Sunteți pe pagina 1din 39

Dyna Doctor Manuals

SMMS/SHRM ,
MiNi-SMMS

1
The Dyna Doctor software is designed for
SMMS/SHRM, MiNi-SMMS individually.
** Can be operated on Windows 2000 / XP
These programs require Office 2000 or later version.
ns
ctio
o f u* Monitoring function for operating conditions
n
Tw *Test report making function of commissioning.
Dyna Adapter Kit
**Should be used with
Dyna-kit (adapter) for
Modular Multi Series
SMMS/SHRM/MiNi-SMMS use same one
MMS uses another one

2
USB converter
* If your PC doesnt have RS-232C port,
please use serial converter from RS-232C to USB
* When you use this converter, set up COM part

My computer
Property
* Match the COM setting to Hardware Tab
computers recognition. Device Manager
Port

MATCH!

3
DynaDoctor software install procedure (1)
Important: Before start install step, please follow below.
1. If you have installed old version software,
Please remove old one before installing new version.
( SMMS/SHRM : ver.1.32 is the newest )
( MiNi-SMMS : ver.1.30 is the newest )

notes:
You can keep your original data folder
at old folder even if you need to uninstall
old version program.

2. When its first time to install these Dyna Doctor


programs, please go to next page.
** Its no problem to install two or more kinds of Dyna Doctors to same PC.
m ple
a
Ex @ SMMS/SHRM and Digital Inverter Installing to One PC is O.K
@ SMMS/SHRM ver.1.25 and ver.1.32 Installing to One PC is not O.K
4
DynaDoctor software install procedure (2)-a
SMMS/SHRM Dyna Doctor
When your PC is installed IE, If installation display doesnt launch,
this display will automatically please open D drive manually.
appear.

Please select installed language as you need.


The selected language is applicable to only test report format.
5
DynaDoctor software install procedure (2)-b
MiNi-SMMS Dyna Doctor
1. Run [set-up.exe] program

2.Push [ Next ]

Automatically start set-up


wizard process.

6
DynaDoctor software install procedure (3)
Please input the password,
which is provided to each country or company by Toshiba .
1) Input your password
*case-sensitive:
carefully input with
capital or small letter.
(depend on your password)

2)Push [ Password check ]

If password is correct,
[ Password check ] button
changes to disable, and
[ Next ] button changes to enable.
if not change,
please input your password again.

3)Push [ Next ]
7
DynaDoctor software install procedure (4)

Recommend:
1) Please bestow the folder name with English character
if you make your original folder.
2)Please make the your original folder at [ Program files] folder structure.

Push [ Install ] button.


8
DynaDoctor software install procedure (5)

1) Please wait a few minutes .

2) When installed completely,


show display as right.
Push [ Finish ] button.

9
1. Dynadoctor
Function

10
1-1. Caution for this program
* There are three kinds of Software for Modular Multi Series
* There are two kinds of Adapter, for MMS and
SMMS/SHRM/MiNi-SMMS

Unit
SMMS MiNi MMS
SHRM SMMS
SMMS
Software

SHRM
MiNi
* * For MiNi-SMMS
SMMS / SHRM.
SMMS
MMS
* *
SMMS/SHRM
* *
MiNi-SMMS
*
Kit

MMS
* * *
For MMS
11
1-2-a. How to Connect the Dyna-kit to SMMS/SHRM

Dyna-kit is
connectable to
CDU.
CDU front E-Box

Take off the


front cabinet,
E-box cover.

E-box inside Connecting point

Connect the
dyna Doctor kit
adapter to CN800.
dyna-kit CN800
12
1-2-b. How to Connect a Dyna-kit to MiNi-SMMS
Dyna-kit is
connectable to CDU.

Take off the


front cabinet,
E-box cover.

Connecting point

Connect the
dyna Doctor kit
adapter to CN800.
dyna-kit CN800
13
1-3. Function & How to use
On the start up display , you can select function.
Data sampling, analysis Select Unit name tab
Test report draw up Make report with recorded data

14
1-4. Data sampling time & com port setting

Enter file name


and comment.

Select data folder

SMMS, MiNi-SMMS SHRM

Select the sampling time.

Recommend as ,
monitoring :10sec 1 min.
cycle judge : 5--10sec.
long time record: 210min.
Select the input Select the input (max 1000 data)
COM port. COM port.
(usually COM1) (usually COM1)
Take the MSB mark off 15
1-5-a. System configuration of SMMS/SHRM
Display
selection
button
Outdoor units change to ref. cycle diagram
number and
operation Hz.
Indoor HP and
operation mode.

At first, connected outdoor / indoor with capacity will automatically be displayed.


16
1-5-b. System configuration of MiNi-SMMS

Display
selection
button
Outdoor units change to ref. cycle diagram
information
Indoor HP and
operation mode.

17
1-6-a. Refrigerant cycle diagram of SMMS/SHRM

Outdoor cycle
show
comp, valve condition
refrigerant flow
temperature etc.

You can watch


Indoor cycle other indoor units
by scroll button

18
1-6-b. Refrigerant cycle diagram of MiNi-SMMS

Outdoor cycle
show
comp, valve condition
refrigerant flow
temperature etc.

You can watch


Indoor cycle other indoor units
by scroll button

19
1-7-a. Cycle diagram details of SMMS/SHRM
Time selector for record data

Indoor units
select button

20
1-7-b. Cycle diagram details of MiNi-SMMS
Time selector for record data

Indoor units
select button

21
1-8. System data table
Change to detailed
data of indoor units

Display
selection
button

Outdoor s
Indoor s

This data is helpful to check cycle condition 22


1-9. System detailed data of indoor units

show each indoors HP / operation mode / fan


operation mode / sensor value / error check code.

23
1-10. Outdoor Graph (graph drawing function by saved data.)

By selected item,
Select graph item automatically graph will be drawn.
for each outdoor unit.
24
1-11.Indoor Graph
Select graph item
from each indoor unit.

By selected item,
automatically graph
will be drawn.

25
1-12. System control data

Select by
dropdown menu.
Menu System Data List

Show system control detail.


(ex. release operation)

26
1-13. Check code List

You can refer error


code list on display.

27
2. Test report making
&
data record function

28
2-1. Report function select

Push this button Push this button

After pushing this button,


automatically go to report format

Select SMMS or
SHRM(1 or 2 series)
29
2-2. Project / Site data sheet
Testing period

Project / site
data

Customer
data
Test persons
comments

Test person
data

Please fill up the above table for commissioning / your service record. 30
2-3. Saved data search function
saved data search
by report No.
if blank, show all report list.
by Project / site name
by testing period (date)
by Customer name

31
2-4. Test result (Outdoor)
Outdoor units
(1)Installed place
(2)model name input
(3)ser. number input
(1)

(2) (3)

Test result input

Record the value


or select judge
item by pulldown
menu.

32
2-5. Test result (Indoor)
Indoor units (1)Qty input
& input all (2)install place (3) model name (4)ser. number

(1)

Power line
check result
(2)
(3) (4)

Test result input

Record the value


or select judge
item by pulldown
menu.

33
2-6. Data sheet selection Graph item
selection
can select
attachment data
sheet as,
(1)R cycle graph
(2)system data
(3)Indoor data
(4)Outdoor data
(5)Signal diagram
(6) R cycle diagram

Preview window

34
2-7. Test report Outdoor data table

Cover page

35
Indoor data Indoor data
(model name /Location/ser.no.)

36
System diagram / R cycle diagram R cycle graph / System data table

37
Indoor data table / Outdoor condition graph

38
END
39