Stability Analysis of Spread footings

Input Data

Footing ID 1651A
Pedestal size along X, Cx 1.05 m
Pedestal size along y, cy 1.05 m
Footing Length along X axis, L 3.2 m
Footing width along Y axis, B 3.2 m
Footing Depth, D 0.35 m
Service Axial Load on the Footing , Ps -286 kN * +ve for Compressive Force and -ve for Uplift force
Moment at TOF about X axis 439 KNm * Clock wise Moment positive
Moment at TOF about Y axis 439 KNm * Clock wise Moment positive
Shear at TOF along X axis 102 kN * TOF=Top of Footing,NGL-Natural Ground Level
Shear at TOF along Y axis 102 kN
Embedment from NGL to TOF 3.65 m

Check For Overturning

Overtuning Moment,Mo
About X axis
Overtuning Moment Mox 439 KNm
Overturning Moment due to shear 35.7 KNm
Total Mox 474.7 KNm
About y axis
Overtuning Moment ,Moy 439 KNm
Overturning Moment due to shear 35.7 KNm
Total Moy 474.7 KNm
Resisting Moment, Mr
Footing Weight 86.016 kN
Soil weight above footing 600.33375 kN
About X axis
Due to Axial Force -457.6 KNm
Due to Footing weight 137.6256 KNm
Due to Soil weight 960.534 KNm
Total Mrx 640.5596 KNm
About Y axis
Due to Axial Force -457.6 KNm
Due to Footing weight 137.6256 KNm
Due to Soil weight 960.534 KNm
Total Mrx 640.5596 KNm
F.O.S About X axis 1.35
F.O.S About Y axis 1.35 UNSAFE IN OVERTURNING
Check For Uplift
Table 1
Uplift Force, P 286 kN Coarse Grained
Resisting Force, Pr 686.34975 kN Coarse Grained Silty
F.O.S 2.40 SAFE Silty

Check For Sliding

Friction Coefficient 0.35 * Take from Table 1


Sliding Force, Hx 102
Sliding Force, Hy 102
Resisting force due to friction 140.12
Passive pressure coefficient, Kp 2.67
Passive Resisting force in X 205.89
Passive Resisting force in Y 205.89
F. O. S along X 3.39
F. O. S along Y 3.39 SAFE

Ly X
Cy
Cx

Lx
ssive Force and -ve for Uplift force

ting,NGL-Natural Ground Level

VERTURNING
Table 1
Coarse Grained 0.55
Coarse Grained Silty 0.45
Silty 0.35