Documente Academic
Documente Profesional
Documente Cultură
TDH
9 P
450
bar(g) kW
8 400
TDH Seawater
4 MCSF 200
3 150
Admissible working range
Discharge Pressure :
2 Draft level + 30 m 100
1.75
Draft level + 25 m
Pp Seawater
1 50
Draft level + 9 m
0 0
0 50 100 150 200 250 300 350 400 450 m³/h
500
100 50
70 35
60 30
50 25
40 20
30 15
20 10
The submergence is measured from the
NPSHR upper side of the suction casing inlet.
10 5
Submergence
0 0
0 50 100 150 200 250 300 350 400 450 500
m³/h
Curves are approximate. Pump is guaranteed for conditions stated above.
Test is performed with fresh water at a temperature of approx. 20°C.
Flowserve Hamburg GmbH - P.O. Box 70 13 20 - D-22013 Hamburg Version 17.4
Document Name Pump Performance Data (Short List)
Pump / Motor Type QT14EMM-3a + MI10-600-4
Customer Toan Thang Pump Curve Number S 54 812 Rev. B
Flowserve SIHI Inquiry Number HMB_PROP-0930/C/0003 Application Engineer EG
Germany GmbH Test tolerance EN ISO 9906: 1999, Cl. 2 Date 20.12.2017
Operating Point
Capacity 240 m³/h
Total Head 5,6 bar(g)
Efficiency 79,3 %
Rated Power 47,1 kW
NPSHR 2,5 m
Maxima
H0 6,6 bar(g)
Efficiency opt. 81,5 %
Max. Power @ Rated Impeller 57,3 kW at Q = 388,1 m³/h
Working Range
Qopt 290 m³/h at H = 5,1 bar(g)
Qmin f-Qmin = 0,5 145 m³/h at H = 6 bar(g)
Qmax, f-Qmax = 1,3 377 m³/h at H = 4 bar(g)
Rated Data
Percent of the Rated Capacity 100% 110% 125%
Capacity, m³/h 240 264,00 300,00
Total Head, bar(g) 5,6 5,42 5,08
Efficiency, % 79,3 80,87 81,45
Rated Power, kW 47,1 49,1 52,1
NPSHR , m 2,48 2,50 2,57
Min Required Submergence, m 0,6 * 0,6 0,6
MCSF - MINIMUM CONTINUOUNS STABLE FLOW * The submergence is measured from the upper side of the suction casing inlet.
BEP - BEST EFFICIENCY POINT
NPSH - NET POSITIVE SUCTION HEAD
Rated - OPERATING POINT
Flowserve Hamburg GmbH - P.O. Box 70 13 20 - D-22013 Hamburg Version 17.4
Document Name Total Head Calculation
Pump / Motor Type QT14EMM-3a + MI10-600-4
Customer Toan Thang Pump Curve Number S 54 812 Rev. B
Flowserve SIHI Inquiry Number HMB_PROP-0930/C/0003 Application Engineer EG
Germany GmbH Test tolerance EN ISO 9906: 1999, Cl. 2 Date 20.12.2017
DISCHARGE
PRESSURE 1,9 bar(g)
DISCHARGE
LEVEL
44,5 m
Operation Conditions
T.O.F. OF EL
Medium : Seawater 43,7 m
Density of medium : 1025 kg/m³
Viscosity of medium : 0,85 cP
H geo
Well / Caisson
Well / Caisson ID : 558 mm L
PUMP
∑ Sum Pressure Losses : 1,365 m
Velocity Head : 0,230 m
Note 1: The sketch above may not reflect actual pump configuration!
Note 2: To avoid cavitation and air suction it might be necessary to install the unit deeper!