Documente Academic
Documente Profesional
Documente Cultură
Applications of
MBBR
Technologies
Wastewater Technologies
Attached Growth Suspended Growth
Activated sludge
Static Fixed film Dynamic Fixed Film
Continuous treatment Batch Treatment
Trickling filters Rotating
Rope media biological
Web media contactors (RBC) Conventional Sequencing batch
Biological active Moving Bed Activated sludge reactors (SBR)
filters (BAF) Biofilm Reactors MLE nutrient Membrane Bio-
(MBBR) removal reactors (MBR)
Plastic seaweed Barden pho
type media process
Membrane Bio-
reactors (MBR)
PRELIMINARY
Wastewater
Treatment Clarifier
Residuals Clarifier
TERTIARY
C Secondary Sludge
Biosolids
Processing
and Disposal Clean Wastewater Effluent
Discharge to Receiving Waters
Fixed Film Technologies
Trickling filters are a
static, air phase
fixed film treatment
system.
MBBRs are
dynamic, water
phase fixed film
treatment systems
MBBR = Moving Bed Biofilm
Reactor
Headworks Bio Incs process is based on
the biofilm principle using polyethylene
carrier elements.
The carrier elements, which are less
dense than water,0.93-0.95 SG, provide a
large protected surface for bacteria
culture.
MBBR provides advantages of Activated
Sludge and Trickling Filter systems
without their disadvantages.
MBBR is one of the most documented
processes with many technical
publications and presentations.
Dynamic Water Phase Fixed
Films
No problems with odors, snails or red-worms as in air phase fixed films.
Easier transfer of contaminants and oxygen to the biomass.
Biofilm thickness is maintained and controlled by continuous sloughing created
by the aeration-mixing process.
NO attrition of media plants 20 years old are still using original media
Stagnant Liquor
Biofilm Growth on Media
Mixing energy controls the biological thickness
Nitrifiers
BOD
More Than Just Plastic
15+ Years
of R&D
Successfu
Customiza
l
ble
Installatio Solutions
ns
Process
Virgin
Design
HDPE
Experts
Superior
Media
Compositi
on
Customizable Processes
Whats the Difference?
IFAS MBBR
Integrated Fixed Film Activated Sludge Moving Bed Biofilm Reactor
Temperature
k T = 1,07(T-10) (when T = 5 10 oC)
k T = 1,06(T-10) (when T = 10 - 20 oC)
Key Components: MBBR
Retention Sieves
Aeration Grid
Activecell Media
Features: BOD/COD
Single pass treatment Reduction
No operational adjustments
Multiple applications
Denitrification
BOD / COD Removal
High loads
Up to 6000 mg/l
Small foot print
Single pass treatment
No recycle
No operator adjustments
Biology self regulating
Low BOD effluent
50% to 80 % reduction in 30 minutes
< 10 mg/l BOD (after clarification)
IFAS Applications
C)
(works best at temperatures < 25
Existing Plant
BOD & TSS = 30 mg/L
Clarification
D D
Eff.
TN >8 mg/L
D
Pre- BOD Reduction Nitrification Post
D-nitrification D-nitrification
Waste
Sludge
Return Sludge
D
D
Biological Phosphorous
Removal
Decreases tank volume required for BOD/COD and Nitrification
allowing room for Bio-P and De-nitrification.
D
Footprint Comparison
Tricking Filter vs. MBBR
3500
3000
Foot print, m2
2500
2000
1500
1000
500
MBBR+DAF
MBBR + CLARIFIER
ASP + CLARIFIER
RBC vs MBBR
Example Plant with 5000 m3/d design flow:
Influent: BOD: 600mg/l, COD: 1000 mg/l, TSS 600 mg/l
Effluent: BOD: 50 mg/l, COD: 80 mg/l, TSS 60 mg/l
Al Balad, Jeddah
Tertiary
Treatment
(Sandfilter)
DAF
(Clarifier) Screen
EFFLUENT
RECYCLED FLOW
Current m3/d
Design Effluent Quality:
? RETENTION SCREENS
NITRIFYING REACTOR
EXISTING EFFLUENT
Capacity NEW RETENTION SCREEN
2 NITRIFYING REACTOR
Effluent Quality: NEW BAFFLE WALL
BOD REACTOR
10/10/3* EXISTING
SURFACE
Capacity AERATORS
EXISTING EFFLUENT
3
Effluent Quality: EXISTING RAS
EXISTING RAS
BOD REACTOR
NEW WALL WITH
NEW SECTION OF WALL RETENTION SCREENS
BOD REACTOR
NEW INFLUENT AERATION GRIDS NEW WALL WITH
RETENTION SCREENS
Option 1 Option 3
NEW EFFLUENT
RETENTION SCREENS
Options for Upgrading Carousel System
AERATION GRIDS
1 2 3
EXISTING INFLUENT
Increase in Treatment Capacity 2X 4X 2X
RCCL Enchantment of the Seas RCCL Jewel of the Seas RCCL Radiance of the Seas
Self regulating, no Self regulating, no Operator adjusts MLSS Operator adjusts MLSS
operator adjustments operator adjustments levels levels
Single pass flow Single pass flow MLSS sludge recycled May or may not require
through through back through plant MLSS recycle
???
Questions?
International
Headquarters
800 Wilcrest Dr, Suite
340
Houston, TX 77042
hwbio@headworksusa.
www.headworksbio.com
com