Principle of Measurement
• When the ultrasonic signal is transmitted through the flowing liquid, there will be a
difference between the upstream and downstream transit time (travel time or time of
flight), which is proportional to flow velocity, according to the formula below.
Computational Formula
Downstream Transducer
Tdown
Flow Tup D
Remarks:
V Medium Velocity Upstream Transducer
M Ultrasonic frequency of reflection
D Pipe Diameter
θ The angle between the ultrasonic signal and the flow
Tup Transit time in the forward direction
Tdown Transit time in the reverse direction
ΔT = Tup – Tdown
Introduction
FT101 transfer time ultrasonic flow meter
• Wall mount, transducers time ultrasonic flow
Software.
What’s TGA?
• Increase the single strength. The increase of signal strength is more easy to penetrate for
various kinds of scale, rust inside the pipe and inner lining. The maximum tolerable
cement inner is 18mm. With the enhanced transducers, the biggest clamp on type
transducers we used in field is DN2000mm.
Transducers (Sensor)
• Use our own manufacturing process and matching technology. The zero range can
be controlled at < 0.03 m/s.
• Delta Time between the up and Down stream transducer<2 nanoseconds, to make
sure we measure the real time.
• Clamp on type transducers easy to install, no need to break the pipeline or stop the
equipment. Especially the measurement of acid and alkali, only clamp on the pipe
could get the flow rate .
Specification
Application
• Our products have been promoted to many different countries and widely
application in water treatment, building automation, petrochemical industry,
agriculture, producing process monitor and control, etc.
• Ultrasonic flow meter use to measure the single medium, such as the pure water,
cooling water, water, chemical, oil, milk, etc.
• Because clamp on type sensor install don’t need to break the pipe, so it widely use
in the application which hard to cut off water, or use to measure the strong acid
and alkaline liquid because it not need to touch the liquid.
• We have the ability to customization depend on the environment, especially the
pipe size under DN25
Application
Satisfied the requirement of the flange connection and the spool pieces . The biggest
pipe size we had in field is DN2600.
• Application in Taiwan water treat company