Sunteți pe pagina 1din 4

GE Power & Water

Distributed Power

JGS 616 DS
PRELIMINARY DATA, dated 2014-04-08

www.ge-distributedpower.com Preliminary, subject to change


616diesel@ge.com
GE Power & Water
Distributed Power

JGS 616 DS

GENSET data in continuous operation: Additional information:


Electrical output at p.f. = 1 (7) kWe 2,557 Sound pressure level of genset dB(A) 104
Electrical output at p.f. = 0.8 (7) kWe 2,541 Sound pressure level of exhaust gas dB(A) 121
Mechanical output (1) kW 2,620 Exhaust gas volume at 465 °C and nominal power m³/h 29,220
g/kWh 188.0 Max. admissible exhaust back pressure mbar 30
Fuel Consumption (3, 4)
l/h 593.4 Exhaust gas temperature at 100% load °C 465
Engine jacket water (HT circuit) (2, 3) Combustion air volume at 25 °C and nominal power m³/h 12,060
kW 1,022
Intercooler 1st stage (HT circuit) (2, 3) Max. inlet cooling water temperature (LT- circuit) °C 54.4
Intercooler 2nd stage (LT circuit) (2, 3) Approx. outlet cooling water temperature (LT- circuit) (8) °C 62.2
kW 461
Lube oil (LT circuit) (2, 3) Water flow rate (LT- circuit) m³/h 57.0
Surface heat (5) kW 154 Max. inlet cooling water temperature (HT- circuit) °C 73.9
Emission values: NOx < 1,460 mg/Nm³ (15% O2) Approx. outlet cooling water temperature (HT- circuit) (8) °C 86.1
Water flow rate (HT- circuit) m³/h 79.5
Max. pressure drop of air intake filter mbar 20

Engine data: Alternator:


Engine type 616 Manufacturer TD Power Systems (6)
Configuration V 60° Type TD125-F2K7 (6)
No. of cylinders 16 Type rating kVA 4,500
Bore mm 190 Efficiency at p.f. = 1,0 % 97.6%
Stroke mm 220 Efficiency at p.f. = 0,8 % 97.0%
Piston displacement lit 99.80 Ratings at p.f. = 1,0 kW 2,557
Nominal speed rpm 1,500 Ratings at p.f. = 0,8 kW 2,541
Mean piston speed m/s 11.0 Frequency Hz 50
BMEP at nominal power bar 21.00 Voltage kV 10.5
Compression ratio Epsilon 16.0:1 Protection Class IP 23
Continuous power kW 2,620 Insulation class F
Weight dry kg 13,500 Speed rpm 1,500
Refilling capacity lube oil l ≈ 650 Mass kg 17,400

1) At standard reference conditions per ISO 3046-1:2002E, ISO 8665 and ISO 8528-5:2010 and continuous operation
2) Thermal output with tolerance of ±8%
3) New unit, continuous operation (no overload)
4) Fuel consumption based on EN 590 fuel with assumed LHV 42700 kJ/kg, density 830 g/l and tolerance of +5%
5) Only valid for engine and generator; Peripheral equipment is not considered (at p. f. = 0,8)
6) GE Jenbacher reserves the right to change the generator supplier and the generator type
7) According to VDE 0530 REM / IEC 34.1 with relative tolerances
8) Based on 30% gylcol

Standard conditions: Air pressure: 1000 mbar (14.50 psi) or 100 m (328ft) above sea level
Air temperature: 25 °C (77 °F) or 298 K
Relative Humidity: 30%

Definition of output: Net break power that the engine manufacturer declares an engine is capable of delivering continuously,
at stated speed, between the normal maintenance intervals and overhauls as required by the manufacturer.
Power determined under the operating conditions of the manufacturer’s test bench and adjusted to the standard conditions.
Overload: 5% capability according to ICxN 5% (1h in 12h period)

Engine output rating: Installation at an altitude = 0 m and an air intake temperature ≤ 50 °C (T1)

Fuel quality: TA 1000-0001

All data are based on engine full load at specified media temperatures and are subject to change.
The technical instruction TA 1100-0110DS "Boundary Conditions for GE Distributed Power Jenbacher diesel engines" must be strictly observed.
GE Power & Water
Distributed Power

Scope of supply genset JGS 616 DS

Basic engine equipment: Genset equipment:


- Two exhaust gas turbochargers - Base frame for diesel engine, alternator and heat exchangers
- Intercooler, two stage - Internal pole alternator with excitation alternator and
- Lubricating oil pump (gear driven) with automatic voltage regulator; p.f. 0.8 lagging to 1.0
- Lubricating oil filters in main circuit - Flexible coupling, bell housing, anti-vibration mounts
- Lubricating oil heat exchanger - Air filters
- HP fuel pumps for common rail system - Wiring of components to ECU
- Fuel-, lubricating oil and jacket water pipe work on engine - Crankcase breather
- Flywheel for alternator operation - LP fuel pump with water separator and filter
- Exhaust gas manifold
- LT & HT water pumps (mechanical driven)
- LT & HT temperature control valves

Engine accessories: Control equipment:


- Electric starter motor - Genset-Management-System DIA.NE XT4 with Touch Display
- Transducers and switches for oil pressure, charge air pressure, * Visualisation (industry PC with 15'' color graphics display):
jacket water temperature and pressure Operation data, controller display, exhaust gas temperature, etc.
- Jacket water electrical preheating (option) * Central genset control:
Speed-, power output and overspeed control,
Generator circuit breaker control, etc.
Documentation: - Multi-transducer
- Operating and maintenance manual - Demand switch
- Spare parts manual - Engine control unit (ECU)
- Drawings - Remote connection (option)

Assembly, painting and testing in Jenbach / Austria

Preliminary, subject to change


Scope of Supply & Design Subject to Local Regulations and product development
GE Power & Water
Distributed Power

Genset JGS 616 DS

Main dimensions and weights (approximate value) Connections (at genset)


Length L mm 8,400 High temperature water inlet and outlet DN/PN 100/10
Width B mm 2,050 Low temperature water inlet and outlet DN/PN 65/10
Height H mm 2,550 Exhaust gas outlet DN/PN 2x 350/10
Weight empty kg 37,900 Lube oil DN/PN 28/10
Weight filled kg 38,900 Fuel DN 16

www.ge-distributedpower.com Preliminary, subject to change


616diesel@ge.com

S-ar putea să vă placă și