Documente Academic
Documente Profesional
Documente Cultură
Department of Dental Materials Science, School of Life Dentistry at Tokyo, The Nippon Dental University 1-9-20, Fujimi, Chiyoda-ku, Tokyo 102-
8159, Japan
Corresponding author, Taira MIYASAKA; E-mail: miyasaka@tky.ndu.ac.jp
Contrary to widespread incise CAD/CAM, little is known about the dental application of 3D printing, especially the possibility of
using 3D printing with organic material. The resin patterns of a full crown model were created by four types of 3D printers, a thermo-
fusion device (CX), a digital light processing stereo-lithograph device (B9), a laser stereo-lithograph device (DW) and a multi-jet
modeling device (PJ). The dimensional accuracy of the outer and inner diameters and depths of the created model crowns, and the
surface roughness of sidewall were investigated. The outer diameters were smaller than the designed value in most conditions. The
inner diameters were smaller than the designed value in any enlargement ratio except B9. The depth of CX or B9 tended to become
shallower, though that of PJ or DW tended to increase. The surface roughness along the tooth axis direction was greater than that
perpendicular to the tooth axis.
Minimum stacking
3D printer Code Type Material (lot No.) Manufacturer
pitch (μm)
confirmed. It was clear from the specimen created by in the basal plane of cervical portion was observed in
DW that support was provided to the occlusal plane so the CX-molded specimen, and the lamination of the
that the modeling stage and occlusal surfaces would melting resin filament could be visually confirmed.
not contact directly. Such support was not provided in Because a semi-transparent material was used in
the specimen created by B9 and PJ. The color of the printing with DW, the support given to the occlusal
specimens was different because the materials used in surface could be seen as whitish. With respect to the
this study were different. expansion rates of the specimens created by following
Overall images of the inner ceiling observed from the two-way layout experimental design, whose two
the cervical direction, enlarged pictures of the basal factors were type of 3D printer and the enlargement
plane of the cervical portion, the occlusal (top) surface ratios of the prototype, the mean values and standard
and the outer sidewall of the marginal portion are shown deviations of the ratio of the prototypes inner and outer
in Fig. 3. The gap between the outer and inner sidewall diameters and depths are shown in Table 2.
From the two-way ANOVA of the outer diameter
of the expansion rate (%), which was calculated from
the value of the prototype shown in Fig. 1, significant
differences were found for the type of printer (factor
A), the enlargement ratio (factor B) and the interaction
of the type of printer and the enlargement ratio (A×B)
(p<0.01). The outer diameter became smaller than
the designed value in most conditions, except in some
cases of CX. B9 showed the smallest value of all of the
enlargement ratios. No significant difference (p>0.05)
in the number of supports of CX was observed.
From the two-way ANOVA of the expansion rate
of the inner diameter (%) calculated from the value of
the prototype, significant differences were found for
the type of printer (factor A), the enlargement ratio
(factor B) and the interaction of the type of printer and
the enlargement ratio (A×B) (p<0.01). Generally, each
printer in any enlargement ratio showed a smaller
Fig. 2 Exterior view of the crowns created by the 3D value than the designed one, with the exception of B9.
printers. In particular, the crowns molded by CX were of a much
Fig. 3 Overall images of the inner ceiling observed from the cervical direction, enlarged pictures of the
basal plane of the cervical portion, the inner ceiling surface and the outer sidewall of the marginal
portion of crowns molded by the 3D printers.
Dent Mater J 2016; 35(2): 250–256 253
Table 2 Mean values and standard deviations of the ratio of inner and outer diameters and depths of the prototypes
Outer diameter
CX0 −0.49 (0.04) a 0.92 (0.53) a,b,d 2.47 (0.15) a,b 5.03 (0.50) a
CX1 −0.39 (0.21) a 0.98 (0.52) a,b,d 2.58 (0.14) a,b,c 5.23 (0.41) a
CX2 −0.24 (0.16) a 1.05 (0.46) a,b 3.55 (0.47) b,c 5.18 (0.20) a
B9 −2.82 (0.24) −0.57 (0.55) c,d 1.11 (0.49) d 2.74 (0.13) b
PJ −0.16 (0.45) a 0.49 (0.16) a,b,d 2.56 (0.08) a,b,c 4.42 (0.09) a
DW −0.65 (0.17) a 0.01 (0.07) a,c,d 1.18 (0.10) d 3.33 (0.30) b
Inner diameter
CX0 −2.45 (0.71) a −1.73 (0.52) a,b,c 0.03 (0.16) a 3.17 (0.29) a,b
CX1 −3.02 (0.15) a −1.07 (0.48) a,b 0.36 (0.20) a 3.69 (0.35) a,b,c
CX2 −3.35 (0.08) a −2.59 (0.06) a,c −0.08 (0.35) a 1.31 (0.34)
B9 1.87 (0.55) 2.39 (0.70) 4.44 (0.84) 6.80 (0.48)
PJ −0.30 (0.21) b 0.66 (0.18) d 2.71 (0.41) b 4.91 (0.42) b,c
DW −0.07 (0.03) b 0.75 (0.31) d 1.89 (0.44) b 4.01 (0.17) a,b,c
Depth
CX0 −5.99 (1.13) a −5.64 (0.83) a,b −2.99 (1.03) a −2.24 (0.37) a,c
CX1 −5.21 (0.45) a −3.72 (0.25) a,b,c −2.43 (0.41) a 0.24 (0.45) b,c
CX2 −5.21 (1.51) a −3.61 (0.64) b,c −2.36 (0.39) a −0.54 (1.23) a,b,c
B9 −4.12 (0.38) a −0.45 (0.23) d,f 2.24 (0.35) b 2.81 (0.49)
PJ 0.49 (0.32) b 1.59 (0.24) e,f 3.58 (0.31) b 5.18 (0.55) d
DW 0.43 (0.08) b 1.36 (0.04) d,e,f 3.37 (0.16) b 5.28 (0.33) d
The same superscript letters indicate values with no statistically significant difference (p>0.05).
Table 3 Mean values and standard deviations of the deviation from the designed value of the inner and the outer diameters
and the depth in millimeters
PJ −0.055 (0.035) a
−0.025 (0.030) b
0.046 (0.036) b
The same superscript letters indicate values with no statistically significant difference (p>0.05).
smaller value than the designed crowns. The deviation of the inner and outer diameters and
From the two-way ANOVA for expansion rate of depths from the designed values were easily calculated
depth (%) calculated from the value of the prototype, from the above data. The results indicated significant
significant differences were found for the type of printer differences in factor A, i.e., the type of printer, and the
(factor A), the enlargement ratio (factor B) and the deviations between the measured values of molded
interaction of the type of printer and the enlargement crown and the designed values (n=12) in millimeters
ratio (A×B) (p<0.05). In any enlargement ratio, printing are shown in Table 3. The inner diameters and depths
with CX and B9 showed a tendency to become quite of the crowns created by PJ or DW showed a relatively
shallow, although printing with PJ and DW showed a high precision.
tendency to become slightly greater in depth. The mean values and standard deviations of
254 Dent Mater J 2016; 35(2): 250–256
B9 5.50 (0.76) a
2.80 (0.47) a
The same superscript letters indicate values with no statistically significant difference (p>0.05).
the surface roughness of the crown, formed by the considered that the lamination pitch of 29–32 μm23) is
different types of 3D printers and measured in different relatively large, it exhibited a very smooth appearance.
operating directions, are shown in Table 4. From the The inner and outer diameters of the crown tended
two-way ANOVA of surface roughness, significant to be formed slightly smaller as a whole. The outer
differences were found for the type of printer (factor A), diameter of several crowns molded by CX showed a
the scanning direction (factor B) and the interaction of larger value than the designed value. Because the
the type of printer and the operating direction (A×B) thermo-fusion method consisted of stacking the molten
(p<0.05). As for the type of printer, surface roughness filaments by pushing the molten plastic from a nozzle tip
along the tooth axial direction was greater than the with a diameter of 0.5 mm, the extruded thermoplastic
roughness in a direction horizontal to the tooth, except resin was compressed, leading to the slight swelling of
for that of CX or DW. The surface roughness observed the crown. The inner diameter of the crown formed by
in the crown molded by CX was the largest; the B9 was exceptionally large, and the outer diameter was
roughness observed along the tooth axial direction of considerably smaller than those formed by the other
the crown molded by DW was the smallest, and the printers. This might be due to the adoption of the digital
roughness observed in the crown created by PJ in the light processing (DLP) projector because the focus of
direction horizontal to the tooth axis was the smallest. the illuminating light at an edge became blurred as the
distance from the center of the designed area increased,
DISCUSSION so the edge of the crown tended to remain unpolymerized;
therefore, when viewed from the entire modeling
The patent of thermo-fusion technology for 3D printers area, the molded crown grew thinner. In general, as
expired in 2009, and low-cost thermo-fusion 3D printers for the printer using the laser stereo-lithograph or
appeared on the market soon after and were widely inkjet with UV laser method, due to the contraction
distributed21,22). However, if low-cost printers are during polymerization of the monomer by the laser,
compared to printers for professional use, it is clear that the dimension of the molded crown tended to become
the former is inferior in terms of precision. With respect smaller than the designed value. PJ cured the thin
to the printers used in this study, the CX thermo-fusion layer of the jetted monomer droplet, so polymerization
type and B9 digital light processing stereo-lithograph shrinkage was also present, but the influence of the
type 3D printers are regarded as relatively low-cost contraction due to the site was considered to be smaller.
printers, while the DW laser stereo-lithograph type of DW adopted a galvano scanning system for laser
3D printer and the PJ multi-jet modeling device utilizing irradiation, so the difference due to the site was reduced,
a UV laser are regarded as professional devices. contrary to the case of B9. From the viewpoint of extra-
The lamination pitch of CX was 0.1 mm, which is coronal restoration, when the crown was molded by a 1%
quite large compared to that of other printers used in increase of the prototype using PJ or DW, the inner
this study, therefore, the striped pattern contour caused diameter between both sides was shaped approximately
by laminations was clearly observed in the crowns made 70 μm larger in inside diameter on both sides.
by CX. The lamination pitch of B9 was 25 µm20) and was Considering the thickness of the cement component,
regarded as being relatively large, but the appearance of the molded product obtained an excellent fit in terms of
the crown was relatively smooth because of the molding compatibility.
method performed by lifting a product from a monomeric The stacking direction of the printer was coincident
solution. The lamination pitch of DW was the smallest at with the crown depth; the accuracy in depth was
10 µm23), so the crown showed a very smooth appearance particularly susceptible to the performance of each
when created with the molding method utilizing a printer. The depth of the crown molded by thermo-fusion
stereo-lithograph device with laser light in a monomer printer CX became much smaller than the designed
liquid. Because PJ uses multi-jet modeling technology, value because of the large stacking pitch of 0.1 mm; it
it was not possible to directly compare the stacking pitch also became much smaller in B9. The depth of the crown
for the other methods of 3D printers. Although it was molded by PJ and DW was almost equal to the designed
Dent Mater J 2016; 35(2): 250–256 255
value; therefore, the thickness of a sufficient cement printers except B9 became smaller than the
layer depth could be obtained without any scaling. designed value at any magnification. In particular,
With respect to the type of printers, although CX the crown created by CX showed a much smaller
showed the best accuracy in terms of the outer diameter, inner diameter than the designed one.
i.e., less than 50 μm, CX showed the worst accuracy in 3. In any of the enlargement ratios, although the
terms of the inner diameter and the depth, as shown in depth of the crown created by CX and B9 tended
Table 3. Because PJ and DW showed the best accuracy, to decrease considerably, that created by PJ
i.e., less than 60 μm, in terms of the inner diameter and and DW inversely showed a slightly increasing
depth, by understanding the characteristics of these tendency.
printers, it is possible to prepare excellent compatible 4. With respect to the deviation from the designed
prostheses using these printers. value, CX showed the best accuracy in terms
Regarding the horizontal surface roughness, as of the outer diameter and the worst accuracy
a significant difference was not observed among the in terms of the inner diameter and depth. PJ
printers; however, in the comparison with CX, uniform and DW showed the best accuracy for the inner
polymerization seemed to be induced, and then a diameter and depth.
relatively smooth surface was obtained by DW, a stereo- 5. The surface roughness of the crown created by
lithograph printer, and PJ, a multi-jet modeling printer. CX was the largest, and the roughness along
The surface roughness of the axial (vertical) direction the tooth axial direction was greater than that
indicated the largest value in CX and was regarded to along the horizontal direction for B9 and PJ.
directly reflect the magnitude of the lamination pitch. The roughness along the tooth axis of the crown
As a pattern for the dental crown, the roughness was so created by DW was the smallest and that along
significantly large that preprocessing such as polishing the horizontal direction of the crown created by
prior to investing would be required for practical use. PJ was the smallest.
Compared to the vertical surface roughness of the
crowns made by B9 and PJ, a considerably small value ACKNOWLEDGMENTS
was observed in modeling with DW, due to the direct
reflection of the size of the stacking pitch. We would like to thank Mr. Noriyuki OTAKE of 3D
From the results of this study, as for CX, which Solution Group, Department of Dental Solution,
is a thermo-fusion 3D printer, although the surface Toyotsu Machinery for assistance with the 3D printing.
roughness and dimensional accuracy seemed to be We also express our sincere appreciation to the staff of
problematic in terms of oral prosthesis applications, Department of Dental Materials Science, School of Life
the relative dimensional accuracy could be improved Dentistry at Tokyo, The Nippon Dental University for
with an increase in the size of the products, as in the their invaluable support of this study.
jaw model. Dental applications of this type of 3D printer
could be made possible by data processing, considering REFERENCES
the compatibility of the abutment. However, current
3D printers utilizing stereo-lithography, regardless of 1) Nayar S, Bhuminathan S, Bhat WM. Rapid prototyping and
whether they are of the DLP projector or galvano laser stereolithography in dentistry. J Pharm Bioallied Sci 2015; 7:
216-219.
type or the multi-jet method, were believed to provide 2) Lima JM, Anami LC, Araujo RM, Pavanelli CA. Removable
sufficient accuracy for dental applications by modifying partial dentures: use of rapid prototyping. J Prosthodont
some of the modeling data. Pattern casting has already 2014; 23: 588-591.
been clinically applied in laser cutting using CAD/CAM 3) Saleh WK, Ariffin E, Sherriff M, Bister D. Accuracy and
technology. Additive manufacturing technologies, such reproducibility of linear measurements of resin, plaster,
as 3D printers, have a definite advantage in terms of digital and printed study-models. J Orthod 2015; DOI
10.1179/1465313315Y.0000000016.
their effective use of raw materials. The development
4) Lauvahutanon S, Takahashi H, Oki M, Arksornnukit M,
of high-accuracy and low-cost instruments in the near Kanehira M, Finger WJ. In vitro evaluation of the wear
future could be further applied to the dental industry. resistance of composite resin blocks for CAD/CAM. Dent
Mater J 2015; 34: 495-502.
5) Lauvahutanon S, Takahashi H, Shinozawa M, Iwasaki N,
CONCLUSIONS Asakawa Y, Oki M, Finger WJ, Arksornnukit M. Mechanical
properties of composite resin blocks for CAD/CAM. Dent
Four 3D printers differing in their molding processes
Mater J 2014; 33: 705-710.
were employed to create resin patterns of the model 6) Tomita S, Shin-ya A, Gomi H, Shin-ya A, Yokoyama D.
crown, and the following conclusions were drawn. Machining accuracy of crowns by CAD/CAM system using
1. The outer diameter of the created crown was TCP/IP: influence of restorative material and scanning
smaller than the designed value in most condition. Dent Mater J 2007; 26: 549-560.
conditions, especially that created by B9, which 7) Taira Y, Odatsu T. Sawase T. Effects of a fluoride etchant
showed the smallest value. Some crowns created and a phosphate primer on bonding of veneering composite
to Ti-6Al-4V alloy for CAD/CAM restorations. J Prosthodont
by CX showed greater values in the outer diameter
Res 2013; 57: 30-35.
than the designed ones. 8) Nakamura K, Harada A, Inagaki R, Kanno T, Niwano Y,
2. The inner diameter of the created crown by the Milleding P, Örtengren U. Fracture resistance of monolithic
256 Dent Mater J 2016; 35(2): 250–256
zirconia molar crowns with reduced thickness. Acta Odontol Mathematical and Computer Modelling 2003; 38: 945-960.
Scand 2015; 73: 602-608. 16) Chen Y H, Ng C T, Wang Y Z. Generation of an STL file from
9) Sedda M, Vichi A, Carrabba M, Capperucci A, Louca C, Ferrari 3D measurement data with user-controlled data reduction.
M. Influence of coloring procedure on flexural resistance of Int J Adv Manuf Technol 1999; 15: 127-131.
zirconia blocks. J Prosthet Dent 2015; 114: 98-102. 17) Horvath J. Mastering 3D printing. New York: Apress
10) Vojdani M, Torabi K, Farjood E, Khaledi A. Comparison the (Springer); 2015. p. 51-52.
marginal and internal fit of metal copings cast from wax 18) Starosolski ZA, Kan JH, Rosenfeld SD, Krishnamurthy
patterns fabricated by CAD/CAM and conventional wax up R, Annapragada A. Application of 3-D printing (rapid
techniques. J Dent Shiraz Univ Med Sci 2013; 14: 118-129. prototyping) for creating physical models of pediatric
11) Torabi K, Farjood E, Hamedani S. Rapid prototyping orthopedic disorders. Pediatr Radiol 2014; 44: 216-221.
technologies and their applications in prosthodontics, a 19) 3D Systems: CubeXTM Printer user guide. 2012. 44-46.
review of literature. J Dent Shiraz Univ Med Sci 2015; 16: 20) Hotproceed: B9Creator Japanese manual. 2013. 34-35.
1-9. 21) Muita K, Westerlund M, Rajala R. The evolution of rapid
12) van Noort R. The future of dental devices is digital. Dent production: How to adopt novel manufacturing technology.
Mater 2012; 28: 3-12. International Federation Automatic Control —Papers On
13) Bae EJ, Kim HY, Kim WC, Kim JH. In vitro evaluation of Line 2015; 48:032-037.
the bond strength between various ceramics and cobalt- 22) Galantucci L M, Bodi I, Kacani J, Lavecchia F. Analysis of
chromium alloy fabricated by selective laser sintering. J Adv dimensional performance for a 3D open-source printer based
Prosthodont 2015; 7: 312-316. on fused deposition modeling technique. Procedia CIRP 2015;
14) Sohmura T. The present condition of the dental scanner and 28: 82-87.
3D printer. J J Acad Digit Dent 2014; 4: 2-11. 23) Miyasaka T. Dental models and crowns manufactured by 3D
15) Szilvśi-Nagy M, Matyasi GY. Analysis of STL files. printer. J J Dent Mater 2014; 33: 281-284.