Sunteți pe pagina 1din 1

Calculation Sheet

Project Calcs for Pile Cap PC55

Structure Design Data Page of


Calcs by Calcs Date / / Revision
+ 6.0
Z
Mz 800
2300 10000 long
G.L.
X
Mx
500
2520 1500
2 1
5
+ 2.68 GWT

3
1500
480 6 7
4
1000

2300
SECTION

Servicability Design Forces


Vertical Load: (no. of columns)
P (from Column) = 227 3 = 681.0 kN
DL (Footing) = 24.5 2.3 1.5 10.0
+ 24.5 1.0 2.3 10.0 = 1408.8 kN
Water uplift = -9.81 0.48 2.3 10.0 = -108.3 kN

Total = 1981.45 kN

Lateral Load:
Fx (from Column) = 116.0 3 = 348.0 kN

Active Pressure:
Surchage (1) = 0.29 20 3.0 = 17.7 kN/m
1 2
Soil (2) = 0.29 19 3.0 = 25.2 kN/m
2

Soil (3) = 0.29 19 2.52 0.48 = 6.8 kN/m

1 2
Soil (4) = 0.29 9.19 0.48 = 0.31 kN/m
2

Total = 49.98 kN/m 10.0

= 499.8 kN

Pasive Pressure:
1 2
Soil (5) = 3.39 19 2.02 = 131.5 kN/m
2

Soil (6) = 3.39 19 2.02 0.48 = 62.5 kN/m

1 2
Soil (7) = 3.39 9.19 0.48 = 3.6 kN/m
2
1
Total = 197.6 kN/m 10.0
2
(FOS)
= 987.9 kN

Check Sliding

Total Lateral Force = 348.0 + 499.8 = 847.8 kN


2
Total Restoring Force = 1981.4 tan ( 33 ) + 987.9 = 1788.4 kN
3

Factor of Safety 1788.4 (O.K.)


= = 2.11 > 1.50
(for Sliding) 847.8