Data can travel in both directions at the same time is called a_______________.

UARTs are generally capable of _____________________ data at the same time.


UARTs are generally contain ________________status register(s) and control register.
RS-232 driver must be able to produce between ____________.
RS-485 interface maximum cable length of ______________feet.
RS-485 data signal rate up to _____________Mbps.
RS-485 capbble of suporting a multi____________configration.
A bit in the UARRT's __________ register can be monitored to determine when a byte has been rece
RS-485 capbble of suporting up to ________nodes.
UART by writing and reading from________locations
The__________ handler read the byte from the port, Which generally clears the interrupt source.
A special type of buffer called a_______buffer is often used to capture data a serial port.
RS-232 standard doesn't specify which line to use when you are not interfacing to a _______
Which pin in RS232 is used for DSR of DTE____________.
RS232 standard was developed by _____________.
Methode of monitoring the UART status is called____________.
A special type of buffer used for capturing the the data on serial port is called as _________.
Interrupt vector of COM2 in a PC is __________.
Maximum baud rate supported by RS232 port of a PC is ______________.
COM1 is connected with interrupt ________.
Each ring buffer will consists of _______ elements.
Storage of data is an array of __________.
Which of the following is a signal used for flow control?
The communication standard that uses differential bus mode is __________.
Each communicating elementon a RS485 interface is __________.
RS232 standard requires __________ interface.
The load capacitance on a RS232 driveris not to exceed ___________ pF.
The load resistance on a RS232 driver must be between _____ and ______ ohms.
The start bit in an asynchronous communication is ______________.
Number of stop bit(s) in an asynchrounous communication is __________.
Simplex Half duplex Full duplex Semi duplex Full duplex
senting Receiving Senting or Receiving
senting and receiving
senting and receiving
One two Three One or more One or more
+5 to +15 and -5+5
to -15
to +10 and +1
-5 to
to-10
+5 and -1 +0
to -5
to +15 and +5
-0 to
to-15
+15 and -5 to -15
1000 2000 3000 4000 4000
10 20 30 40 10
Master slave Master as well slave
Master and slaveMaster
Control Status Status and control
Holding Status
32 64 128 256 32
Memory I/O Port Memory or I/O port
RAM Memory or I/O port
Interrupts Status Control Status and control
Interrupts
Star Circular Ring Ring or CircularRing or Circular
Modem Printer Display I/O device Modem
5 6 7 8 6
IEEE EIA FCC ISO EIA
Polling Scanning Testing Masking Polling
Module buffer Circular buffer Rectangular buffer
Local buffer Circular buffer
0x0F 0x0E 0x0C 0x0B 0x0B
115200 bps 38400 bps 57600 bps 15600 bps 115200 bps
IRQ 7 IRQ 6 IRQ 4 IRQ 3 IRQ 4
One Two Three Four Four
INT8Us INT16Us INT8S INT16S INT8Us
TXD CTS RXD GND CTS
RS232 I2C RS485 UART RS485
DTE DCE Communcation device
Node Node
Party-line Point-to-point Multi-drop Common-line Point-to-point
2500 1000 100 250 2500
2000, 5000 3000, 7000 200, 500 300, 700 3000, 7000
MARK SPACE MARK to SPACE SPACE to MARKSPACE
One Two Half One or Two One or Two
and receiving

15 and -5 to -15

or I/O port