Electric Boilers

2
TER 1

3
9

8 5

6
7

1. Control panel 6. Element supply contactors


2. Power cable entry position 7. Stove enamelled metal casing
3. Power cable connections 8. Heating elements
4. Control circuit terminals 9. Rigid polyurethane foam
5. Power stage delay timer insulation

Product Description

• Floor standing high output electric boiler Typical Installation


• Steel heating body and removable stainless Three TER boilers providing full heating and hot water
steel heating elements capabilities in conjunction with a Jumbo 1000 hot water
• Six standard models of 57.6 to 259 kW storage tank.
• Four power stages – controlled by a stage delay timer
• Can easily be de-rated to provide less output if required
• Fully wired power and control circuits
• 50mm rigid polyurethane foam insulation
• Stove enamelled casing
• Control panel including thermostats, thermometer,
indicators and on/off switch
• Very little maintenance required
• Can also be used in multiple boiler installations
TER

35
Technical Specifications

Maximum Operating Pressure


Primary: 4 bar

Factory Test Pressure


Primary: 6 bar

Maximum Operating Temperature


90°C

Rear Front Right Hand Side

TER 57 TER 86 TER 115 TER 144 TER 201 TER 259

Code 00080401 00080801 00081201 00081601 00079101 00079901


Maximum output kW 57.6 86.4 115.2 144 201.6 259.2
Nominal supply V 3 x 400 + N
Nominal supply (total) amps 250.5 376 501 626 876.5 1127
Nominal supply (per phase) amps 83.5 125.3 167 209 292 376
Dual heating elements * # 12 18 24 30 42 54
Total capacity L 155 155 155 155 250 250
Primary connection (female BSP) Ø 2" 2" 2" 2" DN100 DN100
Dimensions A mm 80 80 80 80 80 80
B mm 124 124 124 124 190 190
C mm 1134 1134 1134 1134 1060 1060
D mm 130 130 130 130 197 197
E mm 610 610 610 610 752 752
F mm 1380 1380 1380 1380 1380 1380
G mm 610 610 610 610 752 752
Weight empty Kg 102 102 102 102 195 195
Weight full Kg 257 257 257 257 545 545

* A dual element consists of two elements on a single flange, with a combined output of 4.8 kW at 230 volts

1 2 3 4 5 6 7 8 9

Control Panel

1. Thermometer 5. 3rd stage indicator


2. On/off switch 6. 4th stage indicator
3. 1st stage indicator 7. High temperature overheat indicator
4. 2nd stage indicator 8. Manual reset high limit thermostat
9. Control thermostat