supports, load capacities should conform to
requirements of the American Standard Code for pressure piping.
c c Consider gusset clearance when utilizing stud bolt/anchor condition.
Index
W-5669
W-5671 W-5673
Load
Wt.
Part No. W-200 W-210
Lbs/C
12 Gauge 14 Gauge
W-5669 169 800 600
W-5671 193 800 600
W-5673 257 900 800
Safety Factor 2-12
60 www.wesanco.com
G irder S tyle B rackets
Standard Finish: Electro Galvanized
Channel
W-5677
Channel Nuts
& Hardware
375#/C W-5675
289#/C
Fittings
Brackets
Clamps
Beam
Bases
Post
Caps
End
Clamps
Load
Wt.
Part No. W-200 W-210
Lbs/C
12 Gauge 14 Gauge
Accessories
Electrical
W-5675 289 900 800
W-5677 375 1,200 900
Safety Factor 2-12
Concrete
Inserts
Note: when used for mechanical supports, load capacities
of brackets and fittings should be in compliance with the
Cushioned
Clamping
American Standard Code for pressure piping.
Supports
Rooftop
Specifications
Material
Information
Design
Installation
Index
W-1007-Y W-1010-X
Use W-901 Strut Diamond back extended riser bracket
(E/G HRDWR.) #/C DBC
#/C DBC
(also available W-1007 E-Y with (3) W-6162-HDGAF;
each clamp with Everdur hardware)
W-1012-X
Strap back extended riser bracket
#/C DBC
W-1011-X
Diamond back extended riser bracket
#/C DBC
Channel
X or Y: 6, 8, 10, 12, 16, 18 and 24 inches
W-1016-X
Channel Nuts
& Hardware
Strap back extended riser bracket with end wrap brace
#/C DBC
Fittings
Brackets
Clamps
Beam
Bases
Post
Caps
End
Clamps
Accessories
Electrical
W-1013-X
Strap back extended riser bracket with
Concrete
Inserts
bottom attached brace.
#/C DBC
Cushioned
Clamping
Supports
Rooftop
Specifications
Material
Information
Design
Installation
Index
W-1015-X W-1019-Y
Cross back extended Low profile diamond back with
riser bracket #/C DBC horizontal strut riser.
#/C DBC Appropriate (hot dipped
galvanized) end caps available
on any unit (optional)
W-1017
189#/C (hardware not incl.)
1-58" x 1316"
Standard channel 4" square plate horizontally radiused
(5-58" nominal corner to corner)
Welded top and bottom at apex of radiused back plate
W-1017-A-Y
(Standard}
#/C DBC
W-1017-AR-A-Y
(Anti-rotation}
#/C DBC
-A-Y Includes:
W-1017 Bracket,
W-200 Channel (punched),
Assembly hardware included:
W-7410 E/G 12" x 1-14" HHCS
W-7432 E/G 12" Lock Wash
W-7463 E/G 12" Hex Nut
64 www.wesanco.com
U tility B rackets
Standard Finish: Hot Dip Galvanized (brackets)
Standard dimensions available
Channel
X or Y: 6, 8, 10, 12, 16, 18 and 24 inches
W-1021-X/Y
Channel Nuts
& Hardware
Extended profile diamond back with Appropriate (hot dipped galvanized) end caps
horizontal riser strut available on any unit (optional)
#/C DBC
Fittings
Brackets
Clamps
Beam
Bases
Post
Caps
End
Clamps
Accessories
Electrical
W-1023-Y Use appropriate:
Concrete
Inserts
1
Utility vault ladder rung 2" dia. hex head cap screws (2)
#/C TBD and channel nuts (2)
(not included)
Cushioned
Clamping
Supports
Rooftop
Specifications
Material
Information
Design
W-5714 W-5713
Two-Hole Beam Clamp One-Hole Beam Clamp
90#/C 30#/C
(Use in Pairs)
66 www.wesanco.com
B eam C lamps
Standard Finish: Electro Galvanized
Channel
position against flange(s) dimple beam at set screw (recommended).
Channel Beam Clamp
(Used In Pairs)
Channel Nuts
& Hardware
Allowable Wt.
Part No. Duty A B
Load Lbs/C
W-5715 Light Duty 1-34" 1
4" 450# 41
W-5716 Heavy Duty 1-12" 3
8" 1,000# 62
Fittings
Brackets
Cone point set
screw included
Clamps
Beam
Bases
Post
Caps
End
Clamps
Accessories
Electrical
Concrete
Inserts
W-5717
Cushioned
Clamping
Channel Beam Clamp
(Thick Flange) Cone point set
83#/C screw included
(Used In Pairs)
Supports
Rooftop
Allowable Load
Specifications
Per Pair: 900# Material
Information
Design
Installation
Index
Wt. Allowable
Part No. A B C
Lbs/C Load (ea.)
1
W-5721 4"-20
5 1 3
W-5722 16"-18 8" 8" x 1-12" 65 650#
3
W-5723 8"-16
(Shown Inverted, W-5724 3
8"-16 3 1
rating reduced 50%) 1 16"' 2" x 1-12" 100 1100#
W-5718 W-5725
W-5726 1
2"-13
2'-13 1 1
3
8" Rod Clamp 5 4" 2" x 1-12" 130 1600#
W-5727 8"-11
33#/C 5
Loads have a safety factor of W-5728 8"-11
Max. Load 400 Lbs. 3
5
16" 5
8" x 1-12" 160 2400#
3.5 per MSS SP-58 W-5729 4"-10
(Hardware not included)
Wt. Allowable
Part No. A B C
Lbs/C Load (ea.)
1
W-5731 4"-20 105
5 1 3
W-5732 16"-18 8" 8" x 2" 105 800#
3
W-5733 8"-16 105
3
W-5734 8"-16 3 1 160
1 16" 2" x 2" 1300#
W-5735 2"-13 160
1
W-5736 2"-13 1 1 200
5 4" 2" x 2" 1900#
W-5737 8"-11 200
5
W-5738 8"-11 5 5 250
3 16" 8" x 2" 2800#
W-5739 4"-10 250
(Hardware not included)
68 www.wesanco.com
B eam C lamps
Standard Finish: Electro Galvanized
W-5708
Channel
"U" Bolt Beam Clamp (Long)
92#/C
Channel Nuts
& Hardware
(Used In Pairs)
Installation Load
Fittings
Note: For Channel
Beam Clamps
Brackets
Uniform loads are based upon opposing style clamps used in pairs,
Clamps
installed against the flanges of the beam. it is recommended that
Beam
the beam be dimpled at set screw contact location(s)
Bases
Post
Use with:
Caps
End
W-100, W-150, W-201
Allowable Load 1,000# ea.
Clamps
W-5702 to W-5705 W-5709
Accessories
Electrical
Beam Clamp "U" Bolt Beam Clamp (Short)
(Used In Pairs) 82#/C
(Used In Pairs)
Concrete
Inserts
Cushioned
Clamping
Supports
Rooftop
Cone point set
Specifications
Material
screw included Information
Design
Wt. Allowable
Part No. A Channel
Lbs/C Loads (Ea.)
3-12"
Installation
Bottom Rod
Against Beam
(Recommended)
W-5750 W-5751
It Is Recommended
All Purpose Swivel Hanger
That Beams Be
Beam Clamp Dimpled At Set Screw
29#/C
43#/C Contact Location
W-5750
Cone point set
300# screw included
Locknut
in First
Hole
500# W-5751
Locknut in
Second Hole
20
Swivel
70 www.wesanco.com
P ost B ases
Standard Finish: Electro Galvanized
W-5810 W-5811
Channel
Rectangular Plate Eight-Hole Post Base Eight-Hole Welded Corner
Shown with: W-200
Single Channel Tall Clevis Post Base (5")
Channel Nuts
& Hardware
286#/C 294#/C
Fittings
Brackets
Clamps
Beam
Bases
Post
Base Plate
(Holes: 916")
Caps
End
(Hardware not included)
Clamps
4" x 6" Base Plate
Shown with: W-200 (Holes: 916")
W-5810 FL
(1-58" x 1-58") Rectangular Plate Eight-
Hole Post Base Single
Accessories
Electrical
Channel Tall Clevis
286#/C
(Hardware not included) Shown with: W-200
(1-58" x 1-58")
Concrete
Inserts
W-5812 4" x 6" Base Plate
(Holes: 916")
Rectangular Plate 6 Hole Post Base Double
Cushioned
Clamping
Channel Short Clevis Shown With: W-201
295#/C
Supports
Rooftop
(Hardware not included)
W-5813
Specifications
Material
Seven-Hole Post Base Single
Channel Short Clevis
300#/C
Shown With: W-501
Information
Design
Installation
(Hardware not included) (Hardware not included) 6" x 6" Base Plate (Holes: 34")
Wesanco Engineering Catalog 71
P ost B ases
Standard Finish: Electro Galvanized
W-5814 W-5815
Ten-Hole Post Base Single Eight-Hole Post Base Double
Channel Tall Clevis Channel Short Clevis
327#/C 323#/C
Shown with W-151
Very deep channel may
require relief to clear a bolt/
anchor. (shown with miter
relief)
Shown with:W-202
Mitered Relief
W-5814SQ
Ten-Hole Post Base Single
Channel Tall Clevis Base Plate (Typical 6" X 6") In
Standard Position
372#/C
Shown with W-200
W-5816/5816SQ
Twelve-Hole Post Base Double
Channel Tall Clevis
400#/C
Shown with W-204
72 www.wesanco.com
E nd C aps
Standard Finish: Electro Galvanized
Channel
Wireway End Cap For End Cap with knock-outs
W-200 Channel 26#/C
Channel Nuts
& Hardware
13#/C
Fittings
Brackets
W-5910 to W-5938 Part No.
Channel
Usage
UL Listed End Caps
Clamps
W-5910 W-100
Beam
W-5930 W-200
W-5931 W-210
Bases
Post
W-5933 W-300
W-5935 W-500
W-5935 W-900
Caps
End
W-5938 W-800
Clamps
Channel
Part No. Size
Usage
1
A W-5940 2" W-200
Accessories
Electrical
3
B W-5941 4" W-200
1
C W-5942 2" W-300
W-5900 to W-5935 D W-5943 3
4" W-300
Cover Plastic End Caps (Hardware not included)
Concrete
Inserts
W-5900-M to W-5935-M W-5952 & W-5958
Form Fit Plastic End Caps
Anchor End Caps
Cushioned
Clamping
Part No. Channel
Cover Form Fit Usage 21#/C
W-5900 W-5900-M W-201
W-5930 W-5930-M W-200, W-501
Supports
Rooftop
W-5935 W-5935-M W-500
Specifications
Material
Information
Design
Installation
Index
Slotted
Nominal O.D. Wt. Allowable
Part No. Gauge Indented
Size Size Lbs/C Load (ea.)
Hex Cap Screw
W-6125 - 6178 W-6125 3
1
8" 0.675 10# 16
400#
1
1
4 x 3 4
W-6126 2" 0.840 11# 16 4 x 3 4
Rigid Steel Conduit Series (Iron Pipe) 3 1
W-6128 4" 1.050 15# 14 4 x 3 4
1
W-6130 1" 1.315 17# 14 600# 4 x 3 4
W-6132 1-14" 1.660 19# 14 1
4 x 1
W-6134 1-12" 1.900 29# 12 5
16 x 1
5
W-6138 2 2.375 34# 12 800# 16 x 1
W-6142 2-12" 2.875 40# 12 5
16 x 1
5
W-6146 3 3.500 47# 12 16 x 1
W-6150 3-12" 4.000 62# 11 3
8 x 1-14
3
W-6154 4 4.500 67# 11 8 x 1-14
3
W-6162 5 5.563 80# 11 8 x 1-14
1000# 3
W-6170 6" 6.625 102# 10 8 x 1-14
3
W-6174 8" 8.625 116# 10 8 x 1-14
3
W-6176 10" 10.750 132# 10 8 x 1-14
3
W-6178 12" 12.750 150# 10 8 x 1-14
Each clamp consists of two halves one
kept nut and one slotted hex head cap screw.
Ref: pages 117 - 119 for Special Materials Specification
74 www.wesanco.com
S trut C lamps
Standard Finish: Electro Galvanized
Channel
Nominal Wt. Allowable
Part No. Gauge Indented
Size Lbs/C Load (ea.) O.D Tubing Series
Hex Screw
W-6224 1
4" 8# (copper tubing, glass or ceramic tubes, and transite pipe)
Channel Nuts
& Hardware
3
W-6225 8" 8#
1
W-6226 2" 9# 1
5 16 400# 4 x 3 4
W-6227 8" 10#
3
W-6228 4" 11#
Fittings
7
W-6229 8" 12#
W-6230 1" 14#
W-6231 1-18" 15#
Brackets
W-6232 1-14" 16# 1
14 600# 4 x 3 4
W-6233 1-38" 17#
W-6234 1-12" 18#
W-6235 1-58" 19#
Clamps
Beam
W-6034 1-34" 29#
W-6237 1-78" 28#
Bases
W-6238 2" 31#
Post
W-6239 2-18" 32#
W-6240 2-14" 33#
Caps
End
W-6138 2-38" 34#
W-6242 2-12" 35#
Clamps
W-6243 2-58" 37# 12 800# 5
16 x 1
W-6244 2-34" 38#
W-6142 2-78" 40#
Accessories
Electrical
W-6246 3" 41#
W-6247 3-18" 43#
W-6248 3-14" 45#
W-6249 3-38" 46#
Concrete
3-12"
Inserts
W-6146 47#
W-6251 3-58" 56#
W-6252 3-34" 58#
Cushioned
W-6253 3-78" 60#
Clamping
W-6150 4" 62#
W-6255 4-18" 62#
W-6256 4-14" 64#
Supports
Rooftop
W-6257 4-38" 66#
Allowable Load
W-6154 4-12 67#
11 (Safety Factor 5)
W-6259 4-58" 70#
Specifications
W-6260 4-34" 72# Special Materials Pipe Clamps Material
W-6261 4-78" 73# (Universal Clamps excluded)
3
W-6262 5 74# 1000# 8 x 1-14
Add Suffix to
W-6263 5-18" 76# Material Example
part Number
W-6264 5-14" 77#
Steel Clamp
Information
Everdur Hardware
W-6266 5-12" 79#
Copper Plated Clamp
W-6267 5-58" 88# C/P W-6130 C/P
and Hardware
W-6268 5-34" 90# Aluminum AL W-6130 AL
Installation
W-6269 5-78" 92# Stainless steel type 304 st-304 W-6130 st-304
W-6270 6" 94# 10 Stainless steel type 316 st-316 W-6130 st-316
W-6274 8" 123#
For assembled clamps -A W-6130-A
W-6278 10" 106#
Index
W-7724 - W-7730
One-Hole Tubing Clamps
W-7826 - W-7870
Standard Pipe Straps
B C
Pipe A Wt.
Part No. Material Hole
Size Length Lbs/C
Thickness Size
1
W-7826 2" 3 24
3
W-7828 4" 3-14 28
W-7830 1" 3-916 1
8" 9
32" 32
W-7832 1-14" 3-1316 35
W-7834 1-12" 4-116 40
W-7838 2 5-1316 95
W-7842 2-12" 6-14 116
W-7846 3" 7 135
W-7850 3-12" 7-78 1
4" 7
16" 155
W-7854 4" 8 180
W-7862 5" 9-18 195
W-7870 6" 10-516 240
76 www.wesanco.com
E lectrical A ccessories
Standard Finish: Electro Galvanized (ASTM B633-SC-3)
All items this series listed UL5B
W-6420 & W-6422
Channel
Single Channel Fixture Hanger
Channel Nuts
& Hardware
Wt.
Part No. I.D. X
Lbs/C
W-6420 3" 25
Fittings
W-6422 4" 27
Brackets
(Hardware not included)
Clamps
Beam
W-6424 & W-6426
Bases
Post
Double Channel Fixture Hanger
Caps
End
Part I.D. Wt.
Clamps
No. X Lbs/C
W-6424 4-1516" 45
W-6426 5-1516" 47
Accessories
Electrical
(Hardware not included)
Concrete
Inserts
W-6442 & W-6443
Cushioned
Clamping
Conduit Connector
Supports
Rooftop
Use with I.D. Wt.
Part No.
Conduit A Lbs/C
Specifications
1 Material
W-6442 2" 3" 25
3
W-6443 4" 4" 27
Information
Design
Installation
Index
W-6433
W-6439
Standard Raceway Stud Plate
W-6435
W-6440
(4) hole tapped splice plate W-6439
(opt.) with 4 screws W-6440
10#/C
(can be substituted for state plate assy.)
W-6445 W-6449
Receptacle Box Outlet Box Connection Fitting
(Face Box 78#/C Plate) 35#/C
Assembly includes
Westrut nuts and Flat
Head Machine Screws
78 www.wesanco.com
E lectrical A ccessories
Standard Finish: Electro Galvanized (ASTM B633-SC-3)
All items this series listed UL5B
W-6462 W-6463
Channel
1 1
Aluminum Wiring Stud 2"-14 Thread 1- 8" Long Shoulder Bolt 38" X 2"
8#/C 9#/C
Channel Nuts
& Hardware
Fittings
Brackets
Clamps
Beam
Bases
Post
W-6460 W-6461
Fixture Stud Fixture Nut
Caps
End
4#/C 2#/C
Clamps
Accessories
Electrical
Concrete
Inserts
Cushioned
Clamping
W-6500
Supports
Rooftop
Closure Strip (19 Ga.)
47#/Cft
W-6500 Specifications
Material
Channel
Spot Concrete Insert Spot Concrete Insert Nuts
50#/C Standard Finish: Electro Galvanized
Channel Nuts
& Hardware
12 Ga.
Fittings
23 Ga. tabs
Brackets
knock-out
Clamps
Beam
(Insert nut)
Standard Finish:
Bases
Post
Electro Galvanized
Caps
Tapped A Wt.
End
Part No.
Size Lbs/C
1
W-7024 4"-20 8
Clamps
Allowable load 800#, safety Factor of 5 based on adequate 3
W-7025 8"-16 11
concrete. 1
W-7026 2"-13 15
Designed to be used with 14", 38", 12", 58", 34" and 78" spot
Accessories
5
W-7027 8"-11 19
Electrical
concrete insert nuts W-7024 - W-7029 3
W-7028 4"-10 17
A 78" x 1-58" knock-out is removed after concrete pour. The spot W-7029 7
8"- 9 15
concrete insert nut is placed in the slot, and then the rod is screwed
into the nut. The nut is secured in place by turning the rod. Lateral
Concrete
Inserts
adjustment is made by loosening the nut and relocating. When
selecting rod size, refer to "Load Ratings" of Thread Hanger Rods"
chart on page 38.
Cushioned
Clamping
W-9320 Eliminates Dual Inventories Optional Channel
No separate handling of inserts Nut Sizes Available
Springless Nut Platform
and nuts.
Supports
1.5#/C
Rooftop
Patent No. 4948313 Labor Savings
No field installation of nuts.
Loss Prevention
Specifications
Material
Eliminates job site storage problems.
Easy Alignment
No toppling or disorientation of nuts during alignment.
Information
Design
For use in curtain wall anchoring applications and other areas no closer than 2" to either end. The distance between the insert
where heavy loads are anticipated. The recommended design load centerline and the concrete edge must be a minimum of 2-34".
of W-9318 used in curtain wall anchoring applications and properly
Installation
All series 93 inserts come complete with anchor end caps and
embedded in normal weight, 3000 psi minimum compressive W-6518 plastic closure strip or polyethalene foam to inhibit concrete
strength concrete is 6,000 pounds. seepage. All nuts and fittings designed for the W-7350/70 insert
The above recommended design load is developed using two (2) series are applicable. Standard finish Gold electro galvanized
W-2-8 channel nuts located at no less than 3" apart on center and
Index
Allowable
Part No.
Load
W-7250 800#
Tab
W-7251 1000#
W-5930
End Cap
Standard finish: electro galvanized
Channel
12 Gauge, Continuous Concrete Inserts
When ordering specify finish. Available in plain, pre-galvanized,
Channel Nuts
& Hardware
hot dip galvanized after fabrication, 304 and 316 stainless steel.
Allowable
Part No.
Fittings
Load
W-7350 800#
Rigid Foam Filler shown W-7351 1000#
Brackets
partially removed
W-7352 1200#
W-7353/70 2000#/ft.
Clamps
W-7353 to W-7370
Beam
Typical Anchor Tab Detail
Insert is shipped complete with styrofoam filler and end caps.
Bases
Post
Allowable loads are based on adequately reinforced concrete
with 3,000 psi minimum compressive strength.
W-5933
Caps
End
End Cap
Clamps
Accessories
Electrical
End Cap Wt. /
Part No. Size
Number CPCS
Concentrated load on the end 2" of W-7352 thru W-7370
Concrete
Inserts
should not exceed 1,000#. Inserts must be surrounded W-7350 4" 100#
by sufficient concrete to conform to design shear stress. W-7351 6" 130#
W-5953
Concrete insert should be nailed to form every 16" to 24" W-7352 8" 160#
Cushioned
Clamping
W-7353 * 12" 220#
W-7354 16" 250#
W-7355 20" 310#
W-7350 to W-7352 W-7356 24" 370#
Supports
Rooftop
Typical Anchor Detail W-7357 32" 490#
(W-7353 utilizes tab channel) W-7357A 36" 550#
Channel W-7358 40" 610#
Specifications
without Tabs
W-7359 4' 730# Material
W-7360 5' 910#
W-7361 6' 1,090#
W-5933
W-7362 7' 1,270#
Information
Allowable
Part No.
Load
W-7550 500#
W-7551 750#
W-7552 1000#
W-7553 - W-7570 1500#/ft
W-7553 to W-7570
Typical Anchor Tab Detail
Insert is shipped complete with styrofoam filler and end caps.
Allowable loads are based on adequately reinforced concrete with
3,000 psi minimum compressive strength.
W-5938
End Cap
Finish: Electro-galvanized
Channel
12 Gauge, Continuous Concrete Inserts
When ordering specify finish. Available in plain, pre-galvanized,
Channel Nuts
& Hardware
Waterproof hot dip galvanized after fabrication, 304 and 316 stainless steel.
Sealer Tape
Allowable
Part No.
Load
Fittings
W-7954 - W-7970 1500#/ft
Brackets
Clamps
Beam
W-7954 to W-7970
Typical Anchor Tab Detail
Bases
Post
Insert is shipped complete with styrofoam filler and end caps.
Allowable loads are based on adequately reinforced concrete with
Caps
End
3,000 psi minimum compressive strength.
Clamps
W-5935
Accessories
Electrical
End Cap
Finish: Electro-galvanized
Concrete
Inserts
Concentrated load on the end 2" of W-7954 thru W-7970
Cushioned
End Cap Wt. /
Clamping
should not exceed 750#. Inserts must be surrounded by Part No. Size
Number CPCS
sufficient concrete to conform to design shear stress.
W-7954 16" 213#
Concrete insert should be nailed to form every 16" to 24"
W-7955 20" 263#
Supports
Rooftop
W-7956 24" 313#
W-7957 32" 414#
W-7957A 36" 464#
Specifications
W-7958 40" 510# Material
W-7959 4' 615#
W-7960 5' 766#
W-7961 6' 916#
W-5935
W-7962 7' 1079#
Information
Design
W-2-8WS (Typ. 2)
W-9320 (Typ. 2)
W-9318
Factory
Applied
Sealer Typ.
W-6518
Plastic Closure Strip
W-5918
(Typ. 2)
W-9318
Concrete insert
With Studs
32#/C
86 www.wesanco.com
H eavy D uty C ontinuous
C oncrete I nserts
W-9350 - W-9370 Allowable
Channel
Part No.
Load
10 Gauge Concrete Insert with Welded Studs
W-9350 1330#
328#/C.ft. W-9351 2000#
Channel Nuts
& Hardware
W-9352 2660#
W-9353 - W-9370 4000#/ft
Fittings
caps and W-6518 plastic closure strip or polyethalene
The foam and nailing holes to attach and inhibit concrete
recommended seepage. All nuts and fittings designed for the
design load is W-7350/70 insert series are applicable.
Brackets
developed using two (2) Standard finish "Gold" electro galvanized
W-2-8 channel nuts located
at no less than 3" apart on center
Clamps
and no closer than 2" to either end. The
Beam
distance between the insert centerline and the
concrete edge must be a minimum of 2-34"
Bases
Post
W-5933
Caps
End
End Caps
Finish:
Clamps
Electro-galvanized
Accessories
Electrical
End Cap Wt. /
Part No. Size
Number CPCS
Concrete
Inserts
For use in areas where heavy loads are anticipated. The W-9350 4" 110#
recommended design load of W-9353 used in W-9370 anchoring W-9351 6" 164#
W-5918
applications and properly embedded in normal weight, 3,000 psi W-9352 8" 219#
Cushioned
Clamping
minimum compressive strength concrete is 4,000 pounds W-9353 * 12" 328#
W-9354 16" 438#
W-9355 20" 547#
W-9350 to W-9352 W-9356 24" 656#
Supports
Rooftop
Typical Anchor Detail W-9357 32" 875#
Channel without
W-9353 utilizes stud channel W-9357A 36" 984#
Studs
W-9358 40" 1100#
Specifications
W-9359 4' 1312# Material
W-9360 5' 1640#
W-9320 W-9361 6' 1968#
W-5933
Optional W-9362 7' 2296#
Information
W-9319 - 135 IS
610#/C
(assembly)
W-5918
End Cap
Electro Galvanized
W-5918
End Cap
Electro Galvanized
W-9318
135 degree OS
1-34" x 1-38" channel 10ga
(W-318 fabricated channel component)
W-9319-135 OS
Assembly
590#/C
W-9319 IS/OS
Standard Corner Inserts With Installed Nuts
W-5918
Electro Galvanized
Standard complete unit consists of:
Basic W-9318 IS/OS Standard Comer Inserts W-2-8-WS End Cap
Channel
Channel Nuts
W-5918
& Hardware
W-9319-90 IS
Fittings
615#/C
(Assembly)
Brackets
W-9318
Clamps
Fabricated Channel
Beam
Component
Bases
Post
W-9318-IS
6" Welded Stud Fabricated Channel
Caps
End
(4) Typ. Component
Clamps
Accessories
Electrical
W-6518
W-6518
Concrete
Inserts
Plastic Closure Strip
6" Welded Stud
Cushioned
Clamping
(4) Typ.
W-9318-90 OS
610#/C W-2-8-WS
Supports
Rooftop
Channel Nut
(Assembly) W-5918
4 total
Electro Galvanized
Specifications
End Cap
Material
W-9320
Springless Nut Platform
1.5#/C
Information
Design
OMEGA SERIES The Omega Series clamp assembly retains, guides, protects and
uniformly spaces line runs. Attached with two standard fasteners to any flat surface, providing
a savings in both space and cost.
THE CLAMP Available in steel (with electro-dichromate finish), and stainless steel.
THE CUSHION Manufactured from a thermoplastic elastomer, its built tough to withstand
the effects of most oils, chemicals and industrial cleaning compounds, in temperatures from
OMEGA SERIES -50F to 275F. Interlock edge ensures that the cushion remains in place.
(See Page 95)
Channel
(See Page 97) economical lightweight hanger for (See Page 97) clamps allow quick and easy
supporting tubing. The secure but corrosion resitant attachment of
non-tightening design allows for pipe, tube, and hose to Z-Strut
Channel Nuts
& Hardware
expansion, greatly reducing joint support channels. They offer
fractures a cost effective alternative to
metallic clamps.
Fittings
CUSH-A-STRIP is manufactured from a thermoplastic elastomer,
Cush-A-Strip is designed for use from -50F to 275F.
Brackets
Cush-A-Strip is designed for use with standard steel clamps ranging
from 14" tube to 6" pipe and is packaged in 20 Ft. rolls in an E-Z
dispenser box.
CUSH-A-STRIP
Clamps
The special locking lip edges ensure that Cush-A-Strip will remain in
Beam
(See Page 99)
place with a balanced grip.
Bases
Post
AIRSTRIP The AIRSTRIP is designed to dampen the noise
(See Page 98) and vibration that can occur between piping or duct
work and the supporting channel. Made from 64
Caps
End
durometer Santoprene, the AIRSTRIP is light
weight, dependable, and long-lasting.
Clamps
ALPHA SERIES ALPHA SERIES Designed for the tough jobs, the Alpha Series
Accessories
Electrical
(See Page 100) U-Bolt Assembly secures pipe runs to any flat surface. The cushion
design provides total load distribution, allowing the U-Bolt to become a
full contact hanger, eliminating knife-edge loading.
The U-Bolt traps and secures the cushion in place to prevent lateral
Concrete
Inserts
movement, while nylon insert locknuts provide a positive lock. Available
in electro-galvanized steel or 316 stainless steel.
Cushioned
The Cushion is a thermoplastic elastomer.
Clamping
CUSH-A-THERM SADDLE-UP QUICK-CLIP
(See Page 106 - 107) (See Page 104) (See Page 108)
Supports
Rooftop
Specifications
Material
ZSi-Foster offers flame retardant options for many of the clamping products.
They are available in two different types of cushion. The Flame Retardant/
High Hardness cushion is designed for applications such as wire and cable
insulation, electrical connectors, seals, gaskets and boots. The Halogen-Free/
Installation
Halogen Free
Wesanco Engineering Catalog 91
C ush -A-N ator
UL A
D
The Cush-A-Nator is designed to provide the user with a choice of the highest heat range
resistance of any cushion on the market or simply the advanced features of a superior design.
The Cush-A-Nator is designed and manufactured in Michigan.
A
Features
D D
B C
Pressure Control
A Thumb Drive
The Cush-A-Nator has the exclusive Thumb Drive that provides The Cush-A-Nator cushion has a built in squeeze control as part
the installer a gripping point to easily open the cushion with the help of the cushion design. The side opening and the squeeze control tab
of leverage tabs and a living hinge. Easy and effortlessly to install. provides evenly distributed pressure around the tube or pipe.
D
Complete Clamping Unit
B Self-Alignment
Cushion can be opened and placed over the pipe or tube and rotated The Cush-A-Nator is the only strut mounted cushion that is
into place while on the channel and automatically aligned with the mechanically connected to the supporting steel clamp because the
channel opening ready for clamping. bolt passes through the squeeze control tab forming the single unit
connection. This design helps prevent the cushion from excess
Installation examples shown on page 94 vibration by being attached directly to the clamp.
92 www.wesanco.com
C ush -A-N ator
Cush-A-Nator Cool Blue has service Cush-A-Nator standard has an operating range
Channel
temperatures of -65F to 340F (-53C to 170C). of -50F to 275F (-45C to 135C).
Channel Nuts
& Hardware
Cush-A-Nator Cool Blue - Tube Cush-A-Nator Standard - Tube
Part No. O.D. Tube Dimensions (inches) Part No. O.D. Tube Dimensions (inches)
Fittings
Size Size
Steel SS304 SS316 A B C D Steel SS304 SS316 A B C D
1 1
HT04 HT04SS HT04S6 4" 0.25 0.62 0.27 0.98 CN04 CN04SS CN04S6 4" 0.25 0.62 0.27 0.98
3 3
HT06 HT06SS HT06S6 8" 0.37 0.82 0.33 1.13 CN06 CN06SS CN06S6 8" 0.37 0.82 0.33 1.13
Brackets
1 1
HT08 HT08SS HT08S6 2" 0.50 0.94 0.40 1.34 CN08 CN08SS CN08S6 2" 0.50 0.94 0.40 1.34
5 5
HT10 HT10SS HT10S6 8" 0.62 1.06 0.46 1.54 CN10 CN10SS CN10S6 8" 0.62 1.06 0.46 1.54
3 3
HT12 HT12SS HT12S6 4" 0.75 1.20 0.52 1.68 CN12 CN12SS CN12S6 4" 0.75 1.20 0.52 1.68
Clamps
7 7
8" 0.87 1.31 0.58 1.82 8" 0.87 1.31 0.58 1.82
Beam
HT14 HT14SS HT14S6 CN14 CN14SS CN14S6
HT16 HT16SS HT16S6 1" 1.00 1.44 0.65 1.95 CN16 CN16SS CN16S6 1" 1.00 1.44 0.65 1.95
HT18 HT18SS HT18S6 11 8" 1.12 1.57 0.70 2.08 CN18 CN18SS CN18S6 11 8" 1.12 1.57 0.70 2.08
Bases
1
Post
HT20 HT20SS HT20S6 1 4" 1.25 1.70 0.77 2.21 CN20 CN20SS CN20S6 11 4" 1.25 1.70 0.77 2.21
HT22 HT22SS HT22S6 13 8" 1.37 1.82 0.83 2.34 CN22 CN22SS CN22S6 13 8" 1.37 1.82 0.83 2.34
11 2" 1.50 1.95 0.90 2.47 11 2" 1.50 1.95 0.90 2.47
Caps
HT24 HT24SS HT24S6 CN24 CN24SS CN24S6
End
5
HT26 HT26SS HT26S6 1 8" 1.62 2.07 0.96 2.60 CN26 CN26SS CN26S6 15 8" 1.62 2.07 0.96 2.60
HT28 HT28SS HT28S6 13 4" 1.75 2.20 1.02 2.73 CN28 CN28SS CN28S6 13 4" 1.75 2.20 1.02 2.73
Clamps
7
HT30 HT30SS HT30S6 1 8" 1.87 2.32 1.09 2.86 CN30 CN30SS CN30S6 17 8" 1.87 2.32 1.09 2.86
HT32 HT32SS HT32S6 2" 2.00 2.45 1.15 3.04 CN32 CN32SS CN32S6 2" 2.00 2.45 1.15 3.04
1 1
HT34 HT34SS HT34S6 2 8" 2.12 2.57 1.27 3.23 CN34 CN34SS CN34S6 2 8" 2.12 2.57 1.27 3.23
Accessories
Electrical
HT36 HT36SS HT36S6 21 4" 2.25 2.82 1.41 3.67 CN36 CN36SS CN36S6 21 4" 2.25 2.82 1.41 3.67
HT38 HT38SS HT38S6 23 8 " 2.37 2.82 1.41 3.67 CN38 CN38SS CN38S6 23 8 " 2.37 2.82 1.41 3.67
HT40 HT40SS HT40S6 21 2" 2.50 2.94 1.46 3.79 CN40 CN40SS CN40S6 21 2" 2.50 2.94 1.46 3.79
HT42 HT42SS HT42S6 25 8 " 2.62 3.07 1.53 3.92 CN42 CN42SS CN42S6 25 8 " 2.62 3.07 1.53 3.92
Concrete
Inserts
HT46 HT46SS HT46S6 27 8 " 2.87 3.32 1.66 4.17 CN46 CN46SS CN46S6 27 8 " 2.87 3.32 1.66 4.17
HT48 HT48SS HT48S6 3" 3.00 3.57 1.78 4.42 CN48 CN48SS CN48S6 3" 3.00 3.57 1.78 4.42
HT50 HT50SS HT50S6 31 8" 3.12 3.57 1.78 4.42 CN50 CN50SS CN50S6 31 8" 3.12 3.57 1.78 4.42
Cushioned
Clamping
1
HT56 HT56SS HT56S6 3 2" 3.50 3.95 1.97 4.79 CN56 CN56SS CN56S6 31 2" 3.50 3.95 1.97 4.79
HT64 HT64SS HT64S6 4" 4.00 4.45 2.28 5.11 CN64 CN64SS CN64S6 4" 4.00 4.45 2.28 5.11
HT66 HT66SS HT66S6 41 8" 4.12 4.57 2.34 5.54 CN66 CN66SS CN66S6
1
4 8" 4.12 4.57 2.34 5.54
HT72 HT72SS HT72S6 41 2" 4.50 4.95 2.53 5.92 41 2" 4.50 4.95 2.53 5.92
Supports
CN72 CN72SS CN72S6
Rooftop
Cush-A-Nator Cool Blue - Pipe Cush-A-Nator Standard - Pipe
Specifications
Material
Part No. Pipe Dimensions (inches) Part No. Pipe Dimensions (inches)
Size Size
Steel SS304 SS316 A B C D Steel SS304 SS316 A B C D
1 1
HT14P HT14PSS HT14PS6 2" 0.840 1.29 0.58 1.82 CN14P CN14PSS CN14PS6 2" 0.840 1.29 0.58 1.82
3 3
4" 1.050 1.57 0.70 2.08 CN17P CN17PSS CN17PS6 4" 1.050 1.57 0.70 2.08
Information
HT21P HT21PSS HT21PS6 1" 1.315 1.76 0.81 2.34 CN21P CN21PSS CN21PS6 1" 1.315 1.76 0.81 2.34
HT30P HT30PSS HT30PS6 11 2" 1.900 2.32 1.09 2.86 CN30P CN30PSS CN30PS6 11 2" 1.900 2.32 1.09 2.86
HT38P HT38PSS HT38PS6 2" 2.375 2.82 1.41 3.67 CN38P CN38PSS CN38PS6 2" 2.375 2.82 1.41 3.67
1 1
2 2" 2.875 3.32 1.66 4.17 2 2" 2.875 3.32 1.66 4.17
Installation
HT64P HT64PSS HT64PS6 31 2" 4.000 4.45 2.28 5.11 CN64P CN64PSS CN64PS6 31 2" 4.000 4.45 2.28 5.11
HT72P HT72PSS HT72PS6 4" 4.500 4.95 2.53 5.92 CN72P CN72PSS CN72PS6 4" 4.500 4.95 2.53 5.92
Index
Contact Factory for Additional Sizes Contact Factory for Additional Sizes
Wesanco Engineering Catalog 93
C ush -A-N ator
Step 3: Rotated into place while on the channel and the Step 3: Add Pipe Clamps and tighten the assembly.
Self-Alignment tab automatically aligns with the channel
opening ready for clamping.
94 www.wesanco.com
O mega S eries
Channel
Gold Electro-Galvanized Steel Stainless Steel
UL
Channel Nuts
& Hardware
UL Standard 2043, Fourth Edition, dated
October 2, 2013.
"Fire Test for Heat and Visible Smoke
Release for Discrete Products and Their
Accessories Installed in Air-Handling Spaces".
Fittings
The Omega Series clamp assembly Copper Copper Dimensions (inches)
Stainless Pipe Hanging
Steel & Steel Water
retains, guides, protects and uniformly Steel Size Design
Part No. Tubing Pipe A B C D E F
Brackets
spaces line runs. Attached with two standard Part No.
(Nom.)
(Nom.) Load
O.D.
fasteners to any flat surface, the Omega 004M007 004MS007 1
4" - - 0.25 0.48 0.60 0.22 0.26 0.78 50
Series clamp eliminates the use of special 006M008 006MS008 3
8" 1
4" - 0.37 0.62 0.66 0.31 0.26 0.81 50
channels, providing a savings in both space 1
2" 3
8" 1
4" 0.50 0.81 0.83 0.40 0.26 0.98 50
Clamps
008M011 008MS011
Beam
and cost. They go up fast, lines are rigid and 010M013 010MS013 5
8" 1
2" 3
8" 0.62 0.93 0.85 0.46 0.26 0.98 50
look neat. 012M015 012MS015 3
4" 5
8" - 0.75 1.02 0.90 0.50 0.26 0.98 50
7 3 1
014M017 014MS017 8" 4" 2" 0.87 1.12 1.03 0.53 0.26 0.98 50
Bases
THE CLAMP Steel with electro-
Post
016M019 016MS019 1" - - 1.00 1.24 1.04 0.59 0.26 0.98 50
dichromate finish, or stainless steel 3
018M020 018MS020 - - 4" 1.05 1.40 1.11 0.70 0.26 0.98 50
type 304.
Caps
018M021 018MS021 1-1 8" 1" - 1.12 1.40 1.17 0.70 0.26 0.98 50
End
THE CUSHION Manufactured from a 020M024 020MS024 1-1 4" - - 1.25 1.60 1.20 0.77 0.26 1.56 50
thermoplastic elastomer, its built tough to 021M026 021MS026 - - 1" 1.31 1.71 1.28 0.81 0.26 1.56 50
Clamps
withstand the effects of most oils, chemicals 022M026 022MS026 1-3 8" 1-1 4" - 1.37 1.71 1.28 0.83 0.26 1.56 50
and industrial cleaning compounds, in 024M028 024MS028 1-1 2" - - 1.50 1.85 1.36 0.90 0.26 1.56 200
temperatures from -50F to 275F. Interlock 026M030 026MS030 1- 5 8" 1-1 2" - 1.62 1.98 1.43 0.96 0.26 1.56 200
Accessories
Electrical
edge ensures that the cushion remains in 027M032 027MS032 - - 1-1 4" 1.66 2.12 1.55 0.99 0.34 1.56 400
place. 028M032 028MS032 1-3 4" - - 1.75 2.12 1.55 1.02 0.34 1.56 400
030M034 030MS034 1-7 8" - 1-1 2" 1.87 2.25 1.64 1.09 0.34 1.56 400
032M036 032MS036 2" - - 2.00 2.38 1.69 1.15 0.34 1.56 400
2-1 8" - -
Concrete
034M040 034MS040 2.12 2.62 1.86 1.27 0.34 1.56 400
Inserts
038M044 038MS044 2-3 8" - 2" 2.37 2.88 1.94 1.41 0.34 1.56 400
040M046 040MS046 2-1 2" - - 2.50 3.00 2.00 1.47 0.34 1.56 400
042M048 042MS048 2- 5 8" 2-1 2" - 2.62 3.13 2.07 1.53 0.34 1.56 400
Cushioned
Clamping
046M052 046MS052 2-7 8" - 2-1 2" 2.87 3.38 2.19 1.65 0.34 1.56 400
050M056 050MS056 3-1 8" 3" - 3.12 3.68 2.32 1.78 0.34 1.56 400
056M062 056MS062 3-1 2" - 3" 3.50 4.06 2.50 1.97 0.34 1.56 400
F
058M064 058MS064 3- 5 8" 3-1 2" - 3.62 4.19 2.57 2.03 0.34 1.56 700
Supports
Rooftop
A 064M072 064MS072 4" - 3-1 2" 4.00 4.68 2.82 2.28 0.34 1.56 700
066M074 066MS074 4-1 8" 4" - 4.12 4.84 3.05 2.34 0.43 1.56 800
072M080 072MS080 4-1 2" - 4" 4.50 5.22 3.24 2.53 0.43 1.56 800
B
082M090 082MS090 5-1 8" 5" - 5.12 5.82 3.55 2.84 0.43 1.56 800
Specifications
E
D 089M096 089MS096 - - 5" 5.56 6.31 4.00 3.06 0.56 1.56 1,200 Material
098M106 098MS106 6-1 8" 6" - 6.12 6.90 4.31 3.34 0.56 1.56 1,200
C 106M114 106MS114 - - 6" 6.62 7.39 4.56 3.58 0.56 1.56 1,200
Cushions Example
Information
NH
Flame Retardant 004M007NH (STEEL)
Halogen Free 004MS007NH (STAINLESS STEEL)
Index
Strut Mounted
The Cush-A-Claw Grabs on to your Tube, Pipe, or Hose and holds O.D. Tube Size EMTS Conduit Sizes
it in place. The unique one piece patent pending design allows
for quick, simple, and easy installation. It will not rust because it's Strut Surface Size Strut Surface Size
Mount Mount Mount Mount
molded from the same choice TPE Material of some of our other
Part # Part #. O.D. In. Part # Part #. O.D. In.
products that you've come to know and trust. 1 1
CL-04 CLS-04 4" 0.250 EMT-1/2 EMTS-1/2 2" 0.706
Easy Snap-in Installation of Tube, Pipe, or Hose CL-06 CLS-06
3
8" 0.375 EMT-3/4 EMTS-3/4
3
4" 0.922
Sure Grip Strut Base easily rotates into strut CL-08 CLS-08
1
2" 0.500 EMT-1 EMTS-1 1" 1.163
Will not Rust CL-10 CLS-10
5
8" 0.625
Non Conducting CL-12 CLS-12
3
4" 0.750
Saves Time and Money CL-14 CLS-14
7
8" 0.875 Size
Range
Temp Range: -50 to 275 F CL-18 CLS-18 11 8" 1.125
Works Great Indoors or Outdoors
Six Sizes of Tube and Three Sizes of EMT 75 Lbs . Load
Designed for Light Duty Loads and Applications (safety Factor 3)
Prevents Galvanic Corrosion of Dissimilar Metals
An Excellent Alternative to Steel, Stainless Steel,
or Galvanized Clamps.
CUSH-A-CLIP
Channel
Manufactured from polyamide alloy
Channel Nuts
U.L. Rated
& Hardware
3 1
Sizes from 8" to 1 8"
A SIMPLE, ECONOMICAL,
LIGHTWEIGHT HANGER FOR One piece design makes installation a snap.
SUPPORTING TUBING No nuts to tighten, no parts to lose.
Fittings
Temperatures from -40F to 275F
Secure but non-tightening design allows for
expansion, greatly reducing joint fractures
Brackets
Tube Sizes
Clamps
Part Only
Beam
Number
O.D. In.
Size
Bases
3
RPC-3/8 8" 0.375"
Post
1
RPC-1/2 2" 0.500"
5
RPC-5/8 8" 0.625"
Caps
End
3
RPC-3/4 4" 0.750"
7
RPC-7/8 8" 0.875"
Clamps
1
RPC-1-1/8 1- 8" 1.125"
Accessories
Electrical
FEATURES
D 1716"
Ten sizes of tube,
five sizes of pipe
Concrete
C
Inserts
Diameters from .25" to 1.31"
B ADVANTAGES
Reduces inventory SKUs
Cushioned
A
Clamping
Simplifies take-offs and
requirements on projects using
both tube and pipe sizes
Easy installation, Non conducting
Supports
Rooftop
V-Pad Permissible outdoors
Temp. range: -40F to +380F
Patented Product
No galvanic reaction, Will not rust
Specifications
Part O.D. Pipe Metric Diameters BENEFITS Material
No. Tube Sizes Sizes Sizes (in) Lowers overall inventory costs
1 3 1 1
CG-10 4" 8" 2" 4" 6mm 14mm 0.25 0.54 Works with screw or nut driver
5 3 7 3
CG-20 8" 4" 8" 8" 1 2" 15mm 22mm 0.62 0.87 Resists vibration
7
CG-30 8" 1" 1-1 8" 3
4" 22mm 28mm 0.87 1.12 Use in place of steel clamps with
Information
3
CG-40 4" 2-11 16 " 1-15 16 " 7
16 " 5
16 " 1
4"-20 x 2"
The AIRSTRIP is designed to dampen the noise and vibration Max. Load Lbs.
that can occur between piping or duct work and the supporting Length
Part No. per Lineal In.
channel. Made from 64 Durometer Santoprene, the AIRSTRIP
Lbs. (kg/25.4mm) Ft. (m)
is light weight, dependable, and long-lasting.
AS1 40 18.1 10 3.05
1.65
0.2598
0.3
1.085
Installs simply by pushing into place To remove, squeeze the tabs at the end and push up
98 www.wesanco.com
C ush -A-S trip
Channel
Manufactured from a thermoplastic elastomer, Cush-A-Strip is
designed for use from -50F to 275F.
Channel Nuts
& Hardware
Easy Stocking Packaged in 20 foot rolls in an E-Z dispenser
box for convenience in handling and storage. Cush-A-Strip
roll part number is S-716
Fittings
1
Easy Measuring Marked in 4" increments for fast measuring
and cutting, while eliminating waste.
Brackets
Lock-lip edges ensure that Cush-A-Strip will remain in place
with a balanced grip.
Clamps
Beam
Clamps ordered separately. They are available with a standard
bolt and nylon lock nut in steel (electro-dichromate), and
1
stainless steel, in sizes ranging from 4" tube to 6" pipe.
Bases
Post
Cush-A-Strip Cutting Guide
Caps
End
Clamp Part No. Dimensions (Inches)
Gold Stainless Clamp Tube Pipe Size Cutting
Clamps
Plated Steel Type Size Size (Nom.) Schedule
(1) Cut appropriate length strip Steel 304 O.D. O.D.
using the cutting schedule 1
2" 1
4" 7
8
N008C NS008
shown on right.
Accessories
5 3
N010C NS010 8" 8" 1-1 8
Electrical
3 1 1
N012C NS012 4" 2" 4" 1-1 2
7 5 3
N014C NS014 8" 8" 8" 2
3
N016C NS016 1" 4" 2-1 4
N018C NS018 1-1 8" 7
8" 1
2" 3
Concrete
Inserts
(2) Place the pipe on the N020C NS020 1-1 4" 1" 3
4" 3-1 4
Cush-A-Strip N022C NS022 1-3 8" 1-1 8" 3- 5 8
N024C NS024 1-1 2" 1-3 16" 3-7 8
Cushioned
N024C NS024 1-1 2" 1-1 4" 1" 4
Clamping
N026C NS026 1- 5 8" 1-3 8" 4-1 2
(3) Insert the clamps in 1-3 4" 1-1 2" 4-7 8
N028C NS028
the strut N030C CS030 1-7 8" 1- 5 8" 1-1 4" 5-1 4
2" 1-3 4" 5-1 2
Supports
N032C CS032
Rooftop
N034C CS034 2-1 8" 1-7 8" 1-1 2" 6
(4) Tighten the clamps. N036C CS036 2-1 4" 2" 6-3 8
N038C CS038 2-3 8" 2-1 8" 6-3 4
Specifications
N040C CS040 2-1 2" 2-1 4" 7-1 4
Material
N042C CS042 2- 5 8" 2-3 8" 2" 7-1 2
N044C CS044 2-3 4" 2-1 2" 8
N048C CS048 3" 2-3 4" 8-3 4
N050C CS050 3-1 8" 2-7 8" 2-1 2" 9-1 4
Lock-lip Edge 3-1 4" 3" 9-1 2
Information
N054C CS054
Design
Designed for the tough jobs, the Alpha Series U-Bolt Assembly secures pipe runs to any flat
surface. The cushion design provides total load distribution, allowing the U-Bolt to become a full
contact hanger, eliminating knife-edge loading. The U-Bolt traps and secures the cushion in place
to prevent lateral movement, while nylon insert locknuts provide a positive lock.
Alpha Series U-Bolt Assembly conforms to 30
MIL-S-901D for shock testing. .017
B
A
30
.017
B
A
E
E D
D G
G
H F
C C
H F
1/2" thru 6" assembly. 8" thru 12" assembly Two piece cushion design
Channel
Channel Nuts
& Hardware
Fittings
The hinged cushion allows easy installation of the wire, but the
components will not get separated and lost or broken.
Brackets
Dimensions (Inches) Total Assy.
Part No.
Hole Dia. A R Height - H
006CC018 3
8 1.12 0.56 1.82
Clamps
Beam
008CC018 1
2 1.12 0.56 1.82
Replaces Porcelain and Maple Cable Clamp. Assembly consists
010CC018 5
8 1.12 0.56 1.82
of thermoplastic elastomer cushion with plated or stainless steel
012CC026 3
4 1.62 0.81 2.34
Bases
clamp. Plated steel and stainless are both supplied with Silicon
Post
014CC026 7
8 1.62 0.81 2.34
Bronze bolt and nut.
016CC026 1 1.62 0.81 2.34
Non-breakable material
Caps
018CC026 1-1 8 1.62 0.81 2.34
End
Chemical and UV resistant 020CC034 1-1 4 2.12 1.06 2.86
022CC034 1-3 8 2.12 1.06 2.86
Clamps
U.L. Listed - Burning stops within 10 seconds after two 024CC034 1-1 2 2.12 1.06 2.86
applications of ten seconds each of a flame to a test bar with 026CC034 1- 5 8 2.12 1.06 2.86
no flaming drips. 028CC042 1-3 4 2.62 1.31 3.50
Accessories
1-7 8 2.62 1.31 3.50
Electrical
Plated Steel, or Stainless steel clamps 030CC042
032CC042 2 2.62 1.31 3.50
Tapered flange to protect cable 034CC042 2-1 8 2.62 1.31 3.50
Dielectric strength 640 volts per mil 036CC050 2-1 4 3.12 1.56 4.05
2-3 8 3.12 1.56 4.05
Concrete
038CC050
Inserts
One piece cushion design, available with Flame retardant /
040CC050 2-1 2 3.12 1.56 4.05
Halogen Free cushions
042CC050 2- 5 8 3.12 1.56 4.05
Silicon Bronze Hardware used to Breakup the Magnetic field 044CC058 2-3 4 3.62 1.81 4.75
Cushioned
Clamping
around the Cable at the Clamping Location. 046CC058 2-7 8 3.62 1.81 4.75
048CC058 3 3.62 1.81 4.75
050CC058 3-1 8 3.62 1.81 4.75
052CC066 3-1 4 4.12 2.06 5.125
Supports
.25"
Rooftop
054CC066 3-3 8 4.12 2.06 5.125
056CC066 3-1 2 4.12 2.06 5.125
058CC066 3- 5 8 4.12 2.06 5.125
060CC074 3-3 4 4.62 2.31 5.54
Specifications
R Size
062CC074 3-7 8 4.62 2.31 5.54 Material
064CC074 4 4.62 2.31 5.54
H
066CC074 4-1 8 4.62 2.31 5.54
068CC080 4-1 4 5.00 2.50 5.92
R 070CC080 4-3 8 5.00 2.50 5.92
Information
Design
STANDARD SERIES
Assembly Types
Assembly Type Z
Steel w/Aluminum Cushion
- Strut Mounted
Channel
STANDARD SERIES COVER PLATE STANDARD SERIES SAFETY PLATE
SCP1 Use with Group S1 SP1 Use with Group S1
SCP2 Use with Group S2 SP2 Use with Group S2
Use with Group S3 Use with Group S3
Channel Nuts
SCP3 SP3
& Hardware
SCP4 Use with Group S4 SP4 Use with Group S4
SCP5 Use with Group S5 SP5 Use with Group S5
SCP6 Use with Group S6 SP6 Use with Group S6
SCP7 Use with Group S7
HEX BOLT STANDARD SERIES CAP SCREW
Fittings
(Two required per assembly) (Two required per assembly)
SHB1 Use with Group S1 SC-1 Use with Group S1
SHB2 Use with Group S2 SC-2 Use with Group S2
SHB3 Use with Group S3 SC-3 Use with Group S3
Brackets
SHB4 Use with Group S4 SC-4 Use with Group S4
SHB5 Use with Group S5 SC-5 Use with Group S5
SHB6 Use with Group S6 SC-6 Use with Group S6
SHB7 Use with Group S7
Clamps
Beam
STACKING BOLTS STRUT NUT - For connection to WesancoChannel
(Two required per assembly) (Two required per assembly)
SB1 Use with Group S1 ZSA1-8 Use with Groups S1-S8
Bases
SB2 Use with Group S2
Post
SB3 Use with Group S3
SB4 Use with Group S4
Use with Group S5
Caps
SB5
End
SB6 Use with Group S6
STANDARD SERIES WELD PLATE Wesanco Channel
Clamps
5 5
SWP1 Use with Group S1 W-200, W-210 1 8" x 1 8"
5 13
SWP2 Use with Group S2 W-400, W-500 1 8" x 16"
5
SWP3 Use with Group S3 W-800 1 8" x 1"
Accessories
Electrical
5 7
SWP4 Use with Group S4 W-900 1 8" x 8"
SWP5 Use with Group S5
Use with Group S6
See Pages 8 - 33
SWP6 for channel information
SWP7 Use with Group S7
Concrete
Inserts
ORDERING EXAMPLE
Cushioned
(2) SHB1 Hex Bolts
Clamping
S1004Z
Assembly Includes SCP1 Cover Plate
Quantity Part No. Description
Supports
Rooftop
2 Each SHB1 Hex Bolts
1 Each SCP1 Cover Plate
1 set S1004C Cushions
Specifications
Cushions
2 Each ZSA-1 Channel Nuts S1004C Material
Wesanco Channel
(not included)
Index
INSULATION SADDLE
The Saddle-Up Pipe Insulation Saddle is a formed metal
shield designed to allow insulated refrigeration
pipe or tubing to pass through the
support without need to
compromise the vapor
barrier and protects
from crushing or
damage at hanger and
support locations. Made from 20 gage electro-galvanized steel
the ribbed design along its 12 inch length offers the superior
support needed to spread out loading on insulation which reduces
the potential for internal cavity creation between the pipe and
insulation. The Z-Strut mounting option provides a time tested Assembly Side View
secure and safe attachment method so there is no need for other
tie downs to the support.
OTHER FEATURES INCLUDE:
Shipped with all necessary hardware to attach to Z-Strut or any Channel Z-STRUT
other industry standard 158" wide strut channel. Nut Channel
12 1/4 X 3/4 Flat Head
Features flared edges to protect pipe insulation jacketing.
Machine Screw
Each Saddle individually marked with part number B
Counter Sunk attachment Hole and Flat Head Machine Screw A
prevent possible damage to insulation.
Electro-Galvanized Steel provides excellent rust protection and
has no exposed fabricated edges.
Assembly End View
1 3
2" 4" 1" 1 1 2"
Dimensions (Inches)
Insulation Insulation Insulation Insulation
Part B A OD Tube OD With OD Tube OD With OD Tube OD With OD Tube OD With
Number Width Radius Size Insulation Size Insulation Size Insulation Size Insulation
3
3 8 13 8
SD150 11 2 4 1
2 11 2
5 3
8 15 8 8 17 8
3 1
SD200 2 1 4 13 4 2 2
7
8 17 8
11 8 21 8 5
8 21 8 3
8 23 8
SD250 1
2 2 11 4 13 8 23 8 3
4 21 4 1
2 21 2
7
8 23 8
15 8 25 8 11 8 25 8 5
8 25 8
SD300 3 11 2 13 8 27 8 3
4 23 4
7
8 27 8
21 8 31 8 15 8 31 8 11 8 31 8 3
8 33 8
SD350 31 2 13 4
23 8 33 8 13 8 33 8 1
2 31 2
25 8 35 8 21 8 35 8 15 8 35 8 5
8 35 8
23 8 37 8 3
4 33 4
SD450 41 2 21 4 7
8 37 8
31 8 41 8 25 8 41 8 21 8 41 8 11 8 41 8
23 8 43 8 13 8 43 8
35 8 45 8 31 8 45 8 25 8 45 8 15 8 45 8
3
SD550 1
5 2 2 4 41 8 51 8 35 8 51 8 31 8 51 8 21 8 51 8
23 8 53 8
41 8 55 8 35 8 55 8 25 8 55 8
SD650 61 2 31 4
41 8 61 8 31 8 61 8
104 www.wesanco.com
S nap -A-S addle
Channel
pipes to support channel, with one step, tool-free installation.
Channel Nuts
& Hardware
Fittings
Brackets
Temp Range: -50 to 275F (-46 to 135 C)
Snaps easily into
Available in both black and white
Clamps
channel
Beam
UL94-HB1 Rated TPV Material
Made in USA
Bases
Post
Easy Installation
Standard 12" lengths. Special lengths
Caps
End
Size available upon request
Clamps
Inside
Black White Opening
SB225 SW225 21 4
Accessories
Electrical
SB325 SW325 31 4
SB425 SW425 41 4
SB525 SW525 51 4
12"
Concrete
SB625 SW625 61 4
Inserts
SB825 SW825 85 8
Cushioned
Clamping
Supports
Rooftop
Snap-A-Saddle Size Guide - Copper Tubing Snap-A-Saddle Size Guide - Schedule 40/80 Pipe
Tubing Insulation Thickness Pipe Insulation Thickness
Specifications
1 3
Size 2" 4" 1" 1 1 2" 2" Size 1
2" 3
4" 1" 1 1 2" 2" Material
1 1
4 4
S*225
3
8 S*225 3
8
1 1 S*225 S*325 S*425 S*525
2 2
5 S*225 S*325 S*425 S*525 3
8 4
S*325
Information
3 1
4
Design
S*425
2-1 2 3
S*425 S*525 S*625 S*525 S*625 S*825
3 3-1 2 S*825
S*525 S*825 S*625
3-1 2 4 S*625 S*825
S*525 S*625 S*825
4 S*625 * Add "B" for Black or "W" for White
Index
Nominal 12" Nominal 34" Nominal 1" Nominal 1-1/2" Nominal 2"
Dimensions (Inches)
Wall Thickness Wall Thickness Wall Thickness Wall Thickness Wall Thickness
Hole Copper Pipe Part Cushion Part Cushion Part Cushion Part Cushion Part Cushion
IPS Len.
Size I.D. O.D. No. O.D. No. O.D. No. O.D. No. O.D. No. O.D.
1
4 - 1
4 - 2.953" UX1412 11 4 (1.250") UX1434 13 4 (1.750") UX1410 21 4 (2.250")
3
8 1
4 3
8 - 2.953" UX3812 13 8 (1.375") UX3834 17 8 (1.875") UX3810 23 8 (2.375") UX3815 33 8 (3.375")
1
2 3
8 1
2 1
4 2.953" UX1212 11 2 (1.500") UX1234 2 (2.000") UX1210 21 2 (2.500") UX1215 31 2 (3.500")
5
8 1
2 5
8 3
8 2.953" UX5812 5
1 8 (1.625") UX5834 1
2 8 (2.125") UX5810 5
2 8 (2.625") UX5815 35 8(3.625") UX5820 45 8 (4.625")
3
4 5
8 3
4 - 2.953" UX3412 13 4 (1.750") UX3434 21 4 (2.250") UX3410 23 4 (2.750") UX3415 33 4 (3.750") UX3420 43 4 (4.750")
7
7
8 3
4 7
8 1
2 2.953" UX7812 7
1 8 (1.875") UX7834 3
2 8 (2.375") UX7810 7
2 8(2.875") UX7815 3 8 (3.875") UX7820 47 8 (4.875")
1
1
1- 8 1 1
1 8 3
4 2.953" UX11812 1
2 8 (2.125") UX11834 5
2 8 (2.625") UX11810 1
3 8 (3.125") UX11815 4 8 (4.125") UX11820 51 8 (5.125")
3
3
1- 8 1
1 4 3
1 8 1 2.953" 3
UX13812 2 8 (2.375") UX13834 7
2 8 (2.875") UX13810 3
3 8 (3.375") UX13815 4 8 (4.375") UX13820 53 8 (5.375")
1- 5 8 11 2 15 8 11 4 2.953" UX15812 25 8 (2.625") UX15834 31 8 (3.125") UX15810 35 8 (3.625") UX15815 45 8 (4.625") UX15820 55 8 (5.625")
7
7
1- 8 7
1 8 2.953" UX17812 7 3
2 8 (2.875") UX17834 3 8 (3.375") UX17810 7
3 8 (3.875") UX17815 4 8 (4.875") UX17820 57 8 (5.875")
1
1
2- 8 2 1
2 8 - 2.953" UX21812 1 5
3 8 (3.125") UX21834 3 8 (3.625") UX21810 1
4 8 (4.125") UX21815 5 8 (5.125") UX21820 61 8 (6.125")
3
3
2- 8 1
2 4 3
2 8 2 3
2.953" UX23812 3 8 (3.375") UX23834 7
3 8 (3.875") UX23810 3
4 8 (4.375") UX23815 5 8 (5.375") UX23820 63 8 (6.375")
2- 5 8 21 2 25 8 - 3.937" UX25812 35 8 (3.625") UX25834 41 8 (4.125") UX25810 45 8 (4.625") UX25815 55 8 (5.625") UX25820 65 8 (6.625")
7
7
2- 8 7
2 8 1 7 3
2 2 3.937" UX27812 3 8 (3.875") UX27834 4 8 (4.375") UX27810 7
4 8 (4.875") UX27815 5 8 (5.875") UX27820 67 8 (6.875")
1
1
3- 8 3 1
3 8 - 3.937" UX31812 1
4 8 (4.125") UX31834 5
4 8 (4.625") UX31810 1
5 8 (5.125") UX31815 6 8 (6.125") UX31820 71 8 (7.125")
1 1
1
3- 2 1
3 2 3 3.937" UX31212 4 2 (4.500") UX31234 5 (5.000") UX31210 1
5 2 (5.500") UX31215 6 2(6.500") UX31220 71 2 (7.500")
5 5
5
3- 8 1
3 2 5
3 8 - 5
3.937" UX35812 4 8 (4.625") UX35834 1
5 8 (5.125") UX35810 5 8 (5.625") UX35815 6 8 (6.625") UX35820 75 8 (7.625")
4-1 8 4 4-1 8 31 2 3.937" UX41812 51 8 (5.125") UX41834 55 8 (5.625") UX41810 61 8 (6.125") UX41815 71 8 (7.125") UX41820 81 8 (8.125")
106 www.wesanco.com
C ush -A-T herm
Channel
INSTALLATION IS AS EASY AS 1-2-3!
Channel Nuts
& Hardware
Fittings
Brackets
Clamps
Beam
1. Insulation slidesover pipes. 2 Put in place and glue to insulation. 3. Wrapand seal withProTape.
Self adhesive surfaces provide seal.
Bases
Post
Cush-A-Therm v.s. Plastic Alternative
Caps
End
Insulation Glued to Cush-A-Therm
which Avoids Air Space and Loss of Insulation
Air Space (loss of insulation)
Clamps
Pipe Insulation Pipe Insulation
Accessories
Electrical
Concrete
Inserts
Pipe Insulation
Pipe Insulation
Cush-A-Therm Plastic Connector Plastic Connector is
Only Insulation Contacts Pipe
Cushioned
Clamping
Thermal Conductor
no Thermal Conductor
ASHRAE Insulation Recommendations
Supports
Cush-A-Therm is designed to meet the ASHRAE recommendations for insulation for mechanical systems which indicate that insulated pipe
Rooftop
hangers should provide the following:
1. Complete sealing of pipe against water vapor ingress
Specifications
2. No energy transfer of cold to supporting clamp to prevent condensation of water and possible growth of mold. If the support incasing
Material
the insulation is in contact with the pipe or tube and supported by a metallic clamp, which is not protected by insulation, below
ambient temperatures will be transfer to the clamp causing energy transfer and condensation.
3. No interruption of the insulation envelope
4. Limit or avoid compression at support location
Information
Design
ASHRAE Section 23.13-23.14 further states when the goal is avoiding compression of low-compressive-strength insulation products, it is
recommended to use high-strength insulation inserts made of a product that offers the desired compressive strength and other necessary
performance properties. Other higher-strength materials that are not thermal insulation material and interrupt the insulation envelope, or
Installation
do not allow complete sealing of an insulation system against water vapor ingress are not recommended for supporting insulated piping on
pipe hangers. Note that wood blocks have poor thermal conductivity and are not recommended, especially for cold pipe systems.
Insulated cold piping should receive special attention when exposed to ambient or unconditioned air. The Cush-A-Therm is a product
that seals out air, and insulates the pipe/tube from the supporting clamp, and is therefore in compliance with the 2013 ASHRAE insulation
Index
recommendations.
Wesanco Engineering Catalog 107
Q uick -C lip , C ush -A-C lick
Size
CUSH-A-CLICK Size
108 www.wesanco.com
C ush -A-B lock
R ooftop S upports
CUSH-A-BLOCK SUPPORTS
Channel
Channel Nuts
& Hardware
Fittings
Brackets
Patent Pending
Clamps
Cush-A-Block features:
Beam
Solar Racking
100% Recycled Rubber
Pipe & Conduit supports
Bases
LEED Certifiable
Post
HVAC, Duct, Cable Tray supports
Meets the Buy America Act and
American Reinvestment Recovery Act (A.R.R.A.) Air Conditioning supports
Caps
End
Independent Laboratory Tested to the following Roof Walkway supports
- ASTM D575 Method B Modified, Compression/Deflection
Clamps
The channel for Cush-A-Block support assemblies includes a
- ASTM D1171 Modified Ozone Resistance
variety of options. The strut can be made in special lengths,
- Freeze/Thaw Environmental Simulation
finishes, and alloys including Aluminum, Stainless Steel both 304
Resistance to Freeze and Thaw
Accessories
& 316, PVC coated, Powder coated, Zinc Trivalent Chromium,
Electrical
All 4 Corners coated with reflective safety orange for visibility Pre-Galvanized and Hot Dipped Galvanized.
Dampens Vibrations
Compatible with most rooftop materials
Concrete
Inserts
Cushioned
Clamping
Supports
Rooftop
All Cush-A-Block products made
with 1-58" and higher channel
Specifications
is equipped with (2) 14" x 1-14" hex Material
head cap screws, washers and nuts. Information
Design
Installation
Index
MA
IN DE
US
A
658"
5"
CBS-Mini Series
Part No. Uniform Load Capacity (Lbs) *
CBS-Mini 400 *
* This load is only for the capacity of the components in this assembly. Please consult
roofing manufacturer or engineer for roof load capacity
CUSH-A-BLOCK SUPPORTS
CBS BASE SERIES
4"
CBS-Base Series Cu
sh
-A
-B
Part No. Uniform Load Capacity (Lbs) * ww loc
w. k
zs
i-in
CBS 2,500 * c.c
om
* This load is only for the capacity of the components in this assembly. Please consult 107 8"
roofing manufacturer or engineer for roof load capacity
5"
110 www.wesanco.com
C ush -A-B lock
R ooftop S upports
CUSH-A-BLOCK SUPPORTS
Channel
CBS SERIES W/METAL CHANNEL
Standard strut mount pipe clamps are used to secure the pipes.
Channel Nuts
& Hardware
Note: Roof supports come pre-assembled
The CBS Series provides a longer mounting surface with strut
lengths up to 4638"
Fittings
Cu
sh
Brackets
-A
-B
loc
ZS
i-F k
Str
os
ter
.co ut L
m
eng
Cu
sh
-A
-B
th
ZS loc
i-F k
os
ter
Clamps
.co
Beam
m
Cu
sh
Tot -A
-B
al L ZS loc
i-F k
eng
os
ter
.co
th
m
Bases
Post
Cu
sh
-A
-B
ZS loc
i-F k
os
ter
.co
m
Caps
End
CBS2RD shown Width
with two bases
Clamps
CBS-Support With 1316" Pre-Galv. Steel Channel
Part No. of Strut Total Uniform Load
Accessories
Electrical
No. Bases Length Length Capacity (Lbs) *
Concrete
Cu
Inserts
sh
-A
-B
ww loc
w.
Z
k
Si-
Fo
ste
r.c CBS3S 3 34.375" 36" 7,500 *
10 8"7 o m
Cushioned
5"
Clamping
CBS4S 4 46.375" 48" 10,000 *
Supports
9516"
Rooftop
558" 2 22.375" 24" 5,000 *
Cu
CBS2D
sh
-A
-B
ww loc
k
Specifications
w.Z
Si-
Fo
ste
r.c
CBS3D 3 34.375" 36" 7,500 *
om
Material
10 8" 7
9516"
6716" CBS2RD 2 22.375" 24" 5,000 *
Cu
sh
-A
Installation
-B
ww loc CBS3RD 3 34.375" 36" 7,500 *
w.
Z Si-
k
Fo
ste
r.c
o m
1078"
5" CBS4RD 4 46.375" 48" 10,000 *
Index
* This load is only for the capacity of the components in this assembly. Please consult roofing manufacturer or engineer for roof load capacity
558"
Cu
Strut Length
sh
-A
-B
ww loc
w.
Z Si-
k
Fo
ste
r.c
o m
Cu
Total sh
-A
-B
Length ww
w.
Z Si-
loc
k
Fo
ste
r.c
o m
CUSH-A-BLOCK SUPPORTS
CBS-PRB SERIES, WITH PIPE ROLLER
Roller
Note: Roof supports come pre-assembled Size
ww Base
CBS4PRB 8" to 10" 10- 5 16" 8-1 4" 24" 2 2,500 * Length
* This load is only for the capacity of the components in this assembly. Width
Please consult roofing manufacturer or engineer for roof load capacity
112 www.wesanco.com
C ush -A-B lock
R ooftop S upports
CUSH-A-BLOCK SUPPORTS
Channel
CBS-CE SERIES WITH RAISED CHANNEL
Channel Nuts
Standard strut mount pipe clamps are used to secure the pipes.
& Hardware
Note: Roof supports come pre-assembled
Fittings
Brackets
CBS16EX
Clamps
CBS8EX,
Beam
CBS12EX
Bases
Post
Caps
9516"
End
Height
Clamps
13
16" Strut
Accessories
24"
Electrical
Height
Cu
sh
-A
ww
-B
loc 158"
w.
Z Si k Strut
Concrete
-F
os
Inserts
ter
.co
m
Cu
CBS8EX, 10 8"
7 sh
-A
ww -B
w. loc
Z Si- k
CBS12EX 5"
Fo
ste
r.c
Cushioned
o m
Clamping
CBS16EX
Cu
sh
-A
-B
26" ww
w.
Z Si-
Fo
loc
k
ste
r.c
o m
Supports
Rooftop
CBS-EX-Extension Series Support With
5"
Threaded Rod Extension and Channel
Specifications
Uniform Load
Part No. Height
Capacity (Lbs) * Material
CBS8EX 8" 1,000 *
CBS12EX 12" 1,000 *
* This load is only for the capacity of the components in this assembly. Please consult
Design
10" Strut
Width
k
oc
Bl
A-
s h-
Cu
m
r.co
ste
Fo
Si-
w.Z
ww
ww
No. Width Width Length Capacity (Lbs) *
1078"
CBS1RB 18- 5 8" 12" 3,000 *
7
10- 8"
CBS2RB 30- 5 8" 24" 1,500 *
* This load is only for the capacity of the components in this assembly.
Please consult roofing manufacturer or engineer for roof load capacity
CUSH-A-BLOCK SUPPORTS
CBS-RB SERIES WITH RAISED CHANNEL Standard strut mount pipe clamps are used to secure the pipes.
HEAVY SUPPORT
Note: Roof supports come pre-assembled
Strut
Width
16"
k
loc
-B
h-A
C us r.c
om
ste
Fo
Si-
w.Z
ww
w.Z
ww
5
CBS4RB 42- 8" 36" 3,250 * 1078"
* This load is only for the capacity of the components in this assembly.
Please consult roofing manufacturer or engineer for roof load capacity
114 www.wesanco.com
C ush -A-B lock
R ooftop S upports
CUSH-A-BLOCK SUPPORTS
Channel
CBS-DSFW SERIES, FIXED WIDTH
DUCT SUPPORT
Channel Nuts
& Hardware
Fittings
Width
Duct
Brackets
Height
Clamps
Beam
k
oc
Bl
A-
s h-
Cu
om
r.c
ste
Fo
Si-
Bases
w.Z
Post
ww
k
loc
-B
-A
sh
Cu
om
r.c
ste
Fo k
Si- loc
Caps
w.Z -B
End
ww -A
sh
Cu
om
r.c
ste
Fo
Si-
w.Z
ww
Clamps
loc
-B
-A
sh
Cu
Base
om
r.c
ste
Fo
Si-
w.Z
ww
Length
Accessories
Electrical
Concrete
Inserts
CBS-DSF Duct Support Series With Fixed Width
Base No. of Uniform Load
Model No. Height Width
Cushioned
Clamping
Length Bases Capacity (Lbs) *
CBS1-DSFW 18" 2042 *
CBS2-DSFW 24" 1531 *
23" 24" 4
CBS3-DSFW 36" 1021 *
Supports
Rooftop
CBS4-DSFW 48" 766 *
CBS5-DSFW 18" 2042 *
CBS6-DSFW 24" 1531 *
Specifications
29" 24" 4 Material
CBS7-DSFW 36" 1021 *
CBS8-DSFW 48" 766 *
CBS9-DSFW 18" 2042 *
CBS10-DSFW 24" 1531 *
Information
41" 24" 4
Design
Duct
Height
k
oc
Bl
A-
s h-
Cu om
r.c
ste
Fo
Si-
w.Z
ww
k
oc
Bl
A-
s h-
Cu r.c
om
ste k
loc
Fo
Si-
w.Z -B
ww -A
sh
Cu ste
r.c
om
Fo
Si-
w.Z
ww
k
loc
-B
-A
Cu
sh
Fo
ste
r.c
om
Base
Si-
ww
w.Z
Length
28.813" 24"
CBS3DS 38" 62-3 8" 4 967 *
(610mm)
36"
CBS4DS 62-3 8" 103- 5 8" 6 589 *
(914mm)
36" 24"
CBS7DS 38" 62-3 8" 4 967 *
(610mm)
36"
CBS8DS 62-3 8" 103- 5 8" 6 589 *
(914mm)
* This load is only for the capacity of the components in this assembly.
Please consult roofing manufacturer or engineer for roof load capacity
116 www.wesanco.com
WESTRUT M aterials
& M anufacturing D etails
Channel
General Information Fittings
Most Westrut channels are produced in 10 and 20-foot lengths with General
a length tolerance of plus or minus 116. Westrut W-700 and W-6500
Channel Nuts
Westrut fittings are manufactured by cold forming steel in punch
& Hardware
are produced in 10 foot lengths only.
press dies and conform to those tolerances listed in section 5.3 of
Metal Framing Standards publication No. MFMA-1.
Channels
Material
General
Fittings
Steel used for Westrut fittings is Hot-Rolled Pickled and Oiled strip
Westrut channels are manufactured by the cold roll forming steel or bar conforming to ASTM A 570 or ASTM A575.
process which produces cross sections of uniform dimensions
within tolerances established by the Metal framing Manufacturer's Welding
Brackets
Association, Metal Framing Standards Publication No. MFMA-1. Westrut fittings having two or more component parts may be arc
Material or resistance welded in accordance with the appropriate American
Welding Society Standards.
Clamps
Steel used in the manufacture of Westrut channels conforms to the
Beam
ASTM specifications (found on pages 6 & 118) on this catalog.
Coatings
Design Paint-Green Powder Coating
Bases
Post
Design is based on AISI "Specification for the Design of Cold-
A dark green low gloss powder coating is applied and thoroughly
Formed Steel Structural Members." Maximum bending stress used
baked after steel has been cleaned and phosphatized.
Caps
in design is 25,000 pounds per square inch (PSI). This is based
End
upon a virgin steel minimum yield stress of 33,000 PSI cold worked Electroplated
to an average yield stress of 42,000 PSI.
Clamps
Westrut fittings and hardware supplied as "Electro-Galvanized" in
Welding accordance with ASTM B 633.
Welds meet the performance requirements of section 4 of AISI Mill-Galvanized (Pre-Galvanized)
Accessories
Electrical
"Specification for the design of Cold-Formed Steel Structural Galvanized steel used in the manufacture of Westrut channel
Members." All multiple sections of two or more single Westrut sections conforms to ASTM A 653 GR33 G90. Uncoated edges
channels are resistance spot-welded approximately 2" to 3" on resulted from slitting, punching and channel cut off are present.
center.
Hot Dip Galvanized After Fabrication (HDGAF)
Concrete
Inserts
Channel Nuts Westrut channel and fittings which are hot dip galvanized after
fabrication conform to one of the following specifications.
General ASTM A 123, ASTM A153 or ASTM A386.
Cushioned
Clamping
Westrut channel nuts are formed or stamped from steel bar stock
and is case hardened after all forming and taping operations have Special Coatings
been completed. The nuts are coated with zinc to ASTM-B633 Other commercially available finishes can be supplied per
"Electrodeposited Coatings of Zinc on Iron and Steel." specification when required to protect applications.
Supports
Rooftop
Westrut channel nuts have uniform and American coarse screw
threads.
Weights and Dimensions
Channel nuts are available both with and without springs. Springs
Specifications
are made from Galvanized spring steel wire. All weights given for materials are approximate shipping weights. Material
Weights will vary somewhat due to permissible tolerances and slight
Material variations in material thickness.
The bar steel used in manufacture of Westrut channel nuts
conforms to ASTM A575 or ASTM A576.
Information
Channel Specifications
Current ASTM Previous ASTM ASTM
Material *
Designation Designation Description
[1] Hot Rolled: Channel A 1011SS GR33 A 570 GR33 Hot rolled carbon steel sheet and strip, structural quality.
[2] Cold Rolled: Channel A 1008SS GR33 A 611 Cold rolled carbon sheet steel.
Steel sheet zinc-coated by hot dip process at mill,
[3] Pregalvanized: Channel A 653 SS GR33 A 653 GR33 G90
structural quality.
A 240 TYPE 304 A 240 TYPE 304 Heat resisting chromium and chromium-nickel
[4] Stainless Steel: Channel
A 240 TYPE 316 A 240 TYPE 316 stainless steel plate, sheet, strip for pressure vessel.
[5] Aluminum: Channel B 221 TYPE 6063 T6 B 221 TYPE 6063 TS Aluminum alloy extruded bar, rod, wire, shape and tube.
Channel
Westrut Channels W-100, W-150, W-200, W-210, W-500, W-800 and W-900 are available as roll formed sections in stainless
steel, conforming to ASTM A 240, type 304 or ASTM A 240, type 316.
Channel Nuts
& Hardware
To order add "ST-304" or "ST-316" to channel designation.
Examples: W-500SS ST 304, W-200 ST 316.
Aluminum Channel
Fittings
Westrut Channels W-200, W-201, and W-500 are available as extruded aluminum sections type 6063T6, conforming to ASTM
B221. To order add "Aluminum" to channel designation.
Brackets
Example: W-201 Aluminum.
Clamps
Beam
Westrut Channel Nuts W-2-4, W-2-6 and W-2-8 are available in type 316 Stainless Steel.
- Sintered 316 - Domestic Nut ASTM: B783
- Bar Stock 316 - Import Nut ASTM: A240
Bases
Post
To order add "ST" to nut designation. Example: W-2-8 ST 316
Caps
End
Aluminum Nuts (Channel Type)
Available by special order. Consult factory for details. ASTM B221.
Clamps
Aluminum Stainless and Copper Plated Pipe Clamps
Accessories
Electrical
Westrut Pipe Clamps are available from stock in Stainless Steel types 304 and 316 and by special order in Aluminum and
Copper Plated. Refer to pages 74 and 75 for additional information. Consult factory for details.
Concrete
Aluminum Engineering Data
Inserts
To determine the appropriate beam load capacity for extruded Aluminum Channel Sections, refer to Channel Engineering Data,
page 11 & 12-33 in this catalog and multiply published values by 40%. To determine the approximate pull out slip load of Westrut
Cushioned
Clamping
Channel Nuts in extruded Aluminum Channel sections, refer to page 34 in this catalog and multiply the resistance to slip value
by 75% and the resistance to pull out value by 50%.
Supports
Rooftop
The properties of section for stainless steel channels are the same as shown starting on page 11 of this catalog for mild
steel channel. Load ratings for stainless steel channel meet or exceed corresponding mild steel ratings published throughout
this catalog.
Specifications
Material
Information
Design
Installation
Index
Hole Placement: 916" Diameter holes are aligned along a single or single intersecting centerline (C.L.), which bisects the 1-58"
(1.625") wide material (flat stock) dimension.
Hole Lead-In/Centering: The 916" Diameter holes are located in from leading edges (leading edge to hole center) 1316" (0.813"). This
lead-in dimension controls subsequent center to center positioning and unless otherwise specified or controlled by a fittings gross
dimension along a specific axis, field holes are 1-78" (1.875") center to center along the material's centerline (C.L.). Dimension from
trailing hole center to trailing edge will also be 1316" (0.813"). (ref drawings: A)
Bend Design: Design of each individual bend in this wide selection of fittings has been developed to maximize the material's
strength while reducing stress at those bend points. This allows for cohesive nesting with the formed edge radiuses of the channel
sections. This design detail provides a minimum tolerance envelope to assure a clean accurate fit and ease of assembly into
structural strut/fitting elements.
FLAT FITTINGS: Without any bend from that single plane: For use with channel sections: arranged and co-dependently utilized in a
double axis or parallel single axis, single plane situation.
A
9
16" Dia. Typ.
(unless otherwise noted)
Lead in
Edge Typ.
120 www.wesanco.com
D esign & D imensional
I nformation
Channel
Channel Nuts
& Hardware
Fittings
Brackets
Clamps
Beam
Bases
Post
Clamp halves are pushed laterally into place. ninety degrees to the channel face
and touching the pipe element sides. The bolt and nut are installed. The grip
Caps
End
design at the channel Iips tightens during assembly, securely holding the Strut
Clamp assembly in-place.
Clamps
Accessories
Electrical
FITTING DIMENSIONS AND CONTROL DATA
(STRIP I GAUGE MATERIAL FORMED PIPE CLAMP HALVES):
Unless otherwise indicated:
Concrete
Materials width: 1-14" ( 1.250") side to side, forming two identically matching strut clamp sides. Ref: E and F
Inserts
Thickness: Gauge dimensional material is utilized, specific to each individual strut clamp size. Ref. Part Number I Size chart for each
style clamp. Ref: E.
Cushioned
Clamping
Material length: Specific lengths of material required to fabricate each size strut clamp is not provided. The bolt tang also varies from
clamp size to size and style to style.
Channel twist-grip feature: Each clamp half is formed with an in-line, twist-on feature, allowing close proximity installation with a simple
Supports
Rooftop
insert-twist maneuver. The clamp halves are pushed laterally into place, ninety degrees to the channel face and touching the pipe
element sides, and the bolt / nut is installed. The grip design at the channel Iip's tightens during assembly, securely holding the strut
clamp assembly in place. Ref: E and F.
Specifications
Hole dimension / Placement: The receiving hole and bolt pass-thru hole(s) positioned in the punched tang(s),(except in the studded Material
version clamps) are identical sized with standard practice clearance tolerances. Placement and size of holes to accommodate the
mechanical studs are similarly positioned for strength and utilization in an appropriately sized punched tang.
Bolt dimensions: National Coarse Sized threaded mild steel hex head/slotted bolts are utilized; dimensions vary from clamp size to
Information
clamp size. Ref: Number /Size chart for each style clamp. Ref: E.
Design
Stud attachment: The mild steel, ASTM conformant National Coarse Size threaded studs, are press fit into an appropriately sized
receiving hole and then high resistance welded in place to further secure them against accidental loosening while the Kep nuts are
turned into position (use per specific part data call-out).
Installation
NOTE: Illustrations of Components throughout are representational. Utilize specific data as shown.
Wesanco Engineering Catalog 121
C hannel E ngineering D ata
C rush L oad for C hannel
Load Data for Channel Sections, Subject to Crushing Loads
These values are based on a minimum yield point of 33,000 PSI at safety factor of 1.85.
122 www.wesanco.com
C hannel E ngineering D ata
P oint L oad
Channel
Design Load Data for Westrut Channel Connections
Load diagrams indicate two design loads;
one for 12 gage sections (listed as W-200) and
Channel Nuts
& Hardware
one for 14 gage sections (listed as W-210)
Safety factor = 2-12 based on ultimate strength of connection.
90 Fittings
Fittings
(When used in position shown)
Brackets
Both Ends Supported Both Ends Supported
Clamps
Beam
Bases
Post
Caps
End
Clamps
Accessories
Electrical
Design Load Design Load
Part No. Part No.
in LBS. in LBS.
W-200 1500# W-200 1000#
Concrete
W-200 1000# W-210 650#
Inserts
Cushioned
Clamping
W-5113 W-5112 Flat Plate Fittings
Both Ends Supported
Design Load in Lbs. 500#
W-5007
Supports
Rooftop
Both Ends Supported
Specifications
Material
Information
Design
Installation
Design Load
Part No.
in LBS.
W-200 1500#
W-210 1000#
124 www.wesanco.com
S afe T hru -B olting
and T rapeze I nformation
Channel
Channel Nuts
& Hardware
A
D
E
C
Fittings
Brackets
B E
Clamps
Beam
Bases
Post
Single Section
C
Single Section
Caps
Perforated Channel
End
Perforated Channel
Double Section
Clamps
Perforated Channel
A
Accessories
Electrical
D
Common Components
A: Top Hex Nut
Concrete
Inserts
B: Bottom Double Hex Nuts
Cushioned
Clamping
D: Flat Fitting (W-5004 With Indents Shown).
Supports
Rooftop
F: (Not Shown) Lock Washer (S), Kep Nut(S),
or Other Security Measures as Required.
Specifications
Material
E
Over tightening face supported thru bolted all thread rod or other
Information
mechanical fasteners can distort the channel section beyond its intended
Design
Shallow channel with 14" thick 1-58" Deep Channel with 14"
1-58" Channel with 14" fitting and
fitting and 1516" max. bolt length. thick fitting and 12" all thread.
1-14" working length bolt.
126 www.wesanco.com
E lectrical I nstallation
I nstructions
Channel
These surface metal raceways are intended for use in the installation While the metal wire raceway cover provides electrical continuity to the
of electrical wiring using external joiners.. The number, type and size of base and ground wires, if screws are required, they are to be installed in
conductors, which may be installed in these raceways, are tabulated in the field. Installation shall conform to Strut-Type Channel Raceway and
Channel Nuts
& Hardware
table below. Fittings UL5B.O
Fluorescent and Incandescent Lighting
Consult your local, state and federal electrical code for all installations
Fittings
Wire Maximum Number of Electrical Wires (at 40% fill)
W-150 W-100 W-200 W-210 W-300 W-400
Type Gauge 158" x 314" 158" x 2716" 158" x 158" 158" x 158" 158" x 138" 158" x 1316"
Brackets
12 gauge 12 gauge 12 gauge 14 gauge 12 gauge 16 gauge
14 172 127 81 81 67 36
12 126 92 59 59 49 26
Clamps
Beam
FEP, FEPB 10 90 66 42 42 35 19
8 51 38 24 24 20 11
6 24 17 11 12 9 5
Bases
Post
14 52 38 24 26 20 12
12 45 33 21 22 17 10
RH, RHH,
Caps
End
10 37 27 17 18 14 8
RHW
8 20 14 9 10 7 4
Clamps
6 14 10 6 7 5 3
14 124 91 58 58 48 26
12 95 70 45 45 37 20
Accessories
Electrical
T, TW 10 69 51 33 33 27 14
8 36 26 17 18 14 8
6 21 15 9 10 8 5
14 178 131 84 84 69 37
Concrete
Inserts
12 130 95 61 61 50 27
THHN,
10 82 60 38 38 32 17
THWN
8 46 34 21 22 17 10
Cushioned
Clamping
6 33 24 15 16 12 7
14 82 61 39 39 32 17
12 66 49 31 31 26 14
Supports
THW 10 52 38 24 24 20 11
Rooftop
8 29 21 13 14 11 6
6 21 15 10 10 8 5
14
Specifications
124 91 58 58 48 26
Material
12 95 70 45 45 37 20
XHHW 10 71 52 33 33 28 15
8 37 27 17 19 14 8
6 27 20 13 14 10 6
Information
Design
support and supply electric discharge type lighting fixtures when raceway 14 10 10 6
wiring is suitable for at least 70C and clearance between fixture and 12 10 10 6
raceway is at least 18". In all cases, a snap-in cover is required to complete 10 8 6 -
the raceway enclosure.
8 6 4 -
Wire Types - T, THW, TW, TF, RUH, and RUW
Index
6 3 2 -
Wesanco Engineering Catalog 127
E lectrical I nstallation
I nstructions
These installations instructions cover strut-type channel raceway and fittings for use only in dry locations,
and in accordance with Article 352 of the National Electrical Code, NFPA 70
A B
N
R O
A W-200 (shown) Raceway Base (pages 16-17) O W-6439 - Standard Raceway Stud Plate (page 79)
Also included are Catalog Numbers W-210, W-300, W-500, W-210KO, For use with four hole raceway splice fitting (W-6432 - W-6435). Install
W-300KO, and W--500KO. with 14" KEP nuts supplied.
B W-6500 (shown) Wire Raceway Cover (page 79) P W-6432, W-6433, W-6435 - Four Hole Raceway Splice
Snap-on type (0.04" thick). Cover must be used to close 78" slot in Fitting. (page 78)
raceway base to comply with Underwriters Laboratories approved Use with either standard Raceway stud plate W-6439 or retainers as
installation required to provide adequate support; no greater than 18" on center
C W-6420 (W-6422) Channel Hanger (page 77) Q Fiber Wire Retainers.
1. Attach hanger from hanger rod using hex nuts (not included) Use retainers as required to provide adequate support; no greater
2. Place wiring in raceway base than 18" on center
3. Install raceway base into pre-hung fixture hanger R W-6462 - Aluminum Wiring Stud (1-18" long 12" -14
4. Lock fixture hanger by snapping the door closed Thread) (page 79)
5. Install wire raceway cover. Max Load 150# Fits channel open slot. Install with lock nut and plastic bushing, align
N W-6440 - Four Hole Tapped Raceway Plat for Flush and tighten securely.
Mounting. (page 78)
Install as illustrated using 14" x 58" flat head machine screws included.
See maximum number of wires tables on page 127. Always Consult your local, state and federal electrical code for all installations
128 www.wesanco.com
E lectrical I nstallation
I nstructions
Channel
Channel Nuts
& Hardware
B
Fittings
T
A
Brackets
B
M
S
Clamps
Beam
Bases
Post
D
B
Caps
End
Clamps
F
Accessories
Electrical
D
Concrete
Inserts
Cushioned
Clamping
Supports
Rooftop
A W-200 (shown) Raceway Base (pages 16-17) F W-5920 - Wire Raceway End Cap for Channels
Also included are Catalog Numbers W-210, W-300, W-500, W-210KO, (W-200, W-200KO, W-210 and W-210KO) (page 73)
W-300KO, and W--500KO. This end cap designed to fit securely into the end of raceway base.
B W-6500 (shown) Wire Raceway Cover (page 79) M W-6442 (W-6443) - Conduit Connector (page 77)
Specifications
Snap-on type (0.040" thick). Cover must be used to close 78" slot in Attach as shown with channel nuts and flat head machine screws Material
raceway base to comply with Underwriters Laboratories approved included. Install conduit connector using lock nuts and plastic bushing
installation as shown
D W-6424 (W-6426) Fixture Hanger (page 77) S W-2-8WS Channel Nut (page 35)
1. Attach hanger from hanger rod using hex nuts (not included) 1
Information
See maximum number of wires tables on page 127. Always Consult your local, state and federal electrical code for all installations
Wesanco Engineering Catalog 129
E lectrical I nstallation
I nstructions
H
A
C
A W-200 (shown) Raceway Base (pages 16-17) G W-5940 End Cap with Knockout (page 73)
Also included are Catalog Numbers W-210, W-300, W-500, W-210KO, (W-5941, W-5942 and W-5943)
W-300KO, and W--500KO. 1. Position end cap as shown
B W-6500 (shown) Wire Raceway Cover (page 79) 2. Affix with screw and channel nut supplied
Snap-on type (0.040" thick). Cover must be used to close 78" slot in 3. Attach grounding wire with green #10 screw (supplied).
raceway base to comply with Underwriters Laboratories approved H W-6445 Receptacle Box (page 78)
installation Assembly includes channel nuts and flat head machine screw. Install
C W-6420 (W-6422) Channel Hanger (page 77) as shown. Does not include receptacle cover or outlet component.
1. Attach hanger from hanger rod using hex nuts (not included)
2 Place wiring in raceway base
3. Install raceway base into pre-hung fixture hanger
4. Lock fixture hanger by snapping the door closed
5. Install wire raceway cover. Max Load 150#
See maximum number of wires tables on page 127. Always Consult your local, state and federal electrical code for all installations
130 www.wesanco.com
E lectrical I nstallation
I nstructions
Channel
Channel Nuts
& Hardware
Fittings
Brackets
B
I
Clamps
Beam
Bases
Post
Caps
End
Clamps
J
A
Accessories
K
Electrical
A
Concrete
Inserts
Cushioned
Clamping
Supports
Rooftop
A W-200 (shown) Raceway Base (pages 16-17) J W-6460 - Fixture Stud (page 79)
Also included are Catalog Numbers W-210, W-300, W-500, W-210KO, This fixture stud offers an alternative means of attaching fixture to the
W-300KO, and W--500KO. slot side of support channel. Install with washers and hex nuts.
Specifications
B W-6500 (shown) Wire Raceway Cover (page 79) K W-6461 - Fixture Nut (14"x20) (page 79) Material
7
Snap-on type (0.040" thick). Cover must be used to close 8" slot in Provides optional method of attaching fixture. Install with 14" washer
raceway base to comply with Underwriters Laboratories approved and hex head cap screws supplied.
installation
I W-6449 - Outlet Box Connection Fitting (page 78)
Information
Design
Install as shown using flat head machine screws and channel nuts
(supplied), use chase nipple, plastic bushing and lock nut to attach
electrical box to connection fitting.
Installation
Index
See maximum number of wires tables on page 127. Always Consult your local, state and federal electrical code for all installations
Wesanco Engineering Catalog 131
B eta C lamp T echnical D ata
Ma
Lo x. Sl Max. Pipe Slip indicates that
ad ip
(A) Sliding starts when the specified
values (A) are reached.
Pipe OD Spacing
in (mm) ft - in. (m)
0.24" 0.5" (6 12.7) 3' - 3" (1)
0.5" 0.87" (12.7 22) 3' - 11" (1.2)
0.87" 1.26" (22 32) 4' - 11" (1.5) BETA CLAMP MATERIAL PROPERTIES
1.26" 1.5" (32 38) 6' - 7" (2) Polypropylene (PP) Cushion
1.5" 2.24" (38 57) 8' - 10" (2.7) Material Properties
2.24" 2.95" (57 75) 9' - 10" (3) Density 0.906 g/cm3
2.95" 3" (75 76.1) 11' - 6" (3.5) Tensile strength DIN 53454 25-35 N/mm2
3" 3.5" (76.1 88.9) 12' - 2" (3.7) Flexure stress limit DIN 53452 36N N/mm2
3.5" 4" (88.9 102) 13' - 1" (4) Compressive strength DIN 53454 90 N/mm2
4" 4.5" (102 114) 14' - 9" (4.5) Impact strength DIN 53453 No break
4.5" 6.6" (114 168) 16' - 5" (5)
Thermo Properties
6.6" 8.6" (168 219) 19' - 8" (6)
Max. temp. resistance -30 to 90C
8.6" 12.8" (219 324) 21' - 12" (6.7)
Thermal conductivity 15 x 10-5 /C
12.8" 14" (324 356) 22' - 12" (7)
Linear expansion coeff. 0.22 W/[mk]
14" 16" (356 406) 24' - 7" (7.5)
16" 16.5" (406 419) 26' - 11" (8.2) Electrical Properties
16.5" 20" (419 508) 27' - 11" (8.5) Specific volume DIN 53482 1016 ohm x cm
20" 20.5" (508 521) 29' - 6" (9) Chemical Properties
20.5" 22" (521 558) 32' - 10" (10) Consistent for weak acids, solvents, mineral oils
22" 31.5" (558 800) 41' - 0" (12.5) and seawater.
132 www.wesanco.com
B eta C lamp I nstallation
Installation on Channel
Channel
1
The Z-Strut Nuts can be used with any clamp using a 4-20 mounting bolt. This includes:
Standard-Series
Channel Nuts
& Hardware
Twin-Series (T1 Only)
Beta Rubber Inserts
Fittings
(1) Insert Z-Strut Nuts
Brackets
Into Z-Strut Channel
And Turn to Lock
Clamps
Beam
(2) Push Bottom Half
of Clamp Onto Z-Strut Nuts
Bases
Post
Caps
End
Clamps
Accessories
Electrical
(3) Install Pipe
Concrete
Inserts
(4) Add Top Cushion
Cushioned
Clamping
Supports
Rooftop
(5) Add Top Plate
and Bolt Into Position
Specifications
Material
Information
Design
Installation
NOTE: The Z-Strut Nut will slide within the Z-Strut Channel so
clamp units can be adjusted before being firmly bolted.
Index
Description...........................................................................................Page Description...........................................................................................Page
134 www.wesanco.com
K eyword I ndex
Description...........................................................................................Page Description...........................................................................................Page
Channel
MIG Welded To Meet Specific Engineering Request. . . . . . 10 Table of Contents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Mill-Galvanized (Pre-Galvanized). . . . . . . . . . . . . . . . . . . 117 Threaded Rod. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Channel Nuts
& Hardware
Mini Nut With Short Spring . . . . . . . . . . . . . . . . . . . . . . . . . 36 Trolly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Mini Nut With Standard Spring . . . . . . . . . . . . . . . . . . . . . . 36 Two Hole Clevis Connector. . . . . . . . . . . . . . . . . . . . . . . . . 47
Omega Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95 Two Hole Zee Connectors. . . . . . . . . . . . . . . . . . . . . . . . . . 44
Fittings
One-Hole Tubing Clamps . . . . . . . . . . . . . . . . . . . . . . . . . . 76 Two-Hole Angle. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Outside/Inside Corner Styles. . . . . . . . . . . . . . . . . . . . 88 - 89 Typical Anchor Tab Detail . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Brackets
Paint-Green Powder Coating. . . . . . . . . . . . . . . . . . . . . . . 117 Utility Brackets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 65
Perforated Selections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 W-100 & W-101 Strut - 12 Gauge - 158" x 2716" . . . . . 12 13
Porce-A-Clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 W-150 & W-151 Strut - 12 Gauge - 158" x 314". . . . . . 14 15
Clamps
Beam
Post Bases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 72 W-200 & W-201 Strut - 12 Gauge - 158" x 158". . . . . . 16 17
Quick-Clip, Cush-A-Click. . . . . . . . . . . . . . . . . . . . . . . . . . 108 W-200 Continuous Concrete Inserts. . . . . . . . . . . . . . . . . . 82
Bases
Post
Radiused Combinations . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 W-210 & W-211 Strut - 14 Gauge - 158" x 158". . . . . . 18 19
Rooftop Supports. . . . . . . . . . . . . . . . . . . . . . . . . . . 109 - 116 W-300 & W-301 Strut - 12 Gauge - 158" x 138". . . . . . 20 21
Caps
End
Saddle-Up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 W-300 Continuous Concrete Inserts. . . . . . . . . . . . . . . . . . 83
Clamps
Safe Thru-Bolting and Trapeze Information. . . . . . . . . . . . 125 W-400 & W-401 Strut - 16 Gauge - 158" x 1316" . . . . . 22 23
Shelf Brackets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 56 W-500 & W-501 Strut - 14 Gauge - 158" x 1316" . . . . . 24 25
W-600 & W-601 Strut - 19 Gauge - 1316" x 1316". . . . . 26 27
Accessories
Shelf Brackets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Electrical
Short Slot. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 W-700 & W-701 Strut - 19 Gauge - 1316" x 1332". . . . . 28 29
Single Section Perforated Channel. . . . . . . . . . . . . . . . . . 125 W-800 & W-801 Strut - 12 Gauge - 158" x 1". . . . . . . . 30 31
Slip And Pull-Out Load Data. . . . . . . . . . . . . . . . . . . . . . . . 34 W-800 Continuous Concrete Inserts. . . . . . . . . . . . . . . . . . 84
Concrete
Inserts
Slotted Channel Combinations. . . . . . . . . . . . . . . . . . . . . . . 9 W-900 & W-901 Strut - 12 Gauge - 158" x 78". . . . . . . 32 33
Small Hardware. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 W-900 Continuous Concrete Inserts. . . . . . . . . . . . . . . . . . 85
Cushioned
Clamping
Snap-A-Saddle. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 WESTRUT Channel Combinations. . . . . . . . . . . . . . . 8 10
Special Coatings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 WESTRUT Channel Profiles. . . . . . . . . . . . . . . . . . . . . . . . 7
Special Materials Pipe Clamps. . . . . . . . . . . . . . . . . . . . . . 75 WESTRUT Framing Channel System. . . . . . . . . . . . . . . . . 2
Supports
Rooftop
Special Metals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 WESTRUT Installation . . . . . . . . . . . . . . . . . . . . . . . . . 4 -- 5
Specialty Combinations. . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 WESTRUT Installation Channel Nut With Spring. . . . . . . . 5
Specifications
Specialty Punch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 WESTRUT Installation Channel Nut Without Spring . . . . . 4 Material
Spot Concrete Insert. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 WESTRUT Materials & Manufacturing Details. . . . . . . . 117
Springless Nut Platform. . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 Wing Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 53
Stainless Steel Channel . . . . . . . . . . . . . . . . . . . . . . . . . . 119 Zee Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Information
Design
Part No........................ Page Part No........................ Page Part No........................ Page Part No........................ Page Part No........................ Page
004M007.....................................95 046CC058................................101 CBS3RB...................................114 S1004C.....................................103 UX1210.....................................106
004MS007..................................95 046M052.....................................95 CBS3RD................................... 111 S1006.......................................102 UX1212.....................................106
006CC018................................101 046MS052..................................95 CBS3S...................................... 111 S1007.......................................102 UX1215.....................................106
006CC018S..............................101 048CC058................................101 CBS4-DSFW............................115 S2008.......................................102 UX1234.....................................106
006CC018SH...........................101 050CC058................................101 CBS42BR.................................112 S2009.......................................102 UX13810...................................106
006CC018Z..............................101 050M056.....................................95 CBS4D...................................... 111 S2010.......................................102 UX13812...................................106
006CC018ZH............................101 050MS056..................................95 CBS4DS...................................116 S2011.......................................102 UX13815...................................106
006M008.....................................95 052CC066................................101 CBS4PRB.................................112 S3012.......................................102 UX13820...................................106
006MS008..................................95 054CC066................................101 CBS4RB...................................114 S3014.......................................102 UX13834...................................106
008CC018................................101 056CC066................................101 CBS4RD................................... 111 S3015.......................................102 UX1410.....................................106
008M011.....................................95 056M062.....................................95 CBS4S...................................... 111 S3016.......................................102 UX1412.....................................106
008MS011..................................95 056MS062..................................95 CBS5-DSFW............................115 S4017.......................................102 UX1434.....................................106
010CC018................................101 058CC066................................101 CBS50BR.................................112 S4018.......................................102 UX15810...................................106
010M013.....................................95 058M064.....................................95 CBS5DS...................................116 S5020.......................................102 UX15812...................................106
010MS013..................................95 058MS064..................................95 CBS6-DSFW............................115 S5021.......................................102 UX15815...................................106
012CC026................................101 060CC074................................101 CBS60BR.................................112 S5024.......................................102 UX15820...................................106
012M015.....................................95 062CC074................................101 CBS6DS...................................116 S5027.......................................102 UX15834...................................106
012MS015..................................95 064CC074................................101 CBS7-DSFW............................115 S6028.......................................102 UX17810...................................106
014CC026................................101 064M072.....................................95 CBS7DS...................................116 S6030.......................................102 UX17812...................................106
014M017.....................................95 064MS072..................................95 CBS8-DSFW............................115 S6032.......................................102 UX17815...................................106
014MS017..................................95 066CC074................................101 CBS8DS...................................116 S7036.......................................102 UX17820...................................106
016CC026................................101 066M074.....................................95 CBS8EX...................................113 S7038.......................................102 UX17834...................................106
016M019.....................................95 066MS074..................................95 CBS9-DSFW............................115 S7040.......................................102 UX21810...................................106
016MS019..................................95 068CC080................................101 CC12 thru CC34.......................108 S7044.......................................102 UX21812...................................106
018CC026................................101 070CC080................................101 CG-10 thru CG-40......................97 S7048.......................................102 UX21815...................................106
018M020.....................................95 072CC080................................101 CL-04 thru CL-18........................96 SB1 thru SB6............................103 UX21820...................................106
018M021.....................................95 072M080.....................................95 CLS-04 thru CLS-18...................96 SB225 thru SB825....................105 UX21834...................................106
018MS020..................................95 072MS080..................................95 CN04 thru CN72.........................93 SC-1 thru SC-6.........................103 UX23810...................................106
018MS021..................................95 082M090.....................................95 CN04S6 thru CN72S6................93 SCP1 thru SCP7......................103 UX23812...................................106
020CC034................................101 082MS090..................................95 CN04SS thru CN72SS...............93 SD150 thru SD650...................104 UX23815...................................106
020M024.....................................95 089M096.....................................95 CN14P thru CN72P....................93 SHB1 thru SHB7......................103 UX23820...................................106
020MS024..................................95 089MS096..................................95 CN14PS6 thru CN72PS6...........93 SM1006 thru SM5035..............102 UX23834...................................106
021M026.....................................95 098M106.....................................95 CN14PSS thru CN72PSS..........93 SP1 thru SP6............................103 UX25810...................................106
021MS026..................................95 098MS106..................................95 CS030.........................................99 SW225 thru SW825..................105 UX25812...................................106
022CC034................................101 106M114.....................................95 CS032.........................................99 SWP1 thru SWP7.....................103 UX25815...................................106
022M026.....................................95 106MS114..................................95 CS034.........................................99 UB1/2PA...................................100 UX25820...................................106
022MS026..................................95 AS1.............................................98 CS036.........................................99 UB1/2PA6.................................100 UX25834...................................106
024CC034................................101 CBS..........................................110 CS038.........................................99 UB1/2PAN................................100 UX27810...................................106
024M028.....................................95 CBS-Mini..................................110 CS040.........................................99 UB1/2PAN6..............................100 UX27812...................................106
024MS028..................................95 CBS1-DSFW............................115 CS042.........................................99 UB1/2PANH..............................100 UX27815...................................106
026CC034................................101 CBS10-DSFW..........................115 CS044.........................................99 UB1/2PANH6............................100 UX27820...................................106
026M030.....................................95 CBS11-DSFW...........................115 CS048.........................................99 UB3/4PA...................................100 UX27834...................................106
026MS030..................................95 CBS12-DSFW..........................115 CS050.........................................99 UB7/8TA ..................................100 UX31210...................................106
027M032.....................................95 CBS12EX.................................113 CS054.........................................99 UB1-1/4PA................................100 UX31212...................................106
027MS032..................................95 CBS13-DSFW..........................115 CS060.........................................99 UB1-1/4TA ...............................100 UX31215...................................106
028CC042................................101 CBS14-DSFW..........................115 CS068.........................................99 UB1-3/8TA................................100 UX31220...................................106
028M032.....................................95 CBS15-DSFW..........................115 CS076.........................................99 UB1-1/2PA................................100 UX31234...................................106
028MS032..................................95 CBS16-DSFW..........................115 CS092.........................................99 UB12PA....................................100 UX31810...................................106
030CC042................................101 CBS16EX.................................113 CS110.........................................99 UB1PA......................................100 UX31812...................................106
030M034.....................................95 CBS1D...................................... 111 EMT-1.........................................96 UB1TA .....................................100 UX31815...................................106
030MS034..................................95 CBS1DS...................................116 EMT-1/2......................................96 UB2-1/2PA................................100 UX31820...................................106
032CC042................................101 CBS1PRB.................................112 EMT-3/4......................................96 UB2PA......................................100 UX31834...................................106
032M036.....................................95 CBS1RB...................................114 EMTS-1......................................96 UB3-1/2PA................................100 UX3410.....................................106
032MS036..................................95 CBS1RD................................... 111 EMTS-1/2...................................96 UB3PA......................................100 UX3412.....................................106
034CC042................................101 CBS1S...................................... 111 EMTS-3/4...................................96 UB3TA......................................100 UX3415.....................................106
034M040.....................................95 CBS2-DSFW............................115 HT04 thru HT72..........................93 UB4PA......................................100 UX3420.....................................106
034MS040..................................95 CBS28BR.................................112 HT04S6 thru HT72S6.................93 UB4TA......................................100 UX3434.....................................106
036CC050................................101 CBS2D...................................... 111 HT04SS thru HT72SS................93 UB5PA......................................100 UX35810...................................106
038CC050................................101 CBS2DS...................................116 N008C thru N110C.....................99 UB5TA......................................100 UX35812...................................106
038M044.....................................95 CBS2PRB.................................112 NS008 thru NS028.....................99 UB6PA......................................100 UX35815...................................106
038MS044..................................95 CBS2RB...................................114 QC12 thru QC34......................108 UB6TA......................................100 UX35820...................................106
040CC050................................101 CBS2RD................................... 111 RPC-3/8......................................97 UB8PA......................................100 UX35834...................................106
040M046.....................................95 CBS2S...................................... 111 RPC-1/2......................................97 UB10PA....................................100 UX3810.....................................106
040MS046..................................95 CBS3-DSFW............................115 RPC-5/8......................................97 UX11810...................................106 UX3812.....................................106
042CC050................................101 CBS36BR.................................112 RPC-3/4......................................97 UX11812...................................106 UX3815.....................................106
042M048.....................................95 CBS3D...................................... 111 RPC-7/8......................................97 UX11815...................................106 UX3834.....................................106
042MS048..................................95 CBS3DS...................................116 RPC-1-1/8...................................97 UX11820...................................106 UX41810...................................106
044CC058................................101 CBS3PRB.................................112 S1004.......................................102 UX11834...................................106 UX41812...................................106
136 www.wesanco.com
P art N umber I ndex
Part No........................ Page Part No........................ Page Part No........................ Page Part No........................ Page Part No........................ Page
Channel
UX41815...................................106 W-201.................................. 16, 17 W-5123.......................................43 W-5602.......................................55 W-5721 ......................................68
UX41820...................................106 W-210................... 18, 19, 34, 118, W-5123 ....................................124 W-5603 ......................................55 W-5722 ......................................68
UX41834...................................106 ................................ 122, 123, 124 W-5124.......................................43 W-5604.......................................55 W-5723 ......................................68
UX5810.....................................106 W-211.................................. 18, 19 W-5124W....................................43 W-5605 ......................................55 W-5724 ......................................68
Channel Nuts
& Hardware
UX5812.....................................106 W-27WS.....................................35 W-5125.......................................43 W-5606.......................................55 W-5725 ......................................68
UX5815.....................................106 W-300...... 20, 21, 34, 44, 118, 122 W-5135.......................................43 W-5607.......................................55 W-5726.......................................68
UX5820.....................................106 W-301.................................. 20, 21 W-5136.......................................43 W-5608.......................................55 W-5727 ......................................68
UX5834.....................................106 W-4-1SN.....................................36 W-5202.......................................44 W-5609.......................................55 W-5728 ......................................68
UX7810.....................................106 W-4-2SN.....................................36 W-5205.......................................44 W-5610.......................................55 W-5729 ......................................68
Fittings
UX7812.....................................106 W-4-3SN.....................................36 W-5209.......................................44 W-5611.......................................55 W-5731.......................................68
UX7815.....................................106 W-400...........................22, 23, 118 W-5210.......................................44 W-5612.......................................55 W-5732.......................................68
UX7820.....................................106 W-400, W-500................... 44, 103 W-5211.......................................44 W-5613.......................................55 W-5733.......................................68
UX7834.....................................106 W-401.................................. 22, 23 W-5212 ......................................44 W-5614.......................................55 W-5734.......................................68
Brackets
W-1-10 .......................................35 W-5-0832....................................35 W-5213.......................................44 W-5615.......................................55 W-5735.......................................68
W-1-12 .......................................35 W-5-10 .......................................35 W-5215.......................................44 W-5616.......................................55 W-5736.......................................68
W-1-4 .........................................35 W-5-1024....................................35 W-5218.......................................44 W-5617.......................................55 W-5737.......................................68
W-1-6 .........................................35 W-5-1032....................................35 W-5224.......................................44 W-5618.......................................55 W-5738.......................................68
W-1-8 .........................................35 W-5-10WS..................................35 W-5225.......................................44 W-5619.......................................56 W-5739.......................................68
Clamps
Beam
W-10-2SN...................................36 W-5-4..........................................35 W-5226.......................................44 W-5620.......................................56 W-5741 ......................................70
W-10-3SN...................................36 W-5-5 .........................................35 W-5227.......................................44 W-5621.......................................56 W-5742 ......................................70
W-100.................... 12, 13, 44, 118 W-5-6 .........................................35 W-5228.......................................44 W-5622.......................................56 W-5743 ......................................70
Bases
W-1007-Y...................................62 W-5-8..........................................34 W-5307.......................................45 W-5623.......................................56 W-5744 ......................................70
Post
W-101............................ 12, 13, 44 W-5-8 .........................................35 W-5308.......................................45 W-5624.......................................56 W-5745 ......................................70
W-1010-X...................................62 W-5-8TL......................................36 W-5310.......................................45 W-5625.......................................56 W-5750.......................................70
W-5-8WS....................................35 W-5626.......................................56
Caps
W-1011-X....................................62 W-5311.......................................45 W-5751.......................................70
End
W-1012-X...................................62 W-500............ 24, 25, 34, 118, 122 W-5312.......................................46 W-5631.......................................57 W-5760.......................................70
W-1013-X...................................63 W-5002.......................................39 W-5313.......................................46 W-5632.......................................57 W-5810.......................................71
W-5003.......................................39 W-5633.......................................57
Clamps
W-1015-X...................................64 W-5315 ......................................46 W-5810 FL..................................71
W-1016-X...................................63 W-5004.......................................39 W-5316.......................................46 W-5634.......................................57 W-5811.......................................71
W-1017.......................................64 W-5005.......................................39 W-5317.......................................47 W-5635.......................................57 W-5812.......................................71
W-1017-A-Y ...............................64 W-5006.......................................39 W-5318.......................................47 W-5636.......................................57 W-5813.......................................71
Accessories
W-1017-AR-A-Y .........................64 W-5007.............................. 39, 123 W-5324.......................................47 W-5637.......................................57 W-5814.......................................72
Electrical
W-1019-Y...................................64 W-5008.......................................39 W-5325.......................................47 W-5638.......................................57 W-5814SQ..................................72
W-1021-X/Y................................65 W-5009 ......................................39 W-5326.......................................47 W-5641.......................................57 W-5815.......................................72
W-1023-Y...................................65 W-501.................................. 24, 25 W-5327.......................................47 W-5642.......................................57 W-5816.......................................72
W-150...........................14, 15, 118 W-5010 ......................................39 W-5328.......................................47 W-5645.......................................57 W-5816SQ..................................72
W-151.................................. 14, 15 W-5011.......................................39 W-5342.......................................48 W-5646.......................................57 W-5900.......................................73
Concrete
Inserts
W-2-0832....................................35 W-5012.......................................39 W-5343 ......................................48 W-5647.......................................58 W-5900-M...................................73
W-2-0832TL................................36 W-5013.......................................39 W-5344.......................................48 W-5648.......................................58 W-5910.......................................73
W-2-0832WS..............................35 W-5021.......................................39 W-5345.......................................48 W-5650 ......................................59 W-5918........................ , 87, 88, 89
W-2-10........................................35 W-5022.......................................40 W-5346.......................................48 W-5651 ......................................59 W-5920.......................................73
Cushioned
Clamping
W-2-1024....................................35 W-5023.......................................40 W-5413.......................................49 W-5652.......................................58 W-5930................................ 73, 82
W-2-1024TL................................36 W-5024.......................................40 W-5415.......................................49 W-5653.......................................58 W-5930-M...................................73
W-2-1024WS..............................35 W-5025.......................................40 W-5423.......................................49 W-5654.......................................58 W-5931.......................................73
W-2-1032....................................35 W-5026.......................................40 W-5425.......................................49 W-5655.......................................58 W-5933.......................... 73, 83, 87
W-2-1032TL................................36 W-5027.......................................40 W-5427.......................................49 W-5656.......................................58 W-5935................................ 73, 85
Supports
Rooftop
W-2-1032WS..............................35 W-5052.......................................39 W-5443.......................................49 W-5661.......................................59 W-5935-M...................................73
W-2-10WS..................................35 W-5052.......................................39 W-5445.......................................49 W-5662 ......................................59 W-5938.......................... 73, 84, 84
W-2-12........................................35 W-5053.......................................39 W-5447.......................................49 W-5663.......................................59 W-5940.......................................73
W-2-12WS..................................35 W-5054.......................................39 W-5463.......................................49 W-5664.......................................59 W-5941.......................................73
Specifications
W-2-14........................................35 W-5055.......................................39 W-5465.......................................49 W-5669.......................................60 W-5942.......................................73
Material
W-2-4..........................................35 W-5056.......................................39 W-5472.......................................50 W-5671.......................................60 W-5943.......................................73
W-2-4TL......................................36 W-5102.............................. 41, 123 W-5473.......................................50 W-5673.......................................60 W-5952.......................................82
W-2-4WS....................................35 W-5103...................... 41, 123, 123 W-5474.......................................50 W-5675.......................................61 W-5953.......................................83
W-2-5..........................................35 W-5104.......................................41 W-5475.......................................50 W-5677.......................................61 W-5958.......................................84
W-2-5TL......................................36 W-5105.......................................41 W-5480.......................................50 W-5702.......................................69 W-6-0832....................................36
Information
................................ 122, 123, 124 W-5121.....................................124 W-5519.......................................53 W-5718.......................................68 W-600...........................26, 27, 118
W-200, W-210..........................103 W-5122.............................. 43, 124 W-5601.......................................55 W-5719.......................................68 W-601.................................. 26, 27
Wesanco Engineering Catalog 137
P art N umber I ndex
Part No........................ Page Part No........................ Page Part No........................ Page Part No........................ Page Part No........................ Page
W-6025 ......................................74 W-6267.......................................75 W-7252.......................................82 W-7433.......................................37 W-7850.......................................76
W-6026 ......................................74 W-6268.......................................75 W-7253.......................................82 W-7440.......................................37 W-7854.......................................76
W-6028 ......................................74 W-6269.......................................75 W-7254.......................................82 W-7441.......................................37 W-7862.......................................76
W-6030 ......................................74 W-6270.......................................75 W-7255.......................................82 W-7442.......................................37 W-7870.......................................76
W-6032 ......................................74 W-6274.......................................75 W-7256.......................................82 W-7443.......................................37 W-7950 to W-7970.....................85
W-6034.......................................75 W-6278.......................................75 W-7257.......................................82 W-7450.......................................37 W-7954.......................................85
W-6034 ......................................74 W-6282.......................................75 W-7257A.....................................82 W-7451.......................................37 W-7954 - W-7970.......................85
W-6038 ......................................74 W-6420.......................................77 W-7258.......................................82 W-7452.......................................37 W-7954 to W-7970.....................85
W-6055 ......................................74 W-6422.......................................77 W-7259.......................................82 W-7460.......................................37 W-7955.......................................85
W-6056 ......................................74 W-6424.......................................77 W-7260.......................................82 W-7461.......................................37 W-7956.......................................85
W-6058 ......................................74 W-6426.......................................77 W-7261.......................................82 W-7462.......................................37 W-7957.......................................85
W-6060 ......................................74 W-6432.......................................78 W-7262.......................................82 W-7463.......................................37 W-7957A.....................................85
W-6062 ......................................74 W-6432 ......................................78 W-7263.......................................82 W-7464.......................................37 W-7958.......................................85
W-6064 ......................................74 W-6433.......................................78 W-7264.......................................82 W-7470.......................................37 W-7959.......................................85
W-6068 ......................................74 W-6435.......................................78 W-7265.......................................82 W-7471.......................................37 W-7960.......................................85
W-6125.......................................74 W-6439.......................................78 W-7266.......................................82 W-7472.......................................37 W-7961.......................................85
W-6126.......................................74 W-6440.......................................78 W-7267.......................................82 W-7473.......................................37 W-7962.......................................85
W-6128.......................................74 W-6442.......................................77 W-7268.......................................82 W-7474.......................................37 W-7963.......................................85
W-6130.......................................74 W-6443.......................................77 W-7269.......................................82 W-7475.......................................37 W-7964.......................................85
W-6132.......................................74 W-6445.......................................78 W-7270.......................................82 W-7476.......................................37 W-7965.......................................85
W-6134.......................................74 W-6449.......................................78 W-7350.......................................83 W-7477.......................................37 W-7966.......................................85
W-6138................................ 74, 75 W-6460.......................................79 W-7351.......................................83 W-7478.......................................37 W-7967.......................................85
W-6142................................ 74, 75 W-6461.......................................79 W-7352.......................................83 W-7479.......................................37 W-7968.......................................85
W-6146................................ 74, 75 W-6462.......................................79 W-7353.......................................83 W-7480.......................................37 W-7969.......................................85
W-6150................................ 74, 75 W-6463.......................................79 W-7354.......................................83 W-7481.......................................37 W-7970.......................................85
W-6154................................ 74, 75 W-6500.......................................79 W-7355.......................................83 W-7482.......................................37 W-8-2SN.....................................36
W-6162.......................................74 W-6518.......................... 86, 88, 89 W-7356.......................................83 W-7483.......................................37 W-8-3SN.....................................36
W-6170.......................................74 W-6600.......................................54 W-7357.......................................83 W-7490.......................................37 W-8-4SN.....................................36
W-6174.......................................74 W-6601.......................................54 W-7357A.....................................83 W-7491.......................................37 W-8-5SN.....................................36
W-6176.......................................74 W-6602.......................................54 W-7358.......................................83 W-7492.......................................37 W-8-6SN.....................................36
W-6178.......................................74 W-6603.......................................54 W-7359.......................................83 W-7550.......................................84 W-800............ 30, 31, 44, 103, 118
W-6224.......................................75 W-6604.......................................54 W-7360.......................................83 W-7551.......................................84 W-801.................................. 30, 31
W-6225.......................................75 W-6905.......................................80 W-7361.......................................83 W-7552.......................................84 W-900.................. 32, 33, 103, 118
W-6226.......................................75 W-6906.......................................80 W-7362.......................................83 W-7553.......................................84 W-901.................................. 32, 33
W-6227.......................................75 W-6910.......................................80 W-7363.......................................83 W-7554.......................................84 W-9318.......................... 86, 88, 89
W-6228.......................................75 W-6911.......................................80 W-7364.......................................83 W-7555.......................................84 W-9318-135 IS..........................88
W-6229.......................................75 W-6915.......................................80 W-7365.......................................83 W-7556.......................................84 W-9318-90 OS..........................89
W-6230.......................................75 W-6916.......................................80 W-7366.......................................83 W-7557.......................................84 W-9318-IS..................................89
W-6231.......................................75 W-6920.......................................80 W-7367.......................................83 W-7557A.....................................84 W-9319.......................................86
W-6232.......................................75 W-6921.......................................80 W-7368.......................................83 W-7558.......................................84 W-9319 - 135 IS.......................88
W-6233.......................................75 W-7-0832....................................36 W-7369.......................................83 W-7559.......................................84 W-9319 IS/OS............................88
W-6234.......................................75 W-7-0836....................................36 W-7370.......................................83 W-7560.......................................84 W-9319-135 OS........................88
W-6235.......................................75 W-7-1024....................................36 W-7400.......................................37 W-7561.......................................84 W-9319-90 IS............................89
W-6237.......................................75 W-7-1032....................................36 W-7401.......................................37 W-7562.......................................84 W-9320.................... 81, 87, 89, 86
W-6238.......................................75 W-7-4..........................................36 W-7401SH..................................37 W-7563.......................................84 W-9350.......................................87
W-6239.......................................75 W-700...........................28, 29, 118 W-7402.......................................37 W-7564.......................................84 W-9351.......................................87
W-6240.......................................75 W-7000.......................................81 W-7403.......................................37 W-7565.......................................84 W-9352.......................................87
W-6242.......................................75 W-701.................................. 28, 29 W-7404.......................................37 W-7566.......................................84 W-9353.......................................87
W-6243.......................................75 W-7024.......................................81 W-7405.......................................37 W-7567.......................................84 W-9354.......................................87
W-6244.......................................75 W-7024.......................................81 W-7406.......................................37 W-7568.......................................84 W-9355.......................................87
W-6246.......................................75 W-7025.......................................81 W-7407.......................................37 W-7569.......................................84 W-9356.......................................87
W-6247.......................................75 W-7026.......................................81 W-7408.......................................37 W-7570.......................................84 W-9357.......................................87
W-6248.......................................75 W-7027.......................................81 W-7409.......................................37 W-7724.......................................76 W-9357A.....................................87
W-6249.......................................75 W-7028.......................................81 W-7410.......................................37 W-7724A.....................................76 W-9358.......................................87
W-6251.......................................75 W-7029.......................................81 W-7411.......................................37 W-7725.......................................76 W-9359.......................................87
W-6252.......................................75 W-7124.......................................38 W-7412.......................................37 W-7726.......................................76 W-9360.......................................87
W-6253.......................................75 W-7125.......................................38 W-7413.......................................37 W-7727.......................................76 W-9361.......................................87
W-6255.......................................75 W-7126.......................................38 W-7414.......................................37 W-7728.......................................76 W-9362.......................................87
W-6256.......................................75 W-7127.......................................38 W-7415.......................................37 W-7729.......................................76 W-9363.......................................87
W-6257.......................................75 W-7128.......................................38 W-7416.......................................37 W-7730.......................................76 W-9364.......................................87
W-6259.......................................75 W-7134.......................................38 W-7420.......................................37 W-7826.......................................76 W-9365.......................................87
W-6260.......................................75 W-7134A.....................................38 W-7421.......................................37 W-7828.......................................76 W-9366.......................................87
W-6261.......................................75 W-7135.......................................38 W-7422.......................................37 W-7830.......................................76 W-9367.......................................87
W-6262.......................................75 W-7136.......................................38 W-7423.......................................37 W-7832.......................................76 W-9368.......................................87
W-6263.......................................75 W-7137.......................................38 W-7424.......................................37 W-7834.......................................76 W-9369.......................................87
W-6264.......................................75 W-7138.......................................38 W-7430.......................................37 W-7838.......................................76 W-9370.......................................87
W-6265.......................................75 W-7250.......................................82 W-7431.......................................37 W-7842.......................................76 ZSA-1.......................................103
W-6266.......................................75 W-7251.......................................82 W-7432.......................................37 W-7846.......................................76 ZSA1-8.....................................103
138 www.wesanco.com
A Sampling of Additional
ZSi-Foster Products
LOOP CLAMPS BETA CLAMPS
Clamps that can be slipped over a tube or wire and closed Beta Clamps are ideal for clamping pipe, tube, hose, and electric
with a bolt at assembly. Holes provide easy alignment. cables. They are an economical and easy way of securing them in
E.P.D.M. cushion for electrical insulation and vibration all types of terrestrial, marine, O.E.M. and Industrial applications.
absorption. The steel clamps are zinc electroplated for Beta Clamps are used in all areas of industrial, mobile and marine
corrosion resistance hydraulics, general industrial pipe construction, the field of press
technology, instrumentation and control technology and many more.
Beta Clamps offer shock-absorption, vibration dampening and
noise reducing properties.
Using weldable plates, its easy to anchor the clamps
Clamp Body Standard Polypropylene -22F to 194F
GAMMA PADS Aluminum is available for use in high heat applications
The effects of vibration, shock, surge, galvanic corrosion and Upper & lower plates available in Stainless Steels
unwanted noise are a major concern. Improperly cushioned
equipment, pipe, tube, or hose invites failure and potential
problems. New developments in cushioned clamping and
vibration isolation products from ZSI provide the proper
solutions to combat these effects.
Z-CLAMP PRODUCTS
The Z-Clamp is designed to maintain a consistent center line dimension for horizontal clamping or vertical stackable clamping
applications. Z-Clamp maintains that center line while accommodating the same, or different diameter tubing, hose or pipe. Suited for
all types of hydraulic hose, tubing, and pipe clamping applications, the Z-Clamp provides yet another alternative to the broadest cushion
clamping product line in the world. The Z-Clamp consists of an adapter framework which is offered in two versions. One has mounting
bolts between each adapter insert and the other has two additional mounting bolts at each end of the frame.
ZSi
Foster