Sunteți pe pagina 1din 4

1- Attachado na cds (sem layer map)

ERROR (XSTRM-74): Translation cannot be continued because layer mapping cannot be


done. This is because the layer map is not specified by the '-layerMap' option and the
technology library 'cdsDefTechLib' also does not contain 'cdsDefTechLib.layermap'.
Additionally, automatic layer mapping cannot be done because the technology file is
opened in read-only mode due to the library 'csm13' being attached to it. Use a layer
map file to continue.

2- Attachado na cds (com layer map)

WARNING (XSTRM-75): Target library 'csm13' is attached to the technology library


'cdsDefTechLib'. Therefore, the technology file is opened in read-only mode. All the
undefined layer-purpose pairs will be dropped.
WARNING (XSTRM-107): Existing cells in the target library will be overwritten if the
cell names in the Stream file and the target library are the same. To prevent this, set
the '-writeMode' option to 'noOverwrite'.
INFO (XSTRM-217): Reading the layer map file,
/home/Denner.Almeida/cadence/GF_130_HP/8HP/aci/sc-
x/gds2/csm13.gds2.layermap

Summary of Options:
library csm13
strmFile
/home/Denner.Almeida/cadence/GF_130_HP/8HP/aci/sc-x/gds2/csm13.gds2
logFile strmIn.log
view layout
case Preserve
layerMap
/home/Denner.Almeida/cadence/GF_130_HP/8HP/aci/sc-
x/gds2/csm13.gds2.layermap
propSeparator ,

ERROR (XSTRM-166): Translation Failed - Parser: File


'/home/Denner.Almeida/cadence/GF_130_HP/8HP/aci/sc-x/gds2/csm13.gds2'
specified as a GDSII file, does not appear to be in GDSII format.
If problem persists, contact the Cadence Customer Support.

3- Attachado na bicmos8hp (sem layer map)

WARNING (XSTRM-75): Target library 'csm13' is attached to the technology library


'bicmos8hp'. Therefore, the technology file is opened in read-only mode. All the
undefined layer-purpose pairs will be dropped.
WARNING (XSTRM-107): Existing cells in the target library will be overwritten if the
cell names in the Stream file and the target library are the same. To prevent this, set
the '-writeMode' option to 'noOverwrite'.
INFO (XSTRM-217): Reading the layer map file,
/cadence/IBM_PDK/bicmos8hp/V1.6_3.1HP/cdslib/bicmos8hp/bicmos8hp.layermap
WARNING (XSTRM-31): Layer map file
'/cadence/IBM_PDK/bicmos8hp/V1.6_3.1HP/cdslib/bicmos8hp/bicmos8hp.layermap'
contains a duplicate entry for Stream layer:datatype '15:0' at line '95'. Therefore, this
entry will be ignored during translation.
WARNING (XSTRM-31): Layer map file
'/cadence/IBM_PDK/bicmos8hp/V1.6_3.1HP/cdslib/bicmos8hp/bicmos8hp.layermap'
contains a duplicate entry for Stream layer:datatype '15:0' at line '96'. Therefore, this
entry will be ignored during translation.
WARNING (XSTRM-31): Layer map file
'/cadence/IBM_PDK/bicmos8hp/V1.6_3.1HP/cdslib/bicmos8hp/bicmos8hp.layermap'
contains a duplicate entry for Stream layer:datatype '17:0' at line '129'. Therefore, this
entry will be ignored during translation.
WARNING (XSTRM-31): Layer map file
'/cadence/IBM_PDK/bicmos8hp/V1.6_3.1HP/cdslib/bicmos8hp/bicmos8hp.layermap'
contains a duplicate entry for Stream layer:datatype '17:0' at line '130'. Therefore, this
entry will be ignored during translation.
WARNING (XSTRM-31): Layer map file
'/cadence/IBM_PDK/bicmos8hp/V1.6_3.1HP/cdslib/bicmos8hp/bicmos8hp.layermap'
contains a duplicate entry for Stream layer:datatype '19:0' at line '162'. Therefore, this
entry will be ignored during translation.
WARNING (XSTRM-31): Layer map file
'/cadence/IBM_PDK/bicmos8hp/V1.6_3.1HP/cdslib/bicmos8hp/bicmos8hp.layermap'
contains a duplicate entry for Stream layer:datatype '19:0' at line '163'. Therefore, this
entry will be ignored during translation.
WARNING (XSTRM-31): Layer map file
'/cadence/IBM_PDK/bicmos8hp/V1.6_3.1HP/cdslib/bicmos8hp/bicmos8hp.layermap'
contains a duplicate entry for Stream layer:datatype '21:0' at line '195'. Therefore, this
entry will be ignored during translation.
WARNING (XSTRM-31): Layer map file
'/cadence/IBM_PDK/bicmos8hp/V1.6_3.1HP/cdslib/bicmos8hp/bicmos8hp.layermap'
contains a duplicate entry for Stream layer:datatype '21:0' at line '196'. Therefore, this
entry will be ignored during translation.
WARNING (XSTRM-31): Layer map file
'/cadence/IBM_PDK/bicmos8hp/V1.6_3.1HP/cdslib/bicmos8hp/bicmos8hp.layermap'
contains a duplicate entry for Stream layer:datatype '34:0' at line '238'. Therefore, this
entry will be ignored during translation.
WARNING (XSTRM-31): Layer map file
'/cadence/IBM_PDK/bicmos8hp/V1.6_3.1HP/cdslib/bicmos8hp/bicmos8hp.layermap'
contains a duplicate entry for Stream layer:datatype '34:0' at line '239'. Therefore, this
entry will be ignored during translation.
WARNING (XSTRM-31): Layer map file
'/cadence/IBM_PDK/bicmos8hp/V1.6_3.1HP/cdslib/bicmos8hp/bicmos8hp.layermap'
contains a duplicate entry for Stream layer:datatype '42:1' at line '291'. Therefore, this
entry will be ignored during translation.
WARNING (XSTRM-31): Layer map file
'/cadence/IBM_PDK/bicmos8hp/V1.6_3.1HP/cdslib/bicmos8hp/bicmos8hp.layermap'
contains a duplicate entry for Stream layer:datatype '42:1' at line '292'. Therefore, this
entry will be ignored during translation.
WARNING (XSTRM-31): Layer map file
'/cadence/IBM_PDK/bicmos8hp/V1.6_3.1HP/cdslib/bicmos8hp/bicmos8hp.layermap'
contains a duplicate entry for Stream layer:datatype '53:0' at line '321'. Therefore, this
entry will be ignored during translation.
WARNING (XSTRM-31): Layer map file
'/cadence/IBM_PDK/bicmos8hp/V1.6_3.1HP/cdslib/bicmos8hp/bicmos8hp.layermap'
contains a duplicate entry for Stream layer:datatype '53:0' at line '322'. Therefore, this
entry will be ignored during translation.
WARNING (XSTRM-31): Layer map file
'/cadence/IBM_PDK/bicmos8hp/V1.6_3.1HP/cdslib/bicmos8hp/bicmos8hp.layermap'
contains a duplicate entry for Stream layer:datatype '81:0' at line '387'. Therefore, this
entry will be ignored during translation.
WARNING (XSTRM-31): Layer map file
'/cadence/IBM_PDK/bicmos8hp/V1.6_3.1HP/cdslib/bicmos8hp/bicmos8hp.layermap'
contains a duplicate entry for Stream layer:datatype '81:0' at line '388'. Therefore, this
entry will be ignored during translation.
WARNING (XSTRM-31): Layer map file
'/cadence/IBM_PDK/bicmos8hp/V1.6_3.1HP/cdslib/bicmos8hp/bicmos8hp.layermap'
contains a duplicate entry for Stream layer:datatype '83:0' at line '403'. Therefore, this
entry will be ignored during translation.
WARNING (XSTRM-31): Layer map file
'/cadence/IBM_PDK/bicmos8hp/V1.6_3.1HP/cdslib/bicmos8hp/bicmos8hp.layermap'
contains a duplicate entry for Stream layer:datatype '83:0' at line '404'. Therefore, this
entry will be ignored during translation.
INFO (XSTRM-217): Reading the object map file,
/cadence/IBM_PDK/bicmos8hp/V1.6_3.1HP/cdslib/bicmos8hp/bicmos8hp.objectmap
INFO (XSTRM-163): You have not used the viaMap option. If a viaMap file,
corresponding techfile or technology library exist, then use the -viaMap option for
creating oaVia instances in the Streamed-In library. Using the -viaMap option improves
performance and VM usage of applications using the Streamed-In design. For details
on the viaMap option, refer to the "Design Data Translator's Reference" guide for
XStream.

Summary of Options:
library csm13
strmFile
/home/Denner.Almeida/cadence/GF_130_HP/8HP/aci/sc-x/gds2/csm13.gds2
logFile strmIn.log
view layout
case Preserve
layerMap
/cadence/IBM_PDK/bicmos8hp/V1.6_3.1HP/cdslib/bicmos8hp/bicmos8hp.laye
rmap
propSeparator ,
objectMap
/cadence/IBM_PDK/bicmos8hp/V1.6_3.1HP/cdslib/bicmos8hp/bicmos8hp.objectmap
ERROR (XSTRM-166): Translation Failed - Parser: File
'/home/Denner.Almeida/cadence/GF_130_HP/8HP/aci/sc-x/gds2/csm13.gds2'
specified as a GDSII file, does not appear to be in GDSII format.
If problem persists, contact the Cadence Customer Support.

4- Attachado na bicmos8hp (com layer map)

WARNING (XSTRM-75): Target library 'csm13' is attached to the technology library


'bicmos8hp'. Therefore, the technology file is opened in read-only mode. All the
undefined layer-purpose pairs will be dropped.
WARNING (XSTRM-107): Existing cells in the target library will be overwritten if the
cell names in the Stream file and the target library are the same. To prevent this, set
the '-writeMode' option to 'noOverwrite'.
INFO (XSTRM-217): Reading the layer map file,
/home/Denner.Almeida/cadence/GF_130_HP/8HP/aci/sc-
x/gds2/csm13.gds2.layermap
INFO (XSTRM-217): Reading the object map file,
/cadence/IBM_PDK/bicmos8hp/V1.6_3.1HP/cdslib/bicmos8hp/bicmos8hp.objectmap
INFO (XSTRM-163): You have not used the viaMap option. If a viaMap file,
corresponding techfile or technology library exist, then use the -viaMap option for
creating oaVia instances in the Streamed-In library. Using the -viaMap option improves
performance and VM usage of applications using the Streamed-In design. For details
on the viaMap option, refer to the "Design Data Translator's Reference" guide for
XStream.

Summary of Options:
library csm13
strmFile
/home/Denner.Almeida/cadence/GF_130_HP/8HP/aci/sc-x/gds2/csm13.gds2
logFile strmIn.log
view layout
case Preserve
layerMap
/home/Denner.Almeida/cadence/GF_130_HP/8HP/aci/sc-
x/gds2/csm13.gds2.layermap
propSeparator ,
objectMap
/cadence/IBM_PDK/bicmos8hp/V1.6_3.1HP/cdslib/bicmos8hp/bicmos8hp.objectmap

ERROR (XSTRM-166): Translation Failed - Parser: File


'/home/Denner.Almeida/cadence/GF_130_HP/8HP/aci/sc-x/gds2/csm13.gds2'
specified as a GDSII file, does not appear to be in GDSII format.
If problem persists, contact the Cadence Customer Support.