This document summarizes calculations checking the assembly connection for a utility area at Princess Noura Bint Abdulrahman University for Women Project in Riyadh, Saudi Arabia. The calculations verify that the bolts, connection plates, and welds are sufficient to withstand the shear and tension forces from a fresh concrete pressure of 80.427 kN/m^2 applied over a 2.8m width and around a 0.6m curved part. All components were found to have sufficient capacity based on their material strengths and dimensions. A stiffener is required for the bending of the connection angle flange.
This document summarizes calculations checking the assembly connection for a utility area at Princess Noura Bint Abdulrahman University for Women Project in Riyadh, Saudi Arabia. The calculations verify that the bolts, connection plates, and welds are sufficient to withstand the shear and tension forces from a fresh concrete pressure of 80.427 kN/m^2 applied over a 2.8m width and around a 0.6m curved part. All components were found to have sufficient capacity based on their material strengths and dimensions. A stiffener is required for the bending of the connection angle flange.
This document summarizes calculations checking the assembly connection for a utility area at Princess Noura Bint Abdulrahman University for Women Project in Riyadh, Saudi Arabia. The calculations verify that the bolts, connection plates, and welds are sufficient to withstand the shear and tension forces from a fresh concrete pressure of 80.427 kN/m^2 applied over a 2.8m width and around a 0.6m curved part. All components were found to have sufficient capacity based on their material strengths and dimensions. A stiffener is required for the bending of the connection angle flange.
Princess Noura Bint Abdulrahman University for Women Project Joint venture
Riyadh, Kingdom of Saudi Arabia El Seif/CCC
part / package: package 3 - Utillity area references: time: date: department: ENGINEERING 1:58 PM 1/16/2018 calcs by: Aleksandar Jankovic sr.str.eng
7. THE CHECK OF THE ASSEMBLY CONNECTION
The adopted connection designed to carry the load in……. 0.4 meter, vertically Adopted bolts are grade… 4.6 with dimater D= 30 mm, total No: 1 pcs The thickness of material connection plate T= 10 mm The width of connection plate,……………….B= 100 mm The steel grade ASTM A36 ,yield strength 245 N/mm2 The tension strength of the bolts….….. pbtcap= 240 N/mm2 The shear strength of the bolts.………..pbscap= 160 N/mm2 The bearing strength of the bolts………pbbcap= 460 N/mm2 The bearing strength of connect. part..pbcpcap= 460 N/mm2 The fresh concrtete pressure…………... pmax= 80.427 kN/m2 The width of the shuttering…………………..W= 2.8 m The radius of curved part………………...……R= 0.6 m The adopted size of the weld…..………..…..a= 5 mm The safety factor………………………………….. 2
The load per one connection:
The shear force per connection …………………..Fs=P*W*h/2= 45.03912 kN The tension force per connection……………..Ft=R*3.14*p*h/2= 30.304894 kN Shear force Fs= 90.07824 kN(factored)…….. tension force Ft= 60.609787 kN (factored)