43 Maintenance Manual
PA-25 V.43
MAINTENANCE MANUAL
PA-43 -1
PA-25-V.43 Maintenance Manual
Index
0. INTRODUCTION ....................................................................................................................... 3
0.1. GENERAL INFORMATION ....................................................................................................... 3
0.2. SAFETY STANDARDS ............................................................................................................ 4
0.2.1. Signs present on the machine .............................................................................. 5
0.2.2. General precautions to prevent danger ............................................................... 5
0.3. PERSONNEL TRAINING ......................................................................................................... 6
0.3.1. Maintenance............................................................................................................ 7
0.4. DANGEROUS AREAS IN THE MACHINE .................................................................................... 7
0.4.1. Moving conveyor belts .......................................................................................... 8
0.4.2. Troughs ................................................................................................................... 8
1. GENERAL CHARACTERISTICS ....................................................................................................... 9
2. MACHINE DESCRIPTION .............................................................................................................. 11
2.1. AUTOMATIC WEIGHING MACHINE ......................................................................................... 11
2.1.1. Bedplate ................................................................................................................ 11
2.1.2. Feeder conveyor................................................................................................... 11
2.1.3. Loading sensor cell and troughs........................................................................ 11
2.1.4. Exit conveyor........................................................................................................ 11
2.1.5. Controls and electric unit .................................................................................... 11
2.1.6. Elevator conveyor ................................................................................................ 12
3. INSTALLATION AND COMMISSIONING ........................................................................................... 13
3.1. LEVELLING ........................................................................................................................ 13
3.2. CONNECTING PRODUCT ELEVATOR TO W EIGHING MACHINE ................................................ 13
3.3. CONNECTION TO THE MAINS ............................................................................................... 14
3.3.1. Verifying motor rotation direction ...................................................................... 15
3.4. CHANGING THE VOLTAGE................................................................................................... 16
3.5. CONTROLS ........................................................................................................................ 17
4. CONNECTION TO PACKING MACHINES AND FEEDERS .................................................................... 19
4.1. CONNECTION AND LEVELLING VIS-À-VIS THE PACKING MACHINE............................................ 19
4.2. INTERCONNECTING CONTROL SIGNALS BETWEEN MACHINES ................................................ 20
4.3. CONNECTION TO THE POWER SUPPLY ................................................................................. 21
4.3.1. Connection to return or distributor belt............................................................. 22
4.3.2. Connection to feeding tank ................................................................................. 23
4.4. ADJUSTING THE ELEVATOR CONVEYOR HOPPER .................................................................. 24
4.5. BLOCKING TORQUE LIMITING ADJUSTMENT .......................................................................... 25
4.6. TIGHTENING AND CENTRING THE BELTS............................................................................... 26
5. ELECTRICAL WIRING................................................................................................................... 27
PA-43 -2
PA-25-V.43 Maintenance Manual
0. INTRODUCTION
PA-43 -3
PA-25-V.43 Maintenance Manual
PA-43 -4
PA-25-V.43 Maintenance Manual
Respect all the danger and care signs, consult the manual and pay attention to the
adhesive labels on the machine.
Only specialised electrical technicians should work on the electrical installation
and with the electric unit.
Work safety rules, governed by the official bodies in each country, should be
strictly observed.
If the machine stops while in operation, the head of maintenance should be
notified of the problem and the relevant circumstances.
The working space around the machine must be kept free of obstacles, clean and
well-lit.
Operators must wear suitable clothing according to work safety standards. Hair
must not be worn loose.
Cleaning operations should not be performed while machine parts are moving.
Do not remove safety or machine protective devices.
Only trained personnel are to use the machine.
PA-43 -5
PA-25-V.43 Maintenance Manual
The operators using this machine must be duly qualified and trained in the
machine’s ordinary operation and use. Operators should be trained by qualified
technicians once the machine is installed in its final location, or on the
manufacturer/distributor’s premises.
PA-43 -6
PA-25-V.43 Maintenance Manual
0.3.1. Maintenance
The setting, lubricatin and conservation points are located outside the dangerous
areas, so that these operations can be carried out when the machine is stopped.
All cleaning operations inside and outside the machine can be carried out safely
when the machine is stopped.
Extraordinary maintenance operations are to be carried out by specialist
technicians, who have the necessary equipment and have been trained
beforehand in the machine’s operation equipado and the safety devices.
ATTENTION
A dangerous area is any space inside and/or around a machine where somebody
is exposed to a health risk.
In the PA-25 automatic weighing machine, all the safety measures have been
adopted with respect to providing protective devices to all moving and accessible
mechanisms.
According to this PA-25 weighing machine’s operation, the “exposed person”
refers only to the “operator” responsible for starting and stopping the machine.
Under normal operating conditions, the operator must not be exposed to the
dangerous areas in the machine, because the machine normally operates
automatically from the time the product is loaded until it reaches the packing
machines.
Under normal, expected operation conditions, i.e.: with a continual weighing
process, the PA-25 weighing machine does not expose operators to any kind of
risk. Any machine risks have been eliminated or reduced owing to the machine’s
safety-orientated design, placing guards and protective devices, where
appropriate, in the risk areas during maintenance and setting.
However, generally speaking, there are some areas in the machine that represent
a residual danger which, owing to their nature, cannot be provided with any
protective device. These areas may cause injuries by dragging, trapping or
catching the operator’s limbs. Therefore, the operators using the machine must be
PA-43 -7
PA-25-V.43 Maintenance Manual
trained in the various danger situations, which may cause injuries owing to the
mechanical action of the various machine elements. When the machine is on, do
not touch, place hands inside, handle or rest on these areas, which are indicated
below:
- Moving conveyor belts
- Troughs
0.4.1. Moving conveyor belts
These are located at the bottom of the machine, for the product exit (exit
conveyor), and at the top, for the product inlet (feeder conveyor).
The product elevator also has a conveyor belt which lifts the product on to the
product conveyor belt for entering the weighing machine.
The conveyor belts are protected on the sides to prevent gashes caused in the
vicinity of the driving rollers.
The belts can cause injury by dragging, trapping or catching the operator’s limbs.
The operators using the machine must be trained in the various danger situations,
which may cause injuries owing to the mechanical action of the various machine
elements. Do not place hands or rest on these areas.
0.4.2. Troughs
The troughs are located around a plate at the top of the machine. They are used to
hold the product that is to be weighed, and move in a circular motion around the
plate that supports them. It is difficult for operators to access the troughs because,
apart from the protective devices provided, the only part that is not protected, for
operating requirements, is the top and owing to its height it is difficult to access.
The troughs can cause injury by dragging, trapping and catching the operator’s
limbs. The operators using the machine must be trained in the various danger
situations, which may cause injuries owing to the mechanical action of the various
machine elements. When the machine is on, it is strictly forbidden to handle or
place hands in this area.
PA-43 -8
PA-25-V.43 Maintenance Manual
1. GENERAL CHARACTERISTICS
PA-43 -9
PA-25-V.43 Maintenance Manual
Figure 1
PA-43 -10
PA-25-V.43 Maintenance Manual
2. MACHINE DESCRIPTION
The PA-25 model is made up of two units. The automatic weighing machine and
the elevator conveyor.
PA-43 -11
PA-25-V.43 Maintenance Manual
PA-43 -12
PA-25-V.43 Maintenance Manual
3.1. LEVELLING
First of all, assemble the bedplate to the bottom of the machine, according to the
following instructions. See Figure (2)
First mount the four levelling screws (A), with their corresponding nuts, in the
threaded drill holes on the bottom of the machine (B), making sure that the heads
of said screws fit into the grooves provided for this purpose on the supplements
(C). Once this part of the machine is set up, raise the weighing machine until the
four screws (D) and their washers (E) can be mounted in the upper threaded drill
holes at the bottom of the machine (B). Then tighten the screws. The screws can
be levelled using a 30 mm wrench on the screw heads (A) and attaching the
corresponding nuts.
Figure 2
PA-43 -13
PA-25-V.43 Maintenance Manual
Before connecting the weighing machine to the mains, the product elevator must
be connected to the PA-25 weighing machine.
This connection is made as follows:
• Remove the cover from the electric cabinet (A), pass the cable (B) through the
packing glands (C) and connect it to the output from the magneto-thermal
breaker (RST) in the elevator contact unit (D). See Figure (4) and wiring
diagram (Appendix I)
• Place the photocell (E) in its corresponding support (F) provided opposite the
elevator motor reducer. This photocell (E) is connected to an electric control
box, attached to the rear of the machine, and therefore it includes a signal
selector that connects or disconnects the elevator from the weighing machine
control. This signal selector can be used as an emergency stop for the
elevator, but the elevator can only be started-up from the control panel. See
Figure (3)
Figure 3
D – (Elevator)
Figure 4
PA-43 -14
PA-25-V.43 Maintenance Manual
Figure 5
PA-43 -15
PA-25-V.43 Maintenance Manual
Mains connection cable: This is a 5-pole cable, including neutral and earth. It
must be connected as shown in Figure (6)
Motors: In the above-mentioned motors, the jumpers on the terminal boxes must
be changed to a supply voltage of 220 V, as indicated in Figure (6).
[Brown] [Blue]
Figure 6
PA-43 -16
PA-25-V.43 Maintenance Manual
3.5. CONTROLS
The machine is controlled using a tactile screen, stop and start-up buttons and an
emergency button or push-button.
A.- Tactile screen
B.- ON button with green pilot light
C.- OFF button with red pilot light
D.- Emergency push-button (OFF), which is red when locked.
E.- General switch
Figure 7
The machine is commissioned from the general switchboard, by pressing button
(B) that has been designed for this purpose and which leaves the machine on
standby. Then use the tactile screen (A) on the actual machine, to control and
start-up the machine.
An emergency button (D) is provided, and when this is pressed the machine stops.
When the emergency switch is unblocked, the machine will not start-up again until
the the controls are reset. After an emergency stop, the machine can be started-up
easily from the general switchboard.
Use button (C) to stop the machine safely.
PA-43 -17
PA-25-V.43 Maintenance Manual
If the power supply is interrupted, the machine will stop and, when the power is
restored, machine operation will not release, even though the indicators are
working, until a new order is given.
A fault in the control circuit cannot cause the machine to start-up unexpectedly or
prevent a manually controlled emergency stop.
PA-43 -18
PA-25-V.43 Maintenance Manual
The PA-25 weighing machine and any packing machines we manufacture, are not
attached.
To level the packing machine, the packing hopper (A) must be centred perfectly
with respect to the weighing machine exit conveyor (B) and, the hopper must be
placed at a distance of approximately 5 mm, making sure that the hopper inlet
mouth is also centred vertically with the conveyor belt rotary shaft, using the
corresponding leveling screws (C). See Figure (8).
Figure 8
PA-43 -19
PA-25-V.43 Maintenance Manual
The PA-25 weighing machine exit conveyor belt has two feed directions and so a
packing machine can be attached at each side.
To electrically connect the weighing and packing machines, remove the protective
cover (A) [Figure 8] to access the connection terminal gauge (B). Pass the electric
cables through the packing glands (C). Consult the wiring diagram (III).
When the packing machine is prepared for packing, it sends a signal to the
weighing machine and the weighing machine saves this signal in its memory until
a product has been correctly weighed. Then it unloads the product into the packing
machine and at the same time sends the packing machine a signal to start its
packing cycle.
If the weighing machine does not receive the signal from the packing machine, the
trough carrousel will remain full and keep rotating. Also on the exit conveyor belt,
the last product will remain stationery until the relevant signal is received from the
corresponding packing machine.
Figure 9
PA-43 -20
PA-25-V.43 Maintenance Manual
PA-43 -21
PA-25-V.43 Maintenance Manual
Figure 10
PA-43 -22
PA-25-V.43 Maintenance Manual
Figure 11
PA-43 -23
PA-25-V.43 Maintenance Manual
Figure 12
PA-43 -24
PA-25-V.43 Maintenance Manual
The machine carrousel motor transmits its power via a limiting torque, mounted on
the reducer shaft. See Figure (13). This limiter must be correctly adjusted so that
the machine stops, giving off an alarm, when a product is placed incorrectly in the
troughs as it is conveyed inside the machine.
This torque limiter has a pulling hub (A), on which the transmission gear (B) is
mounted between two friction rings (C) and attached by the pressure they apply to
the nuts (D) by means of the springs (E), housed in the disks (F).
To make a correct adjustment, tighten the nut (D) in a series of half turns until it no
longer slipsand then give it one more half turn for safety.
Figure 13
PA-43 -25
PA-25-V.43 Maintenance Manual
The PA-25 weighing machine uses three conveyors to transfer the product. The process
for tightening and centring the corresponding belts is the same in all three cases:
Elevator conveyor, see Figure (14)
Inlet conveyor, see Figure (15)
Exit conveyor, see Figure (16)
The driven roller (A) on the three conveyors is mounted on tightening devices (B) that
enable the belt to be centred and tightened so that it operates correctly. The belts must be
tightened sufficiently, but not excessively, so that the belt does not slip on the rollers. The
belts are centred always by tightening the tightening screw on the side on which the belt
tends to slip, or, by loosening the belt on the other side.
The product exit conveyor belt, as it as two feeding directions, is fitted with a double
centring system, although only the tightening devices on the left side of the conveyor are
adjusted. See Figure (16).
Figure 14 Figure 15
Figure 16
PA-43 -26
PA-25-V.43 Maintenance Manual
5. ELECTRICAL WIRING
List of all the electrical diagrams in each version of the PA-25-v.43 machine that
are attached as appendices with the following manual:
PA-43 -27
PA-43
NORMAL
C0
S1 TO-2-8293-E+SVB LP1K0910
VALIDA
7 8 L1 5 6
L1
5 6 L2 3 4
L2
3 4 L3 1 2
L3
1 2
N
TIERRA TIERRA
FILTRO RED
RC 380 X 3
C1 C2
KITAGAWA
LP1K 0910BD
13 13
LP1K 0610BD
14 14
LR 2K.030X LR 2K.030X
LR 2K 0306 a
LR 2K 0308 a 380V U45
2T1
4T2
6T3
2T1
4T2
6T3
380V y 220V
LR2K0310 a 220V
L1
L2
L3
TIERRA
S1
S2
F1 F2 S3
S4
S5
SC VARIADOR YASKAWA
CIMR-J7AZB0P2
TIERRA
L1 L2 L3 N
5A 5A
T1
T2
T3
PUENTE
MANGUERA DE
TIERRA
Modificaciones 1 2 3 4
230V A CUADRO
ELECTRONICO Tratamiento
Fecha Nombre
Plano 1 de 9
Dibujado Thursday, March 16, 2000 Ramón
L1 L2 L3 N
Calcado Peso Clave Numero de plano
PESADORA ASOCIATIVA E-43-08-0100E
Revisado Monday, August 01, 2005 Oscar
A TOMA DE RED Modelo
Escala Cantidad Sustituye
ELECTRICA
CUADRO ELECTRICO 1/2
PA-43
Sustituido
TRIFAS. 380V
L1 R
L2 S
L3 T
LP1K0601
LP1K0601 LP1K0601
5
C4 LP1K0601 C5 C6
5
21
21 21 21
22 RC 380 X 3 RC 380 X 3
22 22
22
LR2K0306 a 380V LR2K0306 a 380V
2
LR2K030X LR2K030X
6
LR2K0307 a 220V LR2K0307 a 220V
2T1
4T2
6T3
2T1
4T2
6T3
L1
L2
L3
LR2K0306 a 380V
LR2K0307 a 220V
T1
T2
T3
RC 380 X 3
BORNAS REGLETERO
M M M
MOTOR 0,25 C.V.
CINTA SAL.1 ( MOTOR 0,25 C.V. MOTOR 0,25 C.V.
DERECHA E CINTA EXTERIOR CINTA EXTERIOR
IZQUIERDA) DERECHA IZQUIERDA
Modificaciones 1 2 3 4
Tratamiento
Fecha Nombre
Plano de
Dibujado Thursday, March 16, 2000 2 9
Ramón
S3
P3
PARO
BLANCO-ROSA 14 13
21 X6
B-70
70
R1
RELE SCHRACK (ZT5700024)
28
B-64
64 27
13
7
R1 R-C 26
ENVASADORA
380V 25 DERECHA
B-70
70
14
11
5 X4
S. A ENVASADORA
27 X6
S. DE ENVASADORA
R2
RELE SCHRACK (ZT5700024)
38
B-64
64 37
13
7
R2 R-C 36
ENVASADORA
380V 35 IZQUIERDA
B-70
70
14
11
6 X4
S. A ENVASADORA
28 X6
S. DE ENVASADORA
15 X6
19 19
+ IA12DSN04NO
23 X6
18 18
S E5 SINCRONISMO
27 X6
14 14
- 18
19
+ IA12DSN04NO
22 X6
17 17
S E4 ORIGEN
14
- 17
12
15 X5 D3
16 X5
1N4007 A DELGA SOPORTE DETECTORES
14 X5 MONTADO EN
13 X5 PLATO
CARROUSEL
1 X6
Modificaciones 1 2 3 4
B-70
Tratamiento
Fecha Nombre
Plano 3 de 9
Dibujado Ramón
70 Monday, February 19, 2001
21
CARROUSEL COMPUERTA IZQUIERDA
PRODUCTO DERECHA IZQUIERDA
S1 C3 C4
64
95
A1
21
(CORTAR PATA
A1
A1
A1
22
C2 CONTACTOS C5 C6 S3
AUXILIARES DE
RELE TERMICO)
C1 EV1 P3
PARO
96 A2
96
96 A2
96 A2
96 A2
22
A1
A1
31 X4
16 X4
15 X4
14 X4
13 X4
C3 C4
21
A2
A2
13 95
95
95
95
22
22
26 X4 S5
9 X4 C4 C3
14
27 X4
21
21
1 X4
2 X4
13
13
3X4
4X4
S2
C0
V1 MARCHA
14
14
L1
L2
L3
TIERRA
P2
20X4 S1
21X4 S2
22X4 S3
23X4 S4 64
S5 MOTOR CINTA
SC VARIADOR YASKAWA ALIMENTACION
CIMR-J7AZB0P2
TIERRA
A1
C0
T1
T2
T3
70
13 X6 80
A2
"VALIDA"
25 X4
24 v
16 x6
Modificaciones 1 2 3 4
Tratamiento
24V 3W Fecha Nombre
28 X4 1 2 Plano 4 de 9
Dibujado Tuesday, February 20, 2001 Ramón
PIL. ALARMA Clave
Calcado Peso Numero de plano
24V 3W PESADORA ASOCIATIVA
1 2 Revisado Monday, August 01, 2005 Oscar E-43-08-0400E
12 X4
PIL. MARCHA Escala Modelo Cantidad Sustituye
13 X5
14 X5
15 X5
16 X5
A1
A1
A1
A1
A1
E1 E2 E3 E4 E5
A2
A2
A2
A2
A2
1
1 X5
2
2 X5
3
3 X5
4
4 X5
5
5 X5
A1
A1
A1
A1
A1
E6 E7 E8 E9 E10
A2
A2
A2
A2
A2
6
6 X5
7
7 X5
8
8 X5
9
9 X5
10
10 X5
MANGUERA ELECTROIMANES
Modificaciones 1 2 3 4
Tratamiento
Fecha Nombre
CI-9092 Plano 5 de 9
Dibujado Thursday, October 11, 2001 Ramón
51V 4W
80
11
16 X6 80
10
18 X6 70 PA18CSD04NASA
+
70 S PRODUCTO EN
E7
1 L
1 ELEVADOR
26 X6 1 - FOT14
+ PA18CSD04NASA
25 X6
2
2 S PRODUCTO EN
E8
L
2 CINTA
- FOT14
ALIMENTACION
+
24 X6
3
3 S E6 IA30DSN15NO
- 3 CUBETA ABIERTA
9 X4 7
8
3X4 8
9
4X4 9 EV 1
64
COMPUERTA
4
27 X4
13
5 SELECTOR
95 C2 ELEVADOR
ON/OFF
14
Modificaciones 1 2 3 4
Tratamiento
Fecha Nombre
Plano 6 de 9
Dibujado Tuesday, September 07, 2004 Ramón
-
-
+
+
d6 s1 s1
x6.13 d7 s2 x2.14 x1.14 s2
x6.14 ba1 X6 DISPLAY s3 x2.15 x1.15 s3
x6.15 r/w s4 x2.16 x1.16 s4
BASE x6.16 e vma x2.17 x1.17 vma
( 230 V AC) OMRON x6.17 cs s5 x2.18 x1.18 s5
x6.18 rst X2 s6 x2.19 x1.19 s6
x6.19 x2.20 x1.20
x6.20
gnd BUS I/O e
x2.21 x1.21
e
gnd bas bas
dtack x2.22 x1.22 dtack
DIP 20 watch x2.23 x1.23 watch
x2.24 x1.24
GND
r/w r/w
d7 x2.25 x1.25 d7
N
DIP 34
L
d6 x2.26 x1.26 d6
x7.1 in1 d5 x2.27 x1.27 d5
S8VS-03024 x7.2 in2 d4 x2.28 x1.28 d4
x7.3 in3 d3 x2.29 x1.29 d3
x7.4 in4 d2 x2.30 x1.30 d2 SALIDAS[1..32] X4[1..32]
x7.5 q1 d1 x2.31 x1.31 d1
x7.6 q2 d0 x2.32 x1.32 d0
x7.7 q3 X7 gnd x2.33 x1.33 gnd WEID 2 X 16
x7.8 x2.34 x1.34
x7.9
q4 TECLADO DIP 34
gnd gnd
q5
x7.10 q6
x7.11 q7
x7.12 q8
x7.13 nc
x7.14 gnd
x7.15 vcc X8
X8.1
FA-6Z POSTE 10 BUCLE CORR.
+B
X8.2
0B
Rx X8.3
Tx X8.4
N.C. X8.5 CONECTOR X3
T-511 WEID 5 TRANSFORMADOR
WEID 8 X3.1 24 P
KITAGAWA 11 x1.1 X3.2
11a 0P
x1.2 0a X3.3 19 SA
x1.3 11a X1 TRANSFORMADOR X3.4 0
PASADOS CON UNA VUELTA
CABLES LINEAS FASES
GND
GND
RTS
CTS
RTS
CTS
11
RX
RX
TX
TX
+V
S+
0V
S-
-V
0
X11.1
X11.2
X11.3
X11.4
X11.5
X10.3
X10.5
X10.7
X10.8
x10.2
X9.2
X9.3
X9.5
X9.7
X9.8
36 SA1
0 36 SA1
0 SA
24 OP
0 OP
24 P
19 SA
0P
200
230
0
245 0 0P
FERRITA KITAGAWA
PANTALLA TACTIL
0 SA1 0
verde 7
28 24 P
amarillo
gris
3
2
COM 2
0 4 DB25
5
36
36 SA1
20 azul+verde v+
0 SA 0 negro+amarillo v-
0 0 OP blanco s-
rojo s+
malla blindaje
19 SA 19 20 24 OP CELULA DE CARGA
Modificaciones 1 2 3 4
Tratamiento
Fecha Nombre
Plano 7 de 9
Dibujado Monday, February 19, 2001 Ramón
A3 ESQUEMA BLOQUES
PA-43
Sustituido
FUJI UG-22-HI-CS
+24V 1
GND 2
GND
DSR
DTR
RTS
CTS
RTS
CTS
Rx
Rx
Tx
Tx
P1 P2
P4
20
FICHA
2
3
5
7
8
2
3
4
5
6
7
14 13 21x6 14 13 70 70 14 13 19x6
DB25M
RX
TX
GND
20x6 14 13 70 21 22 21 64 64 22 21 60
a (X9) U1
FICHA 2 GRIS 12x4 16x6 28x4
3 AMARILLO
DB9 H 5 VERDE
PULSADOR
EAO DIFUSOR EAO DIFUSOR TIPO SETA
GND PANTALLA
VERDE ROJO
24V PANTALLA
PILOTO ( MARCHA ) PILOTO (ALARMA)
LAM. 24V LAM. 24V
(A1 C0)
20X6
12X4
16 X6
B-21 21
21X6
28X4
16 X4
CABLEADO A 17X6
31 X4
CUADRO 19X6
ELECTRICO
CABLEADO A
CUADRO Modificaciones 1 2 3 4
ELECTRONICO
Tratamiento
Fecha Nombre
Plano 8 de 9
Dibujado Thursday, July 27, 2000 Ramón
A4 CUADRO DE MANDO
PA-43 Sustituido
A2 RELE 2 1 1 6 x4
B-35 2 2 28 X6
3 3
B-64 4 4 64 (14X4)
B-70 5 5 70 (1X6)
A2 C0 6 6 25X4
A2 C1 (95 TERMICO) 7 7 26X4
A2 RELE 1 8 MANGUERA INTERCONEXION 8 5X4
BORNA 25 (ENVASADORA) 9 9 27X6
B-80 10 CUADRO ELECTRICO 10 13 X6
A CUADRO A2 C3 11 A CUADRO ELECTRONICO 11 1 X4 a CUADRO
A2 C4 12 12 2 X4
ELECTRICO A2 C5 13 13 3 X4 ELECTRONICO
A2 C6 14 14 4 X4
S1 V1 15 15 20 X4
S3 V1 16 16 21 X4
S4 V1 17 17 22 X4
S5 V1 18 18 23 X4
Modificaciones 1 2 3 4
Tratamiento
Fecha Nombre
Plano 9 de 9
Dibujado Thursday, July 27, 2000 Ramón
32
16
ENTRADAS
TRAFO
8
X1
X2
SCHUKO
X6
1 (MACHO)
17
BUCLE
CI-9030-A CI-9092
ALIMENTACION
CORRIENTE
1
S8VS-03024
5
FUENTE
X 10
1 (MACHO)
RS-232
COM 2
9
TRAFO
X3
X9
1 (MACHO)
8
RS-232
TRAFO
COM 1
T-511
1 17
32
1 5 1 5 1 5
16
1
16
( SIN USO ) ( SIN USO )
Modificaciones 1 2 3 4
Tratamiento
Fecha Nombre
Plano 1 de 1
Dibujado Friday, May 28, 1999 Ramón
TIERRA TIERRA
FILTRO RED
FA-6Z
KITAGAWA
LP1K 0910BD
13 13
LP1K 0610BD
14 14
LR 2K.030X LR 2K.030X
LR2K0306 LR2K0308 a 380V
U45
2T1
4T2
6T3
2T1
4T2
6T3
a220V y LR2K0310 a 220V
380V
L1
L2
L3
TIERRA
S1
S2
F1 F2 S3
S4
S5
SC VARIADOR YASKAWA
CIMR-J7AZB0P2
TIERRA
L1 L2 L3 N
5A 5A
T1
T2
T3
PUENTE
MANGUERA DE
TIERRA
Modificaciones 1 2 3 4
230V A CUADRO
ELECTRONICO Tratamiento
Fecha Nombre
Plano 1 de 9
Dibujado Thursday, March 16, 2000 Ramón
L1 L2 L3 N
Calcado Peso Clave Numero de plano
PESADORA ASOCIATIVA E-43-09-0100E
Revisado Monday, August 01, 2005 Guillem
A TOMA DE RED Modelo
Escala Cantidad Sustituye
ELECTRICA
CUADRO ELECTRICO 1/2
PA-43 D
Sustituido
TRIFAS. 380V
L1 R
L2 S
L3 T
5
C3 C4 C5 C6
21 21 21 21
LR2K0306 a 380V LR2K030X LR2K0306 a 380V LR2K030X LR2K0306 a 380V LR2K030X LR2K0306 a 380V LR2K030X
LR2K0307 a 220V LR2K0307 a 220V LR2K0307 a 220V LR2K0307 a 220V
2T1
4T2
6T3
2T1
4T2
6T3
2T1
4T2
6T3
2T1
4T2
6T3
BORNAS REGLETERO
M M M M
MOTOR 0,25 C.V. MOTOR 0,25 C.V. MOTOR 0,25 C.V. MOTOR 0,25 C.V.
CINTA SAL.1 ( DERECHA ) CINTA SAL. 2 ( IZQUIERDA ) CINTA EXTERIOR CINTA EXTERIOR
DERECHA IZQUIERDA
Modificaciones 1 2 3 4
Tratamiento
Fecha Nombre
Plano de
Dibujado Thursday, March 16, 2000 2 9
Ramón
S3
P3
PARO
BLANCO-ROSA 14 13
21 X6
B-70
70
R1
RELE SCHRACK (ZT5700024)
28
B-64
64 27
13
7
R1 R-C 26
ENVASADORA
380V 25 DERECHA
B-70
70
14
11
5 X4
S. A ENVASADORA
27 X6
S. DE ENVASADORA
R2
RELE SCHRACK (ZT5700024)
38
B-64
64 37
13
7
R2 R-C 36
ENVASADORA
380V 35 IZQUIERDA
B-70
70
14
11
6 X4
S. A ENVASADORA
28 X6
S. DE ENVASADORA
15 X6
19 19
+ IA12DSN04NO
23 X6
18 18
S E5 SINCRONISMO
27 X6
14 14
- 18
19
+ IA12DSN04NO
22 X6
17 17
S E4 ORIGEN
14
- 17
12
15 X5 D3
16 X5
1N4007 A DELGA SOPORTE DETECTORES
14 X5 MONTADO EN
13 X5 PLATO
CARROUSEL
1 X6
Modificaciones 1 2 3 4
B-70
Tratamiento
Fecha Nombre
Plano 3 de 9
Dibujado Ramón
70 Monday, February 19, 2001
21
CARROUSEL COMPUERTA
PRODUCTO DERECHA IZQUIERDA
S1
64
A1
21
A1
A1
A1
A1
A1
22
C2 C3 C4 C5 C6 S3
C1 EV1 P3
PARO
96 A2
96 A2
96 A2
96 A2
96 A2
96 A2
22
31 X4
16 X4
15 X4
14 X4
13 X4
21
13 95
95
95
95
95
95
26 X4 S5
9 X4
14
27 X4
1 X4
2 X4
13
13
3X4
4X4
S2
C0
V1 MARCHA
14
14
L1
L2
L3
TIERRA
P2
20X4 S1
21X4 S2
22X4 S3
23X4 S4 64
S5 MOTOR CINTA
SC VARIADOR YASKAWA ALIMENTACION
CIMR-J7AZB0P2
TIERRA
A1
C0
T1
T2
T3
70
13 X6 80
A2
"VALIDA"
25 X4
24 v
16 x6
Modificaciones 1 2 3 4
Tratamiento
24V 3W Fecha Nombre
28 X4 1 2 Plano 4 de 9
Dibujado Tuesday, February 20, 2001 Ramón
PIL. ALARMA Clave
Calcado Peso Numero de plano
24V 3W PESADORA ASOCIATIVA E-43-09-0400E
1 2 Revisado Monday, August 01, 2005 Oscar
12 X4
PIL. MARCHA Escala Modelo Cantidad Sustituye
13 X5
14 X5
15 X5
16 X5
A1
A1
A1
A1
A1
E1 E2 E3 E4 E5
A2
A2
A2
A2
A2
1
1 X5
2
2 X5
3
3 X5
4
4 X5
5
5 X5
A1
A1
A1
A1
A1
E6 E7 E8 E9 E10
A2
A2
A2
A2
A2
6
6 X5
7
7 X5
8
8 X5
9
9 X5
10
10 X5
MANGUERA ELECTROIMANES
Modificaciones 1 2 3 4
Tratamiento
Fecha Nombre
CI-9092 Plano 5 de 9
Dibujado Thursday, October 11, 2001 Ramón
51V 4W
80
11
16 X6 80
10
18 X6 70 PA18CSD04NASA
+
70 S PRODUCTO EN
E7
1 L
1 ELEVADOR
26 X6 1 - FOT14
+ PA18CSD04NASA
25 X6
2
2 S PRODUCTO EN
E8
L
2 CINTA
- FOT14
ALIMENTACION
+
24 X6
3
3 S E6 IA30DSN15NO
- 3 CUBETA ABIERTA
9 X4 7
8
3X4 8
9
4X4 9 EV 1
64
COMPUERTA
4
27 X4
13
5 SELECTOR
95 C2 ELEVADOR
ON/OFF
14
Modificaciones 1 2 3 4
Tratamiento
Fecha Nombre
Plano 6 de 9
Dibujado Tuesday, September 07, 2004 Ramón
-
-
+
+
d6 s1 s1
x6.13 d7 s2 x2.14 x1.14 s2
x6.14 ba1 X6 DISPLAY s3 x2.15 x1.15 s3
x6.15 r/w s4 x2.16 x1.16 s4
BASE x6.16 e vma x2.17 x1.17 vma
( 230 V AC) OMRON x6.17 cs s5 x2.18 x1.18 s5
x6.18 rst X2 s6 x2.19 x1.19 s6
x6.19 x2.20 x1.20
x6.20
gnd BUS I/O e
x2.21 x1.21
e
gnd bas bas
dtack x2.22 x1.22 dtack
DIP 20 watch x2.23 x1.23 watch
x2.24 x1.24
GND
r/w r/w
d7 x2.25 x1.25 d7
N
DIP 34
L
d6 x2.26 x1.26 d6
x7.1 in1 d5 x2.27 x1.27 d5
S8VS-03024 x7.2 in2 d4 x2.28 x1.28 d4
x7.3 in3 d3 x2.29 x1.29 d3
x7.4 in4 d2 x2.30 x1.30 d2 SALIDAS[1..32] X4[1..32]
x7.5 q1 d1 x2.31 x1.31 d1
x7.6 q2 d0 x2.32 x1.32 d0
x7.7 q3 X7 gnd x2.33 x1.33 gnd WEID 2 X 16
x7.8 x2.34 x1.34
x7.9
q4 TECLADO DIP 34
gnd gnd
q5
x7.10 q6
x7.11 q7
x7.12 q8
x7.13 nc
x7.14 gnd
x7.15 vcc X8
X8.1
FA-6Z POSTE 10 BUCLE CORR.
+B
X8.2
0B
Rx X8.3
Tx X8.4
N.C. X8.5 CONECTOR X3
T-511 WEID 5 TRANSFORMADOR
WEID 8 X3.1 24 P
KITAGAWA 11 x1.1 X3.2
11a 0P
x1.2 0a X3.3 19 SA
x1.3 11a X1 TRANSFORMADOR X3.4 0
PASADOS CON UNA VUELTA
CABLES LINEAS FASES
GND
GND
RTS
CTS
RTS
CTS
11
RX
RX
TX
TX
+V
S+
0V
S-
-V
0
X11.1
X11.2
X11.3
X11.4
X11.5
X10.3
X10.5
X10.7
X10.8
x10.2
X9.2
X9.3
X9.5
X9.7
X9.8
36 SA1
0 36 SA1
0 SA
24 OP
0 OP
24 P
19 SA
0P
200
230
0
245 0 0P
FERRITA KITAGAWA
PANTALLA TACTIL
0 SA1 0
verde 7
28 24 P
amarillo
gris
3
2
COM 2
0 4 DB25
5
36
36 SA1
20 azul+verde v+
0 SA 0 negro+amarillo v-
0 0 OP blanco s-
rojo s+
malla blindaje
19 SA 19 20 24 OP CELULA DE CARGA
Modificaciones 1 2 3 4
Tratamiento
Fecha Nombre
Plano 7 de 9
Dibujado Monday, February 19, 2001 Ramón
A3 ESQUEMA BLOQUES
PA-43 D
Sustituido
FUJI UG-22-HI-CS
+24V 1
GND 2
GND
DSR
DTR
RTS
CTS
RTS
CTS
Rx
Rx
Tx
Tx
P1 P2
P4
20
FICHA
2
3
5
7
8
2
3
4
5
6
7
14 13 21x6 14 13 70 70 14 13 19x6
DB25M
RX
TX
GND
20x6 14 13 70 21 22 21 64 64 22 21 60
a (X9) U1
FICHA 2 GRIS 12x4 16x6 28x4
3 AMARILLO
DB9 H 5 VERDE
PULSADOR
EAO DIFUSOR EAO DIFUSOR TIPO SETA
GND PANTALLA
VERDE ROJO
24V PANTALLA
PILOTO ( MARCHA ) PILOTO (ALARMA)
LAM. 24V LAM. 24V
(A1 C0)
20X6
12X4
16 X6
B-21 21
21X6
28X4
16 X4
CABLEADO A 17X6
31 X4
CUADRO 19X6
ELECTRICO
CABLEADO A
CUADRO Modificaciones 1 2 3 4
ELECTRONICO
Tratamiento
Fecha Nombre
Plano 8 de 9
Dibujado Thursday, July 27, 2000 Ramón
A4 CUADRO DE MANDO
PA-43 D Sustituido
A2 RELE 2 1 1 6 x4
B-35 2 2 28 X6
3 3
B-64 4 4 64 (14X4)
B-70 5 5 70 (1X6)
A2 C0 6 6 25X4
A2 C1 (95 TERMICO) 7 7 26X4
A2 RELE 1 8 MANGUERA INTERCONEXION 8 5X4
BORNA 25 (ENVASADORA) 9 9 27X6
B-80 10 CUADRO ELECTRICO 10 13 X6
A CUADRO A2 C3 11 A CUADRO ELECTRONICO 11 1 X4 a CUADRO
A2 C4 12 12 2 X4
ELECTRICO A2 C5 13 13 3 X4 ELECTRONICO
A2 C6 14 14 4 X4
S1 V1 15 15 20 X4
S3 V1 16 16 21 X4
S4 V1 17 17 22 X4
S5 V1 18 18 23 X4
Modificaciones 1 2 3 4
Tratamiento
Fecha Nombre
Plano 9 de 9
Dibujado Thursday, July 27, 2000 Ramón
32
16
ENTRADAS
TRAFO
8
X1
X2
SCHUKO
X6
1 (MACHO)
17
BUCLE
CI-9030-A CI-9092
ALIMENTACION
CORRIENTE
1
S8VS-03024
5
FUENTE
X 10
1 (MACHO)
RS-232
COM 2
9
TRAFO
X3
X9
1 (MACHO)
8
RS-232
TRAFO
COM 1
T-511
1 17
32
1 5 1 5 1 5
16
1
16
( SIN USO ) ( SIN USO )
Modificaciones 1 2 3 4
Tratamiento
Fecha Nombre
Plano 1 de 1
Dibujado Friday, May 28, 1999 Ramón
S1 L1 L1'
C0 LP1K0910
TO-2-8293-E+SVB 200V 220V VALIDA
7 8 R 8.5A R1 5 6
L1
5 6 S L2 L2' S1 3 4
220V L2
3 4
200V 1 2
T T1 L3
1 2 N N
L3 L3'
200V 220V
TIERRA
TIERRA TIERRA
RC 380 X 3
C1
C2
KITAGAWA
13
LP1K 0610BD
13
LP1K 0910BD
14
14
LR 2K 0307 LR 2K.030X
LR 2K 0310 LR 2K.030X
U45
2T1
4T2
6T3
2T1
4T2
6T3
L1
L2
L3
TIERRA
S1
S2
F1 F2 S3
S4
S5
SC VARIADOR YASKAWA
CIMR-J7AZB0P2
TIERRA
L1 L2 L3 N
5A 5A
T1
T2
T3
PUENTE
MANGUERA DE
TIERRA
Modificaciones 1 2 3 4
Tratamiento
Fecha Nombre
Plano 1 de 9
Dibujado Thursday, March 16, 2000 Ramón
L1 L2 L3 N T
Calcado Peso Clave Numero de plano
PESADORA ASOCIATIVA E-43-13-0100E
Revisado Monday, August 01, 2005 Oscar
A TOMA DE RED
ELECTRICA Escala Modelo Cantidad Sustituye
CUADRO ELECTRICO PA-43 JD
PA-43 JD
Sustituido
TRIFAS. 200V
SALIDA DE VALIDA
R1 R
S1 S
T1 T
N N
U48
5
C5 C6
KITAGAWA
KITAGAWA
RC 380 X 3 RC 380 X 3
22 22
LR2K030X LR2K030X
2T1
4T2
6T3
2T1
4T2
6T3
LR 2K 0306 LR 2K 0306
V3
V2
L1
L2
L3
TIERRA
L1
L2
L3
TIERRA
S1
S1 S2
S2 S3
S3 S4
S4 S5
S5 SC VARIADOR YASKAWA
SC VARIADOR YASKAWA
CIMR-J7AZB0P2
CIMR-J7AZB0P2
TIERRA
TIERRA
T1
T2
T3
T2
T3
T T T T
BORNAS REGLETERO
M M M M
MOTOR 0,25 C.V. MOTOR 0,25 C.V.
CINTA SAL.1 ( DERECHA ) CINTA SAL. 2 ( IZQUIERDA ) MOTOR 0,25 C.V. MOTOR 0,25 C.V.
CINTA EXTERIOR CINTA EXTERIOR
DERECHA IZQUIERDA
Modificaciones 1 2 3 4
Tratamiento
Fecha Nombre
Plano 2 de 9
Dibujado Tuesday, April 12, 2005 Ramón
S3
P3
PARO
BLANCO-ROSA 14 13
21 X6
B-70
70
R1
RELE SCHRACK (ZT5700024)
28
B-64
64 27
13
7
R1 R-C 26
ENVASADORA
380V 25 DERECHA
B-70
70
14
11
5 X4
S. A ENVASADORA
27 X6
S. DE ENVASADORA
R2
RELE SCHRACK (ZT5700024)
38
B-64
64 37
13
7
R2 R-C 36
ENVASADORA
380V 35 IZQUIERDA
B-70
70
14
11
6 X4
S. A ENVASADORA
28 X6
S. DE ENVASADORA
15 X6
19 19
+ IA12DSN04NO
23 X6
18 18
S E5 SINCRONISMO
27 X6
14 14
- 18
19
+ IA12DSN04NO
22 X6
17 17
S E4 ORIGEN
14
- 17
12
15 X5 D3
16 X5
1N4007 A DELGA SOPORTE DETECTORES
14 X5 MONTADO EN
13 X5 PLATO
CARROUSEL
1 X6
Modificaciones 1 2 3 4
B-70
Tratamiento
Fecha Nombre
Plano 3 de 9
Dibujado Ramón
70 Monday, February 19, 2001
21
CARROUSEL COMPUERTA
PRODUCTO DERECHA IZQUIERDA
S1
64
A1
21
A1
A1
A1
22
C2 C5 C6 S3
C1 EV1 P3
PARO
96 A2
96 A2
96 A2
96 A2
22
31 X4
16 X4
15 X4
14 X4
13 X4
21
13 95
95
95
95
26 X4 S5
9 X4
14
27 X4
1 X4
2 X4
13
13
3X4
4X4
S2
C0
V1 V2 V3 MARCHA
14
14
L1
L2
L3
TIERRA
L1
L2
L3
TIERRA
L1
L2
L3
TIERRA
P2
20X4 S1 S1 S1
21X4 S2 S2 S2
22X4 S3 S3 S3 64
23X4 S4 S4 S4
S5 S5 S5
SC VARIADOR YASKAWA SC VARIADOR YASKAWA SC VARIADOR YASKAWA
TIERRA
TIERRA
A1
70 70 70 C0
T1
T2
T3
T1
T2
T3
T1
T2
T3
13 X6 80
A2
CINTA CINTA SAL.1 CINTA SAL. 2
ALIMENTACION DERECHA IZQUIERDA "VALIDA"
25 X4
24 v
16 x6
Modificaciones 1 2 3 4
Tratamiento
24V 3W Fecha Nombre
28 X4 1 2 Plano 4 de 9
Dibujado Tuesday, April 12, 2005 Ramón
PIL. ALARMA Clave
Calcado Peso Numero de plano
24V 3W PESADORA ASOCIATIVA E-43-13-0400E
1 2 Revisado Monday, August 01, 2005 Oscar
12 X4
PIL. MARCHA Escala Modelo Cantidad Sustituye
13 X5
14 X5
15 X5
16 X5
A1
A1
A1
A1
A1
E1 E2 E3 E4 E5
A2
A2
A2
A2
A2
1
1 X5
2
2 X5
3
3 X5
4
4 X5
5
5 X5
A1
A1
A1
A1
A1
E6 E7 E8 E9 E10
A2
A2
A2
A2
A2
6
6 X5
7
7 X5
8
8 X5
9
9 X5
10
10 X5
MANGUERA ELECTROIMANES
Modificaciones 1 2 3 4
Tratamiento
Fecha Nombre
CI-9092 Plano 5 de 9
Dibujado Thursday, October 11, 2001 Ramón
51V 4W
80
11
16 X6 80
10
18 X6 70 PA18CSD04NASA
+
70 S PRODUCTO EN
E7
1 L
1 ELEVADOR
26 X6 1 - FOT14
+ PA18CSD04NASA
25 X6
2
2 S PRODUCTO EN
E8
L
2 CINTA
- FOT14
ALIMENTACION
+
24 X6
3
3 S E6 IA30DSN15NO
- 3 CUBETA ABIERTA
9 X4 7
8
3X4 8
9
4X4 9 EV 1
64
COMPUERTA
4
27 X4
13
5 SELECTOR
95 C2 ELEVADOR
ON/OFF
14
Modificaciones 1 2 3 4
Tratamiento
Fecha Nombre
Plano 6 de 9
Dibujado Tuesday, September 07, 2004 Ramón
-
-
+
+
d6 s1 s1
x6.13 d7 s2 x2.14 x1.14 s2
x6.14 ba1 X6 DISPLAY s3 x2.15 x1.15 s3
x6.15 r/w s4 x2.16 x1.16 s4
BASE x6.16 e vma x2.17 x1.17 vma
( 230 V AC) OMRON x6.17 cs s5 x2.18 x1.18 s5
x6.18 rst X2 s6 x2.19 x1.19 s6
x6.19 x2.20 x1.20
x6.20
gnd BUS I/O e
x2.21 x1.21
e
gnd bas bas
dtack x2.22 x1.22 dtack
DIP 20 watch x2.23 x1.23 watch
x2.24 x1.24
GND
r/w r/w
d7 x2.25 x1.25 d7
N
DIP 34
L
d6 x2.26 x1.26 d6
x7.1 in1 d5 x2.27 x1.27 d5
S8VS-03024 x7.2 in2 d4 x2.28 x1.28 d4
x7.3 in3 d3 x2.29 x1.29 d3
x7.4 in4 d2 x2.30 x1.30 d2 SALIDAS[1..32] X4[1..32]
x7.5 q1 d1 x2.31 x1.31 d1
x7.6 q2 d0 x2.32 x1.32 d0
x7.7 q3 X7 gnd x2.33 x1.33 gnd WEID 2 X 16
x7.8 x2.34 x1.34
x7.9
q4 TECLADO DIP 34
gnd gnd
q5
x7.10 q6
x7.11 q7
x7.12 q8
x7.13 nc
x7.14 gnd
x7.15 vcc X8
X8.1
FA-6Z POSTE 10 BUCLE CORR.
+B
X8.2
0B
Rx X8.3
Tx X8.4
N.C. X8.5 CONECTOR X3
T-511 WEID 5 TRANSFORMADOR
WEID 8 X3.1 24 P
KITAGAWA 11 x1.1 X3.2
11a 0P
x1.2 0a X3.3 19 SA
x1.3 11a X1 TRANSFORMADOR X3.4 0
PASADOS CON UNA VUELTA
CABLES LINEAS FASES
GND
GND
RTS
CTS
RTS
CTS
11
RX
RX
TX
TX
+V
S+
0V
S-
-V
0
X11.1
X11.2
X11.3
X11.4
X11.5
X10.3
X10.5
X10.7
X10.8
x10.2
X9.2
X9.3
X9.5
X9.7
X9.8
36 SA1
0 36 SA1
0 SA
24 OP
0 OP
24 P
19 SA
0P
200
230
0
245 0 0P
FERRITA KITAGAWA
PANTALLA TACTIL
0 SA1 0
7
28 24 P
3
2
COM 2
0 4 DB25
5
36
36 SA1
20 azul+verde v+
0 SA 0 negro+amarillo v-
0 0 OP blanco s-
rojo s+
malla blindaje
19 SA 19 20 24 OP CELULA DE CARGA
Modificaciones 1 2 3 4
Tratamiento
Fecha Nombre
Plano 7 de 9
Dibujado Monday, February 19, 2001 Ramón
+24V 1
GND 2
GND
DSR
DTR
RTS
CTS
RTS
CTS
Rx
Rx
Tx
Tx
P1 P2
P4
20
FICHA
2
3
5
7
8
2
3
4
5
6
7
14 13 21x6 14 13 70 70 14 13 19x6
DB25M
RX
TX
GND
20x6 14 13 70 21 22 21 64 64 22 21 60
a (X9) U1
FICHA 2 12x4 16x6 28x4
3
DB9 H 5
PULSADOR
EAO DIFUSOR EAO DIFUSOR TIPO SETA
GND PANTALLA
VERDE ROJO
24V PANTALLA
PILOTO ( MARCHA ) PILOTO (ALARMA)
LAM. 24V LAM. 24V
(A1 C0)
20X6
12X4
16 X6
B-21 21
21X6
28X4
16 X4
CABLEADO A 17X6
31 X4
CUADRO 19X6
ELECTRICO
CABLEADO A
CUADRO Modificaciones 1 2 3 4
ELECTRONICO
Tratamiento
Fecha Nombre
Plano 8 de 9
Dibujado Thursday, July 27, 2000 Ramón
Modificaciones 1 2 3 4
Tratamiento
Fecha Nombre
Plano 9 de 9
Dibujado Thursday, July 27, 2000 Ramón
32
16
ENTRADAS
TRAFO
8
X1
X2
SCHUKO
X6
1 (MACHO)
17
BUCLE
CORRIENTE
CI-9030-A CI-9092
1
ALIMENTACION
5
S8VS-03024
FUENTE
X 10
1 (MACHO)
RS-232
COM 2
9
TRAFO
X3
X9
1 (MACHO)
8
RS-232
TRAFO
COM 1
T-511
1 17
32
1 5 1 5 1 5
16
1
16
( SIN USO ) ( SIN USO )
Modificaciones 1 2 3 4
Tratamiento
Fecha Nombre
Plano 1 de 1
Dibujado Friday, May 28, 1999 Ramón
TIERRA TIERRA
FILTRO RED
FA-6Z
RC 380 X 3
KITAGAWA
LP1K 0910BD
13 13
LP1K 0610BD
14 14
LR 2K.030X LR 2K.030X
LR 2K 0306 LR 2K 0308
U45
2T1
4T2
6T3
2T1
4T2
6T3
L1
L2
L3
TIERRA
S1
S2
F1 F2 S3
S4
S5
SC VARIADOR YASKAWA
CIMR-J7AZB0P2
TIERRA
L1 L2 L3 N
5A 5A
T1
T2
T3
PUENTE
MANGUERA DE
TIERRA
Modificaciones 1 2 3 4
230V A CUADRO
ELECTRONICO Tratamiento
Fecha Nombre
Plano 1 de 9
Dibujado Thursday, March 16, 2000 Ramón
L1 L2 L3 N
Calcado Peso Clave Numero de plano
PESADORA ASOCIATIVA E-43-10-0100
Revisado Monday, August 01, 2005 Oscar
S L2
T L3
5
C3 C4 C5 C6 C7 C8
RC 380 X 3
RC 380 X 3
RC 380 X 3
RC 380 X 3
RC 380 X 3
RC 380 X 3
21 21 21 21 21 21
22 22 22 22 22 22
4T2
6T3
2T1
4T2
6T3
2T1
4T2
6T3
2T1
4T2
6T3
2T1
4T2
6T3
2T1
4T2
6T3
LR 2K 0306 LR 2K 0306 LR 2K 0306 LR 2K 0306 LR 2K 0306 LR 2K 0306
M M M M M M
MOTOR 0,25 C.V. MOTOR 0,25 C.V. MOTOR 0,25 C.V. MOTOR 0,25 C.V. MOTOR 0,25 C.V. MOTOR 0,25 C.V.
CINTA SAL.1 ( DERECHA ) CINTA SAL. 2 ( IZQUIERDA ) CINTA EXTERIOR CINTA EXTERIOR CINTA CAIDA CINTA CAIDA
DERECHA IZQUIERDA PRODUCTO 1 PRODUCTO 2
Modificaciones 1 2 3 4
Tratamiento
Fecha Nombre
Plano de
Dibujado Thursday, March 16, 2000 2 9
Ramón
S3
P3
PARO
BLANCO-ROSA 14 13
21 X6
B-70
70
R1
RELE SCHRACK (ZT5700024)
28
B-64
64 27
13
7
R1 R-C 26
ENVASADORA
380V 25 DERECHA
B-70
70
14
11
5 X4
S. A ENVASADORA
27 X6
S. DE ENVASADORA
R2
RELE SCHRACK (ZT5700024)
38
B-64
64 37
13
7
R2 R-C 36
ENVASADORA
380V 35 IZQUIERDA
B-70
70
14
11
6 X4
S. A ENVASADORA
28 X6
S. DE ENVASADORA
15 X6
19 19
+ IA12DSN04NO
23 X6
18 18
S E5 SINCRONISMO
27 X6
14 14
- 18
19
+ IA12DSN04NO
22 X6
17 17
S E4 ORIGEN
14
- 17
12
15 X5 D3
16 X5
1N4007 A DELGA SOPORTE DETECTORES
14 X5 MONTADO EN
13 X5 PLATO
CARROUSEL
1 X6
Modificaciones 1 2 3 4
B-70
Tratamiento
Fecha Nombre
Plano 3 de 9
Dibujado Ramón
70 Monday, February 19, 2001
21
CINTA CAIDA CINTA CAIDA CARROUSEL ELEVADOR SAL.1 2 EXTERIOR EXTERIOR
S1 PRODUCTO 1 PRODUCTO 2 PRODUCTO DERECHA IZQUIERDA DERECHA IZQUIERDA
A1
64
21
A1
A1
A1
A1
A1
A1
A1
22
C2 C3 C4 C5 C6 S3
C7 C8 C1 EV1 P3
PARO
96 A2
96 A2
96 A2
96 A2
96 A2
96 A2
96 A2
96 A2
22
31 X4
16 X4
15 X4
14 X4
13 X4
21
13 95
95
95
95
95
95
95
95
26 X4 S5
9 X4
14
27 X4
1 X4
2 X4
13
13
3X4
4X4
S2
C0
V1 MARCHA
14
14
L1
L2
L3
TIERRA
P2
20X4 S1
21X4 S2
22X4 S3
23X4 S4 64
S5 MOTOR CINTA
SC VARIADOR YASKAWA ALIMENTACION
CIMR-J7AZB0P2
TIERRA
A1
C0
T1
T2
T3
70
13 X6 80
A2
"VALIDA"
25 X4
24 v
16 x6
Modificaciones 1 2 3 4
Tratamiento
24V 3W Fecha Nombre
28 X4 1 2 Plano 4 de 9
Dibujado Tuesday, February 20, 2001 Ramón
PIL. ALARMA Clave
Calcado Peso Numero de plano
24V 3W PESADORA ASOCIATIVA E-432-10-0400E
1 2 Revisado Monday, August 01, 2005 Oscar
12 X4
PIL. MARCHA Escala Modelo Cantidad Sustituye
13 X5
14 X5
15 X5
16 X5
A1
A1
A1
A1
A1
E1 E2 E3 E4 E5
A2
A2
A2
A2
A2
1
1 X5
2
2 X5
3
3 X5
4
4 X5
5
5 X5
A1
A1
A1
A1
A1
E6 E7 E8 E9 E10
A2
A2
A2
A2
A2
6
6 X5
7
7 X5
8
8 X5
9
9 X5
10
10 X5
MANGUERA ELECTROIMANES
Modificaciones 1 2 3 4
Tratamiento
Fecha Nombre
CI-9092 Plano 5 de 9
Dibujado Thursday, October 11, 2001 Ramón
51V 4W
80
11
16 X6 80
10
18 X6 70 PA18CSD04NASA
+
70 S PRODUCTO EN
E7
1 L
1 ELEVADOR
26 X6 1 - FOT14
+ PA18CSD04NASA
25 X6
2
2 S PRODUCTO EN
E8
L
2 CINTA
- FOT14
ALIMENTACION
+
24 X6
3
3 S E6 IA30DSN15NO
- 3 CUBETA ABIERTA
9 X4 7
8
3X4 8
9
4X4 9 EV 1
64
COMPUERTA
4
27 X4
13
5 SELECTOR
95 C2 ELEVADOR
ON/OFF
14
Modificaciones 1 2 3 4
Tratamiento
Fecha Nombre
Plano 6 de 9
Dibujado Tuesday, September 07, 2004 Ramón
-
-
+
+
d6 s1 s1
x6.13 d7 s2 x2.14 x1.14 s2
x6.14 ba1 X6 DISPLAY s3 x2.15 x1.15 s3
x6.15 r/w s4 x2.16 x1.16 s4
BASE x6.16 e vma x2.17 x1.17 vma
( 230 V AC) OMRON x6.17 cs s5 x2.18 x1.18 s5
x6.18 rst X2 s6 x2.19 x1.19 s6
x6.19 x2.20 x1.20
x6.20
gnd BUS I/O e
x2.21 x1.21
e
gnd bas bas
dtack x2.22 x1.22 dtack
DIP 20 watch x2.23 x1.23 watch
x2.24 x1.24
GND
r/w r/w
d7 x2.25 x1.25 d7
N
DIP 34
L
d6 x2.26 x1.26 d6
x7.1 in1 d5 x2.27 x1.27 d5
S8VS-03024 x7.2 in2 d4 x2.28 x1.28 d4
x7.3 in3 d3 x2.29 x1.29 d3
x7.4 in4 d2 x2.30 x1.30 d2 SALIDAS[1..32] X4[1..32]
x7.5 q1 d1 x2.31 x1.31 d1
x7.6 q2 d0 x2.32 x1.32 d0
x7.7 q3 X7 gnd x2.33 x1.33 gnd WEID 2 X 16
x7.8 x2.34 x1.34
x7.9
q4 TECLADO DIP 34
gnd gnd
q5
x7.10 q6
x7.11 q7
x7.12 q8
x7.13 nc
x7.14 gnd
x7.15 vcc X8
X8.1
FA-6Z POSTE 10 BUCLE CORR.
+B
X8.2
0B
Rx X8.3
Tx X8.4
N.C. X8.5 CONECTOR X3
T-511 WEID 5 TRANSFORMADOR
WEID 8 X3.1 24 P
KITAGAWA 11 x1.1 X3.2
11a 0P
x1.2 0a X3.3 19 SA
x1.3 11a X1 TRANSFORMADOR X3.4 0
PASADOS CON UNA VUELTA
CABLES LINEAS FASES
GND
GND
RTS
CTS
RTS
CTS
11
RX
RX
TX
TX
+V
S+
0V
S-
-V
0
X11.1
X11.2
X11.3
X11.4
X11.5
X10.3
X10.5
X10.7
X10.8
x10.2
X9.2
X9.3
X9.5
X9.7
X9.8
36 SA1
0 36 SA1
0 SA
24 OP
0 OP
24 P
19 SA
0P
200
230
0
245 0 0P
FERRITA KITAGAWA
PANTALLA TACTIL
0 SA1 0
verde 7
28 24 P
amarillo
gris
3
2
COM 2
0 4 DB25
5
36
36 SA1
20 azul+verde v+
0 SA 0 negro+amarillo v-
0 0 OP blanco s-
rojo s+
malla blindaje
19 SA 19 20 24 OP CELULA DE CARGA
Modificaciones 1 2 3 4
Tratamiento
Fecha Nombre
Plano 7 de 9
Dibujado Monday, February 19, 2001 Ramón
A3 ESQUEMA BLOQUES
PA-43 S
Sustituido
FUJI UG-22-HI-CS
+24V 1
GND 2
GND
DSR
DTR
RTS
CTS
RTS
CTS
Rx
Rx
Tx
Tx
P1 P2
P4
20
FICHA
2
3
5
7
8
2
3
4
5
6
7
14 13 21x6 14 13 70 70 14 13 19x6
DB25M
RX
TX
GND
20x6 14 13 70 21 22 21 64 64 22 21 60
a (X9) U1
FICHA 2 12x4 16x6 28x4
3
DB9 H 5
PULSADOR
EAO DIFUSOR EAO DIFUSOR TIPO SETA
GND PANTALLA
VERDE ROJO
24V PANTALLA
PILOTO ( MARCHA ) PILOTO (ALARMA)
LAM. 24V LAM. 24V
(A1 C0)
20X6
12X4
16 X6
B-21 21
21X6
28X4
16 X4
CABLEADO A 17X6
31 X4
CUADRO 19X6
ELECTRICO
CABLEADO A
CUADRO Modificaciones 1 2 3 4
ELECTRONICO
Tratamiento
Fecha Nombre
Plano 8 de 9
Dibujado Thursday, July 27, 2000 Ramón
Modificaciones 1 2 3 4
Tratamiento
Fecha Nombre
Plano 9 de 9
Dibujado Thursday, July 27, 2000 Ramón
32
16
ENTRADAS
TRAFO
8
X1
X2
SCHUKO
X6
1 (MACHO)
17
BUCLE
CI-9030-A CI-9092
ALIMENTACION
CORRIENTE
1
S8VS-03024
5
FUENTE
X 10
1 (MACHO)
RS-232
COM 2
9
TRAFO
X3
X9
1 (MACHO)
8
RS-232
TRAFO
COM 1
T-511
1 17
32
1 5 1 5 1 5
16
1
16
( SIN USO ) ( SIN USO )
Modificaciones 1 2 3 4
Tratamiento
Fecha Nombre
Plano 1 de 1
Dibujado Friday, May 28, 1999 Ramón
TIERRA TIERRA
FILTRO RED
FA-6Z
RC 380 X 3
KITAGAWA
LP1K 0910BD
13 13
LP1K 0610BD
14 14
LR 2K.030X LR 2K.030X
LR 2K 0306 LR 2K 0308
U45
2T1
4T2
6T3
2T1
4T2
6T3
L1
L2
L3
TIERRA
S1
S2
F1 F2 S3
S4
S5
SC VARIADOR YASKAWA
CIMR-J7AZB0P2
TIERRA
L1 L2 L3 N
5A 5A
T1
T2
T3
PUENTE
MANGUERA DE
TIERRA
Modificaciones 1 2 3 4
230V A CUADRO
ELECTRONICO Tratamiento
Fecha Nombre
Plano 1 de 9
Dibujado Thursday, March 16, 2000 Ramón
L1 L2 L3 N
Calcado Peso Clave Numero de plano
PESADORA ASOCIATIVA E-43-11-0100E
Revisado Monday, August 01, 2005 Oscar
A TOMA DE RED Modelo
Escala Cantidad Sustituye
ELECTRICA
CUADRO ELECTRICO 1/2
PA-43 V
Sustituido
TRIFAS. 380V
L1 R
L2 S
L3 T
5
C3 C4 C5 C6
21 21 21 21
4T2
6T3
2T1
4T2
6T3
2T1
4T2
6T3
2T1
4T2
6T3
LR 2K 0306 LR 2K 0306 LR 2K 0306 LR 2K 0306
BORNAS REGLETERO
M M M M
MOTOR 0,25 C.V. MOTOR 0,25 C.V. MOTOR 0,25 C.V. MOTOR 0,25 C.V.
CINTA SAL.1 ( DERECHA ) CINTA SAL. 2 ( IZQUIERDA ) CINTA EXTERIOR CINTA EXTERIOR
DERECHA IZQUIERDA
Modificaciones 1 2 3 4
Tratamiento
Fecha Nombre
Plano de
Dibujado Thursday, March 16, 2000 2 9
Ramón
S3
P3
PARO
BLANCO-ROSA 14 13
21 X6
B-70
70
R1
RELE SCHRACK (ZT5700024)
28
B-64
64 27
13
7
R1 R-C 26
ENVASADORA
380V 25 DERECHA
B-70
70
14
11
5 X4
S. A ENVASADORA
27 X6
S. DE ENVASADORA
R2
RELE SCHRACK (ZT5700024)
38
B-64
64 37
13
7
R2 R-C 36
ENVASADORA
380V 35 IZQUIERDA
B-70
70
14
11
6 X4
S. A ENVASADORA
28 X6
S. DE ENVASADORA
15 X6
19 19
+ IA12DSN04NO
23 X6
18 18
S E5 SINCRONISMO
27 X6
14 14
- 18
19
+ IA12DSN04NO
22 X6
17 17
S E4 ORIGEN
14
- 17
12
15 X5 D3
16 X5
1N4007 A DELGA SOPORTE DETECTORES
14 X5 MONTADO EN
13 X5 PLATO
CARROUSEL
1 X6
Modificaciones 1 2 3 4
B-70
Tratamiento
Fecha Nombre
Plano 3 de 9
Dibujado Ramón
70 Monday, February 19, 2001
21
CARROUSEL COMPUERTA
PRODUCTO DERECHA IZQUIERDA
S1
64
A1
21
A1
A1
A1
A1
A1
22
C2 C3 C4 C5 C6 S3
C1 EV1 P3
PARO
96 A2
96 A2
96 A2
96 A2
96 A2
96 A2
22
31 X4
16 X4
15 X4
14 X4
13 X4
21
13 95
95
95
95
95
95
26 X4 S5
9 X4
14
27 X4
1 X4
2 X4
13
13
3X4
4X4
S2
C0
V1 MARCHA
14
14
L1
L2
L3
TIERRA
P2
20X4 S1
21X4 S2
22X4 S3
23X4 S4 64
S5 MOTOR CINTA
SC VARIADOR YASKAWA ALIMENTACION
CIMR-J7AZB0P2
TIERRA
A1
C0
T1
T2
T3
70
13 X6 80
A2
"VALIDA"
25 X4
24 v
16 x6
Modificaciones 1 2 3 4
Tratamiento
24V 3W Fecha Nombre
28 X4 1 2 Plano 4 de 9
Dibujado Tuesday, February 20, 2001 Ramón
PIL. ALARMA Clave
Calcado Peso Numero de plano
24V 3W PESADORA ASOCIATIVA
1 2 Revisado Monday, August 01, 2005 Oscar E-43-11-0400E
12 X4
PIL. MARCHA Escala Modelo Cantidad Sustituye
13 X5
14 X5
15 X5
16 X5
A1
A1
A1
A1
A1
E1 E2 E3 E4 E5
A2
A2
A2
A2
A2
1
1 X5
2
2 X5
3
3 X5
4
4 X5
5
5 X5
A1
A1
A1
A1
A1
E6 E7 E8 E9 E10
A2
A2
A2
A2
A2
6
6 X5
7
7 X5
8
8 X5
9
9 X5
10
10 X5
MANGUERA ELECTROIMANES
Modificaciones 1 2 3 4
Tratamiento
Fecha Nombre
CI-9092 Plano 5 de 9
Dibujado Thursday, October 11, 2001 Ramón
51V 4W
80
11
16 X6 80
10
18 X6 70 PA18CSD04NASA
+
70 S PRODUCTO EN
E7
1 L
1 ELEVADOR
26 X6 1 - FOT14
+ PA18CSD04NASA
25 X6
2
2 S PRODUCTO EN
E8
L
2 CINTA
- FOT14
ALIMENTACION
+
24 X6
3
3 S E6 IA30DSN15NO
- 3 CUBETA ABIERTA
9 X4 7
8
3X4 8
9
4X4 9 EV 1
64
COMPUERTA
4
27 X4
13
5 SELECTOR
95 C2 ELEVADOR
ON/OFF
14
Modificaciones 1 2 3 4
Tratamiento
Fecha Nombre
Plano 6 de 9
Dibujado Tuesday, September 07, 2004 Ramón
-
-
+
+
d6 s1 s1
x6.13 d7 s2 x2.14 x1.14 s2
x6.14 ba1 X6 DISPLAY s3 x2.15 x1.15 s3
x6.15 r/w s4 x2.16 x1.16 s4
BASE x6.16 e vma x2.17 x1.17 vma
( 230 V AC) OMRON x6.17 cs s5 x2.18 x1.18 s5
x6.18 rst X2 s6 x2.19 x1.19 s6
x6.19 x2.20 x1.20
x6.20
gnd BUS I/O e
x2.21 x1.21
e
gnd bas bas
dtack x2.22 x1.22 dtack
DIP 20 watch x2.23 x1.23 watch
x2.24 x1.24
GND
r/w r/w
d7 x2.25 x1.25 d7
N
DIP 34
L
d6 x2.26 x1.26 d6
x7.1 in1 d5 x2.27 x1.27 d5
S8VS-03024 x7.2 in2 d4 x2.28 x1.28 d4
x7.3 in3 d3 x2.29 x1.29 d3
x7.4 in4 d2 x2.30 x1.30 d2 SALIDAS[1..32] X4[1..32]
x7.5 q1 d1 x2.31 x1.31 d1
x7.6 q2 d0 x2.32 x1.32 d0
x7.7 q3 X7 gnd x2.33 x1.33 gnd WEID 2 X 16
x7.8 x2.34 x1.34
x7.9
q4 TECLADO DIP 34
gnd gnd
q5
x7.10 q6
x7.11 q7
x7.12 q8
x7.13 nc
x7.14 gnd
x7.15 vcc X8
X8.1
FA-6Z POSTE 10 BUCLE CORR.
+B
X8.2
0B
Rx X8.3
Tx X8.4
N.C. X8.5 CONECTOR X3
T-511 WEID 5 TRANSFORMADOR
WEID 8 X3.1 24 P
KITAGAWA 11 x1.1 X3.2
11a 0P
x1.2 0a X3.3 19 SA
x1.3 11a X1 TRANSFORMADOR X3.4 0
PASADOS CON UNA VUELTA
CABLES LINEAS FASES
GND
GND
RTS
CTS
RTS
CTS
11
RX
RX
TX
TX
+V
S+
0V
S-
-V
0
X11.1
X11.2
X11.3
X11.4
X11.5
X10.3
X10.5
X10.7
X10.8
x10.2
X9.2
X9.3
X9.5
X9.7
X9.8
36 SA1
0 36 SA1
0 SA
24 OP
0 OP
24 P
19 SA
0P
200
230
0
245 0 0P
FERRITA KITAGAWA
PANTALLA TACTIL
0 SA1 0
verde 7
28 24 P
amarillo
gris
3
2
COM 2
0 4 DB25
5
36
36 SA1
20 azul+verde v+
0 SA 0 negro+amarillo v-
0 0 OP blanco s-
rojo s+
malla blindaje
19 SA 19 20 24 OP CELULA DE CARGA
Modificaciones 1 2 3 4
Tratamiento
Fecha Nombre
Plano 7 de 9
Dibujado Monday, February 19, 2001 Ramón
A3 ESQUEMA BLOQUES
PA-43 V
Sustituido
FUJI UG-22-HI-CS
+24V 1
GND 2
GND
DSR
DTR
RTS
CTS
RTS
CTS
Rx
Rx
Tx
Tx
P1 P2
P4
20
FICHA
2
3
5
7
8
2
3
4
5
6
7
14 13 21x6 14 13 70 70 14 13 19x6
DB25M
RX
TX
GND
20x6 14 13 70 21 22 21 64 64 22 21 60
a (X9) U1
FICHA 2 GRIS 12x4 16x6 28x4
3 AMARILLO
DB9 H 5 VERDE
PULSADOR
EAO DIFUSOR EAO DIFUSOR TIPO SETA
GND PANTALLA
VERDE ROJO
24V PANTALLA
PILOTO ( MARCHA ) PILOTO (ALARMA)
LAM. 24V LAM. 24V
(A1 C0)
20X6
12X4
16 X6
B-21 21
21X6
28X4
16 X4
CABLEADO A 17X6
31 X4
CUADRO 19X6
ELECTRICO
CABLEADO A
CUADRO Modificaciones 1 2 3 4
ELECTRONICO
Tratamiento
Fecha Nombre
Plano 8 de 9
Dibujado Thursday, July 27, 2000 Ramón
A4 CUADRO DE MANDO
PA-43 V Sustituido
A2 RELE 2 1 1 6 x4
B-35 2 2 28 X6
3 3
B-64 4 4 64 (14X4)
B-70 5 5 70 (1X6)
A2 C0 6 6 25X4
A2 C1 (95 TERMICO) 7 7 26X4
A2 RELE 1 8 MANGUERA INTERCONEXION 8 5X4
BORNA 25 (ENVASADORA) 9 9 27X6
B-80 10 CUADRO ELECTRICO 10 13 X6
A CUADRO A2 C3 11 A CUADRO ELECTRONICO 11 1 X4 a CUADRO
A2 C4 12 12 2 X4
ELECTRICO A2 C5 13 13 3 X4 ELECTRONICO
A2 C6 14 14 4 X4
S1 V1 15 15 20 X4
S3 V1 16 16 21 X4
S4 V1 17 17 22 X4
S5 V1 18 18 23 X4
Modificaciones 1 2 3 4
Tratamiento
Fecha Nombre
Plano 9 de 9
Dibujado Thursday, July 27, 2000 Ramón
32
16
ENTRADAS
TRAFO
8
X1
X2
SCHUKO
X6
1 (MACHO)
17
BUCLE
CORRIENTE
CI-9030-A CI-9092
1
ALIMENTACION
5
S8VS-03024
FUENTE
X 10
1 (MACHO)
RS-232
COM 2
9
TRAFO
X3
X9
1 (MACHO)
8
RS-232
TRAFO
COM 1
T-511
1 17
32
1 5 1 5 1 5
16
1
16
( SIN USO ) ( SIN USO )
Modificaciones 1 2 3 4
Tratamiento
Fecha Nombre
Plano 1 de 1
Dibujado Friday, May 28, 1999 Ramón