The document provides design details for an I-section beam with a 2m cantilever span subjected to a 45kN/m uniform distributed load and 0 kN point load at the free end. The section properties and material properties are given. The beam is designed to resist bending, shear, and deflection. Checks are also performed for web buckling and bearing at the support. The design is found to be adequate in all checks.
The document provides design details for an I-section beam with a 2m cantilever span subjected to a 45kN/m uniform distributed load and 0 kN point load at the free end. The section properties and material properties are given. The beam is designed to resist bending, shear, and deflection. Checks are also performed for web buckling and bearing at the support. The design is found to be adequate in all checks.
The document provides design details for an I-section beam with a 2m cantilever span subjected to a 45kN/m uniform distributed load and 0 kN point load at the free end. The section properties and material properties are given. The beam is designed to resist bending, shear, and deflection. Checks are also performed for web buckling and bearing at the support. The design is found to be adequate in all checks.
Span of the beam : 2.00 m (Cantilever) Section Properties; 2 ƒy = 250 A: 13200.0 mm rzz : 221.72 mm Acting Loads: h: 550.0 mm ryy : 37.27 mm 3 Factored UDL on beam : 45.00kN/m b: 190.0 mm Zez : 2359600.00 mm 3 Factored point load @ free end : 0.00 kN tf : 19.3 mm Zey : 193052.63 mm 3 Factored moment @ free end : 0.00 kNm tw : 11.2 mm Zpz : 2712000.00 mm 4 3 Total Factored design Moment: 93.11 kNm Izz : 648890000.0 mm Zpy : 328000.00 mm 4 Total Factored design Shear: 93.11 kN Iyy : 18340000.0 mm Weight: 1.04 kN/m Considered Section; I Section ISMB550 Ɛ: 1 b/tf : 4.922 Section is Plastic d : 475.4 mm < 9.400 Plastic 3 Zp Provided : 2712000.00 mm d/tw : 42.446 3 Zp Required : 409677.84 mm O.K. < 84.000 Plastic 2.Design: A) Bending : B) Shear : C) Deflection check : Capacity of the section = βb Zp ƒy / ɣm0 < 1.5 Ze ƒy / ɣm0 Design Strength Vd : 808.29 kN i. Due to UDL : 0.48 = 616.364 < 804.409 0.6Vd : 484.97 kN >93.11 ii. Due to Point Load: 0.00 where; βb = 1 Total : 0.48 mm ɣm0 = 1.1 Allow. Deflection: 11.11 mm O.K. O.K. O.K. 3.Check for web buckling and bearing @ support: A) Web buckling: B) Web bearing: Width of stiff bearing length (width of Bearing resistance = (b1+n2) x tw x ƒy / ɣmo End Joint support) : 100.00 mm = 491.91 kN >93.11 kN Ieff of web: 11707.73 mm4 O.K. 2 Aeff of web: 1120 mm where, r= 3.233 mm b1 = 100.00 mm KL/r=0.7d/r = 102.93 n2 = 93.25 mm So, ƒcd = 103.21 Ab = 4200 So, Buckling resistance = ƒcd x Ab = 433.49 kN >93.11 kN O.K.