Documente Academic
Documente Profesional
Documente Cultură
1 /1
PERFORMANCE
RANDHART 1457 CURVE
TEL: (011) 617-0700 REFERENCE
E-MAIL: pumpsales@warman.co.za
TYPE
IMPELLER B1127 LINER
WPA
AH VANES TYPE MAT’L VANE O MAT’L
151B01
5 OPEN METAL 152 METAL
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD Reprinted
GLAND SEAL PUMP February 2000
WE RESERVE THE RIGHT TO MODIFY OR DELETE
IMPELLERS WITHOUT PRIOR NOTICE POWER CONSUMED MAY INCREASE BY 5% WITH CENTRIFUGAL SEAL
MIN PASSAGE SIZE
* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum frame size that can be fitted to any particular bearing assembly.
100
4400
30% 40% 45%
90
50%
4200
80
4000
56%
3800
70
3600
H (m)
60
50%
3400
45%
50 3200
3000
40
2800
0
0 2 4 6 8 10 12 14 16
Q (l/sec)
20
16
NPSH (m)
4400
12
r/min
0
8
Revision :
1200
r/min
4
0
COMPONENTS DIAGRAM OUTLINE DIMENSIONS VIEW BROCHURE INDEX
* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.
70
3200 20%
30%
r/min 35%
40%
60
3000 45%
50
2800 47%
2600
45%
H (m)
40
2400
40%
2200
30
2000
1400
10
1200
0
0 5 10 15 20 25
Q (l/sec)
20
NPSH (m)
16
12
3200
r/min
0
8
Revision :
4
1200
r/min
0
COMPONENTS DIAGRAM OUTLINE DIMENSIONS VIEW BROCHURE INDEX
* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.
100
90 3100 40%
r/min 50%
55%
60%
80
2900
65%
67%
70
2700
65%
60 2500 60%
H (m)
2300
50
2100
40
1500
20
1300
1100
10
0
0 5 10 15 20 25 30 35 40 45 50
Q (l/sec)
16
3100
NPSH (m)
r/min
12
0
8
Revision :
4
1100
r/min
0
COMPONENTS DIAGRAM OUTLINE DIMENSIONS VIEW BROCHURE INDEX
* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.
100
60
2600
H (m)
2400
50
2200
40
2000
1600
20
1400
1200
10
0
0 5 10 15 20 25 30 35 40 45 50
Q (l/sec)
25
3170
NPSH (m)
20
r/min
15
0
10
Revision :
5 1200
r/min
0
COMPONENTS DIAGRAM OUTLINE DIMENSIONS VIEW BROCHURE INDEX
* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.
90
70
2400 68%
60
65%
2200
H (m)
50
2000
40
1800
1400
20
1200
1000
10
0 90
0 10 20 30 40 50 60 70 80
Q (l/sec)
20
16
NPSH (m)
2750
12
r/min
0
8
Revision :
4 1000
r/min
0
COMPONENTS DIAGRAM OUTLINE DIMENSIONS VIEW BROCHURE INDEX
* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.
100
2750 30% 40%
50%
r/min 60%
68%
90
2600
72%
80 74.5%
2400 72%
70
2200
60
H (m)
2000
50
1800
40
20 1200
1000
10
0
0 10 20 30 40 50 60 70 80 90
Q (l/sec)
20
NPSH (m)
16
2750
12 r/min
0
8
Revision :
4 1000
r/min
0
COMPONENTS DIAGRAM OUTLINE DIMENSIONS VIEW BROCHURE INDEX
* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.
100
77%
1600
70
75%
1500
60
H (m)
1400
50
1300
1200
40
1100
10
0
0 20 40 60 80 100 120 140 160 180
Q (l/sec)
15
1800
NPSH (m)
r/min
12
9
0
Revision :
3 800
r/min
0
COMPONENTS DIAGRAM OUTLINE DIMENSIONS VIEW BROCHURE INDEX
* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.
90
1600 70%
60
1500 68%
H (m)
1400
50
1300
40
1200
900
20
800
10
Q (l/sec)
16
1800
NPSH (m)
r/min
12
8
0
Revision :
4
800
r/min
0
COMPONENTS DIAGRAM OUTLINE DIMENSIONS VIEW BROCHURE INDEX
* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.
90
40% 50%
1300 20% 60%
80 r/min 65%
70%
70 1200
72%
70%
60
1100
H (m)
50
1000
40 900
800
700
20
600
500
10
0
0 50 100 150 200 250 300
Q (l/sec)
15
1300
NPSH (m)
12
r/min
9
0
6
Revision :
3
500
r/min
0
COMPONENTS DIAGRAM OUTLINE DIMENSIONS VIEW BROCHURE INDEX
* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.
100
80 1200
75%
70
1100
60
70%
H (m)
1000
50
900
40
800
20
600
500
10
0
0 50 100 150 200 250 300 350 400
Q (l/sec)
20
NPSH (m)
16 1300
r/min
12
0
Revision :
4 500
r/min
0
COMPONENTS DIAGRAM OUTLINE DIMENSIONS VIEW BROCHURE INDEX
* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.
100
1000 40%
90
r/min 60%
65%
70%
80
71%
900
70
70%
65%
60 800
H (m)
50
700
40
500
20
400
10
0
0 100 200 300 400 500 600
Q (l/sec)
25
NPSH (m)
20
1000
15 r/min
0
10
Revision :
400
5
r/min
0
COMPONENTS DIAGRAM OUTLINE DIMENSIONS VIEW BROCHURE INDEX
* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.
90
900 40%
60%
r/min 70%
80
75%
78%
70
800 80%
60
78%
700
H (m)
50
40 600
20
400
10
300
0
0 100 200 300 400 500 600
Q (l/sec)
15
NPSH (m)
12
900
9
r/min
0
6
Revision :
3
300
r/min
0
COMPONENTS DIAGRAM OUTLINE DIMENSIONS VIEW BROCHURE INDEX
* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.
100
70
75%
600
70%
60
H (m)
550
50
500
40
450
350
20
300
10
0
0 200 400 600 800 1000 1200
Q (l/sec)
25
700
NPSH (m)
20 r/min
15
0
10
Revision :
5 300
r/min
0
COMPONENTS DIAGRAM OUTLINE DIMENSIONS VIEW BROCHURE INDEX
Pump Curves
Series A
Type AH
Metal Lined Pumps
Pump Curves
Series A
Type AH
Metal Lined Pumps
14/12 - AH METAL - HE
* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.
70
82%
500
50
450 80%
H (m)
40
400
30
350
250
10
0
0 200 400 600 800 1000 1200
Q (l/sec)
16
NPSH (m)
12
550
r/min
0
8
Revision :
4
250
r/min
0