JINDAL POWER LIMITED

CHECKLISTS
Doc. No. TMD/CL/004
TITLE : CHECKLIST FOR PREVENTIVE MAINTENANCE OF EQUIPMENTS Issue No. / Date 01 / 01-09-2008
TG & BOP MAINTENANCE DEPARTMENT Rev No. / Date 00 / 01-09-2008
UNIT : EQUIPMENT : CONDENSER ON LOAD TUBE CLEANING PUMP
WORK ORDER NO. : DATE :

PERMIT NO. : PTW ISSUE DATE : PTW CLOSING DATE :

Sl. Design Actual


Work Instructions Frequency Remarks
No. Value Value
Work to be done/carried out when the equipment is isolated
1 Carry out external cleaning of equipment. Monthly

Check all joints for leakages if any arrest it either by tightening or by replacing the
2 Monthly
glands.
Check all holding down bolts for tightness & take corrective action if required.
3 Monthly

Check coupling spider for damage, if necessary replace it.


4 Monthly

5 Check the recirculation pump oil level, if level is low top-up. Monthly

6 Check the tightness of coupling bolts. Monthly


7 Check gland leakages if any arrest it if leakage is to be observed, same to be attended Monthly
either by replacing
Checking the glands
of alignment of Pumpor with
by tightening
Motor andit. do the necessary correction if required.
8 Quarterly

Spill over oil / water / grease / cotton waste / etc in surrounding area and floor to be
9 Monthly
cleaned and disposed

Signature of Contractor Signature of JPL Engineer Signature of JPL Engineer in charge


Page No. : 01

Prepared By : Reviewed & Approved By : HOD