Read this guide before installing and using the Do not install the appliance at a distance of
appliance. less than 50 cm from inflammable substances
(alcohol, etc.) Or from pressurised containers
During the installation of the indoor and outd- (e.g. spray cans).
oor units the access to the working area should
be forbidden to children. If the appliance is used in areas without the
Unforeseeable accidents could happen. possibility of ventilation, precautions must be
taken to prevent any leakage of refrigerant gas
Make sure that the base of the outdoor unit is from remaining in the environment and creat-
firmly fixed. ing a danger of fire
Check that air should not enter the refrigerant
system and check for refrigerant leaks when The packaging materials are recyclable and
moving the air conditioner. should be disposed of in the separate waste
bins .Take the air conditioner at the end of its
Carry out a test cycle after installing the air co- useful life to a special waste collection centre
nditioner and record the operating data. for disposal.
The ratings of the fuse installed in the built in- Only use the air conditioner as instructed in
control unit are T 5A / 250V . this booklet . These instructions are not inten-
ded to cover every possible condition and
The user must protect the indoor unit with a situation . As with any electrical household
fuse of suitable capacity for the maximum in- appliance , common sense and caution are
put current or with another overload protection therefore always recommended for installat-
device. ion, operation andmaintenance.
Ensure that the mains voltage corresponds to
that stamped on the rating plate . Keep the sw- The appliance must be installed in accordance
itch or power plug clean. Insert the power plug with applicable national regulations.
correctly and firmly into the socket, thereby a-
voiding the risk of electric shock or fire due to Before accessing the terminals , all the power
insufficient contact. circuits must be disconnected from the power
supply.
Check that the socket is suitable for the plug ,
otherwise have the socket changed.
The appliance shall be installed in accord-
ance with national wiring regulations.
The appliance must be fitted with means for
disconnection from the supply mains having The air conditioner must be installed by
a contact separation in all poles that provide professional or qualified persons.
full disconnection under overvoltage
category III conditions, and these means
must be incorporated in the fixed wiring in
accordance with the wiring rules.
1
SAFETY RULES AND RECOMMENDATIONS FOR THE USER
Do not try to install the conditioner alone; Never remain directly exposed to the flow of
always contact IFB authorized service personnel. cold air for a long time. The direct and prolo-
nged exposition to cold air could be dangero-
Cleaning and maintenance must be carried out us for your health .Particular care should be
by specialised IFB service personnel. In any taken in the rooms where there are children ,
case disconnect the appliance from the mains old or sick people.
electricity supply before carrying out any
cleaning or maintenance. If the appliance gives off smoke or there is a
smell of burning, immediately cut off the pow-
Ensure that the mains voltage corresponds to er supply and contact the Service Centre.
that stamped on the rating plate. Keep the swi-
tch or power plug clean. Insert the power plug The prolonged use of the device in such
correctly and firmly into the socket , thereby conditions could cause fire or electrocution.
avoiding the risk of electric shock or fire due
to insufficient contact. Have repairs carried out only by an authoris-
ed Service Centre of IFB. Incorrect repair
Do not pull out the plug to switch off the app- could expose the user to the risk of electric
liance when it is in operation, since this could shock, etc.
create a spark and cause fire, etc.
This appliance has been made for air conditi- Unhook the automatic switch if you foresee
oning domestic environments and must not be not to use the device for a long time.
used for any other purpose , such as for drying The airflow direction must be properly adjus-
clothes, cooling food, etc. ted.
The packaging materials are recyclable and
should be disposed off in the separate waste The flaps must be directed downwards in
bins . Take the air conditioner at the end of its the heating mode and upwards in the cooling
useful life to a special waste collection centre mode.
for disposal.
Always use the appliance with the air filter Only use the air conditioner as instructed in
mounted . The use of the conditioner without this booklet.These instructions are not intend-
air filter could cause an excessive accumulation ed to cover every possible condition and situ-
of dust or waste on the inner parts of the device ation.As with any electrical household applia-
with possible subsequent failures. nce, common sense and caution are therefore
always recommended for installation , operat-
The user is responsible for having the appliance ion and maintenance.
installed by an IFB authorized service personnel
who must check that it is earthed in accordance Ensure that the appliance is disconnected from
with current legislation and insert a thermomag- the power supply when it will remain inoperat-
netic circuit breaker. ive for a long period and before carrying out
any cleaning or maintenance.
The batteries in remote controller must be
recycled or disposed off properly.
Disposal of Scrap Batteries --- Please disca- Selecting the most suitable temperature can pr-
rd the batteries as sorted municipal waste at event damage to the appliance.
the accessible collection point.
2
SAFETY RULES AND PROHIBITIONS
Do not bend , tug or compress the power cord Do not leave windows or doors open for long
since this could damage it. Electrical shocks or when the air conditioner is operating.
fire are probably due to a damaged power cord.
IFB Authorised technical personnel only must
replace a damaged power cord. Do not direct the airflow onto plants or anim-
als.
Do not use extensions or gang modules.
A long direct exposition to the flow of cold
air of the conditioner could have negative
Do not touch the appliance when barefoot or effects on plants and animals.
parts of the body are wet or damp.
Do not put the conditioner in contact with
water.
Do not obstruct the air inlet or outlet of the in- The electrical insulation could be damaged
door or the outdoor unit. and thus causing electrocution.
The obstruction of these openings causes a re-
duction in the operative efficiency of the con- Do not climb onto or place any objects on the
ditioner with possible consequent failures or indoor unit and outdoor unit.
damages.
Never insert a stick or similar object into the
In no way alter the characteristics of the appli- appliance. It can cause injury.
ance.
Children should be supervised to ensure
Do not install the appliance in environment that they do not play with the appliance.
where the air contains gas, oil, sulphur or If the supply cord is damaged, it must be
near sources of heat. replaced by an authorized IFB service
personnel to avoid any damage or cause.
3
NAMES OF THE PARTS
INDOOR UNIT
No. Description 1 2-3 4-5
1 Front panel
2 Air filter
3 Optional filter (if installed)
6
4 LED Display
5 Signal receiver
6 Terminal block cover
11 10 9 8 7
7 Ionizer generator(if installed)
8 Deflectors
9 Emergency button
Tim
er
Sup On
er Off
Mo
de
OUTDOOR UNIT 13
No. Description
13 Air outlet grille
14 Outdoor unit rating label
15 Cover
16 gas valve
14
17 liquid valve
15
16
WALL AIR-CONDITIONER
The conditioner is made up of two or more units
connected between themselves through copper
17
pipes (properly insulated) and an electrical con-
necting cable.
The indoor unit is installed on the walls of the
room to be conditioned.
The outdoor unit is installed on the floor or on the
wall on suitable brackets.
Technical data of the air conditioner are printed on Note: the above figures are only intended to be a
the labels placed on the indoor and outdoor units. simple diagram of the appliance and may not
The remote control has been designed for an easy correspond to the appearance of the units that
and fast use. have been purchased.
4
INDOOR UNIT DISPLAY
1 2 3 4 5 /O
1
5
2
4
2 5 3 6 7
3
1
2
3
4
5
1 5
2 3 4
The shape and position of switches and indicators may vary according to the model, but their function
is the same.
5
EMERGENCY FUNCTION & AUTO-RESTART FUNCTION
AUTO-RESTART FUNCTION
The appliance is preset auto - restart function
with this function the air conditioner can keep the
ON / OFF
selected settings after a blackout or a voltage drop. POWER SLEE
P TIMER RUN
EMERGENCY FUNCTION
Emergency
If the remote control is lost, proceed as follows: button
Lift the unit s front panel to reach the emergency
button of the air conditioner front panel
1. If you press the button once ( one beep ), the air
conditioner will work in forced cooling function; ON/OFF
Remark: the external static pressure of heat pumps is 0 Pa for all models.
6
REMOTE CONTROL
Off 7
Sleep
11 Dry
Fan 10
3 ON/OFF To switch the conditioner on and off. 4
Fan
Heat
Swing
6 SLEEP 2
To activate the function SLEEP
In cooling mode,press this button ,the temperature
will increase 2 on the base of setting temperature
In heating mode, press this button, the temperature
7 ECO/ will decrease 2 on the base of setting temperature
For one press is ECO function, For long press for 2
seconds, is ANTI-MILDEW.
1
3 2
8 MODE To select the mode of operation 7
8 MODE ECO TIMER
5
In cooling mode, press this button, the unit will give 4 FAN SLEEP DISPLAY
12
the maximum cooling temperature with 16 6
10 SWING SWING
10
9 SUPER/TURBO In heating mode, press this button, the unit will give
11 HEALTHY TURBO
9
the maximum heating temperature with 31
The outlooking and some function of remote control may vary according
to the model.
The shape and position of buttons and indicators may vary according to
the model, but their function is the same.
The unit confirms the correct reception of each press button with a beep.
7
REMOTE CONTROL
Remote control DISPLAY
Meaning of symbols on the liquid crystal display
Cool
3 DEHUMIDIFYING indicator Health Swing
Dry
5 HEATING indicator
Mode
OFF
7 or or TIMER OFF indicator
TIMER
ON
8 or TIMER or TIMER ON indicator
AUTO or
9 or or (FLASH) AUTO FAN indicator
or
10 or LOW FAN SPEED indicator
or
15 or
SUPER indicator
POWERFUL
ON
16 or HEALTHY indicator
HEALTHY
8
REMOTE CONTROL
Preliminary Instructions
How to insert the batteries
Remove the cover from the battery compartment , by sliding it in the
direction of the arrow
Insert the new batteries, ensuring that the (+) and (-) directions are
correct +
control or if you change them, you need to program the remote Super
Off
Sleep Super
Off
Sleep
Feel Feel
control of only cooling or heat pump air conditioners. Cool Cool
Health Swing Health Swing
This is very easy:as soon as you insert the batteries, the symbols Dry Dry
Heat
Swing Fan Fan
Heat
Swing
r Off
Healt Eco/
Feel
receptor
h
Cool Sleep
Fan
Dry
Swin
Fan
g
Heat
Swin
g
3. Never leave the remote control exposed to the rays of the sun.
Mo
de
9
MODES OF OPERATION
The conditioner is designed to create the comfortable
climatic conditions for the people in the room.
It can cool and dehumidify (and heat in models with Filter
heat pump) the air in a completely automatic way.
The air sucked by the fan enters from the grill of the Heat
Exchanger
front panel and passes through the filter, which keeps
the dust.Then it is conveyed the heat exchanger and
cooled and dehumidified or heated through the heat
exchanger.
The heat removed from the room is drained outside.
When the cycle has finished the fan gives back the
fresh air in the room;the direction of the air outlet is
regulated by the flaps , which are motorized up and
down,and manually moved right and left by the verti- Fan
cal deflectors
CAUTION!
Never position Flaps manually, the delicate mech-
anism activating them could be seriously damaged!
DANGER!
Never insert your hand or objects in the air outlet of
the units!These units contains a fan that turns at high
speed.
flap
movement Deflectors
flaps
10
MODES OF OPERATION
COOLING MODE
HEATING MODE
Off
11
MODES OF OPERATION
TIMER MODE----TIMER ON
ON/OFF
1
To set the automatic switching-on of MODE TIMER ANTI-MILDEW
TIMER the air conditioner 2
Timer Eco/
On FAN SPEED SUPER ECO
Off
3
To program the time start,the appliance should be off. Super Feel Sleep
SWING SLEEP HEALTHY
Cool
Press TIMER , Set the temperature with pressing the Health
Dry
Swing
key + or ,Press TIMER Again , set the time with Fan Fan Swing
pressing the key + or , Press the key more times till Heat
on the display you can read the time which passes between
the programming and the timed start.
Mode
IMPORTANT!
Before proceeding with the timed start : program the
working mode with the key MODE and the
fan speed with the key FAN . Switch the con-
ditioner off (with the key ON/OFF ).
Note:To cancel the setted function ,press the TIMER POWER SLEEP TIMER RUN
SWING
button again.
Indoor display
Note:In case of power off,it is necessary to set TIMER
ON again
SWING
POWER SLEEP TIMER RUN
Note: While the time was right settled, the Indoor display
TIMER function of this remote(clock
function) can set by half hours
12
MODES OF OPERATION
FAN MODE
ON/OFF
1
Sleep
3
Super Feel
SWING SLEEP HEALTHY
To set the DRY mode , Press MODE untill Cool
Swing
Health
( DRY ) appears in the display . An automatic Dry
function of alternating cooling cycles and air fan Fan Fan Swing
Heat
is activated.
Mode
13
MODES OF OPERATION
FEEL MODE
ON/OFF
1
Automatic mode. MODE TIMER ANTI-MILDEW
FEEL 2
Timer Eco/
On FAN SPEED SUPER ECO
Off
3
Super Feel Sleep
To activate the FEEL (automatic) mode of operation, Cool
SWING SLEEP HEALTHY
Heat
SLEEP MODE
ON/OFF
1
Heat
The function SLEEP automatically adjusts the
temperature to make the room more comfortable
during the night sleep . In cooling or dry mode , the Mode
set temperature will automatically raise by1 every
60 minutes, to achieve a total rise of 2 during the
first 2 hours of work.
In heating mode the set temperature is gradually
decreased by 2 during the first 2 hours of work.
After 10 hours running in sleep mode the air conditio- SLEEP FAN
Indoor display
14
PROTECTION
The protective device maybe trip and stop the appliance in the cases listed below.
For T1 Climate condition models:
No. MODEL
Outdoor air temperature is over 24
1 Heating Outdoor air temperature is below -7
Room temperature is over 27
Outdoor air temperature is over 43
2 Cooling
Room temperature is below 21
No. MODEL
Outdoor air temperature is over 24
1 Heating Outdoor air temperature is below -7
Room temperature is over 27
Outdoor air temperature is over 52
2 Cooling
Room temperature is below 21
After stopping and restarting the air coditioner or after changing the mode during operation, the
system does not restart immediately, Untill after 3 minutes(protection function for the compressor)
15
INSTALLATION MANUAL---Selecting the Installation Place
INDOOR UNIT
Install the indoor unit level on a strong wall that is not Mounting plate
150
subject to vibrations.
The inlet and outlet ports should not be obstructed:the 150
air should be able to blow all over the room.
Do not install the unit near a source of heat , steam,or 150
flammable gas.
Install the unit near an electric socket or private circuit.
Do not install the unit where it will be exposed to condensed water drain pipe
direct sunlight. Sleeve
Install the unit where connection between indoor and insulating covering
outdoor unit is as easy as possible.
Install the unit where it is easy to drain the condensed electrical cable
water.
water drain pipe
Check the machine operation regularly and leave the
necessary spaces as shown in the picture.
Install the indoor unit where the filter can be easily
accessible.
500
Do not install the unit where people often pass.Select
a place where the air discharge and operating sound
level will not disturb the neighbours.
Avoid installing the unit where it will be exposed
to direct sunlight ( other wise use a protection , if
necessary, that should not interfere with the air flow).
300
Leave the spaces as shown in the picture for the air to
circulate freely. 300
Install the outdoor unit in a safe and solid place.
If the outdoor unit is subject to vibration, place rubber
gaskets onto the feet of the unit..
200 500
Installation Diagram 0
be less than 5m
Indoor unit
Height should
Outdoor unit
Only persons and/or companies qualified and experienced in the installation,service and repair of refrigerant
products should be permitted to do so.The purchaser must ensure that the person and/or company who is to
install,service or repair this air conditioner has qualifications and experience in refrigerant products.
16
INSTALLATION MANUAL---Installation of the Indoor unit
Before starting installation, decide on the position of the
indoor and outdoor units, taking into account the minim-
um space required around the units
Install the indoor unit in the room to be air conditio-
ned, avoiding to install in corridors or communal
areas.
Install the indoor unit at a height of at least 2.5 m
from the ground.
To install, proceed as follows: 50
17
INSTALLATION MANUAL---Installation of the Indoor unit
NO NO
18
INSTALLATION MANUAL---Installation of the Indoor unit
INSTALLATION OF THE INDOOR UNIT
After having connected the pipe according to the instruc- Covered by vinyl tape
tions, install the connection cables. Now install the drain refrigerant insulation
pipe. After connection,lag the pipe, cables and drain pipe pipe sleeve
connection
with the insulating material. cable
refrigerant
1. Arrange the pipes ,cables and drain hose well. connection pipe
2. Lag the pipe joints with insulating material , securing cable 1
(for heat-pump)
it with vinyl tape. Probe Condensed water
3. Run the bound pipe , Cables and drain pipe through cable(for heat-pump) drain pipe
the wall hole and mount the indoor unit onto the upper mounting plate
part of the mounting plate securely.
4. Press and push the lower part of the indoor unit tightly
against the mounting plate
19
INSTALLATION MANUAL---Installation of the outdoor unit
ELECTRICAL CONNECTIONS
wiring diagram on the
1. Remove the cover. back of the cover
2. Connect the cable wires to the terminal board using
the same numbering as in the indoor unit.
3. For the electrical connections, see the wiring diagram
on the back of the cover
4. Fasten the cables with a cable-clamp. screw
5. An efficient earth connection must be ensured.
6. Replace the covers . remove
the upper
cover
outdoor unit
connection pipes
20
INSTALLATION MANUAL---Installation of the outdoor unit
BLEEDING
3-way valve diagram
The air and humidity left inside the refrigerant circulat-
ion can cause compressor malfunction. After having co- connect to indoor unit
nnected the indoor and outdoor units, bleed the air and
humidity from the refrigerant circulation using a va- open position
cuum pump. spindle
(1) Unscrew and remove the caps from the 2 - way and
3-way valves.
(2) Unscrew and remove the cap from the service port. Connect to
needle
(3) Connect the vacuum pump hose to the service port. outdoor unit
(4) Open the 2 - way valve by 1/4 turn and then close it Valve core
service port cap
after10 seconds. Check all the joints for leaks using
liquid soap or an electronic leak device.
(5) Operate the vacuum pump for 10 - 15 minutes until
Indoor unit
an absolute vacuum of 10 mm Hg has been reached.
(6) With the vacuum pump still in operation , close the Refrigerant flow direction 2-way valve
(8) Replace and tighten all the caps on the valves. port nut
(1) Turn
(1) Turn
(8) Tighten
(2) Turn Valve cap (8) Tighten
(8) Tighten
21
INSTALLATION MANUAL---Information for the installer
FIXED-SPEED TYPE
MODEL capacity (Btu/h) 5k 7k 9k 12k 15/18k 22/24k 28/30k
1/4 1/4 1/4 1/4 1/4 3/8 3/8
Liquid pipe diameter
( 6) ( 6) ( 6) ( 6) ( 6) ( 9.52) ( 9.52)
3/8 3/8 3/8 1/2 1/2 5/8 5/8
Gas pipe diameter
( 9.52) ( 9.52) ( 9.52) ( 12) ( 12) ( 15.88) ( 15.88)
Lenght of pipe with standard charge 3m 3m 3m 3m 4m 4m 4m
Maximum distance between indoor and outdoor unit 15m 15m 15m 15m 15m 15m 15m
Additional gas charge 20g/m 20g/m 20g/m 20g/m 30g/m 30g/m 30g/m
FIXED-SPEED TYPE
7k 9k 12k 15/18k 22/24k 28/30k
MODEL capacity (Btu/h)
1/4 1/4 1/4 1/4 3/8 3/8
Liquid pipe diameter
( 6) ( 6) ( 6) ( 6) ( 9.52) ( 9.52)
3/8 3/8 3/8 1/2 5/8 5/8
Gas pipe diameter
( 9.52) ( 9.52) ( 9.52) ( 12) ( 15.88) ( 15.88)
Lenght of pipe with standard charge 3m 3m 3m 4m 4m 4m
Maximum distance between indoor and outdoor unit 15m 15m 15m 15m 15m 15m
INVERTER TYPE
9k 12k 15/18k 22/24k
MODEL capacity (Btu/h)
1/4 1/4 1/4 3/8
Liquid pipe diameter
( 6) ( 6) ( 6) ( 9.52)
3/8 1/2 1/2 5/8
Gas pipe diameter
( 9.52) ( 12) ( 12) ( 15.88)
Lenght of pipe with standard charge 3m 3m 4m 4m
Maximum distance between indoor and outdoor unit 15m 15m 15m 15m
22
INSTALLATION MANUAL---Information for the installer
WIRING DIAGRAM
FOR 5K-7K-9K-12K-18K COOLING ONLY MODELS FOR 22K-24K-28K-30K COOLING ONLY MODELS
(FOR 9K-12K-18K-24K COOLING ONLY MODELS TO
INDOOR UNIT NORTH AMERICAN MARKET)
INDOOR UNIT
POWER
SUPPLY OUTDOOR UNIT
OUTDOOR UNIT
POWER
SUPPLY
FOR 7K-9K-12K-18K HEAT PUMP MODELS FOR 22K-24K-28K-30K HEAT PUMP MODELS
(FOR 9K-12K-18K-24K HEAT PUMP MODELS TO
NORTH AMERICAN MARKET)
INDOOR UNIT
INDOOR UNIT
POWER
SUPPLY
OUTDOOR UNIT POWER OUTDOOR UNIT
SUPPLY
POWER
SUPPLY OUTDOOR UNIT OUTDOOR UNIT
POWER
SUPPLY
23
INSTALLATION MANUAL---Information for the installer
2 2 2 2 2 2 2
2 0.75mm 0.75mm 0.75mm 0.75mm 0.75mm 0.75mm 0.75mm
Type for 220V of fuse used on indoor unit controller for 7K , 9K , 12K 15K , 16K , 18K , 22K , 24K , 30K is
50T with rating 3.15 A , 250V Type for 110V of fuse used on indoor unit controller for 7K , 9K 12k is 50T with
rating 3.15 A , 125V, ; Type of fuse used on inverter outdoor unit controller for 7K , 9K , 12K is 61T with rating
15 A , 250V , for 18K , 22K , 24K is 65TS with rating 25A , 250V.
24
MAINTENANCE
INDOOR UNIT
ANTIDUST FILTERS
1. Open the front panel following the direction of the
arrow
2. Keeping the front panel raised with one hand, take out
the air filter with the other hand
3. Clean the filter with water ; if the filter is soiled with
oil,it can be washed with warm water (not exceeding
45 ).
Leave to dry in a cool and dry place.
4. Keeping the front panel raised with one hand , insert
the air filter with the other hand antidust filter
5. Close
25
TROUBLESHOOTING
26
FAST COOL Air Conditioner
---For Select Models
Service conditions
1. Please install "Fast Cool air Conditioner "software in your mobile first.
2. "Fast Cool air Conditioner" software is compatible with 2.1 android or above version.
3. "Fast Cool air Conditioner " software is compatible with 5.0 IOS or above version.
4. This operation interface can be used on all Air conditioners, but some of the Air
conditioners are not equipped with all functions shown on the interface.
Please refer to the actual operation function of the air conditioner that you bought.
27
Air conditioner configuration
3.MAC address
28
Control the air conditioner
WiFi reset
Method 1
1.Take out the front panel of the air conditioner
Open the air conditioner's front panel and locate the WIFI module.
2.WiFi reset of the air conditioner
Use the suitable tool to press WIFI module "Reset" button, until
light continues flashing
Method 2
Press "display" button on the remote controller for 6 times within
20 seconds until buzzing is heard.
29
Trouble shooting
Software display:
Air conditioner out of line. Please check network working
1. The air conditioner has been reconfigurated;
2. Air conditioner out of power;
Mobile can't find air 3. Router out of power;
conditioner 4. The air conditioner cannot connect to the router;
5. The air conditioner cannot connect to network through the router
(under the remote mode);
6. Mobile can't connect to router (Under local control mode);
7. The mobile phone cannot connect to network (under the remote mode).
The air conditioner The air conditioner can't be deleted under locked state, please unlock it
can't be deleted in and try again.