Why dissipation/power factor and capacitance? Early loss detection improves performance
The condition of insulation is essential for secure and Variations in the dissipation/power factor are often signs of
reliable operation of high-voltage (HV) electrical equip- mechanical displacements, the ingress of moisture, partial
ment. Measuring dissipation/power factor (Tan Delta) discharge, aging and degradation in insulation.
and capacitance helps you to determine overall insulation By detecting these conditions early, corrective action can
condition of: be taken to improve the performance and reliability of
> Rotating machines (motors and generators) electrical equipment.
> High-voltage cables and cable accessories Our TANDO 700 system provides you with a precise and
> Distribution, instrument and power transformers extremely safe measuring solution that makes insulation
> Bushings tests easier and more reliable. It can be used for insulation
material tests in research labs as well as production quality
> Capacitors
checks in factory HV test fields.
> Circuit breakers
High-voltage area
Additional measurements
TANDO 700 also measures power, voltage, current, impe-
dance and frequency. All measurement data is displayed
and analyzed in real time. The modular system can also be
used with our MPD 600 for simultaneous measurement
and analysis of partial discharges.
Safe area
TANDO 700
www.omicron.at/tando700
3
Customizable data display and reporting
4
Scope view FFT view
Graph of real-time input signals from the measuring units Fast Fourier Transformation (FFT) detects interference
> Visualizes quality of incoming input signals > FFT graph displays signal-to-noise ratio of input signals
> Data export for reports in BMP, PNG or JPG formats > Signal status is updated continuously
5
Ordering information
Software
1 × TANDO 700 software and documentation CD
(Computer not included)
Documentation
1 × TANDO 700 calibration report
1 × TANDO 700 getting started guide
6
Technical specifications
Dissipation/ < 5 x 10 -6
0.1 % rdg. + 2 x 10 -5
5 μA ≤ IIN ≤ 1 A Dimensions (W x D x H) 115 x 175 x 55 mm
power factor (4.53 x 6.88 x 2.16 in.)
System package weight < 5 kg / 11.36 lbs
Capacitance 0.005 % 0.05 % rdg. + 0.05 pF 5 μA ≤ IIN ≤ 1 A
(without accessories)
Current < 0.02 % 0.05 % rdg. + 0.05 nA 5 μA ≤ IIN ≤ 1 A
Connections Front:
Voltage < 0.02 % 0.2 % rdg. + 1 V 10 pF ≤ CRef ≤ 10 nF 2 x Standard connectors for fiber
optic network
1
The specified accuracies are valid for the frequency of the test voltage at 50/60 Hz, a
1 x 4 pin DC input socket,
temperature range of 23 °C ± 5 °C, SINAD of the power source < 12 dB and without errors
LEMO FFA
depending on CREF, input combination and parasitic capacitances.
Rear:
2
Without a connected shunt and running the software in Auto Mode.
2 x 4 mm banana red/black plug
For detailed range dispersion and pre-conditions for accuracy values, please 1 x 4 pin shunt socket, LEMO FGG
contact OMICRON Support. he calculated value
Environmental Conditions
System Data Characteristic Rating
Frequency Range 5 Hz ... 400 Hz Operating temperature -10 °C … +50 °C
Direct and internal shunt input ranges -14 °F … +122 °F
Storage temperature -20 °C … +60 °C
1.2 mA Impedance 17 Ω
-4 °F … +140 °F
Current 0.5 μA … 1.2 mA
Charging temperature 0 °C … +40 °C
200 mA Impedance 50 Ω 32 °F … +104 °F
Current 1 mA … 200 mA Humidity -5 % … 85 % (non-condensing)
1A Impedance 5.4 Ω
SHT1 External Shunts
Current 10 mA … 1 A
Parameter Value
Connection to MCU1
Maximum current 4A 15 A 28 A
Fiber optic Wave length 1300 nm
Minimum current 100 mA 1A 3A
Mode Multimode 50 / 125 μm
Nominal resistance 500 mΩ 50 mΩ 15 mΩ
Fiber length Up to 2 km
Typical temperature coefficient 2 ppm 2 ppm 2 ppm
Computer Requirements Initial resistance accuracy ±0.04 %
Characteristic Required Absolute phase deviation tan δ < 2 x 10 -5
Processor Intel Pentium 4 (≥ 2.5 GHz), Pentium M Weight 0.68 kg / 1.49 lbs
(≥ 1.5 GHz), Core, Core 2 processor or
AMD Athlon 64 or Turion 64 processor CE Conformity
(EMC) Directive 2004/108/EC, (LVD) low-voltage directive 2006/95/EC
Memory 1GB RAM, USB 2.0 Hi-speed compatible
EMC EN 61326-1/2013 Emission: Class A
Immunity: Table 2
Operating system Microsoft Windows XP (32 Bit),
Safety UN 38.3
Windows 7, Windows 8
IEC 62133:2012 (ed.2)
UL 2054 (ed.2, incl. rev. 2011)
Calibration certificates TÜV certificate no. B 14 11 17955 065
Certificate TANDO 700 System Protection IEC 60068- /2-6 / 2-27 / 2-78 Vibration, Shock,
PTB calibration mark 20269 - 20273 PTB 14 Standard Damp Heat
PTB calibration mark 20269 - 20273 PTB 14 Advanced IEC 60529 § 12.2 / § 13.2 IP4X
7
OMICRON is an international company serving the electrical power industry with
innovative testing and diagnostic solutions. The application of OMICRON products
allows users to assess the condition of the primary and secondary equipment on
their systems with complete confidence. Services offered in the area of consulting,
commissioning, testing, diagnosis and training make the product range complete.
Customers in more than 140 countries rely on the company’s ability to supply leading-
edge technology of excellent quality. Service centers on all continents provide a broad
base of knowledge and extraordinary customer support. All of this together with our
strong network of sales partners is what has made our company a market leader in the
electrical power industry.