Version 0.94(2014.08.

26) Registration of
Design No.
temperature changing
User setting temperature changing menu User setting humidity changing menu temp/humi.display changing cycle setting menu Save in memory
s
www.conotec.co.kr Temperature output
Humidity output
Save in memory

Digital temp./humi. controller H


temp. output
humidity output
Digital temp./humi. sensor application
Applicable in the high temperature
upto 80

Setting groupt selection Humidity setting group selection Temp. setting group selection

temp. output humidity output


machine
(load)
When select When select
temp. output humi. output
cooling heating temp. output type select Humidity output type select humidifying heating
series

Read carefully this instruction manual before use and use temp. output delay time setting Humidity output delay time setting

the product properly.


The specifications, appearance and dimension may be changed 0.00 0.00
for improvement of performance without a prior notice
temp. output deviation
WARNING Single deviation setting double deviation setting type select Humidity output deviation type select Single deviation setting double deviation setting
1. This product is not made as a safety device, so when it is used for
a control of devices feared to cause casualties, damages to the
peripheral devices or huge property loss, the double safety 9
devices should be arranged before use.
2. Avoid connecting lines, checking and repairing the products while
power is supplied.
3. Connect power after making sure the terminal number. temp. output
4. Never disassemble modify, improve or repair the product. deviation setting Humidity output deviation setting

Be well-informed of how to use, safety regulations, warnings, etc 0.1 0.1


before installation of this device and apply it to the extent of the defined
specifications and relevant capacity without fail.
Avoid wiring or installation to a motor or solenoid with a large inductive load.
Use a shiled cable for extention of the sensor and ensure not to make it longer temp. sensor correction Humidity sensor correction
than the necessity.
Ensure not to use the parts generating arc when switching at the same power
External size & panel size
source or near to it.
Keep the power cable away from a high-tention power line and ensure not to 0.0 0.0
install it at a place with serious oil and dirt.
Avoid strong magnetic field or serious noise, vibration or impact.
Keep away from the place where strong alkaline or acid material is directly
released and use an independent pipe line. address setting Sensor heating set heating enable heating unable
When it is installed at kitchen, ensure not to pour water directly over the product
for cleaning.
Keep the sensor cable away from signal line, power source, power line or
loaded line and use an independent pipe line.
Note that the mark of in terminal connection diagram is the safety
expression for warnings or cautions.
Avoid using the product close to the device generating noises(high frequency
communication speed setting
welder, high frequency sewing machine, high frequency radio, large capacity
SCR Controller, etc).
The use in any way other than what is instructed by the manufacturer may
cause injury or property loss.
It is not a toy and keep it out of reach of children’s hand.
The installation of the device should be performed by an expert or a qualified
personnel without fail.
We shall not take any responsibility for the damage caused by non-compliance
with the above-mentioned warnings or cautions or by any consumer’s mistake. Unlock Lock Program lock setting

DANGER
Attention, Danger related to electric shock
Electric shock -Do not touch AC terminal during application of
electric current. It may cause electric shock.
Cut the power supply without fail during checking the input power.
7 13 Setting the output type for humidity 9
1 Setting menu for user’s temperature ② ADDRESS CODE
14
- Set the temperature point for the relay output < DS-SH series >
2 Setting menu for user’s humidity DS-SH A H FOX-2SHTR

- Set the humidity point for the relay output an


A(Humidity Accuracy) H(Housing Type)
3 Setting time for the display changing temp. & humi. display. - Set humi.: 50.0%Rh, : 1.30, : 1.0
When is the output turned ON? - 0 : ±4.5% - 04 : Stainless Body Length 40mm(Ambient temp. : to 80℃)
- Available to change the display in the state of present with While the present humidity increases, if passing over - 1 : ±3.0% - 12 : Stainless Body Length 120mm(Ambient temp. : 80℃)
the switch UP/DOWN. 51.0%Rh at the ‘B’ point, the relay turns ON at the ‘C’point - 5 : ±2.0% - 220 : Plastic Case
“Humi. display mode” “Temp.&Humi. display mode” “Temp. diplay mode” 50.0%Rh 51.0%Rh after 1min 30sec as setting time.
Please refer to that due to light the LED on the top of display (negative number : 2’s complement)
to fit each of display mode. 15 Setting the type of humidity deviation(Hysteresis)
4 Setting group selection menu
Humidity setting group selection Temp. setting group selection 16 Setting the deviation for humidity
5 Setting the output type for temperature. ⑦ Output- 0[30H]: Output OFF // 1[31H]: Output ON
cooling heating

40mm
6 Setting the output delay time for the temperature.
(shield)

120mm
(cooler, compressor,etc)

17 (shield)
- Set temp. : 25.0℃, : 1.30, : 1.0
When is the output turned ON?
While the present temperature increases, if passing over
26.0 ℃ at the ‘B’point, the relay turns ON at the “C’ point ex) An actual humidity value : 55.0% RH, the present humidity : 57.0%RH
25.0℃ 26.0℃ after 1min 30sec as setting time. If set the value by -2.0%RH, the present humidity will be displayed 55.0%
(temp.setting)

7 Setting the type of temperature deviation(Hysteresis)

8
18 above 11 How to diagnose a breakdown
Indicating ERROR on using items
This is the damage of memory data for various of inner-DATA due to be
10 (FOX-2SHTR)
got nosied strongly from outside while using this items. Please request us
: (cooling) : : (heating) : A/S by return. Although our controller is designed as the complementary
present present measures regarding these noise from outside, it is not endurable against
temperature temperature
setting + point that setting
temperature
point that these noise with endlessly.
temperature output ON output OFF
If noise(2KV) disordering become an inflow, the inner-part will be damaged.
setting point that point that
output OFF setting -
temperature
temperature
output ON
1200/2400/4800/9600/19200Bps
StartBit
: : : (heating) :
(cooling)
8 StopBit
present
temperature ParityBit or displayed when exceeding the range of humidity.
setting + point that setting + point that
temperature
setting temperature
output ON temperature output OFF DataBit Even if the ambient humidity of environment remaining in the normal
Protocol BCC state, these characters to be displayed, please request us A/S by return
setting -
temperature
point that
output OFF
setting -
temperature
point that
output ON
Temp. setting -39.9~119.9℃ 10.0℃ * WARRANTY PERIOD : 1 YEAR FROM THE DATE OF PURCHASE
Type setting
/
Temp.
for output
Output delay 1
9 Correction of the present temperature. time setting high
<rank > < N >
setting Type setting for
output deviation / When using this product, please observe the information of caution &
Setting for RX(-) warning due to give rise to disordering.
output deviation 0.1 ~ 19.9 0.1 (B-)
FOX-2SHTR Regarding the English-language manual, please download it at out
ex) An actual temperature : 55.0℃, the present temperature : 57.0℃ F Temp. correction -10.0 ~ +10.0 0.0 TX(+) (A+) homepage.
if set the value as -2.0, the present temperature will be F O
Humidity setting 0.0~100.0%Rh 30.0%Rh
displayed 55.0℃ O x Type setting
/
temperature x l for output
(A+) (B-) (A+) (B-)
l 2 Output delay

temperature 2 S Humi. time setting FOX-2SHTR FOX-2SHTR


Type setting for
/
S H setting output deviation

RS485 Communication address setting


Setting for
0.1 ~ 19.9 0.1
10 H T output deviation 2
TR W
T
Humidity
correction -10.0 ~ +10.0 0.0 e-mail : conotec@conotec.co.kr
Sensor’s heating URL : www.conotec.co.kr
R setting / STX 101 100 R/W X/D T P 0 ETX BCC
11 RS485 Communication speed setting /
Common START ADDRESS HEADER EN D BCC
TR Temp.&Humi.
changing display time 1 ~ 30sec 2sec CODE CODE CODE CODE CODE

W
01 ~ 99 01
(1200Bps)
12 Setting data lock function (2400Bps) STX 101 100 R/W X/D T P 0 ETX BCC
(4800Bps)
(9600Bps) (9600Bps) START
CODE
ADDRESS
CODE
HEADER
CODE
EN D BCC
CODE CODE

Lock on Lock off (19200Bps)