Sunteți pe pagina 1din 5

 

 
Data Sheet

Applicator Sizing - Condensed (Flow)


 
Project
Project ssp
C.Project No.
Customer:
TAG ---
Timestamp ---
Review number ---
Sales order number
Contact person
eMail:
Phone
Fax
 
General Parameters Operating Conditions
Fluid Coffee extract with 8% product concentration minimum nominal maximum
State Liquid Requested Flow 6 004 7 200 8 500 l/h
Character Emulsion Pressure 3.5 kg/cm2_g
Abrasivity Not abrasive Temperature 120 °C
Fluid Group (PED) Normal Fluid (Fluid group 2) Density 0.9971 SG
Fluid Type Newtonian Viscosity 0.2994 cP
Atmospheric Pressure 1.0132 bar_a Sound velocity 1 571 1 533 1 533 m/s
Standard EN/DIN/ISO Pressure (min/max) 3 3.5 kg/cm2_g
Temp. (min/max) 80 120 °C
Vapor Pressure 0.4691 2.065 2.065 kg/cm2_a

Flowmeter Operating Conditions


Flowmeter Promag 50H minimum nominal maximum
Flow Principle Electromagnetic Requested Flow 6 004 7 200 8 500 l/h
Extended order code 50H40-V***P Velocity 1.704 2.044 2.413 m/s
Meter Size DN 40 Pressure loss 0 0 0 g/cm2
Operating range min. 0   l/h Measured error 0.56 0.55 0.54 %
Operating range max. 42 000   l/h Vol.***
Material (sensor) * PFA-Liner (-20...+150°C) Measured error Spec. 0.32 0.3 0.28 %
Process connection* PN 16 316L, 1.4404 Weld nipple pipe for gasket Volume***

PED category ** : In observance of the selected process Reynolds No. 240 230
conditions and medium, Applicator categorizes
this application as PED Art.4.3. Applicator
suggests an instrument without PED option.

*The user is responsible for the selection of process-wetted materials


in view of their corrosion resistance. Endress+Hauser makes no
guarantees and assumes no liability for the corrosion resistance of the
materials selected here for the application described above.
** The PED category is an Endress+Hauser recommendation and
depends on the fluid category, process data as well from the max.
permissible pressure of the selected pressure rating.The fluids of the
Applicator data base are classified to 67/548/EWG.
***For error calculation, the specified reference conditions for the
calibration of the flowmeter according to ISO/IEC 17025 apply. Further
information in technical documentation.

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The
results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

 
Print date: 27.10.2016 12:32 PM -1/5-
Applicator®: 10.24.03 / 162
Applicator Sizing - Flow
Project : ssp
Customer: C.Project No.:
Contact person: Phone: Fax:
eMail:

TAG : ---
Timestamp: --- Review number: ---
Sales order number:

Fluid properties sheet


Fluid
Fluid name Coffee extract with 8% product concentration State Liquid
Chemical formula Calculation standard Supporting Points

Fluid description
Solid content 0 %
Medium character Emulsion
Abrasivity Not abrasive
Conductivity more than 50 µS/cm
Fluid group (PED) Normal Fluid (Fluid group 2)
Fluid Type Newtonian

Basic fluid parameters


Tc (Critical temperature) 374.1   °C Tm (Melting point) -0.96   °C
Pc (Critical pressure) 225.562   kg/cm2 Tb (Boiling point) 100   °C
Heating value 0   kWh/Nm3
Temperature / Viscosity Temperature / Density
Temperature   Viscosity   Temperature   Density  
1    20 °C 2 cP 1    4.4 °C 1.033 SG
2    50 °C 1 cP 2    38.9 °C 1.022 SG
Temperature / Heat capacity  
Temperature   Thermal capacity  
1    10 °C 0 kJ/(kg*K)
2    100 °C 0 kJ/(kg*K)

Calculated results
Density nom. 0.9971   SG Pressure nom. 3.5   kg/cm2_g
Viscosity nom. 0.2994   cP Temperature nom. 120   °C
Sound velocity nom. 1 533   m/s
Vapor pressure nom. 2.065   kg/cm2_a
Thermal expansion coeff. Beta P 0.0003
Viscosity coefficient AL -6.773
Viscosity coefficient BL 2 188.903
 
Reference values:   Normal conditions (SI): Standard conditions (US):
Atmospheric pressure 1.0132   bar_a Atmospheric pressure 1.0132   bar_a

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The
results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

 
Print date: 27.10.2016 12:32 PM -2/5-
Applicator®: 10.24.03 / 162
Applicator Sizing - Flow
Project : ssp
Customer: C.Project No.:
Contact person: Phone: Fax:
eMail:

TAG : ---
Timestamp: --- Review number: ---
Sales order number:

Tri-Size Sheet
General Parameters
Fluid Coffee extract with 8% product
concentration
State Liquid
Character Emulsion Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Normal Fluid (Fluid group 2)
Fluid Type Newtonian

Sizing and Calculated Results


Next Smaller Size Current Size Next Bigger Size
Flow meter Promag 50H Promag 50H Promag 50H
Flow Principle Electromagnetic Electromagnetic Electromagnetic
Meter Size DN 25 DN 40 DN 50
Process connection* PN 40 EN 1092-1, 1.4404/316L PN 16 316L, 1.4404 PN 25 ISO 2037, 1.4404/316L
Operating range min. 0 0 0 l/h
Operating range max. 18 000 42 000 66 000 l/h
Velocity at req. Flow min. 3.141 1.704 0.918 m/s
Velocity at req. Flow nom. 3.767 2.044 1.101 m/s
Velocity at req. Flow max. 4.447 2.413 1.299 m/s
Pressure loss at req. Flow min. 0 0 0 g/cm2
Pressure loss at req. Flow nom. 0 0 0 g/cm2
Pressure loss at req. Flow max. 0 0 0 g/cm2
Meas. error Vol. at req. Flow min.*** 0.53 0.56 0.61 %
Meas. error Vol. at req. Flow nom.*** 0.53 0.55 0.59 %
Meas. error Vol. at req. Flow max.*** 0.52 0.54 0.58 %
Meas. error Spec. Vol. at req. Flow min.*** 0.26 0.32 0.42 %
Meas. error Spec. Vol. at req. Flow nom.*** 0.25 0.3 0.38 %
Meas. error Spec. Vol. at req. Flow max.*** 0.24 0.28 0.35 %
Reynolds No. 326 158 240 230 176 302
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The
results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

 
Print date: 27.10.2016 12:32 PM -3/5-
Applicator®: 10.24.03 / 162
Applicator Sizing - Flow
Project : ssp
Customer: C.Project No.:
Contact person: Phone: Fax:
eMail:

TAG : ---
Timestamp: --- Review number: ---
Sales order number:

Chart Sheet
Flowmeter: Promag 50H
Flow Principle Electromagnetic Fluid Coffee extract with 8% product concentration
Meter Size DN 40 Pressure 3.5 kg/cm2_g
Operating range min. 0   l/h Temperature 120   °C
Operating range max. 42 000   l/h Density 0.9971   SG
Viscosity 0.2994   cP

Flow rate(%) Flow rate (l/h) Measured error Volume(%) Meas. error spec. Vol.(%)
10 4 200 0.584 0.368
20 8 400 0.542 0.284
30 12 600 0.528 0.256
40 16 800 0.521 0.242
50 21 000 0.517 0.234
60 25 200 0.514 0.228
70 29 400 0.512 0.224
80 33 600 0.51 0.221
90 37 800 0.509 0.219
100 42 000 0.508 0.217

***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The
results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

 
Print date: 27.10.2016 12:32 PM -4/5-
Applicator®: 10.24.03 / 162
Applicator Sizing - Flow
Project : ssp
Customer: C.Project No.:
Contact person: Phone: Fax:
eMail:

TAG : ---
Timestamp: --- Review number: ---
Sales order number:

Corrosion Information
General Parameters
Fluid Coffee extract with 8% product Abrasivity Not abrasive
concentration
State Liquid
Character Emulsion Flow Principle Electromagnetic

Interpretation of Data, (M) Material:


A: resistant, 0.05 mm/y (0.002 inches/y)
B: insufficient resistant, 0.5 mm/y (0.02 inches/y)
C: not resistant, 1.3 mm/y (0.05 inches/y)
NR: not recommended
U: unknown

Interpretation of Data, (P) Plastics:


A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/y
B: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/y
C: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/y
NR: not recommended
U: unknown
Temperature
Material (Sensor) * minimum80°C nominal : 120°C maximum : 120°C
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The
results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

 
Print date: 27.10.2016 12:32 PM -5/5-
Applicator®: 10.24.03 / 162