Sunteți pe pagina 1din 2

Limited Warranty Coverage Regulatory information

Cleankeys Inc. warrants the Cleankeys keyboard to be free from


malfunctions and defects in both materials and workmanship for two European Union Directives Conformance Statement
years from the date of purchase. Retain the original dated sales re- This device complies with the essential requirements and other
ceipt. Proof of the date of purchase will be required with any request relevant provisions of directive 2004/108/EC.
for warranty repair. Warranty service is only available from within FCC Rules – Part 15
the country where Cleankeys was originally purchased. You may be Keyboard FCC registration number: XWS-CKPXXW
required to ship Cleankeys, at your expense, to the authorized ser- Wireless Receiver FCC registration number: XWS-CKD
vice facility designated by Cleankeys Inc. Cleankeys Inc. will repair This device complies with Part 15 of the FCC Rules. Operation is
or replace your Cleankeys if it fails to function properly during the subject to the following two conditions: (1) This device may not cause
warranty period, subject to any conditions and/or limitations stated harmful interference, and (2) this device must accept any interference
herein. Warranty service will include all labor as well as any necessary received, including interference that may cause undesired operation.
adjustments and/or replacement parts. If Cleankeys Inc. is unable to
repair or replace your Cleankeys, Cleankeys Inc. will, at its option, Industry Canada (IC) Notice

Wireless Keyboard
refund the purchase price paid for your Cleankeys provided it has This Class B digital apparatus complies with Canadian ICES-003.
been returned to Cleankeys Inc. along with proof of purchase price Cet appareil numérique de la classe B est conforme à la norme
paid. Repair, replacement, or refund of the purchase price are the sole NMB-003 du Canada.
Keyboard Certification Number IC: 8721A-CKPXXW

Quick Reference
remedies under the warranty. If replacement parts are used in making
repairs, those parts may be remanufactured, or may contain remanu- Wireless Receiver Certification Number IC: 8721A-CKD
factured materials. If it is necessary to replace the entire Cleankeys, WARNING
it may be replaced with a remanufactured Cleankeys. Remanufactured Changes or modifications to this equipment not approved by

Card
Cleankeys, parts and materials are warranted for the remaining war- Cleankeys Inc. can cause this equipment to not comply with
ranty term of the original Cleankeys, or 90 days after the date of Part 15 of the FCC rules and void the user’s authority to operate this
repair or replacement, whichever is longer. equipment.

Limitations Specifications
This warranty does not cover circumstances beyond Cleankeys Inc.
Keyboard Size: 14.68” x 5.64” x 0.91” (373mm x 143mm x 23mm)
control. This warranty does not apply when failure is due to shipping
Wireless Receiver Size: 1.89” x 0.68” x 0.35” (48.0mm x 17.3mm x
damage, accident, alteration, modification, unauthorized service,
8.9mm)
misuse, abuse, dropping, failure to follow Cleankeys Inc. operation,
Keyboard Weight: Glass: 2.0 lbs (0.91 kg), Acrylic: 1.6 lbs (0.73 kg)
maintenance or repacking instructions, or claims made after the
Wireless Receiver Weight: 0.21 oz (6 gr)
duration of this warranty. Cleankeys Inc. makes no other express or
Color: White
implied warranty for this product, and disclaims the implied warran-
Cable: 6.8 ft. (2.0m)
ties of merchantability and fitness for a particular purpose. In the
Interface: 2.4 GHz wireless radio
event that the exclusion of any implied warranty is ineffective under
Keyboard (Charging) Power: 5V @ 1A (max)
the law, the duration of the implied warranty will be one year from the
Wireless Receiver Power: 5V @ 22mA
purchase date or such longer period as required by law. The option
Supported operating systems: Windows®, Mac, Linux, Unix
of repair, replacement, or refund is Cleankeys Inc. only obligation.
Regulatory approvals: FCC, CE, ROHS
Cleankeys Inc. will not be responsible for any special, consequential
Mounting option: Three #6-32 inserts spaced in a MIS-D 75 Vesa
or incidental damages resulting from the sale, purchase, or use of this
standard pattern
product regardless of the cause. Liability for any special, consequential
Operating Environment: 41º F (5º C) to 95º F (32º C)
or incidental damages (including but not limited to loss of revenue or
Warranty: Two year (extended options available)
profit, downtime costs, loss of the use of the equipment, cost of sub-
stitute equipment, facilities or services, or claims of your customers
for such damages resulting from the purchase, use, or failure of your References
Cleankeys), regardless of cause or for breach of any written or implied For more information about your new Cleankeys keyboard, go to the
warranty is expressly disclaimed. Cleankeys web site (www.cleankeysinc.com). The web site has:
• The Cleankeys keyboard User Guide which contains more detailed
Product registration information about the Cleankeys keyboard.
• FAQs and other support information
Please go to the Cleankeys web site (www.cleankeysinc.com) and
• Contact information
register your Cleankeys keyboard.

Part number: 12515


Printed in Canada Document version: 01
1 2 3

Turning on the Cleankeys keyboard Changing the volume


1. Press the power button on the keyboard. 1. Hold fn and touch F9 or F10.
The power LED on the keyboard turns on. The indicator LEDs light to indicate the volume
level. Five LEDs for high volume. One LED for low
Connecting the Cleankeys keyboard — 4 5 6 7 volume.
wireless 2. Hold fn and touch F9 to lower the volume or touch
1. Turn on the computer. F10 to raise the volume.
2. Plug the wireless receiver into a USB port on the To turn the volume off, hold fn and touch F9 until
computer. all five LEDs are off.
3. Wait for the computer to recognize the wireless
receiver. Pausing the Cleankeys keyboard
4. Turn on the keyboard. If the keyboard does not When the keyboard is paused, it does not send char-
turn on, the built in battery may need to be acters when the keys are touched or tapped. This
charged. allows cleaning or disinfecting the keyboard surface
5. Press the pairing button on the wireless receiver. without inadvertently typing keys.
The pairing LED on the wireless receiver begins to To pause the keyboard, hold fn and touch esc. The
flash. pause LED flashes (above the pause label) when the
6. Press the pairing button on the keyboard. The keyboard is paused. To unpause the keyboard, hold fn
pairing LED on the keyboard flashes at least once. and touch esc. The pause LED stops flashing.
When the wireless receiver and the keyboard have
Cleaning the Cleankeys keyboard
finished pairing, the pairing LEDs on the wireless
The Cleankeys keyboard is made from ABS plastic
receiver and the keyboard stop flashing.
and acrylic or glass. The Cleankeys keyboard can be
Note: You must press the pairing button on the
cleaned with anything suitable for those surfaces. For
keyboard within 10 seconds of pressing the pairing
the acrylic or glass, use a standard glass cleaner. For
button on the wireless receiver.
the ABS plastic use any standard counter-top cleaners.
7. To verify the keyboard is working, touch the caps key. The caps
Do not use abrasive cleaners.
key LED turns on if the keyboard is recognized by the computer.
The Cleankeys keyboard is splash-proof, but should not be immersed
8 9
Connecting the Cleankeys keyboard — USB cable 1 power button power LED 6 in water. Be sure to pause the keyboard before cleaning the keyboard
1. Turn on the computer. and unpause the keyboard when finished.
pairing button - indicator LEDs 7
2. Plug the smaller end of the USB cable into the USB port on the 2 keyboard Disinfecting the Cleankeys keyboard
keyboard and plug the larger end of the USB cable into a USB port pairing LED -
USB port wireless receiver 8 Refer to the Cleankeys Inc. web site for a list of recommended disin-
on the computer. 3
fectant solutions. Be sure to pause the keyboard before disinfecting
3. Turn on the keyboard. 4 battery LED pairing button -
9 the keyboard and unpause the keyboard when finished.
4. Wait for the computer to recognize the keyboard. wireless receiver
5. To verify the keyboard is working, touch the caps key. The caps pairing LED - Tap Beta Test Program
5 keyboard
key LED turns on if the keyboard is recognized by the computer. Tap sensing is being offered on the Cleankeys keyboard as a Beta test.
With touch and tap sensing, unlike just touch sensing, the keys must be
Checking the battery tapped to type characters. This not only provides a more familiar feel, it
To check the amount of charge that is left in the keyboard battery,
also allows the user to rest their fingers on the keyboard.
hold fn and touch num. The indicator LEDs light to show the current Typing on the Cleankeys keyboard To participate in the Tap Beta program, visit
battery level. Five LEDs means the battery is fully charged. One LED The keys on the Cleankeys keyboard do not move, they use touch www.cleankeysinc.com.
means the battery should be charged soon. capacitance technology to sense the touch of a human finger. Touching
a key with a pencil, for example, will not activate it. However, the Turning tap sensing on or off
Charging the battery When tap sensing is turned on, the desired key must be tapped to type,
Cleankeys keyboard can be used with surgical gloves, or any gloves.
Charge the battery by connecting the keyboard to the charger or a USB
Just change the sensitivity accordingly. not just touched. When tap sensing is turned off, the Cleankeys keyboard
port on the computer.
Note: Resting a finger on a key will cause that character to be typed uses only touch sensing to sense a keystroke.
1. Plug the charger into a wall outlet.
continuously until the finger is removed. If tap sensing is off, do not rest fingers on the keyboard as it acts as a
2. Plug the wide end of the USB cable into the charger and plug the
touch sensing keyboard.
small end of the USB cable into the USB port on the keyboard. Changing the sensitivity 1. Touch and hold fn. The LED above tap on/off shows the current state
When the battery is charging, the amber battery LED is lit. 1. Hold fn and touch F11 or F12. of tap sensing.
When the battery is fully charged, the green battery LED is lit. The indicator LEDs light to indicate the sensitivity level. Five LEDs If the LED is off, tap sensing is off. If the LED is on, tap sensing is on.
for high sensitivity. One LED for low sensitivity. 2. To change the current state of tap sensing (either on to off or off to
Mounting
2. Hold fn and touch F11 to lower the sensitivity level. on), hold fn and touch F8.
The keyboard may be placed on a counter top or mounted to a wall or
Hold fn and touch F12 to raise the sensitivity level.
bracket. There are three #6-32 mounting inserts on the bottom of key-
Note: Sensitivity cannot be turned off.
board. These inserts are compatible with the MIS-D TS VESA standard
pattern. Using these mounting inserts, the keyboard may be mounted
at any angle, including vertical.

S-ar putea să vă placă și