1: SDCCH Sucess Rate
SDCCH Success Rate Analysis-Nokia System-1
Possible :
Data Collection :
Co or Adjacent BCCH
High TCH Blocking on target cell
Wrong TSC setting regarding BSIC allocation
Bad Neighbor Relation
HW faulty or Unbalance TRX power among a sector
Others ( Inter BSC-Inter MSC)
Preparation Data :
1.
Preparation Data :
- BCCH Planning, ND report 072 (DL Interference distribution)
- ND Report 216, 196 and Alarm (Interference)
- ND Report 204, 153, 195 ( HO fail and Path Balance)
- ND Report 232 ( Coverage cell)
- ND Report 163 or TQM drop per causes
KPI Analysis on Nokia system-TCH drop-2
Problem Analysis:
1. Check possibility Co. or Adj. Interference. Check clean BCCH frequency.
2. Check DL quality Distribution and Check MAL and MAIO
3. Check UL quality Distribution, check UL interference Pwr Contrl setting to
compensate interference.
4. Check % of HO fail from adjacencies, focused on High HO Fail. Check
TCH_RF_HO_OLD. Check possibility to add some neighbor. Try to prevent un proper
HO and use FMT to reduce drop.
5. Check best serving cell, possibility HO to best serving cell (Macro or Indoor) make it
faster to prevent drop.
6. Check TRX alarm (mostly 7745 together with 7743 or 7746). Check TRX configuration
or reset TRX if needed.
7. Check TA distribution, coverage spillage and proposed physical tune.
8. Check and compare which one the highest: Fail on RADIO, ABIS, A_IF, TR or LAPD.
Tips Pengoptimalan untuk Nokia Sistem
2: HOSR Analisis
Analisis HOSR-Tips Nokia sistem-1
Kemungkinan:
Kemungkinan:
- Interferensi pada BCCH TRX
- Interferensi pada hopping TRX (DL Interference)
- Eksternal Interferensi (gangguan UL)
- Hubungan Sesama Buruk (HO buruk)
- Cakupan Rendah
- HW Rusak atau TRX Daya Ketidakseimbangan
- Lain-lain: A_If, TR atau LAPD Gagal
Beberapa nomor Laporan Penting untuk sistem Nokia untuk menganalisis drop TCH:
Persiapan Data:
- BCCH Perencanaan, ND laporan 072 (DL distribusi Interference)
- Laporan ND 216, 196 dan Alarm (Interference)
- Laporan ND 204, 153, 195 (HO gagal dan Saldo Path)
- Laporan ND 232 (sel Cakupan)
- ND Laporan penurunan 163 atau TQM per menyebabkan