Calculations are inaccordance with the BS5950: Part 1: 1990 and the analysis follows the recommended
design procedure checks given in the BCSA/SCI publication "Joints in simple Construction" 2nd Edition.
Depth D = = 100 mm
Web Thickness tw = = 6.3 mm
Strength py = = 275 N/mm2
Number of bolts n = = 4
Number of rows bn = = 2
Bolt Diameter db = = 16 mm
Hole Diameter Dh = db+2 = 18 mm
Min. Required Pitch of Bolts pmin = db * 2.5 = 40 mm
Min. Required Edge Distance emin = db * 2.0 = 32 mm
Pitch of Bolt Group (Vertical) p = = 50 mm
Gauge/Pitch of Bolt (Horizontal g = = 180 mm
Edge Distance (Vertical) e1 = = 40 mm
Edge Distance (Horizontal) e2 = = 50 mm
V <= Ps, Applied shear is within plain shear capacity of bolt gr V <= Ps OK!!
F <= Pbt, Maximum load/bolt is within Tension capacity F <= Pbt bolt OK!!
Fr <= Pb, Maximum load/bolt is within bearing capacity of Bolt V <= Pb OK!!
Fr <= Pb, Maximum load/bolt is within bearing capacity of connecting ply V <= Pb OK!!
Shear Capacity of End Plate
V <= Pvp, Applied shear is within plain shear capacity of fin plaV <= Pvp OK!!
V <= Pvb, Applied shear is within block shear capacity of fin pl V <= Pvb OK!!
V <= Pv, Applied hear is within shear capacity of beam web V <= Pv OK!!
Weld Requirement
Try FW size FW = = 6 mm
Design Strength (43 or 51) pw = Table 36, E43 = 215 N/mm2
Weld Capacity pwr = FW * pw = 0.903 kN/mm
Fr <= pwr, the fillet weld provided is satisfactory Fr <= pwr OK!!
Tension Capacity of End Plate
F plate