Technical Manual
Volume I
EQUIPMENT DESCRIPTION
MOPIENS, Inc.
www.mopiens.com
Table of Contents
3.3. CMA................................................................................................................3-20
3.3.1. Appearance of CMA ........................................................................................... 3-20
3.3.2. CMA Block Diagram ............................................................................................ 3-23
3.3.3. Major CMA Parts ................................................................................................. 3-24
3.3.4. Operations of Frequency Synthesis Circuit (SYN) ............................................. 3-25
3.3.5. Modulator (MOD) ................................................................................................ 3-26
3.3.6. Carrier Power Amplifier (CPA) ............................................................................ 3-28
3.3.7. Other Circuits ...................................................................................................... 3-29
3.7. MSG................................................................................................................3-71
3.7.1. Appearance of MSG ........................................................................................... 3-71
3.7.2. Features of MSG ................................................................................................ 3-72
3.7.3. Main Parts of MSG ............................................................................................. 3-73
3.7.4. Microprocessor and Peripheral Circuits .............................................................. 3-73
3.7.5. Modulation Signal Generation for Carrier Wave ................................................. 3-74
3.7.6. Modulation Signal Generation for Sideband ....................................................... 3-77
3.7.7. Switching Signal Generation for Antenna ........................................................... 3-79
3.7.8. RF Phase Control ............................................................................................... 3-83
3.7.9. Other Control and Monitor .................................................................................. 3-84
Contents of Figures
Figure 1-1 Principles of Light Tower ...................................................................................... 1-3
Figure 1-2 Phase Relationship between Reference and Variable Phase Signals ................ 1-5
Figure 1-3 Radiation Pattern and Phase Relationship of CVOR .......................................... 1-7
Figure 1-4 The Frequency Spectrum of VOR Signal ............................................................ 1-8
Figure 1-5 Frequency Deviation by Doppler Effect ............................................................. 1-11
Figure 1-6 Implementing the Continuous Rotation Effect by Blending ............................... 1-12
Figure 1-7 Phase Relationship of VOR Signal .................................................................... 1-13
Figure 1-8 Configuration of the VOR Receiver ................................................................... 1-16
Figure 1-9 VOR Course Indicator ....................................................................................... 1-17
Figure 1-10 TO-FROM Indicator ............................................................................................ 1-18
Figure 1-11 Doppler Effect ..................................................................................................... 1-19
Figure 1-12 System Diagram ................................................................................................. 1-29
Figure 1-13 Sub-system of MARU 220 .................................................................................. 1-30
Figure 1-14 Unit Mounting Positions ..................................................................................... 1-31
Figure 1-15 Redundant Structure of Power Unit ................................................................... 1-34
Figure 1-16 Redundant Structure of the Transmitter ............................................................. 1-35
Figure 1-17 Redundant Structure of the Monitor ................................................................... 1-36
Figure 1-18 Classifying the Slots of CMS Units ..................................................................... 1-37
Figure 2-1 External View of ASU........................................................................................... 2-1
Figure 2-2 Installation Position and Appearance of PDC ...................................................... 2-1
Figure 2-3 AES Configuration ............................................................................................... 2-3
Figure 2-4 Installation locations and appearance of each MAS LRU ................................... 2-4
Figure 2-5 MAS Configuration & Interfaces .......................................................................... 2-6
Figure 2-6 Installation Positions and Appearance of Each CMS LRU .................................. 2-7
Figure 2-7 CMS Configuration & Interfaces ........................................................................ 2-10
Figure 2-8 Each LRU Installation Position and Appearance of PSS................................... 2-12
Figure 2-9 PSS Configuration & Interfaces ......................................................................... 2-14
Figure 2-10 FAN Installation Positions and Appearance ....................................................... 2-15
Figure 2-11 Positions and Appearance of Air Baffle .............................................................. 2-15
Figure 3-1 Appearance of ASU ............................................................................................. 3-1
Figure 3-2 ASU Configuration & Interfaces........................................................................... 3-2
Figure 3-3 Internal Configuration of ASU .............................................................................. 3-3
Figure 3-4 Internal Configuration of ASU-TM........................................................................ 3-5
Figure 3-5 Configuration of SIN Path .................................................................................... 3-6
Figure 3-6 Configuration of COS Path .................................................................................. 3-6
Figure 3-7 Internal Configuration of ASU-SM ....................................................................... 3-8
Figure 3-8 Antenna Selection Signal Decoding .................................................................... 3-9
Figure 3-9 Switching Signals and Antenna Selections ....................................................... 3-10
Figure 3-10 Timings of the COS Antenna Switching Signals ................................................ 3-11
Figure 3-11 Timings of the SIN Antenna Switching Signals .................................................. 3-12
Figure 3-12 The Front Panel of PDC ..................................................................................... 3-13
Contents of Tables
Table 3-1 Test Signals Outputted from TSG .......................................................................... 3-68
Abbreviations
ADC Analog to Digital Converter
AES Antenna Electronics Subsystem
AMP Amplifier
ANT Antenna
ASU Antenna Switching Unit
BIT Built In Test
BITE Built In Test Equipment
BPF Band Pass Filter
CMA Carrier Modulation Amplifier
CMS Control Monitor Subsystem
CPA Carrier Power Amplifier
CPD Carrier Power Detector
CSP Control and Status Panel
CSU Control Selection Unit
CVOR Conventional VOR
DAC Digital to Analog Converter
DET Detector
DME Distance Measuring Equipment
DPDT Double-Pole Double-Throw
DVOR Doppler VOR
ENV Envelope
GUI Graphic User Interface
LCU Local Control Unit
LPF Low Pass Filter
LSB Lower Sideband
MAS Modulation Amplifier Subsystem
MOD Modulator
MISC MISCellaneous
MMIC Monolithic Microwave Integrated Circuit
MOD Modulator
MON Monitor
MSG Modulation Signal Generator
PA Power Amplifier
PDC Power Detector &Changeover
PFC Phase Frequency Comparator
PLD Programmable Logic Device
PLL Phase Locked Loop
PSS Power Supply Subsystem
PSU Power Supply Unit
PWM Pulse-Width Modulation
RCMU Remote Control and Monitor Unit
NDB refers to the navigation aid facility that becomes the barometer that informs the
location and azimuth of the NDB station to an aircraft by transmitting a non-directional
radio wave.
NDB has been the facility used in the air and sea for the longest time as for a simple system
Configuration. NDB is the facility for detecting the azimuth of an NDB terrestrial station
equipped with the Automatic Direction Finder (ADF) by transmitting the non-directional
radio waves in the medium/long-frequency range (200~415kHz).
The accuracy of NDB is in the range of 5~10.
The Instrument Landing System (ILS) guides aircrafts with directional radio waves so that
they can follow a certain course and land accurately even in the nighttime or when the
visibility is bad. ICAO adopted ILS as a standard for the precision approach support system
in 1950.
The Distance Measuring Equipment (DME) is the system that provides information to the
aircraft for the slant distance between the terrestrial equipments. Generally, it is operated in
collocation with VOR.
If the DME interrogator mounted onto an aircraft transmits the pulse signal to the terrestrial
station, the DME terrestrial station receives this signal and then transmits the response
signal to the aircraft after a certain delay time (50s). The time interval between
interrogation pulse and response pulse is proportional to the slant distance between the
aircraft and the terrestrial DME facility. The DME interrogator calculates the distance by
measuring the pulse signal exchange time.
The ultra short wave VOR is the aid facility that supports aircrafts to approach an airport or
to navigate a certain course by providing the azimuth information dependent on the
terrestrial wireless stations. ICAO has adopted VOR in 1949 as the standard for the non-
precision approach facility.
Aircraft can decide the azimuth based on the terrestrial wireless stations by receiving the
VOR signals. The azimuth is indicated on the indicator of VOR receiver that is mounted on
to the aircraft.
The frequencies used by VOR can be in the range of 108~118MHz. Although the effective
distance reachable by the VOR radio wave is generally limited to the visible range of
distance, it may depend on the surrounding environment, the location that VOR is installed,
and the altitude that the aircraft is flying.
It is developed for the course directions of TACAN military aircrafts. TACAN provides the
distance and azimuth information at the same time. Since the distance-measuring signal is
identical to that of DME, civil aircrafts can use TACAN as the DME. Although TACAN
can be used as a stand-alone system, the distance measuring part of TACAN is collocated
within TACAN and VOR so that civil aircrafts can also share it.
To aid understanding the basic principles of VOR, lets assume tow virtual light towers of
using two lights. Let say that one of two lights, referred as Reference Signal, is a white
light fixed at one location and can observe all the directions around. The other is a rotating
green light that flashes the light only in one direction and the observer can see the light
only when he is at the right direction. Lets us call it as Variable Signal.
1) The reference signal (white light) lights up only when the variable signal (green light)
face exactly to the magnetic north.
2) The variable signal rotates at a fixed rate and flashes only in one direction.
Lets assume that it takes 60 seconds for the variable signal to make a turn of 360 and the
reference signal (white light) flashes when the variable signal faces to the magnetic north.
By measuring the time between the observations of reference signal and variable signal, the
azimuth of current location can be calculated.
N N N
Green Light
(Variable Signal)
120
In this case, the observers azimuth at the magnetic north from the
light tower can be calculated as 6 20sec = 120.
In this case, the observers azimuth at the magnetic north from the
light tower can be calculated as 6 52sec = 312.
The signals identical to the reference and variable signals mentioned in the azimuth
principles are used in the actual VOR. The only difference is that these two signals are
radiated to the wireless signals rather than lights.
The principles of VOR are based on the phase relationship between Reference Phase Signal
and Variable Phase Signal, which are two 30 Hz signals.
The reference phase signal, as a sine wave of 30 Hz, is omni-directionally radiated and the
phase of reference signal is identically observed regardless of the observers direction.
Although the variable phase signal is also a 30 Hz sine wave, it is rotated and radiated at
the rate of 30 cycles/s and the phase observed varies according to the observers position.
The VOR receiver obtains the azimuth by calculating the phase difference between these
two signals.
Figure 1-2 shows the phase relationship between two signals in the 4 directions of VOR.
The phases of two signals will be matched when it is at 0 (or magnetic north). At the 90
direction, the phase relationship will be changed and the variable signal as relative to the
reference signal will be delayed by 90.
Phase Difference = 0
0
(N)
270 90
(W) (E)
Phase Difference = 90
180
(S)
Variable Phase (AM 30Hz)
Figure 1-2 Phase Relationship between Reference and Variable Phase Signals
The actual VOR signal in addition to the two signals mentioned above includes a unique
IDENT for identifying the VOR transmitting station and optionally, it can include a voice
signal.
IDENT consists of 2~3 different alphabets or digits with the respective transmitting station
and the 1020 Hz sine wave signal whose amplitude is modulated by the carrier wave is
keyed and transmitted. The Morse code is keyed at the speed of 7 words/minute and the
identification signal is repeated at the rate of 3 or 4 times in every 30 seconds.
The voice signal as an optional item is the audio signal in the range of 300 Hz ~ 3,000 Hz,
whose amplitude is modulated by the carrier wave. The voice signal is either transmitting
the IDENT as a voice rather than a Morse code or is used for broadcasting the airport
information (ATIS).
The modulation value included in the VOR signal for each modulated signal is described as
in the following according to the ICAO Annex 10 specification.
30 Hz AM Signal: 30 %
9960 Hz Sub-carrier : 30 %
IDENT: 10 % Max.
Voice Signal: 30 % Max.
In case of the conventional VOR, the terrestrial station continuously transmits the
directional (Cardioid characteristics) VHF radio wave while rotating it at the rate of 30
cycles/s in the clockwise direction. If the receiver within an aircraft receives this signal, the
modulated signal (AM 30 Hz) can be obtained since the signal strength is varied according
to the signal strength. This signal is the variable phase signal.
Since the VOR terrestrial station is also transmitting the reference phase signal of 30 Hz at
the same time, the direction of receiving position can be known from obtaining the phase
difference by receiving these two signals simultaneously. The reference phase signal at the
conventional VOR transmits the carrier wave of 108 ~ 118 MHz by modulating the
9960 Hz sub-carrier that is frequency-modulated with 30 Hz.
Phase Difference = 0
Direction of Revolution
W E
Phase Difference = 90
Figure 1-3 represents the radiation pattern and phase relationship of reference phase signal
(dotted line) and variable phase signal (solid line), which is received respectively from the
four points of due east, due west, due south and north.
While the phase of reference phase signal as in the figure is identical at the 4 points, the
phase of variable phase signal differs by the receiving direction. In other words, the phase
difference of two signals at each point is identical to the azimuth of the point. By doing so,
the azimuth of that point can be obtained by calculating the phase difference between two
signals.
Figure 1-4 represents the frequency spectrum of VOR signal that is radiated in the air.
Carrier
AM30Hz AM30Hz
FM30Hz FM30Hz
IDENT IDENT
Voice Voice
Since each modulation element is amplitude-modulated to the primary carrier wave, the
frequency spectrum as in the figure is distributed in a horizontal symmetry of USB in the
right and LSB in the left around the carrier frequency fc.
The Morse code IDENT appears on the both points 1020 Hz away from the carrier
frequency fc and the spectrum appears on the position 300 Hz ~ 3000 Hz away from fc
when including voice signal.
Doppler VOR uses the Doppler Effect to obtain the variable phase signal.
The reference phase signals of Doppler VOR are transmitted Omni-directionally from a
fixed antenna after amplitude-modulating the 30 Hz sine wave signals on the carrier wave.
Since the antenna used in this time is non-directional, an identical signal is received in all
the directions.
The variable phase signal of Doppler VOR is transmitted by the 9960 Hz sub-carrier that
has amplitude-modulated the primary carrier wave. Actually, the sub-carrier doesnt
modulate the primary carrier wave of 9960 Hz directly, but it indirectly modulates the
amplitude of primary carrier wave that is transmitted from a separate antenna.
The 9960 Hz sub-carrier is transmitted from the sideband antenna at a fixed distance
from the sub-carrier antenna. The sideband antenna is non-directional and is continuously
rotating in the counter clockwise direction at the rate of 30 cycles/s from the sub-carrier
antenna. Therefore, the distance from a certain point to the transmission point of 9960 Hz
sub-carrier changes at the rate of 30 cycles/s.
The Doppler effect occurs since the distance between the transmitting and receiving points
varies according to the time and as the result, the receiving frequency also changes at the
rate of 30 cycles/s as well. If the sideband antenna is rotated, the frequency deviation of
30 Hz cycle occurs in the 9960 Hz sub-carrier signal by the Doppler Effect.
Ultimately, the 9960 Hz sub-carrier signal becomes one that is frequency-modulated by the
30 Hz variable phase signal. At this time, the variable phase signal from the point of
reference phase signal, which is the phase of frequency-modulated 30Hz signal, varies
according to the receiving point.
When the variable phase signal is frequency-modulated by the Doppler Effect, the
maximum frequency deviation f follows the equation below.
v f R f 2 30 R f
f
c c c
According to the ICAO Annex 10 specification, f should be 480 Hz. The rotation
radius of antenna to raise the frequency deviation of 480 Hz in a given frequency may
be calculated in the following equation.
480 c 8c 8
R
f 2 30 f
Ex) when f=113MHz, the rotation radius of the antenna can be calculated,
8 300
R 6.76m
3.14 113
Therefore, the circle diameter that the antenna rotates becomes approximately 13.52m.
Figure 1-7 represents the phase relationship for the frequency deviation (solid line) and
reference phase signal (dotted line) of the 9960 Hz sub-carrier signal received
respectively from 4 points of due north, due east, due south and due west,
which are distant from the Doppler VOR. As mentioned in the previous section, the
frequency deviation curve of 9960 Hz sub-carrier signal represents the variable phase
signal.
Although the phases of reference phase signal are identical at 4 points, as shown in the
following figure, the phases of variable phase signal vary according to the receiving point.
In other words, the phase difference between two signals at a point is the same as the
azimuth of that point. Therefore, the azimuth at a certain point can be obtained by
calculating the phase difference between two signals at any point.
Reference
Phase
1 Signal
0 t
(AM 30Hz)
1/30sec
1 f
+480Hz
0 t
N
-480Hz
1/30sec
Direction of
Revolution
D
=
4 2
2 f
16
W E +480Hz
/
0 t
-480Hz
1/30sec
S 3 f
+480Hz
0 t
-480Hz
3 1/30sec
4 f
+480Hz
0 t
-480Hz
1/30sec
There are several difficulties in rotating the antenna physically to obtain the variable signal
necessary for the Doppler type of VOR. Instead, the electrically rotating effect can be
obtained by suddenly applying electricity sequentially by arranging 48 or 50 antennas on a
fixed circle perimeter. Switching the antenna can make the sudden sequential electricity
supply. Since the rotation effect can be discontinuous only by the sequential switching of
the antenna, the blending method is used to obtain the continuous rotation effect.
A general blending signal holds the form of figure 1-6 and it can be classified by the COS
blending signal and SIN blending signal. COS blending signal is applied to the odd
numbered antenna and SIN blending signal is applied to the even numbered antenna.
COS
45 47 1 3
3 2 1 48 47
4 46
5 45
6 44 SIN
7 43 USB 44 46 48 2
8 42
9 41
t
10 40
11 39
12 38
13 37
14 36
Carrier Antenna
15 35
16 34 COS
17 33 21 23 25 27
18 32
LSB 19 31 t
20 30
21 29
22 28
23 24 25 26 27
SIN
20 22 24 26
Figure 1-7 has compared the signal phase relationship of conventional VOR and Doppler
VOR when receiving one VOR signal from two aircrafts A (90) and B (135) in two
different directions.
VOR
R-90
Aircraft A
R
-1
3
5
Aircraft B
CVOR DVOR
FM 30Hz AM 30Hz
(Reference Phase) (Reference Phase)
Aircraft
A
(R-90) 90 90
AM 30Hz FM 30Hz
(Variable Phase) (Variable Phase)
FM 30Hz AM 30Hz
(Reference Phase) (Reference Phase)
AM 30Hz FM 30Hz
(Variable Phase) (Variable Phase)
As described earlier, the reference phase signal of conventional VOR is the frequency-
modulated 30 Hz (FM 30 Hz) and the variable phase signal is the amplitude-modulated
30 Hz (AM 30 Hz). The phase in the reference phase signal from CVOR is slower than that
of the variable phase signal (as much as the azimuth of the receiving point).
The reference phase signal in the Doppler VOR is the amplitude-modulated 30 Hz (AM
30 Hz) and the variable phase signal is the frequency-modulated 30 Hz (FM 30 Hz). The
phase of the reference phase signal in DVOR is faster than that of the variable phase signal
(as much as the azimuth of the receiving point).
However, the receiver calculates the azimuth by calculating the FM 30 Hz phase from the
phase of AM 30 Hz, whether it is the reference phase signal or the variable phase signal.
Therefore, the identical azimuth is obtained from the same receiving point whether it is
DVOR or DVOR. Consequently, CVOR and DVOR can be separated from the perspective
of an aircraft and also, there is no difference in CVOR and DVOR in the perspective of
using it.
In addition to the azimuth information, VOR can be collocated with DME (Distance
Measuring Equipment) or TACAN in order to provide the distance information necessary
for the blind flying.
When providing the direction and distance information to the civil and military aircrafts,
the VOR is operated in collocation with TACAN and when the direction and distance
information is provided only for the civil aircrafts, the VOR is operated in collocation with
DME (Distance Measuring Equipment).
The location and frequency of VOR terrestrial station are marked on the radio navigation
chart. Since several VOR terrestrial station can exist in one area, a unique IDENT is
allocated to each VOR to be distinguished from each other. Also, the IDENT is indicated
on the radio navigation chart together with the VOR frequency. The VOR terrestrial station
transmits its own IDENT in a Morse code of 2~3 characters and the aircraft classifies each
VOR terrestrial station as an indicated IDENT.
The way that an actual aircraft uses a specific VOR is first to set the receiver frequency to
the VOR frequency indicated on the radio navigation chart and then to select the targeted
course (radial) by turning the handle of Omni-Bearing Selector (OBS). If it is within the
selected VOR service area, the degree and direction of the current location deviated from
the selected course is indicated on the Course Deviation Indicator (CDI). If the service
range of the aircraft is deviated, an alarm flag will be indicated on the indicator.
The VOR receiver mounted onto the aircraft follows the selected VOR frequency channel
and receives the signals from VOR.
The signal received through the antenna is demodulated into the original composite VOR
signal after passing through the circuits of the high frequency amplification, frequency
conversion, medium frequency amplification and demodulation.
Again, this signal is further classified into the AM 30 Hz signal and 9960 Hz sub-carrier
by the respective filter. The AM 30 Hz signal is separated from the composite VOR signal
by the low pass filter. The 9960 Hz sub-carrier signal is demodulated into the FM 30 Hz
signal after passing through the 9960 Hz band pass filter and FM discriminator.
Two 30 Hz signals (AM 30 Hz signal and FM 30 Hz signal) are inputted to the phase
comparator and the result is indicated on the indicator.
Navigational Signal Processing
Conventional VHF AM Receiver
9960 Hz FM30Hz
FM DET
FILTER
RF MIX IF AM DET
AM30Hz
90
30 Hz PHASE
PHASE
FILTER ADJUST
SHIFT
1 1 3 5
Frequency Selector N
3
6
Resolver Out
33
TO
30
12
Resolver Drive
15
W
24 S
OBS 21
OBS/CDI
3
N 6
33
E
TO
30
15 12
W
24 S
OBS 21
the selected radial and when that indicates FROM, it means that the aircraft is located in
the same direction as the selected radial.
1=50-90=-40=320 N
Course = R050
(OBS Setting)
B
50
CD I = 5
45
TO
225 FROM
CD I = 5
2=50+90=140
Doppler Effect, for the relative movement between the wave motion originator and
observer, refers to the phenomenon that the number of vibrations differs when they are
stopped and relatively moving. For example, when a train approaches to the observer on a
railroad track, the siren of the train will be heard high and when the train gets farther off
from each other, it will be hard low. The Doppler Effect can be found from the wave
motion and the change in the observed values of the frequency by this effect depends on
the relative velocity of the wave motion and the relative speed of the observer.
A B
fo
A B
v
fo + f
A B
-v
fo - f
received by the receiver B and A is moving at the rate of v (m/s) toward B. Then, the
frequency of the radio wave received from B can be calculated as in the following.
f 0 f 0v
f
(c v )
If A and B are moving in the opposite directions from each other, the following can be
applied.
f 0 f 0v
f
(c v )
Here, c is the speed of radio wave, which is the speed of light (3108m/s). The
frequency deviation occurred by such Doppler Effect could be summarized as in the
following.
v
f f 0 f f0
(c v )
Here, since c (the speed of radio wave) is much faster than v (the speed of a moving
object), (c v) c
Therefore, the following equation can be derived.
f fo
c
VHF communication is used for the air traffic communication, aeronautical information
service, aeronautical operation communication and operational communications for the
aircrafts within the line of light.
The frequency range used by VOR falls within the VHF frequency band of 108.000 MHz
or above and 118.000 MHz or below.
Since VHF radio wave has the straight-going nature and the diffraction as compared to
those of LF, MF and HF is relatively small, the reachable distance is wide. Due to these
characteristics, it is widely used such as for the short-distance mobile communication and
aeronautical control.
Weak Strong
Name Frequency Use
Range
VLF 3kHz~30kHz Ship
LF 30kHz~300kHz Weather broadcasting,
the navigation beacons
for ship or aircraft
MF 300kHz~3MHz Radio, amateur radio,
ship accident
communication
HF 3MHz~30MHz Amateur radio, ship
accident communication,
short-wave broadcasting Straight Diffraction
VHF 30MHz~300MHz FM broadcasting,
television broadcasting,
amateur radio,
aeronautical radio
UHF 300MHz ~3GHz Television broadcasting,
amateur radio,
aeronautical radio, radar
SHF 3GHz~30GHz Weather radar, satellite
broadcasting, space
communication
EHF 30GHz~300GHz Radar, radio wave
Strong Weak
astronomy
Compact Design
By enclosing dual transmitter, dual monitor and dual power supply in a single, standard 19
rack cabinet, its size and power consumption are minimized and the cost-effectiveness is
also accomplished.
The system can be reliably controlled or managed through the 68000 series of Motorola
microprocessor and its flexibility has been greatly improved by using EPLD to the digital
circuit part.
Plug-in type Line Replaceable Units (LRU) with card ejector are used, where applicable.
The hot-swap function is implemented to replace a LRU without turning off the system.
Self-Diagnostic Function
The Built-in Test Equipment (BITE) function is included to check integrity of the system
operation.
Item Specification
Item Specification
Sideband Specification
Item Specification
Item Specification
Polarization Horizontal
Salinity 5 % 1 % @30C
Hailstone Diameter of 1 cm
Freezing Thickness of 5 cm
Item Specification
Item Specification
1.6.1. Hardware
Each sub-system consists of the following line replaceable units (LRU) or assemblies.
PDC LRU 1
AES
ASU LRU 1
CMA LRU 2
1.6.2. Antenna
One antenna unit consists of 1 antenna, 48 sideband antennas and 1 monitor antenna.
The carrier antenna is installed on the center of counterpoise and the sideband antenna is
installed at an interval of 7.5on the perimeter that is a fixed distance away around the
centre of the carrier wave antenna. Each sideband antenna is numbered in the counter
clockwise direction starting from the antenna #1 positioned on the due north to #48.
In order to monitor the transmitted signal quality, the monitor antenna is installed at the
point that is at least 80m away from the center of counterpoise.
As for the user interface equipments in monitoring and maintaining various equipments,
the Remote Maintenance Monitoring System (LMMS) and Remote Maintenance
Monitoring System (RMMS) can be considered. These systems are installed and operated
onto the IBM-compatible PC by installing the Windows 2000 or higher OS.
LMMS is connected to the system console through a serial RS-232 cable and RMMS is
connected to the system remote port through a private line or dial-up modem.
The remote control unit consists of Remote Control & Monitor Unit (RCMU) and Remote
Monitor Unit (RMU).
RCMU is made possible to display and control the status of equipments by attaching the
LED indicator, LCD and keypad. RMU only has the function of indicating the status of
equipments while not having the control function of changing the status of equipments.
The redundancy of MARU 220 system is made available to the power unit, transmitter and
monitor.
Since the output of two independent MARU 220 power units is connected in parallel, the
remaining one supplies the power necessary to the entire system when one of two power
units is not functioning. Since it is designed in such a load sharing structure, there exists
neither a physical switching process nor a power interruption state.
Backup
Battery#1
AC/DC DC/DC
Converter#1 Converter#1
220VAC DC
Input Output
AC/DC DC/DC
Converter#2 Converter#2
Backup
Battery#2
The transmitter unit of MARU 220 is duplicated in a way that transmits the output of two
independent transmitters through one selected by the switch and the other added to the
dummy load to emit by heat.
If a problem occurs from the transmitter connected to the antenna, the monitor detects it
and sends a command to switch over the converter. If this command is executed, the output
of current standby transmitter is switched over to the antenna and the transmitter output
previously connected with an antenna is switched to the dummy load. It is done in the way
of shifting the roles of active and passive (standby) transmitters.
It can be classified into the types of Hot Standby and Cold Standby according to the
standby transmitter operation and one type can be selected according to the system setting.
In case of the Hot Standby type, 100% of the standby transmitter output continues to be
outputted to the dummy load. In case of the Cold Standby, it turns off the transmitter output
when in the standby mode and the output is emitted when switched to the active mode.
Transmitter ANT
Transmitter#1 Switch
(Active)
Transmitter#2
Dummy load
(Standby)
Transmitter#2
Dummy load
(Active)
Monitor Redundancy
MARU 220 uses two independent monitors and they receive, analyse and checks the
signals emitted to the air in the current system. The signal inputted to the monitor is
received from one common antenna and is distributed to two monitors. As an option, they
can be independently supplied to two monitors by using two antennas.
DVOR System
Monitor#1
Monitor Antenna
(Active)
Monitor#2 Distributor
(Standby)
The operation status of the system can be judged by using the results of two redundant
monitors and it may effect on the system operation according to the result selection when
two different outputs are made from two separate monitors.
MARU 220 requires user to selectively use one of two modes AND and OR when
judging an error from the analysis results of two monitors.
The AND mode is the method of judging an error when the signal analysed by both
monitors is found to be erroneous and the OR mode regards it an error when either one
of them is found to be erroneous.
Each unit of MARU 220 should be installed in the correct area since the installable area is
fixed respectively. If one is installed in a different area, it may cause a permanent damage
to the circuit. In order to prevent this risk fundamentally, the CMS and MAS units are
designed as in the following.
MAS (SMA, CMA): Since the sizes of SMA and CMA are significantly different from
each other, it is almost impossible to insert into other positions. It will not make any
problem since SMAs are compatible with each other.
CMS (MON, MSG, CSU, and LCU): Since the connector locations connected to the
back-plane are different from each other, the units corresponding to the locations can
be mounted.
As shown on the figure below, since the connector locations are differently designed for
each slot, it is impossible to mount another unit on a specific slot. The same type of units
can be mounted in any slot.
For example, the MON unit can be attached either in the MON #1 slot or in the MON #2
slot. On the other hand, the MON unit cant be attached to the MSG and CSU slots since
the connector positions are designed to be different.
96P
96P 96P 144P 96P 96P
96P
96P 96P 96P 96P 96P
AES (Antenna Electronics Subsystem) consists of ASU and PDC units. PDC is installed in
a cabinet and ASU is installed within the equipment room as a separate structure.
2.1.2. Function
ASU switches 4 sideband outputs (USB SIN, USB COS, LSB SIN, and LSB COS) from
PDC and distributes to 48 antennas.
ASU basically consists of an RF switch that accommodates 4 inputs and 48 outputs. The
control signal of this switch is generated from MSG and supplied to ASU via CSU.
AUS, different from other units, is not included in the main cabinet and is separately
installed in the outside.
PDC plays the roles of changing over the transmitter connected to the antenna and of
sampling the RF output level.
PDC includes an RF relay that allows selects and changing over the output from two
transmitters TX1 and TX2. By using this relay, one output of two transmitters is connected
to the antenna and the other output is connected to the dummy load.
Also, PDC samples the RF signals from each course (CAR, USB SIN, USB COS, LSB SIN,
and LSB COS), detects their magnitude and monitors the status of the antenna.
1) ASU
ASU is positioned between PDC and sideband antenna for the RF signal flow.
The RF signal inputs of ASU are the 4 sideband signals (LSB COS, LSB SIN, USB
COS, USB SIN) provided by PDC.
The RF signal outputs of ASU are the 48 signals distributed to the respective sideband
antennas.
The switching control signal and power of ASU is provided by the CSP.
2) PDC
PDC is located between MAS and ASU (antenna in case of the carrier wave) for the
RF signal flow.
The RF signal inputs of PDC are the carrier wave signal and 4 sideband signals, which
are supplied from both sides of CMA and SMA.
Likewise, the RF signal outputs of PDC are the carrier signal and 4 sideband signals.
As for the carrier wave it is directly supplied to the antenna and in case of the
sideband it is supplied to ASU.
The input signal for controlling the coaxial relay operation is supplied from CSU.
The signals for the monitoring and status-control, outputted from PDC, are supplied
by MON.
PDC
CARRIER
ANT#0
USB-SIN
From USB-COS
CPD ASU
ANT#1 ANT#12
TX1 LSB-SIN
LSB-COS SPD#1 USB-SIN SM#1
MAS
ANT#13 ANT#24
SPD#2 USB-COS
CARRIER
SM#2
From USB-SIN SPD#3 LSB-SIN T
ANT#25 ANT#36
TX2 M
USB-COS LSB-COS
SPD#4 SM#3
MAS LSB-SIN
ANT#37 ANT#48
LSB-COS
ANT Fault SM#4
detector
Modulation Amplifier Subsystem (MAS) is the subsystem that is responsible for the RF
signal oscillation, modulation and power amplification.
MAS are made of the dual redundant structure that two transmitters (TX1 and TX2)
operate independently. One transmitter includes CMA of generating the carrier wave signal,
USB SMA of generating the upper sideband signal, LSB SMA of generating the lower
sideband signal, and the cooling fan.
The locations of installing each MAS LRU are shown on the following figure 2-4.
2.2.2. Functions
The inner area of CMA is largely subdivided into three parts of SYN (Synthesizer),
MOD (Modulator) and CPA (Carrier Power Amplifier), as in the following.
SYN: Generate the carrier wave RF signals. These signals are transmitted to MOD.
MOD: Amplitude-modulate the carrier wave RF signals. The modulated signals are
transmitted to CPA.
CPA: Amplify the modulated carrier wave RF signal.
SMA generates the sideband RF signal synchronized to the reference signal received from
CMA and modulates the amplitude by using the SIN/COS blending signal supplied from
MSG. Then, it amplifies the power of modulated sideband signal.
The inner area of SMA is largely subdivided into three parts of SYN (Synthesizer),
MOD (Modulator) and SBA (Sideband Amplifier), as in the following.
1) CMA
The modulation signal input of CMA comes from the composite audio band signals.
This signal is supplied from MSG.
The main signal output of CMA comes from the amplitude-modulated carrier wave RF
signals. This signal is provided to PDC.
The control signals such as the PLL frequency setting data of CMA are supplied from
MSG.
The status monitoring and BITE signal output of CMA is supplied to MSG.
The reference frequency signal of CMA is supplied to SMA.
2) SMA
The modulation signal input of SMA comes from the audio band blending signals.
This signal is supplied from MSG
The main signal output of CMA comes from the amplitude-modulated sideband RF
signals. This signal is provided to PDC.
The control signals such as the PLL frequency setting data of SMA are supplied from
MSG.
The reference frequency signal applied to the SMA PLL is supplied from CMA.
COMPOSITE
MOD
CMS (Control & Monitor Subsystem) generates each modulation signal and timing signal
and supplies them to MAS and AES, monitors the system operation status and transmission
signal quality, and controls the functions of each system component.
Figure 2-6 indicates the CMS position within the system cabinet and the respective unit
positions within the CMS rack.
2.3.2. Functions
LCU delivers the operators control commands to MSG and MON and returns the status
information received from MSG and MON to the operator.
Operator exchanges the control commands and status information through RMMS, LMMS,
RCMU and CSP.
The basic functions of MSG can be summarized by generating the modulation and antenna
switching signals and by controlling the transmitters.
Generate the composite signals of 30 Hz reference phase signals, IDENT and voice,
which are the modulation signals for the carrier wave.
Generate the SIN and COS blending signals, which are the modulation signals for the
sideband.
Generate the control signals for antenna switching.
Set the SYN oscillating frequencies within CMA and SMA.
Set the transmission output by controlling the amplitudes of carrier wave and sideband
modulation signals.
Control the phases of RF signal being transmitted.
MON (Monitor)
MON monitors the radiated signals and detects error. When the controlled level of signals
is not transmitted, it issues a warning and switches over to the standby transmitter to carry
out the recovery. If the signals are not recovered even after switching to the standby
transmitter, the transmission will be stopped.
CSU, as one of the parts that cannot be included in the system redundancy, holds the
following functions.
CSP, which is attached to the front panel, is the input/output device for indicating the
system status and for taking the control input. A graphic LCD, 12 LED indicators and 7
input keys are included within CSP. CSP, which is connected to the I/O bus of the CPU
inside of LCU, is directly controlled by LCU.
#2
#1
Direct cable
LMMS RS232
RS232 Monitor signal
MON
Dial-up/leased line
RMMS MODEM
Dial-up/leased line
RCMU Composite
MODEM
RS232
LCU MSG SIN To MAS
RS485
COS
DME/TACAN
CMS backplane, in addition to the connectors, includes the 4K-byte capacity of nonvolatile
memory that can be used for the storage of following common system data.
IDENT
Transmission frequency
Carrier wave and sideband output level
The modulation depth for each signal element
The permissible range for each signal parameter that is monitored by MON
Output Power Lookup Table
Monitor correction value
Other system configuration information
The common system memory is the EEPROM of using a 2-line serial interface. In this
EEPROM, the respective MSG and MON of TX1 and TX2 are used together. Since one
EEPROM is commonly used by several units, it may cause a problem when 2 or more units
are accessed at the same time.
In order to prevent this problem, it uses one common signal line /EEPROMBUSY to
control the accesses to EEPROM. Since the status of this signal line L means that other
unit is using the EEPROM, it is needed to wait until the signal line status becomes H.
After converting the supplied AC power into the DC power, PSS supplies the DC voltage
and charges the backup batteries.
Figure 2-8 indicates the PSS rack position within the system cabinet and the respective
LRU positions within the PSS rack.
2.4.2. Functions
AC/DC Converter
The AC/DC converter converts the common AC220V power into the DC +28V and
supplies it to the DC/DC converter. The AC/DC converter is designed in a plug-in structure
so that it can be easily mounted or de-mounted.
An LED indicator lamp is attached to see the power status on the front panel of the AC/DC
converter. Also, the DC output current is indicated since a digital ammeter is attached.
DC/DC Converter
The DC/DC converter is provided with the DC +28V power from the AC/DC converter and
converts into the respective DC voltages (+5V, +7V, +15V, -15V, +28V) necessary for the
system. The DC/DC converter is designed in a plug-in structure same as the AC/DC
converter.
The front panel of DC/DC converter has an LED indicator lamp to see the power status.
PDU distributes the DC voltages (+5V, +7V, +15V, -15V, +28V) converted in the DC/DC
converter to every component of the system.
Since an LED indicator lamp is attached on the PDU front panel, the status of each
power can be easily perceived.
There are the test points (T/P) on the front panel of PDU so as to measure each output
voltage.
1) AC/DC Converter
AC/DC is duplicated in the shape that 2 identical units are connected in parallel. The
AC/DC input is connected to the common power. The AC/DC output is connected to
the DC/DC input, connecting to the backplane in parallel.
2) DC/DC Converter
Likewise, DC/DC is duplicated in the shape that 2 identical units are connected in
parallel. The DC/DC input is connected to the AC/DC output. Each DC/DC output is
inputted to PDU through the backplane.
3) Backup Battery
The backup battery comprises 2 sets of the nominal voltage 24V maintenance free
batteries and each battery is separately connected to both sides of the DC/DC
converter.
4) PDU
Both sides of DC/DC output are inputted to PDU and distributed to each component of
the system.
BACKUP
BATTERY
+24V
AC 220V +28V
AC/DC DC/DC TX1
+5V TX2
Mains +7V
+15V PDU MON1
Input -15V
+28V MON2
+28V
AC/DC DC/DC COM
AC 220V
+24V
BACKUP
BATTERY
2.5. Others
2.5.1. FAN
Fans, being installed to two places as below, suck in the external air and pass it through the
internal system to prevent the abnormal operation from overheating.
The internal part of Fan consists of 3 modules, which sucks in the air from the rear side of
the cabinet and sends it to the upper end. When the fan switch in PDU is turned on, it is
intended to operate permanently unless an error occurs.
Air Baffle is the sucking holes of drawing in the external air to radiate the internal air. The
air baffles are located in 3 places of MARU 220 as shown in the figure 2-11.
Ports
ASU
Side Band ANT
12
12
12
SM
12
+5V TM
+28V DC
PSU DC -24V
USB COS
LSB COS
PDC USB SIN
LSB SIN
SB Ant 1
ASU SB Ant 3
SB Ant 5
TM SM1
SB Ant 21
SB Ant 23
LSB COS
SB Ant 25
SB Ant 27
SM2 SB Ant 29
SB Ant 45
SB Ant 47
USB COS
COS Toggle
COS Toggle COS SEL[3..0]
SIN Toggle COS SEL[3..0]
RS422 SB Ant 2
COS SEL[3..0] SIN SEL[3..0]
Receiver
SIN SEL[3..0] SIN SEL[3..0] SB Ant 4
SB Ant 6
SIN Toggle SM3
SB Ant 22
SB Ant 24
LSB SIN
SB Ant 26
SB Ant 28
SM4 SB Ant 30
SB Ant 46
SB Ant 48
USB SIN
A total of 48 sideband antennas are classified into 4 groups (12 each) and are assigned to
each SM.
SM1: Odd numbered antennas from #1 to #23 (A1, A3, A5, A7, A9, A11, A13, A15,
A17, A19, A21, A23)
SM2: Odd numbered antennas from #25 to #47 (A25, A27, A29, A31, A33, A35, A37,
A39, A41, A43, A45, A47)
SM3: Even numbered antennas from #2 to #24 (A2, A4, A6, A8, A10, A12, A14, A16,
A18, A20, A22, A24)
SM4: Even numbered antennas from #26 to #48 (A26, A28, A30, A32, A34, A36, A38,
A40, A42, A44, A46, A48)
The 4 sideband antenna signals (LSB COS, LSB SIN, USB COS, USB SIN) inputted to
ASU are distributed to each sideband antenna according to the following rules.
For the odd-numbered antenna, only the COS signals are supplied to SM1 and SM2.
For the even-numbered antennas, only the SIN signals are supplied to SM3 and SM4.
Within each SM, only one sideband antenna is selected at a time.
SM1 and SM2 are always selected at the same time and the sideband signals different
from each other are exchanged. For the first 1/60 second, the LSB signal is supplied to
SM1 and the USB signal to SM2 and for the next 1/60 second, the USB signal is
supplied to SM1 and the LSB signal to SM2.
Likewise, SM1 and SM2 are always selected at the same time and the sideband signals
different from each other are exchanged at a fixed cycle. For the first 1/60 second, the
LSB signal is supplied to SM3 and the USB signal to SM4 and for the next 1/60
second, the USB signal is supplied to SM3 and the LSB signal to SM4.
According to such rules, the following control signals are supplied to ASU by each SIN and
COS to distribute 4 input signals to each sideband antenna.
Toggle Signal: The 1-bit signal supplied to TM in order to periodically swap the USB
and LSB signals inputted to SM
COS Toggle SM1 SM2 SIN Toggle SM3 SM4
0 LSB USB 0 LSB SIN USB SIN
COS COS
1 USB LSB 1 USB SIN LSB SIN
COS COS
Selection Signal: A 4-bit signal that allows selecting a specific number of antenna
within each SM
COS SEL SM1 SM2 SIN SEL SM3 SM4
0 [00002] A1 A25 0 [00002] A2 A26
1 [00012] A3 A27 1 [00012] A4 A28
2 [00102] A5 A29 2 [00102] A6 A30
3 [00112] A7 A31 3 [00112] A8 A32
4 [01002] A9 A33 4 [01002] A10 A34
5 [01012] A11 A35 5 [01012] A12 A36
6 [01102] A13 A37 6 [01102] A14 A38
7 [01112] A15 A39 7 [01112] A16 A40
8 [10002] A17 A41 8 [10002] A18 A42
9 [10012] A19 A43 9 [10012] A20 A44
10 [10102] A21 A45 10 [10102] A22 A46
11 [10112] A23 A47 11 [10112] A24 A48
12 ~ 15 x x 12 ~ 15 x x
D3
D7
D8
D4
DC +5V
D1 D6
+5V, -24V
+28V
Control Circuit
RS422 - SIN SEL A/B [3..0] Diode Bias
+5V / -24V
RS422 - COS SEL A/B [3..0]
D10 D13
RS422 - SIN Toggle A/B
RS422 - COS Toggle A/B
D9 D14
D12
D11
D15
D16
COS SEL [3..0] LSB COS USB COS
COS SEL [3..0]
+5V, -24V to SM To SM1 To SM2 +5V, -24V to SM
ASU-TM consists of the RF switch of using the PIN diode, control signal level conversion
circuit and DC bias control signal for the pin diode.
Since the control signals received from CSU are the differential signals defined according
to the RS-422 standards, they are converted into the TTL signal level within the level
conversion circuit.
According to the level converted control signals, either +5V or -24V bias voltage is
outputted from the DC bias circuit.
The RF path corresponding to this voltage is formed in the PIN diode RF switch.
D1 D3
SIN 0
D5 SIN180
D8
Hex Inverting
Schmitt trigger
SIN0
0 1 0 1 ( Output: +5 V or-24V)
Q4 Q1 +5 V : On
SIN_ Toggle signal
- 24 : Off
From CSU
SIN 180
( Output: +5 V or-24V)
Q5 Q2
U1
COS0
D13 COS180
D16
Hex Inverting
Schmitt trigger
COS0
0 1 0 1 ( Output: +5 V or-24V)
Q7 Q3 +5 V : On
COS_ Toggle signal
- 24 : Off
From CSU
COS 180
( Output: +5 V or-24V)
Q8 Q6
U2
TM Operations
ASU-TM delivers the 4 sideband signals supplied from PDC to the 4 SMs through a
toggling process.
This phrase explains about the delivery process of the 2 SIN signals from the 4 signals and
the delivery process of COS signals is skipped as it is similar to that of COS signals.
1) According to the timing signal supplied from MSG, CSU transmits the control signal for
selecting the sideband antenna pair to ASU. The level of this signal, as a differential
signal, is identical to the RS422 signal level.
2) The RS422 receiver U5 of ASU receives the control signal.
3) The signals that have passed U5 is changed to the TTL level of signals and the toggle
signal among these signals is inputted as the Schmidt trigger inverter IC U1.
4) According to the inputted TTL level, Q4 and Q1 or Q5 and Q2 outputs either +5V or -
24V and supplies the bias voltages to the D3, D4, D7, and D8 diodes.
5) When the toggle signal is 0, Q2 is toggled off as the bias voltage is not applied to Q5.
Accordingly, -24V is outputted from the Q2 collector. Contrarily when the toggle signal
is 1, +5V is outputted from the Q2 collector as Q5 and Q2 are toggle on.
6) On the other hand, the logic is toggled by the inverter U1C in the input terminal.
Therefore, the Q2 output becomes -24V if the Q1 output +5V and reversely, the Q2
output becomes +5V if the Q1 output is -24V.
7) The following table shows the RF paths and switching statuses according to the toggle
signals.
TR
Toggle RF Path Input Diode Status Output Diode Status
Output
Signal
USB LSB Q1 Q2 D1 D2 D5 D6 D3 D4 D7 D8
-
0 RFA RFB +5V ON OFF OFF ON ON OFF OFF ON
24V
-
1 RFB RFA +5V OFF ON ON OFF OFF ON ON OFF
24V
Each SM consists of the 1-input and 12-output PIN diode switch circuits. One of 12 paths
is selected according to the selected control signals. The phases of RF paths are the same
no matter what path is selected.
A0
A1 Bias, Switching,
Antenna switching Signal A2
A3 Control Circuit
+5V, -24V, GND
(from TM)
RF1
D1 D2
RF2
D4 D5
RF3
D7 D8
RF4
D10 D11
RF5
D13 D14
RF7
D19 D20
RF8
D22 D23
RF9
D25 D26
RF10
D28 D29
RF11
D31 D32
RF12
D34 D35
The on/off operations of ASU-SM switching circuit are controlled by the selection signals
supplied from CSU. The sideband antenna number selected according to the timing
generated from MSG is binary-encoded. This selection signal is separately supplied each
with 4-bits for the odd number (for COS) and 4-bits for the even number (for SIN).
ASU-SM decodes the binary-coded antenna selection signal by using the 4-to-16 binary
decoder IC U4.
S1
S2
Decoder S3
S1
S2 S4
A0
S3
S4 S5
A1 S5
U4 S6
S6
Selection Signal S7 SM Control Signal12 ea
A2 S8
From SM S9 S7
S10
A3 S11
S12 S8
4 to 6 Line S9
S10
S 1 to S12
Control Signal S11
S12
The following shows the Truth Table for the selection of signals.
A0 0 1 0 1 0 1 0 1 0 1 0 1
A1 0 0 1 1 0 0 1 1 0 0 1 1
A2 0 0 0 0 1 1 1 1 0 0 0 0
A3 0 0 0 0 0 0 0 0 1 1 1 1
The antenna selection is made by the COS and SIN antenna selection signals according to
the sequence of the following figures.
1 47 2 48 46
3 45 4
5
6
30
29 28
21 27
23 25 22 24 26
0011 7, 31 0011 8, 32
0100 9, 33 0100 10, 34
0101 11, 35 0101 12, 36
The following figure shows the timings of the toggling signals and antennal selection
signals for the COS paths.
1/30 sec
30Hz AM
0 ~ 359 deg
Variable
1/1440 sec
1/30 sec
COSINE Toggle
LSB(Low) or USB(High)
1/720 sec
1/60 sec
Antenna Switching
COS 0000 2 [ 1, 25 ]
Antenna Switching
COS 0001 2 [ 3, 27 ]
...
Antenna Switching
COS 1010 2 [ 21, 45 ]
Antenna Switching
COS 1011 2 [ 23, 47 ]
The following figure shows the toggling signals and antenna selection signals for the SIN
paths.
1/30 sec
30Hz AM
0 ~ 359 deg
Variable
1/30 sec
SINE Toggle
LSB(Low) or USB(High)
1/720 sec
1/60 sec
Antenna Switching
SIN 0000 2 [ 2, 26 ]
Antenna Switching
SIN 0001 2 [ 4, 28 ]
...
Antenna Switching
SIN 1010 2 [ 22, 46 ]
Antenna Switching
SIN 1011 2 [ 24, 48 ]
3.2. PDC
3.2.1. Appearance of PDC
LED Descriptions
Test Ports
OUTPUT
TX1/TX2 INPUT
INTERFACE
Adjust Points
Name Description
CAR Adjust the sensitivity of the circuit that detects the abnormality of carrier wave
antenna.
SIN Adjust the sensitivity of the circuit that detects the abnormality of even
numbered (SIN) sideband antenna.
COS Adjust the sensitivity of the circuit that detects the abnormality of odd numbered
(COS) sideband antenna.
PDC
TX1 CARRIER Carrier FWD/RVS CPL
Pad
Coaxial Relay Isolator LPF
To Carrier
Dummy Antenna
Load
VSWR Detector Det
PWR_DET
(To MSG/MON1,2)
TX2 CARRIER Comparator Pad
VSWR Alam
(To monitor1/2)
TL082
Det Pad
Carrier
TX1 USB-COS
Isolator
Relay LPF
To ASU
Dummy
Load VSWR Detector Det
PWR_DET
(To MSG)
S/B FWD CPL
Comparator
VSWR Alam
TX2 USB-COS (To monitor1/2)
TL082
AMP AM1
Det
RF
Sidebnad 10KHz
(To MSG) IF
TX1 LSB-COS
Isolator
Relay LPF
To ASU
Dummy
Load Det
PWR_DET
(To MSG)
S/B FWD CPL
TX2 LSB-COS
PWR_DET
AMP AM1
Det
RF
Sidebnad 10KHz
(To MSG) IF
TX1 USB-COS
Isolator
Relay LPF
To ASU
Dummy
Load VSWR Detector Det
PWR_DET
(To MSG)
S/B FWD CPL
Comparator
VSWR Alam
TX2 USB-COS (To monitor1/2)
TL082
AMP AM1
Det
RF
Sidebnad 10KHz
(To MSG) IF
TX1 LSB-COS
Isolator
Relay LPF
To ASU
Dummy
Load Det
PWR_DET
(To MSG)
S/B FWD CPL
TX2 LSB-COS
PWR_DET
AMP AM1
Det
RF
Sidebnad 10KHz
(To MSG) IF
3.2.4. PDC-CAR
Non-Selected Signal
Dummy from DPDT Switch
DPDT RF Switch Load
CAR 2 ( TX2) FWD/RVS CPL
1 . OUT CPD
2 . TX2 35 dB CPL
1 2 3 . TX1 LPF
3 4 4 . TERM
CAR 1 ( TX1) To Carrier Antenna
U6
In
1) The carrier wave signals generated on each CMA of two TXs (TX1 and TX2) is supplied
respectively to the CAR input connectors.
2) One of two carrier wave signals is sent to the isolator passing through the coaxial relay
and the other one is sent to the external high power dummy load. The coaxial relay
operates in the double-pole double-throw (DPDT) method to exchange these signal
paths.
3) The signals that have passed through the isolator are sent to the carrier power detector
(CPD). Isolator only allows the traveling wave passing through while removing the
reflective wave.
4) The carrier wave signals sent to CPD are sent to the antenna after passing through the
35dB dual directional coupler and low pass filter circuit.
5) One pair (forward and reverse) of the signals sampled from the coupler is supplied to the
test port on the front panel of PDC.
6) Another pair of the signals sampled from the coupler is converted to the DC signal after
passing through the RMS detectors U6 and U15 and is outputted as a maximum of 5V
DC via the OP AMP buffer U1 (FWD DET and RVS DET in the above figure).
7) The FWD DET and RVS DET signals are sent to MSG and MON through the IF board.
The FWD DET signal is used to measure the carrier wave output level and the RVS
DET signal is used to detect the antenna problem.
3.2.5. PDC-SB
Sideband
Isolator
In Out
LPF 30 dB CPL
SB1 (TX1) RY1
Output
RVS DET
U2 U8 U3-B
U5
SB2 (TX2) RY2
10 KHz Signal
U6 U7
50 ohm
Term1 Term
U1 FWD CPL
FWD DET
U3-A
1) The sideband signals generated on each SMA of two TXs (TX1 and TX2) is supplied
respectively to the back plane of PDC.
2) One of two sideband signals is sent to the isolator passing through the HF relays RY1
and RY2 and the other one is sent to the internal small power dummy load. Two RF
relays RY1 and RY2 constructs a switch of using the double-pole double-throw (DPDT)
method to exchange these signal paths.
3) The sideband signals that have passed through the isolator are sent to the sideband power
detector (SPD). Isolator only allows the traveling wave passing through while removing
the reflective wave.
4) The sideband signals sent to SPD are sent to ASU via LPF.
5) The reflective wave signals sampled from the coupler RVS port are amplified on the
MMIC AMP U8 and converted to the DC level on the RMS detector IC U2. The DC-
converted signals are sent to the abnormal antenna detection circuit via the OP-AMP
buffer U3B. The abnormal antenna detection circuit compares the level of this reflective
wave signal with the pre-defined reference value and checks the status of sideband
antenna.
6) The traveling wave signals sampled from the coupler FWD port are divided into two
after passing through the 2-way divider. One of two divided signals is supplied to the
test port on the front panel of PDC. The other one is converted to the DC level on the
RMS detector IC U1. The signals converted to DC are outputted via the OP AMP U3A
(FWD DET in the above figure).
7) These signals are sent to MSG and MON via the IF board and used to measure the
sideband output level.
The status of an antenna can be checked by converting each reflective wave signal sampled
from the 3 paths of CAR, USB COS and USB SIN into DC while using the coupler within
PDC and by comparing this DC level with the reference voltage while using a voltage
comparator. Carrier wave divides the FWD DET voltage to use it as the reference voltage
and sideband divides the fixed DC voltage to use it as the reference voltage.
The abnormal antenna detection circuit is constructed on the respective I/F (interface) and
ADJ (adjust) boards as in the below.
I/F board: Include the voltage comparator IC and output level conversion circuit.
ADJ board: Include the potentiometer that can vary the voltage applied to the
comparator by dividing the reference voltage and the LED indicator circuit that
indicates the antenna status.
The potentiometer on the ADJ board should be adjusted so that it turns off the LED when
connected to the antenna with the VSWR 1.5:1 or below.
Directional Coupler
RF
RF INPUT
OUTPUT
F R
Detector
PWR Meas.
Comparator
Pad
ANT
FAULT
Detector Pad
3.3. CMA
3.3.1. Appearance of CMA
Port
Input/Output Port
Ref. CMA
Amplitude Modulation Circuit
To MON
Prescaler 1.5Vpp
PAD
SYN PLL Module
LC LPF AM1
+8 dBm
-5 dB MC12080 +10 dBm
KSP-0113E 1/N
PAD Step = 50KHz PAD fc = 120MHz Amp.
TCXO
-3 dB fc = 108~118 MHz -9 dB -1 dB +15 dB U3
20 MHz
TX C2-1.0F1 PAD 2 WAY 2 WAY
-3 dB PAD BPF AM1 PAD
+10 dBm -1 dB -3 dB fc = 113MHz Amp. To MOD
-4 dB -2 dB +15 dB -1 dB 108~118MHz
U1 U2
2 WAY 10dBm
-3 dB
F1 U4
2 WAY AM1 PAD
X1 CPL Port PAD Amp.
-3 dB -1 dB +15 dB -9 dB
108~118MHz / 0dBm
BNC PAD
-10 dB
Sideband PHASE U5
108~118MHz / +10dBm
SMA
SMA SMA
Sideband PHASE
USMA REF CLK LSMA REF CLK 108~118MHz / +10dBm
20MHz / 3 dBm 20MHz / 3 dBm SMA
Generate the reference 20 MHz clock signal by using TCXO X1. The PLL module U1
creates the carrier wave RF signal that holds the frequency range of 108 MHz~118 MHz by
using this signal. The output frequency of PLL can be set in a unit of 50 kHz.
For the frequency synchronization between CMA and both side SMAs, the 20 MHz clock
signal generated on TCXO X1 is sent to the LSB SMA and USB SMA units via the 2-way
divider. Each SMA receives this clock signal and uses it as the reference signal source of
the PLL circuit to synthesize the USB and LSB frequencies.
The output signal of the PLL module U1 is amplified by 15dB on the MMIC AMP U2 after
passing through the LPF circuit consisted of LC in order to remove the harmonic element.
The U2 output is amplified by +15dB on the MMIC Amp U4 after passing through the 2-
way divider and BPF F1. F1 is the band pass filter (BPF) that has the center frequency of
113MHz and the pass bandwidth of 10 MHz.
The output signal of U4 is divided into two parts via the 2-way divider and one of them is
sent to MOD. This is a clean carrier wave RF signal with the size of 10 dBm. The other one
is further divided into three parts via two 2-way dividers after being amplified by +15 dB
on the MMIC AMP U5. Two of these are sent to the LSB SMA and USB SMA for the
phase synchronization and the one left is outputted to the test port (BNC connector) on the
front panel for the repair/maintenance purpose.
In order to monitor the oscillating frequency of SYN, the PLL output signal is sent to the
MON unit after dividing it into 40 demultiply on the Frequency Prescaler IC U3. The MON
unit checks the output frequency of SYN by using this signal. Since the MON unit cant
count the VHF frequency directly, it transmits by dividing it into 40 demultiply without
sending the PLL output frequency in that way.
MOD +4 dBm
PAD
Phase Shifter
JSPHS-150
-2 dB
PAD
2 dBm
AM Modulation
HSMP HSMP PAD
AM1
Amp. PAD BPF
AH31
Amp. LPF
0 dB 0 dB 3814 3814 -2 dB +15 dB -2 dB -2 dB +20 dB -1 dB
PAD
-1 dB 2 WAY
From SYN U7 D1 D2 U9 F2 U10
-5 dB To CAR AMP
108~118MHz
108~118MHz
10dBm
PAD +5~+15dBm
-10 dB 0 ~ +10 dBm
5082-
PAD PAD
Amp. 2800
-4 dB TL082 Env. Det. 0 dB
U15 AM1 TL081
AM1
+15 dB Amp.
10KHz BPF PAD PAD
PAD -2 dB +15 dB -5 dB
U16 TL082 TL082 U11 D4
-2 dB U12
To CMA TP 2 WAY
108~118MHz -3 dB
0 dBm SMA U29
Phase Det. U17 U18 To CAR AMP
SYPD-2
FEEDBACK
108~118MHz
+7 dBm -5 ~ +5dBm
From MSG
0 ~ +10 dBm PAD Comp
0 dB
.
The carrier wave RF signals (108~118 MHz) from SYN is divided into three parts via the
3-way divider after inputting to MOD. Each divided signal is used in the following ways.
The 1st signal is delivered to CPA after passing through the phase adjust circuit and
modulation circuit and the filter circuit and amplification circuit. This flow is the main
RF path of MOD.
As the automatic phase adjust reference signal, the 2nd signal is applied to the phase
detector U16 input via the MMIC AMP U15.
The 3rd signal is used for checking the circuit (internal T/P).
The RF main path signal is amplitude-modulated on the PIN diode D1 and D2 after being
phase-adjusted to the Phase Shifter U7. The AM-modulated signal is filtered on the BPF F2
after being amplified by +15 dB on the MMIC U9. The BPF output signal is sent to CPA
after being amplified by +20 dB on the MMIC U10 and filtered on the LPF consisted of LC.
While the phase error may occur in the modulation or power amplification process on the
RF main path, this error can be compensated by using the automatic phase adjust circuit.
The automatic phase adjust circuit uses the Closed-Loop Control method and consists of
the phase detector U16 and phase detector U7. There are two signals within the phase
detector U16. One is the reference signal for comparison and the other is the RF signal fed
back from the CPA output. The voltage corresponding to the phase difference of two RF
signals are outputted on U16. This voltage is supplied to the Phase Shifter U7 to correct the
phase error.
The amplitude modulation process is also made by using a similar the Closed-Loop Control
method. The modulation circuit consists of the PIN diode D1 and D2. Only by this signal,
signals are greatly distorted due to the nonlinear characteristics of PIN diode. In order to
repair it, the control signal made through the feedback circuit is applied to the PIN diode
circuit rather than directly applying the modulation signal to the PIN diode circuit. The
feedback circuit consists of the Envelope detection circuit D4 and OP AMP U12. The
Envelope Detector D4 detects the carrier wave Envelope from the RF signal sampled from
the final CMA output. This Envelope signal is inputted to the comparator consisting of OP
AMP U12 and compared with the modulation signal. Here, the modulation signal is a
composite signal that is generated on MSG and supplied to CMA. The voltage
corresponding to the amplitude error is outputted on U12. This signal is inputted to the PIN
diode and used as the control signal of modulation circuit.
PA
CPA BLF248
12dB
To CAR_MOD_FEEDBACK
108~118MHz / +23~+13dBm
PAD
Balun -10 dB
-3dB Balun
-3dB Forward Power
Pre-Drv. Drv. Couple Port
PAD MRF136 PAD MRF171A
-3 dB 15dB -1 dB 16dB
U1
2 WAY
From CAR_AMP CMA OUT
108~118MHz / +5~+15dBm -3 dB -40dB
U2 (+43dBm ~ +53dBm)
Q9 Q10
Balun
-3dB Balun
-3dB
DC
ENABL
PA
E BLF248
12dB
The signal modulated from MOD is inputted to CPA. CPA consists of a 3-terminal
amplifier and its overall gain is approximately 38 dB.
The input signal is amplified by 15dB on the 1st RF driver Q9 via the -3dB attenuator. After
passing through the -1dB attenuator for matching the impedance between terminals, it is
amplified by 16dB on the 2nd amplifier Q10.
The output signal of Q10 is power-amplified on the 3rd amplifier U1 and U2. The final
power amplification is done in parallel on two amplification circuits consisted of U1 and
U2. U1 and U2, as the composite elements that are included in one package of two
MOSFETs, which are symmetric from each other, they construct their respective push-pull
amplification circuits.
Two parallel signals that have the phases differing by 180 are needed in the push-pull
amplification circuit. Since the signals outputted from the 2-way divider are the unbalanced
signals, they are converted into the balanced signals by using the Float Balun consisted of a
coaxial cable. In the same way, the amplified output is merged and outputted in the 2-way
combiner after being respectively converted into the unbalanced signals via the balance-
unbalance conversion Float Balun.
The final power-amplified signal is outputted to the external part of CMA via the -40 dB
Directional Coupler. The directional coupler is used to obtain the feedback signal necessary
for the modulation circuit.
As for the CMA power source, DC +28V, +7V, +15V and -15V are used. +28V is supplied
to the power amplification circuit of CPA. +15V and -15V are supplied to the analog circuit
such as the OP AMP. +7V is supplied simultaneously to the MMIC amplification circuit
and part of it is supplied to the rest of circuits after being converted via the 3-way terminal
constant-voltage IC.
For the On/Off control of the carrier wave output, it turns On/Off the +7V power for the
MOD MMIC amplification circuits U9, U10, U15 and U29 and the +28V power for the
respective MOSTFET Q9, Q10, Q11 and Q12 bias voltages of CPA. The On/Off control of
the power is made through using the On/Off control signal input of the Hot-Swap control
circuits U19 and U23.
The digital temperature sensor U24 is used to monitor the internal temperature of power
amplifier. The measured temperature data is sent to MSG via the 3-lined serial interface
(SPI).
3.4. SMA
3.4.1. Appearance of SMA
I/O Ports
Ports
PSU
10KHz
ALARM DATA
MON
ENABLE MOD
SIDEBAND F/D
LCU
SBA
PRESENCE
DETECTOR
SIDEBAND OUT
PDC
U4 U5 F1 U6 3 WAY
-5 dB
-10 dBm
0 dBm
AM1
10KHz BPF PAD Amp. PAD PAD
U8 -10 dB -15 dB -6 dB
TL082 +15 dB
RF
To MSG
10KHz / 5Vpp 2 WAY
LO U7 -3 dB
U9
PAD
0 dB
From CMA
Sideband PHASE CPL Port
108~118MHz 108~118MHz
+10dBm 0dBm
SMA BNC
While the CMA SYN uses the signal self-oscillated within TCXO as the reference clock,
SMA doesnt hold its built-in oscillating circuit and uses it as the reference clock of the
PLL circuit after receiving the signal generated within CMA. This is to make the output
frequencies of CMA and SMA to be exactly synchronized with each other.
The SMA SYN is programmed so that the output frequency always becomes 10kHz higher
(USB) than or lower (LSB) than the setting frequency of CMA. Hence, the carrier wave
output frequency and sideband output frequency of MARU 220 DVOR are always keeping
10 kHz intervals. Although it differs by 40 Hz from the sub-carrier center frequency of
9960 Hz that is stipulated from the ICAO Annex 10, there is no problem in its practical use
since it falls within the permissible range of below 1%, which is set by the ICAO Annex 10.
The Doppler VOR that uses Double Sideband (DSB) requires maintaining not only the
synchronization of two sideband signal frequencies but also the phase synchronization
between two signals. SMA includes the circuit for the phase synchronization. The output
signal of SMA-SYN is mixed with the output signal of CMA-SYN on the double balanced
mixer (DMB) U8 and is frequency-converted to the intermediate frequency (IF) signal of
10 kHz. Through the above process, two 10 kHz intermediate signals obtained respectively
from USB SMA and LSB SMA are sent to MSG and phase-compared from each other. If
the result differs from the reference value set previously, the control software of MSG
adjusts the voltage value applied to the phase adjusters U4 and U5 and automatically
corrects the errors.
5082-
PAD PAD
Amp. 2800
-4 dB TL082 Env. Det. 0 dB
U20 AM1 TL081
AM1
+15 dB Amp.
10KHz BPF PAD PAD
PAD -2 dB +15 dB -5 dB
U21 TL082 TL082 U15 D4
To SMA COS TP -2 dB U16
2 WAY
108~118MHz -3 dB
0 dBm U17
SMA Phase Det. U22 U23
SYPD-2 To SMA COS AMP
FEEDBACK
108~118MHz
+7 dBm +5 ~ -5dBm
From MSG
0 ~ +10 dBm PAD Comp
0 dB
5082-
PAD 2800 PAD
-4 dB Amp. TL082
U33 TL081 Env. Det. 0 dB
AM1 AM1
+15 dB Amp.
10KHz BPF PAD PAD
PAD -2 dB +15 dB -5 dB
U34 TL082 TL082 U28 D12
To SMA COS TP -2 dB U29
2 WAY
108~118MHz -3 dB
0 dBm U30
SMA Phase Det. U35 U36
SYPD-2 To SMA COS AMP
FEEDBACK
108~118MHz
+7 dBm +5 ~ -5dBm
From MSG
0 ~ +10 dBm PAD Comp
0 dB
As for the SMA modulator (MOD), the bandwidth modulation circuit constructed in the
same way is used respectively for COS and SIN. Two modulators are exactly identical and
it is the same as the one used in CMA. Hence, only the differences are described here.
Please refer to the paragraph 3.3.5 for more detailed circuit theory.
The RF signals applied to the COS and SIN modulators of SMA are exactly the same. Two
signals divided by using the 3-Way Divider from the output of SMA SYN are applied
respectively to the COS and SIN modulators. Two signals are identical in their phases and
bandwidths.
The modulation signal applied to SMA is the blending signal supplied from MSG. Blending
is used to obtain electrically the continuous rotating effects of sideband antenna and is
divided into those of SIN and COS. The sideband RF signal is amplitude-modulated near to
the modulation depth 100% by the blending signal from SMA MOD.
SBA_COS
Drv. PA
MRF136 MRF171A
+15dB +16 dB
From MOD_COS 40dB
SMA_COS OUT
108 ~ 118MHz / +5 ~ +15dBm 108 ~ 118MHz / +33 ~ +43cBm
Q9 Q10
DC Enable Feedback In
To USB_COS FEEDBACK
113.51MHz / 23 ~ 13dBm
SBA_SIN
Drv. PA
MRF136 MRF171A
+15dB +16 dB
From MOD_SIN 40dB
SMA_COS OUT
108 ~ 118MHz / +5 ~ +15dBm 108 ~ 118MHz / +33 ~ +43cBm
Q11 Q12
Feedback In
DC Enable
To USB_SIN FEEDBACK
113.51MHz / 23 ~ 13dBm
The sideband signals modulated on two MODs of COS and SIN are inputted respectively
to the COS SBA and SIN SBA. The COS SBA and SIN SBA are constructed with the
identical circuit. Hence, it is explained here only with the SBA for SIN.
SBA is constructed with a 2-way amplifier and the total gain of the respective amplifiers is
31dB. The inputted sideband RF signal is amplified by 15dB on the 1st RF driver Q11.
Then, it is amplified on the 2nd amplifier Q12 by 16dB to have its maximum signal of
+43dBm.
The final power-amplified signal is outputted to the external part of SMA via the -40 dB
Directional Coupler. The directional coupler is used to obtain the feedback signal necessary
for the modulation circuit.
As for the SMA power source, DC +28V, +7V, +15V and -15V are used. +28V is supplied
to the power amplification circuit of SBA. +15V and -15V are supplied to the analog
circuits like OP AMP. While +7V is supplied to the MMIC amplification circuit, a part of it
is converted to +5V via the 3-way terminal constant voltage IC and supplied to the rest of
circuits.
In the same way as the carrier wave, the +7V power of U13, U14, U7, U26, U27 and U30
and the gate bias +28V power of MOSFET Q9, Q10, Q11 and Q12 are controlled for the
On/Off control of sideband output. The power On/Off control is made by using the On/Off
control signal input pin of the hot-swap control circuits U19 and U23.
3.5. LCU
3.5.1. Appearance of LCU
LEDs
Switches
Name Description
RESET The switch that resets LCU CPU
Local Control Unit (LCU) is responsible for the communication interfaces among user and
the respective control/monitor units ((MSG1, MSG2, MON1, and MON2) within the
system.
User through the interfaces such as LMMS / RMMS, RCMU or CSP sends a control/query
command to LCU and LCU sends it to the corresponding MSG or MON unit. The executed
result is sent to the user in the opposite path.
The information such as the alarm detected from the system or the system parameters
collected and analyzed is also sent to LMMS/RMMS, RCMU/RMU via LCU for the
display or indicated directly on the CSP attached on the system cabinet.
The interfaces between the external devices such as LMMS / RMMS or RCMU / RMU and
the respective control/monitor units are made through the asynchronous serial data
communication. However, the CSP attached on the system cabinet is directly controlled by
LCU without going through these communication interfaces.
UART RS232 M SG 1, M SG 2
U AR T C lock : D river
14.7456M H z
ROMH
ROML
Buffer
Socket M odem 1
MPU RS232
UART
29.4912MHz
Main Clock :
SC C 1 D river
Socket M odem 2
SC C 2, SC C 3
B uffer SRAM RS232 R S 485/1, RS485/2
UART D river
FLA S H LM M S
E P LD D ATA RS232 D river
FLA S H
B uffer M O N 1, M O N 2
RS232 D river
Latch
Alarm
SPI
Status
C ontrol & Status C ontrol
C SP I/F
H ot Plug- In
FAN C ontrol C ontrol C ontrol
D ATA D ATA B uffer
M icro p ro cesso r Sink D river
Real
AD C Input Tim e
Am p C lock B uffer
Sw itching FE T
RS232 D river H ot SW A P
R TC C SP I/F C ontrol
D ata
X300
D ata D A TA A ddress
DBAuffer
TA B uffer D ata
M ain C lo ck : U 500,U 501
/C S_RO M L, H E PR O M
/RD /C S_RO M L, H E PR O M
28.4912M H z /W R /RD U 600, U 601
A ddress
E PLD /C S_FLA SH
M ic ro p ro c esso r U 400
U300
A ddress A ddress A ddress
A ddress
B uffer D ata
A ddress
B uffer B uffer
R eset Logic U 502,U 503,U 504 A ddress
U 301 SR A M
/C S_SRA M U 602
/RD
B U S B uffer /W R
M icro p ro cesso r
P erip heral Lo g ic D ata
C LKO :29.4912M H z
A ddress SR A M
/C S_FLA SH U 602
FLA SH
/RD U 603, U 604
/W R
E E PR O M
SD A , SC L U 605
M em o ry P art
S erial E E P R O M
U300 is the microprocessor for the main control of LCU. U300 is based on the M68000
core and the 1152-byte dual port RAM, programmable timer, serial communication
controller (SCC), and 24-bit general GPIO are integrated within the chip. The data and
address buses of U300 are connected to the peripheral devices through the 3-state buffer
U500-U504.
The crystal oscillating circuit X300 supplies a clock of 29.4912 MHz to U300.
U301, as the microprocessor monitor circuit IC, includes the reset signal generation circuit,
power monitor circuit and the watchdog timer. U301 supplies a reset signal to the
microprocessor U300 and at the same time, it monitors whether U300 operates normally.
The cases that U301 outputs a reset signal follow as below.
When the reset signal of U301 is outputted, the FAULT LED lamp of LCU front panel is
lighted.
Since the /RESET output signal of U301 is connected to the /OE pin of the bus switches
U1400 ~ U1408 via Q1400, the LCU input/output signal line is separated from the
backplane during the reset period.
LCU uses the following storage devices different from each other. All the rest of storage
devices except for the serial EEPROM are positioned within the memory space of the
microprocessor U300.
EPROM U600 and U601: Store the program code and data
SRAM U602: Store the temporary data used during the program execution
FLASH Memory U603 and U604: Store the log data
EEPROM U605: Store the non-volatile parameters
When the microprocessor U300 is initialized after receiving the reset signal, U300 executes
the program code saved in the EPROM U600 and U601.
U400 is a programmable logic device (PLD). It includes the logic circuits such as the
address decoder and GPIO port. The address decoder inside of U400 decodes the addresses
for each memory and I/O device and generates the Chip Selection Signals. The GPIO port
of U400 consists of the latch circuit for the output port and the digital switch circuit for the
input port.
U1105, as the Real Time Clock (RTC) IC that has built-in crystal oscillator and backup
battery, provides the standard time to the system. LCU, when saving a log data, reads the
current time from RTC IC U1105 and records the event and time of occurrence together
with the data.
UART CLOCK:
14.7456M Hz RS232 M SG1 Com m unication
Driver
Data UART U900
TXD1 TXD_LOCAL Device
RS232 Driver /CS_M SG1,2
RXD1 U1001 RXD_LO CAL U800 RS232 M SG2 Com m unication
Driver
U901
LM M S Com m unication
M icroprocessor TXD2 TXD_M O N1 M SG1/2 Com m unication
RXD2 RS232 Driver RXD_M ON1
U1000 UART CLOCK:
TXD3 TXD_M ON2 14.7456M Hz RS232 Driver U902 REM 1 Com m unication
RXD3 RXD_M ON2
M ON1/2 Com m unication Data
M O DEM 1
/CS_REM 1,2 UART
Device
Buffer U801
RS232 Driver U903 REM 2 Com m unication
EPRO M M O DEM 2
UART CLOCK:
14.7456M Hz
SRAM EPLD /CS_M SG1,2 REM 1/2 Com m unication
U400 /CS_REM 1,2
PLD CLOCK: /CS_REM 3,4
29.4912M Hz
UART CLOCK:
14.7456M Hz RS485 REM 3 Com m unication
Driver
Data UART U1002
M icroprocessor Part Peripheral Logic Device
/CS_REM 3,4
U802 RS485
REM 4 Com m unication
Driver
U1003
LCU, in addition to the 3 SCCs included in U300, has asynchronous serial communication
controllers (UART) U800, U801 and U802. Hence, a total of 9 serial communication ports
are available. The usage of each port follows as below.
U300 SCC1 is the RS-232C port exclusively for LMMS. Although the communication
speed is initially set to 57600bps, it can be changed by user. To see visually whether the
data communication between LCU and LMMS is normally made, two LED lamps are
attached on the front panel of LCU. These LEDs are lighted on whenever U300 SCC1
transmits (TxD) or receives (RxD) data.
Although the UART0 and UART1 of U801 is connected to the built-in socket MODEM,
they can interface directly to the RS-232C without using the built-in MODEM by a user
setting. In this case, set SW900 and SW901 to the RS232C position and remove the built-
in socket MODEMs U1103 and U1104. In order to use the MODEM again, set SW900 and
SW901 to the MODEM position and install the socket MODEMs U1103 and U1104.
The operation of the asynchronous serial communication controllers U800, U801 and U802
can be made by receiving the 14.7456 MHz power output from U400.
The I/O process of serial communication data is made asynchronously by using an interrupt
method. If data is received from the outside, the corresponding UART requests an interrupt
from the microprocessor U300. If the interrupt request is received, the microprocessor
U300 stops the code in execution for a moment and reads the data from UART by
executing the interrupt processing routine. The interrupt request signals are inputted
respectively to the microprocessor via the PB8 and PB9 pins of U300 for U800, via the
PB10 and PB11 pins for U801, and via the IRQ6 and IRQ7 pins for U802.
The microprocessor U300 monitors the RXRDY and TXRDY pins of each UART via U700
and U701. If one of these pins becomes the L status, the microprocessor U300 executes
reading and writing the data by judging that the corresponding UART is in the state of
receiving or transmitting.
Data C SP_DATA
Buffer
/C SP_DATA_EN U1101
BUS Signal
/C S_Sw itch Buffer C SP C ontrol Signal
C S_LED1 U1102
C S_LED2
M icroprocessor
BUS_Signal
CSP Interface
EPLD /C SP_DATA_EN
U400 /C S_Sw itch
PLD C LO C K: C S_LED1
29.4912M Hz C S_LED2
Data
Buffer C S_LED2
/C S_RTC RTC
/C S_RTC U1105
EPRO M Peripheral Logic
M icroprocessor Part
LCU directly controls the LED lamp, graphic LCD and keypad on CSP.
These devices are directly connected to the lower 8-bits D0 D7 of the CPU data bus
through the 3-state data buffer U1101.
EPLD U400 decodes the address signals of U300 and generates the respective chip
selection signals /CSLCD, /CDSWITCH, /CSLED1 and /CSLED2 for the I/O devices
included within the CSP.
The chip selection signals and other control signals from U300 is connected to CSP via the
3-state data buffer U1102.
Alarm M SG SPK1
M SG SPK2
M O NSPK1
M O NSPK2
M icroprocessor
ID Sound SPKO UT
Analog M UX Am p
U1106
Data Latch
U707
CS_CALSIG
Audio AM P
Buffer
EPRO M
If an alarm occurs from the system, LCU detects it and outputs a warning sound through
the speaker attached on CSP. LCU generates a warning sound signal of 1000 Hz by using
the Timer2 of the microprocessor U300. This signal is outputted to the TOUT2 pin of U300
and is amplified in the audio amplification IC U1107, and is played through the speaker of
CSP.
In order to check the IDENT signal being correctly transmitted, The IDENT tone generated
from MSG or the IDENT tone received via MON can be played through a speaker. The
IDENT signals coming from MSG1, MSG2, MON1 and MON2 are inputted to the Analog
MUX U1106 and one of these is outputted according to the users setting. The selected
signal is amplified in the audio amplification IC U1107 and played through the speaker on
CSP.
The magnitude of the alarm warning sound and IDENT tone, being played through the
speaker, can be adjusted by turning the volume VR1101.
3.5.8. Sub-Processor
FAN D rive
M icro p ro cesso r P eripheral Logic
U 1200 AD C 1
PSU D C Voltage & C urrent 1
Am p
FAN C ontrol
B uffer
C M A1 Tem p C ontrol
M O SI U 1200 AD C 2 Am p PSU D C Voltage & C urrent 2
C M A2 Tem p C ontrol
EPROM M ISO
AC /D C 1 Tem p C ontrol
SPI_C LK
AC /D C 2 Tem p C ontrol P SU M easurem ent
SRAM SU B -C ontroller
AVR C LO C K: U 1200
7.86432M H z U 1200 AD C 1 Tem p Source+
Am p
Tem p Source-
U 1200 AD C 2 U 1200 AD C 3
The sub-processor U1200, as an 8-bit micro-controller, has the built-in 32KB flash memory,
4KB RAM, serial communication device, timer, and 8-channel 10bit A/D converter. U1200
exchanges data through the SPI interface to the main CPU U300.
The sub-processor U1200 monitors the output voltage and current of power unit, internal
temperature, internal temperature of CMA and temperature of the equipment room and at
the same time controls the cooking FAN for the radiations of PSS and CMS.
While the respective output voltage and current of DC/DC unit is detected from the PDU
sensor and sent to LCU via the Analog MUX, it is inputted again to the ADC of U1200 via
the buffer U1201. The items measured from U1200 are shown on the following table.
The internal temperature of power unit is measured by the digital temperature sensor being
in the AC/DC unit and read from U1200 via the serial data interface.
The FAN control signal is outputted from the parallel I/O ports PD4, PD5, PD6 and PD7.
This signal operates the P-channel power MOSFET Q1100, Q1101, Q1102 and Q1103. The
gates of MOSFET Q1100, Q1101, Q1102 and Q1103 are pulled up to +28V by R1104,
R1105, R1106 and R1107. Hence when the U1100 output is off, the VGS of MOSFET
becomes 0 and the FAN stops as the drain current is cut-off. When the U1100 output is
turned on, the VGS of MOSFET rises more than 4V and the FAN operates as the drain
current flows.
The temperature measuring function inside of the equipment room is optional and it is
provided when the PT100 temperature sensor is installed within the equipment room. The
signal outputted from the temperature sensor is converted into the DC voltage via U1203
and inputted to the ADC2 of U1200 and read.
Buffer
Buffer U703
Additionally, LCU selects the test signals of TSG, monitors the attachment/detachment of
each system unit, and checks the trouble of power unit.
TSG, as the part that generates the test signal used for monitoring the operating status of
monitor, is physically included in CSU. TSG can output a total of 16 test signals. LCU
generates the 4-bit test signal selection signals via the LATCH IC U707 and provides them
to CSU.
LCU monitors the attachment/detachment status of each LRU of the system. Here, MSG
1/2, MON 1/2, CSU, CMA 1/2, LSB SMA 1/2, USB SMA 1/2, AD/DC 1/2 and DC/DC 1/2
are included. The detachment/attachment monitoring signal of each LRU is sent to the 3-
state buffer IC U704 and U705 and read by the microprocessor U300. Since each signal is
pulled up with the resistors R712 ~ R722 and R725 ~ R728, HIGH (+5V) is inputted when
no unit is attached and LOW (GND) when a unit is attached.
Also, LCU monitors the trouble of power unit. The power unit alarm signals include the
unit trouble alarm, AC input alarm and battery problem alarm. These alarm signals are sent
to the 3-state buffer IC U702 and U703 and read by the microprocessor U300.
3.6. MON
3.6.1. Appearance of MON
LEDs
Switch
Name Description
RESET The switch for resetting the LCU CPU
Ports
Signal Monitor
MON monitors the radiated signal and detects any abnormality. The radiated signal is
received with the monitor antenna and supplied to MON. MON, after amplifying and
decoding the received signal, converts into the digital data and measures each signal
parameter. The major signal parameters that the monitor watches will be followed as below.
Monitor reference azimuth
Reference 30Hz AM modulation degree
Variable 30Hz AM modulation index
9960Hz sub-carrier wave AM modulation degree
IDENT code and AM modulation degree
When the measured signal parameter goes beyond the fixed allowed range, it generates a
warning alarm. When the alarm persists for a certain period of time, it transfers to the
standby TX and tries the recovery. If the same alarm persists for a certain period of time
after transferring to the standby TX, it halts the signal transmission to prevent the wrong
signal from transmitting.
The conditions that transfers to the standby TX or halts the transmission shall be followed
as below.
When the error of monitor reference azimuth goes beyond the allowable range
When the deviation of reference 30Hz AM modulation degree goes beyond the
allowable range
When the deviation of 9960Hz sub-carrier wave AM modulation degree goes beyond
the allowable range
When the IDENT signal is omitted or the transmission is not made according to the
stipulated code or interval
When the MON unit itself has a trouble
When the deviation of variable 30Hz AM modulation index goes beyond the allowable
range
When the deviation of carrier wave frequency goes beyond the allowable range
When the carrier wave and sideband antennas have errors (VSWR > 1.2:1)
Monitor Configuration
Two MONs of MARU 220 can be configured to the OR Mode or AND Mode according to
the users selection.
OR Mode: If an alarm is detected from either one of two, it is transferred to the
standby TX or halts the transmission.
AND Mode: If alarms are detected from both MONs, it is transferred to the standby
TX or halts the transmission
Self-Diagnosis Function
It uses the Test Signal Generator (TSG) for the self-diagnosis of MON. The VOR test
signals from TSG are processed and read by MON in the same way as the signals received
from the monitor antenna. Since the VOR test signals generated from TSG are synthesized
by a digital method according to a pre-fixed number of reference modulation elements,
they are quite accurate. When a normal number is outputted after MON measures this
signal, the corresponding MON can be judged as be normal.
MON Calibration
MON is calibrated by using a standard measuring instrument before sending out from the
factory. The calibration factor is saved to the EEPROM of each MON. However, the VOR
signal parameter that MON monitors can be variable according to the setup environment
and it can differ from the actual navigation check result. The MARU 220 Doppler VOR has
the function of calibrating these differences so that the MON monitoring results can be
matched with the navigation check data. This calibration factor is saved to the system
EEPROM so that it can be retained even though the MON unit is replaced.
Others
Address
10V
Buffer EPLD Data Reference BPF AM LPF
Discriminator IDENT
1020Hz Demodulator 10Hz
Digital to Analog Converter
Microprocessor
Data
SCC
BPF FM
RS232 Limiter
9960Hz Demodulator
[LCU] MUX1 MUX2
U300 is the primary control microprocessor of MON. U300, based on the M68000 core, is
integrated with the 1152B dual port RAM, programmable timer, SCC, and 24-bit general
GPIO. The data and address buses of U300 are connected to the peripheral devices through
the 3-state buffer U500-U504.
The crystal oscillating circuit X300 supplies a clock of 18.432 MHz to U300.
U301, as the microprocessor monitor IC, includes the reset signal generation circuit, power
voltage monitoring circuit and watchdog timer circuit. U301 supplies the reset signal to the
microprocessor U300 and at the same time monitors the operation status of U300. The
followings are the cases that U301 outputs a reset signal.
When the reset signal of U301 is outputted, the FAULT LED on the front panel of MON is
lighted on.
Since the /RESET output signal of U301 is also connected to the /OE pins of bus switches
U1800 ~ U1805 via Q1800, the I/O signal line of MON is separated from the backplane
during the reset period.
MON uses several different types of storage devices as below. All the rest of storage
devices except for the serial EEPROM are positioned within the memory space of the
microprocessor U300.
When the microprocessor U300 is initialized after receiving the reset signal, U300 executes
the program code saved in the EPROM U506.
U400 is a programmable logic device (PLD). It includes the logic circuits such as the
address decoder and GPIO port.
The address decoder inside of U400 decodes the addresses for each memory and I/O device
from the address and control bus signals of U300 and generates the Chip Selection Signals.
The GPIO port of U400 consists of the latch circuit for the output port and the digital
switch circuit for the input port.
Also, U400 receives the reference clock of 7.86432 MHz from the X400 crystal oscillator,
is divided into 1/8192 and generates the 960 Hz sampling signals for A/D converter.
The serial communication port SCC1 of U300 is used to exchange the LCU status
information and control data. SCC2 is not used during a normal operation and is reserved
for debugging.
The D/A converter of MON is used to automatically adjust the gains of RF signal
processing circuit.
U700 is a 12-bit current output and multiplying D/A converter. The output of U700 is
converted into the voltage signal from the current-voltage conversion circuit consisted of
OP AMP U701. This signal is applied to the variable voltage attenuator of a RF signal
processing circuit via the non-reversal buffer consisted of U702 and Q700.
U900, as a precise reference voltage IC, supplies the 10V reference voltage to DAC U700.
The A/D converter of MON is used to sample each VOR signal element and at the same
time used to measure the carrier wave output power and power voltage.
U703 is a 13-bit (data 12-bit and sign 1-bit) parallel A/D converter. Although U703 itself is
a single channel, it is multiplexed by the analog switches IC U803, U800 and U1201 to
process several inputs.
The A/D conversion timing, when analyzing the VOR signal element, is obtained by
synchronizing it to the 960 Hz sampling signal supplied from U400. The A/D conversion is
asynchronously made to the microprocessor U300 control, when measuring the carrier
wave output and power voltage.
U703, as a precise reference voltage IC, supplies the 5V reference voltage to ADC U703.
Hot-Swap Control
U1700, U1701 and U1702 are the hot-swap ICs. These control ICs are electrically
separated from the backplane of power supply lines while in the process of attaching or
detaching a unit and prevent the unstable voltage being applied to the internal circuits of
the unit.
U1800, U1801, U1802, U1803, U1804 and U1805 are 10-bit bus switches. These bus
switches are electrically separated from the backplane of each I/O signal line while in the
process of attaching or detaching a unit and prevent the system from an erroneous
operation.
The internal RF signal processing circuit of MON filters the frequency band needed from
the RF signal received from the field monitor antenna, RF-amplifies and converts it with a
fixed level of about -5 dBm, and extracts the audio band VOR signal after detecting that.
The signal received from the antenna is supplied to the Band Pass Filter (BPF) F1101 via
the impedance matching circuit. The pass frequency band of F1101 lies in the range of 108
~ 118 MHz. The noise signals in addition to the frequency band assigned to VOR are cut-
off from F1101.
The signals that have passed BPF F1101 are supplied to the RF amplification circuit
consisted of the voltage control attenuation circuit made with the PIN diode D1100~D1105
and of the MMIC amplifiers U1100, 1101, 1102 and 1103 and are then amplified. The total
gain of RF signal processing circuit is automatically controlled by the MON software so
that -5dBm is constantly outputted for the input signal level range -45 dBm ~ +5 dBm. The
control voltage applied to the voltage attenuation control circuit has the range of 1 V ~ 8 V.
The signal amplified to -5 dBm is detected from the AM demodulation circuit U1104 and
the VOR composite signal of audio band that has removed the carrier wave is obtained.
This signal includes the DC and reference 30Hz signal proportional to the magnitude of
carrier wave, variable 30Hz signal frequency-modulated to the 9960 Hz sub-carrier wave,
and IDENT signal. The decoded VOR signal is supplied to the analog signal processing
circuit for the signal analysis by each modulation element.
The foremost one from the analog signal processing system is a signal selection switch
U1201 (MUX1). Although U1201 is the analog switch that can select one of 8 inputs, only
two of them are used here. The signals applied to U1201 are the VOR composite signal
decoded within the RF signal processing circuit and the test signal generated from the test
signal generator (TSG). U1201 is controlled by the MON software and one of these two are
selected and passed.
The signal that has passed U1201 is supplied to the 150Hz low pass filter (LPF) via the
non-reversal amplification circuit of OP AMP U1300. 150Hz LPF consists of R1305,
R1306 and MC1300 and the signal elements below 150 Hz are passed and the rest are cut-
off. Part of this signal is outputted to the test BNC connector (REF 30Hz) attached on the
front panel of MON via the OP AMP buffer U802-B.
The extracted signals pass through the 1-of-8 analog switch U800 (MUX2) and again, are
supplied to 60Hz LPF. 60Hz LPF, as an active one, consists of OP AMP U801, R826, R830,
MC801 and MC802 and allows passing the signals below 60 Hz. Therefore, only the pure
reference 30Hz signals are obtained from the VOR composite signals.
Finally, the reference 30Hz signals pass through the 1-of-16 analog switch U803 (MUX3)
and are converted into the digital data after being sampled from the A/D converter U703.
At this time, the sampling frequency is 1/ 960 second. In other words, the data is sampled
at the rate of 32 for one cycle of 30Hz signal (32 samples/cycle 960 samples/sec).
The amount of data sampled for one time of signal processing is the amount for two cycles
of 30Hz signal processing, which are 64 samples. From these, the 32 data in the back are
used in processing the Fast Fourier Transform (FFT). Since it is possible to have incorrect
data for a certain period of time until the signal is stabilized after the path corresponding to
the respective analog switches of MUX1, MUX2 and MUX3 is selected, the first 32 data
are not used.
Since the sampling frequency is 960Hz and the used data are 32, the magnitude shown in a
complex number with the respective frequency elements in the interval of 30Hz from the
range of 0 Hz (DC) ~ 480 Hz is obtained from the FFT result. By taking the DC and 30Hz
elements from these, the band modulation degree of reference 30Hz signal can be
calculated according to the equation below.
A30Hz
m30Hz
A0 Hz
Also by taking the real number part and imaginary number part of 30Hz elements, the
phase of reference 30Hz signal can be calculated according to the equation below.
Im( A30Hz )
REF arctan
Re( A30Hz )
The figure 3-43 above shows the processing steps of variable 30Hz signal.
Same as the processing steps of other analog signals, the demodulated VOR composite
signal in the RF signal process circuit and the test signal generated from the test signal
generator (TSG) are applied to U1201. U1201 is controlled by the MON software and one
of these two is selected and passed.
The signal that has passed U1201 passes through the limiter circuit consisted of D1400,
D1401 and Q1400 and the amplitude-modulated elements are removed.
This signal is filtered from the 9960 Hz band pass filter U1401 via the OP AMP buffer
U1400-A. U401, as a switched capacitor filter, receives the 491520 Hz clock signal from
U400 and constructs the band pass filter circuit below the pass bandwidth 1 kHz of the
intermediate frequency 9960 Hz.
The variable 30Hz signal frequency-modulated to the 9960 Hz sub-carrier wave via the
frequency discriminator is demodulated. Since this signal includes the unnecessary DC
elements, the pure variable 30Hz elements are extracted by using the attenuator circuit
consisted of OP AMP U1403-B.
Part of this signal is outputted to the test BNC connector (VAR 30 Hz) attached on the front
panel of MON via the OP AMP buffer U1404-A.
The detected variable 30Hz signal is supplied to the 60Hz active low pass filter U801-B via
the 1-of-8 analog switch (MUX2) U800 and buffer circuit U801-A. Here, the unnecessary
signal elements more than 60Hz are removed.
Finally, the variable 30Hz signals pass through the 1-of-16 analog switch U803 and are
converted into the digital data after being sampled from the A/D converter U703. At this
time, the sampling frequency is 1/ 960 second. In other words, the data is sampled at the
rate of 32 for one cycle of 30Hz signal (32 samples/cycle 960 samples/sec).
The amount of data sampled for one time of signal processing is the amount for two cycles
of 30Hz signal processing, which are 64 samples. From these, the 32 data in the back are
used in processing the Fast Fourier Transform (FFT). Since it is possible to have incorrect
data for a certain period of time until the signal is stabilized after the path corresponding to
the respective analog switches of MUX1, MUX2 and MUX3 is selected, the first 32 data
are not used.
Since the sampling frequency is 960Hz and the used data are 32, the magnitude shown in a
complex number with the respective frequency elements in the interval of 30Hz from the
range of 0 Hz (DC) ~ 480 Hz is obtained from the FFT result. By taking the real number
part and imaginary number part of 30Hz elements, the phase of variable 30Hz signal can be
calculated according to the equation below.
Im( A30Hz )
VAR arctan
Re( A30Hz )
Since the phase of reference 30Hz is calculated from the section 3.6.8, the azimuth can be
calculated according to the equation below if the phase of variable 30Hz can be known.
VAR REF
A30Hz f max
Also since the variable 30Hz signal is fixed with the frequency 30Hz at the time of being
modulated, the FM index () from the magnitude of 30Hz elements can be calculated.
f max f max
K A30Hz
f mod 30
Figure 3-44 shows the steps of measuring the amplitude modulation degree of 9960 Hz FM
sub-carrier wave signal.
Same as the processing steps of other analog signals, the demodulated VOR composite
signal in the RF signal process circuit and the test signal generated from the test signal
generator (TSG) are applied to U1201. U1201 is controlled by the MON software and one
of these two is selected and passed.
The VOR composite signal that has passed U1201 includes the reference 30Hz signal and
1020Hz IDENT in addition to the 9960 Hz FM sub-carrier wave. Since these unnecessary
signal elements need to be eliminated to obtain the 9960 Hz AM modulation degree, the
high pass filter (HPF) is used. U1601, as an active HPF, allows only the 9960 Hz sub-
carrier wave elements passing through.
The signal that has passed through the U1603 HPF is converted to the DC signal from the
precise full-wave AM demodulation circuit consisted of D1600 and D1601.
This DC signal is supplied to the 60Hz active low pass filter (LPF) U801 after passing
through the analog switch U800 (MUX2). Since the unnecessary AC elements from the
signals converted into DC can be left over, U801 eliminates these and allows only the DC
elements passing through.
The pure DC elements obtained through the above described process again pass through
the analog switch U803 (MUX3), are sampled from the A/D converter U703, and are
converted into the digital data.
The amplitude modulation degree of the 9960 Hz FM sub-carrier wave signal can be
calculated according to the equation below.
A9960Hz VDC
m9960Hz
A0 Hz A0 Hz
Here, VDC as the elements corresponding to the 9960 Hz sub-carrier wave has the
magnitude of DC elements obtained above and A0Hz as the elements corresponding to the
primary carrier wave signal has the magnitude of DC elements obtained from the
processing steps of reference 30Hz signal.
Figure 3-45 Measuring the Amplitude Modulation Degree of 1020 Hz IDENT Signal
Figure 3-45 shows the steps of measuring the amplitude modulation degree of IDENT
signal.
As shown in the figure, the VOR composite signal demodulated from the RF signal
processing circuit is inputted to the analog switch U1201 for other analog signal processing
and at the same time is supplied to the OP AMP buffer U1200-A for the IDENT signal
processing.
The composite signal that has passed through the OP AMP buffer U1200-A is applied to the
1020 Hz band pass filter (BPF) U1500. U1500, as a switched capacitor filter, operates after
receiving the clock signal of 61440 Hz from U400. While the IDENT signal of the
frequency 1020 Hz passes through this BPF, the rest of unnecessary signals are filtered here.
The IDENT signal that has passed BPF is converted into the DC signal from the precise
full-wave AM demodulation circuit consisted of the diodes D1500 and D1501 and the OP
AMP U1502, via the OP AMP buffer U1501-A.
The signals converted into DC can include the signals of high frequency elements in
addition to the Morse code IDENT signal that is keyed at the rate of 7 words per
minute ( 350 baud/min, 58.1 baud/sec). Since these elements can interfere in processing
the IDENT signal, they are filtered by using the LPF with the cut-off frequency of about
10 Hz. The OP AMP U1503 consists the active low pass filter (LPF) circuit that is used
here.
Same to the processing steps of other signal elements, the signals that have passed 10 Hz
LPF are inputted to the A/D converter U703 via the analog switch U803 (MUX3), 60 Hz
LPF U801, and again analog switch U803 (MUX3).
The A/D converter U703 samples the inputted signal and converts into the digital data, and
this data is processed by the MON software to get the amplitude modulation degree of
IDENT signal.
In addition to the modulation degree of IDENT signal, the code carried with the IDENT
signal in a form of Morse code needs to be decoded to check whether the code and
repetition cycle is transmitted according to the rules.
Figure 3-46 shows the steps of decoding the codes of IDENT signal.
Figure 3-47 shows the timing of Morse code IDENT signal.
The IDENT signal that has passed the 10 Hz LPF U1503 is inputted to the A/D converter
for measuring the amplitude modulation degree and at the same time converted in to the
TTL level from the level conversion circuit consisted of the OP comparator U1503 and
transistor Q1500 for the code decoding. Together with these, the IDENT LED on the front
panel is operated by using Q1501 to indicate the IDENT visually.
The IDENT signal converted into the TTL level is sent to the microprocessor U300 via the
3-state data buffer IC U605. The microprocessor U300 reads the TTL level IDENT signal
status that is entered to U605 every 1.04ms by using the timer interrupt of 960 Hz cycle.
MON software detects the time that this level is changed from the state of L to H and
measures the time between these two. By doing so, calculate the merit (DOT) and demerit
(DASH) and the interval and order mix of PAUSE, and then decode the Morse code from
that.
The signals dividing each output frequency into 40 from the SYN of CMA and SMA are all
transmitted to MON and inputted to the 8-input multiplexer IC U1001. U1001 is controlled
by the MON software and selects the signal to be measured.
The selected signal is applied to the input TIN1 of the microprocessor U300 programmable
timer 1. The output TOUT1 of timer 1 is cascaded to the input TIN2 of timer 2 and
constructs a 24-bit programmable counter as a whole.
MON software opens the gate of this counter for exactly 400ms and counts the signals
inputted. Hence, the actual frequency is obtained by multiplying 2.5 (= 1 sec / 400 ms) to
the number read by the counter.
MON software generates an alarm when the measured frequency goes beyond the
allowable setting range.
Figure 3-49 Timing Diagram for Monitoring the Status of Transmission Antenna
MARU 220 DVOR checks the abnormality by monitoring the status of the carrier wave
antenna and each sideband antenna in operation and can indicate which antenna is having a
trouble when an abnormality exists among the sideband antennas.
PDC compares the magnitude of the reflective wave voltage generated from the carrier
wave path with that of the reference and sends the result to MON. This status signal is
inputted to the 3-state data buffer U604 and is read by the microprocessor U300.
MON software, if this signal level is maintained with L for a certain period of time,
judges that the carrier wave antenna is having a trouble and generates the antenna alarm.
PDC compares the magnitude of the reflective wave voltage generated from the sideband
path with the fixed reference voltage and sends the result to MON. This status signal is
inputted to the 3-state data buffer U604 and is read by the microprocessor U300.
MON software, if this signal level is maintained with L for a certain period of time,
judges that the sideband antenna is having a trouble and generates the antenna alarm.
In order to detect the antenna number that is having a trouble among the 48 sideband
antennas, it is provided with the 30Hz trigger signal synchronized to the antenna rotation
cycle from MSG via CSU and the 2880Hz clock signal.
More or less, it issues an interrupt to the microprocessor U300 whenever the antenna
switching occurs by using the 2880Hz clock signal. Also, it issues another interrupt to the
microprocessor U300 at the rotation cycle start point of the sideband antenna by using the
30Hz trigger signal.
MON software defines and uses the variables of indicating the sideband antenna number
that is internally selected. Whenever an interrupt is issued by the trigger signal, this
variable is initialized and this variables value is increased whenever the interrupt by the
2880 Hz clock occurs. By doing so, MON software can recognize the antenna number
selected at the point whenever the sideband antenna is switched.
MON software, whenever a periodic interrupt occurs, checks the level of sideband antenna
status signal at that point from PDC and detects the sideband antenna number with a
trouble.
The output level of sideband wave is detected from PDC and sent to MON.
The carrier wave output detection signal sent to MON passes through the analog switch
U803 (MUX3) and is converted into the digital data from the A/D converter U703.
Since the carrier wave output signal, sampled to detect the output level from PDC, is an
amplitude-modulated signal, the magnitude of the signal sent to MON gets changed
periodically. At least one cycle of modulated signal data is taken and averaged to indicate
the average output power.
MON software in this signal takes 64 data samples at a time and calculates the average of
the last 32 samples. A software type of lookup table is used to get the output power shown
in watts from this calculated value. Since this lookup table is saved to the non-volatile
memory attached on the system backplane, it can be shared by MSG and MON.
MARU 220 DVOR uses two independent monitors. The data exchange between two
monitors is essential to determine the executive action such as switching to the standby TX
or interrupting the TX by detecting the abnormality of a monitor.
The data exchanged at this time are the status values that show whether or not the
monitoring result of each monitor is right. This data are exchanged from each other through
U602 and U603.
The current system status that has monitored each monitor is outputted to the 8-bit data
latch IC U602. The output of U602 is connected to the 3-state data buffer U603 of the other
party. U602 and U603 is connected to the data bus of the microprocessor U300 and
controlled by the MON software.
The lowest bit (b0) among the 8-bit data exchanged between two monitors indicates
whether the signal radiated is right or not and if this bit is L, it means that the radiated
signal is not right and an alarm has occurred.
Apart from the voltage and current measured internally within PSS by LCU, the respective
voltages supplied to the backplane of CMS and MAS are monitored by MON.
Since the maximum input voltage of the A/D converter U703 that includes MON is 5V, the
input voltage should be divided to be less than 5V to measure each power voltage. Each
voltage on two backplanes are divided into the voltages of 3~4V through the resistors
R905~R934 and they are applied to the A/D converter U703 via the OP AMP buffer U903
and analog switch U803.
If the respective voltages measured in this way goes beyond a setting range, the
corresponding alarm is generated.
The foremost one in the analog signal processing system is the signal selection switch
U1201 (MUX1). The signals applied to U1201 are the demodulated VOR composite signal
in the RF signal processing circuit and the test signal generated from the test signal
generator (TSG).
U1201 is controlled by the MON software and allows passing through by selecting one of
two signals. The signal processing steps from then on are identical.
TSG generates the test signals by synthesizing in a digital method according to the equation.
Hence, the respective parameters of these test signals are fixed in advance and precise
signals are obtained without an error.
TSG can output one among the 16 test signals numbered from 0 to 16 as shown in the
following table. In the normal times, only the one with 0 is used and it is used to check
the monitor in the preventive maintenance process. Operator judges which test signal TSG
is to output and operator controls it through LCU.
MON software periodically analyzes the test signals generated from TSG and calculates
each signal parameter and checks whether or not the error is within the allowable range.
When the analysis result of this test signal exceeds the allowable range, it judges that the
monitor itself is having an trouble.
9960Hz
30Hz AM 30Hz FM
No. AM Azimuth Remarks
Depth Mod-Index
Depth
The changeover function from the primary transmitter (TX) to the standby transmitter is
controlled by MON and the interface circuits related to it are all included in CSU. The
outputs of two transmitters are either sent to the antenna by the coaxial relay and RF relay
included in PDC or connected to the dummy load.
Hence, the steps of changing over to the transmitter are to reverse the routine by controlling
the relay. However, it is not advisable for several reasons to change over the relay contact
point while the high-power RF signal is applied. Therefore, it is advisable to cut-off the RF
output temporarily before changing over the relay contact point. However since MSG
controls the RF output, MON cant directly cut-off the transmission output. Hence, this
process is made in the way of signaling indirectly to MSG by using the hard flag included
in CSU.
There are two cases that the transmitter is changed over. One is that it is automatically
changed over by detecting a serious problem when the monitor is in the active state or user
manually changes over regardless of the monitor status. According to the cases, the process
that the transmitter is changed over is somewhat different.
In this case, the path connected to the antenna is changed while maintaining the ON/OFF
state of the transmitter.
1) Judge which one is active or standby first by reading the contact point status of the PDC
coaxial relay from CSU.
2) MON sets the hardware flag within CSU.
3) MSG reads this hardware flag periodically and cuts-off the transmitter output
temporarily if it is set.
4) MON monitors the transmission output and MSG waits until the transmission output is
temporarily cut-off.
5) If the cut-off of the transmission output is confirmed, MON sends the relay changeover
signal to CSU.
6) MON checks whether or not the relay is changed over by reading the contact point status
from CSU.
7) MON clears the hardware flag in CSU to recover the transmission output again.
8) Each MSG waits for the hardware flag in CSU to get cleared and restores that to the
original transmission output.
In this case, the path connected to the antenna is changed over while the transmitter active
up until now becomes off and the transmitter in the standby state becomes on.
1) Judge which one is active or standby first by reading the contact point status of the PDC
coaxial relay from CSU.
2) MON sets the hardware flag within CSU.
3) MSG reads this hardware flag periodically and cuts-off the transmitter output
temporarily if it is set.
4) MON monitors the transmission output and MSG waits until the transmission output is
temporarily cut-off.
5) If the cut-off of the transmission output is confirmed, MON sends the relay changeover
signal to CSU.
6) MON checks whether or not the relay is changed over by reading the contact point status
from CSU.
7) When the relay changeover is confirmed, the standby transmitter waiting up until now
becomes on.
8) Reversely, the primary transmitter that has been active becomes off.
9) MON clears the hardware flag in CSU to recover the transmission output again.
10)Each MSG waits for the hardware flag in CSU to get cleared and restores that to the
original transmission output.
If a serious problem occurs even after the transmitter is changed over, the transmitter
currently in an active state becomes off. In other words, two transmitters become off and
the system gets shutdown.
3.7. MSG
3.7.1. Appearance of MSG
LEDs
Switches
Name Description
RESET The switch that resets the MSG CPU
MSG generates the respective modulation signal and antenna switching control signal and
supplies them to ASU. Also, it controls the system variables such as transmission output
and modulation degree.
Generate the composite signal that consists of the carrier wave modulation signal that
is the 30Hz reference phase signal, IDENT and voice. This signal is supplied to CMA.
The function of keying the fixed IDENT code into the Morse code includes of
generating the IDENT signal. The voice signal is included into the composite signal
by receiving an external input.
Generate the SIN blending signal and COS blending signal, which are the sideband
modulation signals. These signals are supplied to each SMA.
Control the amplitudes of carrier wave and sideband modulation signals and set the
respective transmission outputs.
Generate the control signal for switching the antenna. This signal is supplied to ASU
via CSU.
Automatically control the phase of RF signal to be transmitted. By measuring the
phase error between carrier wave and two sideband signals, it adjusts the voltage
applied to the phase regulator of SMA to correct it.
Set the oscillating frequency of SYN in CMA and two SMAs, which is the
transmission frequency of the system.
Measure each transmission output and monitor the internal temperature of MSG.
U1504-1505
LSB/USB 9960 Phase
Com BNC TP COMP
U1400-1403
VOICE
DAC Amp
Voice AM
Amp
DAC Amp
COMP
U906 U1002
Power DET. ADC Ref.V
Amp U904 U1000 U1003
U1404 U1405
Data
Ant. Timing DAC 30Hz DAC 30Hz AM
Amp Amp
U800 U900
C-DATA
U801 U901
EPROM
ID Sound
MAS Cotrols
MPU U701 DAC
Amp
1020Hz DAC
Amp
MUX ID
Amp
Hot Plug-In Controls
EPROM
USB COS
BNC TP
U600 DAC
Amp
COS
U1200
EXT. EEPROM S/W EEPROM
U1201
U1802 U603
USB SIN
BNC TP
Ref.V DAC
Amp
U1106 U1300
Data
SIN
Reset Logic
U1301
U301
11.796480MHz [X701]
Data
Hot Swap Controls
7.864320MHz [X700]
Data
-15V / 200mA Max PWR TxD RxD HALT Ref.V DAC LSB Phase
Amp
U300 is the microprocessor for the main control of LCU. U300 is based on the M68000
core and the 1152-byte dual port RAM, programmable timer, serial communication
controller (SCC), and 24-bit general GPIO are integrated within the chip. The data and
address buses of U300 are connected to the peripheral devices through the 3-state buffer
U500-U504.
U301, as the microprocessor monitor circuit IC, includes the reset signal generation circuit,
power monitor circuit and watchdog timer circuit. U301 supplies a reset signal to the
microprocessor U300 and at the same time, it monitors whether U300 operates normally.
The cases that U301 outputs a reset signal follow as below.
The crystal oscillating circuit X1001 supplies a clock of 29.4912 MHz to U300.
When the reset signal of U301 is outputted, the FAULT LED lamp on the front panel of
LCU is lighted on.
Since the /RESET output signal of U301 is also connected to the /OE pin of the bus
switches U1903 ~ U1907 via Q300, the I/O signal line of LCU is separated from the
backplane during the reset period.
MSG uses the following storage devices different from each other. All the rest of storage
devices except for the serial EEPROM are positioned within the memory space of the
microprocessor U300.
EPROM U600 and U601: Store the program code and data
SRAM U601: Store the temporary data used during the program execution
EEPROM U603: Store the non-volatile parameters
Additionally, MSG uses the public EEPROM attached to the backplane.
The EEPROM U603 inside of MSG and the public EEPROM attached to the backplane are
multiplexed by the analog switch U1802. The analog switch U1802 is controlled by the
microprocessor U300 so that the MSG software can access the data of two EEPROMs.
The 3 serial communication ports included in U300 are used for the following purposes.
SCC1: The RS-232C serial communication for exchanging data with LCU
SCC2: The RS-232C serial communication for software debugging and factory test
SCC3: The 3-lined serial data interface (SPI) for controlling the A/D converter U1404
U400 is a programmable logic device (PLD). It includes the logic circuits such as the
address decoder and GPIO port.
The address decoder inside of ELPD U400 decodes the addresses for each memory and I/O
device and generates the Chip Selection Signals, from the address bus and control bus
signals of the microprocessor U300.
The GPIO port of U400 consists of the latch circuit for the output port and the digital
switch circuit for the input port.
The modulation signal for carrier wave is the composite signal that the 30Hz reference
phase signal, IDENT and voice are overlapped on a fixed magnitude of DC.
The carrier wave level in the modulation process is determined according to the
magnitude of DC elements included here. The amplitude modulation degree of each
element is individually controlled by adjusting the magnitude of the corresponding
elements included within the composite signal.
The 30Hz reference phase signal, as the reference signal of measuring the azimuth, is
synchronized to the control signal for switching the antenna.
IDENT is obtained by keying the 1020Hz sine wave into the preset Morse code.
Voice, as the audio signal of 300 ~ 3000 Hz, is included to the composite modulation
signal when having an external input.
The 30Hz reference phase signal and 1020Hz IDENT should have an accurate sine wave
and at the same time, the frequency should be highly stabilized. Also, the 30Hz reference
phase signal should be phase-synchronized to the antenna switching signal and the phase
offset should be precisely controlled.
The 30Hz and 1020Hz signals are digitally synthesized by using the Direct Digital
Synthesis (DDS) technology for these. DDS is the technology of generating the sine wave
of having accurate frequencies by reading the numeric data of the wave saved within the
memory and by sending them to the D/A converter. The phase of generated signals can be
precisely controlled digitally by controlling the timing of taking out the wave data from the
memory by using the DDS technology.
The numeric data of 30Hz and 1020Hz signal waves are saved in the EPROM U701. U701
is separated by the odd-numbered addresses and even-numbered addresses and the 30Hz
signal wave data are saved to the even-numbered addresses and the 1020Hz signal wave
data to the odd-numbered addresses.
The 30Hz signal wave data read from U701 are sent to the D/A converter U800 and the
1020Hz signal wave data to the D/A converter U803 and they are converted into the analog
signals.
The address signals of EPROM U701 and the write signals of D/A converters U800 and
U803 are made by the EPLD U700. The trigger signal for the phase-synchronization
between 30Hz reference phase signal and antenna switching signal are made within U700
in the same way. In order to generate these signals, U700 receives the 7.864320 MHz clock
from the crystal oscillator X700 and uses it.
The phase control of 30Hz reference phase signal is made by supplying the phase offset
value from the microprocessor U300 to the EPLD U700. Since the phase offset data have
the 14-bit length, it can be adjusted by 0.1 in the range of 0 ~ 359.9 . Accordingly, the
30Hz reference phase signal is accurately delayed to the offset set by the synchronization
trigger signal and outputted.
The D/A converter U800 and U803 receive an accurate +10V power from the reference
voltage U1106 and use it as the reference voltage. Since U800 and U803 are the current-
output type of D/A converters, they are converted into the voltage output by using the
precise operation amplifiers U801 and U802.
The output of U801 or 30Hz reference phase signal is inputted to the reference voltage
input (VREF) pin of D/A converter U900 for the control of modulation degree. Since U900
is a multiplying D/A converter, the signal inputted to the VREF pin is amplitude-adjusted
by the inputted data value and appears on the output pin (IOUT1). The current output of
U900 is converted to a voltage by U901.
In the same way, the output of U802 or 1020Hz signal is inputted to the reference voltage
input (VREF) pin of D/A converter U903 for the control of modulation degree. Since U903
is a multiplying D/A converter, the signal inputted to the VREF pin is amplitude-adjusted
by the inputted data value and appears on the output pin (IOUT1). The current output of
U903 is converted into a voltage output by U902.
This signal is inputted to the analog switch U909 for keying the Morse code again. The
Morse code keying is either controlled by the MSG software in the microprocessor U300 or
mad by receiving the keying signal from the collocated DME. The signal keyed by the
MSG software and the keying signal are all inputted to the EPLD U700. One of two keying
signals is selected according the system setting within the internal logic circuit of U700 and
the selected signal controls the ON/OFF functions of the analog switch U909.
The voice signal is inputted through the microphone jack or line input on the front panel of
CSU and is provided to MSG via the voice signal processing circuit (VOP) within the CSP
unit. The voice signal supplied to MSG is inputted to the reference voltage input (VREF)
pin of the D/A converter U906 for the control of modulation degree. Since U906 is a
multiplying D/A converter, the signal inputted to VREF is amplitude-adjusted according to
the inputted data value and appears on the output (IOUT1) pin. The current output of U906
is converted into a voltage output by U904.
Each modulation signal made through the process described above becomes the composite
signal for the modulation of carrier wave, which is combined with the addition circuit
consisting of the operation amplifier U1000 together with the precise +10V reference
voltage (DC).
This signal is inputted again to the reference voltage input (VREF) pin of the D/A
converter U1002 for the amplitude control. Hence, the amplitude-adjusted composite signal
is outputted to the output (IOUT1) pin of U1002. The current output of U1002 is converted
into a voltage output by U1003.
The modulation signals for sideband are two 720Hz blending signals. The blending signal
is used to obtain the continuous rotation effect of sideband antenna and it can be divided
into the COS blending signal and SIN blending signal that are supplied to the odd-
numbered antenna and even-numbered antenna respectively. The basic blending signal
holds the rectified sine wave form as shown in the figure 3-52 and the COS blending signal
and SIN blending signal have a 90phase difference from each other.
The amplitude of blending signal determines the sideband output power and this fixes the
amplitude modulation degree of 9960Hz sub-carrier wave. Therefore, the sideband output
power can be adjusted by controlling the amplitude of blending signal and as the result the
amplitude modulation degree of 9960Hz sub-carrier wave can be adjusted.
The frequency of blending signal, same to the 30Hz reference phase signal, should be
highly stabilized and phase-synchronized to the control signal of switching the antenna.
In order to accomplish it, the blending signal uses the DDS technology in the same way as
the carrier wave modulation and is digitally synthesized.
The numeric data of blending signal wave is saved in EPROM U702. U702 is separated by
the odd-numbered and even-numbered addresses and the COS signal waveform data is in
the odd-numbered addresses and the SIN signal waveform data in the even-numbered
addresses. Since 4 types of blending waveform data are saved in U702 and one of them can
be selected and used.
The COS signal waveform data read from U702 is sent to the D/A converter U1100 and the
SIN signal waveform data to the D/A converter U1103 and they are converted into the
analog signals.
The address signal of EPROM U702 and the write signal of D/A converters U1100 and
U1103 are made by the EPLD U700 together with the carrier wave modulation signal.
However in order to generate the blending signal unlike the carrier wave modulation signal,
it receives the 11.796480 MHz clock from the crystal oscillator X701 and uses that.
The D/A converter U1100 and U1103 receive an accurate +10V power from the reference
voltage IC U1106 and use it as the reference voltage. Since U1100 and U1103 are the
current-output type of D/A converters, they are converted into the voltage output by using
the precise operation amplifiers U1101 and U1102.
The output of U1101 and U1103 or the COS blending signal and SIN blending signal are
divided into LSB and USB. Each blending signal is inputted respectively to the reference
voltage input (VREF) pine of D/A converter U1200 (USB COS), U1203 (LSB COS),
U1300 (USB SIN) and U1303 (LSB SIN). Since U1200, U1203, U1300 and U1303 are all
the multiplying D/A converter, the signal inputted to the VREF pin is amplitude-adjusted
by the inputted data value and appears on the output (IOUT1) pin. The current output is
converted into the voltage output range of 0 V ~ -10 V by U1201, U1202, U1301 and
U1302.
Figure 3-53 shows the timing of basic COS and SIN blending signals. The reason that the
blending signal waveform is reversed from the figure is because SMA requires the -
modulation signal.
The antenna switching signal is the signal to control the switching operation of ASU to
obtain the rotation effect of sideband antenna.
The antenna switching signal is supplied separately by the odd-numbered (COS) signal and
even-numbered (SIN) signal. Each switching signal consists of the LSB/USB toggling
signal 1-bit and selection signal 4-bits for selecting one of 12 antennas within one group
(refer to the paragraph 3.1.4.
The frequency and timing of antenna switching signal should be very accurate and should
be precisely phase-synchronized with the 30Hz reference phase signal and blending signal.
In order to accomplish these, the antenna switching signal is generated within the internal
logic circuit of EPLD U700 by receiving the 11.796480 MHz clock from the crystal
oscillator X701.
For the phase synchronization, the trigger signal with the pulse width of 127ns is accurately
generated at every 1/30 second within the EPLD U700. The sequential logic circuit for the
generation of antenna switching signal and blending signal is initialized at the rising point
of this trigger signal. Also, the sequential logic circuit for the generation of 30Hz reference
phase, after the time delay corresponding to the azimuth offset set from this point, is
initialized.
As shown in the figure, the phase of even-numbered (SIN) switching signal is delayed by
1/1440 second from that of odd-numbered (COS) switching signal.
U700, in addition to the signal supplied to ASU, generates two timing signals that are
supplied to MON for monitoring the status of sideband antennas, which are the 30Hz
trigger signal and 2880Hz clock signal that are synchronized to the antenna rotation cycle.
One of the antenna switching signals generated respectively from the MSG of TX1 and
TX2 is selected by the selection circuit in CSU and the level is converted and supplied to
ASU.
1/30 sec
variability
Reference 30Hz
0 ~ 359.9 Deg variability
1/720 sec
COS Blending
SIN Blending
1/1440 sec 1/720 sec
COS Toggle
1/60 sec
1/720 sec
SIN Toggle
127ns
VSWR 2880Hz
Figure 3-57 is the phasor diagram that shows the RF phase relationship of a carrier wave
and two sidebands.
CAR
LSB USB
2
1
In the Doppler VOR of using double sidebands (DSB), it is important to maintain the RF
phase relation of carrier wave and two sidebands so that 1 and 2 are always equal (that is
1 - 2 = 0).
It has only regarded the signal radiated in the air and the value of 1 - 2 may not be 0
since there would be a phase difference in the actual equipment by each path.
Therefore for the signal generated from CMA and SMA, CAR, USB and LSB need to be
adjusted so that it becomes 1 - 2 = k (a fixed offset value).
To accomplish it, MSG automatically adjusts the voltage applied to the Phase Shifter
included in LSB SMA and USB SMA. In reality, a fixed voltage is applied to USB SMA
and the difference (that is the voltage corresponding to the phase error) between 1 - 2 and
k value is applied to have the control.
Two sideband signals from LSB SMA and USB SMA are mixed with the carrier wave
signal and are converted respectively to the intermediate frequency signal of 10 kHz.
Hence, the phase of two 10 kHz intermediate frequency signals holds the values (1 and
2) corresponding to the difference between carrier wave and two sideband phase.
MSG inputs two 10 kHz signals supplied from LSB SMA and USB SMA to the Time
Interval Counter and calculates the value of 1 - 2.
Since the 10 kHz intermediate frequency signals supplied from two SMAs are the sine
wave type of analog signals, they are first inputted to the IN2- and IN3- pins of the voltage
comparator U1504 and converted into the TTL level of square wave.
The time interval counter, as a digital logic circuit, is implemented within the EPLD U400.
The measured results are read by the microprocessor U300.
MSG software periodically reads the values measured from the time interval counter,
converts them into the phase values, and calculates the phase error value which is the
difference in the preset RF phase offset. Calculate the voltage to be applied to the phase
regulator of LSB SMA and USB SMA from this value and automatically adjust the RF
phase by setting the value to the D/A converters U1702 and U1704.
In addition to the contents described above, MSG sets the oscillating frequency of SYN
which is the transmission frequency of the system, controls the ON/OFF of SMA and CMA,
and monitors the operation status by measuring the output power of carrier wave and
sideband and its internal temperature.
MSG, in order to set the transmission frequency of the system, transmits the frequency data
to the PLL circuit included within the SYN of CMA and SMA through the 3-line serial data
interface.
The 3-line serial data interface consists of three signals DATA, CLOCK and ENABLE and
all of them are controlled through the GPIO A of the microprocessor U300. DATA and
CLOCK are used publicly by CMA and two SMAs and are connected respectively to the
PA2 and PA3 pins of U300. ENABLE is used individually to all. CMA is connected to the
PA4 pin of U300, USB SMA to PA5, and LSB SMA to PA6.
U1404, as the A/D converter equipped with the SPI serial data interface, is controlled
through the SCC3 of the microprocessor U300. The precise reference voltage IC U1405
supplies a precise +5V reference voltage to U1404. U1404 has the 8-channel input and
each input is used in the following ways.
CH 1 (AIN1): Measure the forward directional (traveling wave) power of carrier wave
CH 2 (AIN2): Measure the reverse directional (reflective wave) power of carrier wave
CH 3 (AIN3): Measure the USB COS output power
CH 4 (AIN4): Measure the LSB COS output power
CH 5 (AIN5): Measure the USB SIN output power
CH 6 (AIN6): Measure the LSB SIN output power
CH 7 (AIN7): Not used
CH 8 (AIN8): Not used
Each measured signal is sampled and detected from PDC and sent to MSG and they are
supplied to the respective inputs of A/D converter via the buffer of having used the OP
AMP U1400, U1401, U1402 and 1403. The allowable voltage range of each input is 0 V ~
5 V.
When measuring the carrier wave power, the amplitude varies periodically since the signal
sampled from PDC is amplitude-modulated by the 30Hz sine wave. In order to indicate the
average output power, 24 data are taken and averaged to get the average power for the
cycle (1/30 second) of modulated signal.
To accomplish it, the trigger signal of indicating the start point of modulation signal and the
synchronized sampling clock signal are supplied to the GPIO port of the microprocessor
U300 from the EPLD U700. The microprocessor U300 issues an interrupt whenever a
pulse is inputted to the corresponding port and calculates the average of inputted carrier
wave power.
The digital temperature sensor U1801 included in the MSG board uses the 3-line serial data
interface and is connected to the GPIO A of the microprocessor U300. MSG software
periodically reads the temperature from U1801 and monitors the status.
3.8. CSU
3.8.1. Appearance of CSU
LEDs
Switches
Switch Description
TX1 ON Not used
TX1 OFF Not used
TX2 ON Not used
TX2 OFF Not used
Ports
Port Description
MIC The microphone input of voice to be included in the composite modulation
signal of carrier wave
TSG OUT Test output for the Test Signal Generator (TSG)
Although the power, transmitter and monitor are all duplicated to improve the system
availability, there are few parts that cant be or not practical to be redundantly constructed.
CSU, as one of these parts, includes the following functions.
Although the transmission part is redundant, the antenna itself cant be duplicated. Hence,
there should be a function of switching over to the standby transmitter while one
transmitter has the connection.
The function of changing over to the standby transmitter is determined first by the monitor.
Since the monitor itself is duplicated, there must be an interface function that two monitors
are linked together for the control of transmitter changeover.
For the transmitter redundancy, its selection and changeover control is necessary since not
only the respective RF output signals (CAR, LSB COS, LSB SIN, USB COS and USB
SIN) but also the antenna switching control signals supplied to ASU are duplicated.
The changeover of each RF output signal is made by the coaxial relay and RF relay that are
included in PDC. The changeover of the antenna switching control signals supplied to ASU
is made by the digital multiplexing (MUX) circuit included in CSU. CSU also includes the
circuit for monitoring and driving the relays included in PDC.
For the self-diagnosis and integrity checking of a monitor, the precise test signal that has
accurately defined the parameter values of each modulation signal is necessary. The test
signal generator circuit for this purpose is included in CSU.
The signal generated from the test signal generator are not only distributed to both monitors,
but also supplied to the outside through the test BNC connector (T/P) attached on the front
panel.
As an option, a voice signal can be included in the composite modulation signal of carrier
wave. The voice signal is either directly connected to the microphone jack attached on the
front panel of CSU or inputted through the line input terminal on the upper side of the
equipment cabinet.
Both cases are distributed to both of TX1 and TX2 MSGs while passing through the signal
processing steps such as amplification, filtering and compression. CSU includes the analog
signal processing circuit necessary for these.
Generally, VOR is collocated and operated together with the DME or TACAN equipment.
The collocated VOR/DME or VOR/TAC uses the same IDENT and transmits the IDENT
consisting of the Morse code 4 times every 30 seconds according to the rules of ICAO
Annex 10. Of these, the transmission is made 3 times by VOR and 1 time by DME or
TACAN.
Voice Input
AERIAL MON1
AERIAL MON2
Changeover Status
Antenna Timing MSG1 RF Power Status
Antenna Timing MSG2 PLD
U400
RS485 Driver
DCLK U401
RS485 Driver
U403
The digital logic circuits for supporting the redundancy of transmitter and monitor are all
implemented in the EPLD U400.
Of these two duplicated transmitters, the monitor determines which side is on the aerial
state by connecting the antenna or which side is on the standby state by connecting to the
dummy load. Monitor decides the transmitter to be connected to the antenna according to a
users command or by judging from the monitoring result of transmission signal and
transmits a short pulse type of control signal (TX1_AERIAL or TX2_AERIAL) to CSU for
the corresponding transmitter selection.
Since the monitor itself is duplicated, this control signal is supplied from both of the
monitors. These signals are all inputted to EPLD U400 and they select the transmitter
chosen first in the priority selection circuit to be connected to the antenna. The selection
result is not only supplied to the actual transmitter changeover circuit, but also sent to both
MONs and both MSGs for confirming the selection result.
According to the transmitter selection result, the RF relay drive circuit and antenna
switching signal selection circuit inside of EPLD U400 are controlled.
The RF relay drive circuit consists of the Mono-stable Multi-vibrator U500 and high-
voltage Source Driver U501. The latch-type of RF signal changeover relay included in
PDC requires a +28V pulse. U500 generates a pulse of about 100ms in length at the drop
point of selection control signal from EPLD. U501 converts this pulse signal to the voltage
+28V necessary to operate the relay and supply it to PDC.
The antenna switching signal selection circuit is implemented as a logic circuit inside of
EPLD U400. Each 10-bit antenna switching signal supplied from both MSGs is inputted to
the digital switch (MUX) circuit inside of U400. According to the transmitter selection
result described above, this switch selects the antenna switching signal supplied from the
corresponding transmitter and makes the output. The selected signal is converted to the
TTL compatible level or differential signal in the RS-485/RS-422 line drive IC U401, U402
and U403 and sent to ASU.
Test Signal Generator, same to MSG, uses the DDS technology and generates the precise
test signal accurately defined for the signal parameter of each element.
The DDS control circuit for the generation of test signals is implemented within EPLD
U600. U600 operates by receiving a clock of 7.86432 MHz from the crystal oscillator
X600.
The waveform data of test signals is saved in EPROM U601. U601 can save up to 16
different test signal waveforms. Of these one test signal is selected according to the control
signal from LCU and supplied to both monitors.
The waveform data saved to U601 are sequentially sent to the D/A converter and converted
into the analog signals. Since U601 is a current output type of D/A converter is converted
into the voltage signal from the conversion circuit consisted of OP AMP U604 and
outputted via the OP AMP buffer U605.
U603, as a precise voltage generator IC, supplies the +5V precision voltage as the reference
voltage of U602.
Since the test signal generated from the DDS circuit includes the high-frequency
quantization noises, they can be removed by passing through the analog filter U700. U700,
as a programmable Switched Capacitor Filter (SCF), consists of the 4th Chebyshev low pass
filter with the cut-off frequency of 20 kHz. The clock signal necessary for U700 is supplied
with 98.034 kHz in EPLD U601.
The signals that have passed through the filter U700 are supplied respectively to the test
BNC connectors attached on the front panel of both monitors via the OP AMP buffer U701
and U702.
LINE/MIC Selection
The voice signal is inputted to the voice processing circuit of CSU via the microphone jack
attached on the front panel or the line input terminal on the upper side of the cabinet.
Since the line input is a 600 balanced differential signal, it is converted into the common
unbalanced single-ended signal and inputted to the amplifier U1101-B analog switch
U1102 via the I/O separated transmitter TR1100 and line receiver U1100.
The microphone input signal is directly inputted to the analog switch U1102 via the
amplifier U1101-A.
U1102 outputs one of two inputs according to the control signal from LCU. The output
signal of U1102 is inputted to the IC U1103 for the voice compression and compressed by
15:1.
The compressed voice signal passes through the active band reject filter consisted of
U1200. The 1020Hz element that can cause interference to the Morse code IDENT by this
filter is rejected.
The voice signal that has passed through U1200 again passes through the 4-layer active
band pass filter consisted of U1201 and U1202. The noise signals beyond the 300~3000 Hz
voice signal band is rejected by this filter.
The voice signals that have passed the filter are distributed to the MSGs of both
transmitters via the OP AMP buffer U1203.
When operating by linking with VOR or DME (or TACAN), it can be divided by the
master unit that transmits the IDENT by generating the keying signal and the slave unit that
transmits the IDENT by receiving the keying signal.
When VOR operates as the master, DME operates as the slave. Oppositely when DME
operates as the master, VOR operates as the slave. MARU 220 can be set to operate as a
master or slave with the software.
Also, it can be divided into two according to the circuit configuration, when the master is
the sink current (Figure 3-63) or the source current (Figure3-64). MARU 220 supports
above 2 cases and the setting can be changed with the software.
Master Slave
R Vbias
KEY
to MSG
Figure 3-63 When the Master is the Sink Current and the Slave is the Source Current
Master Slave
to MSG
KEY
Vbias R
Figure 3-64 When the Master is the Source Current and the Slave is the Sink Current
First, IDENT generation occurs from MSG. At this time, the keying signals of IDENT not
only key the IDENT of VOR within MSG, but also supply it to DME via CSU.
CSU receives the keying signals from the MSGs of two transmitters TX1 and TX2 and
input them to the analog switch U300. U300 selects the keying signals from the
corresponding transmitter and switches the transistor Q304, according to the selection
signals.
Q304 operates the Photo-coupler PT300-B and generates the signal that is separated by
power and ground. This signal switches the Darlington-connected transistors Q300 and
Q301 and operates the keying circuit of DME, by using the power on the side of DME.
The VOR status signals supplied to DME are also inputted and selected as the analog
switch U300 in both MSGs and supplied to the transistors Q302 and Q303 after being
separated into power and ground through the transistor Q305 and Photo-coupler PT300-A.
The keying signals from DME are converted into the TTL control signals from CSU and
distributed to the MSGs of both transmitters.
CSU operates the Photo-coupler PT-301 by receiving the keying signals from DME.
Both are supported through the selection relay REY300. REY300 operates the Photo-
coupler PT301-A directly when the keying signal is a current source and selects to operate
the PT301-A by using the +15V power when the current is a sink. The control of the relay
REY300 is driven through the logic reversal circuit U301-E and transistor Q308 according
to the selection signal of LCU.
The signal separated by power and ground through PT-301 is supplied to both MSGs after
passing through the switching transistor Q306, logic reversal circuit U301-A and U301-B.
The status signal of DME is also supplied to both MSGs via Q307 and logic reversal circuit
U301-C and U301-D after passing through the current sink/source selection relay REY301
and Photo-coupler PT301-B.
3.9. CSP
3.9.1. Appearance of CSP
Keypad
LED Lamp
CSP is a user interface device attached on the upper side of the equipment cabinet. CSP is
the I/O device connected to the primary microprocessor of LCU.
CSP consists of 1 240x64 mono-graphic LCD, 12 LED lamps, 7 manipulation keys, and 1
warning sound generation speaker. The connection between CMS backplane and CSP is
made through the 25P DB25 connector attached on the fixture inside of the equipment
cabinet.
Almost all the system functions, such as the status indication and parameter setting changes
of the system, can be controlled by using CSP without needing separate LMMS and
RMMS.
/CSP_RD
Graphic LCD
+5V Data
/CS_Switch
CS_LED1
CS_LED2
Latch Sink Driver LED LED Data 25pin
LED LED /CS_LCD
LED LED D-Sub
LCD_C/D
CS_LED1
Latch /LCD_RST
Sink Driver LED LED CS_LED2
LED LED /CSP_WR
LED LED
/CSP_RD
LED Control Part
LCD Operation
The graphic LCD is directly connected to the lower 8-bits of the microprocessor U300 data
bus of LCU.
For the LCD bias in addition to the +5V power supplied to CSP, a negative DC power is
needed. This power is supplied from the DC/DC converter U404. U404 generates the -10 V
DC power and this power is divided through the variable resistor VR300 for the brightness
adjustment and supplied to LCD.
The graphic LCD used to CSP uses the Cold Cathode Florescent Lamp (CCFL) as the back
light. In order to operate CCFL, a high-voltage of high frequency AC power is needed. This
power is supplied from the DC/AC inverter U301. U301 generates the 300 Vrms and
30 kHz AC power needed for CCFL from the +5V DC power.
Notice
Since there is a risk of an electric shock, please be careful not to touch the output poles of the
inverter when power is applied.
The 7 key inputs are sent to LCU through the buffer U300. Since each key line has the
pull-up resistors of R300 ~ R306, it maintains the high status when having no input and
outputs the low signal when having a key input. The prevention of key chattering is
implemented by software.
LED Control
LED is controlled by LCU, the High or Low is outputted on the latches U402 and U403,
and this signal is inputted to the sink drivers U400 and U401 to have the On/Off control of
LED.
3.10. AC / DC Converter
3.10.1. Appearance of AC/DC Converter
LED Lamp
Adjust Point
Name Description
V-ADJ No output voltage adjustment
LOAD SHARE No load balance adjustment
Switch
Name Description
INPUT Input power switch
AC/DC, as a Switch Mode Power Supply (SMPS), converts the inputted commercial AC
power into DC 28V.
AC/DC is constructed with a highly-efficient high-frequency conversion method and has
the hot plug-in structure that allows attaching/detaching it on the front side of the cabinet.
Since a digital ammeter is attached on the front side of the unit, the current load can be
easily checked.
Notice
Since there is a risk of an electric shock, please be careful not to touch the output poles of
AC/DC when power is applied.
3.10.3. Operations
The AC power of +220V is supplied for the input of AC/DC. The allowable variation of
input voltage is in the range of AC 187 V AC 253 V and the allowable variation of
input frequency is in the range of 47 Hz ~ 63 Hz. The maximum output current of DC 28V
is 78A per unit.
The surge protection circuit of using Varister is included in the input part of AC/DC. This
circuit, when the surge current is flowed into the power input line due to the lightning
strikes, prevents the system from a breakdown by absorbing them.
The input filter in the back of the surge protection circuit rejects the noise elements
included in the input power. The power that has passed through the input filter soon goes
through the inrush current limiting circuit. The inrush current limiting circuit restricts the
excessive current at the time of applying power to a certain extent. This prevents the
operation of a circuit breaker in the power transmission system due to the inrush current at
the time of applying power.
The AC power that has passed through the protection circuit and filter is rectified by the
full-wave rectification circuit of using a bridge diode. Then, the AC elements are rejected
by a smoothing capacitor and it is converted into a complete DC power.
Right behind the rectification circuit, there is a Power Factor Correction (PFC) circuit. This
circuit, by controlling the power factor nearing to 1, leaves the resistor elements only in
the transmission side. Through these, the occurrence of harmonic noise is reduced and the
efficiency of power use is improved.
The DC voltage that has passed through the PFC control circuit is applied to the Pulse
Width Modulation (PWM) circuit. The PWM circuit consists of the switching MOSFET,
transformer and feedback circuit.
PWM circuit samples the output voltage, compares it with the reference voltage, and varies
the pulse width applied to the switching MOSFET in comparison to the voltage error. If the
output voltage is lower than the reference voltage, the pulse width is increased and if the
output voltage is higher than the reference voltage, the pulse width is decreased.
The transformer converts the pulse power switched by the switching MOSFET to a low AC
voltage. The output of transformer is inputted again to the rectifier of using a high-speed
diode and converted into DC.
Since the switching noise and ripple elements are included much in the output of the 2 nd
rectifier, they are removed through the output filter.
The output voltage and the detection circuit for measuring the current are included in the
output area of AC/DC.
The detected voltage is sent to the PWM control circuit through the feedback circuit. If an
excessive voltage or current is detected, the PWM control circuit breaks an alarm and cuts
off the output to protect the circuit. Since the PWM control circuit has the built-in
temperature sensing circuit, it is also protected from overheating.
3.11. DC / DC Converter
3.11.1. Appearance of DC/DC Converter
LED Lamp
Adjust Point
Name Description
5V-ADJ No adjustment for +5V output voltage
Switch
Name Description
INPUT Input power switch
BATTERY Switch for connecting/breaking the backup battery
DC/DC converts the DC +28V power supplied by AC/DC into five other voltages (+5V,
+7V, +15V, -15V and +28V) needed for the system.
DC/DC is connected to the backup battery. When the DC 28V power is not supplied from
AC/DC, the power is supplied from this battery. Also when the backup battery is
discharged, it charges the backup battery by using the DC 28V power supplied from
AC/DC.
Same as AC/DC, DC/DC is basically consisted of the switch mode power supply (SMPS)
circuit. Also, it has the hot-swap structure that allows attaching/detaching a part easily from
the front side.
3.11.3. Operations
The following figure shows the overall block diagram of a DC/DC converter.
An input line filter is included within the input part of DC/DC. This filter removes the
In addition to the +28V primary power, DC/DC outputs the DC voltage of +5V, +7V, +15V,
-15V, and -24V necessary for the system. The circuit block that generates each voltage is
identical in the operating principle to the output voltage except for the difference in their
polarity. Therefore, the explanations below are made while basing on one circuit block.
The DC voltage that has passed through the input filter is applied to the Pulse Width
Modulation (PWM) circuit. The PWM circuit consists of the switching MOSFET,
transformer and feedback circuit.
PWM circuit samples the output voltage, compares it with the reference voltage, and varies
the pulse width applied to the switching MOSFET in comparison to the voltage error. If the
output voltage is lower than the reference voltage, the pulse width is increased and if the
output voltage is higher than the reference voltage, the pulse width is decreased.
The transformer converts the pulse power switched by the switching MOSFET to a low AC
voltage. The output of transformer is inputted again to the rectifier of using a high-speed
diode and converted into DC.
Since the switching noise and ripple elements are included much in the output of the 2 nd
rectifier, they are removed through the output filter.
The output voltage and the detection circuit for measuring the current are included in the
output area of DC/DC.
The detected voltage is sent to the PWM control circuit through the feedback circuit. If an
excessive voltage or current is detected, the PWM control circuit breaks an alarm and cuts
off the output to protect the circuit.
3.12. RCMU
3.12.1. Appearance of RCMU
Keypad
LED Lamp
RCMU is connected to the LCU of the equipment cabinet through a communication circuit.
RCMU sends major system information to the RMU that RCMU is connected.
UART
RS232 RS232 /1, RS232/2
UART Clock : Driver
ROM 14.7456MHz
MPU DATA MODEM
Socket Modem1
Buffer
Buffer
Main Clock :
29.4912MHz
SRAM RS232
UART RS232
SCC1 Driver
Buffer
RS232 RS485/1, RS485/2
UART Driver
Communication Part
Buffer
R-CSP Power [+5V]
Alarm Sound
R-CSP I/F
Remote Control Monitor Unit (RCMU) is a remote control and monitor unit. RCMU is
equipped with the graphic LCD, LED lamp and keypad that are identical to those attached
on the equipment cabinet. Since the menu configuration shown on the graphic LCD screen
is identical to that of CSP, the system monitoring and controlling function can be executed
at a distance.
RCMU, connected to the LCU of the system cabinet through a dialup or private line,
exchanges the data necessary for the system control and monitor.
Also, it relays the system status monitoring data received from LCU to RMU. RCMU and
RMU are connected from each other via the RS-422/485 compatible 4-line communication
circuit and as many as two RMUs can be connected to one RCMU.
Additionally, it has an expansion output port that indicates a brief status of the system. This
port can be used to interface with the centralized monitoring system.
RCMU is physically consisted of the main board, the R-CSP (RCMU CSP) board of having
LCD, KEY and LED, the RCMI (RCMU Interface) board for the interface to external
systems, and a small switching power supply (SMPS).
3.12.4. Processor
U300 is the primary control microprocessor of RCMU. U300 is based on the M68000 core
and the 1152-byte dual port RAM, programmable timer, serial communication controller
(SCC), and 24-bit general GPIO are integrated within the chip. The data and address buses
of U300 are connected to the peripheral devices through the 3-state buffer U500-U504.
The crystal oscillating circuit X300 supplies a clock of 29.4912 MHz to U300.
U301, as the microprocessor monitor circuit IC, includes the reset signal generation circuit,
power monitor circuit and watchdog timer. U301 supplies a reset signal to the
microprocessor U300 and at the same time, it monitors whether U300 operates normally.
The cases that U301 outputs a reset signal follow as below.
LCU uses the following storage devices different from each other. All the rest of storage
devices except for the serial EEPROM are positioned within the memory space of the
microprocessor U300.
EPROM U600 and U601: Store the program code and data
SRAM U602: Store the temporary data used during a program execution
EEPROM U605: Store the non-volatile parameters
When the microprocessor U300 is initialized after receiving the reset signal, U300 executes
the program code saved in the EPROM U600 and U601.
U400 is a programmable logic device (PLD). It includes the logic circuits such as the
address decoder and GPIO port. The address decoder inside of U400 decodes the addresses
for each memory and I/O device from the address bus and control bus signals of U300 and
generates the Chip Selection Signals. The GPIO port of U400 consists of the latch circuit
for the output port and the digital switch circuit for the input port.
Data
X300
Data DATA Address EPROM
DATA Data
Main Clock : BufferBuffer /CS_ROM
U600
U500,U501 /RD /CS_ROM
28.4912MHz /WR /RD
Address
EPLD /CS_FLASH
Microprocessor U400
U300
Address Address Address
Address
Buffer Data
Address
Buffer Buffer
Reset Logic U502,U503,U504 Address
U301 SRAM
/CS_SRAM U602
/RD
BUS Buffer /WR
Microprocessor
Peripheral Logic Memory Part
CLKO:29.4912MHz
EEPROM
SDA, SCL U605
Serial EEPROM
This port outputs the status value that shows the normality of the system. When this system
is normal, the PB8 of U300 outputs the High (5V).
RCMU, in addition to the 3 SCCs included in U300, has the synchronous communication
controllers (UART) U800, U801 and U802. Accordingly, a total of 9 serial communication
ports are available. The usage of each port shall be followed as below.
The UART0 and UART1 of U801 can either be connected to the default built-in socket
MODEM or use the direct RS-232C interface without using an internal MODEM by users
setting. In this case, set SW900 and SW901 to the RS232C position and remove the
internal socket MODEMs U1103 and U1104. In order to use the MODEMs again, set
SW900 and SW901 to the MODEM position and install the socket MODEMs U1103 and
U1104.
The asynchronous serial communication controllers U800, U801 and U802 operate by
receiving the output 14.7456 MHz from U400.
UART CLOCK:
14.7456MHz RS232 RS232/1 Communication
Driver
Data UART U900
TXD1 TXD Device
RS232 Driver /CS_MSG1,2
RXD1 U1001 RXD U800 RS232 RS232/2
Driver Communication
U901
RS232 (Not Used)
Microprocessor MSG1/2 Communication
UART CLOCK:
14.7456MHz RS232 Driver U902 MODEM1
Data
MODEM1
/CS_REM1,2 UART
Device
Buffer U801
RS232 Driver U903
MODEM2
EPROM MODEM2
UART CLOCK:
14.7456MHz
SRAM EPLD /CS_MSG1,2 REM1/2 Communication
U400 /CS_REM1,2
PLD CLOCK: /CS_REM3,4
29.4912MHz
UART CLOCK:
14.7456MHz RS485 RS485/1 Communication
Driver
Data UART U1002
Microprocessor Part Peripheral Logic Device
/CS_REM3,4
U802 RS485
RS485/2 Communication
Driver
U1003
REM3/4 Communication
The I/O process of serial communication data is made asynchronously by using an interrupt
method. When a data is received from the outside, the corresponding UART requests an
interrupt from the microprocessor U300. When an interrupt request is submitted, the
microprocessor U300 temporarily stops the code in execution, executes the interrupt
processing routine and reads the data from UART. The interrupt request signal of U800 is
inputted to the microprocessor through the PB8 and PB9 pins of U300, the interrupt request
signal of U801 through the PB10 and PB11 pins, and the interrupt request signal of U802
through the IRQ6 and IRQ7 pins.
The microprocessor U300 monitors the RXRDY and TXRDY pins of each UART through
U700 and U701. If one of these pins becomes the L state, the microprocessor U300 judges
that the corresponding UART is in the state possible to receive data and executes reading
and writing the data.
RCMU directly controls the LED lamps, graphic LCD and keypad on the front panel.
These devices are directly connected to the 8-bit lower data buses D0 - D7 of the CPU
through the 3-state data buffer U1101.
EPLD U400 decodes the address of U300 and generates the respective chip selection
signals /CSLCD, /CDSWITCH, /CSLED1 and /CSLED2 for the I/O devices included in
CSP.
The chip selection signals and other control signals of U300 are connected to the front
panel through the 3-state data buffer U1102.
RCMU generates the warning signals of about 1000 Hz by using the timer-2 of the
microprocessor U300. This signal is outputted to the TOUT2 pin of U300, amplified in the
audio amplification IC U1107, and played through the speaker on the front panel.
The magnitude of the alarm sounds and IDENT tone can be adjusted by turning the volume
VR1101.
The power supply unit (SMPS) supplies the power of +5V to RCMU.
3.13. RMU
3.13.1. Appearance of RMU
Button Switch
Name Description
SILENCE Key to MUTE alerting sound
LAMP TEST Key to TEST indicator LAMPs
LED Lamp
Name Description
TX1 Indicates that the TX1 is in Active state, i.e. on Aerial
TX2 Indicates that the TX2 is in Active state, i.e. on Aerial
NORMAL Indicates that the DVOR is in NORMAL operation
BYPASSED Indicates that the DVOR is in Bypassed state
ALARM Indicates that the DVOR is in ALARM condition
COMM Indicates that Communication error is occurred
RMU receives the status information of the system from LCU or RCMU and indicates
them on the 6 LED lamps on the front side. Also, it generates the warning sound when an
alarm occurs.
TXD RS485_TXD
RS485 Driver
RXD U301 RS485_RXD Alarm Sound Speaker out
Amp
RS485 Driver
14.7456MHz
Main Clock :
Alarm Sound
LED Control
MPU Sink Driver LED Bar
U300 U400 LED400~LED405
LED Drive
+5V SMPS
Alarm Sound
Microprocessor U300 executes most of the controls for RMU. U300 operates by receiving
the clock of 14.7456 MHz from the crystal oscillator X300.
The communication to RCMU or LCU is made through the RS485 serial communication.
The serial communication ports built into U300 are used. The TTL output signals of U301
are converted into the RS485 level.
The control of LED lamps is made through the GPIO ports PC0~PC5 of U300.
RMU operates by receiving the power of 5V from the built-in power supply unit (SMPS).
Chapter 4. Antenna
4.1. Overview
Figure 4-1 shows the antenna system of MARU 220.
Sideband Antenna
Antenna
Counterpoise
Counterpoise has a circular metal structure. The signals radiated below the horizontal plane
of an antenna radiation element from the general installation environment are randomly
reflected on an uneven surface and causes multiple path interferences. Counterpoise
prevents the random reflection by functioning as a uniform reflection object on the
horizontal plane.
Counterpoise, as the support structure for the antenna mechanically installed, plays the role
of a reflective object electrically.
The parts of counterpoise are made of the melted zinc galvanizing iron and steel. Although
its height on the surface generally ranges from 2.4m to 6m, it can be changed according to
the environmental conditions. The radius is about 30m and this also can be changed
according to the conditions.
The carrier wave antenna and sideband antenna as shown in the figure 4-2 are arranged on
the counterpoise. When collocated with DME or TACAN, the DME or TACAN antenna is
Magnetic North
n
tio
lu
2 1 48 47
vo
3
4 46
re
5 45
of
n
6 44
io
ct
7 43
re
di
8 42
9 41
10 40
11 39
12 38
13 37
14 36
Carrier Antenna
15 35
16 34
17 33
18 32
19 31
20 30
21 29
22 28
23 24 25 26 27
Carrier wave antenna is used to radiate the carrier wave signals in the air.
In order to radiate Omni-directionally on a horizontal plane, the carrier wave antenna uses
the Alford loop type and is installed in the middle of the counterpoise.
When DME or TACAN is collocated, the DME or TACAN antenna can be installed above
the carrier wave antenna. When it is not appropriate to install the DME antenna due to the
installation position, the DME antenna can be installed on the side of the counterpoise.
Sideband Antenna
Sideband antenna is used to radiate the 9960Hz sub-carrier wave sideband signals in the air.
Same to the carrier wave antenna, the Alford loop type of sideband antenna is used to
radiate Omni-directional on the horizontal plane.
Forty-eight sideband antennas are installed in the interval of 7.5on the circle perimeter
6.76m (113 MHz standard) away from the carrier wave antenna.
In case of the sideband antenna, power is fed sequentially in the counter-clock direction to
have the rotational effect. Each sideband antenna, according to the sequence of power feed,
is numbered 1 to 48, starting from the antenna to the magnetic north with 1.
Field monitor antenna is used to monitor the aerial radiation of VOR signal.
As for the monitor antenna, the partially horizontal 4-element Yagi antenna is used.
MARU 220 DVOR uses the Alford loop antenna for the transmission of carrier wave and
sideband signals.
Alford loop antenna is partially horizontal and Omni-directional within the horizontal plane.
Also, it has higher radiation efficiency than other generic loop antennas, due to its wide
radiation face.
+90
-10
-20
-30
-40
-50
-60
-70
-80
180 0
-90
-10
-20
-30
-40
-50
-60
-70
-80
270 90
180
Same to the sideband antenna, carrier wave antenna uses the Alford loop antenna. Two
pipes of supporting the DME antenna are penetrated from above the Radome to the floor.
Pedestal
Radome
Radome is an antenna protection cover. Since it is made of the Fiber Reinforced Plastic
(FRP), Radome protects radiation elements and other fixtures from snow, rain and wind.
The Radome shape of sideband antenna is circular from the horizontal plane and conic
from the side. The Radome for carrier wave antenna differs from the sideband antenna in
that two pipes of supporting the DME antenna are penetrating and the upper cover is flat.
The lower cover is fixed to the pedestal together with the radiation elements and the upper
cover laid on top of the lower cover is fastened with 6 screws.
Pedestal
Pedestal is the structure of supporting and fixing the antenna. Since it is made of the melted
zinc galvanizing steel, it is not easily corroded and is designed to stand against a strong
wind of max 200km/h.
The lower end of pedestal is fixed to the ring above the counter and the upper end supports
the Radome cover. The Balun cable and matching stub is positioned in the empty space of
the pedestal.
Radiation Element
The Alford loop antenna consists of 4 elements in a half-wave (/2) length. Each radiation
element is folded in a triangular shape as shown in the following figure.
The respective parts of a-b and a-b form the folded half-wave (/2) dipole antenna. Two
half-wave dipole antennas are faced from each other.
The electric connection of two dipole antennas is crossed so that the electric distribution
makes a circular direction. As shown in the figure, a is connected to a and be is connected
to b.
The electric distribution makes a circle from the outside that forms 4 sides of the Alford
loop. It is because two half-wave elements are offset as the direction from the inner folded
part becomes opposite to each other. Accordingly, only the outside current distribution
forms the radiation pattern and the inner current distribution doesnt affect much on the
radiation pattern.
+
a b
b' a'
+
Disc Capacitor
Figure 4-7 Electric Distribution of Alford Loop Antenna Radiation Elements
Disc Capacitor
Disc capacitor is a parallel circular plate attached respectively near to the rapid electricity
application points of two dipole antennas that makes up the radiation element. The resonant
frequency can be finely adjusted by turning the circular disc to the left and right.
Matching Stub
To Antenna
l1
Positioning Piece
Tee Adaptor
Tuning Stub
l2
Feeder Cable
From Transmitter
The impedance matching job can be done by adjusting the length 11 of positioning piece
and the length l2 of tuning stub. Since the lengths are adjusted to the installation
frequency from the factory, it is not recommended to adjust it from the field.
Balun
Balun is the device that converts the unbalanced transmission line to the balanced
transmission line and vice versa.
Since Alford loop antenna has a dipole antenna structure that is basically symmetric, it has
to use the balanced transmission line. However, the coaxial cable used commonly has the
unbalanced characteristics. Therefore, the Balun of converting the unbalanced to the
balanced is needed.
MARU 220 uses the RG-214 coaxial cable Balun with the length /2. The signal that has
passed through /2 transmission line will have the phase reversed by 180from the
original signal. The signal reversed by 180can be obtained from the provided signal by
using these characteristics.
Also, since this Balun holds the 4:1 impedance conversion characteristics, it can convert
the antenna input impedance 300 to 75. By doing so, matching to the standard
transmission line impedance 50 becomes easier.
Balanced
Z=4Zo
/2 Balun Cable
Feeder Cable
Unbalanced
Z=Zo
Boom
Director Reflector
Director
Radiator
Mast
Technical Manual
Volume I
EQUIPMENT DESCRIPTION
Copyright 2009-2011 MOPIENS, Inc.
All rights reserved