Sunteți pe pagina 1din 2

PR .t..

89 A
formerly S 1 22E

POST OFFICE El'K1-INEERING DEPARTMENT

SPECIFICATION PR 489~

FOR
CLOCK-UNITS GMT 34 AND GMT 35

ENGINEER-IN-cHIEF'S DRAWING NOS. P/T75, P/T76, P/T7'9 AND P/'180

ENGINEER-IN-cHIEF'S DIAGRAt'viS GMT 3W'1 AND GMT 35/1

NOTE:- Specification D 1000 shall be taken as forming part of this Specification.

~. GENERAL

Clock-unit, GMT 34 provides for the operation of 30 second and 1 second


electric pulse clocks, and for the distribution of 30 second, '6 second and 1
second pulses to the telephone apparatus.
Clock-unit, GMT 35 provides for the operation of 30 second electric-pulse
clocks.
Each unit compris~s the relative items shown in the Table of Components.
The relative drawings and specifications are specified therein.
TABLE OF COMPONENTS
I :
Item on Item on
Drg. N:>. Drg. No. Stock Title
Quantity ! Drg. Spec.
P/r..75 P/T 79 GMT 34 i GMT 35 No.
A
B
A
B
Clip No. 16
Capacitor MC No. 101
1 at 4 in. 1 at 1 i.n. 62576
8 2 9208
-
D742
c Jack No. 200 B/6N 1 -
61061 D 1-172
F
G D
Mounting, No.151/8J.H
Relay No. 3062
1
3 1
-
60302
9955
-
T 4512
H E 11
No. 3658 1 1 ... 9955 T 4512
K Resistor, Coil No.12)
(500 ohms) )
1 -9263 D 737
L H Resistor,;)ool No. 6) 8 2 9480 ...
(200 ohms
M Strip, Connexion,
No. 101 I 1 - 8207 D 528

N Label, No. 1 64 I 1 1 62556 -


-1-
I STA/36 Part, No. STA/36 I 10 STA/36 -
STA/37 tt No. STA/37 10 STA/37 -
0 Resistor, Coil No. 9)
(110 ohms)
I - I 9278 D 748
p .,
I Relay, No. 5356 I 1 - I I
9955 T 4512
! I I
! I !
--
Both Clock-units shall be constructed strictlY in accordance with their
.respective drawings and diagrams.
2. WIRING
The wiring of the units shall be in accordance .;ith Diagram GMT 34/1 or
GMT 35/1 and shall be wired with Wire 1 P •.V. 'J. No. 3A; 1W/6! lh.. to
Spe cifi.ca tion Oil 109.
Bltta 1~6/P

' Specification PR 4-89-i~
Page 2
The I'!egative cattery >"dring run shall be coloured Bleck 1 and the earth
wiring run sl:all l::e coloured r ed. ni :d ng to e.dj G:cent t ·a gs sr.all be Wire ,
Ccpper 1 T.inned1 20 S. W.G. All ~ther wiring, Green.
Each unit shall be wired for the maximum ecpipment; the wire s shall be
neatly laced into a form and provided with sufficient slack to allow of each
mounting being moved through an angl e of 90° to the baseboard. Wire s not
actually u sed shall be neatly laced in the cable form in such a posit ion that
they are readily avail able when requir ed.
3. INSULATION RESISTANCE
The insula tion r esistance between any two points that are not r equired to
be electrically connected shall be not l e ss than 1000 megohms when tested with
2.50 vol t s n.c.
4• SAMPLES
A:n ad:vame sample of each unit shall be submitted for appr oval bef ore pro-
ceeding with the manufac ture of t he bulk supplie s, unless a sample of identical
c onstruction has.been previously app roved by the Enginee ring Department, P Branch.

5• MARKIIGS
Typical markings:- ~/ 2 shall be stamped on the base as shown on
Drawings No s . P/.r 7.5 and P)r 79.
(The l etters FH are typical, c:nd sl:>itll be substituted by the approved code letters
.all oca ted to the manufacturer. )
In addition a Label , No. 1 ~ engrav~d with the p.o. stoc k list t itle and the
number of the diagr am, viz:
Clock- unit Cl ock-unit
GMT34 GMT3.5
o :~
Dgm. GMT34/1 • ••• Dgm. GMT3.5/1••• •
shall be affixed to the lid of the case in the position shown on Drawing Nos.
P/T7B and P/T79 respectivel y .
SCHEIXJLE OF DRAWINGS, DIAGRAMS AND SPECIFICATI ONS
PROPER TO THIS SPECIFICATION

Drawing No. Diagram No. Specification No.

9208 GMT 34/1 cw 109


9263 GMT 3.5/1 D-.528
9278 D 737
9480 D 742
8207 D748
995.5 D1000
60302 D 1172
T 4.512
61061
l?/T7'5 ...; ..
P/T76 -
P/T79
PjT80
62.5.56
I 62.576 I

I
1
STA/36
STA/37
j
! !

His tory . Open issue . Transferr ed f rom S Branch. Four drawings renumbered.
Issue A. Minor errors corre cted.

File Ref: P2/4/73/.50/09


March 1960.
Power Branch,
Engineering Department,
London ; ·E. c. 2.
Rota 14426/P