S. NO.

KPI THRESHOLD
1 TASR >=99
2 RASR >=98
3 SD BLOCKING <=0.5
4 SD DROP <=2
5 TCH BLOCKING <=1
6 TCH DROP <=2
7 HOFR <=5
8 DL QUAL >=97
9 UL QUAL >=97
IFTASR IS POOR THEN CHECK THE FOLLOWING PARAMETER
TASR TRAFFIC CHANNEL ASSIGNMENT SUCCESS RATE
1 CHECK HARDWARE CONNECTION (208)
2 CHECK INTERFERENCE .(190,196)
3 CHECK PATH BALANCE.(208)
4 CHECK VSWR.(208)
IF SDCCH BLOCKING OCCURS ABOVE THE THRESHOLD THEN CHECK THE FOLLOWING
SDCCH BLOCKING SIGNALLING DEDICATED CONTROL CHANNEL
1 CHECK UTILISATION (IF IT IS GREATER THAN 100 %)
2 CHECK HOW MANY SD BLOCKS USING IN PEAK HOUR FOR 3 CONTINUOUS DAYS.
4 INCREASE SD BLOCKS ON THE EXISTING TRX, IF TCH CONG OR BLOCKING IS NOT THERE.
5 OTERWISE ADD TRX THEN ADD SDCCH BLOCKS AS PER THE REQUIREMENT
6 CHANGE ALL TCHF INTO TCHD.
7 INCREASE FRL & FRU AS PER THE BLOCKING.
8 PUT SDCCH AT THE PROPER TIMESLOT.
9 CHECK ALARMS 7712,7743,7745.
10 CHECK THE LAC BOUNDARY
IF SDCCH DROP IS HIGH MEANS GREATER THAN GIVEN THRESHOLD CHECK THE FOLLOWING TERMS
SDCCH DROP
1
2
3
4
5
6
7
8
9
10
IF SDCCH DROP IS HIGH MEANS GREATER THAN GIVEN THRESHOLD CHECK THE FOLLOWING TERMS
SIGNALING & DEDICATED CONTROL CHANNEL DROP
CHECK ALARMS (7712,7743,7745.)
CHECK TASR, IF IT IS LOW CHECK HARDWARE(208,196,VSWR).
CHECK CO-BCCH & CO-BSIC HITTING EACH OTHER OR NEIGHBOUR.(76,153,196)
CHECK UL QUALITY,IF IT IS POOR PROPOSE TMA.
CHECK DL QUALITY IF IT IS POOR PROPOSE TMB.
CHECK DL & UL QUALITY BOTH IF IT IS POOR ,CHECK FREQUENCY & HOPPING PLAN, CHECK OVERSHOOTING.
CHECK OVERSHOOTING IF IT IS,CHECK BY 232 HOW MUCH SAMPLES ARE COMING B/W 0-3 KMTRS,CHECK RXP VALUE.
COVERAGE ISSUE(THERE WILL BE LAST COVERAGE OF THE SECTOR ITSELF)
CHECK TILT(MECHANICAL, ELECTRICAL & UPTILT).
CHECK THE CABLE SWAPING
IF TCH DROP IS HIGH MEANS GREATER THAN GIVEN THRESHOLD CHECK THE FOLLOWING STEPS.
TCH DROPS
1
2
3
4
5
6
7
8
9
10
IF TCH DROP IS HIGH MEANS GREATER THAN GIVEN THRESHOLD CHECK THE FOLLOWING STEPS.
TRAFFIC CHANNEL DROPS.
CHECK ALARMS,RELATED TO TRX,(7743,7745)
CHECK HARDWARE( POOR PATH LOSS),(208,196)
CHECK FREQUENCY & HOPPING PLAN(INTERFERENCE)(190,196)
CHECK NEIGHBOURS PROPERLY (TOTAL NEIGHBOURS & ONEWAY NEIGHBOUR)(61,74,ZEAP)
THEN CHECK ADJACENCY PARAMETER IN TARGET CELL(NCC,BCC,BCCH,LAC & SYNC),(60)
CHECK TRANSMISSION MEDIA(ABIS OR A INTERFACE)(2992,29993).
CHECK TCH DROP DUE TO TRANSCODER FAILURE(2955)
CHECK OVERSHOOTING WITH THE HELP OF 232.
CHECK TILT (MECHANICAL ELECTRICAL & UPTILT),CABLE SWAP.
CHECK NEIGHBOUR SITE STATUS(ND-23)
bcne
repeated cells
bcne action
IF TCH BLOCKING IS HIGH MEANS GREATER THAN GIVEN THRESHOLD CHECK THE FOLLOWING PARAMETERS
TCH BLOCKING:
1
2
3
4
5
6
7
8
9
IF TCH BLOCKING IS HIGH MEANS GREATER THAN GIVEN THRESHOLD CHECK THE FOLLOWING PARAMETERS
TRAFFIC CHANNEL BLOCKING
CHECK UTILISATION IF IT IS GREATER THAN 100%
CHECK HARDWARE STATUS(IF TRX IS LOCK,UNLOCK IT)
CHECK RTSL(IF IT IS NOT USED,USE IT,CHANGE ALL TCHF INTO TCHD).
CHECK IF SD BLOCKING OR SD CONG. IS NOT THEN REMOVE SD BLOCKS AS PER ANALYSIS.
STOP OVERSHOOTING(CHECK HT,UP TILT & RXP).
CHECK CELL LOAD BEARING IF POSSIBLE.
INCREASE FRL FRU AS PER THE BLOCKING(BUT SEE CALLS ARE TAKING FROM HOW MUCH DISTANCE).
ADD HARDWARE.(IF NOT POSSIBLE)
PROPOSE CAPACITY SITE(FOR UPLOADING THE SECTOR).
IF HANDOVER FAILURE RATE IS GREATER THAN THE GIVEN THRESHOLD CHECK FOLLOWING STEPS
HOFR
1
2
3
4
5
6
7
8
9
10
11
IF HANDOVER FAILURE RATE IS GREATER THAN THE GIVEN THRESHOLD CHECK FOLLOWING STEPS
HANDOVER FAILURE RATE
CHECK FREQUENCY & HOPPING PLAN(FOR INTERFERENCE). 60
CHECK THE HARDWARE OF THE TARGET CELL(IF FAULTY OR LOOSE CONNECTION,CHECK(208,196). 208,196
CHECK SYNC(IN SAME BCF & IN DIFFERENT BCF). 67
CHECK ADJACENCY PARAMETER OF SOURCE CELL IN TARGET CELL. 61
CHECK CO-BCCH & CO-BSIC NEIGHBOUR. 196
CHECK THE DAC VALUE OF THE BTS(7716).
CHECK ALARM IN TARGET CELL.
IF ALL THE THING IS PROPER EVEN HOFR COMING RECOMMEND TO REPLACE DUPLEXER.
CHECK IMPORTANT MISSING NEIGHBOUR(CHECK-ND-73) & ADD IT. 73
DELETE UN NECESSARY NEIGHBOUR (SEE ND-153). 153
CHECK OVERSHOOTING(ND-232). 232
IF DOWNLINK QUALITY IS LESS THAN THE GIVEN THRESHOLD THEN CHECK THE FOLLOWING STEPS
DL QUALITY
1
2
3
4
5
6
7
8
IF DOWNLINK QUALITY IS LESS THAN THE GIVEN THRESHOLD THEN CHECK THE FOLLOWING STEPS
DOWNLINK QUALITY
CHECK FREQUENCY & HOPPING PLAN(CHECK IF CO-BCCH & ADJ-BCCH OR BSIC) CHECK-196.
CHECK NEIGHBOUR IS DEFINED PROPERLY OR NOT.(CHECK ND-74).
CHECK OVER SHOOTING(ND-232).
CHECK SECTOR SWAP OR CABLE SWAPPING.
CHECK HARDWARE (208),TRX,DUPLEXER & ALL CONNECTOR & JUMPER.
CHECK VSWR.
PROPOSE TMB.
CHECK ALARMS IF ANY.
IF UPLINK QUALITY IS LESS THAN THE GIVEN THRESHOLD THEN CHECK THE FOLLOWING STEPS
UL QUALITY UPLINK QUALITY
1 CHECK FREQUENCY & HOPPING PLAN(CHECK IF CO-BCCH & ADJ-BCCH OR BSIC) CHECK-196.
2 CHECK NEIGHBOUR IS DEFINED PROPERLY OR NOT.(CHECK ND-74).
3 CHECK OVER SHOOTING(ND-232).
4 CHECK SECTOR SWAP OR CABLE SWAPPING.
5 CHECK HARDWARE (208),TRX,DUPLEXER & ALL CONNECTOR & JUMPER.
6 CHECK VSWR.
7 PROPOSE TMA.
8 CHECK ALARMS IF ANY.
REPORT-166:- SDCCH DROP RATIO PER CELL. THOGHTS
1 RF CALL % CHECK BCCH FREQUENCIES & BSIC ISSUES(190 & 196).
2 ABIS CALL % CHECK ALARMS 7725,7738 & 7760.
3 A If call(%) CHECK FROM SWITCH END.
4 T3101 EXPIRY
5 SDCCH GHOST Check TSC on TCH TRX.

DL Loss factors:
BS Power (dBm): KPI pwr_2 - Average BS power level (maximum powe
Combiner loss (dBm): Depends on the network. Given by the user for s
DL signal strength (dBm): KPI lev_1 - Average DL signal strength measu
DL Path Loss (dBm): Counted based on the factors above. (BS power - c
UL loss factors:
MS power (dBm): KPI pwr_1b - Average MS power level.
UL signal strength (dBm): KPI lev_2 - Average UL signal strength measu
UL path loss (dBm): Counted based on the factors above. (MS power -
Balance
DL-UL (dB): The difference between DL and UL path losses.
Delta: Difference between balances of TRXs having. The biggest and sm
er level (maximum power is 44.7 dBm)
rk. Given by the user for single TRX and multi TRX cases.
DL signal strength measured by MS.
ctors above. (BS power - combiner loss - DL signal strength

ower level.
UL signal strength measured by BTS.
tors above. (MS power - UL signal strength)

L path losses.