Sunteți pe pagina 1din 9

CONCORDIA UINVERSITY

DEPARTMENT OF BUILDING, CIVIL AND ENVIRONMENTAL


ENGINEERING

CIVI 212 “Civil Engineering Drawing”


Final Exam

Instructor: Dr. A.M. Hanna


Date: December 12, 2014
Time: 2.00 PM - 5.00 PM

General instructions:
Make every effort to draw to scale, neat and clear.
All questions are of equal value.
Assume any data missing.
----------------------------------------------------------------------------------------------------------------------------

1. Draw horizontal and vertical sections of the slab of the repeated floor of a high-rise building,
24x48m, supported on skeleton type structural system. The slab is made of 200 mm thick
supported on converted beams and columns 300x300mm, spaced at 6m center-to-center. Show
in both sections the supporting elements.

2. Draw a top view and across-section of a staircase (2 m wide) between two floors, made of 12
rises, 150 mm each. The goings are 250 mm each. Show the structural (supporting) elements.
The slab is supported on beams located on each floor and columns.

3. Draw horizontal section passing through a 5ft. window, in a wall made of wood studs 2x6in,
spaced at 16in. center-to-center, wool insulations, vapor barrier, 5/8 dry wall sheets. The
exterior will be covered by ¾ plywood sheet, and clay bricks.

4. Draw the front and side views of a steel column (W310x86) resting on a concrete pedestal
(510x750x600mm). Show the connections of the steel column and the concrete. The column is
connected to the base plate by two angles of 90mm (using 5 bolts) on the web and two angles
of 90mm (using 4 bolts) on the flanges. The base plate is 430x670x20 mm.
The steel section has 310mm web, 254mm flanges of 16mm thicknesses and 10mm web
thickness.

5. Draw the longitudinal cross-section “X-X” of the foundation plan given below. The thickness
of all the footings is 700 mm, and the columns are 400 x 400 mm each. The foundation is 1200
mm below the ground surface. Assume any data missing.

1
2
1 2 3 4 5

A A

B B

C C

D D

E E

F F

G G

H H

I I

0.3 5.7

6.0 6.0 6.0 6.0


24.3

1 2 3 4 5

Complete Floor Plan


24.3
24.0
6.0 6.0 6.0 6.0
1 2 3 4 5
Section
4.25

2.00

First Floor
Plan
3.60

2.75 1.00

3.60

0.25
0.15

Section
Clay bricks 3"x6"
Air space 1"
wood studs 6"x2" window frame
Vapor Barrier

plywood 34"

wool insulation

Dry wall 58"

3" 1"
3"
4
5" 6"
8
2"
1'-4" 5'
W 310x86

Flange
T=16mm
Connection Bolt

Plate Plate
90x90mm 90x90mm
T=10mm T=10mm

Concrete Base
Anchoring Bolts 510x750x600 mm
1 2 3 4

Street Level
0.0

Foundation Level
0.70
-0.7 m

1.00 1.50 1.20 1.20

3.00 5.00 4.00

S-ar putea să vă placă și