EA1 Rigid Conduit Fittings EA1

Conduit End Bells


Threaded for Rigid Conduit & IMC

Type TNS Trade Dimensions in Inches


Size Catalog Overall Bell Height Max.
Use: (Inches) Number (A) (B) Dia.
For threaded rigid conduit or IMC.
11¼2 TNS-150 21/16 11/2 41/4
2 TNS-200 21/16 11/2 45/8
Features: 21/2 TNS-250 23/8 15/8 5
• Provides a smooth, rounded pulling 3 TNS-300 31/8 23/8 63/8
surface, preventing damage to cable sheath
or insulation. 31/2 TNS-350 31/4 21/2 67/8
4 TNS-400 39/16 27/8 73/8
• Slots are provided for attaching to 5 TNS-500 39/16 27/8 83/8
concrete forms. 6 TNS-600 37/8 27/8 95/8
Type TNS
Material/Finish:
Malleable or Ductile Iron/
Hot Dip Galvanized

Effective February, 2002 7770 N. Frontage Road


Copyright 2002 Printed in U.S.A. Skokie, Illinois 60077
EA2 Rigid Conduit Fittings EA2
Hex Reducing Bushings
Threaded for Rigid Conduit & IMC

Type 300R Dimensions in Inches


Max. Dim.
Provided with hex shoulder Trade Size Catalog Across Thread Flange
(inches) Number Corners Length Thickness
Material/Finish: 1
/2 - 3/8 320-R 11/8 1
/2 5
/32
Malleable Iron/Zinc Electroplated 3
/4 - 1/2 321-R 17/16 5
/8 3
/16

Third Party Certification: 1 - 3/4 322-R 15/8 5


/8 3
/16
1 - 1/2 323-R 15/8 11
/16 5
/32
UL Listed: E-11853
11/4 - 1/2 324-R 115/16 3
/4 3
/16
11/4 - 3/4 325-R 115/16 3
/4 3
/16
CSA Certified: 9795 11/4 - 1 326-R 115/16 3
/4 3
/16

11/2 - 11/4 327-R 23/8 15


/16 5
/16
11/2 - 1 328-R 23/8 15
/16 5
/16 Type 300R
Applicable Third Party Standards: 11/2 - 3
/4 329-R 23/8 15
/16 5
/16
UL Standard: 514B 11/2 - 1
/2 330-R 23/8 15
/16 5
/16
CSA Standard: C22.2 No. 18
2 - 11/2 331-R 23/4 15
/16 5
/16
Fed. Spec: W-F-408E 2 -11/4 332-R 23/4 15
/16 5
/16
NEMA: FB-1 2 -1 333-R 23/4 15
/16 5
/16
2 - 3/4 334-R 23/4 15
/16 5
/16
2 - 1/2 335-R 23/4 15
/16 5
/16
21/2 - 2 336-R 31/4 15
/16 7
/16
21/2 - 11/2 337-R 31/4 15
/16 7
/16
21/2 - 1 339-R 31/4 15
/16 7
/16

3 - 11/2 340-R 315/16 11/16 1


/2
3-2 341-R 313/16 11/8 1
/2
3 - 21/2 342-R 315/16 11/16 1
/2

31/2 - 3 349-R 47/16 11/2 1


/2
31/2 - 21/2 350-R 47/16 11/2 1
/2
4 - 21/2 355-R 51/8 17/16 1
/2
4-3 356-R 53/8 11/4 1
/2
4 - 31/2 357-R 53/8 11/4 1
/2

Effective February, 2002 7770 N. Frontage Road


Copyright 2002 Printed in U.S.A. Skokie, Illinois 60077
EA5 Rigid Conduit Fittings EA5
Split Couplings™
For Threaded Rigid Conduit & IMC

Type SSP Trade Size Catalog Dimensions in Inches


(inches) Number Length Max. Width Dia.
Use:
A speed union for economically joining two /2
1
SSP-50 11/4 13/4 11/8
threaded rigid metal conduits. /4
3
SSP-75 11/4 2 15/16
1 SSP-100 15/8 25/8 13/4
Features:
• A neoprene gasket provides a concrete- 11/4 SSP-125 15/8 25/8 21/8
11/2 SSP-150 2 31/4 23/8
tight seal at the joint 2 SSP-200 21/16 31/2 23/4
• Use where conduit runs are closely
spaced 21/2 SSP-250 31/16 41/2 33/8
• Use where conduit is tight against wall, 3 SSP-300 33/16 5 4 Type SSP-150 — Type SSP-600
31/2 SSP-350 31/4 53/4 49/16
ceiling or other obstruction
• Use where conduit cannot be turned 4 SSP-400 33/8 61/4 51/8
5 SSP-500 31/2 71/4 63/8
Material/Finish: 6 SSP-600 4 85/8 71/2
SSP-100 thru SSP-600: Malleable or
Ductile Iron/Zinc Plated
SSP-50 and SSP-75: Steel/Zinc Plated

Optional Finish:
Mechanically Galvanized
Contact your local
representative for pricing and availability.
Type SSP-100 and SSP-125
Third Party Certification:
UL Listed: E-11853
UL Listed as Concretetight.

CSA Certified: 9795

Applicable Third Party Standards:


UL Standard: 514B Existing
CSA Standard: C22.2 No. 18 Conduit
NEMA: FB-1
Type SSP-50 and SSP-75
Installation Instructions:
The inside diameter of the split coupling is
greater than the outside diameter of the
conduit with which it is to be used. To
assemble - slip the coupling over one of the
threaded conduit ends, butt the two conduit
ends together, slide the coupling back over
the joint and tighten the hex nut(s). The
threaded interior of the split coupling match-
es with the conduit threads and makes a
close fitting mechanically rigid connection
with sufficient thermal capacity (I2T) to
carry ground fault currents equal to wire Application Illustration
sizes required by Underwriters Laboratories,
Inc. Standard 467 - Table IV, and National
Electrical Code Table 250.66.

Effective February, 2002 7770 N. Frontage Road


Copyright 2002 Printed in U.S.A. Skokie, Illinois 60077
EA6 Rigid Conduit Fittings EA6
3-Piece Couplings & Bushed Conduit Nipples
Threaded for Rigid Conduit & IMC

Type 4 Trade Size Catalog Overall Max.


(inches) Number Length Dia.
3-piece Coupling
Use:
/2
1
4-50 13/8 17/16
Couples conduit when neither can be /4
3
4-75 15/8 13/4
turned. 1 4-100 113/16 115/16

Features: 11/4 4-125 23/16 23/8


11/2 4-150 25/16 25/8
• Threaded (NPS) for rigid conduit and IMC 2 4-200 27/16 33/8
• Couples conduits when conduits can not Type 4
be turned 21/2 4-250 33/16 4
• Concretetight 3 4-300 35/16 43/16
31/2 4-350 31/2 51/8
Material/Finish: 4 4-400 33/4 51/2
Malleable Iron/Zinc Electroplated 5 4-500 311/16 67/8
6 4-600 45/16 81/4
Optional Finish:
Mechanically Galvanized
Contact your local representative for pricing
and availability.

Third Party Certification:


UL Listed: E-11853

CSA Certified: 9795

Type 7 Insulated Dimensions in Inches


Bushed Conduit Nipples Throat Max. Dia.
Trade Size Catalog Catalog Across Thread Flange
Use: (inches) Number Number Corners Length
Use through knockout to connect box to Thickness
conduit coupling. Use with a locknut to con-
nect two boxes side by side or back to 3
/8 7-38 --- 7
/8 1
/2 1
/8
back. Use with a locknut to connect fixture
1
/2 7-50 7-50T 11/8 1
/2 /16
3

3
/4 7-75 7-75T 1 /4
1 5
/8 /16
3
housings in continuous runs.
1 7-100 7-100T 13/4 5
/8 1
/4 Type 7
Features: 11/4 7-125 7-125T 21/8 7
/8 1
/4
• Available with Insulated Throat. 11/2 7-150 7-150T 21/2 1 /16
5

• With rigid conduit threads (NPS) 2 7-200 7-200T 3 1 /8


1 5
/16
21/2 7-250 7-250T 35/8 11/4 3
/8
Material/Finish: 3 7-300 7-300T 41/2 11/4 3
/8
Malleable Iron/Zinc Electroplated 31/2 7-350 7-350T 51/8 13/8 3
/8

4 7-400• 7-400T• 51/4 11/4 /16


7

Optional Finish: 5 7-500• 7-500T• 63/8 11/4 1


/2
Mechanically Galvanized
Contact your local representative for pricing •Not CSA Certified
and availability.

Third Party Certification:


UL Listed: E-11853

CSA Certified: 9795

Applicable Third Party Standards:


UL Standard: 514B
CSA Standard: C22.2 No. 18
Fed. Spec. W-F-408E
NEMA: FB-1

Effective February, 2002 7770 N. Frontage Road


Copyright 2002 Printed in U.S.A. Skokie, Illinois 60077
EA7 Rigid Conduit Fittings EA7
Compression Rigid Connectors & Couplings
For Threadless Rigid Conduit

Type 31 Insulated
Gland Compression Connectors Throat Dimensions in Inches
Trade Size Catalog Catalog Body Max Thread
(inches) Number Number Length Dia. Length
Use:
To connect threadless rigid conduit to boxes 1
/2 31-050 31-050T 3
/4 13/8 7
/16
and enclosures. 3
/4 31-075 31-075T 7
/8 19/16 7
/16
1 31-100 31-100T 1 /16
3
115/16 9
/16
Features: 11/4 31-125 31-125T 13/8 25/16 5
/8 Type 31-050 — Type 31-200
• Concretetight 11/2 31-150 31-150T 13/8 25/8 5
/8

• Male hub threads (NPS 1/2” through 2”; 2 31-200 31-200T 11/2 35/16 11
/16

NPT above 2”).


21/2 31-250• 31-250T• 21/8 41/32 1
3 31-300• 31-300T• 27/16 413/16 1
Material/Finish: 31/2 31-350• 31-350T• 25/8 51/2 13/16
Malleable Iron/Zinc Electroplated
4 31-400• 31-400T• 29/16 61/8 11/4
5 31-500• 31-500T• 23/16 73/8 11/8
Optional Finish: 6 31-600• 31-600T• 23/8 89/16 13/8
Mechanically Galvanized
Contact your local representative for pricing •Not UL Listed
and availability.
Type 31-250 — Type 31-600
Third Party Certification:
UL Listed: E-11853

Applicable Third Party Standards:


UL Standard: 514B
Fed. Spec: W-F-408E
NEMA: FB-1

Type 30 Trade Size Catalog Dimensions in inches


Gland Compression Couplings (inches) Number Length Max. Dia.

Use:
1
/2 30-050 111/16 13/8
3
/4 30-075 13/4 19/16
To couple sections of threadless rigid 1 30-100 115/16 115/16
conduit together.
11/4 30-125 21/2 25/16
Features: 11/2 30-150 29/16 25/8
2 30-200 27/8 35/16 Type 30-050 — Type 30-200
• Concretetight
21/2 30-250• 315/16 41/32
Material/Finish: 3 30-300• 45/16 413/16
Malleable Iron/Zinc Electroplated 31/2 30-350• 41/2 51/2
4 30-400• 49/16 61/8
Optional Finish: 5 30-500• 37/8 73/8
Mechanically Galvanized 6 30-600• 41/4 89/16
Contact your local
•Not UL Listed
representative for pricing and availability.

Third Party Certification: Type 30-250 — Type 30-600


UL Listed: E-11853

Applicable Third Party Standards:


UL Standard: 514B
Fed. Spec: W-F-408E
NEMA: FB-1

Effective February, 2002 7770 N. Frontage Road


Copyright 2002 Printed in U.S.A. Skokie, Illinois 60077
EA8 Rigid Conduit Fittings EA8
Set-Screw Rigid Connectors & Couplings
For Threadless Rigid Conduit & IMC

Type 28 Insulated
Throat Dimensions in Inches
Use: Trade Size Catalog Catalog Body Max Thread
To connect threadless rigid conduit to boxes (inches) Number Number Length Dia. Length
and enclosures. 1
/2 28-050 28-050T 31
/32 11/4 /16
7

3
/4 28-075 28-075T 13/16 17/16 /16
7

Features: 1 28-100 28-100T 1 /16


7
13/4 /32
17

• Concretetight.
• Available with insulated throat. 11/4 28-125 28-125T 19/16 21/8 /8
5
Type 28-050 — Type 28-200
• Male hub thread (NPS) 11/2 28-150 28-150T 13/4 23/8 /8
5

2 28-200 28-200T 17/8 27/8 /8


5

Material/Finish: 21/2 28-250 28-250T 21/8 39/16 1


Malleable Iron/Zinc Plated 3 28-300 28-300T 23/8 41/4 1
31/2 28-350 28-350T 23/4 43/4 11/8
Optional Finish: 4 28-400 28-400T 3 51/4 11/8
1
/2” - 11/2” Mechanically Galvanized 5 28-500 28-500T 4 63/4 11/4
2” - 6” Hot Dip Galvanized 6 28-600 28-600T 41/2 77/8 11/4
Contact your local representative for pricing
and availability.

Third Party Certification: Type 28-250 — Type 28-600


UL Listed: E-11853

Applicable Third Party Standards:


UL Standard: 514B
Fed. Spec: W-F-408E
NEMA: FB-1

Type 29 Trade Size Catalog Dimensions in Inches


(inches) Number Length Max. Dia.
Use:
To couple sections of threadless rigid 1
/2 29-050 13/4 11/4
conduit together.
3
/4 29-075 21/8 17/16
1 29-100 25/8 13/4
Features: 11/4 29-125 23/4 21/8
Concretetight 11/2 29-150 31/8 23/8
2 29-200 33/8 27/8 Type 29-050 — Type 29-200
Material/Finish:
21/2 29-250 37/8 39/16
Malleable Iron/Zinc Plated 3 29-300 43/8 47/32
31/2 29-350 5 43/4
Optional Finish:
Optional Finish: 4 29-400 51/2 51/4
5 29-500 71/2 63/4
1
/2” - 11/2” Mechanically Galvanized 6 29-600 81/2 77/8
2” - 6” Hot Dip Galvanized
Contact your local representative for pricing
and availability.

Third Party Certification:


UL Listed: E-11853 Type 29-250 — Type 29-600

Applicable Third Party Standards:


UL Standard: 514B
Fed. Spec: W-F-408E
NEMA: FB-1

Effective February, 2002 7770 N. Frontage Road


Copyright 2002 Printed in U.S.A. Skokie, Illinois 60077
EA9 Rigid Conduit Fittings EA9
90° Bushed & 90° Corner Pull-in Conduit Elbows
Threaded For Rigid Conduit & IMC

Type 9 Insulated
Throat
Features: Trade Size Catalog Catalog Dimensions in Inches
(inches) Number Number A B C
• Available with insulated throat
• Threaded for rigid conduit, Female NPT 1
/2 9-50 9-50T 17/8 17/8 11
/16
Male NPS 3
/4 9-75 9-75T 215/16 23/16 3
/4
• Telephone elbow, floor outlet fittings 1 9-100 9-100T 21/2 21/2 13
/16
11/4 9-125 9-125T 3 3 7
/8
Material/Finish:
Malleable Iron/Zinc Electroplated

Optional Finish:
Mechanically Galvanized.
Type 9
Contact your local representative for pricing
and availability.

Third Party Certification:


UL Listed: E-11853 and 11857

CSA Certified: 9795

Applicable Third Party Standards:


UL Standard: 514
CSA Standard: C22.2 No. 18
Fed. Spec: W-F-408E
NEMA: FB-1

Type CE Trade Size Catalog Dimensions in Inches


(inches) Number A B
Material/Finish:
Malleable Iron/Zinc Electroplated 1
/2 CE-050 21/2 2
3
/4 CE-075 23/4 21/8
1 CE-0100 31/4 23/8
Third Party Certification:
UL Listed: E-11853

Applicable Third Party Standards:


UL Standard: 514B
NEMA: FB-1

Type CE

Effective February, 2002 7770 N. Frontage Road


Copyright 2002 Printed in U.S.A. Skokie, Illinois 60077
EA10 Rigid Conduit Fittings EA10
Offset Nipples
Threaded For Rigid Conduit

Type ON Insulated Dimensions in Inches


Rigid conduit threading. Throat Thread
Trade Size Catalog Catalog Body Length Type
(inches) Number Number Length Each End Thread
Use:
Provides box-to-box connection of knock- 1
/2 ON-50 ON-50T 111/16 1
/2 NPS
outs. Allows misaligned knockout connec- 3
/4 ON-75 ON-75T 15/8 1
/2 NPT
tion by “rolling” the offset nipple until aligned 1 ON-100 ON-100T 15/8 9
/16 NPT
with each knockout.
11/4 ON-125 ON-125T 15/8 11
/16 NPT
11/2 ON-150 ON-150T 11/2 3
/4 NPT
Feature: 2 ON-200 ON-200T 11/2 13
/16 NPT
Type ON
• Available with insulated throat.

Material/Finish:
Malleable Iron/Zinc Plated

Optional Finish:
Mechanically Galvanized.
Contact your local representative for pricing
and availability.

Third Party Certification:


UL Listed: E-11853

CSA Certified: 9797

Applicable Third Party Standards:


UL Standard: 514B
CSA Standard: C22.2 No. 18
Fed. Spec: W-F-408E
NEMA: FB-1

Effective February, 2002 7770 N. Frontage Road


Copyright 2002 Printed in U.S.A. Skokie, Illinois 60077
EA11 Rigid Conduit Fittings EA11
90° Raintight Corner Pulling Ells
Threaded For Rigid Conduit & IMC

Type FF Trade Size Catalog Dimensions in Inches


90° Female/Female (inches) Number A B

1
/2 FF-050 17/8 17/16
Use: 3
/4 FF-075 21/4 19/16
Provides a compact wire-pulling point and a 1 FF-100 23/4 115/16
90° change of direction in a conduit run. 11/4 FF-125 31/4 25/16

11/2 FF-150 33/4 29/16


Features: 2 FF-200 45/8 31/4
• Threaded for rigid conduit and IMC (NPT) 21/2 FF-250 51/2 311/16
• Furnished with Neoprene gasketed steel 3 FF-300 61/2 315/16
Type FF
cover, zinc electroplated.
• Raintight

Material/Finish:
Malleable Iron/Zinc Plated

Third Party Certification:


UL Listed: E-11853

CSA Certified: 9795

Applicable Third Party Standards:


UL Standard: 514B
CSA Standard: C22.2 No. 18
NEMA: FB-1

Type MF Insulated
90° Male/Female Throat
Trade Size Catalog Catalog Dimensions in Inches
(inches) Number Number A B C
Use:
For connecting rigid conduit or IMC to box /2
1
MF-050 MF-050T 17/8 13/8 /16
7

or enclosures. /4
3
MF-075 MF-075T 21/4 11/2 /2
1

1 MF-100 MF-100T 23/4 13/4 /16


9

Features:
11/4 MF-125 MF-125T 31/4 21/8 11
/16
• Threaded for rigid conduit and IMC 11/2 MF-150 MF-150T 33/4 211/16 11
/16
Female NPT, Male NPSM 2 MF-200 MF-200T 45/8 213/16 13
/16
• Furnished with neoprene gasketed, steel Type MF
cover, zinc plated. 21/2 MF-250 MF-250T 51/2 33/4 /16
15

3 MF-300 MF-300T 61/2 315/16 11/8


• Furnished with locknut.
• Raintight
• Available with insulated throat

Material/Finish:
Malleable Iron/Zinc Electroplated

Third Party Certification:


UL Listed: E-11853

CSA Certified: 9795

Applicable Third Party Standards:


UL Standard: 514B
CSA Standard: C22.2 No. 18
NEMA: FB-1

Effective February, 2002 7770 N. Frontage Road


Copyright 2002 Printed in U.S.A. Skokie, Illinois 60077
EA19 Rigid Conduit Fittings EA19
Combination Couplings
For Rigid Conduit, IMC & EMT

Type ETR Trade Size Catalog Dimensions in Inches


(inches) Number Length Max Dia.
Features:
• Threaded rigid and IMC to compression EMT /2
1
ETR-50 13/8 11/8
• Concretetight /4
3
ETR-75 15/16 13/8
• NPT female hub 1 ETR-100 11/2 13/4
11/4 ETR-125 17/8 23/8
Material/Finish: 11/2 ETR-150 17/8 21/2
Malleable Iron/Zinc Plated 2 ETR-200 25/16 3

Third Party Certification: Type ETR


UL Listed: E-11853

Applicable Third Party Standards:


UL Standard: 514B
Fed. Spec: W-F-408E

Type CB Dimensions in Inches


Trade Size Catalog Flex.
Features: (inches) Number Length Max Dia. Range
• Threaded rigid and IMC to flexible metal
• Rigid hub
1
/2 CB-50 11/2 11/4 /32 - 15/16
25

3
/4 CB-75 13/4 11/2 /32 - 15/64
29

• NPT threads 1 CB-100 17/8 17/8 19/32 - 17/16

Material/Finish:
Malleable Iron, Zinc Plated

Third Party Certification: Type CB


UL Listed: E-11853

CSA Certified: 9795

Applicable Third Party Standards:


UL Standard: 514B
CSA Standard: C22.2 No. 18
Fed. Spec: W-F-408E

Type ESR Trade Size Catalog Dimensions in Inches


(inches) Number A B C
Features:
• Concretetight /2
1
ESR-50 111/16 15
/16 11/4
• Set screw /4
3
ESR-75 21/16 11/8 11/2
1 ESR-100 21/2 1 /8
3
113/16
• Threadless rigid and IMC to EMT

Material/Finish:
Malleable Iron/Zinc Plated

Third Party Certification: Type ESR


UL Listed: E-11853

Applicable Third Party Standards:


UL Standard: 514B
Fed. Spec: W-F-408E

Effective February, 2002 7770 N. Frontage Road


Copyright 2002 Printed in U.S.A. Skokie, Illinois 60077
EA20 Rigid Conduit Fittings EA20
Concrete Slab Electroform Inserts
For Threaded Rigid Conduit & IMC

Type EF & Type EFL


Use:
For conduit installed in poured concrete slabs.

Nail, screw or tack-weld insert to concrete


deck form.

Features:
• Inserts available in straight or 90°

Material/Finish:
Malleable Iron/Zinc Plated
Type EF-50 — Type EF-100 Type EFL-50 — Type EFL-100
Third Party Certification:
For concrete slab 4” thick and up. For slabs 6” thick and up require
UL Listed: E-11853
bend conduit sweep.

CSA Certified: 9795


STRAIGHT CONDUIT INSERTS
Applicable Third Party Standards:
Dimensions in Inches
UL Standard: 514B
Base
CSA Standard: C22.2 No. 18 Trade Size Catalog Base Across
Fed. Spec: W-F-408E (inches) Number Dia. Flats Height

/2
1
EF-50 115/16 13/4 15/16
/4
3
EF-75 23/16 2 13/8
1 EF-100 21/2 35/16 15/8

90° CONDUIT INSERTS


Dimensions in Inches
Base to
Trade Size Catalog Base Turning Conduit
(inches) Number Dia. Radius Center Height

1
/2 EFL-50 115/16 33/4 31/8 35/8
3
/4 EFL-75 23/16 313/16 31/16 311/16
1 EFL-100 21/2 313/16 215/16 311/16

Shown in poured concrete slabs before wood or steel forms are removed.

Effective February, 2002 7770 N. Frontage Road


Copyright 2002 Printed in U.S.A. Skokie, Illinois 60077

S-ar putea să vă placă și